Graham’s Law of Effusion: Molar Mass and Gas Escape Rates

Learn why lighter gases effuse faster, how to calculate effusion rates using molar mass, and why effusion differs from diffusion and bulk flow. Includes worked examples, model limitations, and five practice questions with detailed solutions.

Two sealed containers hold different gases at exactly the same temperature and pressure. Each has an identical microscopic opening into a vacuum. One contains helium, and the other contains argon.

Which container loses gas particles faster?

You might predict that both lose particles at the same rate because their pressures are equal. But helium escapes about three times faster. The difference comes from how quickly individual particles move, not how hard the gas pushes overall.

Graham’s law of effusion lets us predict that difference using just the gases’ molar masses.

Syllabus note: Graham’s law of effusion is extension material beyond the required NSW Chemistry 11-12 Syllabus (2025). The Year 11 focus area Quantitative chemistry, together with particle theory, provides the foundation. The 2025 syllabus begins implementation for Year 11 in 2028. This article develops an additional idea, not a required assessment calculation.

01Why lighter gases escape faster

Start with something familiar from particle theory: gas particles move constantly and randomly.

They travel through their container, collide with other particles, strike the walls, and change direction. These collisions produce gas pressure.

Temperature tells us something different. For an ideal gas, the average translational kinetic energy of its particles depends only on absolute temperature, measured in kelvin.

That means helium and argon at the same temperature have the same average kinetic energy per particle.

But they don’t have the same average speed.

Think about two moving objects, such as a tennis ball and a bowling ball. A much lighter object needs a higher speed to have the same kinetic energy as a heavier one.

Gas particles follow the same mass-speed relationship.

The kinetic energy of a moving particle is:

\[ E_k=\frac12 mv^2 \]

Here:

  • \(E_k\) is the particle’s kinetic energy, in joules (J).
  • \(m\) is its mass, in kilograms (kg).
  • \(v\) is its speed, in metres per second (m/s).

If two particles have equal kinetic energy, the lighter particle must move faster.

In a gas, particles have a range of speeds rather than one identical speed. At the same temperature, however, the characteristic speeds of lighter particles are greater.

Now imagine a tiny opening in the wall.

Particles inside the container continually approach it from different directions. Some happen to reach the opening while travelling towards it and pass through.

At equal temperature and pressure, ideal gases have the same number of particles per unit volume. The faster helium particles reach the opening more frequently.

More helium atoms therefore escape per second.

Notice what isn’t happening: the opening isn’t selectively attracting helium. The particles move randomly, and the faster-moving gas produces more crossings.

02Effusion, diffusion, and bulk mixing are different processes

Graham’s law describes a particular way that gas particles pass through an opening.

Effusion: particles escaping through a tiny opening

Effusion is the passage of gas particles through an opening small enough that collisions between particles within the opening can be neglected.

Imagine a rigid vessel containing gas, separated from an evacuated chamber by a thin wall with a microscopic hole.

A particle travels towards the opening, passes through without colliding with another particle inside it, and enters the low-pressure region.

The important condition concerns the mean free path: the average distance a particle travels between collisions with other gas particles.

For the simplest molecular-effusion model, the opening must be much smaller than the mean free path. The wall should also be thin enough that the opening doesn’t behave like a long tube.

Diffusion: particles spreading and mixing

Suppose you open a bottle of perfume at one end of a room.

Its molecules don’t need to pass through a microscopic hole to reach the other end. They move randomly, collide with air molecules, and gradually spread.

This is diffusion: the net spreading of particles from a region of higher concentration to one of lower concentration because of random molecular motion.

Diffusion and effusion both involve moving particles, but they’re not interchangeable.

During diffusion through another gas, collisions, concentration differences, and molecular interactions influence the transport rate. You cannot generally predict the time taken for two gases to mix using Graham’s effusion equation alone.

Bulk flow: the gas moves as a whole

Now consider air flowing through a wide pipe because a fan creates a pressure difference.

The gas moves collectively, although its individual particles still move randomly.

This is bulk flow.

The flow rate depends on pressure differences, pipe geometry, and fluid behaviour. A simple inverse-square-root molar-mass relationship isn’t enough.

This distinction matters whenever you encounter a real gas leak.

A tiny hole in a thin wall under molecular-flow conditions can follow Graham’s law. A wide opening, a long capillary, or a polymer membrane may behave differently.

03Graham’s law: connecting effusion rate to molar mass

The model gives us a useful prediction.

At the same temperature and pressure, with identical openings operating under molecular-effusion conditions, the rate at which particles escape is inversely proportional to the square root of their molar mass.

In symbols:

\[ r\propto\frac{1}{\sqrt{M}} \]

Here:

  • \(r\) is the molar effusion rate, measured in moles per second (mol/s).
  • \(M\) is the molar mass of the gas, measured in grams per mole (g/mol).
  • \(\propto\) means “is proportional to”.

Molar mass is the mass of one mole of particles, a quantity you’ve already used in Year 11 chemistry.

For two gases, A and B, Graham’s law becomes:

\[ \frac{r_A}{r_B} =\sqrt{\frac{M_B}{M_A}} \]

The subscripts A and B identify the gases. The molar masses must be expressed in the same units.

Read the equation carefully. Gas A’s rate is on top, but gas B’s molar mass is on top inside the square root.

That’s the inverse relationship.

If gas A has one-quarter the molar mass of gas B, it effuses twice as fast under the stated conditions, not four times as fast.

Worked example: How quickly does helium effuse compared with neon?

Two identical vessels contain pure helium and neon at the same temperature and initial pressure. Each has an identical molecular-effusion opening into a maintained vacuum.

Neon initially escapes at \(0.0120\ \mathrm{mmol/s}\). Calculate the initial effusion rate of helium.

Use:

  • Helium molar mass: \(4.00\ \mathrm{g/mol}\)
  • Neon molar mass: \(20.0\ \mathrm{g/mol}\)

One millimole (mmol) is \(10^{-3}\) mol.

Step 1

Helium has a smaller molar mass, so its particles have a higher characteristic speed at the same temperature.

Its effusion rate should therefore be greater than neon’s.

Step 2

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{Ne}}} &=\sqrt{\frac{20.0}{4.00}}\\ &=\sqrt5\\ &=2.236 \end{aligned} \]

Step 3

\[ \begin{aligned} r_{\mathrm{He}} &=2.236\,r_{\mathrm{Ne}}\\ &=2.236(0.0120)\\ &=0.0268\ \mathrm{mmol/s} \end{aligned} \]

Helium initially escapes at approximately \(0.0268\ \mathrm{mmol/s}\), or 2.24 times neon’s rate.

The result makes physical sense: helium is lighter, so more particles reach the opening per second.

The word initially matters. As a sealed vessel loses gas, its pressure drops, and its effusion rate changes.

04What if the gas pressures aren’t equal?

Here’s a prediction worth testing.

Imagine two gases at the same temperature, but one has far fewer particles per unit volume.

Even if that gas’s particles move faster, fewer of them are available to reach the opening.

Could a heavier gas therefore effuse faster than a lighter one?

Yes.

We need to consider both particle speed and the number of particles near the opening.

For an ideal gas at a fixed temperature, the number of particles per unit volume is proportional to pressure.

For a gas mixture, we use the partial pressure of each gas.

Partial pressure means the pressure that one component would exert if it alone occupied the entire container at the same temperature and volume.

For ideal gases:

\[ p_i=x_iP \]

Here:

  • \(p_i\) is the partial pressure of gas \(i\), in kilopascals (kPa).
  • \(x_i\) is its mole fraction: its number of moles divided by the total number of moles.
  • \(P\) is the total gas pressure, in kPa.
  • \(i\) simply identifies the particular gas.

At equal temperatures and with the same molecular-effusion opening, the more general rate comparison is:

\[ \frac{r_A}{r_B} =\frac{p_A}{p_B} \sqrt{\frac{M_B}{M_A}} \]

This compares the molar rates of two gases using their source-side partial pressures.

For pure gases, partial pressure is just the gas pressure.

Worked example: Can oxygen escape faster than helium?

A rigid container holds an ideal mixture of helium and oxygen at constant temperature. A microscopic opening leads into a maintained vacuum.

The partial pressures are:

  • Helium: \(30\ \mathrm{kPa}\)
  • Oxygen: \(120\ \mathrm{kPa}\)

Their molar masses are \(4.00\ \mathrm{g/mol}\) and \(32.0\ \mathrm{g/mol}\), respectively.

Calculate which gas has the greater instantaneous molar effusion rate. Then determine the mole fraction of helium among particles escaping at that instant.

Step 1

Helium is lighter and moves faster on average.

But oxygen has four times the partial pressure, so there are four times as many oxygen molecules per unit volume as helium atoms.

We need both factors.

Step 2

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{O_2}}} &=\frac{30}{120} \sqrt{\frac{32.0}{4.00}}\\ &=0.25\sqrt8\\ &=0.707 \end{aligned} \]

So helium escapes at only 70.7% of oxygen’s molar rate.

Oxygen has the greater instantaneous molar effusion rate despite being heavier.

Step 3

We have an escaping rate ratio of \(0.707:1\).

The helium fraction is:

\[ \begin{aligned} x_{\mathrm{He,out}} &=\frac{0.707}{0.707+1}\\ &=0.414 \end{aligned} \]

Therefore, about 41.4% of the particles escaping at that instant are helium atoms.

Step 4

Inside the vessel, helium’s mole fraction is:

\[ x_{\mathrm{He}} =\frac{30}{30+120} =0.200 \]

Only 20.0% of the gas particles inside are helium, but 41.4% of those escaping at that instant are helium.

The escaping gas is enriched in helium relative to the original mixture, even though more oxygen molecules than helium atoms escape per second.

That’s an important distinction. Being preferentially represented in the escaping gas doesn’t necessarily mean having the larger total escaping rate.

05Three limits you shouldn’t ignore

Graham’s law is powerful because it isolates one variable: molar mass. That is also why you need to be careful about applying it.

1. It describes molecular effusion, not every leak

The simple model assumes that the opening is much smaller than the mean free path, so collisions within the opening are negligible.

A thin opening and a long, narrow tube are not necessarily equivalent. Gas can collide with tube walls or with other particles, changing the relationship between pressure, molar mass, and flow.

A gas travelling through an ordinary piece of tubing or a large opening cannot automatically be treated using Graham’s law.

2. It compares particle rates, not necessarily mass-loss rates

A mole of helium has much less mass than a mole of oxygen.

So a container losing helium particles more quickly may still lose less mass per second than another container losing heavier particles.

The mass-loss rate is:

\[ \dot m=Mr \]

Here \(\dot m\) is the mass lost per second, measured in grams per second (g/s), when \(M\) is in g/mol and \(r\) is in mol/s.

The dot over \(m\) indicates a rate of change, rather than the total mass.

A greater molar effusion rate does not automatically mean a greater mass-loss rate.

3. Conditions change as gas escapes

For a rigid ideal-gas container held at constant temperature, pressure decreases as the number of gas particles decreases.

The effusion rate therefore slows over time.

If two gases are mixed, their partial pressures can change at different rates. The composition of the escaping gas can change too.

And if a gas enters another region that already contains gas, particles may cross the opening in both directions.

To predict the net movement, you need to account for both directions rather than treating the receiving region as a vacuum.

These limits explain why Graham’s law is best understood as a model of molecular motion rather than a universal rule for how quickly a container empties.

The OpenStax treatment of diffusion and effusion explains the basic particle distinction, while the University of Texas molecular-effusion model describes the more precise small-opening condition and molecular crossings from both sides.

06Questions and solutions

The questions become progressively more demanding. All apparatus and measurements are hypothetical. Unless stated otherwise, assume ideal gases, constant temperature, identical thin molecular-effusion openings, negligible gas reactions, and sufficiently well-mixed containers.

Question 1

Two vessels contain helium and argon at the same temperature and pressure. They have identical microscopic openings into separate maintained vacuums.

The molar masses are:

  • Helium: \(4.00\ \mathrm{g/mol}\)
  • Argon: \(40.0\ \mathrm{g/mol}\)

If argon initially effuses at \(2.00\times10^{-4}\ \mathrm{mol/s}\), calculate the initial effusion rate of helium. Explain which gas is faster and why.

Solution 1

Helium effuses approximately 3.16 times as fast as argon, giving an initial rate of \(6.32\times10^{-4}\ \mathrm{mol/s}\).

Using Graham’s law:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{Ar}}} &=\sqrt{\frac{40.0}{4.00}}\\ &=\sqrt{10}\\ &=3.162 \end{aligned} \]

Therefore:

\[ \begin{aligned} r_{\mathrm{He}} &=3.162(2.00\times10^{-4})\\ &=6.32\times10^{-4}\ \mathrm{mol/s} \end{aligned} \]

Helium has a smaller molar mass. At equal temperature, its atoms move faster on average and reach the opening more frequently.

The tempting mistake is to divide the molar masses directly and predict a tenfold difference. Graham’s law uses the square root of the inverse molar-mass ratio, so the rate difference is only about 3.16.

Question 2

Two identical rigid vessels, each of volume \(2.00\ \mathrm{L}\), initially contain pure gases at the same temperature and pressure.

Vessel A contains helium, with molar mass \(4.00\ \mathrm{g/mol}\).

Vessel B contains oxygen, \(\ce{O2}\), with molar mass \(32.0\ \mathrm{g/mol}\).

Each vessel has an identical molecular-effusion opening into its own maintained vacuum.

During a very short interval, vessel A loses \(1.60\times10^{-3}\ \mathrm{mol}\) of helium. Assume both rates remain approximately constant during this interval.

A pressure sensor and a balance are used to monitor each vessel.

Determine:

a. The number of moles of oxygen lost during the same interval.

b. The mass lost from each vessel, in grams.

c. Which vessel experiences the larger pressure decrease, and by what factor.

d. Why the pressure and mass measurements appear to favour different gases.

Solution 2

The helium vessel loses more moles and experiences the larger pressure drop, but the oxygen vessel loses more mass. Both measurements are consistent with Graham’s law.

Part a: Oxygen moles lost

First calculate the molar rate ratio:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{O_2}}} &=\sqrt{\frac{32.0}{4.00}}\\ &=\sqrt8\\ &=2.828 \end{aligned} \]

Because the time interval is the same and both rates are approximately constant, the ratio of amounts lost is also 2.828.

\[ \begin{aligned} n_{\mathrm{O_2}} &=\frac{1.60\times10^{-3}}{2.828}\\ &=5.66\times10^{-4}\ \mathrm{mol} \end{aligned} \]

Here \(n_{\mathrm{O_2}}\) is the amount of oxygen lost, in moles.

Part b: Mass losses

Use \(m=nM\), where \(m\) is mass in grams, \(n\) is amount in moles, and \(M\) is molar mass in g/mol.

For helium:

\[ \begin{aligned} m_{\mathrm{He}} &=(1.60\times10^{-3})(4.00)\\ &=0.00640\ \mathrm{g} \end{aligned} \]

For oxygen:

\[ \begin{aligned} m_{\mathrm{O_2}} &=(5.66\times10^{-4})(32.0)\\ &=0.0181\ \mathrm{g} \end{aligned} \]

The oxygen vessel loses about 2.83 times as much mass as the helium vessel.

Part c: Pressure changes

For an ideal gas:

\[ PV=nRT \]

Here \(P\) is pressure, \(V\) is volume, \(n\) is the amount of gas, \(R\) is the ideal gas constant, and \(T\) is absolute temperature in kelvin.

Since both vessels have the same fixed volume and temperature, the pressure decrease is proportional to the number of moles lost.

Thus:

\[ \frac{\Delta P_{\mathrm{He}}} {\Delta P_{\mathrm{O_2}}} = \frac{1.60\times10^{-3}} {5.66\times10^{-4}} =2.83 \]

The symbol \(\Delta P\) represents the magnitude of the pressure decrease.

Vessel A experiences a pressure decrease about 2.83 times as large.

Part d: Resolving the apparent disagreement

The instruments measure different things.

The pressure sensor responds to changes in particle number per unit volume at fixed temperature, while the balance responds to mass.

Helium loses more particles but each helium atom has less mass. Oxygen loses fewer particles, yet each oxygen molecule is much heavier.

The trap is assuming that faster effusion must mean faster loss of mass. Graham’s law, as used here, compares molar rates.

Question 3

A researcher investigates the movement of helium and carbon dioxide through two different barriers.

Both gases are tested separately at the same temperature and source pressure, with a negligible receiving-side pressure.

The molar masses are:

  • Helium: \(4.00\ \mathrm{g/mol}\)
  • Carbon dioxide: \(44.0\ \mathrm{g/mol}\)

The hypothetical results are:

Barrier X: A thin, rigid wall with a single hole much smaller than the mean free path. Helium crosses approximately 3.3 times as fast as carbon dioxide, measured in moles per second.

Barrier Y: A continuous polymer film without holes. Carbon dioxide crosses faster than helium.

A student concludes:

“These experiments contradict each other. Graham’s law predicts helium is faster, so the second experiment must be wrong.”

Assess this conclusion.

Explain the main transport mechanism for each barrier, determine whether either result contradicts Graham’s law, and describe why replacing Barrier X with a wide open tube would change the analysis.

Solution 3

There is no contradiction. Barrier X is suitable for Graham’s molecular-effusion model, while Barrier Y involves transport through a solid material, which depends on more than molar mass.

Barrier X

The opening is much smaller than the mean free path, so particles can cross without significant collisions within the opening.

Graham’s law predicts:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{CO_2}}} &=\sqrt{\frac{44.0}{4.00}}\\ &=\sqrt{11}\\ &=3.32 \end{aligned} \]

The predicted helium-to-carbon-dioxide molar rate ratio is approximately \(3.32:1\).

This agrees with the stated result of about \(3.3:1\).

Barrier Y

A continuous polymer film has no open passage through which gas molecules simply travel freely.

Gas transport may involve molecules entering the polymer, moving through its structure, and leaving on the other side.

The rate depends on factors including how readily each gas enters the material and how easily it moves through it. These properties depend on the particular gas-polymer combination.

Consequently, it’s possible for carbon dioxide to cross a particular polymer faster than helium, even though helium particles have higher characteristic speeds.

That result doesn’t contradict Graham’s law because the required molecular-effusion mechanism isn’t present.

Replacing Barrier X with a wide tube

A wide opening can allow frequent collisions and bulk gas flow rather than collision-free molecular effusion.

Pressure-driven flow, gas viscosity, and tube geometry can then influence the observed rate.

The original square-root comparison is no longer sufficient.

The key is to identify the physical transport mechanism before choosing an equation. Selecting Graham’s law simply because two gases cross a barrier is the misconception.

Question 4

A rigid vessel initially contains a well-mixed gas mixture at constant temperature:

  • \(0.100\ \mathrm{mol}\) of helium
  • \(0.100\ \mathrm{mol}\) of methane, \(\ce{CH4}\)

Their molar masses are \(4.00\ \mathrm{g/mol}\) and \(16.0\ \mathrm{g/mol}\), respectively.

The gas escapes slowly through one molecular-effusion opening into a continuously evacuated outlet. Every escaping particle is counted, and no particles return.

After some time, the vessel contains:

  • \(0.0250\ \mathrm{mol}\) of helium
  • \(0.0500\ \mathrm{mol}\) of methane

Determine:

a. The instantaneous helium-to-methane molar effusion rate ratio at this later moment.

b. The mole fraction of helium among the particles escaping at that moment.

c. The mole fraction of helium in all the gas collected since effusion began.

d. The helium mole fraction in the gas escaping initially, and why it differs from the later and cumulative values.

Solution 4

At the later moment, the escaping gas is 50.0% helium, while all the gas collected so far is 60.0% helium. Initially, the escaping gas was 66.7% helium.

The three values differ because instantaneous composition is not the same as accumulated composition.

Part a: Instantaneous rate ratio

At constant temperature and volume, an ideal gas’s partial pressure is proportional to its number of moles.

Therefore:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{CH_4}}} &=\frac{0.0250}{0.0500} \sqrt{\frac{16.0}{4.00}}\\ &=0.500(2.00)\\ &=1.00 \end{aligned} \]

The instantaneous molar effusion rates are equal.

This doesn’t mean the particles have equal speeds. Helium atoms are still faster on average, but there are only half as many helium atoms as methane molecules inside the vessel.

The two effects balance.

Part b: Composition of the gas escaping now

Equal rates mean equal numbers of helium and methane particles escape per second.

So the instantaneous helium mole fraction is:

\[ x_{\mathrm{He,out}} =\frac{1}{1+1} =0.500 \]

The gas escaping now is 50.0% helium.

Part c: Composition of all collected gas

Use conservation of particles.

Helium collected:

\[ \begin{aligned} n_{\mathrm{He,col}} &=0.100-0.0250\\ &=0.0750\ \mathrm{mol} \end{aligned} \]

Methane collected:

\[ \begin{aligned} n_{\mathrm{CH_4,col}} &=0.100-0.0500\\ &=0.0500\ \mathrm{mol} \end{aligned} \]

The helium fraction among everything collected is:

\[ \begin{aligned} x_{\mathrm{He,col}} &=\frac{0.0750}{0.0750+0.0500}\\ &=0.600 \end{aligned} \]

So the cumulative collected gas is 60.0% helium.

Part d: Initial escaping composition

At the beginning, the two gases had equal amounts and therefore equal partial pressures.

Graham’s law gives:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{CH_4}}} &=\sqrt{\frac{16.0}{4.00}}\\ &=2.00 \end{aligned} \]

Initially, helium escaped twice as quickly in moles per second.

Its fraction of the initial escaping gas was:

\[ x_{\mathrm{He,initial}} =\frac{2}{2+1} =\frac23 \approx0.667 \]

So the initial escaping gas was 66.7% helium.

Helium is preferentially lost early, reducing its partial pressure more rapidly. The remaining vessel becomes relatively richer in methane.

The collected gas combines everything that escaped earlier, including the initially helium-rich gas. That’s why its cumulative composition differs from the composition escaping at one particular moment.

The tempting prediction is that helium must always make up two-thirds of the escaping gas because its molar mass never changes. The missing condition is the changing partial-pressure ratio.

Question 5

Two identical rigid chambers, L and R, are held at the same constant temperature and have equal volumes.

They are separated by a thin wall with one microscopic opening. The opening is much smaller than the mean free paths on both sides throughout the experiment, so the molecular-effusion model applies.

Initially:

  • Chamber L contains pure helium at \(100\ \mathrm{kPa}\).
  • Chamber R contains pure methane at \(100\ \mathrm{kPa}\).

The gases behave ideally, remain well mixed within each chamber, and cannot escape the combined two-chamber system.

Their molar masses are:

  • Helium: \(4.00\ \mathrm{g/mol}\)
  • Methane: \(16.0\ \mathrm{g/mol}\)

As particles cross the opening, measurements give the following partial pressures:

Gas partial pressureInstant A: LInstant A: RLater instant B: LLater instant B: R
Helium82 kPa18 kPa58 kPa42 kPa
Methane10 kPa90 kPa30 kPa70 kPa

Because the opening allows collision-free molecular crossings, each gas can cross in both directions. For each species, the net molar transfer rate is proportional to the difference in its partial pressures divided by the square root of its molar mass.

A student argues:

“Both chambers started at equal total pressure. Once chamber R has a higher total pressure, the net movement of particles must be from R to L until equilibrium.”

Determine:

a. The direction of net particle transfer at instant A.

b. The direction of net mass transfer at instant A.

c. The direction of net particle transfer at instant B.

d. Whether the student’s prediction is correct.

e. The final partial pressures and total pressure in both chambers at equilibrium.

Explain how the direction of net particle transfer can change even though helium continues to move net from L to R and methane continues to move net from R to L.

Solution 5

At instant A, net particle transfer is from L to R, even though L has the lower total pressure. However, net mass transfer is from R to L. At instant B, net particle transfer has reversed and is now from R to L.

Eventually, each chamber contains helium at \(50\ \mathrm{kPa}\) and methane at \(50\ \mathrm{kPa}\), giving a total pressure of \(100\ \mathrm{kPa}\).

The surprising result comes from treating particle movement, mass movement, and individual gas partial pressures as three different things.

Part a: Net particle transfer at instant A

First calculate the total pressures.

For chamber L:

\[ P_L=82+10=92\ \mathrm{kPa} \]

For chamber R:

\[ P_R=18+90=108\ \mathrm{kPa} \]

A prediction based only on total pressure would suggest that particles must move net from R to L.

But the opening operates under molecular-effusion conditions, and the two gases can move in opposite directions.

Helium has a higher partial pressure on the left, so its net movement is from L to R.

Methane has a higher partial pressure on the right, so its net movement is from R to L.

For each species, the net transfer rate is proportional to:

\[ \frac{\Delta p}{\sqrt{M}} \]

Here \(\Delta p\) is the positive magnitude of that species’ partial-pressure difference between chambers, in kPa, and \(M\) is its molar mass.

At instant A:

  • Helium’s pressure difference is \(82-18=64\ \mathrm{kPa}\).
  • Methane’s pressure difference is \(90-10=80\ \mathrm{kPa}\).

Compare the magnitudes of their net molar transfer rates:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{CH_4}}} &=\frac{64}{80} \sqrt{\frac{16.0}{4.00}}\\ &=0.800(2.00)\\ &=1.60 \end{aligned} \]

Here the rates are magnitudes in opposite directions.

For every 1.00 mole of methane transferred net from R to L, 1.60 moles of helium are transferred net from L to R.

Therefore, the overall net movement of particles is from L to R.

Part b: Net mass transfer at instant A

The molar transfer rates alone do not determine the direction of net mass transfer.

Each mole of methane has four times the mass of a mole of helium.

Using \(\dot m=Mr\), the ratio of the mass-transfer magnitudes is:

\[ \begin{aligned} \frac{\dot m_{\mathrm{He}}} {\dot m_{\mathrm{CH_4}}} &=\frac{4.00}{16.0}(1.60)\\ &=0.400 \end{aligned} \]

Thus, the mass of methane moving net from R to L per second is 2.50 times the mass of helium moving net from L to R per second.

Net mass transfer is therefore from R to L.

This is possible because the two directions carry different molecular species.

More particles move one way, but more mass moves the other way.

Part c: Net particle transfer at instant B

At the later instant, the total pressures are:

\[ \begin{aligned} P_L&=58+30=88\ \mathrm{kPa}\\ P_R&=42+70=112\ \mathrm{kPa} \end{aligned} \]

The partial-pressure differences are now:

  • Helium: \(58-42=16\ \mathrm{kPa}\), driving net transfer from L to R.
  • Methane: \(70-30=40\ \mathrm{kPa}\), driving net transfer from R to L.

Compare their molar transfer rates:

\[ \begin{aligned} \frac{r_{\mathrm{He}}}{r_{\mathrm{CH_4}}} &=\frac{16}{40} \sqrt{\frac{16.0}{4.00}}\\ &=0.400(2.00)\\ &=0.800 \end{aligned} \]

Now the methane transfer rate is greater.

For every 1.00 mole of methane transferred net from R to L, only 0.800 mol of helium is transferred net from L to R.

The overall net particle transfer is from R to L.

Notice that helium and methane haven’t reversed their individual net directions. Only the balance between their competing transfers has changed.

Part d: Assessing the student’s prediction

The student’s prediction is incorrect at instant A but correct at instant B.

The mistake is assuming that total pressure alone determines the direction of molecular transfer through this particular opening.

At instant A, helium’s much higher characteristic molecular speed is enough to make its net transfer dominate, even though methane has the larger partial-pressure difference.

As time passes, helium’s partial-pressure imbalance shrinks more rapidly. Eventually, methane’s opposing transfer becomes dominant.

The total-pressure difference is therefore not sufficient to predict the direction of the net particle transfer.

This doesn’t mean total pressure is irrelevant or that ordinary gas flow always behaves this way.

The result depends on the assumed free-molecular regime, the gas species, their partial pressures, and the absence of bulk-flow behaviour.

Part e: Final equilibrium

At equilibrium, each gas must have the same partial pressure in both chambers.

Otherwise, that gas would still have an unequal rate of crossing in the two directions.

Because the chambers have equal volumes, equal temperatures, and no gas is lost from the system, the original amount of each gas becomes equally distributed between them.

Initially, helium contributes \(100\ \mathrm{kPa}\) in one chamber and zero in the other.

Its final partial pressure in each chamber is therefore:

\[ p_{\mathrm{He}}=\frac{100}{2} =50\ \mathrm{kPa} \]

The same applies to methane:

\[ p_{\mathrm{CH_4}}=\frac{100}{2} =50\ \mathrm{kPa} \]

So each chamber reaches:

\[ P=50+50=100\ \mathrm{kPa} \]

At this point, helium and methane particles still cross the opening in both directions.

However, for each gas, the left-to-right and right-to-left crossing rates are equal.

There is no net transfer of either species.

The deeper point is that a system can temporarily have net particle movement towards a region of higher total pressure while different gases are moving in opposite directions according to their own partial-pressure differences.

The system approaches equilibrium through the combined behaviour of both gases, not through a single rule based only on total pressure.

07What Graham’s law helps you understand next

Graham’s law connects the microscopic motion of gas particles to a measurable macroscopic result: how many particles escape through an opening each second.

The practical decision is to identify the transport mechanism first. If you’re dealing with collision-free molecular effusion at equal temperature and pressure, molar mass gives a direct rate comparison. If partial pressures differ, include them. If the gas is mixing through another gas, permeating a solid membrane, or flowing through a wide tube, reconsider the model.

That leads to the next useful concept: the behaviour of gas mixtures when different species move at different rates.

In particular, preferential effusion can change a mixture’s composition over time. Understanding that process brings together three Year 11 ideas you already know-moles, partial pressures, and conservation of matter-and shows why a gas mixture’s composition and total pressure don’t tell the whole story about how its particles move.