Switched Reluctance Motors: How Magnetic Torque Works

Learn how switched reluctance motors produce torque without rotor magnets by using changing magnetic reluctance and inductance. Explore phase switching, electromagnetic induction, worked examples, and challenging practice questions in this HSC Physics extension guide.

A motor can rotate even when its rotor contains no permanent magnets and no windings. In a switched reluctance motor, ordinary laminated steel rotor teeth are pulled towards the stator poles whose coils are energised. By switching the coils in the correct sequence, the motor produces continuous rotation.

The interesting question is how a changing magnetic circuit can produce torque without a permanent-magnet rotor. The answer involves a property called magnetic reluctance, and it introduces a different way of thinking about electromagnetic torque.

This is an extension topic beyond the required HSC Physics syllabus. Year 12 Electromagnetism provides the prerequisite knowledge, particularly the motor effect, magnetic flux, electromagnetic induction, and inductance. Understanding switched reluctance motors is additional learning, not an HSC assessment requirement.

01First, what happens in a conventional brushless DC motor?

Start with the motor model you already know.

When an electric current passes through a conductor in an external magnetic field, the conductor experiences a force. For a current-carrying wire perpendicular to a magnetic field:

\[ F=BIL \]

Here, \(B\) is magnetic field strength in tesla, \(I\) is current in amperes, and \(L\) is the length of wire within the field in metres.

In a simple DC motor, two sides of a current-carrying coil experience forces in opposite directions. Because these forces act on opposite sides of the rotation axis, they produce a turning effect called torque.

For a coil with \(N\) turns, the torque is:

\[ \tau=NIAB\sin\alpha \]

where:

  • \(\tau\) is torque in newton metres (Nm).
  • \(N\) is the number of turns in the coil.
  • \(I\) is the current in amperes.
  • \(A\) is the area of the coil in square metres.
  • \(B\) is the magnetic field strength in tesla.
  • \(\alpha\) is the angle between the magnetic field and the normal to the coil.

The important idea is that an electric current interacting with a magnetic field produces a force, and the arrangement of those forces produces torque.

A brushless DC motor uses the same fundamental magnetic interaction, but changes how the magnetic fields are arranged.

Instead of having a rotating coil connected to brushes and a mechanical commutator, a typical brushless DC motor has:

  • Permanent magnets on the rotor.
  • Electromagnetic windings on the stationary stator.
  • An electronic controller that switches current between stator windings.

The controller creates a rotating magnetic field. The permanent-magnet rotor follows this changing field, producing rotation.

Side-by-side motor cross-sections: the BLDC has four alternating N/S permanent magnets on its central rotor and copper-wound stator poles; the SRM has wound stator poles around a six-tooth laminated-steel rotor with no magnets or windings.
Both motors place copper windings on the stator, but only the BLDC rotor carries permanent magnets; the SRM rotor is toothed steel.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

There is an important distinction involving electromagnetic induction.

As the permanent-magnet rotor turns, its magnetic field changes the magnetic flux passing through the stationary stator windings. Faraday’s law tells us that this changing flux induces an electromotive force (emf):

\[ \varepsilon=-N\frac{\Delta\Phi}{\Delta t} \]

This induced emf is called the back emf. It opposes the applied voltage and affects the current flowing through the motor.

However, back emf is not itself the direct cause of the motor’s torque. Torque comes from the interaction between the magnetic fields, while electromagnetic induction explains the voltage generated as the rotor moves.

This distinction is important when studying switched reluctance motors. They use electromagnetic induction too, but their torque-producing mechanism is different.

02What is magnetic reluctance?

Imagine trying to push water through two pipes.

One pipe is wide and offers little resistance to the flow. The other is narrow and makes it much harder to move the same amount of water through it.

A magnetic circuit has a similar property. Some paths allow magnetic flux to pass through easily, while others offer much greater opposition.

This opposition is called magnetic reluctance.

Magnetic reluctance depends on three main factors:

  • The length of the magnetic path.
  • The cross-sectional area of the path.
  • The magnetic permeability of the material.

For a simple uniform magnetic path:

\[ \mathcal R=\frac{\ell}{\mu A} \]

where:

  • \(\mathcal R\) is magnetic reluctance.
  • \(\ell\) is the length of the magnetic path in metres.
  • \(\mu\) is the magnetic permeability of the material.
  • \(A\) is the cross-sectional area in square metres.

A material with high magnetic permeability offers relatively little reluctance. A material with low permeability offers much greater reluctance.

This explains why iron is useful in electric motors. Iron has a much higher magnetic permeability than air, so magnetic flux can pass through it relatively easily.

The analogy with electrical resistance is useful, but there is a limitation: magnetic reluctance does not dissipate energy in the same way that an electrical resistor does. It describes opposition to magnetic flux, not electrical energy loss.

Why the air gap matters

Consider two pieces of iron separated by a small gap of air.

Even though the gap might be very small, it can contribute a large proportion of the total magnetic reluctance. This is because air has a much lower magnetic permeability than iron.

A switched reluctance motor takes advantage of this difference.

Its rotor and stator both have projecting teeth, called salient poles. When a rotor tooth moves into alignment with an energised stator pole, the overlap between the poles increases.

The effective magnetic path through the air gap becomes easier, and the total magnetic reluctance decreases.

The rotor is made from laminated ferromagnetic steel. It does not contain permanent magnets, but it becomes magnetised when the stator coils generate a magnetic field.

The magnetic field produces forces that pull the rotor teeth towards alignment with the energised stator poles.

This is the foundation of reluctance torque.

03How a switched reluctance motor produces rotation

A switched reluctance motor (SRM) has two main components:

Stator: The stationary outer section, containing several electromagnetic windings.

Rotor: The rotating inner section, containing projecting teeth made from ferromagnetic material.

Unlike a conventional permanent-magnet brushless motor, the rotor has no permanent magnets and no electrical windings.

The stator windings are arranged into separate groups called phases. An electronic controller switches these phases on and off according to the rotor’s position.

Consider a typical three-phase switched reluctance motor with six stator poles and four rotor poles.

The six stator poles form three opposite pairs, labelled A, B, and C.

The motor operates through a repeating sequence.

Step 1: Energise phase A.

Current flows through the phase A windings, producing a magnetic field around the corresponding stator poles.

The nearest rotor teeth are attracted towards these poles because this arrangement offers a lower-reluctance magnetic path.

The rotor begins rotating towards alignment.

Step 2: Switch phase A off and energise phase B.

Before phase A begins producing torque in the wrong direction, its current is reduced.

Phase B is then energised. Its magnetic field attracts the rotor towards a new alignment position.

The rotor continues rotating.

Step 3: Energise phase C.

Phase C creates another magnetic field and attracts the next available rotor teeth towards alignment.

The process repeats.

The sequence A → B → C produces rotation in one direction for this illustrative arrangement. Reversing the excitation sequence reverses the direction of rotation.

The electronic controller must know the rotor’s position to time these changes correctly. Position sensors, such as Hall sensors or encoders, can provide this information.

The switching process is called electronic commutation. It replaces the mechanical commutator used in traditional brushed motors.

The motor’s ability to produce torque without rotor magnets comes from something more specific than simply attracting iron.

We need to examine how inductance changes as the rotor moves.

04How changing inductance produces reluctance torque

Remember that magnetic flux is related to the strength of the magnetic field and the area through which the field passes.

For a coil with \(N\) turns, magnetic flux linkage is:

\[ \lambda=N\Phi \]

Here, \(\lambda\) is magnetic flux linkage, measured in weber-turns, and \(\Phi\) is the magnetic flux passing through one turn.

For a simple linear magnetic circuit, inductance is:

\[ L=\frac{\lambda}{i} \]

where \(L\) is inductance in henries (H), and \(i\) is the current through the winding in amperes.

Inductance describes how effectively a winding produces magnetic flux linkage for a given current.

Now consider what happens as the rotor moves.

When the rotor teeth are unaligned with the energised stator poles, the magnetic circuit has relatively high reluctance. Less flux linkage is produced for the same current.

Therefore, the phase inductance is relatively low.

As the rotor moves towards alignment, the magnetic reluctance decreases. More magnetic flux can pass through the magnetic circuit, increasing flux linkage.

The phase inductance increases.

At full alignment, inductance reaches a maximum.

The important relationship is:

  • Unaligned rotor: high reluctance and low inductance.
  • Partially aligned rotor: decreasing reluctance and increasing inductance.
  • Fully aligned rotor: low reluctance and maximum inductance.

Here is the crucial point:

The torque depends on how quickly inductance changes with rotor position, not simply on how large the inductance is.

A phase can have a very large inductance but produce zero instantaneous torque if the inductance is not changing as the rotor moves.

The torque equation

For a single phase operating under a simplified linear magnetic model, the electromagnetic torque is:

\[ \boxed{\tau=\frac{1}{2}i^2\frac{dL}{d\theta}} \]

This is the fundamental equation for understanding switched reluctance torque.

The symbols are:

  • \(\tau\): electromagnetic torque in newton metres (Nm).
  • \(i\): current through the stator phase in amperes.
  • \(L\): phase inductance in henries (H).
  • \(\theta\): rotor angular position in radians.
  • \(\frac{dL}{d\theta}\): rate of change of inductance with rotor position.

The equation shows two important relationships.

1. Torque depends on the square of current.

Because current is squared, reversing its direction does not reverse the torque.

For example:

\[ (+5)^2=(-5)^2=25 \]

The direction of the torque is therefore not determined by the direction of current.

This is quite different from the simple motor-effect model, where reversing the current in a conductor reverses the magnetic force.

2. Torque depends on the gradient of inductance.

The gradient tells us how inductance changes as the rotor moves.

There are three possible situations.

Inductance behaviourTorqueResult
Inductance increasingPositiveRotor accelerates in the positive angular direction
Inductance constantZeroNo instantaneous torque from that phase
Inductance decreasingNegativeRotor experiences torque in the negative angular direction

The rotor is therefore pulled towards increasing inductance.

Why does this equation work?

The formal explanation comes from energy conservation.

As the rotor moves towards alignment, the magnetic circuit becomes easier to magnetise. At constant current, the magnetic co-energy of a linear magnetic system is:

\[ W'=\frac{1}{2}Li^2 \]

Here, \(W'\) is magnetic co-energy, measured in joules.

Co-energy is an energy bookkeeping quantity used to calculate electromagnetic forces and torques. For a linear magnetic circuit, it has the same numerical value as the stored magnetic field energy.

The electromagnetic torque is the rate at which co-energy changes with angular position while current is held constant:

\[ \tau=\left(\frac{\partial W'}{\partial\theta}\right)_i \]

Substituting the expression for co-energy:

\[ \tau=\frac{\partial}{\partial\theta} \left(\frac{1}{2}Li^2\right) \]

Because current is constant during this calculation:

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

This gives us the reluctance torque equation.

The power supply provides the electrical energy needed to establish the magnetic field and maintain the current. Some of that energy is converted into mechanical work as the rotor moves.

The full mathematical treatment uses magnetic co-energy and flux-linkage characteristics. The simplified derivation above is sufficient to understand the main physical mechanism.

05Where electromagnetic induction fits into an SRM

We have established that reluctance torque comes from the tendency of the rotor to move towards increasing inductance.

But electromagnetic induction is still an important part of the motor’s operation.

Remember Faraday’s law:

\[ \varepsilon=-\frac{d\lambda}{dt} \]

An emf is induced whenever the magnetic flux linkage of a winding changes.

In a switched reluctance motor, flux linkage depends on both the current and the rotor position:

\[ \lambda=L(\theta)i \]

Therefore, flux linkage can change for two reasons:

  1. The current through the winding changes.
  2. The rotor moves, changing the inductance of the winding.

Using the product rule for differentiation:

\[ \frac{d\lambda}{dt} = L\frac{di}{dt} +i\frac{dL}{d\theta}\frac{d\theta}{dt} \]

Since angular velocity is:

\[ \omega=\frac{d\theta}{dt} \]

the simplified phase voltage equation becomes:

\[ \boxed{ v=Ri+L\frac{di}{dt} +i\omega\frac{dL}{d\theta} } \]

where:

  • \(v\) is the applied phase voltage in volts.
  • \(R\) is the winding resistance in ohms.
  • \(i\) is phase current in amperes.
  • \(L\) is phase inductance in henries.
  • \(\omega\) is rotor angular velocity in radians per second.
  • \(\theta\) is rotor angular position in radians.

This equation assumes a linear magnetic circuit, so that \(L\) depends on rotor position but not on current.

The final term,

\[ i\omega\frac{dL}{d\theta} \]

represents the motion-induced voltage contribution.

As the rotor moves and inductance changes, flux linkage changes even if the current remains constant. This produces an induced emf.

During normal motoring operation, this voltage contribution acts as a back-emf term that the supply must overcome to maintain the phase current.

Notice something interesting: the same inductance gradient appears in both the torque equation and the voltage equation.

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

\[ e_{\mathrm{mot}}=i\omega\frac{dL}{d\theta} \]

The two equations describe different effects of the changing magnetic circuit.

  • The torque equation describes mechanical energy conversion.
  • The voltage equation describes electromagnetic induction in the stator winding.

They are connected, but an induced emf is not the direct cause of reluctance torque.

This is also why an SRM should not be confused with a conventional induction motor. Its intended torque-producing mechanism does not rely on induced currents in a rotor winding.

For further background, Self-Inductance: How Coils Oppose Changes in Current explains the induced emf associated with changing current. RL Circuits: Understanding Current Growth and Decay develops the related current response.

06An important limitation: real motors are not perfectly linear

The torque equation is extremely useful, but it makes some simplifying assumptions.

In a real switched reluctance motor, the iron core can experience magnetic saturation.

As current increases, the magnetic domains in the iron become increasingly aligned. Eventually, increasing the current produces a smaller increase in magnetic flux than it did at lower currents.

Consequently, inductance is not perfectly constant for a given rotor position. It depends on both current and rotor position:

\[ L=L(i,\theta) \]

The simple torque equation is then no longer an exact description of the motor.

Engineers use the more general co-energy relationship:

\[ \tau=\left(\frac{\partial W'}{\partial\theta}\right)_i \]

where co-energy is calculated from the actual relationship between flux linkage, current, and rotor position.

Other complications include:

  • Magnetic flux leakage and fringing.
  • Interaction between neighbouring phases.
  • Electrical resistance and heating.
  • Eddy-current and hysteresis losses.
  • Delays in switching the phase current.

These effects influence the motor’s efficiency, noise, vibration, and torque smoothness.

The linear model remains valuable because it reveals the central physical principle without requiring advanced electromagnetic field calculations.

For a more detailed engineering treatment, see the RWTH Aachen University dissertation on efficiency-optimised switched reluctance machines.

07Worked example: Calculating reluctance torque from changing inductance

A switched reluctance motor has a phase current of 8.0 A. As the rotor moves towards alignment through an angular displacement of 20°, the phase inductance increases from 12 mH to 30 mH.

Assuming constant current and a linear magnetic circuit, calculate the average electromagnetic torque produced over this movement.

Step 1

We know the current and the change in inductance.

For constant current, the change in magnetic co-energy is:

\[ \Delta W'=\frac{1}{2}i^2\Delta L \]

The average torque is the change in co-energy divided by the angular displacement:

\[ \tau_{\mathrm{avg}}=\frac{\Delta W'}{\Delta\theta} \]

Step 2

\[ \Delta L=30-12=18\text{ mH} \]

Converting to henries:

\[ \Delta L=0.018\text{ H} \]

Step 3

Torque calculations require angular displacement in radians.

\[ \Delta\theta=20^\circ\times\frac{\pi}{180^\circ} \]

\[ \Delta\theta=0.349\text{ rad} \]

Step 4

Substitute the current and inductance change:

\[ \begin{aligned} \Delta W' &=\frac{1}{2}(8.0)^2(0.018)\\ &=0.576\text{ J} \end{aligned} \]

Step 5

\[ \tau_{\mathrm{avg}} =\frac{0.576}{0.349} \]

\[ \boxed{\tau_{\mathrm{avg}}=1.65\text{ Nm}} \]

The motor produces an average reluctance torque of 1.65 Nm towards alignment.

Notice that the torque is positive because inductance increases as the rotor moves in the chosen positive angular direction.

This result assumes constant current, negligible magnetic saturation, and no significant interaction with other phases.

08Worked example: Calculating torque and induced emf together

A switched reluctance motor is operating with a phase current of 6.0 A. The rotor rotates at an angular velocity of 80 rad/s.

At the current rotor position, the inductance gradient is:

\[ \frac{dL}{d\theta}=0.025\text{ H/rad} \]

The winding resistance is 0.40 Ω.

Assuming a linear magnetic circuit and constant phase current, calculate:

  • The electromagnetic torque.
  • The magnitude of the motion-induced voltage.
  • The applied terminal voltage required to maintain the current.

Step 1

Use:

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

Substitute:

\[ \begin{aligned} \tau &=\frac{1}{2}(6.0)^2(0.025)\\ &=0.45\text{ Nm} \end{aligned} \]

The electromagnetic torque is 0.45 Nm in the positive direction.

Step 2

Use:

\[ e_{\mathrm{mot}}=i\omega\frac{dL}{d\theta} \]

Substitute:

\[ \begin{aligned} e_{\mathrm{mot}} &=(6.0)(80)(0.025)\\ &=12\text{ V} \end{aligned} \]

The magnitude of the motion-induced voltage contribution is 12 V.

Because inductance is increasing as the rotor moves, this contribution acts as a back-emf voltage drop in the motor’s terminal equation.

Step 3

The general equation is:

\[ v=Ri+L\frac{di}{dt}+e_{\mathrm{mot}} \]

The current is constant, so:

\[ \frac{di}{dt}=0 \]

Therefore:

\[ v=Ri+e_{\mathrm{mot}} \]

Substitute:

\[ \begin{aligned} v&=(0.40)(6.0)+12\\ &=2.4+12\\ &=14.4\text{ V} \end{aligned} \]

\[ \boxed{v=14.4\text{ V}} \]

The supply needs to provide 14.4 V to maintain the specified current under these simplified conditions.

The important observation is that the same changing inductance produces both reluctance torque and a motion-induced voltage.

If the rotor speed doubles while current and inductance gradient remain unchanged, the motion-induced voltage doubles. The torque, however, remains unchanged.

This is because the simplified torque equation depends on current and inductance gradient, not angular velocity.

09Questions and solutions

Question 1

A switched reluctance motor has one energised stator phase carrying a current of 5.0 A.

At a particular rotor position, the phase inductance increases at a rate of 0.018 H/rad as the rotor moves in the positive angular direction.

Calculate the instantaneous electromagnetic torque and state its direction.

Solution 1

The instantaneous torque is 0.225 Nm in the positive angular direction.

The inductance is increasing, so the rotor experiences positive reluctance torque.

Using:

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

Substitute:

\[ \begin{aligned} \tau &=\frac{1}{2}(5.0)^2(0.018)\\ &=0.225\text{ Nm} \end{aligned} \]

\[ \boxed{\tau=0.225\text{ Nm}} \]

The positive sign indicates that the torque acts in the direction of increasing angular position.

The result does not depend on whether the current is positive or negative because current is squared.

Question 2

A rotor is being held at two different positions by the same energised stator phase.

At position P, the rotor teeth are fully aligned with the stator poles. The phase inductance is 28 mH, and its instantaneous gradient is zero.

At position Q, the rotor is partially aligned, and the phase inductance gradient is \(+0.025\text{ H/rad}\).

The phase current is 7.0 A at both positions.

A student argues that position P must produce greater torque because it has a larger inductance.

Evaluate this claim by calculating the torque at both positions. Explain what happens if the rotor is displaced slightly from position P while the phase remains energised.

Solution 2

Position Q produces greater instantaneous torque. Position P produces zero instantaneous torque, despite having the larger inductance.

The student’s mistake is confusing the magnitude of inductance with its rate of change.

At position P, the inductance is at its maximum. Its gradient is zero.

Therefore:

\[ \tau_P=\frac{1}{2}(7.0)^2(0) \]

\[ \boxed{\tau_P=0\text{ Nm}} \]

At position Q, the inductance gradient is positive.

\[ \tau_Q=\frac{1}{2}(7.0)^2(0.025) \]

\[ \boxed{\tau_Q=0.6125\text{ Nm}} \]

Position Q produces a torque of 0.6125 Nm.

Now consider a small displacement away from position P.

Because P is the aligned position and corresponds to maximum inductance, moving slightly in either direction reduces the inductance.

The resulting torque acts back towards P.

Therefore, position P is a stable equilibrium position for that energised phase, even though the instantaneous torque at exact alignment is zero.

This is an important distinction: a magnetic field can hold a rotor in a stable position without producing continuous rotational torque.

Question 3

A switched reluctance motor is rotating in the positive angular direction at 100 rad/s.

One stator phase carries a current of 6.0 A. At the current rotor position:

\[ \frac{dL}{d\theta}=-0.020\text{ H/rad} \]

Calculate:

  • The electromagnetic torque.
  • The magnitude of the motion-induced voltage contribution.

Explain whether the motor is operating in its normal motoring region or producing braking torque. State what happens to the energy if the power converter allows it to return to the DC supply.

Solution 3

The electromagnetic torque is -0.36 Nm, so the motor produces braking torque. The magnitude of the motion-induced voltage contribution is 12 V.

The negative inductance gradient indicates that inductance is decreasing as the rotor moves in the positive angular direction.

First, calculate torque:

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

\[ \begin{aligned} \tau &=\frac{1}{2}(6.0)^2(-0.020)\\ &=-0.36\text{ Nm} \end{aligned} \]

\[ \boxed{\tau=-0.36\text{ Nm}} \]

The negative sign means the torque acts opposite to the current direction of rotation.

Next, calculate the signed motion-induced voltage contribution:

\[ e_{\mathrm{mot}}=i\omega\frac{dL}{d\theta} \]

\[ \begin{aligned} e_{\mathrm{mot}} &=(6.0)(100)(-0.020)\\ &=-12\text{ V} \end{aligned} \]

Its magnitude is:

\[ \boxed{|e_{\mathrm{mot}}|=12\text{ V}} \]

The machine is operating in a generating or braking region rather than its normal motoring region.

The rotor is moving in the positive direction, but the electromagnetic torque acts in the negative direction.

If the converter provides a suitable energy-return path, electrical energy can be transferred back to the DC supply. Otherwise, some of the energy may be dissipated as heat in the electrical circuit.

This demonstrates that a switched reluctance motor can also operate as a generator. The direction of energy conversion depends on rotor motion, inductance variation, and phase excitation.

Question 4

A single stator phase has the following inductance values as the rotor moves in the positive angular direction:

Rotor anglePhase inductance
10°10 mH
25°26 mH
40°14 mH

The phase current is approximately 4.0 A throughout this movement.

At 25°, the controller commands the phase to switch off. However, the current decays slowly and remains approximately 4.0 A until the rotor reaches 40°.

Assume a linear magnetic circuit and constant current over each interval.

Calculate:

  • The average torque between 10° and 25°.
  • The average torque between 25° and 40°.
  • The total mechanical work produced by this phase over the complete 10° to 40° movement.

Explain why switching the phase off at 25° does not immediately eliminate its torque.

Solution 4

The first interval produces approximately +0.489 Nm, the second produces approximately -0.367 Nm, and the total mechanical work is 0.032 J.

The important issue is that the current remains in the winding after the switch-off command. The rotor therefore continues experiencing reluctance torque while the inductance decreases.

First, convert the angular displacement of each interval into radians.

\[ 15^\circ\times\frac{\pi}{180^\circ} =0.2618\text{ rad} \]

First interval: 10° to 25°

The inductance increases from 10 mH to 26 mH.

\[ \Delta L=0.026-0.010=0.016\text{ H} \]

The change in co-energy is:

\[ \Delta W'_1=\frac{1}{2}i^2\Delta L \]

\[ \begin{aligned} \Delta W'_1 &=\frac{1}{2}(4.0)^2(0.016)\\ &=0.128\text{ J} \end{aligned} \]

Average torque:

\[ \tau_1=\frac{0.128}{0.2618} \]

\[ \boxed{\tau_1=+0.489\text{ Nm}} \]

The positive torque helps the rotor move towards alignment.

Second interval: 25° to 40°

The inductance now decreases from 26 mH to 14 mH.

\[ \Delta L=0.014-0.026=-0.012\text{ H} \]

The change in co-energy is:

\[ \begin{aligned} \Delta W'_2 &=\frac{1}{2}(4.0)^2(-0.012)\\ &=-0.096\text{ J} \end{aligned} \]

Average torque:

\[ \tau_2=\frac{-0.096}{0.2618} \]

\[ \boxed{\tau_2=-0.367\text{ Nm}} \]

The negative torque opposes the rotor’s positive rotation.

Total mechanical work

Add the work contributions from both intervals:

\[ W_{\mathrm{total}}=0.128-0.096 \]

\[ \boxed{W_{\mathrm{total}}=0.032\text{ J}} \]

The phase produces positive net work over the complete movement, but the negative torque after 25° removes much of the useful work produced earlier.

The controller must therefore begin reducing the current before the inductance starts falling.

Opening a switch does not instantly make an inductor’s current zero. The winding resists sudden changes in current, so a controlled demagnetisation process is needed.

This is why the timing of electronic commutation is so important.

Question 5

A three-phase switched reluctance motor is operating near a phase transition.

At a particular rotor position \(\theta_0\), the three phases have the following characteristics:

PhaseInductance gradientCurrent
A0 H/rad-8.0 A
B-0.030 H/rad+4.0 A
C+0.020 H/rad+5.0 A

Phase A is exactly aligned with the rotor. Phase B is being energised to produce rotation in the negative angular direction. Phase C still carries residual current because its previous excitation has not completely decayed.

Assume:

  • The magnetic circuits are linear and unsaturated.
  • Mutual inductance between phases is negligible.
  • The listed inductance gradients remain approximately constant over a small rotor displacement.
  • Friction and external load torque are negligible.

A controller attempts to reverse the motor by reversing the current in phase A and energising phase B.

(a) Calculate the instantaneous torque produced by each phase and the total electromagnetic torque.

(b) Determine the initial direction of rotation.

(c) Calculate the minimum magnitude of phase B current required to produce negative net torque while phase C continues carrying 5.0 A.

(d) Explain why reversing the current in phase A or phase B does not, by itself, determine the direction of rotation. Describe what the controller must do to achieve reliable reverse operation.

Solution 5

The total instantaneous torque is +0.010 Nm, so the rotor initially experiences torque in the positive direction. Phase B needs a current magnitude greater than approximately 4.08 A to overcome the residual positive torque from phase C.

This problem combines three important ideas:

  • Torque depends on the inductance gradient.
  • Current polarity does not determine reluctance torque direction.
  • Simultaneously energised phases can produce opposing torques.

(a) Calculate the torque from each phase.

For independent phases, the total torque is approximately:

\[ \tau_{\mathrm{total}} = \frac{1}{2}\sum_k i_k^2 \frac{dL_k}{d\theta} \]

Start with phase A.

Its inductance gradient is zero because the rotor is exactly aligned.

\[ \tau_A=\frac{1}{2}(-8.0)^2(0) \]

\[ \boxed{\tau_A=0\text{ Nm}} \]

The negative current does not matter because it is squared.

For phase B:

\[ \tau_B=\frac{1}{2}(4.0)^2(-0.030) \]

\[ \boxed{\tau_B=-0.240\text{ Nm}} \]

Phase B produces negative torque, as intended.

For phase C:

\[ \tau_C=\frac{1}{2}(5.0)^2(0.020) \]

\[ \boxed{\tau_C=+0.250\text{ Nm}} \]

Phase C produces positive torque, opposing the attempted reversal.

Add all three contributions:

\[ \begin{aligned} \tau_{\mathrm{total}} &=0-0.240+0.250\\ &=+0.010\text{ Nm} \end{aligned} \]

\[ \boxed{\tau_{\mathrm{total}}=+0.010\text{ Nm}} \]

(b) Determine the initial direction.

The initial torque is positive.

Therefore, the rotor initially experiences torque in the positive angular direction, despite phase B being energised to reverse the motor.

The tempting prediction is that energising the reverse phase must immediately reverse rotation.

However, phase C has not finished demagnetising. Its residual current produces slightly more positive torque than phase B produces negative torque.

The interaction between phases determines the actual result.

(c) Calculate the minimum phase B current.

Let the required phase B current magnitude be \(I_B\).

For negative net torque, the magnitude of phase B’s negative torque must exceed phase C’s positive torque.

Therefore:

\[ \frac{1}{2}I_B^2(0.030) > \frac{1}{2}(5.0)^2(0.020) \]

Cancel the common factor of one-half:

\[ 0.030I_B^2>0.500 \]

Rearrange:

\[ I_B^2>\frac{0.500}{0.030} \]

\[ I_B^2>16.67 \]

Taking the square root:

\[ I_B>4.08\text{ A} \]

Thus:

\[ \boxed{I_B>4.08\text{ A}} \]

A current of exactly 4.08 A would produce approximately zero net torque. A slightly larger current is required for negative net torque.

(d) Explain why reversing current does not reverse the motor.

The key relationship is:

\[ \tau=\frac{1}{2}i^2\frac{dL}{d\theta} \]

Reversing the current changes its sign, but not its square.

Consequently:

  • Reversing phase A does not produce torque at its exact aligned position.
  • Reversing phase B does not change its negative torque into positive torque.
  • Reversing the motor requires changing which stator phases are energised and when they are energised.

The controller must also account for residual current in the outgoing phase. Simply switching on the reverse phase may not immediately produce reverse torque if the previous phase continues generating torque in the original direction.

For reliable reversal, the controller must manage the outgoing phase current, establish sufficient torque from the incoming phase, and then continue switching the phases in the reverse sequence.

This is the deeper principle: the direction of rotation is determined by the position-dependent inductance of the energised phases and their combined torque, not by the polarity of the current.

10Where this leads next

Switched reluctance motors show that permanent magnets are not essential for producing electromagnetic torque.

The key is to create a magnetic field whose reluctance changes as the rotor moves, then switch the stator windings at the correct rotor positions.

The next useful concept is the relationship between inductance, current decay, and switching time. An SRM controller must predict when to energise a phase, when to reduce its current, and how to prevent unwanted negative torque.

That connects reluctance torque directly to self-inductance and RL circuit behaviour, and explains why the electrical controller is just as important as the motor’s physical construction.