Why Diffraction Gratings Produce Sharper Maxima Than Two Slits
Discover why diffraction gratings produce much narrower, sharper bright maxima than two-slit arrangements. Learn how the number of illuminated slits affects interference, distinguish slit width from slit spacing, and practise with worked HSC Physics examples.
Put a monochromatic laser through two narrow slits, then replace the mask with a diffraction grating containing hundreds of slits. If both arrangements have the same distance between neighbouring slit centres, their principal bright maxima appear at the same angles. Yet the grating produces much narrower, sharper maxima.
Why? Because a small phase difference between two waves does not immediately destroy their constructive interference. With hundreds of waves, however, that same phase difference accumulates across the array. The contributions quickly spread out of phase and cancel.
That is the key difference between two-slit interference and diffraction grating interference: more illuminated slits make the principal maxima much narrower.
01Set up a fair comparison
To understand the difference, imagine a controlled experiment using two interchangeable masks.
The first mask has two identical narrow slits. The second has hundreds of equally spaced slits.
Both masks have:
- The same distance \(d\) between neighbouring slit centres.
- The same individual slit width \(a\).
- Normally incident monochromatic light.
- Coherent illumination, so the waves reaching the slits maintain a fixed phase relationship.
The only important difference is the number of illuminated slits, \(N\).
The light travels from the laser, through the collimating lens, and towards the aperture mask. After passing through the mask, it spreads into different directions.
A converging lens collects this light and focuses each outgoing direction onto a different position on the screen. A ray travelling at angle \(\theta\) to the grating normal reaches a position:
\[ x=f\tan\theta \]
where \(f\) is the focal length of the lens.
This arrangement is useful because the screen displays the far-field diffraction pattern without requiring an enormous distance between the grating and the screen.
A simpler experiment could place a screen directly behind the mask. However, if the screen is too close, the outgoing rays cannot be treated as approximately parallel when calculating their path differences. Near-field effects can then complicate the pattern.
Using a collimated beam and a lens at the observation end provides a cleaner test of the far-field model.
What should the experiment show?
Before looking at the difference in peak width, consider where the bright maxima should appear.
For normally incident light, the path difference between waves from neighbouring slits is
\[ \Delta L=d\sin\theta \]
Constructive interference occurs when this path difference is a whole number of wavelengths:
\[ \boxed{d\sin\theta=m\lambda} \]
Here:
- \(d\) is the centre-to-centre separation of neighbouring slits, in metres.
- \(\theta\) is the angle measured from the grating normal.
- \(m\) is the diffraction order, taking integer values \(0,\pm1,\pm2,\ldots\).
- \(\lambda\) is the wavelength of the light, in metres.
The central maximum has \(m=0\). The first-order maxima have \(m=\pm1\), and the second-order maxima have \(m=\pm2\).
This is the same principal constructive-interference condition used for two slits.
If the slit spacing \(d\) and wavelength \(\lambda\) remain unchanged, the maxima must occur at the same angles in both experiments.
The number of slits does not change this equation.
For a refresher on deciding which interference equation to use, see Double-Slit vs Diffraction Grating: Choosing the Right Equation.
02Why more slits produce sharper maxima
The important difference appears when you move slightly away from a principal maximum.
First, picture the physical arrangement.
Each slit produces a wave that travels towards the observation point. The distance between neighbouring slits is \(d\), measured between their centres. The number of slits contributing to the pattern is \(N\).
At a principal maximum, all the waves arrive in phase.
Imagine that every wave reaches the observation point with a crest at exactly the same time. Their amplitudes reinforce one another, producing a bright maximum.
Now move the observation point slightly to one side.
The path difference between neighbouring slits changes. Their waves no longer arrive perfectly in phase.
For two slits, there are only two contributions to compare. A small phase difference still allows substantial constructive interference.
For a grating, the situation is different.
Each successive slit introduces another phase difference. The wave from the third slit is shifted relative to the second, the fourth is shifted relative to the third, and so on.
The phase difference accumulates across the entire array.
Eventually, the waves point in sufficiently different phase directions that their amplitudes cancel.
This cancellation happens very quickly when hundreds of slits contribute.
Understanding the phase difference
The phase difference between waves from neighbouring slits is
\[ \delta=\frac{2\pi d\sin\theta}{\lambda} \]
where \(\delta\) is measured in radians.
At a principal maximum,
\[ \delta=2\pi m \]
Every neighbouring pair is in phase.
Consider what happens at the first minimum next to the central maximum.
For two slits, the waves cancel when their phase difference is \(180^\circ\), or \(\pi\) radians.
That requires a path difference of
\[ \Delta L=\frac{\lambda}{2} \]
For a grating containing \(N\) equally spaced slits, complete cancellation occurs much sooner.
If the phase difference between neighbouring slits is \(360^\circ/N\), the \(N\) wave contributions are evenly distributed around a complete phase cycle.
Their vector sum is zero.
Therefore, the path difference between neighbouring slits at the first minimum is
\[ \Delta L=\frac{\lambda}{N} \]
This is the crucial result.
For the central maximum, the first minimum satisfies
\[ \boxed{d\sin\theta=\frac{\lambda}{N}} \]
The same reasoning applies around any principal maximum. The nearest minima occur when
\[ d\sin\theta= \left(m\pm\frac{1}{N}\right)\lambda \]
The important point is that the path difference only needs to change by \(\lambda/N\) from a principal maximum to reach the nearest minimum.
For two slits, that change is \(\lambda/2\).
For 100 slits, it is only \(\lambda/100\).
The phasor representation makes the difference easier to picture.
A phasor is a rotating-vector representation of a wave’s amplitude and phase. Waves that are in phase point in the same direction, so their vectors add. Waves with different phases point in different directions and can partially or completely cancel.
With many slits, even a small phase difference between neighbours can spread the vectors around the full circle.
That is why a grating’s intensity falls so sharply when you move away from a principal maximum.
Comparing the peak widths
For the central maximum, the angular distance from the centre to the first minimum is
\[ \theta_{\min} = \sin^{-1}\left(\frac{\lambda}{Nd}\right) \]
The full angular width of the central maximum, measured between its two nearest minima, is therefore
\[ \boxed{ \Delta\theta = 2\sin^{-1}\left(\frac{\lambda}{Nd}\right) } \]
When the angle is small, we can use
\[ \sin\theta\approx\theta \]
provided \(\theta\) is measured in radians.
The full angular width then becomes approximately
\[ \boxed{ \Delta\theta\approx\frac{2\lambda}{Nd} } \]
Notice what this tells us.
If \(d\) and \(\lambda\) remain constant, increasing \(N\) makes the maximum narrower in inverse proportion to the number of illuminated slits.
| Number of illuminated slits | Path difference at first minimum |
|---|---|
| \(N=2\) | \(\lambda/2\) |
| \(N=10\) | \(\lambda/10\) |
| \(N=50\) | \(\lambda/50\) |
| \(N=100\) | \(\lambda/100\) |
| \(N=1000\) | \(\lambda/1000\) |
The maxima occur at the same principal angles, but the grating’s maxima become increasingly narrow.
One detail is worth noticing: a grating also produces small secondary maxima between its principal maxima. These are much weaker than the main peaks.
The important comparison is between the widths of the principal maxima, not a claim that every other part of the grating pattern is completely dark.
Worked example: Compare two slits with a 100-slit grating
A monochromatic laser has a wavelength of \(600\text{ nm}\). It illuminates two different masks.
Both masks have a centre-to-centre slit spacing of \(20.0\text{ μm}\).
Mask A contains two illuminated slits, while Mask B contains 100 illuminated slits.
Calculate the full angular width of the central principal maximum for each mask. Assume the single-slit diffraction envelope does not restrict the central maximum.
Step 1
For the central maximum, the first minimum occurs when
\[ d\sin\theta=\frac{\lambda}{N} \]
Rearranging,
\[ \sin\theta=\frac{\lambda}{Nd} \]
Step 2
\[ \lambda=600\times10^{-9}\text{ m} \]
\[ d=20.0\times10^{-6}\text{ m} \]
Step 3
For two slits, \(N=2\).
\[ \sin\theta = \frac{600\times10^{-9}} {2(20.0\times10^{-6})} \]
\[ \sin\theta=0.0150 \]
Therefore,
\[ \theta=\sin^{-1}(0.0150) \]
\[ \theta=0.859^\circ \]
The pattern is symmetric about the central maximum, so the full width is
\[ \Delta\theta=2(0.859^\circ) \]
\[ \boxed{\Delta\theta=1.72^\circ} \]
Step 4
For 100 slits, \(N=100\).
\[ \sin\theta = \frac{600\times10^{-9}} {100(20.0\times10^{-6})} \]
\[ \sin\theta=0.000300 \]
Therefore,
\[ \theta=\sin^{-1}(0.000300) \]
\[ \theta=0.0172^\circ \]
The full angular width is
\[ \Delta\theta=2(0.0172^\circ) \]
\[ \boxed{\Delta\theta=0.0344^\circ} \]
Step 5
\[ \frac{1.72}{0.0344}=50 \]
The 100-slit grating produces a central maximum that is 50 times narrower than the two-slit arrangement.
This is exactly what we expect because the grating has 50 times as many illuminated slits.
Both masks produce maxima at the same principal angles. The difference is how quickly destructive interference develops when we move away from those angles.
Both calculated angles are small, so the small-angle approximation would also have been suitable. Using the inverse sine above gives the more precise results.
03Slit width, slit spacing, and number of slits are different
There is another important distinction.
Students sometimes assume that a grating produces sharper maxima because its individual slits are narrower than those in a double-slit arrangement.
That is not the reason.
Three quantities control different parts of the pattern.
| Quantity | Meaning | What it controls |
|---|---|---|
| \(d\) | Centre-to-centre slit spacing | Positions of principal interference maxima |
| \(a\) | Width of each individual slit | The broad single-slit diffraction envelope |
| \(N\) | Number of illuminated slits | Narrowness of the principal interference maxima |
The distinction between \(a\) and \(d\) is particularly important.
The spacing \(d\) is measured between the centres of neighbouring slits. It is not the empty gap between them.
If each slit has width \(a\), the gap between neighbouring slit edges is \(d-a\).
What happens if you change the slit width?
Each individual slit produces diffraction.
For a rectangular slit, the first minimum of its single-slit diffraction envelope occurs when
\[ a\sin\theta=\lambda \]
More generally, the minima satisfy
\[ a\sin\theta=p\lambda \]
where \(p\) is a non-zero integer.
Reducing the slit width \(a\) makes the individual slit diffraction envelope wider.
However, it does not change the positions or intrinsic widths of the principal grating maxima if \(d\) and \(N\) remain unchanged.
This means more interference orders may fit inside the broader envelope, but the principal peaks are not automatically sharper.
That is a useful way to diagnose a question:
- If the question changes \(d\), investigate the positions of the principal maxima.
- If it changes \(a\), investigate the single-slit diffraction envelope.
- If it changes \(N\), investigate the sharpness of the principal maxima.
Worked example: Does narrowing each slit sharpen the grating?
Two diffraction gratings each contain 60 illuminated slits with a centre-to-centre spacing of \(8.0\text{ μm}\).
Grating A has individual slit widths of \(4.0\text{ μm}\).
Grating B has individual slit widths of \(2.0\text{ μm}\).
Both use light with a wavelength of \(500\text{ nm}\).
Determine whether either grating produces narrower principal maxima. Also determine whether the second-order maximum is suppressed by the single-slit diffraction envelope in either arrangement.
Step 1
Both gratings have
\[ N=60 \]
and
\[ d=8.0\times10^{-6}\text{ m} \]
The first-minimum condition for the central maximum is
\[ d\sin\theta=\frac{\lambda}{N} \]
Since \(d\), \(N\), and \(\lambda\) are identical, both gratings have the same principal peak width.
Neither grating produces intrinsically sharper interference maxima.
Step 2
Its slit width is
\[ a=4.0\times10^{-6}\text{ m} \]
The first envelope minimum satisfies
\[ a\sin\theta=\lambda \]
Therefore,
\[ \sin\theta = \frac{500\times10^{-9}} {4.0\times10^{-6}} \]
\[ \sin\theta=0.125 \]
Step 3
The grating equation is
\[ d\sin\theta=m\lambda \]
For the second order, \(m=2\).
\[ \sin\theta = \frac{2(500\times10^{-9})} {8.0\times10^{-6}} \]
\[ \sin\theta=0.125 \]
This is exactly the same angle as the first single-slit minimum.
Therefore, Grating A has a missing second order: the single-slit envelope suppresses the second-order interference maximum.
Step 4
Its slit width is
\[ a=2.0\times10^{-6}\text{ m} \]
The first envelope minimum occurs at
\[ \sin\theta = \frac{500\times10^{-9}} {2.0\times10^{-6}} \]
\[ \sin\theta=0.250 \]
The second-order grating maximum is still at
\[ \sin\theta=0.125 \]
This is no longer at an envelope minimum.
Therefore, Grating B can display its second-order maximum.
The important result is that narrowing the slits changes the overall diffraction envelope, not the sharpness of the interference maxima.
04What determines how many slits actually contribute?
A grating might have thousands of lines engraved across its surface. However, the number of lines that matters for peak sharpness is the number illuminated by the incoming beam.
Suppose a grating has a line density \(n\), measured in lines per metre, and the incoming beam illuminates a width \(W\).
The approximate number of illuminated slits is
\[ N=nW \]
The slit spacing is
\[ d=\frac{1}{n} \]
Combining these expressions gives
\[ Nd\approx W \]
This is useful because it connects the physical width of the illuminated grating to the angular width of its principal maxima.
For the central maximum,
\[ \sin\theta_{\min} = \frac{\lambda}{Nd} \]
Therefore,
\[ \sin\theta_{\min}\approx\frac{\lambda}{W} \]
A wider illuminated section generally produces a narrower central maximum.
This is why illuminating more of the same grating can improve the sharpness of its interference pattern.
It also explains why counting every line printed on a grating is a mistake. Only the lines receiving the coherent incident light contribute to the observed pattern.
05What the experiment can and cannot show
The predicted comparison gives strong evidence for the role of coherent superposition.
If the two-slit and many-slit arrangements have the same spacing, their principal maxima occur at the same angles. The many-slit arrangement produces narrower maxima because the phase mismatch accumulates across more contributions.
However, the ideal comparison relies on several assumptions.
The light must remain coherent across the illuminated grating.
If the waves reaching different slits do not maintain a stable phase relationship, the contributions cannot produce the same sharp interference maxima.
The slits must be regularly spaced.
Spacing errors disturb the phase relationship and can broaden the observed maxima or reduce their contrast.
The illumination should be reasonably uniform.
If some slits receive much more light than others, the cancellation between contributions becomes less complete.
The detector must have sufficient resolution.
A very narrow maximum can appear broad if the detector pixels are too large or the optical system cannot distinguish such small angular differences.
There is also an important distinction between peak sharpness and absolute brightness.
A grating can concentrate light into narrow, intense principal maxima, but the measured brightness also depends on the laser power, the number of illuminated slits, the slit widths, and the transmission of the apparatus.
The experiment is testing the shape of the interference pattern, not claiming that adding more slits creates additional light.
06Questions and solutions
Question 1
A monochromatic laser with a wavelength of \(500\text{ nm}\) illuminates a diffraction grating containing 50 equally spaced illuminated slits.
The centre-to-centre slit spacing is \(8.0\text{ μm}\).
Calculate:
a) The angle between the central maximum and the first minimum.
b) The full angular width of the central principal maximum.
Assume normal incidence and ignore the single-slit diffraction envelope.
Solution 1
a) The first minimum occurs at approximately \(0.0716^\circ\) from the central maximum.
b) The full angular width is approximately \(0.143^\circ\).
For the first minimum around the central maximum,
\[ d\sin\theta=\frac{\lambda}{N} \]
Rearranging,
\[ \sin\theta=\frac{\lambda}{Nd} \]
Substitute the given values:
\[ \sin\theta = \frac{500\times10^{-9}} {50(8.0\times10^{-6})} \]
\[ \sin\theta=0.00125 \]
Therefore,
\[ \theta=\sin^{-1}(0.00125) \]
\[ \theta=0.0716^\circ \]
The pattern is symmetrical about the central maximum, so the full angular width is
\[ \Delta\theta=2(0.0716^\circ) \]
\[ \boxed{\Delta\theta=0.143^\circ} \]
Remember that the calculated angle is only the distance from the central maximum to one first minimum. The question asks for the full width, so you must double it.
Question 2
A diffraction grating has 1200 lines per millimetre.
A coherent laser beam initially illuminates a width of \(0.25\text{ mm}\) of the grating. The wavelength is \(500\text{ nm}\).
The beam width is then increased to \(0.50\text{ mm}\), without changing the grating, wavelength, or angle of incidence.
A screen is positioned \(2.0\text{ m}\) away, and the far-field approximation is valid.
For both beam widths, calculate:
a) The number of illuminated slits.
b) The angular distance from the central maximum to the first minimum.
c) The full width of the central maximum on the screen.
Explain why increasing the illuminated width changes the result.
Solution 2
Doubling the illuminated width doubles the number of contributing slits and halves the angular width of the central maximum.
The initial pattern has a full screen width of approximately \(8.0\text{ mm}\). The expanded beam produces a full width of approximately \(4.0\text{ mm}\).
Step 1: Calculate the grating spacing.
The line density is
\[ n=1200\times1000 \]
\[ n=1.20\times10^6\text{ m}^{-1} \]
Therefore,
\[ d=\frac{1}{n} \]
\[ d=8.33\times10^{-7}\text{ m} \]
Step 2: Calculate the number of illuminated slits initially.
For an illuminated width of \(0.25\text{ mm}\),
\[ N=nW \]
\[ N=1200(0.25) \]
\[ \boxed{N=300} \]
Step 3: Calculate the initial first-minimum angle.
\[ \sin\theta=\frac{\lambda}{Nd} \]
\[ \sin\theta = \frac{500\times10^{-9}} {300(8.33\times10^{-7})} \]
\[ \sin\theta=0.00200 \]
Therefore,
\[ \theta=\sin^{-1}(0.00200) \]
\[ \theta\approx0.00200\text{ rad} \]
Step 4: Calculate the initial screen width.
The screen is \(L=2.0\text{ m}\) from the grating.
Using the small-angle approximation,
\[ x\approx L\theta \]
The displacement from the central maximum to one first minimum is
\[ x=2.0(0.00200) \]
\[ x=0.00400\text{ m} \]
The full width is twice this displacement:
\[ \boxed{\Delta x=8.00\text{ mm}} \]
Step 5: Repeat for the expanded beam.
The new illuminated width is \(0.50\text{ mm}\).
\[ N=1200(0.50) \]
\[ \boxed{N=600} \]
The new first-minimum angle is
\[ \sin\theta = \frac{500\times10^{-9}} {600(8.33\times10^{-7})} \]
\[ \sin\theta=0.00100 \]
Therefore,
\[ \theta\approx0.00100\text{ rad} \]
The full screen width becomes
\[ \Delta x=2L\theta \]
\[ \Delta x=2(2.0)(0.00100) \]
\[ \boxed{\Delta x=4.00\text{ mm}} \]
The expanded beam illuminates twice as many slits. This makes the phase contributions cancel at a smaller angular displacement from the central maximum.
Notice that the grating itself has not changed. It is the number of illuminated slits that has changed.
Question 3
Two diffraction gratings have identical centre-to-centre slit spacings of \(10.0\text{ μm}\).
Grating A has 80 illuminated slits, while Grating B has 160 illuminated slits.
Both are illuminated by the same monochromatic laser.
A student claims that Grating B will produce maxima at twice the angular separation because it has twice as many slits.
Evaluate this claim.
Then explain what happens to the full angular width of the central maximum when changing from Grating A to Grating B.
Solution 3
The student’s claim is incorrect: the principal maxima occur at exactly the same angles, while Grating B produces maxima that are approximately half as wide.
The positions of the principal maxima are determined by
\[ d\sin\theta=m\lambda \]
Neither \(d\) nor \(\lambda\) changes between the two arrangements.
Therefore, the maximum angles remain unchanged.
However, the first-minimum condition is
\[ \sin\theta=\frac{\lambda}{Nd} \]
For Grating A,
\[ \sin\theta_A=\frac{\lambda}{80d} \]
For Grating B,
\[ \sin\theta_B=\frac{\lambda}{160d} \]
Therefore,
\[ \sin\theta_B=\frac{1}{2}\sin\theta_A \]
Since the angles are small in this comparison, the angular distance to the first minimum is approximately halved.
The full angular width of the central maximum is also approximately halved.
The tempting mistake is to assume that adding more slits moves the bright maxima further apart.
It does not. The slit spacing controls their positions. The number of illuminated slits controls how quickly the intensity falls away from those positions.
Question 4
A two-slit arrangement and a ten-slit grating have identical slit spacing and are illuminated by coherent monochromatic light.
Consider an observation direction where the path difference between waves from neighbouring slits is \(0.90\lambda\).
Ignore the single-slit diffraction envelope and compare the interference intensity at this direction with the intensity at a principal maximum.
Calculate the relative intensity for:
a) The two-slit arrangement.
b) The ten-slit grating.
Explain physically why the two arrangements produce such different results.
Solution 4
The two-slit arrangement has approximately \(90.5\%\) of its principal-maximum intensity at this direction, while the ten-slit grating has zero interference intensity.
The difference comes from the way the phase difference accumulates across the slits.
Part a: Two slits
The path difference between neighbouring waves is
\[ \Delta L=0.90\lambda \]
The corresponding phase difference is
\[ \delta=\frac{2\pi\Delta L}{\lambda} \]
Therefore,
\[ \delta=2\pi(0.90) \]
\[ \delta=1.8\pi \]
This is equivalent to a phase difference of \(-36^\circ\), since phases repeat every \(360^\circ\).
For two equal-amplitude waves, the resultant intensity relative to the principal maximum is
\[ \frac{I}{I_{\max}} = \cos^2\left(\frac{\delta}{2}\right) \]
Thus,
\[ \frac{I}{I_{\max}} = \cos^2(18^\circ) \]
\[ \boxed{\frac{I}{I_{\max}}=0.905} \]
The two waves are still nearly in phase, so they reinforce strongly.
Part b: Ten slits
For the ten-slit arrangement, the phase difference between neighbouring contributions is still \(-36^\circ\).
However, there are now ten waves contributing.
Their relative phases are
\[ 0^\circ,-36^\circ,-72^\circ,\ldots,-324^\circ \]
These ten equal-amplitude phasors are evenly distributed around a complete circle.
Their vector sum is zero.
Therefore,
\[ \boxed{I=0} \]
The ten-slit arrangement has a destructive-interference minimum at this direction.
The important difference is that two waves separated by \(36^\circ\) still reinforce strongly. Ten waves separated successively by \(36^\circ\) spread around the complete phase cycle and cancel.
This is why a grating responds much more sharply to a small change in observation angle.
Question 5
Two diffraction gratings are illuminated by coherent monochromatic light over the same effective width of \(1.00\text{ mm}\).
Their properties are:
| Property | Grating A | Grating B |
|---|---|---|
| Slit spacing \(d\) | \(5.00\text{ μm}\) | \(2.50\text{ μm}\) |
| Illuminated slits \(N\) | 200 | 400 |
| Effective illuminated width \(Nd\) | \(1.00\text{ mm}\) | \(1.00\text{ mm}\) |
Both gratings receive light containing two wavelengths:
\[ \lambda_1=500.0\text{ nm} \]
\[ \lambda_2=501.8\text{ nm} \]
Consider the first-order maxima.
For this question, use the following resolution criterion:
Two wavelengths are just resolved when the principal maximum of one wavelength falls at the first minimum immediately beside the principal maximum of the other wavelength.
Assume the single-slit diffraction envelope does not suppress either first-order maximum.
Determine:
a) The angular-coordinate separation between the two first-order maxima for each grating, expressed as a difference in \(\sin\theta\).
b) The distance in \(\sin\theta\) from the first-order maximum of \(\lambda_1\) to its nearest first minimum.
c) Which grating resolves the two wavelengths under the stated criterion.
d) Explain why doubling the number of illuminated slits does not halve the individual peak width in this comparison, even though Grating B resolves the wavelengths more successfully.
Solution 5
Grating A does not resolve the two wavelengths, but Grating B does.
The key is that doubling the number of slits also halves the slit spacing. These two changes affect peak width and wavelength separation differently.
Part a: Calculate the separation between the first-order maxima.
The grating equation is
\[ d\sin\theta=m\lambda \]
For first order, \(m=1\).
Therefore,
\[ \sin\theta=\frac{\lambda}{d} \]
For two wavelengths, the difference in their sine coordinates is
\[ \Delta(\sin\theta)=\frac{\Delta\lambda}{d} \]
The wavelength difference is
\[ \Delta\lambda = 501.8-500.0 \]
\[ \Delta\lambda=1.8\text{ nm} \]
For Grating A,
\[ \Delta(\sin\theta)_A = \frac{1.8\times10^{-9}} {5.00\times10^{-6}} \]
\[ \boxed{\Delta(\sin\theta)_A=0.000360} \]
For Grating B,
\[ \Delta(\sin\theta)_B = \frac{1.8\times10^{-9}} {2.50\times10^{-6}} \]
\[ \boxed{\Delta(\sin\theta)_B=0.000720} \]
Grating B produces twice the separation between the two wavelengths.
Part b: Calculate the distance to the first minimum.
The first minimum beside a principal maximum occurs when the path difference changes by
\[ \frac{\lambda}{N} \]
Therefore, the corresponding change in sine coordinate is
\[ \Delta(\sin\theta)_{\min} = \frac{\lambda}{Nd} \]
For Grating A,
\[ \Delta(\sin\theta)_{\min,A} = \frac{500\times10^{-9}} {200(5.00\times10^{-6})} \]
\[ \boxed{\Delta(\sin\theta)_{\min,A}=0.000500} \]
For Grating B,
\[ \Delta(\sin\theta)_{\min,B} = \frac{500\times10^{-9}} {400(2.50\times10^{-6})} \]
\[ \boxed{\Delta(\sin\theta)_{\min,B}=0.000500} \]
The distance from the principal maximum to its first minimum is identical for both gratings in the sine coordinate.
Part c: Determine which grating resolves the wavelengths.
For Grating A, the separation between the two maxima is
\[ 0.000360 \]
The first-minimum distance is
\[ 0.000500 \]
Since
\[ 0.000360<0.000500 \]
the second wavelength’s maximum lies inside the main peak of the first wavelength.
Grating A does not resolve the two wavelengths.
For Grating B, the separation is
\[ 0.000720 \]
The first-minimum distance remains
\[ 0.000500 \]
Since
\[ 0.000720>0.000500 \]
the second wavelength’s maximum lies beyond the first minimum of the first wavelength.
Grating B resolves the two wavelengths under the stated criterion.
Part d: Explain the difference between peak width and wavelength separation.
This is the important part.
Both gratings have the same effective illuminated width:
\[ Nd=1.00\times10^{-3}\text{ m} \]
Consequently, the first-minimum distance in sine coordinates is the same:
\[ \Delta(\sin\theta)_{\min} = \frac{\lambda}{Nd} \]
Doubling \(N\) does not halve this distance because \(d\) has also halved.
The individual maxima are therefore not twice as narrow in the sine coordinate. In fact, the angular widths are very similar, with a small difference because the first-order angles are different.
However, the separation between two wavelengths is
\[ \Delta(\sin\theta) = \frac{m\Delta\lambda}{d} \]
Halving \(d\) doubles this separation.
That is why Grating B resolves the two wavelengths more successfully even though its individual maxima have not become twice as narrow.
The tempting argument is that more slits must always mean narrower angular peaks.
The missing constraint is that the illuminated physical width has remained fixed. Increasing the line density increases the number of slits, but it also decreases the spacing between them.
This distinction connects peak sharpness to spectral resolution. A grating must produce sufficiently narrow maxima relative to the angular separation of different wavelengths.
07What to remember when answering HSC questions
When comparing two slits with a diffraction grating, separate three different questions.
| What the question asks | What you should consider |
|---|---|
| Where are the principal maxima? | \(d\sin\theta=m\lambda\) |
| How narrow are the principal maxima? | \(N\), the number of illuminated slits |
| What controls the broad diffraction envelope? | \(a\), the individual slit width |
For the first minimum beside the central maximum, remember
\[ d\sin\theta=\frac{\lambda}{N} \]
Increasing \(N\) while keeping \(d\) constant makes the principal maximum narrower.
The deeper idea is that a diffraction grating does not produce a different kind of constructive interference from a double slit. It uses many coherent contributions to make destructive interference develop much more rapidly when the observation direction changes.
Once you understand that, the next useful step is understanding how narrow maxima allow a grating to distinguish two nearby wavelengths. That is the connection to Diffraction Gratings: Spectral Maxima and Resolution.