Which Ions Move Through a Salt Bridge in a Galvanic Cell?

Learn why anions migrate towards the anode and cations towards the cathode in a galvanic cell. Explore electrode reactions, charge balance, standard cell potentials, worked examples, and challenging HSC Chemistry questions.

An iron strip is slowly dissolving in one beaker while silver metal is building up on an electrode in another. The beakers are connected by a potassium nitrate salt bridge. Which ion should move towards the dissolving iron: \(\mathrm{K}^{+}\) or \(\ce{NO3-}\)?

It’s nitrate, \(\ce{NO3-}\). In a working galvanic cell, anions migrate towards the anode, where oxidation occurs, while cations migrate towards the cathode, where reduction occurs. The reason is charge balance in the solutions, not attraction to the metal electrodes.

For a \(\ce{KNO3}\) salt bridge:

  • \(\ce{NO3-}\) migrates towards the anode.
  • \(\mathrm{K}^{+}\) migrates towards the cathode.
  • Electrons travel through the external wire, not the salt bridge.

Those are the expected net migration directions. Individual ions can also diffuse in other directions, which becomes important when choosing a bridge electrolyte and interpreting experiments.

Front view of an iron–silver galvanic cell. An iron strip sits in pale-green iron(II) sulfate solution and a silver electrode sits in clear silver nitrate solution. A U-shaped potassium nitrate salt bridge joins the beakers, while an external wire connects the electrodes through a voltmeter.
The iron anode and silver cathode are linked by an external circuit and a KNO₃ salt bridge that maintains charge balance.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

01Start with an experiment: why does the bridge change the result?

Imagine testing whether iron can transfer electrons to silver ions without placing the two chemicals in the same beaker.

The first design uses two separate containers:

  1. An iron electrode sits in \(\ce{FeSO4(aq)}\), containing \(\mathrm{Fe}^{2+}\) ions.
  2. A silver electrode sits in \(\ce{AgNO3(aq)}\), containing \(\mathrm{Ag}^{+}\) ions.
  3. A wire, switch, and ammeter connect the metal electrodes.
  4. There is initially no connection between the liquids.

Iron can lose electrons, and silver ions can gain them. You might predict that closing the switch will produce a sustained current.

It doesn’t.

A small, short-lived current may occur, but charge separation rapidly opposes further electron transfer. The wire can carry electrons, but there is no continuous ionic pathway between the solutions.

Revising the apparatus

Now add a U-shaped tube filled with potassium nitrate solution held in an agar gel. One end dips into the iron solution; the other dips into the silver solution.

This provides an ionic connection without freely pouring the two solutions together.

Close the switch again. The predicted observations are now different:

  • Iron gradually loses mass as atoms enter its solution.
  • Silver deposits onto the silver electrode.
  • Current can continue through the external circuit while the reaction has a driving force and reactants remain available.

These are established electrochemical predictions, not measurements from a particular experiment.

Side-by-side iron–silver galvanic cells with ammeters and closed switches. The unbridged cell loses sustained current; the cell with a potassium nitrate agar-gel U-tube shows iron dissolving and silver depositing.
Qualitative prediction: the gel bridge restores ionic continuity, allowing sustained current while iron dissolves and silver is deposited.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The revised design tells us that ionic conduction is necessary. It doesn’t, by itself, measure which individual ions cross the bridge.

To predict their directions, we need to follow what happens to charge in each beaker.

For a fuller explanation of why the original arrangement stops working, see Why a Galvanic Cell Needs a Salt Bridge to Keep Current Flowing.

02Follow the electrode reactions to find the ion directions

At the iron anode: positive ions are produced

Iron undergoes oxidation:

\[ \ce{Fe(s) -> Fe^2+(aq) + 2e^-} \]

Each iron atom loses two electrons and enters the solution as an \(\mathrm{Fe}^{2+}\) ion.

The electrons travel into the external circuit. The new positive ion remains in the iron half-cell.

If nothing else changed, that solution would develop an excess of positive charge.

The salt bridge provides a response: negatively charged nitrate ions migrate towards the iron half-cell.

At the silver cathode: positive ions are removed

Silver ions undergo reduction:

\[ \ce{2Ag+(aq) + 2e^- -> 2Ag(s)} \]

Two silver ions gain two electrons and become solid silver.

Those silver ions are removed from the solution. Their accompanying nitrate ions remain in solution.

Without compensating ion movement, the silver half-cell would develop an excess of negative charge.

Positively charged potassium ions therefore migrate towards the silver half-cell.

Iron-silver galvanic cell showing an iron anode in FeSO₄ solution and a silver cathode in AgNO₃ solution. Electrons travel left to right through the external wire, while NO₃⁻ migrates towards the iron anode and K⁺ towards the silver cathode through a KNO₃ salt bridge.
Electrons travel through the external wire, while NO₃⁻ and K⁺ migrate through the salt bridge to maintain electrical neutrality in both half-cells.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The charge-balance table

FeatureIron half-cellSilver half-cell
ElectrodeIronSilver
Electrode nameAnodeCathode
ReactionOxidationReduction
Change in dissolved ions\(\mathrm{Fe}^{2+}\) produced\(\mathrm{Ag}^{+}\) consumed
Charge tendency without compensationExcess positive chargeExcess negative charge
Main bridge-ion response\(\ce{NO3-}\) migrates towards it\(\mathrm{K}^{+}\) migrates towards it
Electron directionElectrons leaveElectrons arrive

There’s an important detail here.

The iron solution doesn’t need to become strongly positive before nitrate moves. Only a tiny charge imbalance is needed to establish an electric field that drives ionic migration. During sustained operation, each bulk solution remains approximately electrically neutral.

Also, don’t confuse the charge of the electrode with the charge tendency in its surrounding solution.

In a galvanic cell, the anode is the negative electrode, yet anions migrate towards its half-cell. They aren’t simply being attracted to the negative metal. Their movement is part of maintaining charge balance in the complete electrochemical circuit.

Worked example: Identify the ion movement and cell potential

An iron-silver galvanic cell uses a potassium nitrate salt bridge.

The standard reduction potentials are:

\[ \begin{aligned} \ce{Fe^2+ + 2e^- -> Fe} &\quad -0.44\ \mathrm{V}\\ \ce{Ag+ + e^- -> Ag} &\quad +0.80\ \mathrm{V} \end{aligned} \]

Identify the anode and cathode, calculate the standard cell potential, and predict the direction of electron flow and salt bridge ion migration.

Step 1Identify which reaction is reduction.

The silver half-cell has the more positive standard reduction potential.

Silver ions are therefore reduced at the cathode under standard conditions. Iron undergoes oxidation at the anode.

Step 2Write the balanced electrode reactions.

Anode:

\[ \ce{Fe(s) -> Fe^2+(aq) + 2e^-} \]

Cathode:

\[ \ce{2Ag+(aq) + 2e^- -> 2Ag(s)} \]

Electrons flow from iron to silver through the external wire.

Step 3Calculate the standard cell potential.

Use:

\[ E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{cathode}} - E^\circ_{\mathrm{anode}} \]

Both electrode values must be taken from the standard reduction potential table.

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=(+0.80)-(-0.44)\\ &=+1.24\ \mathrm{V} \end{aligned} \]

Here, \(E^\circ_{\mathrm{cell}}\) is the standard cell potential, measured in volts (V).

The positive result predicts a spontaneous reaction in the stated direction under standard conditions.

Step 4Determine the bridge-ion directions.

Iron oxidation produces positive ions, so \(\ce{NO3-}\) migrates towards the iron anode.

Silver reduction removes positive ions, so \(\mathrm{K}^{+}\) migrates towards the silver cathode.

The result is a cell with a standard potential of \(+1.24\ \mathrm{V}\), electrons moving from iron to silver, and the two bridge ions migrating in opposite directions.

03Do all the bridge ions move in just one direction?

Not quite. This is where the simple HSC model needs one extra layer of precision.

Potassium nitrate dissolves into mobile ions:

\[ \ce{KNO3(aq) -> K+(aq) + NO3-(aq)} \]

Two processes affect their movement.

Migration is ion movement driven by an electric field. This produces the usual direction rules: cations towards the cathode, and anions towards the anode.

Diffusion is the net spreading of particles from regions of higher concentration towards regions of lower concentration.

An individual nitrate ion is not permanently assigned to the anode. It moves randomly through the liquid, while the electric field and concentration gradients influence the overall transport.

Magnified cutaway of a potassium nitrate gel salt bridge connecting an iron anode solution on the left to a silver cathode solution on the right. Hydrated blue K+ and coral NO3− ions are dispersed throughout one continuous liquid-filled interior. Prominent arrows show potassium migrating right towards the cathode and nitrate migrating left towards the anode, while smaller arrows indicate local random motion and possible diffusion.
Hydrated ions share one continuous gel; the electric field biases nitrate toward the iron anode and potassium toward the silver cathode.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

This creates a useful distinction:

  • Predicting the main migration direction requires knowing the electrode reactions.
  • Predicting the exact number of each kind of ion that crosses a boundary requires more information about transport and diffusion.

Both cations and anions can carry ionic current. You cannot generally determine their exact individual contributions just by counting electrons in the wire.

Worked example: How much charge does the bridge compensate?

An iron-silver cell operates at a constant current of \(0.150\ \mathrm{A}\) for \(8.00\) minutes.

Assume the only electrode reactions are iron oxidation and silver-ion reduction, and that every electron contributes to those reactions.

Calculate the amount of iron oxidised and silver deposited. Then explain what the charge passed tells us about the salt bridge.

Use:

  • Faraday constant: \(F=96\,500\ \mathrm{C\,mol^{-1}}\) of electrons
  • Molar mass of iron: \(55.8\ \mathrm{g\,mol^{-1}}\)
  • Molar mass of silver: \(107.9\ \mathrm{g\,mol^{-1}}\)

Step 1Calculate the total electrical charge.

Electrical charge is:

\[ Q=It \]

Here, \(Q\) is charge in coulombs (C), \(I\) is current in amperes (A), and \(t\) is time in seconds (s).

Convert the time:

\[ t=8.00\times60=480\ \mathrm{s} \]

Then:

\[ \begin{aligned} Q&=0.150\times480\\ &=72.0\ \mathrm{C} \end{aligned} \]

Step 2Calculate the amount of electrons transferred.

\[ \begin{aligned} n(e^-)&=\frac{Q}{F}\\ &=\frac{72.0}{96\,500}\\ &=7.46\times10^{-4}\ \mathrm{mol} \end{aligned} \]

The symbol \(n\) means amount of substance, measured in moles (mol).

Step 3Calculate the electrode changes.

Each iron atom produces two electrons.

\[ \begin{aligned} n(\ce{Fe}) &=\frac{7.46\times10^{-4}}{2}\\ &=3.73\times10^{-4}\ \mathrm{mol} \end{aligned} \]

The mass of iron lost is:

\[ \begin{aligned} m(\ce{Fe})&=nM\\ &=(3.73\times10^{-4})(55.8)\\ &=0.0208\ \mathrm{g} \end{aligned} \]

Here, \(m\) is mass in grams (g), and \(M\) is molar mass in \(\mathrm{g\,mol^{-1}}\).

Each silver ion accepts one electron, so:

\[ \begin{aligned} m(\ce{Ag}) &=(7.46\times10^{-4})(107.9)\\ &=0.0805\ \mathrm{g} \end{aligned} \]

The iron electrode loses approximately \(0.0208\ \mathrm{g}\), while the silver electrode gains approximately \(0.0805\ \mathrm{g}\).

Step 4Interpret the salt bridge’s contribution.

The iron reaction introduces \(7.46\times10^{-4}\) mol of positive charge equivalents into its solution. Silver-ion reduction removes the same amount from the silver solution.

In a deliberately simplified model where only nitrate enters the anode compartment and only potassium enters the cathode compartment, each would transfer \(7.46\times10^{-4}\) mol of ions.

But that is a bookkeeping assumption, not an experimentally established ion count.

In a real cell, the electrolyte ions already present in the half-cells can move, and diffusion can also occur. The electron count fixes the total electrical charge transferred, not the exact amounts of individual bridge ions crossing each interface.

Iron-silver galvanic cell with an iron anode in iron sulfate solution and a silver cathode in silver nitrate solution. A potassium nitrate salt bridge connects the half-cells, with nitrate ions migrating left and potassium ions right. Electrons flow through an external resistor and an ammeter reading 0.150 A. An adjacent digital timer reads 8.00 minutes. The iron electrode is slightly thinner below the solution surface, while the silver electrode has a visible metallic deposit.
Nitrate ions migrate towards the iron anode while potassium ions migrate towards the silver cathode, maintaining electrical neutrality in both half-cells.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

04Why the choice of salt bridge electrolyte matters

Suppose you replace \(\ce{KNO3}\) with potassium chloride, \(\ce{KCl}\).

The general migration rules don’t change:

  • \(\mathrm{Cl}^{-}\) migrates towards the anode.
  • \(\mathrm{K}^{+}\) migrates towards the cathode.

But the chemical compatibility might change dramatically.

In a cell containing silver ions, chloride can form insoluble silver chloride:

\[ \ce{Ag+(aq) + Cl-(aq) -> AgCl(s)} \]

A tempting argument is that chloride must be safe if the silver electrode is the cathode, because chloride’s net electrical migration is towards the opposite half-cell.

That overlooks diffusion. Some chloride can still enter the silver solution through the liquid junction, even while its electrically driven migration has the opposite net direction.

Removing \(\mathrm{Ag}^{+}\) by precipitation can change the silver electrode’s potential and interfere with the intended cell reaction.

Side-by-side close-ups of potassium nitrate and potassium chloride salt bridge ends immersed in silver nitrate solution. Both contain dissolved ions. The potassium chloride junction forms a small white silver chloride precipitate as chloride diffuses into the solution, while its opposing net electrical migration points toward the anode.
Chloride can diffuse into silver nitrate solution and form AgCl, even while its net electrical migration is directed away from the silver cathode.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

This is why choosing a suitable bridge electrolyte involves more than memorising ion directions.

Potassium nitrate is often useful because its ions are soluble and do not readily interfere with many common half-cell reactions. However, no electrolyte is automatically compatible with every chemical system.

05Standard potentials and actual voltmeter readings

Salt bridge questions often combine ion directions with standard electrode potentials. There are two conventions worth keeping separate.

Standard reduction potentials determine the reference cell voltage

Standard electrode potentials are tabulated as reduction potentials, measured relative to the standard hydrogen electrode.

For HSC calculations, standard conditions are commonly represented by:

  • Aqueous species at approximately \(1.0\ \mathrm{mol\,L^{-1}}\)
  • Gases at a standard pressure of \(100\ \mathrm{kPa}\)
  • A tabulated temperature of \(25^\circ\mathrm{C}\), or approximately \(298\ \mathrm{K}\)

Strictly, standard electrode potentials are defined using unit activities rather than simply concentrations. The temperature is stated with the tabulated potential; \(25^\circ\mathrm{C}\) is the usual reference temperature, not a universal requirement of a standard state.

For the iron-silver cell:

Standard reduction half-reaction\(E^\circ_{\mathrm{red}}\)
\(\ce{Fe^2+ + 2e^- -> Fe}\)\(-0.44\ \mathrm{V}\)
\(\ce{Ag+ + e^- -> Ag}\)\(+0.80\ \mathrm{V}\)

The standard cell potential is \(+1.24\ \mathrm{V}\).

You do not multiply a standard electrode potential when multiplying its half-equation to balance electrons. Potential is energy transferred per unit charge, not total energy.

A measured potential belongs to the actual conditions

Now suppose an illustrative iron-silver cell gives an open-circuit reading of \(+1.18\ \mathrm{V}\), with the voltmeter’s positive lead on silver and its negative lead on iron.

This does not contradict the standard value of \(+1.24\ \mathrm{V}\).

The real solutions might not have unit activities. Temperature, liquid junction potentials, and other practical effects can also influence the reading.

QuantityMeaning
\(E^\circ_{\mathrm{cell}}=+1.24\ \mathrm{V}\)Standard potential calculated from tabulated reduction potentials
\(E_{\mathrm{cell}}=+1.18\ \mathrm{V}\)Illustrative open-circuit measurement under actual conditions
Voltmeter reads \(-1.18\ \mathrm{V}\) after reversing its leadsSame physical cell, but reversed measurement polarity

The \(1.18\ \mathrm{V}\) value is illustrative data, not a reported experimental result.

Two views of the same iron-silver galvanic cell. The voltmeter reads +1.18 V with red on silver and black on iron, then −1.18 V after the leads are reversed. The KNO3 bridge, ion migration and electrode reactions remain unchanged.
Swapping the voltmeter leads reverses the illustrative reading, while iron oxidation, silver-ion reduction and KNO₃ bridge-ion migration continue unchanged.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The voltmeter measures the potential difference between its terminals. Reversing the leads changes the displayed sign, not the direction in which the spontaneous reaction proceeds.

One more limitation: a high-resistance voltmeter draws very little current. Once a resistor or other load is connected, current flows and the terminal voltage can differ because of internal resistance and electrode effects.

A damaged or disconnected salt bridge can therefore prevent sustained current without making the high-resistance voltmeter instantly read zero.

The bridge also helps reduce unwanted liquid junction potentials. These small potentials can arise where solutions of different composition meet and their ions diffuse at different rates.

06A contrasting case: both electrodes are copper

What if the two electrodes are identical?

Consider two copper electrodes, each in copper sulfate solution:

  • Left: \(\ce{CuSO4}\) at \(0.100\ \mathrm{mol\,L^{-1}}\)
  • Right: \(\ce{CuSO4}\) at \(1.00\ \mathrm{mol\,L^{-1}}\)

They are connected through an external wire and a potassium nitrate bridge.

Both half-cells use the same reduction reaction:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

So their standard reduction potentials are identical.

The standard cell potential is therefore:

\[ E^\circ_{\mathrm{cell}}=0\ \mathrm{V} \]

Does that mean the cell cannot produce a voltage?

Not necessarily. The actual solutions have different copper-ion concentrations.

Under the usual idealised concentration-cell model, the more concentrated copper-ion solution favours reduction relative to the dilute solution.

As a result:

  • Copper is oxidised at the dilute electrode.
  • Copper ions are reduced at the concentrated electrode.
  • The concentration difference decreases as the cell operates.

This arrangement is called a concentration cell.

Copper concentration cell with two separate copper electrodes in pale-blue 0.100 mol L⁻¹ and deeper-blue 1.00 mol L⁻¹ copper sulfate solutions. A potassium nitrate salt bridge connects the beakers. Electrons move left to right through the external wire, nitrate ions migrate left, and potassium ions migrate right. Copper dissolves at the dilute-side anode and deposits at the concentrated-side cathode.
Copper dissolves at the dilute anode and plates at the concentrated cathode; electrons travel right while nitrate and potassium migrate through the bridge.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The bridge-ion rule still works.

Nitrate migrates towards the dilute-side anode, and potassium migrates towards the concentrated-side cathode.

The subtle point is that the same metal can be an anode or cathode depending on solution conditions.

This is an extension of the usual HSC electrochemical-cell model. You don’t need the Nernst equation to understand the directional reasoning or solve the challenge below.

07Questions and solutions

Question 1

A galvanic cell contains a zinc electrode immersed in zinc sulfate solution and a copper electrode immersed in copper sulfate solution.

The half-cells are connected using a \(\ce{KNO3}\) salt bridge.

Standard reduction potentials:

  • \(\ce{Zn^2+/Zn}\): \(-0.76\ \mathrm{V}\)
  • \(\ce{Cu^2+/Cu}\): \(+0.34\ \mathrm{V}\)

Identify the anode and cathode, calculate the standard cell potential, and state the directions of electron flow, potassium-ion migration, and nitrate-ion migration.

A zinc electrode immersed in zinc sulfate solution and a copper electrode immersed in copper sulfate solution, connected by an inverted U-shaped KNO3 salt bridge and an external wire circuit containing a voltmeter.
The two sulfate half-cells are connected electrically through the external voltmeter circuit and ionically through a KNO₃ salt bridge.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 1

Zinc is the anode, copper is the cathode, and the standard cell potential is \(+1.10\ \mathrm{V}\). Electrons move from zinc to copper, nitrate migrates towards zinc, and potassium migrates towards copper.

Zinc undergoes oxidation:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

Copper ions undergo reduction:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

The more positive standard reduction potential belongs to copper, so copper is reduced.

Using both tabulated reduction potentials:

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{cathode}} -E^\circ_{\mathrm{anode}}\\ &=(+0.34)-(-0.76)\\ &=+1.10\ \mathrm{V} \end{aligned} \]

Zinc oxidation produces positive ions, so nitrate migrates towards the zinc half-cell.

Copper reduction removes positive ions, so potassium migrates towards the copper half-cell.

The trap is following the electron direction when predicting nitrate movement. Electrons travel through the wire; nitrate ions move through the ionic connection for charge balance.

Question 2

A zinc-lead galvanic cell has:

  • A zinc electrode in \(\ce{Zn(NO3)2(aq)}\), on the left
  • A lead electrode in \(\ce{Pb(NO3)2(aq)}\), on the right
  • A potassium sulfate, \(\ce{K2SO4}\), salt bridge

Standard reduction potentials:

  • \(\ce{Zn^2+/Zn}\): \(-0.76\ \mathrm{V}\)
  • \(\ce{Pb^2+/Pb}\): \(-0.13\ \mathrm{V}\)

A student argues:

“The sulfate ions migrate towards zinc, not lead. Therefore, the potassium sulfate bridge cannot interfere with the lead half-cell.”

Determine the standard cell potential, explain whether the student is correct, and recommend a more suitable bridge electrolyte.

A zinc electrode in aqueous zinc nitrate and a lead electrode in aqueous lead nitrate are connected by a potassium sulfate gel salt bridge and an external voltmeter.
A zinc–lead galvanic cell connects two nitrate half-cells through a potassium sulfate gel bridge and an external voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 2

The standard cell potential is \(+0.63\ \mathrm{V}\), and the student’s argument is incorrect. Although sulfate migrates towards the zinc anode, it can also diffuse into the lead solution and precipitate lead sulfate.

First, identify the electrode reactions.

Zinc has the less positive reduction potential and is oxidised:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

Lead ions are reduced:

\[ \ce{Pb^2+(aq) + 2e^- -> Pb(s)} \]

Next, calculate the standard potential.

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=(-0.13)-(-0.76)\\ &=+0.63\ \mathrm{V} \end{aligned} \]

Under the usual migration model:

  • \(\mathrm{SO_{4}}^{2-}\) migrates towards the zinc anode.
  • \(\mathrm{K}^{+}\) migrates towards the lead cathode.

However, the student’s conclusion ignores diffusion.

The potassium sulfate bridge contains sulfate ions at a concentration that may exceed the sulfate concentration in the lead solution. Sulfate can therefore diffuse towards the lead half-cell despite its opposing electrical migration.

If sulfate encounters dissolved lead ions:

\[ \ce{Pb^2+(aq) + SO4^2-(aq) -> PbSO4(s)} \]

Insoluble lead sulfate forms.

This removes \(\mathrm{Pb}^{2+}\) from the solution and can alter the lead electrode potential. How much the measured voltage changes depends on the concentrations and other experimental conditions; it cannot be calculated from the supplied standard potentials alone.

Zinc and lead electrodes in separate nitrate solutions connected by a potassium sulfate U-tube salt bridge. Sulfate ions migrate left towards zinc, potassium ions migrate right towards lead, while a separate diffusion pathway carries some sulfate into the lead solution, forming pale PbSO₄ precipitate.
Electrical migration sends sulfate left and potassium right, but concentration-driven diffusion can still carry sulfate into the lead half-cell, where pale PbSO₄ forms.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

A potassium nitrate bridge would generally be more suitable because nitrate ions do not precipitate lead(II) ions under these conditions.

The governing lesson is that migration direction does not guarantee chemical isolation.

Question 3

A nickel-silver galvanic cell contains:

  • A nickel electrode in excess \(\ce{Ni(NO3)2(aq)}\)
  • A silver electrode in \(50.0\ \mathrm{mL}\) of \(0.0500\ \mathrm{mol\,L^{-1}}\) silver nitrate
  • A calcium nitrate, \(\ce{Ca(NO3)2}\), salt bridge

Standard reduction potentials:

  • \(\ce{Ni^2+/Ni}\): \(-0.25\ \mathrm{V}\)
  • \(\ce{Ag+/Ag}\): \(+0.80\ \mathrm{V}\)

An electronic charge logger reports that \(300\ \mathrm{C}\) passed through the cell.

Assume:

  • The only electrode reactions are nickel oxidation and silver-ion reduction.
  • No silver ions enter from outside the silver half-cell.
  • The nickel metal is available in excess.
  • Side reactions do not occur.

Answer the following.

(a) Is the reported \(300\ \mathrm{C}\) possible under these assumptions?

(b) Calculate the maximum charge and corresponding mass of nickel that could be oxidised.

(c) In a simplified charge-balance model where only bridge nitrate ions enter the anode solution and only bridge calcium ions enter the cathode solution, calculate the amounts of each ion needed up to the maximum charge.

Use \(F=96\,500\ \mathrm{C\,mol^{-1}}\) and \(M(\ce{Ni})=58.7\ \mathrm{g\,mol^{-1}}\).

Schematic nickel-silver galvanic cell with a nickel electrode and nickel nitrate solution on the left, a 50.0 mL 0.0500 mol L⁻¹ silver nitrate compartment on the right, a calcium nitrate salt bridge and an external charge logger reading 300 C.
The nickel and silver half-cells are connected by a calcium nitrate salt bridge, with an external logger displaying the reported charge.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 3

No. The reported \(300\ \mathrm{C}\) is impossible under the stated assumptions. The available silver ions allow a maximum of approximately \(241\ \mathrm{C}\), corresponding to \(0.0734\ \mathrm{g}\) of nickel oxidised.

Part (a): Test the reported charge against the available reactant.

Silver ions are reduced at the cathode:

\[ \ce{Ag+(aq) + e^- -> Ag(s)} \]

The initial amount of silver ions is:

\[ \begin{aligned} n(\mathrm{Ag}^{+})&=cV\\ &=0.0500\times0.0500\\ &=0.00250\ \mathrm{mol} \end{aligned} \]

Here, \(c\) is concentration in \(\mathrm{mol\,L^{-1}}\), and \(V\) is solution volume in litres (L).

Each silver ion accepts one electron.

Therefore:

\[ \begin{aligned} Q_{\max}&=n(e^-)F\\ &=0.00250\times96\,500\\ &=241.25\ \mathrm{C} \end{aligned} \]

The maximum is approximately \(241\ \mathrm{C}\).

The reported \(300\ \mathrm{C}\) exceeds this limit. At least one assumption, measurement, or supplied condition must therefore be wrong.

Part (b): Calculate the nickel oxidised.

Nickel oxidation is:

\[ \ce{Ni(s) -> Ni^2+(aq) + 2e^-} \]

Each mole of nickel produces two moles of electrons.

\[ \begin{aligned} n(\ce{Ni}) &=\frac{0.00250}{2}\\ &=0.00125\ \mathrm{mol} \end{aligned} \]

The mass is:

\[ \begin{aligned} m(\ce{Ni})&=nM\\ &=0.00125\times58.7\\ &=0.0734\ \mathrm{g} \end{aligned} \]

Part (c): Apply the simplified bridge-ion model.

The nickel anode produces \(0.00250\) mol of positive charge equivalents.

Each nitrate ion carries one negative charge, so:

\[ n(\ce{NO3-})=0.00250\ \mathrm{mol} \]

At the cathode, \(0.00250\) mol of positive charge equivalents are removed.

Each calcium ion carries two positive charges, so:

\[ \begin{aligned} n(\mathrm{Ca}^{2+}) &=\frac{0.00250}{2}\\ &=0.00125\ \mathrm{mol} \end{aligned} \]

These are the quantities for the explicitly simplified model. In a real bridge, other ionic fluxes and diffusion mean the individual amounts are not uniquely determined by charge alone.

The tempting mistake is to assume calcium ions can replace silver ions once the silver nitrate is exhausted. But \(\mathrm{Ca}^{2+}\) migration maintains charge balance; it does not replenish \(\mathrm{Ag}^{+}\), and calcium deposition is not an allowed electrode reaction in this question.

The bridge cannot create additional silver reactant simply by carrying more charge.

Question 4

Three iron-silver galvanic cells are investigated at \(25^\circ\mathrm{C}\).

Each uses iron in iron(II) sulfate solution and silver in silver nitrate solution. Where fitted, the salt bridge contains potassium nitrate.

The voltmeter’s positive lead is connected to silver.

The following are illustrative experimental readings, not measured results from a real investigation.

CellConditionsInitial open-circuit voltageBehaviour with a resistor
AStandard-like concentrations, bridge connected\(+1.22\ \mathrm{V}\)Sustains current
BSame as A, but bridge removed\(+1.22\ \mathrm{V}\)Current quickly collapses
CBridge connected, but silver-ion concentration much lower\(+1.10\ \mathrm{V}\)Sustains current

Assume all three cells initially favour iron oxidation and silver-ion reduction, and that the external connections are otherwise identical.

(a) Explain why A and B can initially show the same voltage but behave differently under load.

(b) Explain why C has a lower open-circuit voltage without concluding that its bridge is defective.

(c) Does the evidence establish that C always produces less current than A?

(d) Predict what happens to the displayed voltage sign and the ionic migration directions if the voltmeter leads on C are reversed.

Three side-by-side iron-silver galvanic cells, each with iron and silver electrodes in labelled electrolyte beakers, external voltmeter and switchable resistor. A and C have KNO3 salt bridges; B has no bridge. Initial readings are +1.22 V, +1.22 V and +1.10 V respectively, with C labelled lower Ag+ concentration.
Three iron–silver galvanic cells compare salt-bridge conditions and silver-ion concentration while displaying their illustrative initial open-circuit voltages.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 4

Cell B fails to sustain current because its ionic pathway is missing; cell C sustains current but has a different potential because its chemical conditions differ. The data do not establish which connected cell will supply the larger current.

Part (a): Compare A and B.

With a high-resistance voltmeter, almost no current flows.

The electrodes in B can therefore initially display a potential difference even without a functioning ionic connection between the solutions.

However, when the resistor is connected, electrons begin flowing and charge imbalance develops in the separated solutions.

Without a salt bridge, this imbalance opposes further redox reaction. The current quickly collapses.

Cell A has an ionic pathway, so it can maintain approximate charge neutrality while current flows.

A voltmeter reading alone is not a reliable test of whether the cell can supply sustained current.

Part (b): Explain C’s different voltage.

The standard potential for the iron-silver cell is:

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=(+0.80)-(-0.44)\\ &=+1.24\ \mathrm{V} \end{aligned} \]

But the standard value is not necessarily the actual voltage.

Reducing silver-ion concentration makes the reduction of silver ions less favourable relative to the standard reference conditions.

With the other relevant conditions held fixed, the silver electrode’s reduction potential decreases. The cell potential consequently decreases.

Cell C’s lower open-circuit voltage is therefore consistent with its lower silver-ion concentration.

This does not prove that the bridge has greater resistance or is defective.

Part (c): Can we compare the currents?

Not from the given open-circuit readings alone.

Current depends on the connected resistance, internal resistance, and electrode behaviour under load.

A higher open-circuit voltage does not, by itself, provide enough information to calculate or guarantee a higher operating current in these different solutions.

Part (d): Reverse the voltmeter leads.

If the initial reading of C was \(+1.10\ \mathrm{V}\), it would become approximately \(-1.10\ \mathrm{V}\) when measured under otherwise unchanged open-circuit conditions.

The chemistry does not reverse.

Iron remains the anode, and silver remains the cathode under the stated conditions.

When current flows, nitrate still migrates towards iron and potassium towards silver.

The key distinction is between three things: the sign chosen by the measuring instrument, the electrochemical reaction direction, and the ability of the internal circuit to sustain ionic current.

Question 5

Extension challenge: A concentration cell changes direction without changing its electrodes.

Two copper electrodes are connected by a potassium nitrate salt bridge.

Initially:

  • The left beaker contains \(40.0\ \mathrm{mL}\) of \(0.500\ \mathrm{mol\,L^{-1}}\) copper sulfate.
  • The right beaker contains \(160.0\ \mathrm{mL}\) of \(0.250\ \mathrm{mol\,L^{-1}}\) copper sulfate.

Both electrodes are pure copper.

At \(25^\circ\mathrm{C}\), the cell is connected through a resistor and allowed to discharge spontaneously until there is no longer a concentration difference driving current.

Then an external power supply forces an additional \(386\ \mathrm{C}\) through the cell in the same chemical reaction direction as the original discharge.

The power supply is subsequently removed, and the two copper electrodes are reconnected through the resistor.

Assume:

  • Copper oxidation and copper-ion reduction are the only electrode reactions.
  • Electrode reactions are 100% charge-efficient.
  • Solution volumes stay constant.
  • Direct mixing and copper-ion diffusion between beakers are negligible.
  • The direction of the concentration effect can be predicted from the stated concentrations, treating activities as proportional to concentrations.
  • Liquid junction potentials are negligible.

Use \(F=96\,500\ \mathrm{C\,mol^{-1}}\).

Answer all parts.

(a) Initially, which copper electrode is the anode, and which is the cathode? State the electron-flow and bridge-ion migration directions.

(b) Calculate the charge that can pass spontaneously before the concentrations become equal. Find that equal concentration.

(c) Calculate the concentrations after the external source forces the additional \(386\ \mathrm{C}\).

(d) After removing the source and reconnecting the resistor, identify the new spontaneous reaction direction and bridge-ion migration directions.

(e) Explain why the charge sign of the anode during externally forced operation differs from its sign during spontaneous galvanic operation, even though the oxidation reaction initially continues at the same physical electrode. Explain also why the standard cell potential remains zero throughout the experiment.

Two unequal CuSO₄ beakers, containing 40.0 mL of 0.500 mol L⁻¹ solution and 160.0 mL of 0.250 mol L⁻¹ solution, each hold a copper electrode. A KNO₃ salt bridge connects the beakers, and external wiring provides selectable resistor and DC-supply branches.
Schematic initial copper concentration cell: unequal CuSO₄ solutions share a KNO₃ salt bridge and a selectable external circuit.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 5

Initially the right copper electrode is the anode and the left is the cathode. The cell can transfer \(1544\ \mathrm{C}\) spontaneously before the concentrations equalise. Forcing another \(386\ \mathrm{C}\) reverses the concentration difference, so the spontaneous electron and bridge-ion directions reverse when the power supply is removed.

The critical insight is that neither the physical location of an electrode nor its metal identity fixes its role permanently. The reaction direction depends on the actual electrochemical conditions.

Part (a): Identify the initial reaction direction.

Both half-cells contain the same copper redox couple, but their concentrations differ.

The left solution is more concentrated:

\[ c_L=0.500\ \mathrm{mol\,L^{-1}} \]

The right is less concentrated:

\[ c_R=0.250\ \mathrm{mol\,L^{-1}} \]

In the ideal concentration-cell model, reduction occurs in the more concentrated half-cell.

Initially:

Left cathode:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

Right anode:

\[ \ce{Cu(s) -> Cu^2+(aq) + 2e^-} \]

Electrons flow from right to left through the external circuit.

Nitrate migrates towards the right anode, and potassium towards the left cathode.

Notice something surprising: the right beaker initially contains more total copper ions because its volume is much larger.

But the reaction direction depends on copper-ion concentration, not simply the total number of ions in the beaker.

Part (b): Find the point where the spontaneous current stops.

First calculate the initial amounts.

Left:

\[ \begin{aligned} n_L&=c_LV_L\\ &=0.500\times0.0400\\ &=0.0200\ \mathrm{mol} \end{aligned} \]

Right:

\[ \begin{aligned} n_R&=c_RV_R\\ &=0.250\times0.160\\ &=0.0400\ \mathrm{mol} \end{aligned} \]

Let \(x\) mol be the amount of copper ions reduced in the left beaker.

The same amount of copper ions is produced by oxidation in the right beaker.

Therefore:

  • Left amount becomes \(0.0200-x\) mol.
  • Right amount becomes \(0.0400+x\) mol.

At the point where the concentration difference disappears:

\[ \frac{0.0200-x}{0.0400} = \frac{0.0400+x}{0.160} \]

Rearrange:

\[ \begin{aligned} 4(0.0200-x)&=0.0400+x\\ 0.0800-4x&=0.0400+x\\ 5x&=0.0400\\ x&=0.00800\ \mathrm{mol} \end{aligned} \]

Each copper ion requires two electrons.

Thus:

\[ \begin{aligned} Q_{\mathrm{eq}}&=2Fx\\ &=2(96\,500)(0.00800)\\ &=1544\ \mathrm{C} \end{aligned} \]

The equal concentration is:

\[ \begin{aligned} c_{\mathrm{eq}} &=\frac{0.0200-0.00800}{0.0400}\\ &=0.300\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The right beaker gives the same concentration:

\[ \frac{0.0400+0.00800}{0.160} = 0.300\ \mathrm{mol\,L^{-1}} \]

At this point, there is no concentration difference to drive further spontaneous current under the stated assumptions.

It would be incorrect to allow the cell to continue discharging in the same direction without external energy. That would take the system beyond its spontaneous stopping point.

Part (c): Follow the externally forced reaction.

The power supply forces another \(386\ \mathrm{C}\) through the cell.

The amount of electrons transferred is:

\[ \begin{aligned} n(e^-)&=\frac{386}{96\,500}\\ &=0.00400\ \mathrm{mol} \end{aligned} \]

This corresponds to:

\[ \begin{aligned} n(\mathrm{Cu}^{2+}) &=\frac{0.00400}{2}\\ &=0.00200\ \mathrm{mol} \end{aligned} \]

The forced reaction continues consuming copper ions in the left beaker and producing them in the right.

New left concentration:

\[ \begin{aligned} c_L &=\frac{0.0120-0.00200}{0.0400}\\ &=0.250\ \mathrm{mol\,L^{-1}} \end{aligned} \]

New right concentration:

\[ \begin{aligned} c_R &=\frac{0.0480+0.00200}{0.160}\\ &=0.3125\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The concentration difference has now reversed.

Part (d): Predict what happens when the power supply is removed.

The right beaker is now more concentrated.

Therefore, under spontaneous galvanic operation:

  • Right electrode: cathode, where copper ions are reduced.
  • Left electrode: anode, where copper is oxidised.
  • Electrons: flow from left to right.
  • Nitrate: migrates towards the left anode.
  • Potassium: migrates towards the right cathode.

These directions are the reverse of those during the original spontaneous discharge.

The cell hasn’t acquired a new electrode material. Its chemical conditions have changed enough to reverse its preferred reaction direction.

Part (e): Resolve the electrode-sign and standard-potential paradoxes.

During the initial spontaneous galvanic phase, the right electrode is the anode and is negative relative to the left cathode.

Once the concentrations become equal, the cell cannot spontaneously continue that reaction.

The external power supply then drives the same chemical direction beyond equilibrium.

During this externally forced, electrolytic phase:

  • The right electrode still undergoes oxidation and is therefore still the anode.
  • The left electrode still undergoes reduction and is therefore still the cathode.
  • But the power supply makes the right anode positive and the left cathode negative.

So anode means oxidation in both types of cell, but the electrode polarity differs between spontaneous galvanic operation and externally driven electrolytic operation.

The bridge-ion directions during the forced interval remain nitrate towards the right anode and potassium towards the left cathode because the imposed electrode reactions still create the same charge-balance requirements.

After removing the source, the spontaneous reactions reverse. The left electrode becomes the negative galvanic anode, while the right becomes the positive galvanic cathode.

Three stages of a copper concentration cell. Initially, the right-hand electrode is the negative anode and the left-hand electrode is the positive cathode, with electrons flowing right to left. An external DC supply then drives the same electrode reactions after concentration equalisation, making the right anode positive and the left cathode negative. After source removal, spontaneous electron flow and salt-bridge ion migration reverse, with the left electrode becoming the anode and the right electrode the cathode.
Schematic Cu²⁺ particles show changing solution concentrations; potassium and nitrate migration reverse when the cell’s spontaneous reaction reverses.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Finally, why is the standard cell potential always zero?

Both electrodes use the same standard reduction potential:

\[ E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{Cu^{2+}/Cu}} - E^\circ_{\mathrm{Cu^{2+}/Cu}} =0\ \mathrm{V} \]

That standard reference value doesn’t change.

What changes is the actual potential under non-standard conditions. When the concentration difference is present, it provides a driving force. When the concentrations become equal, that driving force disappears. After the external supply reverses the concentration difference, the preferred spontaneous reaction reverses as well.

The important lesson reaches beyond salt bridges: oxidation and reduction determine which ionic movements are needed, but the direction of the electrode reactions must be established from the actual cell conditions.

For a normal HSC galvanic-cell problem, the most reliable sequence is to identify the anode and cathode from the electrode reactions, determine where positive ions are being produced or consumed, and then assign bridge-ion migration. When the solutions are non-standard, determine whether the actual conditions could change those electrode roles before applying the rule.