How to Find Transformer Turns Ratio from Measured Voltages

Learn how to calculate a transformer's turns ratio from measured AC voltages, choose reliable readings, and recognise when loading affects the result. Includes worked examples, experimental setups, and challenging HSC Physics questions with solutions.

A transformer gives 12.0 V at its output when nothing is connected, but only 10.2 V when a resistor is attached. Has its turns ratio changed? The coils haven’t gained or lost any turns, so something else must explain the lower reading. The challenge is working out which measured voltages reveal the winding ratio and which are affected by the circuit connected to the transformer.

To find the turns ratio of an ideal transformer, divide the measured secondary voltage by the measured primary voltage:

\[ \frac{N_s}{N_p}=\frac{V_s}{V_p} \]

Here, \(N_s\) and \(N_p\) are the numbers of secondary and primary turns, while \(V_s\) and \(V_p\) are their voltages in volts (V).

For a real transformer, use simultaneous AC voltage measurements with the secondary effectively unloaded. The resulting voltage ratio is an estimate of the actual turns ratio.

For example, if the primary measures 4.0 V and the secondary measures 12.0 V, the estimated secondary-to-primary turns ratio is \(3:1\). There are approximately three secondary turns for every primary turn.

The important word is measured. A number printed on the power supply isn’t necessarily the voltage reaching the primary winding.

01Measure the windings, not the power-supply dial

Imagine two coils wrapped around the same iron core.

The first coil receives alternating current from a power supply. That current produces a changing magnetic field inside the core. The changing magnetic flux then induces a voltage in the second coil.

Each turn of wire linked by the same changing magnetic flux has the same magnitude of induced electromotive force, or emf. A winding with more turns has a larger total induced voltage.

Predict what happens if one winding has three times as many turns as the other.

Under ideal conditions, its induced voltage is three times as large. If we double the primary voltage without changing the transformer, the secondary voltage should also double.

This is the physical reason voltage measurements can reveal the number of turns.

What makes the voltage ratio valid?

The exact transformer equation describes an ideal transformer. It assumes:

  • All the changing magnetic flux produced in the core links both windings.
  • The windings have negligible electrical resistance.
  • There are no energy losses in the magnetic core.
  • The transformer operates with a suitable changing input voltage, normally AC.

For the voltage measurements, we’ll use positive RMS voltage magnitudes. RMS means root mean square: the effective value of an alternating voltage. Both meters must report the same kind of voltage measurement.

We aren’t using signed instantaneous voltages or trying to determine the winding polarity from these readings.

A real transformer has winding resistance, magnetic flux leakage, and core losses. Its terminal voltages therefore don’t always follow the ideal equation exactly.

Under no-load conditions, the secondary draws very little current. Its terminal voltage is then usually close to its induced emf, making the voltage ratio a useful estimate of the turns ratio.

This distinction is especially important when investigating an unfamiliar transformer.

For the underlying relationship between magnetic induction, voltage, and turns, see Ideal Transformer Voltage and Turns Ratio for HSC Physics. Here, we’ll concentrate on extracting the ratio from measurements and deciding whether those measurements are trustworthy.

02How a two-voltmeter experiment reveals the turns ratio

Suppose we have a transformer with two unlabelled windings. We want to estimate how many turns one winding has relative to the other, without dismantling it.

We can investigate this using a low-voltage AC source and two voltmeters.

The first design: measure the output

Connect one winding to an isolated low-voltage AC source. Call this winding the primary.

Leave the second winding disconnected from any load and connect an AC voltmeter across its two terminals.

Suppose the power supply’s display says 4.0 V and the secondary voltmeter reads 12.0 V.

It is tempting to conclude immediately that the turns ratio is \(3:1\).

That conclusion depends on an untested assumption: the primary winding must actually be receiving 4.0 V.

A power supply’s output can change under load. Resistance in connecting leads can also produce a voltage drop.

The single secondary reading cannot establish the primary voltage.

The revised design: measure both voltages simultaneously

Keep the isolated AC supply connected to the primary.

Connect one AC voltmeter in parallel across the primary terminals. Connect a second AC voltmeter in parallel across the secondary terminals.

Leave the secondary otherwise open-circuit, meaning no external load is connected. A suitable high-input-resistance voltmeter draws negligible current, so it doesn’t significantly load the secondary.

Read both meters at the same time.

Why take simultaneous readings?

Because if the supply voltage changes while you move a single meter between the windings, you may accidentally compare voltages from two different operating conditions.

Illustrative results

Imagine the following results from the revised experiment. These are constructed teaching data, not a record of an experiment performed.

TrialMeasured primary voltage, \(V_p\)Measured secondary voltage, \(V_s\)\(V_s/V_p\)
A2.0 V6.0 V3.0
B4.0 V12.0 V3.0
C6.0 V18.0 V3.0

In every trial, the secondary voltage is three times the primary voltage.

Therefore,

\[ \frac{N_s}{N_p}\approx3.0 \]

The estimated secondary-to-primary turns ratio is \(3:1\).

Notice what the repeated measurements establish.

The secondary voltage changes when the primary voltage changes, but the ratio stays constant. This is consistent with the same winding arrangement operating according to the ideal transformer model.

The measurements reveal the relative number of turns, not the absolute number. A transformer with 100 primary turns and 300 secondary turns would have the same ideal voltage ratio as one with 400 primary turns and 1200 secondary turns.

Worked example: Finding the turns ratio from two readings

An isolated AC supply is connected to winding P of a transformer. With winding S unloaded, two voltmeters give simultaneous RMS readings of 3.60 V across P and 9.00 V across S.

Estimate the secondary-to-primary turns ratio. If P contains 160 turns, estimate the number of turns on S. Assume ideal behaviour for the calculation.

Step 1Identify the measured voltages.

Winding P receives the input, so it is the primary.

\[ V_p=3.60\text{ V} \]

\[ V_s=9.00\text{ V} \]

The secondary voltage is larger, so we should expect more secondary turns.

Step 2Calculate the voltage ratio.

\[ \begin{aligned} \frac{N_s}{N_p} &=\frac{V_s}{V_p}\\ &=\frac{9.00\text{ V}}{3.60\text{ V}}\\ &=2.50 \end{aligned} \]

The volts cancel, leaving a dimensionless ratio.

Therefore,

\[ N_s:N_p=2.50:1=5:2 \]

Step 3Find the secondary turns.

Since \(N_p=160\) turns,

\[ \begin{aligned} N_s&=2.50N_p\\ &=2.50(160)\\ &=400\text{ turns} \end{aligned} \]

The secondary contains an estimated 400 turns.

The result fits the observation: winding S produces 2.5 times the voltage of winding P, so it must have approximately 2.5 times as many turns.

For an actual transformer, the result would remain an estimate because the no-load terminal voltage ratio is not necessarily identical to the physical turns ratio.

03What changes when you connect a load?

Return to the original transformer, with an estimated turns ratio of \(3:1\).

With the secondary unloaded, the measurements are:

  • Primary voltage: 4.0 V
  • Secondary voltage: 12.0 V

Now connect a resistor across the secondary.

What should happen to the output voltage?

An ideal transformer supplied with an unchanged primary voltage would maintain the same secondary voltage. A real transformer may not.

Current flowing through the windings produces resistive voltage drops. Leakage flux and other non-ideal effects can also affect the terminal voltage.

The supply itself may also sag when the transformer draws more current.

These are different causes, and the two-voltmeter design helps us separate them.

The new loaded readings are:

\[ V_p=3.8\text{ V},\qquad V_s=10.2\text{ V} \]

Dividing these gives

\[ \frac{10.2}{3.8}\approx2.68 \]

But the transformer hasn’t suddenly acquired a turns ratio of \(2.68:1\).

We have calculated the loaded terminal-voltage ratio, not necessarily the winding turns ratio.

Two effects are happening together:

  1. The measured primary voltage has fallen from 4.0 V to 3.8 V.
  2. The loaded secondary terminal voltage is lower than the ideal value predicted from that new primary voltage.

The second effect is the one a simple ratio calculation can hide.

Worked example: Separating supply sag from transformer voltage drop

A transformer is tested with the same AC supply setting in two conditions.

ConditionPrimary RMS voltageSecondary RMS voltage
Secondary unloaded5.0 V15.0 V
31 Ω load connected4.6 V12.4 V

Estimate the turns ratio from the no-load test. Then determine how much of the output-voltage reduction is associated with the change in primary voltage and how much remains after accounting for that change.

Assume the no-load ratio is a good estimate of the turns ratio, and use the ideal voltage relationship as the reference.

Step 1Estimate the turns ratio using the no-load measurements.

\[ \begin{aligned} \frac{N_s}{N_p} &\approx\frac{15.0\text{ V}}{5.0\text{ V}}\\ &=3.0 \end{aligned} \]

The estimated turns ratio is \(3:1\).

Step 2Predict the secondary voltage for the new primary voltage.

The measured primary voltage has fallen to 4.6 V.

Using the ideal reference,

\[ \begin{aligned} V_{s,\text{ideal}} &=V_p\frac{N_s}{N_p}\\ &=(4.6\text{ V})(3.0)\\ &=13.8\text{ V} \end{aligned} \]

If the output followed the ideal relationship at this new input voltage, it would be 13.8 V.

Step 3Separate the two contributions to the voltage reduction.

The total decrease in output voltage is

\[ 15.0-12.4=2.6\text{ V} \]

The primary voltage fell by 0.4 V.

At a turns ratio of \(3:1\), this corresponds to an ideal secondary-voltage reduction of

\[ (0.4\text{ V})(3.0)=1.2\text{ V} \]

The remaining difference is

\[ 13.8-12.4=1.4\text{ V} \]

So the observed 2.6 V reduction can be separated into:

  • 1.2 V associated with the reduced primary voltage.
  • 1.4 V of additional secondary terminal-voltage shortfall relative to the ideal reference.

Step 4Calculate what the load actually receives.

The 31 Ω resistor has 12.4 V across it.

Using Ohm’s law,

\[ \begin{aligned} I_s&=\frac{V_s}{R}\\ &=\frac{12.4\text{ V}}{31\,\Omega}\\ &=0.40\text{ A} \end{aligned} \]

The resistor dissipates

\[ \begin{aligned} P_{\text{load}} &=V_sI_s\\ &=(12.4\text{ V})(0.40\text{ A})\\ &=4.96\text{ W} \end{aligned} \]

Here, \(R\) is the load resistance in ohms (\(\Omega\)), \(I_s\) is the secondary current in amperes (A), and \(P_{\text{load}}\) is the power delivered to the load in watts (W).

The load receives 4.96 W.

We cannot conclude that the 1.4 V shortfall is entirely due to copper resistance. The measurements don’t isolate winding resistance from leakage effects or other non-ideal behaviour.

Nor can we determine the transformer’s total power loss from these voltage readings alone.

That requires more information.

04Keep voltage ratios, current ratios, and resistive losses separate

Three equations often appear together in transformer questions, but they answer different questions.

RelationshipWhat it tells youWhen to use it
\(\dfrac{V_s}{V_p}=\dfrac{N_s}{N_p}\)Ideal voltage transformationInferring the turns ratio from suitable voltage measurements
\(\dfrac{I_s}{I_p}=\dfrac{N_p}{N_s}\)Ideal current transformationRelating currents through an ideal transformer
\(P_{\text{heat}}=I^2R\)Resistive heatingFinding power dissipated in a resistance

Here, \(I_p\) is the primary current, \(I_s\) is the secondary current, and \(P_{\text{heat}}\) is the heating power.

The first two equations describe ideal transformation. The third describes a resistive loss.

They shouldn’t be mixed without considering where the resistance is located.

Why the current ratio runs in the opposite direction

Suppose an ideal transformer triples the voltage.

It would be reasonable to ask whether the current also triples.

It doesn’t. If both voltage and current tripled, the output power would be nine times the input power, which would violate conservation of energy.

For an ideal transformer supplying a resistive load, input power equals output power:

\[ V_pI_p=V_sI_s \]

Therefore,

\[ \frac{I_s}{I_p}=\frac{V_p}{V_s} \]

A transformer that triples voltage reduces current to one-third of the primary current.

This power calculation uses RMS voltage and current for an ideal transformer with a resistive load. In a real AC circuit, current may not be in phase with voltage, so multiplying RMS voltage by RMS current does not always give real power.

Why a resistance changes the measured output voltage

Consider a simplified transformer model.

An ideal transformer produces a secondary induced emf, \(E_s\). A resistance \(r\) is placed in series between this ideal secondary and the external load resistance \(R_L\).

This resistance represents a specified resistive loss in the simplified model. We aren’t claiming it accounts for every loss in a real transformer.

For the ideal transformer inside this model,

\[ E_s=V_p\frac{N_s}{N_p} \]

But the measured terminal voltage across the load is

\[ V_s=E_s-I_sr \]

Here, \(E_s\) is the RMS induced secondary emf in volts, and \(r\) is the series resistance in ohms. We assume sinusoidal operation, an ideal transformer core, and purely resistive elements in this simplified circuit.

Some of the induced voltage is dropped across the internal resistor, leaving less across the load.

The heating power in that resistor is calculated separately:

\[ P_{\text{heat}}=I_s^2r \]

This gives us a useful rule:

A lower loaded voltage does not mean the turns ratio has fallen. It may mean that part of the induced voltage is being dropped inside the transformer or its connections.

The ideal transformer’s current relationship still applies to the ideal stage in this simplified circuit. A real transformer’s measured primary current also includes its excitation current, so that current relationship is not always exact for a physical transformer.

05Choosing the right voltage readings

Before calculating a turns ratio, identify what the voltmeters are actually measuring.

Available informationCan you infer the turns ratio?
Simultaneous no-load primary and secondary AC voltagesYes, approximately for a real transformer; exactly under ideal assumptions
Simultaneous loaded primary and secondary AC voltagesNot necessarily; terminal voltage drops may affect the result
Secondary voltage and the power-supply dial settingOnly if the actual primary voltage is known to equal that setting
One measured secondary voltage aloneNo; the primary voltage is missing
Steady DC primary and secondary readingsNo; steady DC does not produce continuous transformer induction
Primary peak voltage and secondary RMS voltageNot directly; convert to a consistent measurement type first

The useful decision process is simple:

  1. Identify which winding receives the input. That is the primary.
  2. Check that the excitation is AC and that the voltage readings use consistent units and measurement conventions.
  3. Prefer simultaneous measurements taken with the secondary effectively unloaded.
  4. Calculate \(V_s/V_p\) for a secondary-to-primary ratio, or \(V_p/V_s\) for a primary-to-secondary ratio.
  5. Check whether the direction of voltage transformation agrees with the reported turns ratio.

A voltage ratio larger than 1 means the secondary has more turns under the ideal model. A voltage ratio smaller than 1 means fewer.

For an actual measurement, report a sensible number of significant figures. A voltmeter displaying 12.0 V doesn’t establish an infinitely precise turns ratio.

06Questions and solutions

The following questions move from direct voltage measurements to situations where the instruments and circuit conditions themselves affect the answer.

All measurements and experimental scenarios are illustrative. Assume single-phase transformers and RMS voltage measurements unless a question states otherwise.

Question 1

An ideal transformer is supplied with AC. With its secondary winding unloaded, simultaneous measurements give:

  • Primary voltage: 2.50 V
  • Secondary voltage: 10.0 V

Calculate the secondary-to-primary turns ratio. State which winding has more turns and whether the transformer is step-up or step-down.

Solution 1

The secondary-to-primary turns ratio is \(4:1\). The secondary has four times as many turns as the primary, making this a step-up transformer.

For an ideal transformer,

\[ \frac{N_s}{N_p}=\frac{V_s}{V_p} \]

Substituting,

\[ \begin{aligned} \frac{N_s}{N_p} &=\frac{10.0\text{ V}}{2.50\text{ V}}\\ &=4.00 \end{aligned} \]

Therefore,

\[ N_s:N_p=4:1 \]

The secondary voltage is four times the primary voltage, consistent with four times as many secondary turns.

The tempting mistake is to report \(1:4\) after dividing the voltages in the opposite order.

That ratio would describe primary turns relative to secondary turns. Always keep the requested winding order consistent.

Question 2

A transformer is tested with its secondary unloaded.

The primary voltmeter is accurate, but the secondary voltmeter has an unknown constant positive reading offset.

Assume the transformer’s true no-load secondary voltage is proportional to its primary voltage.

The following measurements are recorded:

TrialPrimary voltageDisplayed secondary voltage
A2.0 V6.4 V
B5.0 V15.4 V
C8.0 V24.4 V

The secondary meter’s offset remains the same in every trial.

a. Determine the estimated secondary-to-primary turns ratio.

b. Calculate the secondary voltmeter’s offset.

c. Predict the actual secondary voltage and the displayed secondary reading when the primary is 3.0 V.

d. Explain why simply dividing 6.4 V by 2.0 V would give the wrong turns ratio.

Solution 2

The estimated turns ratio is \(3:1\), the secondary meter reads 0.4 V too high, and a 3.0 V primary input would produce 9.0 V at the secondary while the faulty meter displays 9.4 V.

The key is that a constant reading offset is added to the voltage. It doesn’t scale with the input voltage.

Let \(k=N_s/N_p\) be the estimated turns ratio and \(d\) be the meter offset in volts.

Then,

\[ V_{\text{display}}=kV_p+d \]

Using trials A and B,

\[ \begin{aligned} 6.4&=2.0k+d\\ 15.4&=5.0k+d \end{aligned} \]

Subtract the first equation from the second.

\[ \begin{aligned} 15.4-6.4&=(5.0-2.0)k\\ 9.0&=3.0k\\ k&=3.0 \end{aligned} \]

The estimated secondary-to-primary ratio is \(3:1\).

Now substitute \(k=3.0\) into trial A:

\[ \begin{aligned} 6.4&=(3.0)(2.0)+d\\ d&=0.4\text{ V} \end{aligned} \]

Trial C confirms the result:

\[ (3.0)(8.0)+0.4=24.4\text{ V} \]

For a primary voltage of 3.0 V, the actual secondary voltage is

\[ V_s=(3.0)(3.0\text{ V})=9.0\text{ V} \]

The faulty meter displays

\[ 9.0+0.4=9.4\text{ V} \]

Finally, consider the tempting calculation from trial A:

\[ \frac{6.4}{2.0}=3.2 \]

This produces an incorrect turns-ratio estimate because 6.4 V includes an additive measurement error.

The correct proportional relationship is between the actual winding voltages, not between the primary voltage and an offset meter reading.

A graph of the displayed secondary voltage against primary voltage would have a gradient of 3.0 but a vertical intercept of 0.4 V.

That intercept is the clue. The observed pattern is consistent with a constant meter offset rather than a transformer whose turns ratio changes between trials.

Question 3

An unfamiliar transformer has two windings, P and S.

In the first test, P is connected to a 5.0 V RMS sinusoidal AC supply. With S unloaded, the measured secondary voltage is 15.0 V RMS.

In a separate thought experiment, the AC source is replaced by a 5.0 V steady DC source. A DC-capable voltmeter connected across S briefly deflects when the source is switched on, then reads 0 V after the circuit has settled.

Finally, the original AC supply is restored, with the primary voltage maintained at 5.0 V, and a 30 Ω resistor is connected across S.

a. Estimate the turns ratio from the AC no-load test.

b. Explain the brief secondary response and the subsequent zero reading during the DC test.

c. Calculate the expected current through the 30 Ω resistor if the transformer is ideal.

d. Explain why the original no-load data are insufficient to predict the exact resistor current for a real transformer.

Solution 3

The AC test gives an estimated turns ratio of \(3:1\). The steady DC test cannot determine the turns ratio, and the ideal AC resistor current would be 0.50 A. A real loaded current cannot be determined uniquely from the supplied no-load voltages.

Part a: Calculate the turns ratio.

Using the no-load AC readings,

\[ \begin{aligned} \frac{N_s}{N_p} &\approx\frac{V_s}{V_p}\\ &=\frac{15.0\text{ V}}{5.0\text{ V}}\\ &=3.0 \end{aligned} \]

Therefore,

\[ N_s:N_p\approx3:1 \]

Part b: Explain the DC observations.

Faraday’s law relates induced emf to the rate of change of magnetic flux:

\[ \mathcal{E}=-N\frac{d\Phi}{dt} \]

Here, \(\mathcal{E}\) is the induced emf in volts, \(N\) is the number of turns, \(\Phi\) is the magnetic flux through each turn in webers (Wb), and \(t\) is time in seconds (s).

When the DC supply is switched on, the primary current and magnetic flux change during the transient. This changing flux can induce a brief voltage in S.

After the circuit settles, the flux is no longer changing in the ideal steady-state model.

Then,

\[ \frac{d\Phi}{dt}=0 \]

so the induced secondary emf is zero.

A zero steady DC secondary reading therefore does not imply that S has zero turns or is necessarily broken.

It tells us that a steady magnetic flux does not produce continuous induced emf.

This DC situation is a thought experiment, not a recommended practical transformer test. A real transformer connected to steady DC may draw excessive current because its winding resistance can be low.

Part c: Calculate the ideal AC load current.

Under ideal AC operation, the secondary voltage remains 15.0 V.

Using Ohm’s law,

\[ \begin{aligned} I_s&=\frac{V_s}{R}\\ &=\frac{15.0\text{ V}}{30\,\Omega}\\ &=0.50\text{ A} \end{aligned} \]

The ideal resistor current would be 0.50 A.

The corresponding resistor power would be

\[ \begin{aligned} P_{\text{load}} &=V_sI_s\\ &=(15.0\text{ V})(0.50\text{ A})\\ &=7.5\text{ W} \end{aligned} \]

Part d: Explain the real-transformer limitation.

The 15.0 V measurement was taken with S unloaded.

Connecting the resistor causes secondary current to flow. A real transformer can then develop internal voltage drops, so the loaded terminal voltage need not remain 15.0 V.

Without information about the winding resistance and other relevant non-ideal effects, we cannot predict the exact loaded secondary voltage or current.

The tempting reasoning is that the turns ratio is fixed, so the loaded voltage must also be fixed.

The turns ratio is indeed fixed. But the relationship between induced emf and measured terminal voltage changes when current flows through a non-ideal transformer.

Question 4

A transformer is represented by an ideal transformer followed by a single resistance in series with its secondary.

The ideal transformer has:

  • Secondary-to-primary turns ratio \(3:1\)
  • Primary RMS voltage 6.0 V

The secondary circuit contains:

  • Series resistance \(r=2.0\,\Omega\)
  • External load resistance \(R_L=10.0\,\Omega\)

Assume the primary voltage remains constant, the ideal transformer has no excitation current or magnetic losses, and the two secondary resistances account for all power dissipation.

a. Calculate the induced secondary emf before the series resistance.

b. Determine the secondary current and the measured load voltage.

c. Calculate the current drawn from the AC source.

d. Calculate the power dissipated in the series resistance and the power delivered to the load. Verify that energy is conserved.

e. Explain why dividing the measured load voltage by the primary voltage does not give the transformer’s actual turns ratio.

Solution 4

The ideal secondary emf is 18 V, the secondary current is 1.5 A, and the measured load voltage is 15 V. The source supplies 4.5 A, with 4.5 W dissipated in the series resistance and 22.5 W delivered to the load.

The crucial distinction is between the ideal transformer’s induced secondary emf and the terminal voltage measured after the series resistance.

Part a: Calculate the induced emf.

For the ideal transformer stage,

\[ \begin{aligned} E_s&=V_p\frac{N_s}{N_p}\\ &=(6.0\text{ V})(3.0)\\ &=18\text{ V} \end{aligned} \]

Part b: Calculate the current and load voltage.

The two resistances are in series.

Their total resistance is

\[ R_{\text{total}}=2.0+10.0=12.0\,\Omega \]

The secondary current is

\[ \begin{aligned} I_s&=\frac{E_s}{R_{\text{total}}}\\ &=\frac{18\text{ V}}{12.0\,\Omega}\\ &=1.5\text{ A} \end{aligned} \]

The load voltage is

\[ \begin{aligned} V_s&=I_sR_L\\ &=(1.5\text{ A})(10.0\,\Omega)\\ &=15\text{ V} \end{aligned} \]

The remaining 3.0 V is dropped across the series resistance:

\[ (1.5\text{ A})(2.0\,\Omega)=3.0\text{ V} \]

These voltages add correctly:

\[ 15+3=18\text{ V} \]

Part c: Calculate the input current.

For the ideal transformer stage,

\[ \frac{I_p}{I_s}=\frac{N_s}{N_p} \]

Therefore,

\[ \begin{aligned} I_p&=3.0I_s\\ &=(3.0)(1.5\text{ A})\\ &=4.5\text{ A} \end{aligned} \]

The source supplies 4.5 A.

The ideal transformer transfers power to both the load resistor and the series resistance, so its input current must account for both.

Part d: Verify conservation of energy.

Power dissipated by the internal series resistance:

\[ \begin{aligned} P_{\text{heat}} &=I_s^2r\\ &=(1.5\text{ A})^2(2.0\,\Omega)\\ &=4.5\text{ W} \end{aligned} \]

Power delivered to the external load:

\[ \begin{aligned} P_{\text{load}} &=I_s^2R_L\\ &=(1.5\text{ A})^2(10.0\,\Omega)\\ &=22.5\text{ W} \end{aligned} \]

Total power transferred to the secondary circuit:

\[ P_{\text{secondary}}=4.5+22.5=27.0\text{ W} \]

Input power:

\[ \begin{aligned} P_{\text{input}} &=V_pI_p\\ &=(6.0\text{ V})(4.5\text{ A})\\ &=27.0\text{ W} \end{aligned} \]

The power balance is correct.

All 27.0 W supplied by the source is accounted for: 22.5 W reaches the load, and 4.5 W is dissipated as heat.

Part e: Explain the misleading voltage ratio.

Using the measured load voltage gives

\[ \frac{V_s}{V_p}=\frac{15}{6.0}=2.5 \]

But the transformer has a turns ratio of \(3:1\), not \(2.5:1\).

The measured 15 V is only the voltage across the external load. It excludes the 3 V dropped across the internal series resistance.

The ideal transformer itself produces 18 V, so its true voltage transformation is

\[ \frac{18}{6.0}=3.0 \]

A student who uses the loaded terminal-voltage ratio to calculate the ideal transformer’s current ratio would also get the wrong input current.

The correct current transformation uses the actual turns ratio of the ideal transformer stage. The resistive heating calculation is then handled separately.

Question 5

A researcher is testing a small transformer with an unknown turns ratio.

The transformer is modelled as an ideal transformer followed by an unknown resistance \(r\) in series with its secondary. The primary voltage is maintained at 6.0 V RMS.

The researcher has two unusual voltmeters with relatively low input resistances:

  • Voltmeter A has an input resistance of \(1.0\,\text{k}\Omega\).
  • Voltmeter B has an input resistance of \(2.0\,\text{k}\Omega\).

The meters are accurate when measuring the voltage across their own terminals, but their finite input resistances can load the transformer.

When A alone is connected across the secondary, it reads 12.0 V RMS.

When A is disconnected and B alone is connected, B reads 14.4 V RMS.

Assume that \(r\) is constant, the transformer is ideal apart from this series resistance, and all resistances are purely resistive.

a. Determine \(r\) and the secondary-to-primary turns ratio.

b. Predict the voltage measured if A and B are connected across the secondary simultaneously, in parallel.

c. Calculate the current through each meter when both are connected. Explain why connecting the second meter makes the voltage reading fall, even though B alone previously measured a higher voltage.

d. Explain why neither of the two original measured voltage ratios gives the true turns ratio.

Solution 5

The series resistance is \(500\,\Omega\), and the secondary-to-primary turns ratio is \(3:1\). When both voltmeters are connected, they each read approximately 10.3 V, with different currents flowing through them.

The surprising feature is that the instruments aren’t passive observers. Each voltmeter changes the resistance connected to the secondary and therefore changes the very voltage it measures.

Part a: Determine the resistance and turns ratio.

Let \(E_s\) be the ideal secondary emf.

For a meter with resistance \(R\), the current through the secondary circuit is

\[ I=\frac{V}{R} \]

The induced emf must equal the meter voltage plus the drop across \(r\):

\[ E_s=V+Ir \]

Substituting \(I=V/R\),

\[ E_s=V\left(1+\frac{r}{R}\right) \]

For voltmeter A,

\[ E_s=12.0\left(1+\frac{r}{1000}\right) \]

For voltmeter B,

\[ E_s=14.4\left(1+\frac{r}{2000}\right) \]

Both equations describe the same ideal secondary emf.

Therefore,

\[ 12.0\left(1+\frac{r}{1000}\right) = 14.4\left(1+\frac{r}{2000}\right) \]

Expanding,

\[ 12.0+0.012r=14.4+0.0072r \]

Rearranging,

\[ \begin{aligned} 0.0048r&=2.4\\ r&=500\,\Omega \end{aligned} \]

Now calculate the ideal secondary emf using voltmeter A:

\[ \begin{aligned} E_s&=12.0\left(1+\frac{500}{1000}\right)\\ &=18.0\text{ V} \end{aligned} \]

The primary voltage is 6.0 V, so

\[ \begin{aligned} \frac{N_s}{N_p} &=\frac{E_s}{V_p}\\ &=\frac{18.0\text{ V}}{6.0\text{ V}}\\ &=3.0 \end{aligned} \]

The true turns ratio in the specified model is \(3:1\).

Part b: Predict the voltage with both meters connected.

When both meters are connected in parallel, their combined resistance is

\[ \frac{1}{R_{\parallel}} = \frac{1}{1000} + \frac{1}{2000} \]

Thus,

\[ R_{\parallel} = \frac{1000(2000)}{1000+2000} \]

\[ R_{\parallel}\approx666.7\,\Omega \]

This parallel combination is in series with the transformer’s \(500\,\Omega\) resistance.

Using the voltage-divider relationship,

\[ V=\frac{E_sR_{\parallel}}{r+R_{\parallel}} \]

Substitute the values:

\[ \begin{aligned} V&=\frac{18.0(666.7)}{500+666.7}\\ &\approx10.29\text{ V} \end{aligned} \]

Both meters read approximately 10.3 V.

Because they are connected in parallel, they measure the same potential difference.

Part c: Calculate the meter currents and explain the result.

Current through A:

\[ \begin{aligned} I_A&=\frac{10.29\text{ V}}{1000\,\Omega}\\ &=0.01029\text{ A} \end{aligned} \]

So,

\[ I_A\approx10.3\text{ mA} \]

Current through B:

\[ \begin{aligned} I_B&=\frac{10.29\text{ V}}{2000\,\Omega}\\ &=0.00514\text{ A} \end{aligned} \]

Therefore,

\[ I_B\approx5.14\text{ mA} \]

The total secondary current is approximately

\[ I_{\text{total}}=10.29+5.14=15.43\text{ mA} \]

The voltage drop across the series resistance is

\[ \begin{aligned} V_r&=I_{\text{total}}r\\ &=(0.01543\text{ A})(500\,\Omega)\\ &\approx7.71\text{ V} \end{aligned} \]

This leaves

\[ 18.0-7.71\approx10.29\text{ V} \]

across the meters, confirming the result.

Why is 10.29 V lower than either meter measured alone?

Adding B in parallel with A reduces the combined load resistance.

A smaller load resistance allows a larger total current to flow. That current produces a larger voltage drop across the transformer’s series resistance.

More of the 18.0 V induced emf is therefore lost across \(r\), leaving less voltage at the measurement terminals.

The tempting prediction is that adding a second voltmeter should improve the measurement or perhaps produce a reading between 12.0 V and 14.4 V.

But that treats the meters as if they draw no current.

Here, their resistance is part of the circuit. Connecting both changes the operating conditions.

Part d: Explain why the original voltage ratios are misleading.

Using voltmeter A alone would suggest

\[ \frac{12.0}{6.0}=2.0 \]

Using voltmeter B alone would suggest

\[ \frac{14.4}{6.0}=2.4 \]

Neither equals the actual turns ratio of 3.0.

Both readings are affected by voltage drops inside the transformer model.

If the secondary were genuinely unloaded, the series current would approach zero.

Consequently, the drop \(Ir\) would also approach zero, and the terminal voltage would approach the induced emf of 18.0 V.

The no-load voltage ratio would then be

\[ \frac{18.0}{6.0}=3.0 \]

This is why a high-input-resistance voltmeter is so useful for a transformer ratio test. It draws very little current, helping the measured terminal voltage approach the induced secondary emf.

The deeper lesson is that measurements aren’t always independent of the instruments used to obtain them.

A voltage reading can be perfectly accurate for the circuit that exists while the meter is connected and still give the wrong answer to the question you intended to investigate.

07The next measurement to make

Once you’ve estimated the turns ratio from no-load voltages, the next useful investigation is to keep the primary voltage as constant as possible and measure how the secondary terminal voltage changes as the load current increases.

That tests voltage regulation: how well the transformer maintains its output voltage under different loads.

The turns ratio tells you how voltage is transformed by the windings. A loading investigation tells you how closely the actual output follows that ideal transformation.

Keeping those two questions separate is what turns a pair of voltmeter readings into useful evidence about a transformer.