Why Closer Electric Field Lines Mean a Stronger Field
Understand why closer electric field lines indicate a stronger electric field by exploring field-line density, point charges, and uniform fields. Includes worked HSC Physics examples and practice questions covering field strength, force, and superposition.
A field-line diagram shows a positive charge surrounded by 12 radial lines. All 12 lines cross a spherical surface close to the charge. Further out, the same 12 lines cross a much larger spherical surface.
If the number of lines hasn’t changed, why has the electric field become weaker?
The answer is field-line density. The further surface has more area for the same lines to spread across, so fewer lines pass through each square metre. Closer field lines indicate a stronger electric field because they represent a greater number of field lines per unit area perpendicular to the field.
This is a visual representation of something physical: the electric field strength at a location.
01What does electric field strength actually measure?
Before interpreting field-line spacing, you need to understand what the electric field describes.
Imagine placing a small positive charge near another charged object. The two charges exert an electric force on each other.
Now imagine replacing that small charge with one twice as large.
The electric force doubles, but has the electric field itself become stronger?
No. The field has not changed. You have simply placed a larger charge in the same field.
This is why physicists define electric field strength as the electric force per unit positive test charge:
\[ \vec E=\frac{\vec F}{q} \]
Where:
- \(\vec E\) is electric field strength, measured in newtons per coulomb (\(\text{N C}^{-1}\)).
- \(\vec F\) is the electric force on the test charge, measured in newtons (N).
- \(q\) is the positive test charge, measured in coulombs (C).
The electric field is created by the source charges. It exists whether or not you place a test charge there.
A test charge is simply a way to investigate the field. We assume it is sufficiently small that it does not significantly disturb the original arrangement of source charges.
A quick example
Suppose the electric field at a particular location is \(500\text{ N C}^{-1}\), directed towards the right.
Place a positive \(2.0\,\mu\text{C}\) test charge there.
Its force is:
\[ F=qE \]
\[ F=(2.0\times10^{-6})(500) \]
\[ F=1.0\times10^{-3}\text{ N} \]
Now replace it with a positive \(4.0\,\mu\text{C}\) charge.
The force becomes \(2.0\times10^{-3}\text{ N}\), but the electric field remains \(500\text{ N C}^{-1}\).
The important distinction is:
- Electric field strength describes the electrical conditions at a location.
- Electric force describes how a particular charge responds to those conditions.
A negative test charge experiences a force in the opposite direction to the electric field.
02Why does field-line density indicate field strength?
Now that we know what the electric field measures, we can understand the purpose of field lines.
Electric field lines are imaginary lines used to represent an electric field. They communicate two different pieces of information:
- Their arrows show the direction of the electric field.
- Their spacing shows the relative strength of the electric field.
The second point is the one we are interested in.
Understanding field-line density
Imagine drawing a small imaginary surface perpendicular to the electric field.
Count how many field lines pass through it.
If many lines pass through a small area, the field-line density is high. If fewer lines pass through the same area, the density is low.
The relationship is:
\[ E\propto\frac{\Delta L}{\Delta A_\perp} \]
Where:
- \(E\) is electric field strength.
- \(\Delta L\) is the number of drawn field lines crossing the surface.
- \(\Delta A_\perp\) is the area perpendicular to the field.
The number of lines is a drawing convention, not a physical quantity with its own SI unit. However, provided the same drawing convention is used, a greater line density represents a stronger electric field.
Think of a crowd leaving a stadium and spreading into a large open area.
Near the stadium exit, people are packed closely together. Further away, the same crowd spreads across a much larger area.
The number of people has not disappeared. Their density has decreased.
Electric field lines behave similarly in the diagram. The same total collection of lines can spread across a larger area, reducing the number passing through each unit of area.
There is one important limitation to this analogy: people are physical objects, whereas electric field lines are mathematical representations. They do not travel through space as actual threads.
Why the spacing matters
Consider two regions of an electric field diagram.
- Region A has 10 lines crossing each square centimetre.
- Region B has 5 lines crossing each square centimetre.
Using the same drawing convention, the electric field at A is twice as strong as the electric field at B.
Notice that we are comparing the number of lines per unit area, not simply counting all the lines in the picture.
This distinction becomes particularly important when comparing different charged objects.
03The experiment that established the relationship
How did physicists establish the relationship between electric force and distance in the first place?
One important contribution came from French physicist Charles-Augustin de Coulomb in the 1780s.
His experiments helped establish the inverse-square relationship for electrostatic forces.
Coulomb’s torsion balance
Coulomb needed a way to measure extremely small electric forces.
His solution was a device called a torsion balance.
The apparatus consisted of:
- A thin fibre suspended vertically from the top of an enclosure.
- A lightweight horizontal needle attached to the fibre.
- A small charged pith ball attached to one end of the needle.
- A counterweight attached to the other end.
- A second charged pith ball mounted on an insulated support nearby.
The arrangement allowed the second charged ball to be brought towards the suspended ball without physically touching the apparatus.
When two similarly charged balls approached each other, they repelled.
This caused the suspended needle to rotate, twisting the fibre.
The fibre resisted this rotation. By calibrating its resistance to twisting, Coulomb could relate the angle of rotation to the force acting on the suspended ball.
He could also vary and measure the separation between the centres of the charged balls.
What should the experiment show?
Suppose the electrostatic force follows an inverse-square relationship.
If the distance between two charges doubles, the force should become one-quarter as large.
Mathematically:
\[ F\propto\frac{1}{r^2} \]
Coulomb’s measurements supported this inverse-square relationship.
This was important because it gave physicists a quantitative way to predict how electrostatic interactions change with distance.
What happened when the charges attracted?
The original arrangement worked well for repelling charges, but opposite charges introduced a problem.
If the balls attracted strongly enough, they could jump together and stick. That ended the measurement.
Coulomb therefore used a different experimental arrangement to investigate attraction.
He used a small charged plate attached to a suspended needle and an oppositely charged hollow conducting sphere. Rather than simply measuring the twist caused by a nearby ball, he measured the oscillation period of the suspended arrangement at different distances.
This provided an independent way of investigating the force-distance relationship.
These historical details are described in the American Physical Society’s account of Coulomb’s torsion balance.
A small scale calculation
Suppose an illustrative measurement gives an electrostatic force of \(0.36\text{ mN}\) when two charges are separated by \(0.10\text{ m}\).
What force would the inverse-square model predict at \(0.20\text{ m}\)?
The distance has doubled, so:
\[ \frac{F_2}{F_1} = \left(\frac{r_1}{r_2}\right)^2 \]
Substituting:
\[ \frac{F_2}{0.36} = \left(\frac{0.10}{0.20}\right)^2 \]
\[ \frac{F_2}{0.36}=0.25 \]
Therefore:
\[ F_2=0.090\text{ mN} \]
The force has fallen to one-quarter of its original value.
These numbers are illustrative, not Coulomb’s recorded experimental measurements.
What does this have to do with field lines?
Coulomb measured forces, not invisible lines in space.
However, we can divide the force on a test charge by that charge to obtain electric field strength.
For a fixed test charge, if the force falls to one-quarter, the electric field strength also falls to one-quarter.
The field-line diagram gives us a visual way to represent this change.
This separates three ideas:
- Historical observation: electrostatic forces follow an inverse-square relationship for point charges.
- Physical interpretation: the electric field strength also follows an inverse-square relationship around an isolated point charge.
- Diagram convention: field lines are drawn with lower density where the field is weaker.
04Why field lines spread out around a point charge
An isolated point charge produces a radial electric field.
For a positive source charge, field lines point outwards. For a negative source charge, they point inwards.
The electric field strength is:
\[ E=\frac{k|Q|}{r^2} \]
Where:
- \(E\) is electric field strength in \(\text{N C}^{-1}\).
- \(k\) is Coulomb’s constant, approximately \(8.99\times10^9\text{ N m}^2\text{C}^{-2}\).
- \(Q\) is the source charge in coulombs (C).
- \(r\) is the distance from the centre of the source charge in metres (m).
The absolute value of \(Q\) gives the field magnitude. The sign of \(Q\) determines the direction.
The geometric reason for the inverse-square relationship
Picture a point charge surrounded by an imaginary spherical surface.
The area of a sphere is:
\[ A=4\pi r^2 \]
Now double the radius.
The new surface area is:
\[ A_2=4\pi(2r)^2 \]
\[ A_2=16\pi r^2 \]
The original area was \(4\pi r^2\), so the new surface area is four times larger.
The same radial field lines cross both spherical surfaces. They are simply spread across a larger area at the greater radius.
Therefore, the field-line density becomes one-quarter as large.
This is the geometric reason that the field around a point charge weakens according to an inverse-square relationship.
The following table summarises what happens when the distance from an isolated point charge changes.
| Distance from source | Surface area relative to original | Field strength relative to original |
|---|---|---|
| \(r\) | 1 | 1 |
| \(2r\) | 4 | \(1/4\) |
| \(3r\) | 9 | \(1/9\) |
| \(r/2\) | \(1/4\) | 4 |
A common mistake is to assume that doubling the distance halves the field strength.
That would describe an inverse relationship, not an inverse-square relationship.
For a point charge, doubling the distance makes the field four times weaker.
There is also a limitation worth remembering when interpreting diagrams: a flat radial sketch is only a two-dimensional cross-section of a three-dimensional field. You should not use the measured gap between radial lines on a flat page to calculate the exact inverse-square relationship. Use the point-charge equation or the three-dimensional surface-area argument.
For more practice reading radial patterns, see Electric Field Lines Around a Point Charge: HSC Physics Guide.
Worked example: Compare the field at two distances from a point charge
A positive point charge of \(3.0\text{ nC}\) produces an electric field at two locations:
- Point A is \(0.10\text{ m}\) from the charge.
- Point B is \(0.20\text{ m}\) from the charge.
Calculate the electric field strength at both points and determine their ratio.
Step 1
Because the source is an isolated point charge, use:
\[ E=\frac{k|Q|}{r^2} \]
The source charge is:
\[ Q=3.0\times10^{-9}\text{ C} \]
Step 2
Substitute the known values:
\[ E_A= \frac{(8.99\times10^9)(3.0\times10^{-9})} {(0.10)^2} \]
\[ E_A=\frac{26.97}{0.010} \]
\[ E_A=2697\text{ N C}^{-1} \]
Therefore:
\[ E_A=2.7\times10^3\text{ N C}^{-1} \]
Step 3
\[ E_B= \frac{(8.99\times10^9)(3.0\times10^{-9})} {(0.20)^2} \]
\[ E_B=\frac{26.97}{0.040} \]
\[ E_B=674.25\text{ N C}^{-1} \]
Therefore:
\[ E_B=6.7\times10^2\text{ N C}^{-1} \]
Step 4
\[ \frac{E_A}{E_B} = \frac{2697}{674.25} \]
\[ \frac{E_A}{E_B}=4 \]
The electric field at A is four times stronger than at B.
This is why the field lines should be more closely spaced near A. The field has weakened because the same radial pattern spreads across a larger spherical surface.
05The important contrast: Uniform electric fields
So far, we have focused on point charges.
But does every electric field become weaker as you move further away from its source?
No. This is where uniform electric fields provide an important contrast.
Consider two large, oppositely charged parallel metal plates.
One plate is positive, and the other is negative. The electric field between them is approximately uniform throughout the central region.
A uniform electric field has:
- Constant magnitude.
- Constant direction.
- Parallel, equally spaced field lines.
Notice something important.
If you move a test charge from a position close to the positive plate to another position further away, the electric field strength does not decrease, provided both positions remain within the central uniform region.
The field lines remain equally spaced.
This is different from the radial field around a point charge.
Why is the field uniform?
The parallel plates are extended charged surfaces rather than isolated point charges.
Their combined electric field is approximately constant in magnitude and direction across the central gap.
For sufficiently large parallel plates, the field strength is:
\[ E\approx\frac{|\Delta V|}{d} \]
Where:
- \(E\) is electric field strength in \(\text{V m}^{-1}\) or \(\text{N C}^{-1}\).
- \(\Delta V\) is the potential difference between the plates in volts (V).
- \(d\) is the perpendicular separation between the plates in metres (m).
The approximation applies away from the plate edges, where fringing effects are small.
This equation is useful because it shows that the field depends on the potential difference and plate separation, not on how far a test charge is from either plate within the uniform region.
For more detail on this calculation, see How to Calculate Electric Field Strength Between Parallel Plates.
Point-charge fields versus uniform fields
| Feature | Point-charge field | Uniform field |
|---|---|---|
| Typical source | Isolated point charge | Large parallel plates |
| Field direction | Radial | Constant |
| Field-line pattern | Lines spread out or converge | Parallel, equally spaced lines |
| Field strength | Decreases with \(r^2\) | Approximately constant |
| Main equation | \(E=k|Q|/r^2\) | \(E\approx|\Delta V|/d\) |
The key decision is to identify the type of field before choosing an equation.
Do not automatically use the inverse-square relationship just because a test charge has moved further from a charged object.
06Worked example: Using field-line density to calculate force
A field-line diagram contains two regions, P and Q.
In region P, 12 field lines cross a perpendicular area of \(3.0\text{ cm}^2\).
In region Q, 8 field lines cross a perpendicular area of \(4.0\text{ cm}^2\).
Both regions use the same drawing convention, and the field arrows point east.
A positive \(2.0\,\mu\text{C}\) test charge placed at P experiences a force of \(0.080\text{ N}\).
Calculate:
- The ratio of electric field strengths at P and Q.
- The electric field strength at each location.
- The force on a negative \(1.0\,\mu\text{C}\) charge placed at Q.
Step 1
At P:
\[ D_P=\frac{12}{3.0}=4.0 \]
At Q:
\[ D_Q=\frac{8}{4.0}=2.0 \]
These are illustrative line densities in lines per square centimetre.
Step 2
Electric field strength is proportional to field-line density.
Therefore:
\[ \frac{E_P}{E_Q} = \frac{D_P}{D_Q} \]
\[ \frac{E_P}{E_Q} = \frac{4.0}{2.0} \]
\[ E_P=2E_Q \]
The field at P is twice as strong as the field at Q.
Step 3
Use the relationship:
\[ E=\frac{F}{q} \]
Substitute:
\[ E_P= \frac{0.080}{2.0\times10^{-6}} \]
\[ E_P=4.0\times10^4\text{ N C}^{-1} \]
Step 4
Since P has twice the field strength:
\[ E_Q=\frac{E_P}{2} \]
\[ E_Q=\frac{4.0\times10^4}{2} \]
\[ E_Q=2.0\times10^4\text{ N C}^{-1} \]
Step 5
Use:
\[ \vec F=q\vec E \]
The negative charge is:
\[ q=-1.0\times10^{-6}\text{ C} \]
Therefore:
\[ F=(-1.0\times10^{-6})(2.0\times10^4) \]
\[ F=-2.0\times10^{-2}\text{ N} \]
The negative sign indicates that the force acts opposite to the electric field.
The force has a magnitude of \(0.020\text{ N}\), directed west.
Notice that the electric field at Q points east, even though the negative charge experiences a force west.
07A reliable way to interpret field-line diagrams
When you encounter an electric field diagram in an HSC Physics question, use the following approach.
First: Identify the field arrangement.
Is it an isolated point charge, a uniform field between parallel plates, or a more complicated arrangement of several charges?
Second: Read the arrows.
The arrows show the direction of the electric field, defined using a positive test charge.
Third: Compare the local line density.
Look at how many lines pass through equal areas perpendicular to the field.
- More closely spaced lines indicate a stronger field.
- More widely spaced lines indicate a weaker field.
- Equal spacing indicates a constant field strength in that region, provided the field lines are drawn consistently.
Fourth: Choose the appropriate physical model.
For an isolated point charge, use:
\[ E=\frac{k|Q|}{r^2} \]
For the central region between parallel plates, use:
\[ E\approx\frac{|\Delta V|}{d} \]
For several source charges, remember that the electric field is the vector sum of their individual fields.
Common misconceptions
| Incorrect prediction | Correct understanding |
|---|---|
| More total field lines always means a stronger field at every location. | Compare the number of lines per unit perpendicular area. |
| Doubling the distance from a point charge halves the field. | Doubling the distance makes the field one-quarter as strong. |
| A larger test charge creates a stronger original field. | The source charges determine the field; the test charge determines the force it experiences. |
| A negative test charge experiences a force in the direction of the field. | Its force acts opposite to the field. |
| Every electric field weakens with distance. | A uniform field has constant strength throughout its uniform region. |
| Field lines are physical objects. | They are a visual representation of the electric field. |
08Questions and solutions
The following questions build from basic field-line interpretation to more demanding applications involving inverse-square relationships, uniform fields, and superposition.
Question 1
Two locations, A and B, lie within the same electric field diagram.
The field lines are approximately parallel in both regions. Their perpendicular separation is:
- At A: \(2.0\text{ mm}\).
- At B: \(6.0\text{ mm}\).
Assume the diagram uses the same drawing scale and convention throughout.
Calculate the ratio \(E_A/E_B\).
Solution 1
The electric field at A is three times stronger than the electric field at B.
For approximately parallel field lines, the number of lines crossing a fixed perpendicular distance is inversely proportional to their separation.
Therefore:
\[ E\propto\frac{1}{s} \]
Where \(s\) is the perpendicular separation between neighbouring field lines.
The ratio is:
\[ \frac{E_A}{E_B} = \frac{s_B}{s_A} \]
Substituting:
\[ \frac{E_A}{E_B} = \frac{6.0}{2.0} \]
\[ \boxed{\frac{E_A}{E_B}=3} \]
The smaller separation at A indicates a greater field-line density, so the field is stronger there.
Remember that this is a relative comparison using the same local drawing convention. It does not mean that the electric field strength is numerically equal to the reciprocal of the measured spacing.
Question 2
Two large parallel plates are separated by \(12\text{ cm}\) and maintained at a potential difference of \(600\text{ V}\).
Points A and B are located within the central region of the plates:
- A is \(2.0\text{ cm}\) from the positive plate.
- B is \(9.0\text{ cm}\) from the positive plate.
A positive \(3.0\,\mu\text{C}\) charge is placed at A, and a negative \(2.0\,\mu\text{C}\) charge is placed at B.
Calculate:
(a) The electric field strength between the plates.
(b) The ratio of the electric field strengths at A and B.
(c) The magnitude and direction of the force on each test charge.
Solution 2
The field strength is \(5.0\times10^3\text{ N C}^{-1}\) at both points. The positive charge experiences a force of \(0.015\text{ N}\) to the right, while the negative charge experiences a force of \(0.010\text{ N}\) to the left.
(a) Calculate the electric field strength.
The plates produce an approximately uniform electric field, so:
\[ E=\frac{|\Delta V|}{d} \]
Convert the separation into metres:
\[ d=12\text{ cm}=0.12\text{ m} \]
Substitute:
\[ E=\frac{600}{0.12} \]
\[ E=5000\text{ V m}^{-1} \]
Since \(\text{V m}^{-1}\) is equivalent to \(\text{N C}^{-1}\):
\[ E=5.0\times10^3\text{ N C}^{-1} \]
The electric field points from the positive plate towards the negative plate, which is to the right.
(b) Compare the field strengths.
The field is uniform in the central region.
Therefore:
\[ E_A=E_B \]
And:
\[ \frac{E_A}{E_B}=1 \]
Although A and B are at different distances from the positive plate, the electric field strength is unchanged.
(c) Calculate the forces.
For the positive charge at A:
\[ F_A=qE \]
\[ F_A=(3.0\times10^{-6})(5.0\times10^3) \]
\[ F_A=0.015\text{ N} \]
The force is to the right because the charge is positive.
For the negative charge at B:
\[ F_B=|q|E \]
\[ F_B=(2.0\times10^{-6})(5.0\times10^3) \]
\[ F_B=0.010\text{ N} \]
The force is to the left because the charge is negative.
This question exposes an important misconception: moving further from a plate does not automatically make the field weaker. The field remains constant throughout the central uniform region.
Question 3
An isolated positive point charge of \(6.0\text{ nC}\) is located at the origin.
Two points are positioned along the positive x-axis:
- Point A is \(0.20\text{ m}\) from the source charge.
- Point B is \(0.50\text{ m}\) from the source charge.
A negative test charge of \(2.0\text{ nC}\) is placed at B.
Calculate:
(a) The electric field strength at A.
(b) The electric field strength at B.
(c) The ratio \(E_A/E_B\).
(d) The magnitude and direction of the force on the negative test charge at B.
Solution 3
The field at A is approximately \(1.35\times10^3\text{ N C}^{-1}\), and the field at B is approximately \(2.16\times10^2\text{ N C}^{-1}\). The field at A is 6.25 times stronger. The negative test charge experiences a force of approximately \(4.3\times10^{-7}\text{ N}\) towards the source charge.
(a) Calculate the field at A.
Use the point-charge equation:
\[ E=\frac{k|Q|}{r^2} \]
Substitute:
\[ E_A= \frac{(8.99\times10^9)(6.0\times10^{-9})} {(0.20)^2} \]
\[ E_A=\frac{53.94}{0.040} \]
\[ E_A=1348.5\text{ N C}^{-1} \]
Therefore:
\[ E_A\approx1.35\times10^3\text{ N C}^{-1} \]
(b) Calculate the field at B.
\[ E_B= \frac{(8.99\times10^9)(6.0\times10^{-9})} {(0.50)^2} \]
\[ E_B=\frac{53.94}{0.25} \]
\[ E_B=215.76\text{ N C}^{-1} \]
Therefore:
\[ E_B\approx2.16\times10^2\text{ N C}^{-1} \]
(c) Calculate the ratio.
\[ \frac{E_A}{E_B} = \frac{1348.5}{215.76} \]
\[ \frac{E_A}{E_B}=6.25 \]
The field at A is 6.25 times stronger than at B.
This agrees with the inverse-square relationship:
\[ \frac{E_A}{E_B} = \left(\frac{0.50}{0.20}\right)^2 \]
\[ \frac{E_A}{E_B}=6.25 \]
(d) Calculate the force on the negative test charge.
The magnitude of the force is:
\[ F=|q|E_B \]
Substitute:
\[ F=(2.0\times10^{-9})(215.76) \]
\[ F=4.3152\times10^{-7}\text{ N} \]
The electric field points away from the positive source charge.
However, the test charge is negative, so its force acts in the opposite direction.
Therefore, the force is approximately:
\[ F=4.3\times10^{-7}\text{ N} \]
directed towards the positive source charge.
Question 4
Two separate electric field diagrams are drawn using the same convention for representing source charge.
Diagram A shows:
- A positive source charge of \(2.0\text{ nC}\).
- A spherical surface of radius \(0.10\text{ m}\).
Diagram B shows:
- A positive source charge of \(8.0\text{ nC}\).
- A spherical surface of radius \(0.40\text{ m}\).
The field-line drawing convention means that the total number of lines leaving a source charge is proportional to its magnitude.
A student notices that four times as many field lines cross the spherical surface in diagram B. They conclude that the electric field must be four times stronger in B.
Evaluate this conclusion.
Calculate \(E_B/E_A\), and explain why counting the total number of field lines gives the wrong prediction.
Solution 4
The student’s conclusion is incorrect. The electric field in diagram B is one-quarter as strong as the electric field in diagram A.
The mistake is comparing the total number of lines instead of their density across the spherical surfaces.
Step 1: Calculate the ratio using the point-charge equation.
\[ E=\frac{k|Q|}{r^2} \]
For two different source charges:
\[ \frac{E_B}{E_A} = \frac{Q_B}{Q_A} \left(\frac{r_A}{r_B}\right)^2 \]
Substitute:
\[ \frac{E_B}{E_A} = \frac{8.0}{2.0} \left(\frac{0.10}{0.40}\right)^2 \]
\[ =4(0.25)^2 \]
\[ =4(0.0625) \]
\[ \frac{E_B}{E_A}=0.25 \]
Therefore:
\[ E_B=\frac14E_A \]
Step 2: Explain the field-line density.
The source charge in B is four times larger, so four times as many lines are drawn.
However, the radius is also four times larger.
The spherical surface area is proportional to the square of the radius:
\[ \frac{A_B}{A_A} = \left(\frac{0.40}{0.10}\right)^2 \]
\[ \frac{A_B}{A_A}=16 \]
The outer spherical surface in B has 16 times the area of the surface in A.
Therefore, four times as many lines are spread over 16 times the area.
The relative line density is:
\[ \frac{D_B}{D_A}=\frac{4}{16} \]
\[ \frac{D_B}{D_A}=\frac14 \]
This matches the calculated electric field ratio.
The important lesson is that the number of lines leaving a source tells you about the source charge in the chosen drawing convention. The local density tells you about the electric field strength at a particular location.
Question 5
Two positive point charges are fixed on the horizontal x-axis.
- Charge \(Q_1=+2.0\text{ nC}\) is positioned at \(x=0\).
- Charge \(Q_2=+8.0\text{ nC}\) is initially positioned at \(x=0.60\text{ m}\).
Point P is located at \(x=0.20\text{ m}\).
Take the positive x-direction to be towards the right.
A student argues that the electric field at P must point to the right because P is closer to the smaller positive charge.
Investigate this claim.
(a) Calculate the individual electric field strengths produced by \(Q_1\) and \(Q_2\) at P, including their directions.
(b) Determine the resultant electric field at P.
(c) A sufficiently small test charge at P is changed from \(+2.0\text{ pC}\) to \(-4.0\text{ pC}\). Explain whether the electric field changes and calculate the force on each test charge while the source charges remain in their original positions.
(d) The larger source charge is then moved from \(x=0.60\text{ m}\) to \(x=0.80\text{ m}\). The smaller source charge and point P remain fixed. Calculate the new resultant electric field and the force on the \(-4.0\text{ pC}\) test charge.
(e) Explain how the field-line direction and density around P should change between the original and modified arrangements.
Assume the source charges are point-like, the test charge does not significantly disturb the source arrangement, and the surrounding medium is air.
Solution 5
The original electric field at P is zero because the two source charges produce equal-strength fields in opposite directions. After the larger charge moves further away, the resultant field becomes \(250\text{ N C}^{-1}\) to the right, and the negative test charge experiences a force of \(1.0\times10^{-9}\text{ N}\) to the left.
This problem demonstrates why field-line density must represent the resultant electric field, rather than the individual contributions from each source charge.
(a) Calculate the individual fields at P.
Start with the smaller positive source charge.
Its magnitude is:
\[ Q_1=2.0\times10^{-9}\text{ C} \]
Its distance from P is:
\[ r_1=0.20\text{ m} \]
Using the point-charge equation:
\[ E_1=\frac{k|Q_1|}{r_1^2} \]
\[ E_1= \frac{(8.99\times10^9)(2.0\times10^{-9})} {(0.20)^2} \]
\[ E_1=\frac{17.98}{0.040} \]
\[ E_1=449.5\text{ N C}^{-1} \]
Because P is to the right of a positive charge, this field points to the right.
Therefore:
\[ \vec E_1=+449.5\hat i\text{ N C}^{-1} \]
Now consider the larger source charge.
Its magnitude is:
\[ Q_2=8.0\times10^{-9}\text{ C} \]
Its distance from P is:
\[ r_2=0.60-0.20=0.40\text{ m} \]
Calculate its field:
\[ E_2=\frac{k|Q_2|}{r_2^2} \]
\[ E_2= \frac{(8.99\times10^9)(8.0\times10^{-9})} {(0.40)^2} \]
\[ E_2=\frac{71.92}{0.16} \]
\[ E_2=449.5\text{ N C}^{-1} \]
Because P is to the left of the larger positive charge, its field points to the left.
Therefore:
\[ \vec E_2=-449.5\hat i\text{ N C}^{-1} \]
(b) Determine the resultant electric field.
Electric fields are vectors, so their directions must be considered when adding them.
\[ \vec E_{\text{net}}=\vec E_1+\vec E_2 \]
Substitute:
\[ \vec E_{\text{net}} = 449.5\hat i-449.5\hat i \]
\[ \vec E_{\text{net}}=0 \]
The electric field at P is zero.
This is a particularly interesting result.
P is closer to the smaller charge, but the larger charge produces an equally strong field because its greater charge magnitude compensates for its greater distance.
Neither source produces zero field individually. Their contributions simply cancel.
At this exact point, the electric field has zero magnitude, so its direction is undefined.
(c) Replace the test charge.
The electric field is determined by the two source charges and their positions.
Changing the test charge does not change the original field, provided the test charge is sufficiently small.
For the positive test charge:
\[ F=qE \]
\[ F=(2.0\times10^{-12})(0) \]
\[ F=0\text{ N} \]
For the negative test charge:
\[ F=(-4.0\times10^{-12})(0) \]
\[ F=0\text{ N} \]
Both test charges experience zero net electric force at P.
Notice that changing the sign and magnitude of the test charge does not change the electric field.
(d) Move the larger source charge to \(x=0.80\text{ m}\).
The smaller charge remains at \(x=0\), so its field at P is unchanged:
\[ E_1=449.5\text{ N C}^{-1} \]
The new distance from the larger charge to P is:
\[ r_2=0.80-0.20 \]
\[ r_2=0.60\text{ m} \]
Calculate its new field:
\[ E_2= \frac{(8.99\times10^9)(8.0\times10^{-9})} {(0.60)^2} \]
\[ E_2=\frac{71.92}{0.36} \]
\[ E_2\approx199.8\text{ N C}^{-1} \]
This field still points to the left.
Now calculate the resultant field:
\[ E_{\text{net}}=449.5-199.8 \]
\[ E_{\text{net}}=249.7\text{ N C}^{-1} \]
Therefore:
\[ E_{\text{net}}\approx250\text{ N C}^{-1} \]
directed to the right.
Calculate the force on the negative test charge:
\[ F=qE \]
\[ F=(-4.0\times10^{-12})(249.7) \]
\[ F=-9.99\times10^{-10}\text{ N} \]
The negative sign indicates that the force points left.
Therefore, the force has a magnitude of:
\[ F\approx1.0\times10^{-9}\text{ N} \]
directed to the left.
(e) Explain the change in field-line density.
In the original arrangement, the two source fields cancel exactly at P.
The resultant electric field is zero there, so there is no defined electric field direction at that point.
After moving the larger charge further away, its contribution becomes weaker because of the inverse-square relationship.
The smaller charge now produces the stronger contribution, leaving a resultant field directed to the right.
The field-line representation must reflect this change:
- Originally, P is an electric-field null point.
- After the larger charge moves, the resultant field at P is non-zero and points right.
- The local field-line density must represent the magnitude of this resultant field.
This is the deeper lesson: being closer to one charge does not necessarily mean experiencing a stronger net electric field. The contributions from all source charges must be combined as vectors first.
09Where to go next
You now have two ways to interpret electric field strength.
The mathematical approach uses the appropriate field equation, such as the inverse-square equation for a point charge or the uniform-field equation between parallel plates.
The visual approach uses field-line density: closer lines represent a stronger resultant electric field.
The next useful connection is electric potential and equipotential lines. Just as closely spaced electric field lines indicate a stronger field, closely spaced equipotential lines indicate a larger change in electric potential over a given distance.
Understanding how these two representations connect will help you interpret more complicated electric field diagrams without relying on memorised patterns.