Why Doubling Generator Speed Doubles Frequency and Peak EMF

Learn why doubling a generator's rotation speed doubles its electrical frequency and peak induced EMF without changing maximum magnetic flux. Explore Faraday's law, coil geometry, slip rings versus split rings, worked calculations, and challenging HSC Physics questions.

Turn a generator coil twice as fast, and two things happen on an oscilloscope: the voltage peaks get taller, and the waves get closer together. But the magnetic field hasn’t become stronger, and the coil hasn’t grown any larger. So what’s actually changed?

Predict what happens to the magnetic flux through the coil. Does its maximum value double, or does the coil sweep through the same range of flux in half the time?

It’s the second one. For an ideal AC generator with one magnetic pole pair, doubling the constant rotation speed doubles both the frequency and the peak induced EMF. A generator producing 5 Hz and 8 V peak will produce 10 Hz and 16 V peak when its speed doubles, provided the coil, magnetic field, and geometry remain unchanged.

The two changes come from the same physical cause, but they measure different things:

  • Frequency tells us how often the coil completes its pattern of changing magnetic flux.
  • Peak electromotive force (EMF) tells us the greatest rate at which that magnetic flux changes.

01Testing rotation speed: why the first measurement can mislead you

Imagine investigating a simple generator using equipment found in a school physics laboratory.

The apparatus consists of a rectangular coil mounted on a vertical shaft between two magnetic poles. The north pole is on the left, the south pole is on the right, and the magnetic field points horizontally across the gap.

The shaft is perpendicular to the magnetic field. A variable-speed motor drives the shaft, so the coil rotates through the field.

Two electrical connections emerge from the coil:

  1. Each end of the rotating coil connects to its own continuous metal slip ring, insulated from the other ring.
  2. Two stationary carbon brushes press against the rings. Wires from the brushes lead to a measuring instrument.

The slip rings allow the rotating coil to remain electrically connected to the stationary circuit without twisting the wires.

The first attempt: measuring DC voltage

Suppose you initially connect a DC voltmeter across the brushes.

You run the generator at 5 revolutions per second, then increase the speed to 10 revolutions per second.

What should the voltmeter display?

For an ideal sinusoidal AC generator, the time-averaged voltage over complete cycles is zero at both speeds. The positive and negative half-cycles cancel.

A DC voltmeter responding to this average could therefore display approximately 0 V in both trials.

It would be tempting to conclude that increasing the rotation speed had no effect on the induced voltage.

That conclusion would be wrong. The measurement is hiding the alternating waveform.

The improved experiment: separate speed from voltage

Replace the DC voltmeter with a high-input-impedance oscilloscope.

Then add an optical tachometer. A reflective mark on the rotating shaft passes the tachometer sensor once per revolution, allowing the mechanical rotation speed to be measured independently of the electrical waveform.

Now the experiment can measure three quantities separately:

  • Shaft speed, in revolutions per second.
  • Oscilloscope waveform period, in seconds.
  • Peak induced voltage, in volts.

Keep the same magnetic field, coil, rotation axis, and electrical connections. Record the waveform only after the motor reaches a stable speed.

The oscilloscope should draw negligible current, so its voltage reading closely approximates the open-circuit induced EMF.

This is a proposed investigation, not a report of a historical experiment. The numerical results below are calculated predictions for an ideal generator, not invented laboratory observations.

To understand what the instruments should show, we need to examine the coil’s geometry.

02Why the magnetic flux stays the same size

Picture the rotating coil at four positions during one revolution.

At the starting position, the coil’s surface faces the magnetic field directly. The magnetic flux through it is greatest.

After a quarter-turn, the coil is edge-on to the field. Its magnetic flux is zero.

After another quarter-turn, the coil again faces the field directly, but its chosen surface normal points in the opposite direction. The flux is now at its greatest negative value.

The remaining half-turn takes the coil back to its original orientation.

From the coil’s angle to magnetic flux

Magnetic flux measures how much magnetic field passes through a surface, taking its orientation into account.

For a uniform magnetic field,

\[ \Phi=BA\cos\theta \]

where:

  • \(\Phi\) is the signed magnetic flux through one turn, in webers (Wb).
  • \(B\) is magnetic flux density, in tesla (T).
  • \(A\) is the area enclosed by one turn, in square metres (\(\mathrm{m^2}\)).
  • \(\theta\) is the angle between the magnetic field and the coil’s area normal, measured in radians when used in calculations.

The area normal is an imaginary arrow perpendicular to the coil’s surface. We choose its direction to define positive flux.

The greatest flux magnitude is

\[ \Phi_{\max}=BA \]

Notice what’s missing from this equation: rotation speed.

Turning the coil faster doesn’t change \(B\), \(A\), or the largest possible alignment of its surface with the field.

The maximum magnetic flux therefore remains unchanged.

From changing flux to induced EMF

The missing ingredient is time.

Faraday’s law states that the induced EMF depends on the rate of change of magnetic flux linkage:

\[ \mathcal E=-\frac{d(N\Phi)}{dt} \]

Here:

  • \(\mathcal E\) is instantaneous induced EMF, in volts (V).
  • \(N\) is the number of turns in the coil.
  • \(t\) is time, in seconds (s).
  • \(N\Phi\) is the magnetic flux linkage of the coil.
  • The negative sign expresses Lenz’s law: the induced EMF acts in a direction that opposes the change in flux responsible for it.

One volt is equivalent to one weber per second.

We can write the flux linkage as \(\Lambda=N\Phi\). The symbol \(\Lambda\) will be useful when we compare an entire flux sweep with the time taken to complete it.

At constant angular speed,

\[ \theta=\omega t \]

where \(\omega\) is the angular speed, in radians per second (\(\mathrm{rad\,s^{-1}}\)). We have chosen \(t=0\) at maximum positive flux.

Substituting the rotation angle into the flux equation gives

\[ \Phi(t)=BA\cos(\omega t) \]

Applying Faraday’s law gives

\[ \mathcal E(t)=NBA\omega\sin(\omega t) \]

We’ve chosen the terminal polarity so that the EMF is positive during the first quarter-turn, while positive flux is decreasing.

The equation explains both the waveform shape and its maximum value.

The maximum magnitude occurs when the sine factor has magnitude 1:

\[ \mathcal E_{\text{peak}}=NBA\omega \]

Unlike maximum flux, peak EMF is directly proportional to angular speed.

Why maximum flux gives zero EMF

At the instant the coil has maximum positive flux, the flux is momentarily neither increasing nor decreasing.

Its rate of change is zero, so the induced EMF is zero.

One-quarter of a revolution later, the flux passes through zero. This is where its magnitude is changing most rapidly, giving the greatest EMF magnitude.

That distinction is essential:

The generator responds to how quickly flux changes, not simply how much flux is present.

03Why doubling angular speed doubles frequency

Angular speed and frequency describe the same rotation using different units.

A complete revolution corresponds to \(2\pi\) radians.

For constant rotation speed,

\[ \omega=2\pi f \]

Here \(f\) is the number of revolutions per second, measured in hertz (Hz).

For this single-pole-pair generator, one revolution produces one complete cycle of alternating EMF. Its electrical frequency therefore equals its mechanical rotation frequency.

If angular speed doubles,

\[ \omega_2=2\omega_1 \]

then frequency also doubles:

\[ f_2=2f_1 \]

The period \(T\), meaning the duration of one complete electrical cycle, is

\[ T=\frac{1}{f} \]

Consequently, doubling rotation speed halves the period.

Now return to the peak EMF equation:

\[ \mathcal E_{\text{peak}}=NBA\omega \]

If \(N\), \(B\), and \(A\) remain constant,

\[ \mathcal E_{\text{peak},2} =2\mathcal E_{\text{peak},1} \]

That’s the complete mathematical reason for the two changes.

Frequency doubles because the magnetic flux pattern repeats twice as often. Peak EMF doubles because that same flux pattern changes twice as quickly.

For a refresher on converting revolutions into radians and understanding angular speed, see Angular Velocity in HSC Physics: From Rotation to Linear Speed.

Worked example: One coil, two oscilloscope traces

An 80-turn rectangular coil rotates in a uniform magnetic field of \(0.30\,\mathrm T\). Each turn encloses an area of \(0.010\,\mathrm{m^2}\).

The coil initially rotates at \(5.0\) revolutions per second. Its speed is then doubled to \(10.0\) revolutions per second.

Calculate the frequency, period, and peak induced EMF at both speeds. The generator uses slip rings, and the oscilloscope measures the open-circuit voltage.

Step 1

\[ \begin{aligned} \Lambda_{\max}&=NBA\\ &=80(0.30)(0.010)\\ &=0.240\,\mathrm{Wb} \end{aligned} \]

The number of turns is dimensionless, so flux linkage has the same SI unit as magnetic flux, although it is often described in weber-turns.

This value remains unchanged when the rotation speed doubles.

Step 2

\[ \begin{aligned} \omega_1&=2\pi(5.0)\\ &=31.4\,\mathrm{rad\,s^{-1}}\\ T_1&=\frac{1}{5.0}\\ &=0.200\,\mathrm s \end{aligned} \]

The initial electrical frequency is \(5.0\,\mathrm{Hz}\).

Step 3

\[ \begin{aligned} \mathcal E_{\text{peak},1} &=NBA\omega_1\\ &=0.240(31.4)\\ &=7.54\,\mathrm V \end{aligned} \]

Step 4

\[ \begin{aligned} \omega_2&=2\pi(10.0)\\ &=62.8\,\mathrm{rad\,s^{-1}}\\ T_2&=\frac{1}{10.0}\\ &=0.100\,\mathrm s \end{aligned} \]

The new frequency is \(10.0\,\mathrm{Hz}\).

The new peak EMF is

\[ \begin{aligned} \mathcal E_{\text{peak},2} &=0.240(62.8)\\ &=15.1\,\mathrm V \end{aligned} \]

Step 5

The faster generator produces twice as many complete cycles per second, and its peak EMF is twice as large.

If both trials begin at maximum positive flux, the first positive EMF peak occurs after one-quarter of a revolution:

  • Initially: \(0.200/4=0.0500\,\mathrm s\).
  • At double speed: \(0.100/4=0.0250\,\mathrm s\).

The peak appears earlier because the coil reaches the required orientation sooner.

Predicted experimental results

The following table summarises illustrative theoretical readings for this coil. These are not measured results.

QuantityFirst trialDouble-speed trial
Rotation speed5.0 rev/s10.0 rev/s
Angular speed31.4 rad/s62.8 rad/s
Maximum flux per turn3.0 mWb3.0 mWb
Electrical frequency5.0 Hz10.0 Hz
Waveform period0.200 s0.100 s
Peak induced EMF7.54 V15.1 V
Ideal average AC voltage0 V0 V

There are three useful checks.

First, the maximum flux per turn remains \(3.0\,\mathrm{mWb}\), because the field and coil geometry have not changed.

Second, the waveform period halves.

Third, the peak EMF doubles, even though the signed average voltage over a complete cycle is still zero.

The improved experiment can establish the relationship because it measures the shaft speed, waveform timing, and voltage amplitude independently.

04Why slip rings and split rings produce different readings

So far, we’ve assumed the generator uses slip rings.

The rings matter because the EMF generated inside the rotating coil is not necessarily the same waveform delivered to the external circuit.

Slip rings preserve the alternating waveform

Each coil end remains connected to the same external brush throughout a revolution.

When the induced EMF reverses direction after half a turn, the terminal voltage reverses too.

For ideal contacts and negligible load,

\[ V_{\text{slip}}(t)=E_0\sin(\omega t) \]

Here \(V_{\text{slip}}\) is the voltage across the external brushes, and \(E_0\) is the peak induced EMF.

The output alternates between positive and negative voltage.

A split-ring commutator reverses the connections

A split-ring commutator consists of two insulated semicircular metal segments, each attached to a different coil end.

As the shaft rotates, each stationary brush changes which segment it touches every half-turn.

Ideally, this switching occurs as the induced EMF passes through zero.

The commutator reverses the external connections just as the induced EMF reverses, keeping the external voltage at one polarity.

For an ideal unloaded generator,

\[ V_{\text{split}}(t)=E_0|\sin(\omega t)| \]

This produces pulsating DC rather than alternating positive and negative voltage.

The important distinction is that the commutator changes the external connections, not the rate at which magnetic flux changes inside the coil.

For one magnetic pole pair:

MeasurementSlip ringsSplit-ring commutator
Induced EMF inside coilAlternatingAlternating
External outputACPulsating DC
Alternating EMF cycles per shaft revolution11
Positive output peaks per shaft revolution12
Effect of doubling speed on peak magnitudeDoublesDoubles

A split-ring generator can therefore produce twice as many positive output pulses as shaft revolutions, even though the induced alternating EMF still completes only one cycle per revolution.

That is why counting positive peaks without recognising the contact arrangement can give a misleading frequency.

For a multi-pole generator, the number of magnetic pole pairs also matters. The distinction between shaft revolutions, electrical cycles, and output pulses is developed further in Electrical vs Mechanical Generator Frequency Explained.

05Another way to understand the doubling: the same flux change in less time

We can explain the effect of speed without starting with the sinusoidal EMF equation.

Consider the first quarter-turn of a coil.

It begins at maximum positive magnetic flux and finishes at zero flux.

At a fixed rotation speed, that flux change takes a certain amount of time.

If the coil rotates twice as fast, the same change takes half as long.

Faraday’s law tells us that the average EMF over an interval is

\[ \overline{\mathcal E} =-\frac{\Delta\Lambda}{\Delta t} \]

Here \(\overline{\mathcal E}\) is the signed average induced EMF, \(\Delta\Lambda\) is the change in flux linkage, and \(\Delta t\) is the duration of the interval.

Halving the time while keeping the same flux change doubles the average induced EMF over that interval.

But average EMF and peak EMF aren’t identical.

Worked example: Same flux change, half the time

A 100-turn generator coil has a maximum magnetic flux of \(2.0\,\mathrm{mWb}\) per turn.

It rotates steadily at \(4.0\) revolutions per second.

Calculate the average induced EMF during the first quarter-turn, from maximum positive flux to zero flux. Then calculate its peak instantaneous EMF.

Repeat both calculations when the rotation speed doubles to \(8.0\) revolutions per second.

Step 1

Convert the maximum flux to webers:

\[ 2.0\,\mathrm{mWb} =2.0\times10^{-3}\,\mathrm{Wb} \]

The coil begins at maximum positive flux and finishes at zero flux.

\[ \begin{aligned} \Delta\Lambda &=N(\Phi_f-\Phi_i)\\ &=100(0-0.0020)\\ &=-0.200\,\mathrm{Wb} \end{aligned} \]

The negative result means the positive flux linkage is decreasing.

Step 2

At \(4.0\) revolutions per second,

\[ T_1=\frac{1}{4.0}=0.250\,\mathrm s \]

The first quarter-turn takes

\[ \Delta t_1=\frac{0.250}{4} =0.0625\,\mathrm s \]

Step 3

Using Faraday’s law,

\[ \begin{aligned} \overline{\mathcal E}_1 &=-\frac{-0.200}{0.0625}\\ &=+3.20\,\mathrm V \end{aligned} \]

The average EMF is positive because the positive flux linkage is decreasing.

The angular speed is

\[ \omega_1=2\pi(4.0) =25.1\,\mathrm{rad\,s^{-1}} \]

Therefore,

\[ \begin{aligned} \mathcal E_{\text{peak},1} &=N\Phi_{\max}\omega_1\\ &=0.200(25.1)\\ &=5.03\,\mathrm V \end{aligned} \]

The peak EMF is greater than the quarter-turn average because the rate of flux change isn’t constant throughout the quarter-turn.

Step 4

At \(8.0\) revolutions per second,

\[ \begin{aligned} T_2&=\frac{1}{8.0}=0.125\,\mathrm s\\ \Delta t_2&=\frac{0.125}{4}\\ &=0.03125\,\mathrm s \end{aligned} \]

The same flux linkage change now takes half as long.

\[ \begin{aligned} \overline{\mathcal E}_2 &=-\frac{-0.200}{0.03125}\\ &=+6.40\,\mathrm V \end{aligned} \]

The new angular speed is \(50.3\,\mathrm{rad\,s^{-1}}\), so

\[ \begin{aligned} \mathcal E_{\text{peak},2} &=0.200(50.3)\\ &=10.1\,\mathrm V \end{aligned} \]

Both the quarter-turn average and the instantaneous peak have doubled.

However, they remain different measurements.

There’s a useful deeper relationship here.

Over any interval where the induced EMF has one sign, the area under its voltage-time graph equals the magnitude of the corresponding flux linkage change.

For the first quarter-turn in this example, that magnitude is \(0.200\,\mathrm{Wb}\), equivalent to \(0.200\,\mathrm{V\,s}\).

The faster generator makes a taller, narrower voltage pulse. The area remains unchanged because the coil still passes through the same magnetic orientations.

This gives us a second way to check calculations: if a coil makes the same flux sweep twice as quickly, its EMF-time graph must account for the same total flux change in half the time.

06When the simple doubling rule does not apply

The relationship

\[ \mathcal E_{\text{peak}}\propto\omega \]

assumes more than just a spinning coil.

It assumes a fixed magnetic field, fixed coil geometry, a suitable rotation axis, and constant angular speed.

There are three important limits.

The orientation of the rotation axis matters

Suppose the shaft is perpendicular to the magnetic field, as in our original generator.

The coil’s area normal swings towards and away from the field direction. Magnetic flux changes continuously, producing an EMF.

Now imagine rearranging the apparatus so the shaft is parallel to the magnetic field.

If the conventional rectangular coil rotates about a shaft lying in its plane, its area normal remains perpendicular to the magnetic field throughout the motion.

The flux through the coil is then always zero.

Even if you double the rotation speed, the induced EMF remains zero.

This is an important boundary case: rotation does not automatically produce electromagnetic induction.

There must be a change in magnetic flux.

Measured terminal voltage is not always the induced EMF

The ideal peak EMF equation describes what is generated inside the coil.

Once a circuit draws current, some of that EMF may be lost across the coil’s internal resistance.

For a simple generator supplying a purely resistive load, neglecting inductance and other losses,

\[ V_{\text{load,peak}} =\mathcal E_{\text{peak}} \frac{R}{R+r} \]

Here \(R\) is the external load resistance, \(r\) is the coil’s internal resistance, both in ohms (\(\Omega\)), and \(V_{\text{load,peak}}\) is the peak voltage across the load.

If the resistance values stay fixed, doubling induced peak EMF still doubles the load’s peak voltage in this simple model.

But if the load changes at the same time, the terminal voltage might not double.

You need to distinguish the induced EMF from the voltage actually delivered to a connected device.

Rotation may not be uniform

If the coil speeds up and slows down during each revolution, we cannot describe its motion using one constant angular speed.

The more general expression is

\[ \mathcal E(t) =NBA\omega(t)\sin\theta(t) \]

where \(\omega(t)=d\theta/dt\) is the instantaneous angular speed.

The EMF now depends on both the coil’s orientation and how fast it is moving at that particular instant.

A coil might move very quickly near a maximum-flux position, yet generate almost no EMF at that instant because the sine factor is close to zero.

The waveform also need not be sinusoidal in time.

These limitations become especially important when interpreting unexpected oscilloscope measurements.

07Questions and solutions

Assume a uniform magnetic field, ideal contacts, and one magnetic pole pair unless a question states otherwise. Use the positive EMF convention established earlier: positive EMF corresponds to decreasing positive flux linkage.

Question 1

An ideal slip-ring generator rotates steadily at \(3.0\) revolutions per second and produces a peak induced EMF of \(4.5\,\mathrm V\).

The same coil is then rotated at \(6.0\) revolutions per second, with the magnetic field and coil geometry unchanged.

Calculate the new:

(a) Electrical frequency.

(b) Waveform period.

(c) Peak induced EMF.

Solution 1

The new electrical frequency is \(6.0\,\mathrm{Hz}\), the period is \(0.167\,\mathrm s\), and the peak induced EMF is \(9.0\,\mathrm V\).

For a single-pole-pair slip-ring generator, one complete revolution produces one complete alternating EMF cycle.

Therefore,

\[ f_2=6.0\,\mathrm{Hz} \]

The period is

\[ \begin{aligned} T_2&=\frac{1}{f_2}\\ &=\frac{1}{6.0}\\ &=0.167\,\mathrm s \end{aligned} \]

The maximum induced EMF is proportional to angular speed when \(N\), \(B\), and \(A\) remain constant.

\[ \begin{aligned} \mathcal E_{\text{peak},2} &=4.5\left(\frac{6.0}{3.0}\right)\\ &=9.0\,\mathrm V \end{aligned} \]

The tempting misconception is that the magnetic flux must also double. It doesn’t.

The coil passes through the same flux range, but it does so twice as quickly.

Question 2

Two identical ideal slip-ring generators, A and B, operate in identical magnetic fields.

Both begin at \(t=0\) with maximum positive flux linkage and rotate in the same direction.

Generator A rotates steadily at \(5.0\) revolutions per second and produces an EMF of \(8.0\,\mathrm V\) peak.

Generator B rotates steadily at \(10.0\) revolutions per second.

At \(t=0.050\,\mathrm s\), an observer finds that A produces \(+8.0\,\mathrm V\), while B produces \(0\,\mathrm V\).

The observer argues that generator B must be generating less voltage despite rotating faster.

(a) Calculate generator B’s peak EMF.

(b) Show mathematically why the two instantaneous readings at \(0.050\,\mathrm s\) are different.

(c) Find the instantaneous EMF of each generator at \(t=0.025\,\mathrm s\).

(d) Explain what comparison would correctly test the relationship between rotation speed and peak EMF.

Solution 2

Generator B produces \(16.0\,\mathrm V\) peak, exactly twice generator A’s peak. The zero reading at \(0.050\,\mathrm s\) is not evidence of weaker induction; the two coils are at different orientations at that time.

(a) Peak EMF

With unchanged coil geometry and magnetic field,

\[ \begin{aligned} \mathcal E_{\text{peak},B} &=8.0\left(\frac{10.0}{5.0}\right)\\ &=16.0\,\mathrm V \end{aligned} \]

(b) EMF at 0.050 s

Generator A has angular speed

\[ \omega_A=2\pi(5.0)=10\pi \]

Generator B has angular speed

\[ \omega_B=2\pi(10.0)=20\pi \]

Both values are in radians per second.

Their EMF equations, with \(t\) in seconds, are

\[ \begin{aligned} \mathcal E_A(t)&=8.0\sin(10\pi t)\\ \mathcal E_B(t)&=16.0\sin(20\pi t) \end{aligned} \]

At \(t=0.050\,\mathrm s\),

\[ \begin{aligned} \mathcal E_A&=8.0\sin(\pi/2)\\ &=+8.0\,\mathrm V\\ \mathcal E_B&=16.0\sin(\pi)\\ &=0\,\mathrm V \end{aligned} \]

Generator A has completed a quarter-turn, reaching zero flux and maximum positive EMF.

Generator B has completed a half-turn, reaching maximum negative flux and zero EMF.

(c) EMF at 0.025 s

\[ \begin{aligned} \mathcal E_A &=8.0\sin(\pi/4)\\ &=+5.66\,\mathrm V \end{aligned} \]

For generator B,

\[ \begin{aligned} \mathcal E_B &=16.0\sin(\pi/2)\\ &=+16.0\,\mathrm V \end{aligned} \]

Generator B is now at its positive peak, while generator A has not yet reached its own peak.

(d) The correct comparison

Compare the maximum EMF magnitudes over complete cycles, not necessarily the voltages at the same elapsed time.

At the same elapsed time, the faster rotor has turned through a greater angle.

At the same rotor orientation, however, B’s instantaneous EMF magnitude is twice A’s, because its angular speed is twice as large.

The observer confused instantaneous voltage with peak voltage. The doubling rule concerns peak magnitude, not the voltage at every matching clock time.

Question 3

A school is comparing two electrical contact arrangements on the same ideal generator.

In Run X, the generator rotates at \(20.0\) revolutions per second and uses a split-ring commutator. The output has positive pulses with a peak of \(10.0\,\mathrm V\).

In Run Y, the motor speed doubles to \(40.0\) revolutions per second, but the split-ring commutator is replaced with two slip rings.

The coil and magnetic field remain unchanged.

For both runs, define \(t=0\) as the instant the coil has maximum positive flux.

(a) State the frequency of the alternating EMF induced inside the coil in each run.

(b) Calculate the peak terminal voltage in Run Y.

(c) Determine the time of the first positive output maximum in each run.

(d) During the first \(0.100\,\mathrm s\), how many positive output maxima are produced in each run? Explain why counting positive maxima alone could disguise the speed change.

(e) Describe the most important difference between the two terminal voltage waveforms.

Solution 3

Run X generates alternating EMF at \(20.0\,\mathrm{Hz}\), while Run Y generates it at \(40.0\,\mathrm{Hz}\). Surprisingly, both runs produce four positive output maxima during the first \(0.100\,\mathrm s\), even though the shaft speed has doubled.

(a) Induced EMF frequency

The generator has one magnetic pole pair, so each shaft revolution corresponds to one complete cycle of induced alternating EMF.

Therefore,

\[ f_X=20.0\,\mathrm{Hz} \]

and

\[ f_Y=40.0\,\mathrm{Hz} \]

Changing the contact arrangement does not change the frequency of the alternating EMF inside the coil.

(b) Peak terminal voltage

Doubling the angular speed doubles the induced peak EMF.

\[ \begin{aligned} V_{\text{peak},Y} &=10.0\left(\frac{40.0}{20.0}\right)\\ &=20.0\,\mathrm V \end{aligned} \]

We assume ideal, lossless contacts.

(c) First positive maximum

Both arrangements reach their first positive output maximum after a quarter-turn.

For Run X,

\[ \begin{aligned} t_X&=\frac{1}{4f_X}\\ &=\frac{1}{4(20.0)}\\ &=0.0125\,\mathrm s \end{aligned} \]

For Run Y,

\[ \begin{aligned} t_Y&=\frac{1}{4f_Y}\\ &=\frac{1}{4(40.0)}\\ &=0.00625\,\mathrm s \end{aligned} \]

The faster coil reaches the first maximum in half the time.

(d) Number of positive maxima

In Run X, the split-ring commutator produces two positive output pulses per revolution.

The pulse rate is

\[ 2(20.0)=40.0\text{ pulses/s} \]

Over \(0.100\,\mathrm s\), there are

\[ 40.0(0.100)=4 \]

positive maxima.

In Run Y, slip rings produce one positive maximum per full alternating EMF cycle.

The output frequency is \(40.0\,\mathrm{Hz}\), so there are also

\[ 40.0(0.100)=4 \]

positive maxima.

The peak spacing is \(0.0250\,\mathrm s\) in both traces.

This does not mean the two generators have the same electrical behaviour.

(e) Waveform comparison

Run X produces positive-only pulses because the commutator reverses the external connections every half-turn.

Run Y produces a positive-negative sinusoidal waveform. Between consecutive positive maxima, it has a negative half-cycle.

The trap is assuming that the number of positive peaks always equals the frequency of the alternating EMF inside the coil.

For a slip-ring generator, it does. For this ideal split-ring generator, the positive pulse rate is twice that frequency.

Question 4

A slip-ring generator has an internal resistance of \(2.0\,\Omega\). At \(5.0\) revolutions per second, its open-circuit peak induced EMF is \(9.0\,\mathrm V\).

In Run A, the generator is connected to an external \(4.0\,\Omega\) resistor.

In Run B, the motor speed doubles to \(10.0\) revolutions per second, and the external resistor is replaced with a \(1.0\,\Omega\) resistor.

Assume that:

  • The motor maintains the stated rotation speeds.
  • The magnetic field and coil geometry remain unchanged.
  • Coil inductance, brush losses, and magnetic field changes caused by the output current are negligible.
  • The generator and load are purely resistive, producing sinusoidal current and voltage.
  • All mechanical energy transferred into electrical energy goes into the external resistor or internal resistance.

(a) Calculate the peak voltage across the external resistor in each run.

(b) State the output frequency in each run.

(c) Calculate the average electrical power delivered to the external resistor in each run. For a sinusoidal voltage, use \(V_{\text{rms}}=V_{\text{peak}}/\sqrt{2}\).

(d) Determine the ratio of the average mechanical torque required in Run B to that required in Run A. Explain the result using Lenz’s law and energy conservation.

Solution 4

The peak voltage across the external resistor is \(6.0\,\mathrm V\) in both runs, even though the frequency doubles. The average power delivered to the external resistor rises from \(4.5\,\mathrm W\) to \(18\,\mathrm W\), and the ideal average opposing torque increases by a factor of four.

The apparent contradiction disappears when we distinguish internal induced EMF from terminal voltage.

(a) Peak load voltage

For a purely resistive circuit,

\[ V_{\text{peak}}=E_0\frac{R}{R+r} \]

where \(E_0\) is the internally generated peak EMF.

Run A has \(E_0=9.0\,\mathrm V\).

\[ \begin{aligned} V_{\text{peak},A} &=9.0\frac{4.0}{4.0+2.0}\\ &=6.0\,\mathrm V \end{aligned} \]

In Run B, the induced peak EMF doubles to \(18.0\,\mathrm V\).

\[ \begin{aligned} V_{\text{peak},B} &=18.0\frac{1.0}{1.0+2.0}\\ &=6.0\,\mathrm V \end{aligned} \]

The generated EMF has doubled, but the smaller external resistance receives a smaller fraction of it.

(b) Frequency

The electrical frequencies are

\[ f_A=5.0\,\mathrm{Hz} \]

and

\[ f_B=10.0\,\mathrm{Hz} \]

The load change does not alter the frequency because the motor maintains the stated speeds.

(c) Average power delivered to the load

For a resistor,

\[ P=\frac{V_{\text{rms}}^2}{R} \]

Using \(V_{\text{rms}}=V_{\text{peak}}/\sqrt2\),

\[ P=\frac{V_{\text{peak}}^2}{2R} \]

Run A:

\[ \begin{aligned} P_A&=\frac{6.0^2}{2(4.0)}\\ &=4.5\,\mathrm W \end{aligned} \]

Run B:

\[ \begin{aligned} P_B&=\frac{6.0^2}{2(1.0)}\\ &=18\,\mathrm W \end{aligned} \]

The average external power increases fourfold, despite identical terminal peak voltages.

(d) Average mechanical torque

We also need the power lost as heat inside the generator.

First calculate the peak current in each run:

\[ \begin{aligned} I_{\text{peak},A} &=\frac{9.0}{4.0+2.0}\\ &=1.5\,\mathrm A\\ I_{\text{peak},B} &=\frac{18.0}{1.0+2.0}\\ &=6.0\,\mathrm A \end{aligned} \]

The average resistive heating in the internal resistance is

\[ P_r=\frac{I_{\text{peak}}^2r}{2} \]

For Run A,

\[ \begin{aligned} P_{r,A}&=\frac{1.5^2(2.0)}{2}\\ &=2.25\,\mathrm W \end{aligned} \]

For Run B,

\[ \begin{aligned} P_{r,B}&=\frac{6.0^2(2.0)}{2}\\ &=36\,\mathrm W \end{aligned} \]

The total average mechanical power transferred into electrical energy is therefore

\[ \begin{aligned} P_{\text{mech},A} &=4.5+2.25\\ &=6.75\,\mathrm W\\ P_{\text{mech},B} &=18+36\\ &=54\,\mathrm W \end{aligned} \]

The mechanical input power has increased by a factor of eight.

Average mechanical power is related to average torque \(\tau\) and constant angular speed by

\[ P_{\text{mech}}=\tau\omega \]

Since the angular speed doubles,

\[ \begin{aligned} \frac{\tau_B}{\tau_A} &=\frac{54/6.75}{10.0/5.0}\\ &=\frac{8}{2}\\ &=4 \end{aligned} \]

The average mechanical torque required in Run B is four times that in Run A.

Lenz’s law explains the physical origin of this resistance to rotation.

As the generator supplies current, magnetic forces associated with that current oppose the motion driving the induction. The motor must perform additional mechanical work to maintain the increased speed and current.

The tempting assumption is that equal terminal voltage means equal generated EMF or equal power.

Neither follows when the connected resistance changes. The generator in Run B delivers considerably more electrical energy per second, even though the voltage across the external resistor has the same peak value.

Question 5

An ideal slip-ring generator has a coil whose magnetic flux linkage varies between

\[ \Lambda_{\max}=+0.120\,\mathrm{Wb} \]

and

\[ \Lambda_{\min}=-0.120\,\mathrm{Wb} \]

The generator initially rotates at a constant \(5.0\) revolutions per second.

A technician wants to double its average rotation rate to \(10.0\) revolutions per second.

Instead of rotating steadily, they propose varying the angular speed during each revolution.

Their argument is:

“The generator produces very little EMF near maximum and minimum flux. We can rotate the coil extremely quickly through those orientations, then slow down where the flux changes most rapidly. This should let us double the average rotation rate without increasing the peak induced EMF.”

Assume the coil completes each revolution in the same amount of time, rotates continuously in one direction, has finite angular speed, and experiences an unchanged magnetic field. Its flux linkage still varies as the cosine of its angular position, but its angle need not increase uniformly with time.

(a) Calculate the original peak EMF.

(b) Determine whether the technician can complete a revolution in \(0.100\,\mathrm s\) while keeping the induced EMF magnitude at or below the original peak.

(c) Find a lower bound on the peak EMF required for the proposed \(0.100\,\mathrm s\) revolution.

(d) Calculate the peak EMF for uniform rotation at \(10.0\) revolutions per second, and explain what this comparison reveals about non-uniform rotation.

You must justify your conclusions without assuming the non-uniform-speed output is sinusoidal.

Solution 5

The technician’s proposal is impossible. The original peak EMF is \(3.77\,\mathrm V\), but completing the same flux cycle in \(0.100\,\mathrm s\) requires a peak magnitude of at least \(4.80\,\mathrm V\), regardless of how the angular speed is distributed throughout the revolution.

The surprising constraint is not the local angular speed. It is the total amount of flux linkage change that must occur within the available time.

(a) Original peak EMF

At a constant \(5.0\) revolutions per second,

\[ \begin{aligned} \omega_0&=2\pi(5.0)\\ &=31.4\,\mathrm{rad\,s^{-1}} \end{aligned} \]

The maximum flux linkage magnitude is \(0.120\,\mathrm{Wb}\).

Therefore,

\[ \begin{aligned} \mathcal E_0&=\Lambda_{\max}\omega_0\\ &=0.120(31.4)\\ &=3.77\,\mathrm V \end{aligned} \]

The original induced EMF varies between approximately \(-3.77\,\mathrm V\) and \(+3.77\,\mathrm V\).

(b) Can the technician preserve this peak?

No.

Consider what happens to the flux linkage during one complete revolution.

During the first half-turn, it changes from \(+0.120\,\mathrm{Wb}\) to \(-0.120\,\mathrm{Wb}\).

The magnitude of that change is

\[ 0.120+0.120=0.240\,\mathrm{Wb} \]

During the second half-turn, it changes from \(-0.120\,\mathrm{Wb}\) back to \(+0.120\,\mathrm{Wb}\).

That is another \(0.240\,\mathrm{Wb}\).

The total absolute change during one revolution is therefore

\[ \begin{aligned} |\Delta\Lambda|_{\text{total}} &=0.240+0.240\\ &=0.480\,\mathrm{Wb} \end{aligned} \]

From Faraday’s law, the magnitude of the induced EMF is the rate at which the flux linkage changes.

The area under the graph of absolute EMF against time over one revolution must therefore equal this total absolute flux linkage change.

That area is fixed at \(0.480\,\mathrm{V\,s}\).

If the technician caps the EMF magnitude at \(3.77\,\mathrm V\), then even a hypothetical constant-magnitude EMF of \(3.77\,\mathrm V\) throughout the entire \(0.100\,\mathrm s\) could account for only

\[ 3.77(0.100)=0.377\,\mathrm{V\,s} \]

That is less than the required \(0.480\,\mathrm{V\,s}\).

So the proposed voltage cap cannot work.

The technician’s reasoning considered how the EMF behaves at particular orientations, but ignored the total flux change required over the full revolution.

(c) Minimum necessary peak magnitude

The average magnitude of the induced EMF must be

\[ \begin{aligned} \overline{|\mathcal E|} &=\frac{0.480}{0.100}\\ &=4.80\,\mathrm V \end{aligned} \]

The peak magnitude of any waveform cannot be smaller than its average magnitude.

Therefore,

\[ \mathcal E_{\text{peak}}\geq4.80\,\mathrm V \]

For a continuous, finite-speed rotation, the peak must actually exceed this lower bound.

Why?

At the maximum-flux and minimum-flux positions, the instantaneous induced EMF is zero for finite angular speed. The EMF magnitude cannot remain at \(4.80\,\mathrm V\) throughout the entire revolution.

It must rise above its average elsewhere to compensate.

We can also calculate the shortest theoretically possible revolution time under the original \(3.77\,\mathrm V\) peak cap.

\[ \begin{aligned} T_{\min} &\geq\frac{0.480}{3.77}\\ &\geq0.127\,\mathrm s \end{aligned} \]

This gives an upper bound on the average revolution rate of approximately

\[ f_{\max}\leq7.85\,\mathrm{rev/s} \]

The equality is only a mathematical lower-limit case; a smooth finite-speed rotation cannot maintain the required constant EMF magnitude through the flux extrema.

Either way, \(10.0\) revolutions per second is impossible under the original peak-voltage cap.

(d) Compare with uniform rotation

If the coil instead rotates steadily at \(10.0\) revolutions per second,

\[ \begin{aligned} \omega&=2\pi(10.0)\\ &=62.8\,\mathrm{rad\,s^{-1}} \end{aligned} \]

Its peak EMF is

\[ \begin{aligned} \mathcal E_{\text{peak}} &=0.120(62.8)\\ &=7.54\,\mathrm V \end{aligned} \]

The results are:

Rotation patternAverage rotation ratePeak EMF
Original constant speed5.0 rev/s3.77 V
Proposed variable speed10.0 rev/sMust exceed 4.80 V
Constant double speed10.0 rev/s7.54 V

The technician has recognised something real: non-uniform rotation can change the shape and peak of the EMF waveform.

In particular, rotating faster where the flux changes slowly with angle, and slower where it changes rapidly with angle, can reduce the peak compared with rotating uniformly at the same average rate.

But that freedom has a limit.

Every complete revolution still requires the flux linkage to travel from maximum positive to maximum negative and back again.

No clever timing can remove that total change.

There is one final distinction.

If the non-uniform rotation pattern repeats every revolution, the waveform repeats every \(0.100\,\mathrm s\), giving a fundamental repetition frequency of \(10.0\,\mathrm{Hz}\). However, its voltage-time shape need not be a sine wave and may contain higher-frequency components.

So the familiar result that doubling speed doubles both frequency and peak EMF is exact for the ideal constant-speed rotating-coil model. For variable-speed motion, the repeating cycle time and the maximum instantaneous flux derivative must be examined separately.

08The next useful check: where does the generated energy go?

Once you can predict a generator’s frequency and peak induced EMF, the next question is what happens when the generator supplies current to a circuit.

Faraday’s law predicts the induced EMF from the motion and changing flux. The connected circuit determines the current and the terminal voltage. Lenz’s law then tells you why generating that current creates an opposing electromagnetic torque.

That gives you a useful method for HSC generator questions: identify the coil’s changing magnetic flux first, determine its rate of change, check whether the measurement is internal EMF or external voltage, and only then consider the electrical load and mechanical energy required to drive it.