Why Electrons Do Not Travel Through the Salt Bridge

A zinc-copper galvanic cell is connected to an ammeter. Electrons leave the zinc electrode, travel through a metal wire, and arrive at the copper electrode.

A zinc-copper galvanic cell is connected to an ammeter. Electrons leave the zinc electrode, travel through a metal wire, and arrive at the copper electrode. But the two solutions are connected by a salt bridge filled with potassium nitrate solution.

If an electric current needs a complete circuit, shouldn’t those electrons travel back through the salt bridge?

No. Electrons do not travel through the salt bridge because electrical charge is carried through the bridge by moving ions, not by free electrons. Electrons travel through the external metal circuit and are transferred during reactions at the electrode surfaces. Inside the salt bridge, positive and negative ions move to maintain charge balance.

The surprising part is that the current can be continuous even though the particles carrying it are different in different parts of the circuit.

Front view of a zinc-copper galvanic cell. Zinc and copper strips sit in separate beakers containing zinc sulfate and blue copper sulfate. An external metal wire connects them through an ammeter and resistor. A separate U-shaped potassium nitrate salt bridge connects the solutions. Coral arrows show electrons travelling through the wire from zinc to copper, while green nitrate ions and violet potassium ions travel through the salt bridge into their respective solutions.
Electrons travel through the external metal wire, while nitrate and potassium ions move through the salt bridge to maintain electrical charge balance in both solutions.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

01Where do the electrons actually go?

Follow an electron through a working zinc-copper galvanic cell.

At the zinc electrode, a zinc atom loses two electrons and enters the solution as a zinc ion:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e-} \]

This is oxidation. The zinc electrode is therefore the anode.

The electrons enter the metal electrode and travel through the external wire towards the copper electrode.

At the copper electrode, a copper ion in solution accepts two electrons and becomes solid copper:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

This is reduction. The copper electrode is therefore the cathode.

The electrons don’t continue into the salt bridge. They are transferred to copper ions at the copper electrode’s surface.

Two magnified metal-solution interfaces. At zinc, a surface atom leaves the lattice as Zn²⁺ while two electrons remain in the metal. At copper, a dissolved Cu²⁺ ion approaches the electrode, receives two electrons at the surface and becomes part of the copper lattice. Water molecules surround both interfaces.
Electrons stay in the metal and transfer only at the copper surface; dissolved ions, not free electrons, carry charge through solution.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

This gives us an important distinction.

LocationWhat carries charge?What happens?
Zinc electrodeElectrons in the metalZinc atoms release electrons during oxidation
External wireElectronsElectrons travel from zinc towards copper
Copper electrodeElectrons in the metalCopper ions accept electrons during reduction
Salt bridgeDissolved positive and negative ionsIons move to maintain charge balance
Electrolyte solutionsDissolved ionsIonic movement connects the electrode reactions to the bridge

The word current describes the rate at which electric charge moves. It does not mean the charge must be carried by electrons everywhere.

In the ordinary aqueous electrolytes used for HSC galvanic-cell questions, freely moving electrons are not the charge carriers in the liquid. Instead, dissolved ions provide the conducting particles.

The metal-solution interface is where the two forms of charge transport meet.

02How can ions replace electrons in the circuit?

Consider what happens to the two solutions as the electrodes react.

At the zinc anode, zinc atoms become \(\mathrm{Zn}^{2+}\) ions. Positive charge is being introduced into the zinc solution.

At the copper cathode, \(\mathrm{Cu}^{2+}\) ions become neutral copper atoms. Positive charge is being removed from the copper solution.

If nothing compensated for these changes, an electrical imbalance would quickly oppose further reaction.

The salt bridge provides the ionic pathway needed to prevent significant charge accumulation.

For a bridge containing potassium nitrate, \(\ce{KNO3}\):

  • Nitrate ions, \(\ce{NO3-}\), migrate towards the zinc half-cell, where positive ions are being produced.
  • Potassium ions, \(\mathrm{K}^{+}\), migrate towards the copper half-cell, where positive ions are being consumed.

Both movements help the cell maintain approximate electrical neutrality.

Cutaway of a U-shaped potassium nitrate salt bridge connecting zinc and copper solutions. K⁺ ions move towards copper, NO₃⁻ ions move towards zinc, and conventional ionic current flows towards copper.
Potassium and nitrate ions travel in opposite directions, yet both contribute to conventional ionic current from the zinc half-cell towards the copper half-cell.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Why do ions moving in opposite directions produce one current?

This is the part that often feels contradictory.

A positive ion moving right carries positive charge right.

A negative ion moving left also contributes to a conventional current directed right, because moving negative charge left is electrically equivalent to moving positive charge right.

So both potassium and nitrate ions contribute to the same direction of conventional current through the bridge.

In the normal zinc-copper galvanic cell:

  • Electrons move from zinc to copper through the external wire.
  • Conventional current in that wire is directed from copper to zinc.
  • Conventional ionic current through the bridge is directed from the zinc side towards the copper side.

Together, these form a continuous electrical circuit.

It’s rather like a relay race: different runners cover different sections, but the race continues.

Here, the different runners represent electrons in the metal and ions in the solution. The analogy stops at the handover. There isn’t a physical baton travelling around the entire circuit, and the same charged particle does not complete a full lap.

There is also a limitation to the simple ion-direction picture. Real ions undergo diffusion because of concentration differences as well as migration in response to electric fields. The arrows above describe the expected migration directions, not every individual ion’s motion.

03An experiment to distinguish ionic conduction from electron conduction

How could we test the idea that ions, rather than electrons, carry charge through the salt bridge?

Imagine designing an investigation using two identical zinc-copper cells.

The first apparatus: measure the working current

In each cell:

  1. Place a zinc strip in a beaker containing \(\ce{ZnSO4(aq)}\).
  2. Place a copper strip in a separate beaker containing \(\ce{CuSO4(aq)}\).
  3. Connect the metal strips through an external switch, resistor, and ammeter.
  4. Connect the solutions using a U-shaped tube filled with potassium nitrate solution held in agar gel.

The agar helps reduce bulk mixing between the solutions while allowing dissolved ions to move.

When the switch is closed, the galvanic cell can sustain an electric current while its reactions remain favourable and reactants are available.

But this experiment has a limitation.

An ammeter measures current in the external wire. It does not identify which particles carry charge inside the bridge.

The observation is consistent with ionic conduction, but a current reading alone is not a direct measurement of ion movement.

The revised apparatus: change what can move inside the bridge

Keep the electrodes, concentrations, resistor, and bridge geometry the same.

This time, compare two bridges:

  • Bridge A contains agar gel with dissolved \(\ce{KNO3}\).
  • Bridge B contains agar gel made with deionised water but no deliberately added electrolyte.
Two matched zinc–copper galvanic cells with identical beakers, electrodes and closed external circuits. One U-shaped agar bridge contains KNO₃; the other contains agar without added salt.
Only the bridge electrolyte changes: both cells share identical Zn/Cu half-cells and external circuits, while unsalted gel may still contain trace ions.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Predict the result.

Would the two cells produce similar sustained currents simply because both U-tubes contain wet gel?

No. Bridge A contains abundant mobile ions, so it should conduct ionic current much more effectively. Bridge B initially has far fewer mobile ions and should generally have a much larger resistance.

The comparison separates the presence of a wet connection from the presence of an effective ionic conductor.

Here is the expected qualitative pattern. These are predictions from the electrochemical model, not measurements from an experiment performed for this article.

ArrangementExpected electrical behaviourWhat it tells us
\(\ce{KNO3}\) bridge, switch closed, resistor connectedSustained current while conditions permitThe complete cell supports charge transport
Agar bridge without added salt, same resistorMuch smaller sustained current initiallyMobile ions are important for conduction
\(\ce{KNO3}\) bridge, switch open, high-resistance voltmeter connectedA voltage may be measured with negligible currentVoltage does not require substantial ongoing current
\(\ce{KNO3}\) bridge, switch closed, voltmeter leads reversedVoltage reading changes signMeter polarity does not change the chemical reaction

There are two experimental complications worth recognising.

First, the unsalted agar is not a perfect electrical insulator. It can contain small amounts of ions, and ions from the half-cell solutions can gradually diffuse into it. You should predict a much higher resistance, not necessarily a permanently zero current.

Second, this comparison still does not directly identify individual ions. A stronger investigation could analyse the solutions near each bridge end before and after current passes, and compare them with an open-circuit control.

For example, an increase in potassium transport towards the copper half-cell and nitrate transport towards the zinc half-cell, beyond the changes observed in the control, would support the proposed ionic-migration mechanism.

The open-circuit control matters because diffusion can occur even when no significant electrical current flows.

This is the distinction between testing a model and simply observing a working battery.

For a fuller explanation of why charge separation stops sustained current when the ionic connection is removed, see Why a Galvanic Cell Needs a Salt Bridge to Keep Current Flowing.

04What do electrode potentials tell us about the electron path?

Electrons move through the external wire because the two electrode reactions have different tendencies to gain or lose electrons.

Chemists represent these tendencies using reduction potentials.

A standard reduction potential, \(E^\circ\), is measured relative to a reference electrode, the standard hydrogen electrode, which is assigned a potential of \(0.00\ \mathrm{V}\).

The following rounded values are for \(25^\circ\mathrm{C}\).

Reduction half-equationStandard reduction potential
\(\ce{Zn^2+(aq) + 2e- -> Zn(s)}\)\(-0.76\ \mathrm{V}\)
\(\ce{Fe^2+(aq) + 2e- -> Fe(s)}\)\(-0.44\ \mathrm{V}\)
\(\ce{Cu^2+(aq) + 2e- -> Cu(s)}\)\(+0.34\ \mathrm{V}\)
\(\ce{Ag+(aq) + e- -> Ag(s)}\)\(+0.80\ \mathrm{V}\)

These are reference values, not measurements from our proposed investigation. See Purdue University’s electrochemistry reference for the zinc-copper values and standard-cell method.

For a spontaneous galvanic cell under standard conditions, the half-reaction with the more positive reduction potential occurs at the cathode.

To calculate the standard cell potential:

\[ E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{cathode}} - E^\circ_{\mathrm{anode}} \]

Here:

  • \(E^\circ_{\mathrm{cell}}\) is the standard cell potential, in volts (\(\mathrm{V}\)).
  • \(E^\circ_{\mathrm{cathode}}\) is the tabulated reduction potential for the cathode.
  • \(E^\circ_{\mathrm{anode}}\) is the tabulated reduction potential for the anode, still written as a reduction.

The subtraction uses reduction potentials for both electrodes. You don’t multiply these potentials when balancing the number of electrons.

Worked example: Why does the voltmeter show a negative reading?

An iron-copper galvanic cell uses an iron electrode in \(\ce{FeSO4(aq)}\), a copper electrode in \(\ce{CuSO4(aq)}\), and a potassium nitrate salt bridge.

The standard reduction potentials are \(-0.44\ \mathrm{V}\) for iron and \(+0.34\ \mathrm{V}\) for copper.

A high-resistance voltmeter has its red lead connected to iron and its black lead connected to copper.

Calculate the standard cell potential, predict the signed voltmeter reading under ideal standard conditions, and identify the electron path.

Step 1

Copper has the more positive standard reduction potential, so copper ions are reduced at the cathode.

Iron is oxidised at the anode:

\[ \ce{Fe(s) -> Fe^2+(aq) + 2e-} \]

The cathode reaction is:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

Step 2

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{cathode}} -E^\circ_{\mathrm{anode}}\\ &=(+0.34)-(-0.44)\\ &=+0.78\ \mathrm{V} \end{aligned} \]

The positive result indicates a spontaneous reaction in this direction under standard conditions.

Step 3

The copper electrode is positive relative to iron in this galvanic cell.

But the red lead is connected to iron, and the black lead is connected to copper.

The ideal voltmeter reading is therefore \(-0.78\ \mathrm{V}\), because a voltmeter displays the potential at its red lead minus the potential at its black lead.

Step 4

Electrons still move from iron towards copper through the external circuit when current is allowed to flow.

Nitrate ions migrate towards the iron half-cell, and potassium ions migrate towards the copper half-cell.

The negative voltmeter reading does not mean electrons travel backwards or through the salt bridge. It only reflects how the measuring instrument is connected.

Schematic iron–copper galvanic cell with an iron electrode in FeSO₄(aq) on the left and a copper electrode in CuSO₄(aq) on the right. A violet KNO₃ U-tube connects the solutions. A voltmeter above the apparatus has its red positive lead connected to iron and its black negative lead connected to copper.
The KNO₃ bridge connects the electrolytes, while separate red (+) and black (−) leads connect the voltmeter directly to iron and copper.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

05Standard cell potential is not the same as a loaded voltage

A standard reduction-potential table does not predict every voltage you will measure in a real laboratory cell.

At the usual reference temperature of \(25^\circ\mathrm{C}\), standard electrode conditions include pure solids, dissolved species at unit activity (often approximated in school calculations by \(1.0\ \mathrm{mol\,L^{-1}}\)), and gases at the standard pressure of \(1\ \mathrm{bar}\), where relevant.

Actual measurements may differ because the solution compositions are not standard, reactions become polarised, or resistance inside the cell produces a voltage loss when current flows.

A salt bridge also introduces a liquid junction between different solutions, which can contribute a small additional potential.

Three measurements must not be confused:

QuantityMeaning
\(E^\circ_{\mathrm{cell}}\)Cell potential calculated for standard conditions
Open-circuit voltagePotential difference measured while drawing negligible current
Loaded terminal voltagePotential difference measured while the cell supplies current to an external load

For example, a standard zinc-copper cell has a calculated \(E^\circ_{\mathrm{cell}}\) of \(+1.10\ \mathrm{V}\).

If a real cell supplies current through a resistor and its terminal voltage is only \(0.96\ \mathrm{V}\), that does not mean its salt bridge has started carrying electrons or that its standard potential has changed.

A loaded cell can lose voltage through internal resistance and electrode processes.

For more practice with the calculation itself, see How to Calculate Cell Potential from Reduction Potentials.

Worked example: How much charge does the bridge carry?

A zinc-copper galvanic cell is connected through a \(48.0\ \Omega\) resistor.

Its measured terminal voltage is \(0.960\ \mathrm{V}\) while the circuit is operating. Assume the voltage and current remain constant for \(120\ \mathrm{s}\).

Calculate:

  • The current through the external circuit.
  • The total charge transported through the circuit.
  • The mass of copper deposited at the copper cathode.
  • Whether the result tells us how many potassium ions crossed the salt bridge.

Use \(F=96\,500\ \mathrm{C\,mol^{-1}}\) and a copper molar mass of \(63.55\ \mathrm{g\,mol^{-1}}\).

Step 1

Using Ohm’s law for the external resistor:

\[ I=\frac{V}{R} \]

Here, \(I\) is current in amperes (\(\mathrm{A}\)), \(V\) is the voltage across the resistor in volts, and \(R\) is resistance in ohms (\(\Omega\)).

\[ \begin{aligned} I&=\frac{0.960\ \mathrm{V}}{48.0\ \Omega}\\ &=0.0200\ \mathrm{A} \end{aligned} \]

Step 2

Current is charge transferred per unit time, so:

\[ \begin{aligned} Q&=It\\ &=(0.0200)(120)\\ &=2.40\ \mathrm{C} \end{aligned} \]

Here, \(Q\) is electric charge in coulombs (\(\mathrm{C}\)), and \(t\) is time in seconds.

The charge transported through the external wire is \(2.40\ \mathrm{C}\).

In a steady circuit, the ionic current through the bridge has the same magnitude as the electronic current in the external circuit.

That means the bridge carries a net ionic charge transport corresponding to \(2.40\ \mathrm{C}\) during the same interval.

It does not mean \(2.40\ \mathrm{C}\) of electrons crossed the bridge.

Step 3

At the copper electrode:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

Two moles of electrons are needed to deposit one mole of copper.

The Faraday constant, \(F\), represents the magnitude of electric charge carried by one mole of electrons.

First calculate the amount of electrons:

\[ \begin{aligned} n(e^-)&=\frac{Q}{F}\\ &=\frac{2.40}{96\,500}\\ &=2.49\times10^{-5}\ \mathrm{mol} \end{aligned} \]

Since two electrons are required per copper ion:

\[ \begin{aligned} n(\ce{Cu}) &=\frac{2.49\times10^{-5}}{2}\\ &=1.24\times10^{-5}\ \mathrm{mol} \end{aligned} \]

Using \(m=nM\), where \(m\) is mass in grams and \(M\) is molar mass:

\[ \begin{aligned} m(\ce{Cu}) &=(1.24\times10^{-5})(63.55)\\ &=7.90\times10^{-4}\ \mathrm{g} \end{aligned} \]

Approximately \(0.790\ \mathrm{mg}\) of copper is deposited.

Step 4

The electron-transfer calculation determines the charge that passed through the external circuit and the copper produced by reduction.

It does not reveal the exact number of potassium ions or nitrate ions crossing the bridge.

Both ion types can contribute to the ionic current. Their individual contributions depend on their transport behaviour, which we have not measured.

The correct conclusion is that the salt bridge conducts the required electric current through ionic movement, without conducting electrons through the aqueous solution.

Zinc–copper galvanic cell with a 48.0 Ω resistor and ammeter in series, a voltmeter reading 0.960 V across the electrodes, and a U-shaped KNO₃ salt bridge showing separate electron and ion pathways over 120 seconds.
Electrons move through the external metal wire, while K⁺ and NO₃⁻ migrate through the salt bridge to maintain charge balance.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

06A useful diagnostic: what does each observation actually prove?

Before tackling harder questions, separate four ideas that often get mixed together.

ObservationSupported conclusionWhat you cannot conclude
A cell gives a positive voltmeter readingOne electrode has a higher measured potential than the other for the selected connectionsThat substantial current is flowing
An ammeter measures sustained currentThe complete circuit permits charge transportThat electrons must be the carriers everywhere
An inert salt bridge allows sustained operationIonic conduction and charge balance support the separated reactionsThat bridge ions are being reduced or oxidised
An unexpected solid forms near a bridge endSome additional chemical process may be occurringThat electrons travelled through the bridge

The final row is particularly important.

A bridge ion can move because of an electric field, diffuse because of a concentration gradient, or participate in an unwanted chemical reaction.

Those are different processes. Observing one does not automatically prove another.

07Questions and solutions

The first question checks the normal galvanic-cell model. The later questions test what happens when the experiment changes, when ion diffusion competes with migration, and when an unexpected reaction bypasses part of the electrical circuit.

Unless otherwise stated, assume aqueous solutions at \(25^\circ\mathrm{C}\), ideal electrical connections, and no side reactions beyond those specified. All measurements in these questions are illustrative, not reported experimental data.

Use \(F=96\,500\ \mathrm{C\,mol^{-1}}\) where required.

Question 1

A zinc electrode in \(\ce{ZnSO4(aq)}\) and a copper electrode in \(\ce{CuSO4(aq)}\) form a galvanic cell. The solutions are connected using a potassium nitrate salt bridge, and the metals are joined through an external resistor.

The standard reduction potentials are:

\[ \begin{aligned} E^\circ(\ce{Zn^2+/Zn})&=-0.76\ \mathrm{V}\\ E^\circ(\ce{Cu^2+/Cu})&=+0.34\ \mathrm{V} \end{aligned} \]

Identify the anode and cathode, write the electrode half-equations, state the directions of electron movement and salt-bridge ion migration, and calculate the standard cell potential.

Solution 1

The zinc electrode is the negative anode, the copper electrode is the positive cathode, electrons move from zinc to copper through the external wire, and the standard cell potential is \(+1.10\ \mathrm{V}\).

Copper has the more positive standard reduction potential, so copper ions undergo reduction at the cathode:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

Zinc undergoes oxidation at the anode:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e-} \]

The cell potential is:

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{cathode}} -E^\circ_{\mathrm{anode}}\\ &=(+0.34)-(-0.76)\\ &=+1.10\ \mathrm{V} \end{aligned} \]

During operation, nitrate ions migrate towards the zinc half-cell to compensate for the production of \(\mathrm{Zn}^{2+}\).

Potassium ions migrate towards the copper half-cell to compensate for the removal of \(\mathrm{Cu}^{2+}\).

A tempting mistake is to send nitrate ions towards copper simply because copper is the positive electrode. But the useful distinction is between the charge of the metal electrode and the changing charge balance in its surrounding solution.

The bridge ions respond to the electrochemical conditions in the solutions. They do not follow the external electron path.

Question 2

Two zinc-copper galvanic cells have identical electrodes, electrolyte concentrations, and initial chemical conditions.

Both use potassium nitrate bridges, but their shapes differ:

  • Cell A has a short, wide bridge with relatively low ionic resistance.
  • Cell B has a long, narrow bridge with relatively high ionic resistance.

Each cell is connected to an external \(25.0\ \Omega\) resistor.

The terminal voltages remain constant during a \(240\ \mathrm{s}\) test:

CellLoaded terminal voltage
A\(1.00\ \mathrm{V}\)
B\(0.500\ \mathrm{V}\)

Assume both cells have an open-circuit potential of \(1.10\ \mathrm{V}\) throughout the test, and model all internal losses as a single resistance.

Two side-by-side zinc–copper galvanic cells with identical electrodes, solution levels and 25.0 Ω external resistors. Cell A has a short, wide KNO₃ bridge and a loaded voltage of 1.00 V; Cell B has a long, narrow bridge and a loaded voltage of 0.500 V. Both are tested for 240 seconds.
Electrons move through the external metal circuit, while K⁺ and NO₃⁻ ions carry charge through the KNO₃ salt bridge.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Calculate the current and the total charge passed through the external circuit in each cell. Determine the effective internal resistance of each cell and the mass of zinc consumed through the external-current reaction.

Then evaluate this claim:

“The lower voltage of Cell B proves that fewer electrons can travel through its salt bridge, so Cell B must have a lower standard cell potential.”

Use \(M(\ce{Zn})=65.38\ \mathrm{g\,mol^{-1}}\).

Solution 2

Cell A carries \(0.0400\ \mathrm{A}\) and consumes approximately \(0.00325\ \mathrm{g}\) of zinc. Cell B carries \(0.0200\ \mathrm{A}\) and consumes approximately \(0.00163\ \mathrm{g}\). Their standard cell potentials remain the same; the different loaded voltages are consistent with different internal resistances, not different electron pathways through the bridges.

First calculate the currents using \(I=V/R\):

\[ \begin{aligned} I_A&=\frac{1.00}{25.0} =0.0400\ \mathrm{A}\\ I_B&=\frac{0.500}{25.0} =0.0200\ \mathrm{A} \end{aligned} \]

Next calculate the total charges, using \(Q=It\):

\[ \begin{aligned} Q_A&=(0.0400)(240)=9.60\ \mathrm{C}\\ Q_B&=(0.0200)(240)=4.80\ \mathrm{C} \end{aligned} \]

The effective internal resistance, \(r\), can be found from:

\[ E_{\mathrm{oc}}=V+Ir \]

Here, \(E_{\mathrm{oc}}\) is the open-circuit potential, \(V\) is the loaded terminal voltage, and \(I\) is current.

Rearranging:

\[ r=\frac{E_{\mathrm{oc}}-V}{I} \]

For Cell A:

\[ r_A=\frac{1.10-1.00}{0.0400} =2.50\ \Omega \]

For Cell B:

\[ r_B=\frac{1.10-0.500}{0.0200} =30.0\ \Omega \]

The longer, narrower bridge provides a less effective ionic conduction path. Under the stated model, this increases the cell’s internal resistance and reduces its current and loaded terminal voltage.

Now calculate zinc consumption.

At the zinc electrode:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e-} \]

Two moles of electrons correspond to one mole of zinc oxidised.

For Cell A:

\[ \begin{aligned} n_A(\ce{Zn}) &=\frac{9.60}{2(96\,500)}\\ &=4.97\times10^{-5}\ \mathrm{mol} \end{aligned} \]

Therefore:

\[ \begin{aligned} m_A(\ce{Zn}) &=(4.97\times10^{-5})(65.38)\\ &=0.00325\ \mathrm{g} \end{aligned} \]

Cell B carries half as much charge in the same time, so it consumes half as much zinc:

\[ m_B(\ce{Zn})=0.00163\ \mathrm{g} \]

The tempting interpretation is that Cell B conducts fewer electrons through its bridge.

That is incorrect. Neither bridge conducts the cell current through freely moving electrons in the aqueous electrolyte.

Cell B permits less ionic current under load. Because the reactions at the electrodes and the current through the external circuit are coupled, less ionic current means a smaller external electron current.

Both cells have the same standard reduction potentials and therefore the same calculated \(E^\circ_{\mathrm{cell}}=+1.10\ \mathrm{V}\).

The loaded voltages differ because of resistance. The calculation does not imply a change in the standard potential.

Question 3

An iron-silver galvanic cell contains:

  • An iron electrode in \(\ce{FeSO4(aq)}\), on the left.
  • A silver electrode in \(\ce{AgNO3(aq)}\), on the right.
  • A U-shaped salt bridge containing potassium chloride, \(\ce{KCl(aq)}\).

The electrodes are connected through a resistor.

The standard reduction potentials are:

\[ \begin{aligned} E^\circ(\ce{Fe^2+/Fe})&=-0.44\ \mathrm{V}\\ E^\circ(\ce{Ag+/Ag})&=+0.80\ \mathrm{V} \end{aligned} \]

After the cell has operated for some time, a white precipitate appears near the silver-side opening of the bridge.

An iron–silver galvanic cell with FeSO₄ and AgNO₃ solutions in separate beakers, connected by a U-shaped KCl gel bridge. A white cloudy precipitate surrounds the bridge's silver-side opening, and an external resistor connects the two metal electrodes.
The metal electrodes connect through the external resistor, while the salt bridge links the solutions and shows a white cloud at its silver-side mouth.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

A student argues:

“Chloride ions are negative, so they should migrate towards the iron anode. The precipitate near silver proves the ion-direction rule is wrong, or that electrons must have carried charge through the bridge.”

Explain why this argument fails.

Identify the precipitate, distinguish the relevant transport processes, calculate the initial standard cell potential, and explain why the standard value may not equal the later measured voltage.

Solution 3

The precipitate is silver chloride, \(\ce{AgCl(s)}\). Its formation near the silver half-cell does not contradict the predicted electrical migration of chloride towards iron, because diffusion and migration can act in different directions.

Initially, iron is the anode:

\[ \ce{Fe(s) -> Fe^2+(aq) + 2e-} \]

Silver is the cathode:

\[ \ce{Ag+(aq) + e- -> Ag(s)} \]

The standard cell potential is:

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=(+0.80)-(-0.44)\\ &=+1.24\ \mathrm{V} \end{aligned} \]

The positive result predicts the spontaneous iron-oxidation and silver-reduction reaction under standard conditions.

In this operating cell, chloride ions have an electrical migration tendency towards the iron half-cell, while potassium ions migrate towards silver.

However, chloride concentration is initially high inside the KCl bridge and very low in the silver nitrate solution.

This concentration difference drives chloride diffusion towards the silver-side opening.

When chloride meets silver ions, a precipitation reaction can occur:

\[ \ce{Ag+(aq) + Cl-(aq) -> AgCl(s)} \]

The precipitation consumes dissolved chloride near the boundary. That can maintain a concentration gradient favouring further chloride diffusion into the silver solution.

Magnified KCl salt-bridge tip immersed in AgNO₃ solution. Concentrated chloride ions diffuse out of the bridge and form white AgCl precipitate, while their electrical migration tendency points back towards the iron half-cell. Potassium ions migrate towards silver.
Ions carry charge through the bridge: chloride diffuses into silver solution and precipitates as AgCl despite its opposing electrical migration.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The key is that electrical migration and diffusion are not the same movement.

Migration responds to an electric field.

Diffusion responds to a concentration gradient.

The net movement of a particular ion depends on both effects, as well as any chemical reaction consuming it. Consequently, the total chloride movement near the silver-side boundary can differ from its electrical migration direction.

The chloride has not carried electrons through the bridge. It has moved as an ion and reacted with silver ions.

There is also a second consequence.

Precipitation removes \(\mathrm{Ag}^{+}\) from solution, changing the conditions at the silver electrode. The actual electrode potential can therefore change.

The calculated \(+1.24\ \mathrm{V}\) remains the standard cell potential for the stated iron-silver reaction, but it is not automatically the voltage after precipitation changes the solution.

Without additional information about the resulting ion activities and other losses, we cannot calculate the later measured voltage or confidently establish whether the original reaction direction remains favourable.

This is why an apparently suitable conducting salt can be a poor choice for a bridge: its ions may interfere chemically with the half-cells.

Question 4

A zinc-copper cell initially operates spontaneously as a galvanic cell under standard conditions.

Its standard cell potential is \(+1.10\ \mathrm{V}\).

An experimenter now connects an external DC power source so that its positive terminal is connected to the copper electrode and its negative terminal to the zinc electrode. The source opposes the cell’s original spontaneous current.

The total series resistance is \(20.0\ \Omega\).

Assume the cell remains at a reversible potential of \(1.10\ \mathrm{V}\), neglect overpotentials, and treat the total resistance as constant.

Two source voltages are tested separately:

  • Experiment A: \(1.30\ \mathrm{V}\).
  • Experiment B: \(0.900\ \mathrm{V}\).

A potassium nitrate bridge remains connected throughout.

Zinc and copper electrodes in separate beakers connected by a KNO₃ U-tube. An external ideal DC supply, set to either 1.30 V or 0.900 V, connects negative-to-zinc and positive-to-copper through a total series resistance of 20.0 Ω.
The KNO₃ bridge joins the two solutions, while the external circuit links the metal electrodes through an opposing DC source.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

For each source voltage:

  1. Determine the magnitude and direction of the net electrical current.
  2. Identify the anode and cathode.
  3. Write the electrode reactions.
  4. State the migration directions of \(\mathrm{K}^{+}\) and \(\ce{NO3-}\).
  5. Explain whether electrons need to pass through the salt bridge.

Solution 4

At \(1.30\ \mathrm{V}\), the external source drives the zinc-copper reaction backwards at \(0.0100\ \mathrm{A}\). At \(0.900\ \mathrm{V}\), the cell still operates in its original galvanic direction, also at \(0.0100\ \mathrm{A}\).

The important point is that the electrode reactions reverse when the imposed source overcomes the cell’s opposing potential. The salt bridge still carries ionic current, not electronic current.

Experiment A: source voltage \(1.30\ \mathrm{V}\)

The applied voltage exceeds the cell’s opposing potential.

The net driving voltage for the reverse reaction is:

\[ \begin{aligned} V_{\mathrm{net}}&=1.30-1.10\\ &=0.200\ \mathrm{V} \end{aligned} \]

Therefore:

\[ \begin{aligned} I_A&=\frac{0.200}{20.0}\\ &=0.0100\ \mathrm{A} \end{aligned} \]

The source forces electrons through the external circuit from the copper electrode towards the zinc electrode.

At zinc, reduction now occurs:

\[ \ce{Zn^2+(aq) + 2e- -> Zn(s)} \]

Zinc is now the cathode.

At copper, oxidation occurs:

\[ \ce{Cu(s) -> Cu^2+(aq) + 2e-} \]

Copper is now the anode.

The cell is operating electrolytically. The zinc cathode is negative, and the copper anode is positive.

Because zinc ions are being removed from solution, potassium ions migrate towards the zinc half-cell.

Because copper ions are being produced, nitrate ions migrate towards the copper half-cell.

Experiment B: source voltage \(0.900\ \mathrm{V}\)

The source opposes the original cell reaction, but its voltage is insufficient to reverse it.

The remaining net driving voltage is:

\[ \begin{aligned} V_{\mathrm{net}}&=1.10-0.900\\ &=0.200\ \mathrm{V} \end{aligned} \]

So:

\[ I_B=\frac{0.200}{20.0} =0.0100\ \mathrm{A} \]

The cell continues operating galvanically, with external electron flow from zinc towards copper.

Zinc remains the negative anode:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e-} \]

Copper remains the positive cathode:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

Nitrate ions migrate towards zinc, and potassium ions migrate towards copper.

The trap is assuming that the original labels anode and cathode must remain attached to the same metals.

Anode means oxidation. Cathode means reduction.

In Experiment A, the cell has been driven backwards, so those roles switch. In Experiment B, the chemical reaction is only opposed, not reversed.

Notice something more subtle: zinc remains connected to the negative side of the external source in both experiments, yet it is the cathode in Experiment A and the anode in Experiment B.

Electrode polarity alone therefore does not identify the reaction without knowing whether the cell is operating galvanically or electrolytically.

In both cases, electrons travel through the metal circuit. Reversing the cell reaction reverses the ionic-current direction through the bridge; it does not turn the bridge into an electron conductor.

Question 5

A zinc-copper galvanic cell operates through an external resistor.

An experimenter accidentally uses a copper sulfate solution, \(\ce{CuSO4(aq)}\), inside the salt bridge instead of an inert potassium nitrate solution.

The bridge contains enough dissolved copper(II) ions for some of them to diffuse into the zinc half-cell and reach the zinc metal surface.

After a period of operation, three observations are recorded:

ObservationIllustrative measurement
Total electric charge through the external wire\(193\ \mathrm{C}\)
Increase in mass of the copper electrode\(0.06355\ \mathrm{g}\)
Net decrease in mass of the zinc strip\(0.07453\ \mathrm{g}\)

The zinc strip has developed an adherent reddish copper-coloured coating.

Front-view schematic of a zinc-copper galvanic cell. Two glass half-cells are joined by a blue CuSO₄-filled U-shaped salt bridge. The left zinc electrode has a visible reddish copper coating, while the right copper electrode has a thicker deposit. External wires connect both electrodes through a resistor and ammeter. Labels show 193 C external charge, 0.07453 g net zinc-strip mass loss and 0.06355 g copper-electrode mass gain.
Schematic view: the CuSO₄ bridge connects the solutions ionically, while the ammeter measures charge through the separate external wire.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Assume:

  • The external-current reaction is the ordinary zinc-copper galvanic reaction.
  • Any copper(II) ions that reach the zinc metal may undergo direct displacement by zinc.
  • These are the only two redox processes occurring.
  • All copper deposited directly onto the zinc strip stays attached to it.
  • No solid material detaches, and no other corrosion or side reactions occur.

Use:

\[ \begin{aligned} M(\ce{Zn})&=65.38\ \mathrm{g\,mol^{-1}}\\ M(\ce{Cu})&=63.55\ \mathrm{g\,mol^{-1}} \end{aligned} \]

Determine whether the mass measurements can be explained by the external-current reaction alone.

If not, calculate the amount of additional local reaction and the mass of copper coating deposited directly onto the zinc strip.

Explain where the electrons involved in that additional reaction travel, why the external current measurement does not record them, and whether the local reaction could continue if the external switch were opened.

Finally, explain what this experiment reveals about the difference between ionic conduction and chemical contamination of a salt bridge.

Solution 5

The measurements cannot be explained by the external-current reaction alone. They are consistent with an additional \(0.00500\ \mathrm{mol}\) of direct displacement reaction occurring at the zinc surface, depositing \(0.31775\ \mathrm{g}\) of copper onto the zinc strip without sending the additional electrons through the external wire or the salt bridge.

The surprising result is that a substantial copper coating can form on zinc while the coated strip still loses mass overall.

Step 1: Determine the reaction accounted for by the external current.

The external circuit transported \(193\ \mathrm{C}\).

The corresponding amount of electrons is:

\[ \begin{aligned} n(e^-)&=\frac{Q}{F}\\ &=\frac{193}{96\,500}\\ &=0.00200\ \mathrm{mol} \end{aligned} \]

For the ordinary galvanic reaction:

\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]

Two moles of electrons are transferred for each mole of zinc oxidised and each mole of copper deposited.

The external-current reaction therefore consumes:

\[ n_{\mathrm{wire}}(\ce{Zn}) =\frac{0.00200}{2} =0.00100\ \mathrm{mol} \]

The expected zinc mass loss from this reaction is:

\[ \begin{aligned} m_{\mathrm{wire}}(\ce{Zn}) &=(0.00100)(65.38)\\ &=0.06538\ \mathrm{g} \end{aligned} \]

The corresponding mass of copper deposited at the copper electrode should be:

\[ \begin{aligned} m_{\mathrm{wire}}(\ce{Cu}) &=(0.00100)(63.55)\\ &=0.06355\ \mathrm{g} \end{aligned} \]

This agrees exactly with the stated mass gain of the copper electrode.

So the external-current reaction accounts for the copper electrode’s behaviour.

However, it predicts a zinc-strip mass loss of only \(0.06538\ \mathrm{g}\), not \(0.07453\ \mathrm{g}\).

Something else must be happening at zinc.

Step 2: Identify the additional reaction.

Copper(II) ions from the bridge can reach the zinc metal.

Zinc is capable of reducing copper(II) ions directly:

\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]

This is the same overall redox chemistry as the separated-cell reaction, but it occurs locally at the zinc surface.

The zinc atoms lose electrons, and nearby copper ions gain them.

There is no need for the electrons involved in this local reaction to travel through the external circuit. They are transferred within the local metal-solution reaction region, potentially through the conducting copper coating as it develops.

The red coating is therefore consistent with copper deposition on zinc, not just copper deposition at the separate copper cathode.

Step 3: Account for the unexpected mass change.

For every mole of direct displacement reaction:

  • One mole of zinc is lost from the strip.
  • One mole of copper is deposited onto the strip.

The mass lost is \(65.38\ \mathrm{g}\) per mole of reaction.

The mass gained is \(63.55\ \mathrm{g}\) per mole of reaction.

Thus, the coated zinc strip loses a net:

\[ 65.38-63.55 =1.83\ \mathrm{g} \]

for every mole of direct displacement reaction.

Let \(n_{\mathrm{local}}\) represent the amount of this additional reaction, in moles.

The extra net mass loss beyond that explained by the wire current is:

\[ \begin{aligned} \Delta m_{\mathrm{local}} &=0.07453-0.06538\\ &=0.00915\ \mathrm{g} \end{aligned} \]

Therefore:

\[ \begin{aligned} n_{\mathrm{local}} &=\frac{0.00915}{1.83}\\ &=0.00500\ \mathrm{mol} \end{aligned} \]

The local reaction consumes \(0.00500\ \mathrm{mol}\) of zinc and deposits the same amount of copper onto the zinc surface.

The copper coating has a mass of:

\[ \begin{aligned} m_{\mathrm{Cu,coat}} &=(0.00500)(63.55)\\ &=0.31775\ \mathrm{g} \end{aligned} \]

This is much larger than the extra net mass loss of \(0.00915\ \mathrm{g}\), because the additional zinc removed is almost replaced by an equal amount, in moles, of copper.

Step 4: Check the complete mass balance.

Zinc consumed through the external-current reaction:

\[ 0.06538\ \mathrm{g} \]

Zinc consumed by direct displacement:

\[ (0.00500)(65.38)=0.32690\ \mathrm{g} \]

Total zinc consumed:

\[ 0.06538+0.32690 =0.39228\ \mathrm{g} \]

Copper deposited onto the zinc strip:

\[ 0.31775\ \mathrm{g} \]

Therefore, the net mass loss of the coated zinc strip is:

\[ \begin{aligned} \Delta m_{\mathrm{Zn\,strip}} &=0.39228-0.31775\\ &=0.07453\ \mathrm{g} \end{aligned} \]

This matches the supplied observation.

All three measurements are therefore mutually consistent under the stated assumptions.

Step 5: Explain why the extra reaction does not appear in the external current.

The external current measures electron movement through the external conductor.

It accounts for the zinc oxidation coupled to copper reduction at the separate copper electrode.

But the additional copper ions reach the zinc metal itself.

When copper ions undergo direct displacement there, zinc oxidation and copper reduction occur at the same local surface.

For each zinc ion entering the surrounding solution, a copper(II) ion is removed. The ionic charge is balanced locally by the redox reaction, without requiring the additional electrons to flow through the external wire.

Magnified zinc electrode cross-section showing Cu²⁺ ions depositing as a reddish copper coating, Zn atoms becoming Zn²⁺ ions, and electrons transferring locally through the metal. An inset shows the separate galvanic pathway through an external wire to the copper electrode.
At zinc, Cu²⁺ is reduced by electrons moving locally through the metal; the separate galvanic reaction sends electrons through the external wire.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

If the external switch were opened, the ordinary separated-cell current would stop being sustained.

However, the local displacement reaction could continue as long as copper(II) ions could reach unreacted zinc and the reaction remained favourable.

A red copper coating could therefore continue to form on zinc even with no measurable current through the disconnected external wire.

That would not contradict the rule that electrons do not travel through an aqueous salt bridge.

The electrons for the local reaction are transferred at the zinc surface, where the reacting species meet.

Step 6: Evaluate the choice of bridge electrolyte.

Copper sulfate is unsuitable as an inert bridge electrolyte for this zinc-copper experiment because its copper(II) ions can participate directly in an unwanted redox reaction.

A bridge can carry ionic current and, at the same time, allow chemical species to contaminate the half-cells.

Those are separate properties.

Replacing the copper sulfate bridge with a suitable potassium nitrate bridge would remove the extra copper(II) ions supplied by the bridge itself. It would not make ion diffusion between the half-cells fundamentally impossible, but it would avoid deliberately introducing a reactive oxidising ion into the bridge.

The central lesson is broader than the usual statement that electrons follow the wire and ions follow the bridge.

An ammeter measures the electron transfer coupled to the external circuit, not necessarily every redox reaction occurring anywhere in the apparatus.

Once you understand that distinction, the next useful decision in analysing a galvanic cell is whether the two half-reactions are genuinely separated. If reactive ions can cross between the solutions, chemical changes may occur outside the intended external-current pathway, even when your electrode equations and standard cell-potential calculation are correct.