How to Track Concentration Through Sampling, Dilution and Measurement
Learn how to track solute concentration through sampling, successive dilutions, mixing and instrumental measurement. Includes worked HSC Chemistry examples showing when solute amount is conserved and when reactions must be considered.
A colourimeter reports a concentration of 0.240 g L\(^{-1}\). The original solution was sampled, diluted twice, and then placed in the instrument. Is 0.240 g L\(^{-1}\) the concentration in the original bottle?
No. It is the concentration in the final solution inside the cuvette. To find the original concentration, you must work backwards through every dilution, while keeping track of any solution removed, added, or allowed to react.
The key is to distinguish three different operations:
- Sampling: Removing part of a well-mixed solution changes the amount of solute and the volume remaining, but not the concentration of the remaining solution.
- Dilution: Adding pure solvent increases the volume without changing the amount of solute, provided no reaction or solute loss occurs.
- Mixing: Combining two solutions can add solute from both portions. You must account for the amount contributed by each solution.
Once you know which operation occurred at each stage, tracking concentration becomes a straightforward mass-balance calculation.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
01Understand what sampling actually changes
Imagine a jug of well-mixed cordial. You pour one glass into a separate container.
Has the cordial left in the jug become weaker?
No. You have removed some cordial, but you have removed the water and dissolved cordial concentrate in the same proportion. The remaining mixture has the same concentration.
The same principle applies to a homogeneous chemical solution.
Suppose a solution has:
- Concentration: \(0.200\ \mathrm{mol\,L^{-1}}\)
- Initial volume: \(500.0\ \mathrm{mL}\)
You remove \(50.0\ \mathrm{mL}\) using a pipette.
The remaining solution has a volume of \(450.0\ \mathrm{mL}\), but its concentration is still \(0.200\ \mathrm{mol\,L^{-1}}\).
What has changed is the total amount of solute.
Concentration versus amount of solute
For molar concentration:
\[ c=\frac{n}{V} \]
where:
- \(c\) = concentration in \(\mathrm{mol\,L^{-1}}\)
- \(n\) = amount of solute in mol
- \(V\) = solution volume in L
Rearranging:
\[ n=cV \]
This second equation is particularly useful when tracking samples.
The amount of solute removed in an aliquot is:
\[ n_{\mathrm{sample}}=c_{\mathrm{original}}V_{\mathrm{sample}} \]
The remaining amount is:
\[ n_{\mathrm{remaining}} =c_{\mathrm{original}}(V_{\mathrm{original}}-V_{\mathrm{sample}}) \]
The remaining concentration is still the original concentration, assuming the solution was homogeneous.
| Stage | Volume | Amount of solute | Concentration |
|---|---|---|---|
| Original solution | \(V_0\) | \(c_0V_0\) | \(c_0\) |
| Sample removed | \(V_s\) | \(c_0V_s\) in sample | \(c_0\) |
| Remaining stock | \(V_0-V_s\) | \(c_0(V_0-V_s)\) | \(c_0\) |
| Sample after dilution | \(V_f\) | \(c_0V_s\) | \(c_0V_s/V_f\) |
Notice that the sample and the remaining stock initially have the same concentration.
Their amounts of solute are different because their volumes are different.
Important limitation: This reasoning assumes the original solution is homogeneous. If solids have settled, different layers have formed, or the sample is not representative, the withdrawn portion may have a different composition from the bulk solution.
02Track a single-solution dilution
Now consider what happens when you take that sample and add pure water.
This time, the concentration really does change.
The amount of solute in the sample remains constant, but its volume increases.
For a dilution with no chemical reaction or solute loss:
\[ n_{\mathrm{before}}=n_{\mathrm{after}} \]
Using \(n=cV\):
\[ c_1V_1=c_2V_2 \]
where:
- \(c_1\) = concentration before dilution
- \(V_1\) = volume of the aliquot taken
- \(c_2\) = concentration after dilution
- \(V_2\) = final volume after adding solvent
The most important detail is that \(V_2\) is the final volume, not the volume of water added.
For example, if you transfer \(20.0\ \mathrm{mL}\) of solution into a volumetric flask and make it up to \(100.0\ \mathrm{mL}\), then:
\[ V_1=20.0\ \mathrm{mL} \]
\[ V_2=100.0\ \mathrm{mL} \]
You do not use \(80.0\ \mathrm{mL}\) as the final volume.
The dilution equation becomes:
\[ c_2=c_1\frac{V_1}{V_2} \]
The concentration decreases because the original amount of solute is now distributed through a larger volume.
Understanding the dilution factor
The dilution factor tells you how many times the original solution has been diluted.
\[ DF=\frac{V_{\mathrm{final}}}{V_{\mathrm{aliquot}}} \]
For the \(20.0\ \mathrm{mL}\) to \(100.0\ \mathrm{mL}\) dilution:
\[ DF=\frac{100.0}{20.0}=5.00 \]
The final concentration is one-fifth of the original sample concentration.
If you know the diluted concentration and want to recover the original concentration:
\[ c_{\mathrm{original}}=c_{\mathrm{diluted}}\times DF \]
This is the basic principle behind working backwards from an instrument reading.
What happens during successive dilutions?
Sometimes a sample is diluted more than once before it is measured.
For example:
- Take \(10.0\ \mathrm{mL}\) of the original sample and dilute it to \(100.0\ \mathrm{mL}\).
- Take \(20.0\ \mathrm{mL}\) of that diluted solution and dilute it to \(50.0\ \mathrm{mL}\).
The first dilution factor is:
\[ DF_1=\frac{100.0}{10.0}=10.0 \]
The second dilution factor is:
\[ DF_2=\frac{50.0}{20.0}=2.50 \]
The total dilution factor is the product:
\[ DF_{\mathrm{total}}=DF_1\times DF_2 \]
\[ DF_{\mathrm{total}}=10.0\times2.50=25.0 \]
Therefore:
\[ c_{\mathrm{original}}=25.0c_{\mathrm{final}} \]
You multiply the dilution factors because each dilution acts on the solution produced by the previous dilution.
For more practice with this particular calculation, see How to Calculate a Serial-Dilution Factor in HSC Chemistry.
03Mixing two solutions is different from dilution
This is where a common mistake appears.
Suppose you have two solutions containing the same dissolved substance. You pour them together.
Can you use \(c_1V_1=c_2V_2\)?
Not by itself.
That equation assumes the amount of solute remains unchanged during a single-solution dilution. But when you mix two solutions containing the same solute, both solutions contribute solute.
You must add their amounts first.
For two solutions containing the same non-reacting solute:
\[ n_{\mathrm{total}}=n_1+n_2 \]
Therefore:
\[ c_fV_f=c_1V_1+c_2V_2 \]
Rearranging:
\[ \boxed{ c_f=\frac{c_1V_1+c_2V_2}{V_f} } \]
Here, \(V_f\) is the final mixture volume. If the question assumes volumes are additive, then \(V_f=V_1+V_2\).
A useful comparison
Consider two different operations involving glucose.
| Operation | Initial solutions | Final concentration |
|---|---|---|
| Dilution | \(50.0\ \mathrm{mL}\) of \(0.100\ \mathrm{M}\) glucose plus \(50.0\ \mathrm{mL}\) water | \(0.0500\ \mathrm{M}\) |
| Mixing | \(50.0\ \mathrm{mL}\) of \(0.100\ \mathrm{M}\) glucose plus \(50.0\ \mathrm{mL}\) of \(0.100\ \mathrm{M}\) glucose | \(0.100\ \mathrm{M}\) |
In the first situation, the water contributes no glucose.
In the second, the additional solution contributes an equal amount of glucose to the mixture. Doubling the volume also doubles the amount of glucose, so the concentration stays unchanged.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
The distinction is simple:
- Pure solvent adds volume but no solute.
- Another solution adds both volume and its own amount of solute.
If the solutions contain different solutes, calculate the amount of each solute separately.
If a chemical reaction occurs, you must first determine how much of each reacting substance is consumed. You cannot assume the original amount of each chemical species is conserved.
We will examine that situation later.
04Follow the concentration through an actual measurement
So far, we have tracked what happens to the solution before it reaches an instrument.
But what exactly does the instrument measure?
Consider an investigation where a chemist wants to determine the concentration of a coloured substance in an unknown solution.
A colourimeter can measure how much light is absorbed by the sample. However, it does not automatically know the concentration in the original stock bottle.
It measures the prepared solution placed inside its cuvette.
How the experimental setup works
The process follows a particular sequence.
Step 1: Prepare known standard solutions.
Prepare several solutions with known concentrations of the coloured substance.
These standards provide a reference for interpreting the unknown sample.
Step 2: Establish the instrument baseline.
Place a blank solution in the colourimeter. This usually contains the solvent and any other reagents, but not the analyte being measured.
The blank helps account for light absorbed by the solvent, cuvette, and other components.
Step 3: Measure the standards.
Light passes through each cuvette to a detector.
The colourimeter measures the transmitted light and calculates the absorbance.
Step 4: Construct a calibration curve.
Plot absorbance against the known concentrations of the standards.
This produces a relationship that can be used to estimate the concentration of an unknown sample.
Step 5: Prepare and measure the unknown.
Take a known aliquot from the original solution, dilute it if necessary, and transfer some of the prepared solution into a cuvette.
Measure its absorbance and use the calibration curve to determine the concentration inside the cuvette.
Step 6: Calculate the original concentration.
Multiply the measured concentration by the total dilution factor.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Reading a calibration curve
Consider the following illustrative calibration data.
| Standard concentration (mmol L\(^{-1}\)) | Absorbance |
|---|---|
| 0.00 | 0.000 |
| 2.00 | 0.250 |
| 4.00 | 0.500 |
| 6.00 | 0.750 |
| 8.00 | 1.000 |
These illustrative readings produce a linear calibration relationship:
\[ A=0.125c \]
where:
- \(A\) = absorbance, which is dimensionless
- \(c\) = concentration in \(\mathrm{mmol\,L^{-1}}\)
Suppose an unknown diluted sample has an absorbance of \(0.300\).
Rearrange the calibration equation:
\[ c=\frac{A}{0.125} \]
\[ c=\frac{0.300}{0.125} \]
\[ c=2.40\ \mathrm{mmol\,L^{-1}} \]
This is the concentration of the solution in the cuvette.
It is not necessarily the concentration in the original stock.
- Best-fit line: A = 0.125c
- Illustrative standards
- Unknown absorbance: A = 0.300
- 2.40 mmol L⁻¹
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
What if the original solution is too concentrated?
This is an important experimental limitation.
Imagine measuring the original stock solution directly. Its absorbance might be higher than the highest standard used to construct the calibration curve.
You might be tempted to extend the straight line beyond the measured standards and estimate the concentration.
That is not necessarily reliable. The calibration relationship may no longer be linear outside the tested range.
A better approach is to dilute a measured aliquot of the original solution and repeat the measurement.
This revised procedure has two advantages:
- The instrument reading can fall within the calibration range.
- The original concentration can still be calculated because the dilution factor is known.
The dilution factor is therefore not just a mathematical convenience. It is essential experimental information.
If you do not record the aliquot volume and final dilution volume, you may not be able to reconstruct the original concentration.
Also remember that a calibration curve assumes the sample behaves sufficiently like the standards. Other absorbing substances, turbidity, or chemical changes can interfere with the measurement.
05A reliable method for tracking concentration
When you encounter a question involving sampling, dilution, mixing, and measurement, work through the following decisions in order.
First: Identify the original solution.
Record its initial concentration and volume if they are known.
Second: Identify every sampling step.
For a homogeneous solution, the concentration of the withdrawn aliquot is the same as the concentration of the original solution at that time.
If the aliquot is removed and discarded, the remaining stock has less solute and less volume, but its concentration is unchanged.
Third: Identify every dilution.
For each dilution, record:
\[ DF=\frac{V_{\mathrm{final}}}{V_{\mathrm{aliquot}}} \]
Do not confuse the final volume with the volume of solvent added.
Fourth: Check whether another solution was mixed in.
If another solution contains the same non-reacting solute, calculate the amount contributed by both portions.
Do not treat an additional solute-containing solution as pure water.
Fifth: Check for chemical reactions.
If a reaction occurs, calculate the amount of each species remaining using the balanced equation and mole ratios.
Only then calculate the final concentration.
Sixth: Interpret the measurement correctly.
An instrument reading or calibration result normally describes the solution actually measured.
Reverse the dilution steps to find the concentration before sample preparation.
A useful summary is:
| What happened? | What should you calculate? |
|---|---|
| A sample was removed from a homogeneous solution | Remaining stock concentration stays the same |
| Pure solvent was added to an aliquot | Conserve solute amount and calculate the new concentration |
| Two solutions containing the same solute were mixed | Add the amounts of solute from both solutions |
| Different solutes were mixed without reacting | Track each solute separately |
| A chemical reaction occurred | Use stoichiometry before calculating concentration |
| A diluted sample was measured | Convert the instrument result back using the total dilution factor |
06Worked examples
Worked example: Sampling a stock solution and preparing a dilution
A bottle contains \(250.0\ \mathrm{mL}\) of sodium chloride solution with a concentration of \(0.120\ \mathrm{mol\,L^{-1}}\).
A student removes a \(20.0\ \mathrm{mL}\) aliquot using a pipette and dilutes it to a final volume of \(100.0\ \mathrm{mL}\).
Calculate:
(a) The concentration of the diluted solution.
(b) The amount of sodium chloride in the aliquot.
(c) The concentration and amount of sodium chloride remaining in the original bottle.
Assume the original solution is homogeneous and no solute is lost or reacts.
Step 1
The original solution is homogeneous, so the aliquot has the same concentration:
\[ c_{\mathrm{sample}}=0.120\ \mathrm{mol\,L^{-1}} \]
Step 2
Use:
\[ n=cV \]
Convert the sample volume to litres:
\[ V=20.0\ \mathrm{mL}=0.0200\ \mathrm{L} \]
Substitute:
\[ n=0.120\times0.0200 \]
\[ \boxed{n=0.00240\ \mathrm{mol}} \]
This is the amount of sodium chloride transferred into the volumetric flask.
Step 3
The amount of sodium chloride remains \(0.00240\ \mathrm{mol}\), but the final volume is now \(0.1000\ \mathrm{L}\).
Therefore:
\[ c=\frac{n}{V} \]
\[ c=\frac{0.00240}{0.1000} \]
\[ \boxed{c=0.0240\ \mathrm{mol\,L^{-1}}} \]
The diluted solution has one-fifth the concentration of the original stock.
Step 4
The volume remaining is:
\[ V_{\mathrm{remaining}}=250.0-20.0 \]
\[ V_{\mathrm{remaining}}=230.0\ \mathrm{mL} \]
Convert to litres:
\[ V_{\mathrm{remaining}}=0.2300\ \mathrm{L} \]
Now calculate the remaining amount:
\[ n_{\mathrm{remaining}}=cV \]
\[ n_{\mathrm{remaining}}=0.120\times0.2300 \]
\[ \boxed{n_{\mathrm{remaining}}=0.0276\ \mathrm{mol}} \]
The concentration is still:
\[ \boxed{c_{\mathrm{remaining}}=0.120\ \mathrm{mol\,L^{-1}}} \]
The stock bottle has less solution and less sodium chloride, but its concentration has not changed.
This is the key difference between removing a sample and diluting a sample.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Worked example: Finding the original concentration from a measurement
An unknown solution undergoes two successive dilutions before being analysed using a colourimeter.
The preparation procedure is:
- \(10.00\ \mathrm{mL}\) of the original solution is diluted to \(100.0\ \mathrm{mL}\).
- \(20.00\ \mathrm{mL}\) of the first diluted solution is then diluted to \(50.00\ \mathrm{mL}\).
The final solution has an absorbance of \(0.300\).
An illustrative calibration equation is:
\[ A=0.125c \]
where \(c\) is measured in \(\mathrm{mmol\,L^{-1}}\).
Calculate the concentration of the original solution.
Assume the calibration is linear over the relevant range and the absorbance has been corrected using a blank.
Step 1
We know:
\[ A=0.300 \]
\[ A=0.125c \]
Rearrange:
\[ c=\frac{A}{0.125} \]
Substitute:
\[ c=\frac{0.300}{0.125} \]
\[ \boxed{c_{\mathrm{measured}}=2.40\ \mathrm{mmol\,L^{-1}}} \]
This is the concentration in the colourimeter cuvette.
Step 2
The second dilution used \(20.00\ \mathrm{mL}\) and produced a final volume of \(50.00\ \mathrm{mL}\).
Its dilution factor is:
\[ DF_2=\frac{50.00}{20.00}=2.50 \]
Therefore, the concentration before the second dilution was:
\[ c_1=2.40\times2.50 \]
\[ c_1=6.00\ \mathrm{mmol\,L^{-1}} \]
Step 3
The first dilution used \(10.00\ \mathrm{mL}\) and produced a final volume of \(100.0\ \mathrm{mL}\).
Its dilution factor is:
\[ DF_1=\frac{100.0}{10.00}=10.0 \]
Therefore:
\[ c_{\mathrm{original}}=6.00\times10.0 \]
\[ \boxed{c_{\mathrm{original}}=60.0\ \mathrm{mmol\,L^{-1}}} \]
Converting to molar concentration:
\[ \boxed{c_{\mathrm{original}}=0.0600\ \mathrm{mol\,L^{-1}}} \]
Step 4
The total dilution factor is:
\[ DF_{\mathrm{total}}=2.50\times10.0=25.0 \]
Therefore:
\[ c_{\mathrm{original}}=2.40\times25.0 \]
\[ =60.0\ \mathrm{mmol\,L^{-1}} \]
Both methods give the same result.
The important point is that the colourimeter measured the final prepared solution. You had to reverse both dilution steps to recover the concentration of the original sample.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
07Questions and solutions
Question 1
An aqueous sodium chloride solution has a concentration of \(0.0800\ \mathrm{mol\,L^{-1}}\).
A student transfers \(15.0\ \mathrm{mL}\) of this solution into a volumetric flask and adds deionised water until the final volume reaches \(150.0\ \mathrm{mL}\).
Calculate:
(a) The concentration of the diluted solution.
(b) The amount of sodium chloride in the diluted solution.
Assume no reaction or solute loss.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 1
The diluted concentration is \(0.00800\ \mathrm{mol\,L^{-1}}\), and the amount of sodium chloride is \(1.20\times10^{-3}\ \mathrm{mol}\).
(a) Calculate the diluted concentration.
Use the dilution equation:
\[ c_1V_1=c_2V_2 \]
Rearrange:
\[ c_2=\frac{c_1V_1}{V_2} \]
Substitute:
\[ c_2=\frac{0.0800\times15.0}{150.0} \]
\[ \boxed{c_2=0.00800\ \mathrm{mol\,L^{-1}}} \]
The concentration decreases by a factor of 10 because the original aliquot has been diluted to ten times its initial volume.
(b) Calculate the amount of sodium chloride.
The amount of solute is unchanged during dilution.
\[ n=cV \]
Convert the aliquot volume into litres:
\[ V=0.0150\ \mathrm{L} \]
Therefore:
\[ n=0.0800\times0.0150 \]
\[ \boxed{n=1.20\times10^{-3}\ \mathrm{mol}} \]
We can check this using the final solution:
\[ n=0.00800\times0.1500 \]
\[ n=1.20\times10^{-3}\ \mathrm{mol} \]
Both calculations agree.
Question 2
An unknown solution is prepared for instrumental analysis using the following procedure:
- A \(5.00\ \mathrm{mL}\) aliquot of the original solution is diluted to \(50.0\ \mathrm{mL}\).
- A \(10.0\ \mathrm{mL}\) aliquot of this first dilution is transferred into another volumetric flask and diluted to \(25.0\ \mathrm{mL}\).
- A calibration curve indicates that the concentration in the final cuvette is \(0.240\ \mathrm{g\,L^{-1}}\).
Calculate the original mass concentration of the unknown solution.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 2
The original mass concentration is \(6.00\ \mathrm{g\,L^{-1}}\).
The final measured concentration is lower than the original concentration because the sample has been diluted twice.
We need to reverse both dilution steps.
Step 1: Calculate the first dilution factor.
\[ DF_1=\frac{50.0}{5.00} \]
\[ DF_1=10.0 \]
Step 2: Calculate the second dilution factor.
\[ DF_2=\frac{25.0}{10.0} \]
\[ DF_2=2.50 \]
Step 3: Calculate the total dilution factor.
\[ DF_{\mathrm{total}}=10.0\times2.50 \]
\[ DF_{\mathrm{total}}=25.0 \]
Step 4: Calculate the original concentration.
The instrument measured:
\[ c_{\mathrm{final}}=0.240\ \mathrm{g\,L^{-1}} \]
Therefore:
\[ c_{\mathrm{original}}=c_{\mathrm{final}}\times DF_{\mathrm{total}} \]
\[ c_{\mathrm{original}}=0.240\times25.0 \]
\[ \boxed{c_{\mathrm{original}}=6.00\ \mathrm{g\,L^{-1}}} \]
The result is the mass concentration before either dilution occurred.
A common mistake is to reverse only the last dilution. That would give \(0.600\ \mathrm{g\,L^{-1}}\), which is the concentration before the second dilution, not the original concentration.
Question 3
A student combines two glucose solutions in a flask.
- Solution A: \(40.0\ \mathrm{mL}\) of \(0.150\ \mathrm{mol\,L^{-1}}\) glucose.
- Solution B: \(60.0\ \mathrm{mL}\) of \(0.0500\ \mathrm{mol\,L^{-1}}\) glucose.
Assume the solutions do not react and their volumes are additive.
Calculate the final glucose concentration.
A student argues that the original solution has simply been diluted from \(40.0\ \mathrm{mL}\) to \(100.0\ \mathrm{mL}\), so the final concentration must be \(0.0600\ \mathrm{mol\,L^{-1}}\).
Explain why this reasoning is incorrect.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 3
The final glucose concentration is \(0.0900\ \mathrm{mol\,L^{-1}}\), not \(0.0600\ \mathrm{mol\,L^{-1}}\).
The incorrect calculation treats Solution B as though it were pure water.
However, Solution B also contains glucose, so its solute amount must be included.
Step 1: Calculate the amount of glucose in Solution A.
Convert the volume:
\[ V_A=0.0400\ \mathrm{L} \]
Then:
\[ n_A=c_AV_A \]
\[ n_A=0.150\times0.0400 \]
\[ n_A=0.00600\ \mathrm{mol} \]
Step 2: Calculate the amount of glucose in Solution B.
\[ V_B=0.0600\ \mathrm{L} \]
\[ n_B=c_BV_B \]
\[ n_B=0.0500\times0.0600 \]
\[ n_B=0.00300\ \mathrm{mol} \]
Step 3: Add the amounts of glucose.
Because the solutions do not react:
\[ n_{\mathrm{total}}=n_A+n_B \]
\[ n_{\mathrm{total}}=0.00600+0.00300 \]
\[ n_{\mathrm{total}}=0.00900\ \mathrm{mol} \]
Step 4: Calculate the final concentration.
The total volume is:
\[ V_f=0.0400+0.0600 \]
\[ V_f=0.1000\ \mathrm{L} \]
Therefore:
\[ c_f=\frac{n_{\mathrm{total}}}{V_f} \]
\[ c_f=\frac{0.00900}{0.1000} \]
\[ \boxed{c_f=0.0900\ \mathrm{mol\,L^{-1}}} \]
The tempting calculation gives:
\[ c_f=\frac{0.150\times0.0400}{0.1000} \]
\[ =0.0600\ \mathrm{mol\,L^{-1}} \]
This result ignores the glucose contributed by Solution B.
The distinction is that adding pure water conserves the solute amount already present, whereas mixing two glucose solutions combines their solute amounts.
Question 4
A student mixes the following two solutions:
- \(25.0\ \mathrm{mL}\) of \(0.100\ \mathrm{mol\,L^{-1}}\) hydrochloric acid.
- \(40.0\ \mathrm{mL}\) of \(0.0500\ \mathrm{mol\,L^{-1}}\) sodium hydroxide.
The reaction proceeds to completion.
Assume both substances dissociate completely, the final volume is additive, and the contribution of water autoionisation is negligible.
Calculate:
(a) The final hydrogen ion concentration, \([\mathrm{H^+}]\).
(b) The final chloride ion concentration, \([\mathrm{Cl^-}]\).
(c) The final sodium ion concentration, \([\mathrm{Na^+}]\).
Explain why applying a simple dilution equation to the original hydrochloric acid concentration gives an incorrect answer for \([\mathrm{H^+}]\).
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 4
The final concentrations are \([\mathrm{H^+}]=0.00769\ \mathrm{mol\,L^{-1}}\), \([\mathrm{Cl^-}]=0.0385\ \mathrm{mol\,L^{-1}}\), and \([\mathrm{Na^+}]=0.0308\ \mathrm{mol\,L^{-1}}\).
The important difference from the previous question is that these solutions react.
Hydrochloric acid and sodium hydroxide neutralise each other:
\[ \ce{H+ + OH- -> H2O} \]
We must calculate the reacting amounts before finding the final concentrations.
Step 1: Calculate the initial amount of hydrogen ions.
Hydrochloric acid is a strong acid and dissociates completely.
\[ n(\mathrm{H}^{+})=cV \]
\[ n(\mathrm{H}^{+})=0.100\times0.0250 \]
\[ n(\mathrm{H}^{+})=2.50\times10^{-3}\ \mathrm{mol} \]
Step 2: Calculate the initial amount of hydroxide ions.
Sodium hydroxide also dissociates completely.
\[ n(\ce{OH-})=0.0500\times0.0400 \]
\[ n(\ce{OH-})=2.00\times10^{-3}\ \mathrm{mol} \]
Step 3: Determine which reactant is in excess.
The reaction has a 1:1 mole ratio.
Therefore, the excess hydrogen ion amount is:
\[ n_{\mathrm{excess}}(\mathrm{H}^{+}) =2.50\times10^{-3} -2.00\times10^{-3} \]
\[ =5.00\times10^{-4}\ \mathrm{mol} \]
Hydrogen ions remain in excess.
Step 4: Calculate the final hydrogen ion concentration.
The final volume is:
\[ V_f=25.0+40.0 \]
\[ V_f=65.0\ \mathrm{mL} \]
\[ V_f=0.0650\ \mathrm{L} \]
Therefore:
\[ [\mathrm{H}^{+}] =\frac{5.00\times10^{-4}}{0.0650} \]
\[ \boxed{[\mathrm{H}^{+}]=0.00769\ \mathrm{mol\,L^{-1}}} \]
Step 5: Calculate the chloride ion concentration.
Chloride ions do not participate in the neutralisation reaction.
Their original amount is conserved:
\[ n(\mathrm{Cl}^{-})=2.50\times10^{-3}\ \mathrm{mol} \]
Therefore:
\[ [\mathrm{Cl}^{-}] =\frac{2.50\times10^{-3}}{0.0650} \]
\[ \boxed{[\mathrm{Cl}^{-}]=0.0385\ \mathrm{mol\,L^{-1}}} \]
Step 6: Calculate the sodium ion concentration.
Sodium ions are also spectator ions.
Their original amount is:
\[ n(\mathrm{Na}^{+})=2.00\times10^{-3}\ \mathrm{mol} \]
Therefore:
\[ [\mathrm{Na}^{+}] =\frac{2.00\times10^{-3}}{0.0650} \]
\[ \boxed{[\mathrm{Na}^{+}]=0.0308\ \mathrm{mol\,L^{-1}}} \]
Step 7: Check the result using charge balance.
The positive ion concentrations should balance the negative ion concentrations.
Using our calculated values:
\[ [\mathrm{H}^{+}]+[\mathrm{Na}^{+}] \approx[\mathrm{Cl}^{-}] \]
\[ 0.00769+0.0308\approx0.0385 \]
The values agree within rounding.
This also explains the student’s mistake.
If you simply diluted the original hydrochloric acid to the final volume, you would calculate:
\[ \frac{0.100\times25.0}{65.0} =0.0385\ \mathrm{mol\,L^{-1}} \]
That value is actually the final chloride ion concentration.
It is not the final hydrogen ion concentration because some hydrogen ions were consumed during neutralisation.
This is a crucial distinction: the amount of chloride ions is conserved, but the amount of hydrogen ions is not.
Question 5
A well-mixed stock solution contains an unknown concentration of a non-reacting solute \(S\).
The original stock volume is \(500.0\ \mathrm{mL}\).
A technician performs the following procedure.
Stage 1: First sample
A \(50.0\ \mathrm{mL}\) sample is removed from the original stock and diluted to \(250.0\ \mathrm{mL}\).
The instrument measures its concentration as \(0.150\ \mathrm{g\,L^{-1}}\).
The sample is not returned to the original stock.
Stage 2: Replacing part of the stock with water
From the remaining stock, the technician removes \(100.0\ \mathrm{mL}\) and discards it.
The technician then adds exactly \(100.0\ \mathrm{mL}\) of pure water and mixes thoroughly.
Stage 3: Second sample
A \(20.0\ \mathrm{mL}\) aliquot of this new mixture is removed and diluted to \(100.0\ \mathrm{mL}\).
The instrument reports a concentration of \(0.1167\ \mathrm{g\,L^{-1}}\).
Determine:
(a) The original stock concentration.
(b) The amount of solute remaining after Stage 2.
(c) The concentration of the stock after Stage 2.
(d) Whether the second instrument reading is consistent with the first reading.
A student argues that the concentration after Stage 2 should be \(0.600\ \mathrm{g\,L^{-1}}\), because removing \(100.0\ \mathrm{mL}\) from a \(500.0\ \mathrm{mL}\) solution and replacing it with water leaves 80% of the original concentration.
Explain exactly why this argument is incorrect.
Assume both samples are representative, no solute reacts or is lost, and all stated volumes are accurate.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 5
The original concentration is \(0.750\ \mathrm{g\,L^{-1}}\), the amount remaining after Stage 2 is \(0.2625\ \mathrm{g}\), and the new stock concentration is approximately \(0.5833\ \mathrm{g\,L^{-1}}\). The second measurement is consistent with the first.
The student’s \(0.600\ \mathrm{g\,L^{-1}}\) result is incorrect because it assumes the stock still contains \(500.0\ \mathrm{mL}\) immediately before the second removal.
It does not.
The first \(50.0\ \mathrm{mL}\) sample was already removed and never returned.
We need to track the actual volume and amount of solute at each stage.
Step 1: Calculate the original concentration using the first measurement.
The first aliquot was diluted from \(50.0\ \mathrm{mL}\) to \(250.0\ \mathrm{mL}\).
Its dilution factor is:
\[ DF_1=\frac{250.0}{50.0}=5.00 \]
The measured concentration was:
\[ c_{\mathrm{measured}}=0.150\ \mathrm{g\,L^{-1}} \]
Therefore:
\[ c_0=0.150\times5.00 \]
\[ \boxed{c_0=0.750\ \mathrm{g\,L^{-1}}} \]
This is the concentration of the original stock.
Step 2: Account for the first sample removal.
The original stock volume was:
\[ V_0=500.0\ \mathrm{mL} \]
After removing \(50.0\ \mathrm{mL}\):
\[ V_{\mathrm{remaining}}=500.0-50.0 \]
\[ \boxed{V_{\mathrm{remaining}}=450.0\ \mathrm{mL}} \]
The concentration of the remaining stock is still:
\[ 0.750\ \mathrm{g\,L^{-1}} \]
This is because the first operation was sampling, not dilution.
Step 3: Calculate the amount of solute before the second removal.
Convert the remaining volume into litres:
\[ V=0.4500\ \mathrm{L} \]
Use:
\[ m=c_mV \]
where \(c_m\) is mass concentration and \(m\) is the mass of solute.
\[ m=0.750\times0.4500 \]
\[ m=0.3375\ \mathrm{g} \]
The stock therefore contains \(0.3375\ \mathrm{g}\) of solute immediately before Stage 2.
Step 4: Calculate the amount removed in the second operation.
The technician removes \(100.0\ \mathrm{mL}\) from a \(450.0\ \mathrm{mL}\) solution.
The concentration is still \(0.750\ \mathrm{g\,L^{-1}}\) before removal.
Convert the removed volume:
\[ V_{\mathrm{removed}}=0.1000\ \mathrm{L} \]
Calculate the amount removed:
\[ m_{\mathrm{removed}}=0.750\times0.1000 \]
\[ m_{\mathrm{removed}}=0.0750\ \mathrm{g} \]
Therefore, the amount of solute left is:
\[ m_{\mathrm{left}}=0.3375-0.0750 \]
\[ \boxed{m_{\mathrm{left}}=0.2625\ \mathrm{g}} \]
Step 5: Account for the water added.
The stock initially contained \(450.0\ \mathrm{mL}\) after the first sampling.
Removing \(100.0\ \mathrm{mL}\) leaves:
\[ 450.0-100.0=350.0\ \mathrm{mL} \]
Adding \(100.0\ \mathrm{mL}\) of water restores the volume to:
\[ V_f=350.0+100.0 \]
\[ V_f=450.0\ \mathrm{mL} \]
The amount of solute remains \(0.2625\ \mathrm{g}\), because the added water contains no solute and no reaction occurs.
Step 6: Calculate the new stock concentration.
Convert the final volume:
\[ V_f=0.4500\ \mathrm{L} \]
Then:
\[ c_f=\frac{m_{\mathrm{left}}}{V_f} \]
\[ c_f=\frac{0.2625}{0.4500} \]
\[ \boxed{c_f=0.5833\ \mathrm{g\,L^{-1}}} \]
The concentration has decreased because some of the original solute was discarded and replaced with pure water.
Step 7: Check the second instrument reading.
The second sample was diluted from \(20.0\ \mathrm{mL}\) to \(100.0\ \mathrm{mL}\).
Its dilution factor is:
\[ DF_2=\frac{100.0}{20.0}=5.00 \]
Therefore, the expected concentration in the final cuvette is:
\[ c_{\mathrm{expected}} =\frac{0.5833}{5.00} \]
\[ \boxed{c_{\mathrm{expected}}\approx0.1167\ \mathrm{g\,L^{-1}}} \]
The instrument reported:
\[ c_{\mathrm{measured}}=0.1167\ \mathrm{g\,L^{-1}} \]
The readings agree within the stated precision.
Step 8: Identify the exact error in the student’s calculation.
The student used:
\[ c_f=0.750\times\frac{400}{500} \]
\[ c_f=0.600\ \mathrm{g\,L^{-1}} \]
This calculation assumes that \(100.0\ \mathrm{mL}\) was removed from the original \(500.0\ \mathrm{mL}\) stock.
But that is not what happened.
The first \(50.0\ \mathrm{mL}\) had already been removed, leaving \(450.0\ \mathrm{mL}\).
The correct fraction of solute remaining after the second removal is:
\[ \frac{350.0}{450.0}=\frac{7}{9} \]
Therefore:
\[ c_f=0.750\times\frac{350.0}{450.0} \]
\[ \boxed{c_f=0.5833\ \mathrm{g\,L^{-1}}} \]
The difference comes from tracking the actual state of the stock solution rather than repeatedly assuming the original volume.
This question brings together the central ideas of concentration tracking:
- The first sampling changes the stock volume and amount, but not its concentration.
- The second removal also leaves the concentration unchanged until water is added.
- Adding water reduces the concentration because the amount of solute stays constant while the volume increases.
- The second instrument reading describes the final diluted aliquot, not the stock solution.
08What to carry into your next chemistry calculation
Whenever a concentration question involves more than one stage, resist the temptation to apply \(c_1V_1=c_2V_2\) automatically.
First ask what physically happened to the solution.
Was some of it removed? Was pure water added? Was another solution mixed in? Did a reaction occur?
These questions determine whether you should conserve the amount of solute, add contributions from multiple solutions, or use stoichiometry to calculate what remains.
Once you can distinguish these situations, even complicated sequences of sampling and measurement become manageable.
For further practice, continue with How to Perform a Solution Dilution in HSC Chemistry for the practical preparation method, or How to Find Concentration After Mixing Two Solutions for more involved mixture calculations.