How to Distinguish Eddy-Current Loss from Copper Loss

Learn how to separate copper loss from core loss in transformers using open-circuit tests, I²R calculations, and controlled comparisons. Includes worked examples and challenging HSC Physics questions with detailed solutions.

A transformer is connected to an AC supply, but its secondary circuit is disconnected. A wattmeter still shows that electrical power is being consumed. Is that power being lost in the copper windings or through eddy currents in the iron core?

The distinction is about where the current flows and what causes it. Copper loss, also called winding loss, is resistive heating caused by current flowing through the transformer’s windings. Eddy-current loss is resistive heating caused by circulating currents induced inside the conducting core.

To distinguish them, calculate winding losses using \(I^2R\), investigate how losses change with load, and compare core behaviour under controlled conditions. An open-circuit test helps estimate total core loss, while a comparison between solid and laminated cores can reveal the contribution from eddy currents.

There is one complication: core loss also includes hysteresis loss. You cannot automatically label every watt that isn’t copper loss as eddy-current loss.

01Why two different losses can produce the same heating

Imagine following electrical energy through a transformer.

Alternating current flows through the primary winding. This produces a changing magnetic flux in the core, which induces an emf in the secondary winding.

If the secondary is connected to a load, current flows through its copper wire. Both windings have resistance, so some electrical energy becomes thermal energy.

The power dissipated in a winding is

\[ P_{\mathrm{Cu}}=I^2R \]

where:

  • \(P_{\mathrm{Cu}}\) is copper loss in watts (W),
  • \(I\) is the RMS current in amperes (A), and
  • \(R\) is the winding resistance in ohms (\(\Omega\)).

RMS, or root mean square, is the AC current value that produces the same resistive heating as an equivalent DC current.

Now consider the steel core.

The changing magnetic flux also induces electric fields inside the conducting steel. These drive circulating eddy currents through the metal. Because steel has electrical resistance, those currents produce heat.

Here is the subtle part: eddy currents also cause resistive heating, so \(I^2R\) can describe a simplified eddy-current path too.

The equation alone cannot classify the loss. You must identify the conducting path.

FeatureCopper lossEddy-current loss
Where it occursPrimary and secondary windingsConducting transformer core
What drives the currentApplied voltage and electromagnetic induction associated with transformer operationChanging magnetic flux through conducting paths in the core
Main dependenceWinding current and resistanceChanging flux, core conductivity, and available current paths
Effect of increasing loadUsually increases substantially as winding currents riseApproximately unchanged if the core’s flux waveform remains unchanged
Common method of reductionLower-resistance windingsThin, electrically insulated core laminations

A third mechanism operates in the core. Hysteresis loss occurs as the magnetic material repeatedly changes its magnetisation under the alternating magnetic field.

Therefore,

\[ P_{\mathrm{core}} \approx P_{\mathrm{eddy}}+P_{\mathrm{hyst}} \]

Here \(P_{\mathrm{core}}\) is total core loss, \(P_{\mathrm{eddy}}\) is eddy-current loss, and \(P_{\mathrm{hyst}}\) is hysteresis loss. The approximation assumes other core-related losses are negligible.

This distinction is what makes experimental diagnosis interesting.

02The first experiment: disconnect the secondary

Suppose you want to determine whether a transformer consumes power even when it supplies no useful output.

Start with a low-voltage, isolated AC supply.

Connect the supply through an ammeter and the current-sensing part of a wattmeter to the primary winding. The wattmeter also measures the voltage across the primary.

The primary winding surrounds one limb of a closed steel core. The secondary winding surrounds another limb, but its two terminals are connected to an open switch.

For a second test, the switch can connect the secondary to a variable resistive load. A secondary ammeter measures load current, while a voltmeter measures the voltage across the load.

The winding resistances must also be known at their operating temperatures.

What should happen with the switch open?

Predict which copper losses disappear.

The secondary current becomes zero because its circuit is incomplete. Consequently, secondary winding copper loss is zero.

But primary current does not become zero.

The primary still draws a small no-load current to establish the alternating magnetic flux and supply the energy lost in the transformer.

That current heats the primary winding. Meanwhile, changing magnetic flux continues to produce eddy-current and hysteresis losses in the core.

In a real open-circuit test, the wattmeter therefore registers nonzero real power.

For this article, take electrical input power as positive into the transformer, useful output power as positive towards the load, and all losses as positive quantities.

With the secondary open,

\[ P_0\approx I_0^2R_p+P_{\mathrm{core}} \]

where:

  • \(P_0\) is measured no-load input power in watts,
  • \(I_0\) is measured no-load primary RMS current in amperes, and
  • \(R_p\) is primary winding resistance in ohms.

The secondary copper loss is zero in this arrangement.

Rearranging gives

\[ P_{\mathrm{core}} \approx P_0-I_0^2R_p \]

This is the first useful diagnostic calculation.

Worked example: What is the no-load power actually heating?

A transformer is connected to an isolated 24.0 V AC supply. Its secondary is disconnected.

The following illustrative readings are obtained:

  • True input power: \(2.80\ \mathrm{W}\)
  • Primary RMS current: \(0.25\ \mathrm{A}\)
  • Primary winding resistance: \(1.6\ \Omega\)

Calculate the primary copper loss and estimate the total core loss. Assume other losses are negligible.

Step 1

\[ \begin{aligned} P_{\mathrm{Cu},0}&=I_0^2R_p\\ &=(0.25)^2(1.6)\\ &=0.10\ \mathrm{W} \end{aligned} \]

Only 0.10 W is being dissipated in the primary winding.

Step 2

\[ \begin{aligned} P_{\mathrm{core}}&\approx P_0-P_{\mathrm{Cu},0}\\ &=2.80-0.10\\ &=2.70\ \mathrm{W} \end{aligned} \]

Step 3

The estimated total core loss is 2.70 W.

However, we cannot say that eddy currents account for all 2.70 W. Some may be hysteresis loss.

The first experiment has identified where most energy is being dissipated, but not which physical mechanism inside the core accounts for it.

Why not simply multiply voltage by current?

The primary voltage is 24.0 V and its current is 0.25 A.

Their product is

\[ VI=(24.0)(0.25)=6.0\ \mathrm{VA} \]

That is 6.0 volt-amperes of apparent power, not necessarily 6.0 watts of real power.

AC transformer current includes a magnetising component, which need not be in phase with the supply voltage.

For sinusoidal voltage and current,

\[ P=VI\cos\phi \]

where \(\phi\) is the phase angle between voltage and current, and \(\cos\phi\) is the power factor.

The wattmeter measures real input power. Multiplying RMS voltage by RMS current without considering power factor can substantially overestimate it.

That is why the 2.80 W wattmeter reading, not the 6.0 VA product, belongs in the energy-loss calculation.

03The second experiment: connect a load

The next question is whether the power loss changes when current begins flowing through the secondary.

Keep the primary supply voltage and frequency approximately constant, then connect a resistive load.

The secondary now delivers useful power. Both primary and secondary winding currents generally increase.

The core’s magnetic flux waveform remains approximately similar under ordinary operating conditions because the induced primary emf stays close to the applied AC voltage. Consequently, core loss is often treated as approximately constant as load changes.

Copper loss behaves differently.

For both windings,

\[ P_{\mathrm{Cu}} =I_p^2R_p+I_s^2R_s \]

Here:

  • \(I_p\) and \(I_s\) are the measured primary and secondary RMS currents,
  • \(R_p\) and \(R_s\) are their respective winding resistances, and
  • \(P_{\mathrm{Cu}}\) is their combined heating power in watts.

Notice the square on current. If current doubles while resistance stays constant, resistive heating becomes four times as large.

Separate ideal transformation from real losses

Before calculating heating, you may need the transformer’s turns ratio.

For an ideal transformer,

\[ \frac{V_s}{V_p}=\frac{N_s}{N_p} \]

where \(N_p\) and \(N_s\) are the primary and secondary numbers of turns, while \(V_p\) and \(V_s\) are their RMS voltages.

Conservation of energy for that ideal transformer also gives

\[ \frac{I_s}{I_p}=\frac{N_p}{N_s} \]

The ideal model assumes no winding resistance, no core losses, and no magnetising current.

That is useful for understanding how voltage and load-related current are transformed. But a real transformer’s measured primary current includes its excitation current and the effects of losses.

Use ideal ratios to establish the expected transformation. Use actual winding currents and resistances to calculate copper loss.

For a purely resistive secondary load, the useful output power is

\[ P_{\mathrm{out}}=V_sI_s \]

The total difference between real input and useful output is

\[ P_{\mathrm{loss}} =P_{\mathrm{in}}-P_{\mathrm{out}} \]

This total includes copper loss, eddy-current loss, hysteresis loss, and any other losses that have not been neglected.

Worked example: Is the missing power copper loss or core loss?

A transformer has 120 primary turns and 60 secondary turns. It is supplied with 24.0 V RMS at 50 Hz.

With a resistive load connected, the illustrative measurements are:

QuantityMeasured value
Primary input power27.0 W
Primary RMS current1.20 A
Secondary RMS voltage11.6 V
Secondary RMS current2.00 A
Primary resistance0.80 \(\Omega\)
Secondary resistance0.20 \(\Omega\)

An earlier open-circuit test at the same supply voltage and frequency gave a primary current of 0.20 A and an input power of 1.83 W.

Estimate the winding copper losses and remaining core loss during loaded operation. Assume the load is resistive and other losses are negligible.

Step 1

\[ \begin{aligned} V_{s,\mathrm{ideal}} &=\frac{N_s}{N_p}V_p\\ &=\frac{60}{120}(24.0)\\ &=12.0\ \mathrm{V} \end{aligned} \]

An ideal transformer would provide 12.0 V.

The measured 11.6 V is slightly lower because the real transformer has internal impedance and losses.

Step 2

Because the load is resistive,

\[ \begin{aligned} P_{\mathrm{out}}&=V_sI_s\\ &=(11.6)(2.00)\\ &=23.2\ \mathrm{W} \end{aligned} \]

Step 3

For the primary,

\[ \begin{aligned} P_{\mathrm{Cu},p} &=I_p^2R_p\\ &=(1.20)^2(0.80)\\ &=1.152\ \mathrm{W} \end{aligned} \]

For the secondary,

\[ \begin{aligned} P_{\mathrm{Cu},s} &=I_s^2R_s\\ &=(2.00)^2(0.20)\\ &=0.800\ \mathrm{W} \end{aligned} \]

The combined copper loss is

\[ \begin{aligned} P_{\mathrm{Cu}} &=1.152+0.800\\ &=1.952\ \mathrm{W} \end{aligned} \]

Step 4

The total loss is

\[ \begin{aligned} P_{\mathrm{loss}} &=27.0-23.2\\ &=3.80\ \mathrm{W} \end{aligned} \]

Subtracting copper loss,

\[ \begin{aligned} P_{\mathrm{core}} &\approx3.80-1.952\\ &=1.848\ \mathrm{W} \end{aligned} \]

So the loaded core-loss estimate is approximately 1.85 W.

Step 5

The earlier open-circuit test gave

\[ \begin{aligned} P_{\mathrm{core},0} &\approx1.83-(0.20)^2(0.80)\\ &=1.798\ \mathrm{W} \end{aligned} \]

The two estimates are close: approximately 1.80 W without load and 1.85 W under load.

That is consistent with core loss remaining approximately constant while the primary and secondary winding currents change.

The small difference could reflect rounding, measurement uncertainty, changes in core flux, or losses excluded from the simplified model.

Most importantly, the loaded transformer’s 3.80 W total loss is not entirely copper loss or entirely eddy-current loss.

04What the first experiment cannot prove

The open-circuit test gives us a method for estimating total core loss.

But suppose we want to identify the eddy-current part specifically.

The problem is that eddy-current and hysteresis losses occur together whenever the conducting magnetic core experiences alternating flux.

An open-circuit wattmeter cannot directly distinguish them.

We need a revised experiment that changes the opportunities for eddy currents to circulate without substantially changing the conditions responsible for hysteresis.

The revised test: solid core versus laminated core

Consider two transformers using equivalent windings and cores of the same steel grade, approximately the same magnetic material volume, and comparable geometry.

One uses a solid steel core. The other uses many thin steel laminations separated by electrical insulation.

The insulation interrupts large conducting paths through the core. Smaller circulating paths are still possible within individual sheets, so lamination reduces eddy-current loss rather than eliminating it entirely.

Would a laminated core necessarily produce a lower wattmeter reading?

You might predict yes, because lamination reduces eddy currents.

That prediction is reasonable, but it needs a qualification: the no-load primary current may also change when the core is replaced, and therefore primary copper heating can change.

We must correct both readings for their winding losses.

Illustrative comparison

Suppose both versions are tested at 24.0 V RMS and 50 Hz, with the same primary resistance of \(0.80\ \Omega\).

Assume the magnetic flux waveforms are matched, hysteresis losses are approximately equal, and other losses are negligible.

These are invented readings to illustrate the diagnostic method, not results from a reported experiment.

MeasurementSolid coreLaminated core
No-load primary current0.30 A0.20 A
No-load input power4.52 W1.83 W
Primary copper loss0.072 W0.032 W
Corrected total core loss4.448 W1.798 W

Subtracting the corrected core losses gives

\[ \begin{aligned} \Delta P_{\mathrm{core}} &=4.448-1.798\\ &=2.650\ \mathrm{W} \end{aligned} \]

Under the stated assumptions, the solid core dissipates approximately 2.65 W more through eddy currents than the laminated core.

Why can we make that inference?

The two cores have approximately the same hysteresis loss because their magnetic material and flux conditions have been held constant. The important change is the ability of electrical currents to circulate through the core.

Lamination disrupts those paths.

The reduction in corrected core loss can therefore be attributed primarily to reduced eddy-current heating.

But the result does not mean that the solid core’s entire 4.448 W was eddy-current loss, or that the laminated core has zero eddy-current loss.

Those would require additional information about hysteresis.

For the detailed physics of how insulation between steel sheets interrupts current paths, see Eddy-Current Losses in Transformers: HSC Physics Guide.

Why controlling the experiment matters

Suppose the laminated core had been made from a completely different magnetic material.

Its hysteresis loss could also change. A lower wattmeter reading would then be caused by some unknown combination of reduced eddy currents and changed hysteresis behaviour.

Likewise, comparing cores at different supply voltages or frequencies could change the magnetic flux, making the loss measurements difficult to interpret.

A sound investigation must therefore control or measure:

  • the magnetic material and approximate material volume,
  • the magnetic flux waveform,
  • supply frequency,
  • winding resistance and temperature, and
  • other significant sources of electrical loss.

Fixed primary voltage and frequency often give approximately similar flux conditions for otherwise identical transformers, but they do not guarantee identical core flux if the winding voltage drops or magnetic behaviour differ.

This is the limitation of the original no-load test and the reason for the controlled core comparison.

05A practical decision rule for HSC questions

When a transformer problem asks you to identify or calculate a loss, first establish what is being measured.

Given informationUseful methodWhat you can conclude
Primary and secondary RMS currents and winding resistances\(I_p^2R_p+I_s^2R_s\)Copper loss in both windings
No-load wattmeter power and primary winding resistance\(P_0-I_0^2R_p\)Approximate total core loss
Input power and useful output power\(P_{\mathrm{in}}-P_{\mathrm{out}}\)Total power loss
Corrected core losses for solid and laminated cores under matched magnetic conditionsCompare the two core-loss estimatesApproximate eddy-current reduction if hysteresis is unchanged
Only input power, output power, and turns ratioEnergy conservation and ideal transformation relationshipsNot enough to uniquely identify copper and eddy-current losses

There are three common mistakes worth avoiding.

First, do not assume that zero secondary load means zero copper loss. The primary still carries current.

Second, do not assume that a reduction in total transformer loss proves eddy-current loss has fallen. Winding currents and resistances may have changed.

Third, do not use the ideal transformer current ratio as though it automatically gives the measured primary current in a lossy transformer. The ideal ratio describes the underlying transformation, while \(I^2R\) heating must use appropriate real currents.

06Questions and solutions

The following questions use original, illustrative data. They progress from a typical HSC calculation to experimental comparisons that require more careful reasoning.

Question 1

A transformer is connected to an 18.0 V AC supply with its secondary circuit open.

A wattmeter measures 1.70 W of real input power. The primary RMS current is 0.25 A, and its winding resistance is \(1.6\ \Omega\).

Assuming other losses are negligible:

(a) Calculate the primary copper loss.

(b) Calculate the total core loss.

(c) Explain whether the result from part (b) is necessarily the eddy-current loss.

Solution 1

The primary copper loss is 0.10 W, and the estimated core loss is 1.60 W. The core-loss value includes both eddy-current and hysteresis losses, so it cannot be identified as eddy-current loss alone.

For the primary winding,

\[ \begin{aligned} P_{\mathrm{Cu}} &=I_0^2R_p\\ &=(0.25)^2(1.6)\\ &=0.10\ \mathrm{W} \end{aligned} \]

Because the secondary is open, its current and copper loss are zero.

The remaining power is

\[ \begin{aligned} P_{\mathrm{core}} &\approx P_0-P_{\mathrm{Cu}}\\ &=1.70-0.10\\ &=1.60\ \mathrm{W} \end{aligned} \]

The tempting mistake is to call the full 1.70 W eddy-current loss simply because the secondary is disconnected.

But the primary still heats, and the magnetic core experiences both eddy-current and hysteresis loss.

Question 2

A transformer has 120 primary turns and 60 secondary turns. Its primary supply is 30.0 V RMS at a constant frequency.

The winding resistances are:

  • Primary: \(0.80\ \Omega\)
  • Secondary: \(0.30\ \Omega\)

An open-circuit test gives:

  • Primary current: 0.15 A
  • Input power: 1.85 W

A resistor is then connected across the secondary.

The loaded measurements are:

  • Primary current: 1.10 A
  • Real input power: 32.0 W
  • Secondary terminal voltage: 14.0 V
  • Secondary current: 2.00 A

(a) Calculate the ideal secondary voltage and ideal load-related primary current for a 2.00 A secondary current.

(b) Calculate the actual combined copper loss under load.

(c) Use conservation of energy to estimate the core loss under load and compare it with the corrected open-circuit estimate.

(d) Explain why the ideal primary current must not replace the measured current in part (b).

Assume the external load is resistive and other losses are negligible.

Solution 2

The ideal transformation predicts 15.0 V and a load-related primary current of 1.00 A. However, the measured currents give a combined winding copper loss of 2.168 W. The core-loss estimate is 1.832 W in both the open-circuit and loaded tests.

Part (a): Ideal transformation

Using the turns ratio,

\[ \begin{aligned} V_{s,\mathrm{ideal}} &=\frac{60}{120}(30.0)\\ &=15.0\ \mathrm{V} \end{aligned} \]

The ideal primary current corresponding to the secondary load is

\[ \begin{aligned} I_{p,\mathrm{ideal}} &=\frac{60}{120}(2.00)\\ &=1.00\ \mathrm{A} \end{aligned} \]

The real secondary voltage is 14.0 V, not 15.0 V, because of the transformer’s non-ideal behaviour.

Part (b): Actual copper loss

Calculate heating using the measured primary and secondary currents.

\[ \begin{aligned} P_{\mathrm{Cu},p} &=(1.10)^2(0.80)\\ &=0.968\ \mathrm{W} \end{aligned} \]

\[ \begin{aligned} P_{\mathrm{Cu},s} &=(2.00)^2(0.30)\\ &=1.200\ \mathrm{W} \end{aligned} \]

Therefore,

\[ \begin{aligned} P_{\mathrm{Cu}} &=0.968+1.200\\ &=2.168\ \mathrm{W} \end{aligned} \]

Part (c): Energy balance

The resistor receives

\[ \begin{aligned} P_{\mathrm{out}} &=V_sI_s\\ &=(14.0)(2.00)\\ &=28.0\ \mathrm{W} \end{aligned} \]

The total transformer loss is

\[ P_{\mathrm{loss}}=32.0-28.0 =4.00\ \mathrm{W} \]

After subtracting copper loss,

\[ \begin{aligned} P_{\mathrm{core}} &\approx4.00-2.168\\ &=1.832\ \mathrm{W} \end{aligned} \]

Now use the open-circuit measurements:

\[ \begin{aligned} P_{\mathrm{core},0} &\approx1.85-(0.15)^2(0.80)\\ &=1.832\ \mathrm{W} \end{aligned} \]

Both estimates agree in this illustrative dataset.

That supports the approximation that core loss stays nearly constant when supply voltage, frequency, and core flux conditions remain similar.

Part (d): Why the ideal current is misleading

The ideal 1.00 A result describes current transformation in a lossless model without excitation current.

The real primary current is 1.10 A. Its magnetising and loss-related components mean that it cannot simply be replaced by the ideal current when calculating winding heating.

Using 1.00 A would underestimate primary copper loss because the heating depends on the square of the actual RMS current.

Question 3

Two transformers have interchangeable cores made from the same steel grade and approximately the same mass of magnetic material.

The primary winding resistance is \(2.0\ \Omega\) in both versions.

Both are tested at 30.0 V RMS and the same frequency. Independent magnetic measurements confirm that the core flux waveforms are matched.

The following no-load measurements are obtained:

MeasurementCore S: solidCore L: laminated
Primary current0.20 A0.70 A
Real input power3.20 W3.65 W

A student argues:

“The laminated transformer consumes more power with no load, so lamination must have increased eddy-current loss.”

(a) Calculate the corrected core loss for each transformer.

(b) Determine whether the student’s conclusion follows, assuming hysteresis loss is identical in both cores and other losses are negligible.

(c) Explain whether these measurements are sufficient to calculate the absolute eddy-current loss in either core.

Solution 3

The student is incorrect. Despite the laminated transformer drawing more total input power, its corrected core loss is 0.45 W lower. Under the given controls, this indicates a 0.45 W reduction in eddy-current loss.

Part (a): Correct each reading for primary copper loss

For the solid core,

\[ \begin{aligned} P_{\mathrm{Cu},S} &=(0.20)^2(2.0)\\ &=0.08\ \mathrm{W} \end{aligned} \]

Therefore,

\[ \begin{aligned} P_{\mathrm{core},S} &=3.20-0.08\\ &=3.12\ \mathrm{W} \end{aligned} \]

For the laminated core,

\[ \begin{aligned} P_{\mathrm{Cu},L} &=(0.70)^2(2.0)\\ &=0.98\ \mathrm{W} \end{aligned} \]

So,

\[ \begin{aligned} P_{\mathrm{core},L} &=3.65-0.98\\ &=2.67\ \mathrm{W} \end{aligned} \]

Part (b): Identify what changed

The solid core dissipates 3.12 W, while the laminated core dissipates 2.67 W.

The difference is

\[ \begin{aligned} \Delta P_{\mathrm{core}} &=3.12-2.67\\ &=0.45\ \mathrm{W} \end{aligned} \]

The laminated version has the lower core loss.

The apparently contradictory wattmeter reading comes from its much higher no-load primary current, which produces additional copper heating.

Its primary copper loss rises from 0.08 W to 0.98 W, an increase of 0.90 W.

The decrease in core loss of 0.45 W and increase in copper loss of 0.90 W produce a net input-power increase of 0.45 W.

Assuming the same hysteresis loss, the corrected core-loss decrease is attributable to reduced eddy-current heating.

Part (c): Can we identify absolute eddy-current loss?

No. We know the difference, but not the individual amounts.

Let \(H\) be the common hysteresis loss in watts. Then

\[ P_{\mathrm{eddy},S}=3.12-H \]

and

\[ P_{\mathrm{eddy},L}=2.67-H \]

Many nonnegative values of \(H\) could satisfy both measurements.

The eddy-current difference remains 0.45 W, but the absolute eddy-current loss depends on the unknown hysteresis contribution.

This is why even a carefully controlled lamination comparison normally gives stronger evidence about the reduction in eddy-current loss than about its absolute value.

Question 4

A transformer is tested with its secondary open at two different frequencies.

The primary RMS voltage remains fixed at 24.0 V. Its winding resistance is \(1.0\ \Omega\).

The readings are:

QuantityTest ATest B
Frequency50 Hz100 Hz
Primary current0.30 A0.20 A
Real input power6.09 W4.04 W

For this question, use the following simplified magnetic-loss model:

  1. The flux waveform is sinusoidal, and winding voltage drop is small enough that peak core flux density \(B_{\max}\) is inversely proportional to frequency \(f\) at fixed primary voltage.
  2. Eddy-current loss is proportional to \((fB_{\max})^2\).
  3. Hysteresis loss is proportional to \(fB_{\max}^2\).
  4. Other losses are negligible.

These scaling relationships are supplied as an extension model for this problem, not exact universal laws for magnetic materials or formulas you need to memorise for the HSC.

(a) Find the corrected core loss at each frequency.

(b) Determine the eddy-current and hysteresis losses at 50 Hz and 100 Hz under the supplied model.

(c) Explain why the higher frequency did not necessarily increase eddy-current loss.

Solution 4

The corrected core loss falls from 6.00 W at 50 Hz to 4.00 W at 100 Hz. Under the supplied model, eddy-current loss stays at 2.00 W, while hysteresis loss decreases from 4.00 W to 2.00 W.

Part (a): Remove primary copper loss

At 50 Hz,

\[ \begin{aligned} P_{\mathrm{core},50} &=6.09-(0.30)^2(1.0)\\ &=6.00\ \mathrm{W} \end{aligned} \]

At 100 Hz,

\[ \begin{aligned} P_{\mathrm{core},100} &=4.04-(0.20)^2(1.0)\\ &=4.00\ \mathrm{W} \end{aligned} \]

Part (b): Apply the supplied scaling relationships

The primary voltage remains fixed while frequency doubles.

Since \(B_{\max}\) is inversely proportional to frequency, the peak magnetic flux density halves.

Writing \(B_{50}\) and \(B_{100}\) for the peak flux densities,

\[ B_{100}=\frac{B_{50}}{2} \]

Eddy-current loss is proportional to the square of \(fB_{\max}\).

But

\[ \begin{aligned} f_{100}B_{100} &=(2f_{50})\frac{B_{50}}{2}\\ &=f_{50}B_{50} \end{aligned} \]

Therefore, the eddy-current loss is unchanged.

The hysteresis model contains one factor of frequency and two factors of magnetic flux density.

Doubling frequency while halving flux density reduces hysteresis loss to half its original value.

Let \(E\) be eddy-current loss and \(H\) be hysteresis loss at 50 Hz, both in watts.

The corrected measurements give

\[ \begin{aligned} E+H&=6.00\\ E+\frac{H}{2}&=4.00 \end{aligned} \]

Subtracting the equations,

\[ \frac{H}{2}=2.00 \]

Therefore,

\[ H=4.00\ \mathrm{W} \]

and

\[ E=6.00-4.00=2.00\ \mathrm{W} \]

At 100 Hz, eddy-current loss remains 2.00 W and hysteresis loss becomes 2.00 W.

Part (c): Explain the apparent paradox

A student might remember that faster-changing magnetic fields produce larger induced emfs and conclude that doubling frequency must increase eddy-current heating.

That would be reasonable if the magnetic flux amplitude stayed fixed.

Here it does not.

The supply voltage stays fixed, so the assumed peak magnetic flux density halves when frequency doubles.

The effects compensate: frequency doubles, flux amplitude halves, and the rate of flux change has the same peak magnitude.

Under the supplied model, the induced-current heating therefore remains unchanged.

The important lesson is to check which quantity is actually held constant. Fixed voltage is not the same condition as fixed magnetic flux density.

Question 5

A transformer with a 2:1 primary-to-secondary turns ratio is examined in two different low-voltage tests at 50 Hz.

Its winding resistances, measured at the relevant operating temperatures, are

\[ R_p=0.20\ \Omega \]

and

\[ R_s=0.050\ \Omega \]

The results are:

MeasurementTest OTest S
Secondary connectionOpen circuitShort circuit
Applied primary RMS voltage24.0 V2.4 V
Primary RMS current0.25 A3.0 A
Secondary RMS current0 A6.0 A
Real input power3.10 W3.65 W
Useful output power0 W0 W

The short-circuit test is performed with a controlled, isolated, reduced-voltage source. The shorting connection has negligible resistance. It is not a test to attempt on an ordinary mains-connected transformer.

An independent magnetic measurement finds that the peak core flux density in Test S is exactly one-tenth that in Test O.

For this idealised model, assume:

  • the core is unchanged between tests,
  • the only losses are winding copper loss, eddy-current loss, and hysteresis loss,
  • hysteresis loss is nonnegative, and
  • at fixed frequency, eddy-current loss is proportional to the square of peak magnetic flux density.

A student observes that Test S consumes more input power than Test O, despite both delivering zero useful power.

The student concludes:

“Test S must have greater eddy-current loss. There is more electrical power being wasted, and neither transformer is supplying a load.”

(a) Calculate copper loss and combined core loss in both tests.

(b) Explain which test has greater winding copper loss and which has greater eddy-current loss under the supplied model.

(c) Use the experimental results to prove that at least some of the 0.050 W core loss in Test S must be hysteresis loss. Calculate the minimum amount.

(d) Explain whether the individual eddy-current losses can be determined exactly.

Solution 5

The student is incorrect. Test S has far greater copper loss, despite delivering no useful output power. Test O has greater eddy-current loss under the supplied model because its magnetic flux amplitude is ten times larger.

The strongest conclusion is that Test S must have at least 0.0191 W of hysteresis loss. The measurements do not uniquely determine the absolute eddy-current loss in either test.

Part (a): Calculate the two kinds of loss

Start with Test O.

The secondary is open, so its current is zero. Only the primary winding has copper loss.

\[ \begin{aligned} P_{\mathrm{Cu},O} &=(0.25)^2(0.20)\\ &=0.0125\ \mathrm{W} \end{aligned} \]

The remaining input power is dissipated in the core:

\[ \begin{aligned} P_{\mathrm{core},O} &=3.10-0.0125\\ &=3.0875\ \mathrm{W} \end{aligned} \]

Now consider Test S.

The secondary is shorted, but that does not make its current zero. In fact, its current is 6.0 A.

The primary winding dissipates

\[ \begin{aligned} P_{\mathrm{Cu},p,S} &=(3.0)^2(0.20)\\ &=1.80\ \mathrm{W} \end{aligned} \]

The secondary winding dissipates

\[ \begin{aligned} P_{\mathrm{Cu},s,S} &=(6.0)^2(0.050)\\ &=1.80\ \mathrm{W} \end{aligned} \]

Total copper loss is

\[ P_{\mathrm{Cu},S} =1.80+1.80 =3.60\ \mathrm{W} \]

The remaining core loss is

\[ \begin{aligned} P_{\mathrm{core},S} &=3.65-3.60\\ &=0.050\ \mathrm{W} \end{aligned} \]

These results reveal two very different energy distributions.

Calculated lossTest OTest S
Total copper loss0.0125 W3.60 W
Combined core loss3.0875 W0.050 W

The short-circuit test has a larger input-power reading, but nearly all of it is being dissipated in the windings.

Part (b): Why zero useful output does not imply the same loss

Both tests deliver zero useful power, but for completely different reasons.

In Test O, the secondary is open. Current cannot flow through the secondary winding. The primary still establishes a substantial alternating magnetic flux in the core.

That produces eddy-current and hysteresis losses.

In Test S, the secondary has a closed path of very low external resistance. Large currents can flow in both windings even though the voltage across the ideal shorting connection is zero.

The experiment uses a much lower primary voltage to limit those currents.

The independent magnetic measurement confirms that the core flux amplitude is only one-tenth of its value in Test O.

Under the supplied eddy-current model,

\[ P_{\mathrm{eddy}}\propto B_{\max}^2 \]

Therefore,

\[ \begin{aligned} \frac{P_{\mathrm{eddy},S}} {P_{\mathrm{eddy},O}} &=(0.10)^2\\ &=0.010 \end{aligned} \]

Test S has just one-hundredth of the eddy-current loss in Test O, provided the loss is nonzero.

This is the central surprise: zero useful output does not tell you whether power is primarily being lost in the windings or the core.

You must look at the current paths and the magnetic conditions.

Part (c): Establish a limit on eddy-current loss

The total core loss in Test O is 3.0875 W.

Because hysteresis loss cannot be negative, eddy-current loss cannot exceed the entire core loss.

Thus,

\[ P_{\mathrm{eddy},O} \leq3.0875\ \mathrm{W} \]

From the flux relationship,

\[ P_{\mathrm{eddy},S} =0.010P_{\mathrm{eddy},O} \]

Therefore,

\[ \begin{aligned} P_{\mathrm{eddy},S} &\leq0.010(3.0875)\\ &\leq0.030875\ \mathrm{W} \end{aligned} \]

But the measured combined core loss in Test S is 0.050 W.

So even if eddy-current loss were as large as the model permits, it could account for no more than 0.030875 W.

The rest must be hysteresis loss under the stated assumptions.

\[ \begin{aligned} P_{\mathrm{hyst},S} &\geq0.050-0.030875\\ &\geq0.019125\ \mathrm{W} \end{aligned} \]

Therefore, at least approximately 0.0191 W of Test S’s core loss must be hysteresis loss.

A tempting alternative would be to declare all 0.050 W in Test S to be eddy-current loss.

But then the assumed magnetic scaling would require Test O to have

\[ \frac{0.050}{0.010} =5.0\ \mathrm{W} \]

of eddy-current loss.

That is impossible because Test O’s entire corrected core loss is only 3.0875 W.

The contradiction proves that the 0.050 W cannot all be eddy-current loss under the supplied model.

Part (d): Can we determine exact eddy-current losses?

No.

We have established a relationship between the eddy-current losses in the two tests, but we have not measured the hysteresis contribution independently.

The loss equations are

\[ \begin{aligned} P_{\mathrm{eddy},O} +P_{\mathrm{hyst},O} &=3.0875\\ P_{\mathrm{eddy},S} +P_{\mathrm{hyst},S} &=0.050 \end{aligned} \]

with all powers in watts and

\[ P_{\mathrm{eddy},S} =0.010P_{\mathrm{eddy},O} \]

These constraints allow a range of possible eddy-current and hysteresis combinations.

An additional independent measurement or justified model of hysteresis would be needed to determine the individual values.

That is the difference between finding a loss, estimating a loss, and proving a bound on a loss.

When solving transformer questions, always ask what the measurements actually identify. An energy balance can tell you how much power is missing. A winding resistance calculation tells you how much becomes heat in copper. But identifying the eddy-current contribution requires information about what is happening inside the magnetic core.

The same reasoning becomes useful in magnetic braking. There, motion rather than a transformer’s electrical supply provides the energy driving induced currents. The energy source changes, but the diagnostic principle stays the same: identify the current path, establish what drives it, and account for where the energy is dissipated.