HSC Chemistry Module 8: Choosing the Right Analysis Method

Learn how to choose between qualitative and quantitative analysis methods in HSC Chemistry Module 8. Explore ion identification, gravimetric analysis, titrations, spectroscopy, organic structure identification, and how to evaluate the reliability of results.

A clear solution can contain chloride ions, dissolved copper, or a dangerous concentration of a metal without giving you any visible clue. A test might tell you which substance is present, but that doesn’t automatically tell you how much is there. Choose the wrong analytical method, and you can end up with a precise answer to the wrong question.

HSC Chemistry Module 8: Applying Chemical Ideas requires you to understand how chemists identify substances, determine their composition, and measure concentrations. This checklist focuses on choosing between qualitative and quantitative analysis, understanding the main analytical techniques, and deciding whether the evidence actually supports your conclusion. It is a map of the topic, not a replacement for the detailed calculations you practise in titrations, spectroscopy, and other areas of the course.

01Start with the question you need to answer

Module 8 has two main analysis strands: identifying ions in aqueous solutions, and identifying the functional groups and structures of organic compounds. The separate inquiry into chemical synthesis and design is outside this checklist.

The current NSW Chemistry Stage 6 Syllabus (2017) remains the Year 12 syllabus before the replacement course is implemented in 2028. See the official NSW syllabus information.

Before choosing a technique, decide what the evidence needs to establish.

Your questionType of analysisWhat you need
Is chloride present?QualitativeAn observation that supports its presence
How much chloride is present?QuantitativeA concentration or amount
Which functional group is present?QualitativeA characteristic chemical reaction or spectral feature
Which organic structure fits the evidence?Structural analysisSeveral consistent pieces of evidence
Can we trust the reported concentration?EvaluationCalibration, controls, repeatability, and an assessment of error
Decision flowchart for choosing HSC Chemistry analytical methods based on whether the goal is ion identification, ion concentration, organic structure identification, or evaluation of result reliability.
Choose the analytical method according to the question being investigated. Qualitative tests identify species, quantitative methods measure amounts or concentrations, combined spectroscopic evidence helps identify organic structures, and calibration, blanks, repeat measurements, and uncertainty help evaluate reliability.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The important distinction is that a method can be excellent at one task and unsuitable for another. A flame test may help identify a metal ion, but it cannot reliably measure its concentration. AAS can measure the concentration of a metal element, but it does not identify the complete molecular structure of a compound containing that metal.

Your method must match the question.

02Qualitative analysis: identify ions without jumping to conclusions

Imagine testing a colourless water sample. You add a reagent, and a white solid appears. You have evidence of a chemical reaction, but have you identified the ion?

Not yet. Several different ions form white precipitates. The next step is to choose a test that distinguishes between the possible explanations.

Flame tests and precipitation reactions

A flame test works because heating excites electrons in certain atoms or ions. As the electrons return to lower energy levels, they emit light at characteristic wavelengths.

Schematic of electron excitation and photon emission alongside three characteristic flame-test colours: green for barium, orange-red for calcium, and blue-green for copper.
Heating excites electrons in atoms or ions to higher energy levels. When electrons return to lower energy levels, they emit photons whose energies correspond to the differences between those levels. The emitted wavelengths produce characteristic flame colours that can help identify metal ions. The colours shown are representative; contamination and experimental conditions can affect observations.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Flame tests are useful for distinguishing some metal ions, particularly \\(\ce{Ba^{2+}}\\), \\(\ce{Ca^{2+}}\\), and \\(\ce{Cu^{2+}}\\). However, contamination and overlapping colours can make identification difficult, especially in mixtures.

Precipitation reactions provide another approach. A precipitate is an insoluble solid formed when dissolved species react.

The following table summarises common tests for the HSC course. These are useful starting points, not a collection of tests that can be applied indiscriminately to every mixture.

CationUseful testCharacteristic observation
\\(\ce{Ba^{2+}}\\)Add a soluble sulfateWhite \\(\ce{BaSO4}\\) precipitate
\\(\ce{Ca^{2+}}\\)Flame testOrange-red flame
\\(\ce{Mg^{2+}}\\)Add \\(\ce{NaOH}\\)White \\(\ce{Mg(OH)2}\\) precipitate
\\(\ce{Pb^{2+}}\\)Add iodide ionsYellow \\(\ce{PbI2}\\) precipitate
\\(\ce{Ag+}\\)Add chloride ionsWhite \\(\ce{AgCl}\\) precipitate
\\(\ce{Cu^{2+}}\\)Add \\(\ce{NaOH}\\)Blue \\(\ce{Cu(OH)2}\\) precipitate
\\(\ce{Fe^{2+}}\\)Add \\(\ce{NaOH}\\)Green precipitate, which may turn brown in air
\\(\ce{Fe^{3+}}\\)Add \\(\ce{NaOH}\\)Red-brown \\(\ce{Fe(OH)3}\\) precipitate

Complexation reactions provide additional evidence. For example, adding excess ammonia to a suitable copper(II) solution produces a characteristic deep-blue complex. This can help distinguish copper(II) from ions that form different complexes or precipitates.

Comparison of four characteristic precipitation reactions: blue copper(II) hydroxide, green iron(II) hydroxide, red-brown iron(III) hydroxide, and yellow lead(II) iodide.
Schematic comparison of the characteristic precipitate colours used in qualitative analysis. Sodium hydroxide produces blue Cu(OH)₂, green Fe(OH)₂, and red-brown Fe(OH)₃ precipitates; iodide ions produce yellow PbI₂. Fresh iron(II) hydroxide can turn brown as it oxidises in air. Colours are representative observations, not proof of identity on their own.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Tests for anions

AnionUseful testCharacteristic observation
\\(\ce{Cl-}\\)Acidify with dilute nitric acid, then add \\(\ce{AgNO3}\\)White \\(\ce{AgCl}\\) precipitate
\\(\ce{Br-}\\)Acidified silver nitrateCream \\(\ce{AgBr}\\) precipitate
\\(\ce{I-}\\)Acidified silver nitrateYellow \\(\ce{AgI}\\) precipitate
\\(\ce{CO3^{2-}}\\)Add dilute acidEffervescence as \\(\ce{CO2}\\) forms
\\(\ce{SO4^{2-}}\\)Add a suitable soluble barium salt under acidic conditionsWhite \\(\ce{BaSO4}\\) precipitate
\\(\ce{OH-}\\)Use a pH indicatorAlkaline pH
\\(\ce{PO4^{3-}}\\)Use an appropriate phosphate test, such as acidified ammonium molybdateYellow precipitate under suitable conditions
\\(\ce{CH3COO-}\\)Acidify a suitable sampleEthanoic acid may be released; use any odour test only under supervised laboratory procedures

Two details are especially important.

First, acidify the sample with dilute nitric acid before the silver nitrate test for halides. Do not use hydrochloric acid: it introduces chloride ions and can create the very positive result you are trying to investigate.

Second, carbonate and sulfate can both produce white precipitates with barium ions. Their behaviour in acid distinguishes them. Barium carbonate dissolves in dilute acid with carbon dioxide released, whereas barium sulfate remains insoluble in dilute acid.

The relevant ionic equations are:

\\[ \ce{Ba^{2+} + SO4^{2-} -> BaSO4(s)} \\]

\\[ \ce{CO3^{2-} + 2H+ -> CO2(g) + H2O(l)} \\]

The first equation shows precipitation. The second explains the bubbles observed during the carbonate test.

Common trap: a negative test does not always prove an ion is absent. Its concentration may be too low for a visible observation, or another species may interfere. Use appropriate confirmatory tests, preferably on fresh aliquots of the original sample.

03Quantitative analysis: measure how much is present

Once you know which species you are investigating, the next decision is how to measure its amount.

Three important ideas underpin quantitative analysis:

  • Convert a measured mass into moles using \\(n=m/M\\).
  • Convert a measured volume and concentration into moles using \\(n=cV\\), with volume in litres.
  • Use a calibrated instrument when the concentration is inferred from a signal such as light absorption.

Here, \\(n\\) is amount in moles, \\(m\\) is mass in grams, \\(M\\) is molar mass in grams per mole, \\(c\\) is concentration in moles per litre, and \\(V\\) is volume in litres.

Choosing a quantitative method

MethodWhat it measuresBest suited to
Gravimetric analysisMass of a precipitateDetermining an ion’s amount from a known reaction stoichiometry
Precipitation titrationVolume of a standard solution required for reactionDetermining concentrations of ions such as chloride
ColourimetryAbsorbance of visible lightMeasuring coloured species or coloured complexes
UV-visible spectrophotometryAbsorbance across ultraviolet and visible wavelengthsQuantifying suitable absorbing species
Atomic absorption spectroscopy (AAS)Absorption of characteristic light by free atomsMeasuring metal concentrations, often at low levels

Gravimetric analysis: let the precipitate reveal the amount

In gravimetric analysis, a known amount of sample is reacted to form a precipitate containing the analyte, the species being measured. The solid is separated, washed, dried, and weighed.

Four-stage gravimetric analysis process showing precipitate formation in a beaker, filtration and washing through filter paper, drying the collected solid, and weighing the dry precipitate on a balance.
Gravimetric analysis determines an analyte’s amount from the measured mass of a precipitate with known chemical composition. The solid is separated and washed to remove soluble impurities, then dried to constant mass before weighing. The balanced reaction equation connects the precipitate mass to the amount of analyte.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The calculation depends on the balanced chemical equation and the mole ratio between the precipitate and the analyte.

Worked example: determine sulfate by gravimetric analysis

A \\(0.500\text{ g}\\) fertiliser sample produces \\(0.233\text{ g}\\) of dry, pure \\(\ce{BaSO4}\\). Calculate the percentage by mass of sulfate ions in the sample.

Given \\(M(\ce{BaSO4})=233.4\text{ g mol}^{-1}\\) and \\(M(\ce{SO4^{2-}})=96.06\text{ g mol}^{-1}\\).

First, calculate the amount of barium sulfate:

\\[ n(\ce{BaSO4})=\frac{0.233}{233.4} =9.98\times10^{-4}\text{ mol} \\]

Each mole of \\(\ce{BaSO4}\\) contains one mole of sulfate, so the sulfate amount is also \\(9.98\times10^{-4}\text{ mol}\\).

\\[ \begin{aligned} m(\ce{SO4^{2-}})&=nM\\ &=(9.98\times10^{-4})(96.06)\\ &=0.0959\text{ g} \end{aligned} \\]

Therefore,

\\[ \begin{aligned} \%\ce{SO4^{2-}} &=\frac{0.0959}{0.500}\times100\\ &=\boxed{19.2\%} \end{aligned} \\]

The sample contains \\(19.2\%\\) sulfate by mass, assuming precipitation was complete and the collected solid was pure and dry.

A wet precipitate would give a mass that is too high. Losing solid during filtration or transfer would give a mass that is too low.

Precipitation titration: use volume to calculate concentration

A precipitation titration determines an unknown concentration by reacting the analyte with a standard solution until the reaction reaches its endpoint.

For chloride, silver ions form insoluble silver chloride:

\\[ \ce{Ag+ + Cl- -> AgCl(s)} \\]

The mole ratio is \\(1:1\\). At the equivalence point, the reacting amounts of silver ions and chloride ions are equal.

In the Mohr method, potassium chromate is used as an indicator. Once the chloride has been precipitated, excess silver ions produce a reddish-brown silver chromate precipitate. The method requires suitable pH conditions, and the endpoint is an experimental indication of the equivalence point.

Schematic of a Mohr precipitation titration, with a silver nitrate burette above a conical flask containing chloride solution and potassium chromate indicator. White silver chloride precipitate forms, followed by a small reddish-brown endpoint precipitate of silver chromate.
In the Mohr method, silver ions first precipitate chloride ions as white AgCl. Once the chloride has been consumed, a slight excess of silver ions reacts with chromate indicator to form reddish-brown Ag₂CrO₄, signalling the endpoint. The titration requires suitable pH conditions. The endpoint approximates the equivalence point.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Worked example: calculate chloride concentration in water

A qualitative test suggests that a water sample contains chloride ions. A \\(25.00\text{ mL}\\) sample is titrated with \\(0.0100\text{ mol L}^{-1}\\) silver nitrate. The mean titre is \\(18.60\text{ mL}\\). Calculate the chloride concentration in \\(\text{mol L}^{-1}\\) and \\(\text{mg L}^{-1}\\).

Step 1: Calculate the moles of silver ions added.

Convert the titre to litres:

\\[ V=18.60\times10^{-3}\text{ L} \\]

Then use \\(n=cV\\):

\\[ n(\ce{Ag+})=0.0100\times0.01860 =1.860\times10^{-4}\text{ mol} \\]

Step 2: Use the reaction ratio.

Because \\(\ce{Ag+}\\) and \\(\ce{Cl-}\\) react in a \\(1:1\\) ratio,

\\[ n(\ce{Cl-})=1.860\times10^{-4}\text{ mol} \\]

Step 3: Calculate the chloride concentration.

The original sample volume is \\(0.02500\text{ L}\\).

\\[ \begin{aligned} c(\ce{Cl-})&=\frac{n}{V}\\ &=\frac{1.860\times10^{-4}}{0.02500}\\ &=0.007440\text{ mol L}^{-1} \end{aligned} \\]

Step 4: Convert to milligrams per litre.

Using \\(M(\ce{Cl-})=35.45\text{ g mol}^{-1}\\),

\\[ \begin{aligned} c&=0.007440\times35.45\\ &=0.2639\text{ g L}^{-1}\\ &=\boxed{264\text{ mg L}^{-1}} \end{aligned} \\]

The sample contains approximately \\(264\text{ mg}\\) of chloride ions per litre. The qualitative test helped identify the species; the titration measured its concentration.

Colourimetry, UV-visible spectrophotometry, and AAS

Colourimetry and UV-visible spectrophotometry measure how much light a sample absorbs. The analyte may already be coloured, or it may react to form a coloured complex.

Within a suitable concentration range, absorbance increases with concentration. A calibration curve, made using standards of known concentration, allows an unknown concentration to be estimated from its absorbance.

Spectrophotometry teaching diagram showing the light path from source through wavelength selector and sample cuvette to detector, alongside a calibration graph of absorbance against concentration with standards and an unknown reading.
The instrument light path is light source → wavelength selector → sample cuvette → detector. The calibration data are illustrative: absorbance increases linearly with concentration over the shown range. An unknown absorbance of 0.30 intersects the calibration line at 5.0 mg L⁻¹. This estimate is valid only if the unknown is measured under the same conditions and lies within the calibrated range.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

AAS uses a different process. The sample is atomised, and free atoms of the target metal absorb light at characteristic wavelengths. The absorption is used to determine the metal concentration.

The key limitation is that the instrument’s reading depends on the species the method actually measures. AAS measures the amount of an element recovered by the procedure; it does not, by itself, identify the element’s original chemical form or oxidation state.

For colourimetry and UV-visible spectrophotometry, use a suitable blank, consistent conditions, and a calibration curve that covers the unknown’s concentration. Do not assume a calibration remains linear indefinitely.

04Organic analysis: identify functional groups, then build the structure

Organic analysis follows the same logic as ion analysis: begin with evidence, then narrow down the possible structures.

Qualitative tests for functional groups

Feature being testedTestPositive observation
Carbon-carbon double bond, \\(\ce{C=C}\\)Add bromine waterOrange-brown colour disappears
Alcohol hydroxyl group, \\(\ce{-OH}\\)Oxidise with acidified dichromate under suitable conditionsOrange solution turns green for oxidisable primary or secondary alcohols
Carboxylic acid, \\(\ce{-COOH}\\)Add sodium carbonateEffervescence as \\(\ce{CO2}\\) forms

These tests narrow the possibilities, but they do not identify the entire molecule. For example, a positive test for a hydroxyl group does not distinguish every alcohol isomer.

What each spectrum tells you

Four-panel comparison of simplified analytical spectra: IR with a broad O–H absorption, mass spectrometry with molecular-ion and fragment peaks, carbon-13 NMR with distinct carbon signals, and proton NMR with integrated hydrogen signals.
These schematic spectra provide complementary evidence for identifying an organic structure. IR helps identify functional groups, mass spectrometry provides molecular-mass and fragmentation evidence, carbon-13 NMR reveals distinct carbon environments, and proton NMR reveals hydrogen environments and relative hydrogen counts through integration. The patterns are illustrative, not experimental data.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

TechniqueMain informationCommon trap
Infrared spectroscopy (IR)Types of bonds and functional groupsOne absorption rarely establishes a complete structure
Mass spectrometry (MS)Molecular mass when a molecular ion is observed, plus fragment informationThe base peak is not necessarily the molecular ion
Carbon-13 NMRNumber of distinct carbon environmentsThe number of signals is not always the total number of carbon atoms
Proton NMRDistinct hydrogen environments, relative numbers of hydrogens, and splitting patternsSignals and integration must be interpreted together

Consider propan-1-ol and propan-2-ol. Both have the molecular formula \\(\ce{C3H8O}\\), so both have the same molecular mass. Both contain an alcohol group and can show a broad O-H absorption in an IR spectrum.

However, propan-1-ol has three distinct carbon environments, whereas propan-2-ol has two. Their NMR evidence can therefore distinguish the isomers even when the molecular mass and functional-group test cannot.

The strongest structural conclusion comes from combining evidence. A molecular formula constrains the possibilities, chemical tests identify functional groups, and spectra help distinguish between the remaining structures.

05Before accepting a result, check the evidence

A result is only useful if the method measures the quantity you actually care about and the measurement is reliable enough for the decision being made.

Use this checklist when evaluating an investigation or an exam response:

  • Define the analyte. Are you measuring chloride concentration, dissolved copper, or total recoverable copper? These are not interchangeable.
  • Check sample preparation. Filtration, dilution, digestion, and reagent choice can change what is measured.
  • Check calibration and controls. Standards establish the relationship between a signal and concentration. Blanks can reveal contamination or background signals.
  • Consider precision and accuracy. Repeatable readings can still be systematically wrong. Agreement between repeats does not prove the method is accurate.
  • Identify possible interference. Other ions, sample colour, suspended solids, and incomplete reactions may affect the result.
  • Match the conclusion to the evidence. A test may support the presence of an ion without proving that it is the only ion present.

When a question asks you to evaluate a method, don’t simply call it “accurate” or “reliable”. Explain which limitation matters, how it could affect the result, and what change would improve the investigation.

06Questions and solutions

Question 1

An aqueous sample is acidified with dilute nitric acid and then treated with silver nitrate. A white precipitate forms.

Identify the most likely anion and write the ionic equation for the reaction. Explain why nitric acid is used instead of hydrochloric acid.

Solution 1

The most likely anion is chloride, \\(\ce{Cl-}\\), which forms white silver chloride.

The ionic equation is:

\\[ \ce{Ag+ + Cl- -> AgCl(s)} \\]

Nitric acid does not introduce chloride ions. Hydrochloric acid does, so using it could produce a false positive by adding the ion being tested for.

The white precipitate supports the presence of chloride, but a complete analysis must still consider possible interference and whether additional confirmatory evidence is needed.

Question 2

A student investigates an unknown solution using two separate aliquots.

  • In the first aliquot, adding barium nitrate produces a white precipitate. Adding dilute nitric acid to that precipitate causes it to dissolve with effervescence.
  • In the second aliquot, acidification with dilute nitric acid followed by silver nitrate produces a white precipitate.

Identify the two anions supported by the observations. Explain why the first test does not support sulfate as the explanation for the white precipitate, and write the relevant ionic equations.

Solution 2

The observations support the presence of carbonate ions, \\(\ce{CO3^{2-}}\\), and chloride ions, \\(\ce{Cl-}\\).

In the first aliquot, barium ions form white barium carbonate:

\\[ \ce{Ba^{2+} + CO3^{2-} -> BaCO3(s)} \\]

The carbonate precipitate reacts with acid, releasing carbon dioxide gas:

\\[ \ce{CO3^{2-} + 2H+ -> CO2(g) + H2O(l)} \\]

The dissolution with effervescence supports carbonate. Barium sulfate would also be white, but it would remain insoluble in dilute nitric acid. The acid behaviour therefore distinguishes the two possible explanations.

In the second aliquot, the white precipitate is consistent with silver chloride:

\\[ \ce{Ag+ + Cl- -> AgCl(s)} \\]

The important reasoning is that colour alone is insufficient. The follow-up reaction provides the evidence needed to distinguish carbonate from sulfate.

Question 3

An unknown organic compound has the molecular formula \\(\ce{C3H8O}\\). Its mass spectrum shows a molecular ion at \\(m/z=60\\). Its IR spectrum contains a broad O-H absorption, and acidified dichromate changes from orange to green when reacted with the compound.

The carbon-13 NMR spectrum contains two signals. The proton NMR integrations have a ratio of \\(6:1:1\\).

Identify the compound and explain how the evidence supports your answer. Why would the molecular mass alone be insufficient?

Solution 3

The compound is propan-2-ol, \\(\ce{CH3CH(OH)CH3}\\).

The molecular ion at \\(m/z=60\\) is consistent with a molecular mass of \\(60\\), as expected for \\(\ce{C3H8O}\\). However, other isomers can have the same formula and molecular mass, so this evidence does not uniquely identify the structure.

The broad O-H absorption supports an alcohol functional group. The orange-to-green dichromate change supports an oxidisable alcohol, consistent with a secondary alcohol.

The two carbon-13 NMR signals show that the molecule contains two distinct carbon environments. In propan-2-ol, the two methyl groups are equivalent, while the central carbon has a different environment.

The proton NMR integration ratio \\(6:1:1\\) is also consistent with six equivalent methyl hydrogens, one hydrogen on the central carbon, and one hydroxyl hydrogen. Together, these results support propan-2-ol rather than propan-1-ol or an ether isomer.

Question 4

A student prepares a calibration curve for a coloured complex. The standards give the following results.

Concentration (mg L\\(^{-1}\\))Absorbance
00.00
20.12
40.24
60.36

The unknown sample has an absorbance of \\(0.72\\). A \\(10.0\text{ mL}\\) aliquot is diluted to a final volume of \\(25.0\text{ mL}\\), giving an absorbance of \\(0.288\\).

Calculate the original concentration. Explain why the diluted result is more defensible than directly using the original absorbance.

Solution 4

The original concentration is \\(12.0\text{ mg L}^{-1}\\), based on the diluted sample’s absorbance and the calibration curve.

First, determine the relationship between concentration and absorbance. The standards show a slope of

\\[ \frac{0.12}{2}=0.060 \\]

absorbance units per \\(\text{mg L}^{-1}\\).

The diluted sample concentration is therefore

\\[ c_{\text{diluted}}=\frac{0.288}{0.060} =4.80\text{ mg L}^{-1} \\]

The dilution factor is

\\[ \frac{25.0}{10.0}=2.50 \\]

So the original concentration is

\\[ \begin{aligned} c_{\text{original}} &=4.80\times2.50\\ &=\boxed{12.0\text{ mg L}^{-1}} \end{aligned} \\]

The original absorbance of \\(0.72\\) lies outside the range covered by the standards, which only extend to \\(0.36\\). Calculating directly from that reading requires extrapolating beyond the measured calibration range.

The diluted reading lies within the calibration range, so the result is better supported by the available data. This assumes the dilution was accurate and the diluted sample behaves consistently with the standards.

Question 5

An environmental laboratory must determine whether the total recoverable copper concentration in creek water exceeds a limit of \\(0.020\text{ mg L}^{-1}\\).

The sample contains suspended sediment. Two aliquots are analysed:

  • A filtered aliquot gives \\(0.018\text{ mg L}^{-1}\\) copper by AAS.
  • An unfiltered aliquot, after acid digestion, gives \\(0.026\text{ mg L}^{-1}\\) copper by AAS.

The field blank is below \\(0.001\text{ mg L}^{-1}\\). Two further unfiltered, digested aliquots give \\(0.025\\) and \\(0.027\text{ mg L}^{-1}\\). Assume the digestion procedure is validated for the required definition of total recoverable copper, and the aliquots are representative of the same well-mixed sample.

(a) Does the sample exceed the stated limit?

(b) Estimate the copper concentration associated with the suspended material.

(c) Explain why the filtered result cannot be used to answer the original question. Would the conclusion change if the limit applied to dissolved copper instead?

Solution 5

(a) Yes. The total recoverable copper concentration is approximately \\(0.026\text{ mg L}^{-1}\\), which exceeds the limit by \\(0.006\text{ mg L}^{-1}\\).

The unfiltered, digested result measures the copper recovered from the sample, including copper released from the suspended material by the validated digestion procedure.

The two additional measurements, \\(0.025\\) and \\(0.027\text{ mg L}^{-1}\\), agree closely with the original result. Their mean is also \\(0.026\text{ mg L}^{-1}\\). The low field blank provides evidence against substantial contamination, although it cannot rule out every possible systematic error.

(b) The estimated copper concentration associated with the suspended material is \\(0.008\text{ mg L}^{-1}\\).

Subtract the filtered result from the total recoverable result:

\\[ \begin{aligned} c_{\text{associated with solids}} &\approx 0.026-0.018\\ &=\boxed{0.008\text{ mg L}^{-1}} \end{aligned} \\]

This is an estimate based on the difference between the two measurements. It assumes that the aliquots are representative and that the methods have comparable recoveries for the dissolved copper.

(c) The filtered result answers a different question because filtration removes suspended material before analysis.

The filtered aliquot estimates dissolved copper under the stated procedure. It does not include the copper recovered from the suspended material during digestion.

If the limit instead applied to dissolved copper, the measured value of \\(0.018\text{ mg L}^{-1}\\) would be below the \\(0.020\text{ mg L}^{-1}\\) limit. However, the difference is small, and no measurement uncertainty has been supplied. A firm compliance conclusion would therefore require an assessment of uncertainty.

The tempting mistake is to choose the lower result because it appears reassuring. The correct choice depends on the quantity specified in the question: dissolved copper or total recoverable copper. A reliable instrument cannot compensate for measuring the wrong quantity.

The same principle applies throughout Module 8. Identify what the question requires, select a method that measures it, and combine the result with enough chemical evidence to justify your conclusion.