What Happens When an Induction Rotor Reaches Synchronous Speed?
What happens when an induction motor's rotor catches the rotating magnetic field? Explore why induced rotor current and electromagnetic torque fall to zero at synchronous speed, how the machine behaves above that speed, and why synchronous motors work differently.
An eight-pole induction motor connected to a 50 Hz supply has a rotating magnetic field travelling at 750 rpm. Imagine that an external drive accelerates the rotor until it also reaches exactly 750 rpm.
What happens next?
In steady state, the rotor stops experiencing changing magnetic flux from the rotating stator field. The induced rotor EMF falls to zero, the rotor current disappears, and the electromagnetic torque produced by induction falls to zero.
The motor has effectively lost the mechanism that allows it to drive its load. It can be held at synchronous speed by an external mechanical drive, but it cannot produce sustained induction torque at that speed.
This is not a minor technical detail. It explains why an induction motor normally runs slightly below synchronous speed, why it can become a generator when driven faster than synchronous speed, and why a different type of motor can operate at exactly synchronous speed.
01Why reaching synchronous speed removes induction torque
Start by separating two things that rotate inside an induction motor:
- The rotating magnetic field, produced by the stator windings.
- The physical rotor, which carries conducting bars connected into closed electrical circuits.
The stator itself does not rotate. Its magnetic field does.
As this field moves past the rotor conductors, the magnetic flux through the rotor circuits changes. Faraday’s law tells us that this changing flux induces an electromotive force (EMF). Because the rotor circuits are closed, an electric current flows.
The current then experiences a magnetic force in the stator’s field. The resulting forces produce a turning effect, or torque, on the rotor.
Now consider what changes when the rotor catches the magnetic field.
Imagine marking one rotor bar and following it around the motor. While the magnetic field rotates faster than the rotor, the field pattern moves past that bar. The magnetic flux experienced by the bar’s conducting circuit changes.
But suppose the rotor and field rotate at exactly the same speed.
The bar now remains beneath the same part of the magnetic-field pattern. There is no continuing relative motion between the field pattern and the rotor.
A useful way to picture this is to imagine a pattern of alternating stripes moving around a circular drum. If the drum and the pattern rotate together, a mark on the drum stays beneath the same stripe.
The analogy breaks down because a magnetic field is not a physical pattern painted onto a surface. Actual induction depends on changing magnetic flux, not physical contact.
At synchronous speed, the consequences follow in sequence:
- The rotating field no longer moves relative to the rotor conductors.
- The fundamental magnetic flux through the rotor circuits stops changing.
- No continuing rotor EMF is induced.
- The steady-state induced rotor current falls to zero.
- The magnetic forces responsible for induction torque disappear.
The key distinction is that the magnetic field is still rotating relative to the stationary stator. It is simply no longer rotating relative to the rotor.
For a fuller explanation of how the three-phase stator produces its rotating field, see AC Induction Motors: Rotating Fields, Rotor Currents and Slip.
02What does zero slip actually mean?
The speed of the rotating magnetic field is called the synchronous speed.
It depends on the AC supply frequency and the number of magnetic poles in the stator:
\[ n_s=\frac{120f}{P} \]
where:
- \(n_s\) is synchronous speed, measured in revolutions per minute (rpm).
- \(f\) is the supply frequency, measured in hertz (Hz).
- \(P\) is the total number of magnetic poles.
For an eight-pole motor connected to a 50 Hz supply:
\[ n_s=\frac{120(50)}{8} =750\text{ rpm} \]
The rotor speed is represented by \(n_r\).
The difference between these speeds determines how quickly the rotating magnetic field moves relative to the rotor.
This difference is measured using slip:
\[ s=\frac{n_s-n_r}{n_s} \]
Slip is dimensionless. Multiply it by 100 to express it as a percentage.
For this explanation, take the direction of the rotating stator field as positive. Positive slip indicates normal motoring operation, while negative slip indicates operation above synchronous speed.
The three important conditions are:
| Rotor condition | Slip | Physical result |
|---|---|---|
| \(n_r<n_s\) | Positive | Rotor current is induced and the machine produces forward motor torque. |
| \(n_r=n_s\) | Zero | No steady-state rotor induction or induction torque. |
| \(n_r>n_s\) | Negative | Rotor induction reverses and electromagnetic torque opposes the rotor’s rotation. |
There is another useful relationship. The frequency of the induced rotor current is:
\[ f_r=|s|f \]
Here, \(f_r\) is the rotor current frequency in hertz. The absolute value is used because frequency is a magnitude, even when slip is negative.
At exactly synchronous speed:
\[ s=0 \]
Therefore:
\[ f_r=0\times f=0\text{ Hz} \]
The rotor no longer experiences an alternating magnetic field at the fundamental slip frequency.
Important: Zero rotor current does not mean zero stator current. The stator still needs magnetising current to establish its magnetic field. Real motors also have electrical and magnetic losses.
03What happens just below, at, and above synchronous speed?
The most useful way to understand synchronous speed is to treat it as a boundary between different operating conditions.
Consider an eight-pole induction machine connected to a 50 Hz supply. Its synchronous speed is 750 rpm.
The following values are illustrative predictions from the idealised induction-machine model, not measurements from a particular motor.
| Rotor speed | Signed slip | Rotor current frequency | Operating condition |
|---|---|---|---|
| 720 rpm | +4% | 2 Hz | Motor |
| 735 rpm | +2% | 1 Hz | Motor |
| 750 rpm | 0% | 0 Hz | Zero steady-state induction torque |
| 765 rpm | -2% | 1 Hz | Generator |
Notice something interesting.
At 720 rpm, the magnetic field overtakes the rotor by 30 rpm. At 765 rpm, the rotor overtakes the magnetic field by 15 rpm.
The direction of relative motion determines the direction of the induced electromagnetic torque.
Below synchronous speed: normal motor operation
When the rotor rotates more slowly than the magnetic field, the field sweeps past the rotor conductors.
This produces an induced EMF and current. Their interaction with the stator magnetic field generates torque in the direction of rotation.
Electrical energy is transferred into mechanical energy.
The rotor must maintain some positive slip to keep producing this torque.
At synchronous speed: zero steady-state induction torque
When the rotor reaches 750 rpm, the relative speed becomes zero.
The fundamental rotating field no longer sweeps past the rotor conductors. No continuing rotor EMF is induced, so the steady-state rotor current and induction torque become zero.
If a mechanical load is still connected, something must supply its required torque. The induction motor cannot provide it at zero slip.
Above synchronous speed: generator operation
Now imagine an external machine driving the rotor at 765 rpm while the stator remains connected to a suitable electrical supply.
The rotor overtakes the rotating magnetic field.
The relative motion reverses, changing the direction of the induced rotor currents. The electromagnetic torque now acts against the rotor’s rotation.
The external mechanical drive must supply energy to overcome this opposing torque.
The machine can therefore transfer mechanical energy into electrical energy. It is operating as an induction generator.
A grid-connected induction generator also needs magnetising current to establish its magnetic field. The grid supplies this reactive power while the machine can return real electrical power.
This is an important distinction: an induction machine does not stop being an induction machine when it becomes a generator. The same electromagnetic mechanism operates with the opposite sign of slip.
04How could an experiment test the prediction?
A normal unloaded induction motor is not the best apparatus for investigating exactly what happens at synchronous speed.
Why?
Even without an external load, a real motor experiences friction in its bearings and resistance from moving air. These losses require a small amount of electromagnetic torque.
The motor therefore settles slightly below synchronous speed, maintaining the small positive slip needed to overcome its losses.
A more useful experiment would deliberately control the rotor speed.
Setting up the apparatus
Consider a proposed experiment using a wound-rotor induction machine.
The apparatus consists of:
- A three-phase AC supply connected to the stationary stator windings.
- A wound rotor positioned inside the stator.
- Slip rings connecting the rotor windings to a closed circuit containing a current sensor.
- A variable-speed dynamometer coupled to the rotor shaft.
- An optical encoder measuring the rotor’s rotational speed.
- A torque transducer measuring the mechanical torque at the shaft.
- A power analyser monitoring the stator’s electrical input.
The wound-rotor design is useful because its slip rings allow the rotor current to be measured directly. A conventional squirrel-cage rotor does not provide these accessible electrical connections.
What should the original experiment show?
Start with the rotor running below synchronous speed.
The encoder measures its speed, while the current sensor measures the induced rotor current.
The dynamometer gradually increases the rotor speed towards synchronous speed.
The induction model predicts that:
- The relative motion between the field and rotor decreases.
- The induced rotor EMF decreases.
- The rotor current decreases.
- The electromagnetic torque approaches zero.
If the rotor is held at exactly synchronous speed, the steady-state induced rotor current should approach zero.
This is the critical prediction.
Why a basic experiment can give an incomplete answer
Suppose the experiment simply removes the external mechanical load and measures the final rotor speed.
The rotor might settle at 744 rpm rather than 750 rpm.
A student could conclude that the rotor can never reach synchronous speed.
But that conclusion confuses two different situations.
In the first situation, the motor is running freely and must overcome its own mechanical losses. It needs some torque, so it needs some slip.
In the second situation, an external dynamometer forces the rotor to synchronous speed. The dynamometer supplies whatever mechanical torque is needed to overcome the motor’s losses.
The revised experiment directly tests the zero-slip condition rather than assuming an unloaded motor will naturally reach it.
There is also an important measurement issue. A torque transducer can measure mechanical torque associated with friction and windage as well as electromagnetic torque. These contributions must be accounted for when interpreting the result.
The rotor current measurement provides a more direct test of the induction mechanism.
05Worked examples
Worked example: How close is the rotor to synchronous speed?
An eight-pole induction motor operates on a 50 Hz supply. Its rotor rotates at 747 rpm.
Calculate:
(a) The synchronous speed.
(b) The percentage slip.
(c) The frequency of the induced rotor current.
(d) What happens to the steady-state induction torque if the rotor is externally held at 750 rpm?
Step 1
We know:
- \(f=50\text{ Hz}\)
- \(P=8\)
Using:
\[ n_s=\frac{120f}{P} \]
\[ n_s=\frac{120(50)}{8} \]
\[ n_s=750\text{ rpm} \]
Step 2
The rotor is turning at 747 rpm, so:
\[ s=\frac{750-747}{750} \]
\[ s=\frac{3}{750}=0.004 \]
Convert to a percentage:
\[ s=0.004\times100 \]
\[ s=0.40\% \]
Step 3
Use:
\[ f_r=sf \]
Substitute:
\[ f_r=0.004\times50 \]
\[ f_r=0.20\text{ Hz} \]
The rotor experiences a relatively low-frequency induced current because its speed is already close to synchronous speed.
Step 4
If the rotor is held at exactly 750 rpm:
\[ s=\frac{750-750}{750}=0 \]
Therefore:
\[ f_r=0\text{ Hz} \]
In steady state, the fundamental induction mechanism produces no rotor current and no electromagnetic torque.
The external dynamometer must supply any torque needed to overcome mechanical losses.
Worked example: An induction motor becomes a generator
A six-pole induction machine is connected to a 50 Hz electrical grid. An external turbine drives its rotor at 1025 rpm in the same direction as the stator’s rotating magnetic field.
Calculate:
(a) The synchronous speed.
(b) The signed percentage slip.
(c) The rotor current frequency.
(d) Whether the machine is operating as a motor or generator, and the direction of its electromagnetic torque.
Assume the grid continues to provide the magnetising current required by the machine.
Step 1
The machine has six poles and operates at 50 Hz.
\[ n_s=\frac{120f}{P} \]
\[ n_s=\frac{120(50)}{6} \]
\[ n_s=1000\text{ rpm} \]
Step 2
The rotor is rotating faster than the stator field.
\[ s=\frac{n_s-n_r}{n_s} \]
Substitute:
\[ s=\frac{1000-1025}{1000} \]
\[ s=-0.025 \]
Therefore:
\[ s=-2.5\% \]
The negative sign is important. It tells us that the rotor is overtaking the rotating magnetic field.
Step 3
Use the magnitude of slip:
\[ f_r=|s|f \]
\[ f_r=0.025\times50 \]
\[ f_r=1.25\text{ Hz} \]
Step 4
The machine is operating as an induction generator.
Because the rotor is moving faster than the rotating magnetic field, the induced electromagnetic torque opposes the rotor’s clockwise rotation.
The turbine must supply mechanical energy to overcome this opposing torque.
The energy conversion is:
\[ \text{Mechanical energy} \rightarrow \text{Electrical energy} \]
The machine can therefore return real electrical power to the grid.
The important point is that negative slip does not mean induction has stopped. It means the relative motion has reversed.
06Why can a synchronous motor operate at synchronous speed?
Here is a useful comparison.
If zero relative motion removes induction torque, how can a synchronous motor operate at exactly synchronous speed while still producing torque?
The answer is that the two machines use different mechanisms to produce their rotor magnetic fields.
An induction motor relies on current induced in its rotor by the rotating stator field.
A synchronous motor has a rotor magnetic field produced independently, usually by permanent magnets or a DC-excited winding. Synchronous reluctance motors use a different rotor construction that produces torque through magnetic reluctance.
This difference changes everything.
In a synchronous motor, the rotor’s magnetic field locks into synchronism with the stator’s rotating magnetic field.
The two fields rotate at the same speed, but their magnetic axes can remain separated by a fixed angle.
This angle is called the torque angle.
The interaction between the two magnetic fields produces torque even though there is no continuing relative rotation between them.
Compare the mechanisms:
| Feature | Induction motor | Synchronous motor |
|---|---|---|
| Rotor magnetic field | Produced by induced rotor current | Produced independently or through rotor reluctance |
| How torque is produced | Interaction between stator field and induced rotor currents | Interaction between stator and rotor magnetic fields, or reluctance effects |
| Can it produce steady torque at zero slip? | No, not through the fundamental induction mechanism | Yes |
| Normal operating speed | Slightly below synchronous speed | Exactly synchronous speed |
A synchronous motor can therefore produce torque at synchronous speed because it does not rely on slip to induce its rotor current.
This is the misconception to avoid:
Zero slip does not mean every electric motor must produce zero torque. It means an induction motor cannot produce sustained torque through its normal rotor-induction mechanism at zero slip.
07One important qualification: instantaneous versus steady-state behaviour
There is a subtle detail worth understanding before applying the zero-slip rule.
Suppose an induction motor is running at 720 rpm, below its synchronous speed of 750 rpm. Its rotor already contains induced current.
An external drive suddenly accelerates the rotor to 750 rpm.
Does the rotor current disappear instantly?
Not necessarily.
The rotor circuits have resistance and inductance. Inductance prevents an existing current from changing instantaneously.
When the rotor reaches synchronous speed, the continuing induced EMF from the fundamental rotating field becomes zero. However, any current already flowing must decay rather than disappear as an instantaneous step.
During this brief transient, some rotor current and associated electromagnetic torque can remain.
The current eventually decays to zero as electrical energy stored in the rotor’s magnetic field is dissipated through resistance.
This does not contradict the usual HSC explanation.
The standard statement that an induction motor produces zero torque at synchronous speed refers to its steady-state operation, after transient currents have died away.
There are therefore two different statements:
- Immediately after reaching synchronous speed, pre-existing rotor current may still be present.
- After the transient has ended, there is no sustained induced rotor current or induction torque.
Keeping these statements separate makes the physics more accurate.
08Questions and solutions
Question 1
A six-pole induction motor operates on a 50 Hz supply. Its rotor rotates at 970 rpm.
Calculate:
(a) The synchronous speed.
(b) The percentage slip.
(c) The frequency of the induced rotor current.
(d) The steady-state electromagnetic torque produced by induction if the rotor reaches synchronous speed.
Solution 1
The synchronous speed is 1000 rpm, the slip is 3.0%, and the rotor current frequency is 1.5 Hz. At synchronous speed, the steady-state induction torque is zero.
Part (a): Synchronous speed
Use:
\[ n_s=\frac{120f}{P} \]
Substitute:
\[ n_s=\frac{120(50)}{6} \]
\[ n_s=1000\text{ rpm} \]
Part (b): Percentage slip
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1000-970}{1000} \]
\[ s=0.03 \]
Therefore:
\[ s=3.0\% \]
Part (c): Rotor current frequency
\[ f_r=sf \]
\[ f_r=0.03\times50 \]
\[ f_r=1.5\text{ Hz} \]
Part (d): Torque at synchronous speed
At synchronous speed:
\[ n_r=n_s \]
Therefore, slip becomes zero.
There is no continuing change in magnetic flux through the rotor circuits caused by the fundamental rotating field. The induced rotor EMF and steady-state current become zero, removing the mechanism responsible for induction torque.
The tempting prediction is that reaching the field’s speed should maximise motor performance. In fact, it removes the relative motion required to produce torque.
Question 2
An eight-pole induction motor operates on a variable-frequency drive.
Initially, the supply frequency is 50 Hz, and the rotor runs at 735 rpm.
The drive then reduces the supply frequency to 48 Hz. Because of rotational inertia, the rotor speed remains approximately 735 rpm immediately after the change.
Assume the drive reduces its voltage proportionally to maintain approximately constant magnetic flux.
Calculate:
(a) The initial synchronous speed and slip.
(b) The new synchronous speed.
(c) The new signed slip immediately after the frequency change.
(d) The new rotor current frequency.
(e) Explain why the electromagnetic torque changes direction.
Solution 2
The synchronous speed falls from 750 rpm to 720 rpm. The rotor temporarily overtakes the new rotating field, producing negative slip of approximately -2.08%. The rotor current frequency remains 1.0 Hz in magnitude, but the electromagnetic torque reverses direction.
Part (a): Initial operating condition
Initially:
\[ f=50\text{ Hz},\qquad P=8 \]
Calculate synchronous speed:
\[ n_s=\frac{120(50)}{8} =750\text{ rpm} \]
Calculate initial slip:
\[ s=\frac{750-735}{750} \]
\[ s=0.02=2.0\% \]
The machine initially operates as a motor because the rotor is slower than the rotating field.
Part (b): New synchronous speed
The supply frequency decreases to 48 Hz.
\[ n_s=\frac{120(48)}{8} \]
\[ n_s=720\text{ rpm} \]
The important point is that synchronous speed depends on supply frequency and pole number, not directly on rotor speed.
Part (c): New signed slip
The rotor still rotates at approximately 735 rpm.
\[ s=\frac{720-735}{720} \]
\[ s=\frac{-15}{720} \]
\[ s=-0.02083 \]
Therefore:
\[ s=-2.08\% \]
The rotor is now faster than the rotating magnetic field.
Part (d): New rotor current frequency
Use:
\[ f_r=|s|f \]
\[ f_r=0.02083\times48 \]
\[ f_r\approx1.0\text{ Hz} \]
Interestingly, the rotor current frequency has the same magnitude as before the frequency change.
The relative mechanical speed is 15 rpm in both situations, even though the synchronous speed has changed.
Part (e): Direction of torque
Initially, the rotating field overtakes the rotor, so the electromagnetic torque drives the rotor forwards.
After the frequency reduction, the rotor overtakes the rotating field. The relative motion reverses, and the induced rotor currents change accordingly.
The electromagnetic torque now opposes the rotor’s rotation.
The motor temporarily operates in a regenerative braking condition, provided the drive can absorb the returned energy.
The tempting assumption is that reducing the supply frequency simply slows the rotor. The rotor has inertia, so its speed cannot change instantaneously. The rotating field slows first, changing the sign of slip.
Question 3
A six-pole stator is supplied with balanced three-phase AC at 50 Hz.
Two different machines are connected to the same supply:
- Machine A is a squirrel-cage induction motor.
- Machine B is a permanent-magnet synchronous motor.
A dynamometer holds both rotors at exactly 1000 rpm. Each machine is then required to supply a steady mechanical load.
Assume the synchronous motor remains synchronised and operates below its pull-out torque.
(a) Calculate the synchronous speed.
(b) Which machine can produce sustained electromagnetic torque at 1000 rpm?
(c) Explain why the statement “no relative motion means no torque” applies to Machine A but not Machine B.
(d) Describe what happens to the rotor magnetic field of Machine B when its mechanical load increases.
Solution 3
Machine B, the permanent-magnet synchronous motor, can produce sustained torque at 1000 rpm. Machine A cannot produce sustained fundamental induction torque at that speed.
Part (a): Synchronous speed
\[ n_s=\frac{120f}{P} \]
\[ n_s=\frac{120(50)}{6} \]
\[ n_s=1000\text{ rpm} \]
Both rotors are therefore turning at synchronous speed.
Part (b): Which machine produces torque?
Machine B can produce sustained torque.
Machine A cannot produce sustained induction torque because its rotor conductors have no relative motion with the fundamental rotating stator field.
The induced rotor EMF and steady-state rotor current are zero.
Machine B does not depend on this induction mechanism.
Part (c): Explain the difference
Machine A produces torque through induced currents in its squirrel-cage rotor.
Those currents require relative motion between the rotor and rotating magnetic field. At zero slip, the induction mechanism cannot maintain them.
Machine B has permanent magnets that establish a rotor magnetic field independently of relative motion.
The stator field and rotor field rotate together at synchronous speed. Their magnetic axes remain separated by a fixed angle, allowing a sustained turning effect.
The misconception is to assume that every electromagnetic motor requires relative motion to produce torque. That is true for the induction mechanism, but not for the interaction between two independently established magnetic fields.
Part (d): Increasing the load
As the mechanical load increases, the synchronous motor’s torque angle changes.
The rotor remains locked to the rotating magnetic field and continues turning at synchronous speed, provided the required torque stays within the machine’s stable operating range.
The rotor does not need to slow down to induce current.
This is the fundamental difference between synchronous and induction motors.
Question 4
A group of students investigates an eight-pole, 50 Hz wound-rotor induction motor.
The apparatus includes:
- A three-phase supply connected to the stator.
- A rotor circuit connected through slip rings to a current sensor.
- An encoder measuring rotor speed.
- A dynamometer coupled to the shaft.
With no external mechanical load attached, the rotor settles at 744 rpm.
One student concludes:
“The rotor cannot reach 750 rpm because induction motors always need rotor current. Even if we drive the rotor externally, it must keep producing current.”
Evaluate this conclusion.
Your answer must:
(a) Calculate the synchronous speed.
(b) Calculate the slip and rotor current frequency at 744 rpm.
(c) Explain why the rotor settles below synchronous speed even without an external load.
(d) Describe how the experiment should be modified to test the rotor at exactly synchronous speed.
(e) Predict the readings of the rotor current sensor and stator power analyser once steady state is reached at synchronous speed.
Solution 4
The student’s conclusion is incorrect. The motor needs slip to produce sustained induction torque, but an external drive can hold the rotor at synchronous speed. At that speed, the steady-state induced rotor current and induction torque become zero.
Part (a): Synchronous speed
\[ n_s=\frac{120f}{P} \]
\[ n_s=\frac{120(50)}{8} \]
\[ n_s=750\text{ rpm} \]
Part (b): Slip and rotor current frequency
The rotor speed is 744 rpm.
\[ s=\frac{750-744}{750} \]
\[ s=\frac{6}{750} \]
\[ s=0.008=0.8\% \]
Calculate rotor current frequency:
\[ f_r=sf \]
\[ f_r=0.008\times50 \]
\[ f_r=0.4\text{ Hz} \]
The rotor is running slightly below synchronous speed, so a small amount of induction is still occurring.
Part (c): Why does it run below synchronous speed without an external load?
Removing the external load does not remove every opposing force.
The motor still experiences:
- Bearing friction.
- Air resistance and windage.
- Internal mechanical losses.
The motor needs electromagnetic torque to overcome these losses.
It therefore maintains a small positive slip, allowing rotor current to be induced.
The rotor settles at a speed where the electromagnetic torque balances the opposing mechanical losses.
Part (d): Modify the experiment
Connect the dynamometer so that it can actively drive the rotor shaft.
Gradually increase the shaft speed until the encoder reads 750 rpm.
Keep the stator supply frequency at 50 Hz and the pole number unchanged.
Measure the rotor current directly through the slip-ring circuit.
The dynamometer should maintain the speed while the rotor current is allowed to settle.
The experiment must also account for mechanical losses when interpreting the torque transducer’s reading.
Part (e): Expected measurements
Once steady state is reached at 750 rpm:
\[ s=0 \]
The rotor current sensor should indicate zero steady-state induced current from the fundamental rotating field.
The induction torque should also be zero.
However, the stator power analyser will not necessarily indicate zero current or zero electrical input.
The stator still draws magnetising current to establish its rotating magnetic field. Stator copper losses and core losses also remain.
This distinction is essential: zero rotor induction current does not mean the entire motor has become electrically inactive.
Question 5
A four-pole induction motor operates on a 50 Hz supply. Its rotor initially turns at 1470 rpm.
A high-capability dynamometer rapidly accelerates the rotor to exactly 1500 rpm and holds it there.
Assume:
- The stator supply remains connected throughout.
- The rotor circuit has finite resistance and inductance.
- The rotor initially has non-zero induced current.
- The dynamometer maintains the specified speed at each stage.
After the rotor has been held at 1500 rpm long enough for the initial rotor current to decay, the dynamometer increases its speed to 1512 rpm.
Answer the following:
(a) Calculate the synchronous speed and initial slip.
(b) Immediately after the rotor first reaches 1500 rpm, should the rotor current be expected to disappear instantaneously? Explain.
(c) Describe the long-term rotor current and electromagnetic torque while the rotor is held at 1500 rpm.
(d) Calculate the signed slip and rotor current frequency when the dynamometer increases the rotor speed to 1512 rpm.
(e) Explain why the electromagnetic torque changes direction, and identify the energy conversion occurring at 1512 rpm.
Solution 5
The rotor current does not necessarily disappear instantaneously at 1500 rpm. Any current already flowing must decay because of rotor inductance and resistance. After the transient, the steady-state induction torque becomes zero. At 1512 rpm, the machine develops negative slip and operates as an induction generator.
Part (a): Synchronous speed and initial slip
Calculate synchronous speed:
\[ n_s=\frac{120f}{P} \]
\[ n_s=\frac{120(50)}{4} \]
\[ n_s=1500\text{ rpm} \]
Initially, the rotor turns at 1470 rpm.
Therefore:
\[ s=\frac{1500-1470}{1500} \]
\[ s=\frac{30}{1500} \]
\[ s=0.02=2.0\% \]
The motor initially operates with positive slip and produces forward electromagnetic torque.
Part (b): What happens immediately at 1500 rpm?
The induced rotor EMF from the fundamental rotating field becomes zero when the rotor reaches synchronous speed.
However, the rotor already contains induced current.
The rotor circuit has inductance, which means its current cannot change instantaneously. The existing current must decay through the resistance of the rotor conductors.
Therefore, the current does not necessarily fall to zero at the exact instant the rotor reaches 1500 rpm.
This is the difference between removing the induced EMF and removing an existing current.
Part (c): Long-term behaviour at 1500 rpm
After the initial transient has died away:
\[ n_r=n_s \]
Therefore:
\[ s=0 \]
and:
\[ f_r=0\text{ Hz} \]
The rotor current eventually falls to zero.
The electromagnetic torque produced by the fundamental induction mechanism also becomes zero.
The dynamometer must now provide the mechanical torque required to overcome the motor’s losses.
The motor cannot sustain a mechanical load using induction torque at exactly synchronous speed.
Part (d): Slip and rotor current frequency at 1512 rpm
The synchronous speed remains unchanged because the supply frequency and number of poles have not changed.
\[ n_s=1500\text{ rpm} \]
The rotor now turns at:
\[ n_r=1512\text{ rpm} \]
Calculate signed slip:
\[ s=\frac{1500-1512}{1500} \]
\[ s=\frac{-12}{1500} \]
\[ s=-0.008 \]
Therefore:
\[ s=-0.8\% \]
Calculate rotor current frequency:
\[ f_r=|s|f \]
\[ f_r=0.008\times50 \]
\[ f_r=0.4\text{ Hz} \]
The negative slip indicates that the rotor is now overtaking the stator’s rotating magnetic field.
Part (e): Torque direction and energy conversion
The electromagnetic torque now acts against the rotor’s clockwise rotation.
This follows from Lenz’s law: the induced effect opposes the relative motion responsible for producing it.
Because the rotor is being driven above synchronous speed, the external dynamometer must supply mechanical energy to maintain its rotation.
The machine operates as an induction generator, converting mechanical energy into electrical energy.
The tempting prediction is that reaching synchronous speed permanently switches off the motor’s electromagnetic behaviour.
The more accurate explanation is that synchronous speed is the point where steady-state induction torque becomes zero. Moving below or above that speed restores relative motion, allowing induction to occur again.
09Where this leads next
Synchronous speed is more than a reference value used in slip calculations. It determines whether an induction machine transfers energy from the electrical supply to a mechanical load or from a mechanical drive back into an electrical circuit.
The next useful step is to understand the induction motor’s torque-speed characteristic. It connects slip to electromagnetic torque, explains why increasing mechanical load causes the rotor to slow slightly, and shows how a motor can transition between motoring and generating operation.