Battery Capacity and C-Rate: Understanding Charge and Energy
Learn how battery capacity, electrical energy, and C-rate describe different aspects of battery performance. Explore how discharge speed affects usable capacity, voltage, energy, and operating time through worked examples and hypothetical battery data.
Two rechargeable cells both have a rated capacity of 2.0 Ah. One has a nominal voltage of 3.7 V, while the other has a nominal voltage of 7.4 V.
Which one can deliver more electrical energy?
Before reading on, make a prediction. If their capacities are identical, is their stored energy also identical?
No. The second cell has approximately twice the nominal energy:
- First cell: \(3.7 \times 2.0 = 7.4\text{ Wh}\)
- Second cell: \(7.4 \times 2.0 = 14.8\text{ Wh}\)
Both can deliver the same quantity of electrical charge under their rated conditions, but they do not deliver the same amount of energy.
There is another complication. Even if you know a battery’s capacity and voltage, you still cannot reliably predict how long it will operate without knowing how quickly it is being discharged.
This is where battery capacity, energy, and C-rate become important.
Syllabus scope: This guide assumes the Year 12 Applying chemical ideas foundation in the NSW Chemistry 11-12 Syllabus (2025), particularly galvanic cells, redox reactions, and standard reduction potentials. The quantitative treatment of battery capacity and C-rate goes beyond the required syllabus content. It is extension material, not an additional HSC assessment requirement. Year 12 identifies the assumed background knowledge, rather than an assessment expectation. The 2025 syllabus is scheduled for implementation from 2028. NESA syllabus information.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
01What does a galvanic cell actually tell us?
You already know that a galvanic cell converts chemical energy into electrical energy through a spontaneous redox reaction.
Consider a zinc-copper galvanic cell.
At the zinc electrode, oxidation occurs:
\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]
At the copper electrode, reduction occurs:
\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]
The electrons travel through the external circuit from the zinc electrode (anode) towards the copper electrode (cathode).
The standard cell potential is calculated using the standard reduction potentials:
\[ E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{cathode}} - E^\circ_{\mathrm{anode}} \]
A positive standard cell potential indicates that the overall reaction is spontaneous under standard conditions.
This tells us something important about the battery: its chemical reaction can produce an electrical potential difference.
However, it does not tell us how much charge the battery can deliver.
That distinction is the starting point for understanding battery capacity.
Voltage describes energy per unit charge
Electrical potential difference is measured in volts.
One volt is equivalent to one joule of energy per coulomb of charge:
\[ 1\text{ V}=1\text{ J C}^{-1} \]
In other words, voltage tells us how much electrical energy can be transferred per unit of charge.
The connection to your existing chemistry knowledge is the Gibbs free energy equation:
\[ \Delta G^\circ=-nFE^\circ_{\mathrm{cell}} \]
Where:
- \(\Delta G^\circ\) is the standard Gibbs free energy change per mole of reaction, in J mol\(^{-1}\).
- \(n\) is the number of moles of electrons transferred per mole of reaction, as determined by the balanced reaction.
- \(F\) is the Faraday constant, approximately \(96\,485\text{ C mol}^{-1}\).
- \(E^\circ_{\mathrm{cell}}\) is the standard cell potential, in volts.
This equation connects the energy available from a redox reaction to the electrical potential it produces.
Notice what is missing: the total amount of reactant available in the battery.
A cell potential describes the energy available per unit of charge. It does not tell us how much total charge can pass through the circuit before the available reactants or operating limits prevent further discharge.
The amount of reactant determines theoretical charge capacity
Return to the zinc-copper reaction.
For every mole of zinc that reacts, two moles of electrons are transferred.
If the cell contains enough reactants for 0.010 mol of the overall reaction, the total amount of electrons available is:
\[ n_e=2\times0.010=0.020\text{ mol} \]
The total theoretical charge is:
\[ q=n_eF \]
\[ q=0.020\times96\,485 \]
\[ q=1929.7\text{ C} \]
This is the theoretical charge available if the reaction proceeds completely and all the electrons are transferred through the external circuit.
The important idea is that increasing the amount of available reacting material increases the theoretical charge capacity.
If we doubled the amount of active material while maintaining the same chemical conditions, the theoretical charge would double. The standard cell potential would not.
The cell would have more total chemical material available to drive electron transfer, but the energy available per coulomb would remain unchanged.
This is why voltage and capacity must be treated as separate properties.
02Battery capacity: how much charge can be delivered?
Imagine a water tank.
Its capacity tells you how much water it can supply. It does not tell you how quickly the water flows or how much useful work the water can perform.
A battery has a similar distinction:
- Capacity describes the quantity of electrical charge it can deliver.
- Current describes how quickly that charge flows.
- Voltage describes the energy transferred per unit of charge.
The analogy is useful, but remember that a battery is not literally a tank of stored electrons. Its electrical output comes from chemical reactions occurring within the cell.
Ampere-hours
Battery capacity is commonly expressed in ampere-hours (Ah).
One ampere-hour is the amount of charge delivered by a current of one ampere flowing for one hour.
\[ 1\text{ Ah}=3600\text{ C} \]
For a constant discharge current:
\[ Q=It \]
Where:
- \(Q\) is the delivered capacity in Ah.
- \(I\) is the discharge current in amperes (A).
- \(t\) is the discharge time in hours (h).
For example, if a battery supplies a constant current of 2 A for three hours:
\[ Q=2\times3=6\text{ Ah} \]
The battery has delivered 6 Ah of electrical charge.
For a changing current, the capacity is found by adding the charge delivered over each time interval. In continuous form, this is the integral of current over time.
Importantly, a battery’s rated capacity is not necessarily the amount it will deliver under every operating condition.
Manufacturers specify capacity under particular testing conditions, including a discharge rate and a lower voltage limit called the cutoff voltage. Temperature, charging history, and battery age can also affect the measured result.
This means that a battery labelled 2.0 Ah might deliver less than 2.0 Ah when discharged under demanding conditions.
03Energy: how much electrical work can the battery deliver?
Now consider two batteries with the same capacity but different voltages.
Both deliver 2 Ah, but one maintains an average voltage of 3.6 V while the other maintains an average voltage of 7.2 V.
Which delivers more electrical energy?
The second battery delivers approximately twice as much.
Electrical energy depends on both the amount of charge transferred and the voltage across which it is transferred.
The relevant equation is:
\[ W=VQ \]
For a real battery, however, voltage changes during discharge. A more accurate expression is:
\[ W=\int V I\,dt \]
Where:
- \(W\) is electrical energy delivered, in joules or watt-hours.
- \(V\) is the instantaneous terminal voltage, in volts.
- \(I\) is the instantaneous current, in amperes.
- \(t\) is time.
Battery energy is commonly expressed in watt-hours (Wh).
If we know the average discharge voltage, we can use:
\[ W_{\mathrm{Wh}}\approx V_{\mathrm{avg}}Q_{\mathrm{Ah}} \]
This is a useful approximation when working with measured battery data.
For example, a battery delivering 2 Ah at an average voltage of 3.6 V supplies approximately:
\[ W=3.6\times2=7.2\text{ Wh} \]
Since one watt-hour is equal to 3600 joules:
\[ W=7.2\times3600=25\,920\text{ J} \]
The battery has delivered approximately 25.9 kJ of electrical energy.
Nominal energy versus actual delivered energy
Battery specifications often quote nominal voltage rather than the average voltage across a complete discharge.
This gives a convenient estimate:
\[ W_{\mathrm{nom}}\approx V_{\mathrm{nom}}Q_{\mathrm{rated}} \]
However, nominal energy is not necessarily the energy that will be delivered in practice.
The terminal voltage changes as the battery discharges. It also changes with current and other operating conditions.
Consequently, two batteries with identical nominal energy ratings can deliver different amounts of usable electrical energy.
This distinction becomes particularly important when comparing batteries for electric vehicles, laptops, and other devices.
04C-rate: how quickly is the battery being discharged?
Suppose you have two batteries:
- Battery A has a capacity of 2 Ah.
- Battery B has a capacity of 8 Ah.
Both are discharged at a current of 2 A.
Will they discharge at the same relative rate?
No. Battery A is supplying current equal to its entire rated capacity in one hour, whereas Battery B is supplying only one-quarter of its rated capacity each hour.
We describe this using the C-rate.
The C-rate is the discharge current divided by the battery’s rated capacity:
\[ r=\frac{I}{Q_{\mathrm{rated}}} \]
Where:
- \(r\) is the C-rate, expressed using the conventional notation \(1C\), \(2C\), and so on.
- \(I\) is the discharge current in amperes.
- \(Q_{\mathrm{rated}}\) is the rated capacity in ampere-hours.
The resulting numerical rate has units of h\(^{-1}\).
For Battery A:
\[ r=\frac{2}{2}=1C \]
For Battery B:
\[ r=\frac{2}{8}=0.25C \]
Battery A is therefore operating at a higher relative discharge rate.
What do the common C-rates mean?
| C-rate | Current for a 2 Ah battery | Ideal discharge time |
|---|---|---|
| 0.1C | 0.2 A | 10 hours |
| 0.25C | 0.5 A | 4 hours |
| 0.5C | 1.0 A | 2 hours |
| 1C | 2.0 A | 1 hour |
| 2C | 4.0 A | 30 minutes |
| 5C | 10.0 A | 12 minutes |
The ideal discharge time is calculated using:
\[ t_{\mathrm{ideal}}=\frac{1}{r} \]
This assumes that the battery delivers its full rated capacity at a constant current.
It is a useful starting estimate, not a guarantee of actual operating time.
A 2 Ah battery discharged at 2C is being asked to supply 4 A. The label does not mean that its capacity has doubled, or that it will necessarily deliver its full 2 Ah in exactly 30 minutes.
Also, be careful with the notation. The C in a label such as 2C refers to the conventional C-rate. The coulomb, also written C, is a separate SI unit of electrical charge.
Worked example: calculate current and ideal discharge time
A rechargeable battery has a rated capacity of 3.0 Ah and a nominal voltage of 3.7 V. It is discharged at 0.5C.
Calculate its discharge current, ideal operating time, and nominal energy.
Step 1
Rearrange the C-rate equation:
\[ I=rQ_{\mathrm{rated}} \]
Substitute the given values:
\[ I=0.5\times3.0 \]
\[ \boxed{I=1.5\text{ A}} \]
The battery supplies 1.5 coulombs of charge per second.
Step 2
Assuming the full rated capacity is delivered:
\[ t=\frac{Q}{I} \]
\[ t=\frac{3.0}{1.5} \]
\[ \boxed{t=2.0\text{ h}} \]
At 0.5C, the battery is expected to discharge over approximately two hours under the ideal assumption.
Step 3
\[ W_{\mathrm{nom}}\approx V_{\mathrm{nom}}Q_{\mathrm{rated}} \]
\[ W_{\mathrm{nom}}\approx3.7\times3.0 \]
\[ \boxed{W_{\mathrm{nom}}\approx11.1\text{ Wh}} \]
The battery has a nominal energy rating of 11.1 Wh.
Notice that we needed three different calculations to describe three different properties of the same battery.
05What actually happens when the C-rate increases?
So far, the ideal model suggests that increasing the C-rate simply reduces the operating time.
For example, doubling the current should halve the discharge time.
But real batteries do not always behave this neatly.
Consider what happens inside a rechargeable cell when a large current is demanded.
In a typical lithium-ion battery, lithium ions move through the electrolyte between the negative and positive electrodes during discharge. Electrons travel through the external circuit and power the connected device.
Both processes must occur quickly enough to support the requested current.
The role of internal resistance and polarisation
A battery is not a perfect voltage source.
It has internal resistance, and its electrochemical processes cannot respond to every increase in current without some voltage loss.
A simple first approximation is:
\[ V_{\mathrm{terminal}}\approx E_{\mathrm{rest}}-Ir_{\mathrm{int}} \]
Where:
- \(V_{\mathrm{terminal}}\) is the voltage measured across the battery while discharging.
- \(E_{\mathrm{rest}}\) is the approximate open-circuit voltage before the load is connected.
- \(I\) is the discharge current.
- \(r_{\mathrm{int}}\) is the internal resistance of the battery.
This simplified model shows why a higher current produces a larger voltage drop across the battery’s internal resistance.
Real cells are more complicated. They also experience polarisation associated with charge transfer and the movement of ions through the electrolyte and electrode materials.
The relative importance of these effects depends on battery chemistry, construction, temperature, and state of charge. The equation above is therefore an explanatory approximation, not a complete battery model.
Why does this reduce measured capacity?
Imagine a battery that is discharged until its terminal voltage reaches 3.0 V.
This minimum permitted voltage is the cutoff voltage.
At a low discharge current, the battery might maintain a relatively high terminal voltage for longer.
At a high discharge current, internal voltage losses and polarisation become more significant. The terminal voltage can reach 3.0 V earlier, even though some electrochemically active material remains.
The battery is then considered discharged under that particular test condition.
This means the measured capacity can be lower at a higher discharge rate.
Some of the apparent capacity loss may be recoverable when the battery rests or is discharged more slowly. However, voltage recovery does not mean that the battery has been recharged.
The important point is that battery capacity is an operational measurement. It depends on how the battery is tested, not just on the chemical materials inside it.
The US Department of Defense’s battery specification explicitly identifies cutoff voltage, discharge rate, temperature, charging method, and battery age as factors affecting measured capacity. Battery specification.
06Interpreting a hypothetical battery dataset
Let’s bring the three quantities together.
Consider a hypothetical rechargeable cell with these specifications:
- Rated capacity: 2.00 Ah.
- Nominal voltage: 3.70 V.
- Cutoff voltage: 3.00 V.
- Test temperature: 25 °C.
- Initial state: fully charged.
The same cell is tested three times under different constant-current discharge conditions.
The following results are hypothetical and are designed to demonstrate how battery performance changes with discharge rate.
| Discharge rate | Current | Delivered capacity | Average voltage | Discharge time | Delivered energy |
|---|---|---|---|---|---|
| 0.5C | 1.00 A | 1.96 Ah | 3.62 V | 1.96 h | 7.10 Wh |
| 1.0C | 2.00 A | 1.90 Ah | 3.55 V | 0.95 h | 6.75 Wh |
| 2.0C | 4.00 A | 1.72 Ah | 3.40 V | 0.43 h | 5.85 Wh |
Each row represents a different discharge test. The average voltage and delivered energy are calculated from the voltage and current recorded during that test.
What does the dataset tell us?
Start with the current.
The rated capacity is 2.00 Ah, so the currents are:
- At 0.5C: \(0.5\times2.00=1.00\text{ A}\).
- At 1.0C: \(1.0\times2.00=2.00\text{ A}\).
- At 2.0C: \(2.0\times2.00=4.00\text{ A}\).
The C-rate determines the requested current relative to the rated capacity.
However, look at the delivered capacity.
At 0.5C, the battery delivers 1.96 Ah. At 2.0C, it delivers only 1.72 Ah.
The faster discharge has reduced the measured capacity.
Now consider the average voltage. It has also decreased, from 3.62 V to 3.40 V.
Both changes affect the total energy delivered.
At 0.5C:
\[ W\approx3.62\times1.96=7.10\text{ Wh} \]
At 2.0C:
\[ W\approx3.40\times1.72=5.85\text{ Wh} \]
The higher discharge rate has reduced both the amount of charge delivered and the energy transferred per unit of charge.
This is why the energy reduction is greater than the capacity reduction alone would suggest.
Worked example: calculate actual operating time and energy at 2C
Use the 2.0C row of the dataset to calculate the actual discharge current, operating time, and delivered energy.
Step 1
The rated capacity is 2.00 Ah.
\[ I=rQ_{\mathrm{rated}} \]
\[ I=2.0\times2.00 \]
\[ \boxed{I=4.00\text{ A}} \]
Step 2
The battery delivers 1.72 Ah before reaching its cutoff voltage.
\[ t=\frac{Q}{I} \]
\[ t=\frac{1.72}{4.00} \]
\[ t=0.430\text{ h} \]
Converting into minutes:
\[ t=0.430\times60 \]
\[ \boxed{t=25.8\text{ min}} \]
The actual operating time is 25.8 minutes.
Notice that the ideal prediction at 2C was 30 minutes. The actual discharge ends earlier because the cell delivers less than its rated capacity at this rate.
Step 3
The average terminal voltage is 3.40 V.
\[ W\approx V_{\mathrm{avg}}Q \]
\[ W\approx3.40\times1.72 \]
\[ \boxed{W\approx5.85\text{ Wh}} \]
Converting into joules:
\[ W=5.85\times3600 \]
\[ \boxed{W\approx21\,100\text{ J}} \]
The battery delivers approximately 21.1 kJ of electrical energy before reaching its cutoff voltage.
Step 4
The nominal energy is:
\[ W_{\mathrm{nom}}=3.70\times2.00 \]
\[ W_{\mathrm{nom}}=7.40\text{ Wh} \]
The measured energy of 5.85 Wh is lower than this nominal estimate.
That difference is consistent with the reduced capacity and lower average terminal voltage during the faster discharge.
The key lesson is that a battery’s nominal specifications do not guarantee its actual performance under every load.
07Capacity, energy, C-rate, and power are not interchangeable
There is one final distinction worth making.
Power is the rate at which electrical energy is transferred.
It is calculated using:
\[ P=VI \]
Where:
- \(P\) is electrical power in watts (W).
- \(V\) is terminal voltage in volts (V).
- \(I\) is current in amperes (A).
C-rate and power are related through current, but they describe different things.
Consider two batteries, each with a rated capacity of 2 Ah.
| Property | Battery A | Battery B |
|---|---|---|
| Rated capacity | 2 Ah | 2 Ah |
| Nominal voltage | 3.7 V | 7.4 V |
| Current at 1C | 2 A | 2 A |
| Approximate nominal power at 1C | 7.4 W | 14.8 W |
| Approximate nominal energy | 7.4 Wh | 14.8 Wh |
Both batteries operate at 1C when supplying 2 A.
However, Battery B has approximately twice the nominal power and energy.
The C-rate alone cannot tell you how much power a battery can supply. You also need its voltage and its permitted operating current.
Similarly, a high capacity does not automatically mean that a battery can safely deliver a high current.
A battery designed for high energy storage may have different discharge limitations from one designed for high power output.
This is why battery specifications commonly include maximum continuous discharge current, maximum pulse current, operating temperature limits, and voltage limits alongside capacity.
08Questions and solutions
Question 1
A rechargeable battery has a rated capacity of 8.0 Ah. It is discharged at a constant rate of 0.25C.
Calculate:
(a) The discharge current.
(b) The ideal discharge time, assuming the battery delivers its full rated capacity.
Solution 1
(a) The discharge current is 2.0 A.
Using the C-rate equation:
\[ I=rQ_{\mathrm{rated}} \]
\[ I=0.25\times8.0 \]
\[ \boxed{I=2.0\text{ A}} \]
The battery supplies a current of 2.0 A.
(b) The ideal discharge time is 4.0 hours.
Using:
\[ t=\frac{Q}{I} \]
\[ t=\frac{8.0}{2.0} \]
\[ \boxed{t=4.0\text{ h}} \]
This is the ideal operating time if the entire rated capacity is delivered at a constant current. An actual battery may discharge more quickly if its accessible capacity decreases under the test conditions.
Question 2
Use the hypothetical battery dataset in Section 6.
Compare the discharge tests at 0.5C and 2.0C.
(a) Calculate the percentage decrease in delivered charge capacity when the discharge rate increases from 0.5C to 2.0C.
(b) Calculate the percentage decrease in delivered electrical energy.
(c) Explain why the percentage decrease in energy is greater than the percentage decrease in capacity.
Solution 2
(a) The delivered charge capacity decreases by approximately 12.2%.
The capacity at 0.5C is 1.96 Ah, while the capacity at 2.0C is 1.72 Ah.
The absolute decrease is:
\[ \Delta Q=1.96-1.72 \]
\[ \Delta Q=0.24\text{ Ah} \]
The percentage decrease is calculated relative to the original 0.5C result:
\[ \%\text{ decrease} = \frac{0.24}{1.96}\times100 \]
\[ \boxed{12.2\%} \]
The faster discharge reduces the measured charge capacity by approximately 12.2%.
(b) The delivered electrical energy decreases by approximately 17.6%.
The energy at 0.5C is 7.10 Wh, while the energy at 2.0C is 5.85 Wh.
\[ \Delta W=7.10-5.85 \]
\[ \Delta W=1.25\text{ Wh} \]
Therefore:
\[ \%\text{ decrease} = \frac{1.25}{7.10}\times100 \]
\[ \boxed{17.6\%} \]
(c) Energy decreases more because both delivered capacity and average voltage decrease.
The energy delivered depends on:
\[ W\approx V_{\mathrm{avg}}Q \]
When the discharge rate increases:
- Capacity decreases from 1.96 Ah to 1.72 Ah.
- Average voltage decreases from 3.62 V to 3.40 V.
The battery therefore delivers less charge, and each unit of charge transfers less energy on average.
A common mistake is to attribute the entire energy reduction to the loss of capacity. That ignores the accompanying decrease in terminal voltage.
Both effects contribute to the reduction in delivered energy.
Question 3
A hypothetical galvanic cell has an overall reaction that transfers three moles of electrons for every mole of reaction.
The limiting reactant allows 0.00400 mol of the overall reaction to occur.
The standard cell potential is 1.25 V.
Assume complete utilisation of the limiting reactant and standard conditions.
(a) Calculate the theoretical charge capacity in ampere-hours.
(b) Calculate the maximum electrical energy available in watt-hours.
(c) The cell is scaled up so that twice the original amount of each reactant is available. The electrolyte volume is also doubled, maintaining the original concentrations. Explain what happens to the theoretical capacity, total electrical energy, and standard cell potential.
Solution 3
(a) The theoretical charge capacity is approximately 0.322 Ah.
First, calculate the total moles of electrons transferred.
Each mole of reaction transfers three moles of electrons.
\[ n_e=3\times0.00400 \]
\[ n_e=0.0120\text{ mol} \]
Use Faraday’s law:
\[ q=n_eF \]
\[ q=0.0120\times96\,485 \]
\[ q=1157.82\text{ C} \]
Convert coulombs into ampere-hours:
\[ Q_{\mathrm{Ah}}=\frac{1157.82}{3600} \]
\[ \boxed{Q_{\mathrm{Ah}}=0.322\text{ Ah}} \]
This is the theoretical charge capacity, assuming every available electron contributes to the external circuit.
(b) The maximum electrical energy is approximately 0.402 Wh.
Electrical energy is the product of charge and potential difference.
\[ W=qE^\circ_{\mathrm{cell}} \]
\[ W=1157.82\times1.25 \]
\[ W=1447.28\text{ J} \]
Convert to watt-hours:
\[ W=\frac{1447.28}{3600} \]
\[ \boxed{W=0.402\text{ Wh}} \]
This represents the ideal maximum electrical work under the stated standard-state assumptions.
Actual delivered energy may be lower because the cell potential changes during discharge and practical cells experience voltage losses.
(c) The theoretical capacity and total electrical energy double, but the standard cell potential remains 1.25 V.
Doubling the amount of available reactants doubles the number of moles of electrons that can be transferred.
Therefore:
\[ Q_{\mathrm{new}}=2\times0.322 \]
\[ \boxed{Q_{\mathrm{new}}=0.644\text{ Ah}} \]
The total ideal electrical energy also doubles:
\[ W_{\mathrm{new}}=2\times0.402 \]
\[ \boxed{W_{\mathrm{new}}=0.804\text{ Wh}} \]
However, the standard cell potential remains unchanged at 1.25 V.
This is because standard cell potential describes the energy available per unit of charge under standard conditions. It does not increase simply because more reactants are available.
The tempting mistake is to assume that doubling the reaction amount doubles every electrical property. It doubles the total charge and energy, but not the potential difference.
Question 4
A rechargeable cell is discharged at 2.0C until its terminal voltage reaches the specified cutoff voltage of 3.00 V.
At this point, it has delivered 1.72 Ah.
The external load is disconnected, and the cell is allowed to rest for 20 minutes. Its open-circuit voltage then rises to 3.24 V.
A student claims:
“The battery has regained 0.24 V worth of charge during the resting period, so its capacity must have increased.”
Evaluate this claim.
Your answer should explain:
(a) Whether the battery has been recharged.
(b) Why its voltage increases after the load is disconnected.
(c) Whether additional charge could be delivered if the cell were discharged again at a lower current.
Solution 4
The battery has not been recharged. Its voltage has recovered because the voltage losses associated with discharge have partially relaxed.
(a) The battery has not been recharged.
During the 2.0C discharge, the battery delivered 1.72 Ah.
The external circuit was then disconnected.
No charging current was supplied, so the battery did not receive electrical energy from an external source.
An increase in terminal voltage does not, by itself, demonstrate that charge has been restored.
Voltage measures electrical potential difference, not the quantity of charge stored.
(b) The voltage increases because internal voltage losses and polarisation relax after the load is removed.
While the battery was discharging, current flowed through its internal resistance.
This produced a voltage drop within the cell. Polarisation and concentration gradients also contributed to the difference between its operating terminal voltage and its open-circuit voltage.
When the load was disconnected, the discharge current became zero.
The internal resistance drop disappeared, and electrochemical conditions began to relax towards equilibrium.
Consequently, the measured open-circuit voltage increased from 3.00 V to 3.24 V.
This is known as voltage recovery or voltage relaxation.
It does not mean that the battery has gained 0.24 V worth of charge.
(c) The cell may deliver additional capacity when discharged again at a lower current.
At the higher discharge rate, voltage losses can cause the cell to reach its cutoff voltage before all potentially available electrochemical material has been utilised.
After resting, a lower discharge current may produce smaller internal voltage losses.
The cell may therefore supply additional charge before reaching the cutoff voltage again.
However, the voltage increase alone cannot tell us exactly how much additional capacity is available.
A further controlled discharge test would be required to measure it.
The distinction is between recovering some access to existing electrochemical capacity and actually recharging the battery. These are not the same process.
Question 5
Two hypothetical rechargeable battery packs, A and B, are designed to supply the same electrical device.
Their specifications are:
| Property | Pack A | Pack B |
|---|---|---|
| Nominal voltage | 3.60 V | 7.20 V |
| Rated capacity | 2.00 Ah | 1.00 Ah |
| Nominal energy | 7.20 Wh | 7.20 Wh |
Both packs are initially fully charged at 25 °C.
Each pack supplies a regulated 7.20 W load through an ideal power converter. Assume that the converter has 100% efficiency, so the battery supplies exactly 7.20 W throughout the discharge.
The discharge ends when each pack reaches its specified cutoff voltage.
Testing produces the following results:
| Measured property | Pack A | Pack B |
|---|---|---|
| Initial terminal voltage | 3.60 V | 7.20 V |
| Final terminal voltage | 3.00 V | 6.20 V |
| Delivered capacity | 1.64 Ah | 0.88 Ah |
| Delivered energy | 5.35 Wh | 6.25 Wh |
A student makes the following argument:
“Both packs have the same nominal energy, so they must run the device for the same amount of time. They also both begin at 1C, so their discharge rates are identical throughout the test.”
Evaluate this argument.
Your response must:
(a) Verify the nominal energy of both packs and calculate their initial C-rates.
(b) Calculate the actual operating time of each pack.
(c) Calculate the discharge current and instantaneous C-rate at the cutoff voltage of each pack.
(d) Explain why the packs do not necessarily have the same operating time, despite having the same nominal energy and initial C-rate.
Solution 5
Pack B operates the device for longer: approximately 52.1 minutes compared with 44.6 minutes for Pack A. The student’s argument is incorrect because nominal energy and initial C-rate do not guarantee identical discharge performance.
The crucial issue is that the packs are supplying constant power while their terminal voltages change.
This means their discharge currents are not constant.
(a) Both packs have a nominal energy of 7.20 Wh and an initial C-rate of 1C.
Calculate the nominal energy of Pack A:
\[ W_{\mathrm{nom,A}}=3.60\times2.00 \]
\[ \boxed{W_{\mathrm{nom,A}}=7.20\text{ Wh}} \]
For Pack B:
\[ W_{\mathrm{nom,B}}=7.20\times1.00 \]
\[ \boxed{W_{\mathrm{nom,B}}=7.20\text{ Wh}} \]
Now calculate their initial discharge currents.
Since power is constant:
\[ P=VI \]
Rearranging:
\[ I=\frac{P}{V} \]
For Pack A:
\[ I_A=\frac{7.20}{3.60}=2.00\text{ A} \]
Its initial C-rate is:
\[ r_A=\frac{2.00}{2.00} \]
\[ \boxed{r_A=1.00C} \]
For Pack B:
\[ I_B=\frac{7.20}{7.20}=1.00\text{ A} \]
Its initial C-rate is:
\[ r_B=\frac{1.00}{1.00} \]
\[ \boxed{r_B=1.00C} \]
The packs therefore have identical nominal energy and identical initial C-rates.
So far, the student’s calculations are correct.
The mistake is assuming these values remain sufficient to predict the entire discharge.
(b) Pack A operates for approximately 44.6 minutes, while Pack B operates for approximately 52.1 minutes.
The load receives 7.20 W throughout the test.
Using:
\[ t=\frac{W}{P} \]
For Pack A:
\[ t_A=\frac{5.35}{7.20} \]
\[ t_A=0.7431\text{ h} \]
Converting to minutes:
\[ t_A=0.7431\times60 \]
\[ \boxed{t_A=44.6\text{ min}} \]
For Pack B:
\[ t_B=\frac{6.25}{7.20} \]
\[ t_B=0.8681\text{ h} \]
\[ t_B=0.8681\times60 \]
\[ \boxed{t_B=52.1\text{ min}} \]
Pack B operates for approximately 7.5 minutes longer.
The reason is that it delivers more actual electrical energy before reaching its cutoff voltage.
(c) The instantaneous C-rates increase during discharge for both packs.
This is the most important part of the problem.
The load requires constant power, so:
\[ I=\frac{P}{V} \]
As terminal voltage decreases, current must increase to maintain the same power.
For Pack A, the cutoff voltage is 3.00 V.
Its discharge current at cutoff is:
\[ I_A=\frac{7.20}{3.00} \]
\[ I_A=2.40\text{ A} \]
Its instantaneous C-rate is:
\[ r_A=\frac{2.40}{2.00} \]
\[ \boxed{r_A=1.20C} \]
For Pack B, the cutoff voltage is 6.20 V.
Its discharge current at cutoff is:
\[ I_B=\frac{7.20}{6.20} \]
\[ I_B=1.161\text{ A} \]
Its instantaneous C-rate is:
\[ r_B=\frac{1.161}{1.00} \]
\[ \boxed{r_B\approx1.16C} \]
Neither pack remains at 1C throughout the discharge.
Both start at 1C and increase to a higher instantaneous discharge rate as their terminal voltages fall.
(d) Equal nominal energy and initial C-rate do not guarantee equal usable energy or operating time.
The nominal energy calculation uses:
\[ W_{\mathrm{nom}}\approx V_{\mathrm{nom}}Q_{\mathrm{rated}} \]
This is an estimate based on nominal voltage and rated capacity.
It does not account for the actual voltage profile, the capacity accessible under the changing discharge current, or the cutoff condition.
Compare the fraction of nominal energy delivered by each pack.
For Pack A:
\[ \frac{5.35}{7.20}\times100 = 74.3\% \]
For Pack B:
\[ \frac{6.25}{7.20}\times100 = 86.8\% \]
Pack B delivers a greater proportion of its nominal energy under the specified operating conditions.
The reason cannot be established from nominal voltage and capacity alone. The measured results reflect differences in the packs’ voltage profiles and rate-dependent discharge performance.
There is another subtle point.
For a constant-power load, the instantaneous C-rate can be expressed as:
\[ r_{\mathrm{inst}}= \frac{P}{VQ_{\mathrm{rated}}} \]
As the terminal voltage decreases, the instantaneous C-rate increases.
This means the battery is progressively being asked to supply more current relative to its rated capacity. Its voltage losses and electrochemical limitations can therefore become increasingly important.
The tempting conclusion is that equal nominal watt-hours must produce equal operating times. That would be true if both packs could deliver all their nominal energy to the load.
The measurements show that they cannot.
The final decision: Pack B is the better choice for this particular operating condition because it delivers more usable energy before reaching its cutoff voltage. However, the data alone do not establish which pack has the better cycle life, safety characteristics, or maximum permitted discharge rate.
09Where to take this concept next
Battery capacity and C-rate become much more useful when you connect them to the mechanisms responsible for voltage loss.
You can already see that a battery’s internal resistance and electrochemical limitations affect how much energy it can deliver under load.
The next useful concept is electrochemical impedance spectroscopy (EIS), which investigates the electrical response of an electrochemical cell and helps distinguish contributions from resistance and interfacial processes.
Read Electrochemical Impedance Spectroscopy: Interpreting EIS Data to explore how those internal processes can be investigated.
10Technical references
The following sources support the electrochemical relationships, battery-performance definitions, and models used in this extension guide.
NSW Education Standards Authority (NESA) – Chemistry 11-12 Syllabus (2025). Syllabus structure and implementation dates.
OpenStax, Chemistry 2e – Potential, Free Energy, and Equilibrium. The relationship between standard cell potential, Gibbs free energy, and electron transfer.
National Renewable Energy Laboratory (NREL) – DiOrio et al., Technoeconomic Modeling of Battery Energy Storage in SAM (2015). Battery voltage models, C-rate, state of charge, and voltage losses during charging and discharging.
Idaho National Engineering and Environmental Laboratory – Uncertainty Study of INEEL EST Laboratory Battery Testing Systems, Volume 1 (2001). Definitions of battery capacity, power, and energy in terms of measured current, voltage, and time.
US Defense Logistics Agency – MIL-PRF-32565C, Amendment 2 (2022). Technical definitions of ampere-hour capacity, C-rate, and cutoff voltage, including factors affecting measured battery capacity.