How to Combine Uncertainties When Multiplying Measurements
Learn why percentage uncertainties add when measured quantities are multiplied, how powers affect the result, and how to calculate absolute uncertainty using worked HSC Physics examples and practice questions.
A student measures the length and width of a rectangular sheet, then multiplies them to calculate its area. Both measurements have uncertainty. So how much uncertainty should the calculated area have?
You might be tempted to add the two uncertainties directly. That gives the wrong result because the measurements have different units and scales. A better approach is to calculate their percentage uncertainties first.
## The rule: multiplying measured quantities
When you multiply two measured quantities, **add their percentage uncertainties**.
For two positive measurements, \(A\) and \(B\), with absolute uncertainties \(\Delta A\) and \(\Delta B\):
\[
\frac{\Delta Q}{Q}
\approx
\frac{\Delta A}{A}
+
\frac{\Delta B}{B}
\]
where \(Q=AB\).
Equivalently, using percentage uncertainties:
\[
\boxed{
\%\text{ uncertainty in }Q
=
\%\text{ uncertainty in }A
+
\%\text{ uncertainty in }B
}
\]
This is the usual maximum-uncertainty method taught for HSC Physics calculations involving multiplication and division.
Once you have the percentage uncertainty in the result, convert it back into an absolute uncertainty:
\[
\Delta Q
=
Q\times
\frac{\%\text{ uncertainty in }Q}{100}
\]
The important distinction is that you add percentage uncertainties, not absolute uncertainties.
## Why do percentage uncertainties add?
Imagine measuring a rectangle with a ruler.
You obtain:
- Length: \(20.0\pm0.2\text{ cm}\)
- Width: \(10.0\pm0.1\text{ cm}\)
The length uncertainty is \(0.2/20.0=1\%\). The width uncertainty is \(0.1/10.0=1\%\).
Both dimensions could be slightly larger than their measured values. If that happens, the calculated area increases because both factors in the multiplication increase.
The same applies in reverse: if both dimensions are smaller, the calculated area decreases.
[IMAGE: A rectangular sheet viewed from above, with horizontal length labelled 20.0 ± 0.2 cm and vertical width labelled 10.0 ± 0.1 cm. Show the measured central dimensions and subtle dashed outlines indicating the slightly larger and smaller possible rectangles. Include a small adjacent annotation showing that a 1% increase in each dimension produces approximately a 2% increase in area.]
The percentage uncertainties combine because each measurement contributes to the possible change in the product.
For small uncertainties, the combined percentage uncertainty is approximately the sum of the individual percentage uncertainties. This is a first-order approximation, which is why the rule uses the symbol \(\approx\).
### What does the uncertainty actually represent?
A measurement written as \(20.0\pm0.2\text{ cm}\) represents an interval from \(19.8\text{ cm}\) to \(20.2\text{ cm}\), assuming the stated uncertainty is a symmetric bound.
It does not mean that the actual length is necessarily \(20.0\text{ cm}\), nor does it mean that every value inside the interval is equally likely.
For the rectangle, the measured central area is:
\[
Q=20.0\times10.0=200.0\text{ cm}^2
\]
The maximum percentage uncertainty, using the usual HSC approximation, is:
\[
1\%+1\%=2\%
\]
Therefore:
\[
\Delta Q=200.0\times0.02
=4.0\text{ cm}^2
\]
The calculated area is:
\[
\boxed{Q=200\pm4\text{ cm}^2}
\]
This means the approximate result is reported with a 2% uncertainty.
Check the approximation against the actual measurement intervals
We can check how closely the percentage method matches the possible values of the area.
The length can lie between \(19.8\) and \(20.2\text{ cm}\), while the width can lie between \(9.9\) and \(10.1\text{ cm}\).
Because both dimensions are positive, the minimum and maximum areas are:
\[ \begin{aligned} Q_{\min}&=19.8\times9.9\\\ &=196.02\text{ cm}^2 \end{aligned} \]
\[ \begin{aligned} Q_{\max}&=20.2\times10.1\\\ &=204.02\text{ cm}^2 \end{aligned} \]
The exact interval is therefore:
\[ 196.02\leq Q\leq204.02\text{ cm}^2 \]
Compare this with the approximate result of \(200.0\pm4.0\text{ cm}^2\).
The exact lower limit is \(3.98\text{ cm}^2\) below the central value, and the upper limit is \(4.02\text{ cm}^2\) above it.
That’s extremely close to the symmetric uncertainty estimate of \(4.0\text{ cm}^2\).
For small uncertainties, the difference is usually negligible. This is why the percentage method works so well for typical HSC calculations.
01A practical method for combining uncertainties
When you encounter a multiplication question in an exam, follow this sequence.
| Step | What to do |
|---|---|
| 1 | Write the equation for the calculated quantity. |
| 2 | Identify the uncertainty convention being used. |
| 3 | Calculate the percentage uncertainty of each measured factor. |
| 4 | Add the percentage uncertainties. |
| 5 | Calculate the central value of the result. |
| 6 | Convert the combined percentage uncertainty into an absolute uncertainty. |
There are a few extra rules worth remembering.
What if a measured quantity is squared?
Suppose the equation contains:
\[ Q=A^2B \]
The percentage uncertainty in \(A\) must be counted twice.
The combined percentage uncertainty is:
\[ \boxed{ \%\Delta Q = 2(\%\Delta A)+\%\Delta B } \]
More generally, for positive measured quantities:
\[ Q=A^nB^m \]
the maximum percentage uncertainty is approximately:
\[ \%\Delta Q = |n|(\%\Delta A)+|m|(\%\Delta B) \]
This also applies when a measured quantity appears in a denominator.
For example:
\[ Q=\frac{A}{B^2} \]
The maximum percentage uncertainty is:
\[ \%\Delta Q = \%\Delta A+2(\%\Delta B) \]
The important idea is that each power tells you how strongly a measurement contributes to the calculated result.
Worked example: Calculate the uncertainty in momentum
A trolley has a measured mass of \(0.500\pm0.005\text{ kg}\) and travels at \(4.00\pm0.08\text{ m s}^{-1}\).
Calculate its momentum and the maximum percentage and absolute uncertainties.
Step 1: Write the equation.
Momentum is:
\[ p=mv \]
where:
- \(p\) is momentum in \(\mathrm{kg\\,m\\,s^{-1}}\);
- \(m\) is mass in kilograms;
- \(v\) is velocity in metres per second.
This is a multiplication, so we add the percentage uncertainties.
Step 2: Calculate the percentage uncertainty in mass.
\[ \%\Delta m = \frac{0.005}{0.500}\times100 =1.0\% \]
Step 3: Calculate the percentage uncertainty in velocity.
\[ \%\Delta v = \frac{0.08}{4.00}\times100 =2.0\% \]
Step 4: Add the percentage uncertainties.
\[ \begin{aligned} \%\Delta p &=1.0\%+2.0\%\\\ &=3.0\% \end{aligned} \]
Step 5: Calculate the central momentum.
\[ \begin{aligned} p&=mv\\\ &=0.500\times4.00\\\ &=2.00\text{ kg m s}^{-1} \end{aligned} \]
Step 6: Convert the percentage uncertainty into an absolute uncertainty.
\[ \begin{aligned} \Delta p &=2.00\times\frac{3.0}{100}\\\ &=0.060\text{ kg m s}^{-1} \end{aligned} \]
Therefore:
\[ \boxed{ p=(2.00\pm0.06)\text{ kg m s}^{-1} } \]
The calculated momentum has a maximum estimated percentage uncertainty of 3.0%.
Worked example: Calculate uncertainty in kinetic energy
A cricket ball has a measured mass of \(0.800\pm0.004\text{ kg}\) and a measured speed of \(6.00\pm0.12\text{ m s}^{-1}\).
Calculate its kinetic energy and the maximum percentage and absolute uncertainties.
Step 1: Write the equation.
Kinetic energy is:
\[ E_k=\frac12mv^2 \]
where:
- \(E_k\) is kinetic energy in joules (J);
- \(m\) is mass in kilograms;
- \(v\) is speed in metres per second.
Notice that speed is squared.
Step 2: Calculate the percentage uncertainty in mass.
\[ \begin{aligned} \%\Delta m &=\frac{0.004}{0.800}\times100\\\ &=0.5\% \end{aligned} \]
Step 3: Calculate the percentage uncertainty in speed.
\[ \begin{aligned} \%\Delta v &=\frac{0.12}{6.00}\times100\\\ &=2.0\% \end{aligned} \]
Step 4: Account for the squared speed.
Because the speed is raised to the power of two, its percentage uncertainty is multiplied by two.
\[ \begin{aligned} \%\Delta E_k &=\%\Delta m+2(\%\Delta v)\\\ &=0.5\%+2(2.0\%)\\\ &=4.5\% \end{aligned} \]
The constant \(\frac12\) contributes no uncertainty because it is exact.
Step 5: Calculate the central kinetic energy.
\[ \begin{aligned} E_k&=\frac12mv^2\\\ &=\frac12(0.800)(6.00)^2\\\ &=14.4\text{ J} \end{aligned} \]
Step 6: Calculate the absolute uncertainty.
\[ \begin{aligned} \Delta E_k &=14.4\times\frac{4.5}{100}\\\ &=0.648\text{ J} \end{aligned} \]
Rounding the uncertainty to two significant figures:
\[ \Delta E_k=0.65\text{ J} \]
Therefore:
\[ \boxed{ E_k=(14.40\pm0.65)\text{ J} } \]
The result has a maximum estimated percentage uncertainty of 4.5%.
Notice something important: the speed contributes 4.0 percentage points to the total uncertainty, while the mass contributes only 0.5 percentage points.
Improving the speed measurement would therefore have a much greater effect on the uncertainty in kinetic energy.
02Which uncertainty convention are you using?
So far, we’ve used the maximum-uncertainty convention. This is the usual approach for introductory HSC calculations unless a question specifies another convention.
However, not every uncertainty value represents a maximum possible deviation.
There are three ideas worth separating.
| Term | What it describes |
|---|---|
| Maximum uncertainty | An estimated bound on how far the measurement could deviate from its central value. |
| Standard uncertainty | An uncertainty expressed as a standard deviation. |
| Standard deviation | The spread of a collection of repeated measurements around their mean. |
Maximum uncertainty versus standard uncertainty
Suppose two independent measurements are:
\[ A=10.0\pm0.2 \]
\[ B=5.0\pm0.1 \]
Assume both measurements are positive.
Under the maximum-uncertainty convention:
\[ \%\Delta A=2\% \]
\[ \%\Delta B=2\% \]
Therefore:
\[ \%\Delta Q=2\%+2\%=4\% \]
However, if the uncertainties are explicitly given as independent standard uncertainties, the standard uncertainty of their product is calculated differently:
\[ \frac{u_Q}{Q} = \sqrt{ \left(\frac{u_A}{A}\right)^2+ \left(\frac{u_B}{B}\right)^2 } \]
Here, \(u_A\), \(u_B\), and \(u_Q\) represent standard uncertainties.
Substituting:
\[ \begin{aligned} \frac{u_Q}{Q} &=\sqrt{0.02^2+0.02^2}\\\ &=0.0283 \end{aligned} \]
The combined relative standard uncertainty is approximately 2.83%, rather than 4%.
These answers are not contradictory. They describe different uncertainty conventions.
- Adding percentages gives the maximum-bound estimate.
- Combining independent standard uncertainties in quadrature gives the standard uncertainty of the product.
Do not switch between these methods halfway through a calculation. Use the convention specified in the question.
There is another important detail. If you calculate \(Q=A^2\), the two appearances of \(A\) represent the same measurement, not two independent measurements. You must not treat them as independent when using statistical propagation.
Uncertainty is not the same as error
An uncertainty describes the estimated range or statistical spread associated with a measurement.
An error is the difference between a measured value and its true or accepted value.
For example, a student might measure a length as:
\[ L=20.0\pm0.2\text{ cm} \]
If the accepted length is \(20.1\text{ cm}\), the absolute error is \(0.1\text{ cm}\).
The uncertainty is still \(0.2\text{ cm}\).
They answer different questions:
- Uncertainty: How precisely was the measurement determined?
- Error: How far did the measurement differ from the reference value?
What about standard deviation?
Standard deviation describes how spread out repeated measurements are around their mean.
It can help estimate standard uncertainty when an appropriate statistical method is specified. However, it is not automatically the maximum uncertainty or the uncertainty in the mean.
A set of repeated measurements can have a small standard deviation while still containing a systematic error.
For a more detailed explanation, see Percentage Error vs Percentage Uncertainty: HSC Physics Guide.
03Questions and solutions
The following questions progress from straightforward multiplication to situations where you need to combine several sources of uncertainty or question the assumptions behind the usual formula.
For Questions 1-4, treat the stated uncertainties as maximum bounds. Assume the measured quantities can vary independently within their stated intervals unless otherwise specified.
Question 1
A student measures a rectangular metal sheet.
The length is \(12.0\pm0.1\text{ cm}\), and the width is \(5.0\pm0.1\text{ cm}\).
Calculate:
(a) The area of the sheet.
(b) The maximum percentage uncertainty in the area.
(c) The maximum absolute uncertainty in the area.
Solution 1
The area is:
\[ \boxed{A=(60.0\pm1.7)\text{ cm}^2} \]
The maximum percentage uncertainty is approximately 2.83%.
(a) Calculate the area.
Use:
\[ A=LW \]
Substitute:
\[ \begin{aligned} A&=12.0\times5.0\\\ &=60.0\text{ cm}^2 \end{aligned} \]
(b) Calculate the percentage uncertainties.
For the length:
\[ \%\Delta L = \frac{0.1}{12.0}\times100 =0.833\% \]
For the width:
\[ \%\Delta W = \frac{0.1}{5.0}\times100 =2.0\% \]
Because area is calculated by multiplication, add the percentage uncertainties:
\[ \begin{aligned} \%\Delta A &=0.833\%+2.0\%\\\ &=2.833\% \end{aligned} \]
(c) Calculate the absolute uncertainty.
\[ \begin{aligned} \Delta A &=60.0\times\frac{2.833}{100}\\\ &=1.70\text{ cm}^2 \end{aligned} \]
Therefore:
\[ A=(60.0\pm1.7)\text{ cm}^2 \]
The width contributes more to the total uncertainty because its percentage uncertainty is larger, even though its absolute uncertainty is the same as the length’s.
Question 2
A student investigates the electrical power dissipated by a resistor.
A voltmeter connected in parallel with the resistor reads:
\[ V=9.00\pm0.15\text{ V} \]
An ammeter connected in series reads:
\[ I=0.420\pm0.010\text{ A} \]
The power dissipated is given by:
\[ P=VI \]
Calculate:
(a) The electrical power.
(b) The maximum percentage uncertainty in the power.
(c) The maximum absolute uncertainty in the power.
Solution 2
The power is:
\[ \boxed{P=(3.78\pm0.15)\text{ W}} \]
The maximum percentage uncertainty is approximately 4.05%.
(a) Calculate the power.
\[ P=VI \]
Substitute:
\[ \begin{aligned} P&=9.00\times0.420\\\ &=3.78\text{ W} \end{aligned} \]
(b) Calculate the percentage uncertainties.
For voltage:
\[ \begin{aligned} \%\Delta V &=\frac{0.15}{9.00}\times100\\\ &=1.67\% \end{aligned} \]
For current:
\[ \begin{aligned} \%\Delta I &=\frac{0.010}{0.420}\times100\\\ &=2.38\% \end{aligned} \]
Add the two percentages:
\[ \begin{aligned} \%\Delta P &=1.67\%+2.38\%\\\ &=4.05\% \end{aligned} \]
(c) Calculate the absolute uncertainty.
\[ \begin{aligned} \Delta P &=3.78\times\frac{4.05}{100}\\\ &=0.153\text{ W} \end{aligned} \]
Rounding to two significant figures gives \(0.15\text{ W}\).
Therefore:
\[ P=(3.78\pm0.15)\text{ W} \]
Notice that current contributes a larger percentage uncertainty than voltage. If the student wanted to improve the power measurement, improving the current measurement would have the greater effect.
Question 3
A straight wire of length \(0.120\pm0.002\text{ m}\) carries a current of \(2.00\pm0.04\text{ A}\) through a uniform magnetic field of \(0.250\pm0.005\text{ T}\).
The wire is perpendicular to the magnetic field, so the magnetic force is:
\[ F=BIL \]
Calculate:
(a) The magnetic force on the wire.
(b) The maximum percentage uncertainty in the force.
(c) The maximum absolute uncertainty in the force.
(d) Explain why the percentage uncertainties of all three measured quantities must be included.
Solution 3
The magnetic force is:
\[ \boxed{F=(0.0600\pm0.0034)\text{ N}} \]
The maximum percentage uncertainty is approximately 5.67%.
(a) Calculate the force.
Use:
\[ F=BIL \]
Substitute:
\[ \begin{aligned} F&=0.250\times2.00\times0.120\\\ &=0.0600\text{ N} \end{aligned} \]
(b) Calculate each percentage uncertainty.
Magnetic field:
\[ \%\Delta B = \frac{0.005}{0.250}\times100 =2.0\% \]
Current:
\[ \%\Delta I = \frac{0.04}{2.00}\times100 =2.0\% \]
Wire length:
\[ \%\Delta L = \frac{0.002}{0.120}\times100 =1.67\% \]
(c) Calculate the combined uncertainty.
All three measured quantities are multiplied, so add all three percentage uncertainties:
\[ \begin{aligned} \%\Delta F &=2.0\%+2.0\%+1.67\%\\\ &=5.67\% \end{aligned} \]
Convert this into an absolute uncertainty:
\[ \begin{aligned} \Delta F &=0.0600\times\frac{5.67}{100}\\\ &=0.00340\text{ N} \end{aligned} \]
Therefore:
\[ F=(0.0600\pm0.0034)\text{ N} \]
(d) Explain why all three uncertainties contribute.
The calculated force depends on the magnetic field strength, current, and length of wire inside the magnetic field.
A possible increase in any one of these measurements increases the calculated force, provided the other two quantities remain unchanged.
Because all three quantities are multiplied, each contributes to the possible relative change in the final result.
Leaving out one percentage uncertainty would underestimate the maximum uncertainty in the force.
Question 4
A student wants to calculate the density of a solid cylindrical metal sample.
The following measurements are obtained:
| Measurement | Result |
|---|---|
| Mass | \(0.540\pm0.003\text{ kg}\) |
| Diameter | \(4.00\pm0.04\text{ cm}\) |
| Height | \(10.0\pm0.1\text{ cm}\) |
The cylinder’s volume is:
\[ V=\frac{\pi d^2h}{4} \]
Its density is:
\[ \rho=\frac{m}{V} \]
Calculate:
(a) The volume of the cylinder.
(b) The density of the metal in \(\mathrm{kg\\,m^{-3}}\).
(c) The maximum percentage uncertainty in the density.
(d) The maximum absolute uncertainty in the density.
(e) Explain why the percentage uncertainty in the diameter is counted twice.
Solution 4
The density is approximately:
\[ \boxed{ \rho=(4.30\pm0.15)\times10^3 \text{ kg m}^{-3} } \]
The maximum percentage uncertainty is approximately 3.56%.
(a) Calculate the volume.
Use:
\[ V=\frac{\pi d^2h}{4} \]
Substitute:
\[ \begin{aligned} V&=\frac{\pi(4.00)^2(10.0)}{4}\\\ &=40\pi\\\ &=125.66\text{ cm}^3 \end{aligned} \]
Convert to cubic metres:
\[ V=1.2566\times10^{-4}\text{ m}^3 \]
(b) Calculate the density.
Use:
\[ \rho=\frac{m}{V} \]
Substitute:
\[ \begin{aligned} \rho &=\frac{0.540}{1.2566\times10^{-4}}\\\ &=4297.2\text{ kg m}^{-3} \end{aligned} \]
To three significant figures:
\[ \rho=4.30\times10^3\text{ kg m}^{-3} \]
(c) Calculate the maximum percentage uncertainty.
First, calculate the percentage uncertainty in mass:
\[ \begin{aligned} \%\Delta m &=\frac{0.003}{0.540}\times100\\\ &=0.556\% \end{aligned} \]
Next, calculate the percentage uncertainty in diameter:
\[ \begin{aligned} \%\Delta d &=\frac{0.04}{4.00}\times100\\\ &=1.0\% \end{aligned} \]
The diameter is squared in the volume equation, so its contribution is:
\[ 2\times1.0\%=2.0\% \]
Finally, calculate the percentage uncertainty in height:
\[ \begin{aligned} \%\Delta h &=\frac{0.1}{10.0}\times100\\\ &=1.0\% \end{aligned} \]
The density equation can be written as:
\[ \rho=\frac{4m}{\pi d^2h} \]
The maximum percentage uncertainty is therefore:
\[ \begin{aligned} \%\Delta\rho &=\%\Delta m+2(\%\Delta d)+\%\Delta h\\\ &=0.556\%+2.0\%+1.0\%\\\ &=3.556\% \end{aligned} \]
Notice that the factor \(4/\pi\) contributes no uncertainty because it is an exact mathematical constant.
(d) Calculate the absolute uncertainty.
\[ \begin{aligned} \Delta\rho &=4297.2\times\frac{3.556}{100}\\\ &=152.8\text{ kg m}^{-3} \end{aligned} \]
Rounding appropriately:
\[ \Delta\rho=0.15\times10^3\text{ kg m}^{-3} \]
Therefore:
\[ \rho=(4.30\pm0.15)\times10^3 \text{ kg m}^{-3} \]
(e) Explain why the diameter uncertainty is counted twice.
The diameter appears as \(d^2\) in the volume equation.
A change in diameter therefore affects the volume through two multiplied factors of \(d\).
For small uncertainties, a 1% increase in diameter produces approximately a 2% increase in the volume.
Because density is inversely proportional to volume, the diameter contributes twice its percentage uncertainty to the density calculation as well.
This is a common exam trap: using the percentage uncertainty in diameter only once would underestimate the uncertainty in the final density.
Question 5
A student measures the work done when a horizontal force moves a trolley along a straight track.
The measured force and displacement are:
\[ F=(10.0\pm4.0)\text{ N} \]
\[ s=(2.00\pm0.50)\text{ m} \]
Both uncertainties are maximum bounds. Assume the force and displacement can vary independently anywhere within their stated intervals, and the force remains parallel to the displacement.
The student calculates:
\[ W=Fs \]
They then add the percentage uncertainties and report:
\[ W=(20.0\pm13.0)\text{ J} \]
Answer the following:
(a) Verify the student’s central value and percentage uncertainty using the usual HSC multiplication method.
(b) Calculate the exact minimum and maximum possible work using the measurement intervals.
(c) Explain why the student’s symmetric uncertainty interval does not exactly represent the possible range of work.
(d) The student can improve either measurement, but can only halve one absolute uncertainty. Should they halve the force uncertainty or the displacement uncertainty to produce the greater reduction in the exact range of possible work? Show the calculations supporting your decision.
Solution 5
The student’s central value and approximate 65% uncertainty are correct under the usual first-order HSC method. However, the exact possible work interval is:
\[ \boxed{9.0\leq W\leq35.0\text{ J}} \]
The difference arises because the percentage method neglects a small second-order term. In this example, the uncertainties are large enough for that term to matter.
(a) Verify the usual percentage uncertainty calculation.
The central work is:
\[ \begin{aligned} W&=Fs\\\ &=10.0\times2.00\\\ &=20.0\text{ J} \end{aligned} \]
The percentage uncertainty in force is:
\[ \%\Delta F = \frac{4.0}{10.0}\times100 =40\% \]
The percentage uncertainty in displacement is:
\[ \%\Delta s = \frac{0.50}{2.00}\times100 =25\% \]
Adding them:
\[ \begin{aligned} \%\Delta W &=40\%+25\%\\\ &=65\% \end{aligned} \]
The approximate absolute uncertainty is:
\[ \begin{aligned} \Delta W &=20.0\times\frac{65}{100}\\\ &=13.0\text{ J} \end{aligned} \]
Therefore, the usual HSC approximation gives:
\[ W=(20.0\pm13.0)\text{ J} \]
The corresponding symmetric interval is:
\[ 7.0\leq W\leq33.0\text{ J} \]
(b) Calculate the exact minimum and maximum work.
The force interval is:
\[ 6.0\leq F\leq14.0\text{ N} \]
The displacement interval is:
\[ 1.50\leq s\leq2.50\text{ m} \]
Both quantities are positive, so the minimum work occurs when both are at their minimum values:
\[ \begin{aligned} W_{\min} &=F_{\min}s_{\min}\\\ &=6.0\times1.50\\\ &=9.0\text{ J} \end{aligned} \]
Similarly, the maximum work occurs when both are at their maximum values:
\[ \begin{aligned} W_{\max} &=F_{\max}s_{\max}\\\ &=14.0\times2.50\\\ &=35.0\text{ J} \end{aligned} \]
The exact interval is:
\[ \boxed{9.0\leq W\leq35.0\text{ J}} \]
(c) Explain why the intervals differ.
The usual percentage uncertainty method assumes that the relative changes are small enough for higher-order terms to be ignored.
To see what happens, write the upper limits as:
\[ F_{\max}=F+\Delta F \]
\[ s_{\max}=s+\Delta s \]
Their product is:
\[ \begin{aligned} W_{\max} &=(F+\Delta F)(s+\Delta s)\\\ &=Fs+F\Delta s+s\Delta F\\\ &\quad+\Delta F\Delta s \end{aligned} \]
The usual percentage method includes the first three terms but ignores the final term:
\[ \Delta F\Delta s \]
This term represents the extra increase when both quantities are simultaneously above their central values.
Here, that extra contribution is:
\[ 4.0\times0.50=2.0\text{ J} \]
The approximate upper limit is therefore \(33.0\text{ J}\), while the exact upper limit is \(35.0\text{ J}\).
The same issue occurs at the lower end, where the exact interval is shifted relative to the symmetric estimate.
This reveals an important limitation: adding percentage uncertainties is a first-order approximation, not an exact interval calculation for arbitrarily large uncertainties.
For the small uncertainties usually encountered in HSC problems, the approximation is generally appropriate. When uncertainties are large, calculate the endpoint products directly if the question asks for the exact possible interval.
(d) Decide which measurement should be improved.
We compare the effect of halving each absolute uncertainty separately.
Option 1: Halve the force uncertainty.
The improved force measurement becomes:
\[ F=(10.0\pm2.0)\text{ N} \]
Its interval is:
\[ 8.0\leq F\leq12.0\text{ N} \]
The displacement remains:
\[ 1.50\leq s\leq2.50\text{ m} \]
The minimum work becomes:
\[ W_{\min}=8.0\times1.50=12.0\text{ J} \]
The maximum work becomes:
\[ W_{\max}=12.0\times2.50=30.0\text{ J} \]
The new interval is:
\[ 12.0\leq W\leq30.0\text{ J} \]
Its width is:
\[ 30.0-12.0=18.0\text{ J} \]
Option 2: Halve the displacement uncertainty.
The improved displacement measurement becomes:
\[ s=(2.00\pm0.25)\text{ m} \]
Its interval is:
\[ 1.75\leq s\leq2.25\text{ m} \]
The force remains:
\[ 6.0\leq F\leq14.0\text{ N} \]
The minimum work becomes:
\[ W_{\min}=6.0\times1.75=10.5\text{ J} \]
The maximum work becomes:
\[ W_{\max}=14.0\times2.25=31.5\text{ J} \]
The new interval is:
\[ 10.5\leq W\leq31.5\text{ J} \]
Its width is:
\[ 31.5-10.5=21.0\text{ J} \]
Conclusion: Halving the force uncertainty produces the greater reduction in the possible range of work.
The force improvement reduces the interval width from \(26.0\text{ J}\) to \(18.0\text{ J}\), whereas the displacement improvement reduces it to \(21.0\text{ J}\).
The tempting approach is to compare the absolute uncertainties of \(4.0\text{ N}\) and \(0.50\text{ m}\). But those values have different units, so comparing their numerical sizes tells you nothing useful.
Instead, compare their relative contributions to the product. Force initially contributes 40%, while displacement contributes 25%.
This question also shows why uncertainty propagation is more than a mechanical formula. You need to understand what the measurements represent and how their possible values interact.
04Where to go next
Once you’ve calculated the uncertainty in a derived quantity, the next step is often to compare it with an accepted value or another experimental result.
That requires understanding measurement intervals and error bars. In particular, overlapping uncertainty intervals can indicate compatibility, but they do not prove that two results are identical.
Continue with Do Overlapping Error Bars Mean Two Results Agree? to learn how to make that comparison correctly.