Demagnetising Fields: How Shape Changes Internal Magnetism
Explore why an object's shape affects its internal magnetic field, how demagnetising factors work, and why elongated magnets have preferred magnetisation directions. Includes worked examples and challenging practice questions.
Take the same magnetic material and shape it into two different objects: a long, thin rod and a flat disc. Magnetise both objects to the same magnetisation. Will the magnetic field inside them be identical?
It seems reasonable to predict that it will. After all, the material and its magnetisation are the same. But the prediction is wrong. The rod and disc produce different internal magnetic fields because their shapes change how the field generated by their own magnetisation is distributed.
This effect is called a demagnetising field. It is an extension beyond the required Year 11 Physics (2025) syllabus, not an HSC assessment requirement. However, it builds naturally on the field and energy concepts you’ve already studied.
01Start with electric fields and potential energy
Before looking at magnetism, recall something from electrostatics: a charged particle’s electric potential energy depends on its position in an electric field.
Imagine placing a positive charge between two oppositely charged parallel plates. The electric field points from the positive plate towards the negative plate.
The charge experiences an electric force:
\[ F=qE \]
Here:
- \(F\) is the electric force, measured in newtons (N).
- \(q\) is the charge, measured in coulombs (C).
- \(E\) is the electric field strength, measured in N/C.
Now predict what happens if the positive charge moves in the direction of the electric field.
The field does positive work on the charge. If the charge moves freely, it gains kinetic energy, so its electric potential energy decreases.
The reverse happens if you move the positive charge against the field. You must do work against the electric force, increasing the system’s potential energy.
For a uniform electric field, the change in electric potential energy is:
\[ \Delta U=-qEd_{\parallel} \]
Where:
- \(\Delta U\) is the change in electric potential energy (J).
- \(q\) is the particle’s charge (C).
- \(E\) is the electric field strength (N/C).
- \(d_{\parallel}\) is the signed displacement parallel to the electric field (m).
The sign of the charge matters.
- A positive charge moving along the field loses potential energy.
- A negative charge moving along the field gains potential energy.
- A displacement perpendicular to a uniform field produces no change in potential energy.
For example, consider a positive charge of \(2.0\times10^{-6}\ \mathrm C\) moving \(0.40\ \mathrm m\) along an electric field of \(300\ \mathrm{N/C}\).
Its change in potential energy is:
\[ \begin{aligned} \Delta U&=-qEd_{\parallel}\\ &=-(2.0\times10^{-6})(300)(0.40)\\ &=-2.4\times10^{-4}\ \mathrm J \end{aligned} \]
The negative result tells us that the electric potential energy decreases by \(2.4\times10^{-4}\ \mathrm J\).
Electric potential is the potential energy per unit charge:
\[ V=\frac{U}{q} \]
Therefore:
\[ \Delta U=q\Delta V \]
This is an important distinction: electric potential is measured in volts, whereas electric potential energy is measured in joules.
The key idea is that a field affects the energy of a system, and the configuration of that system matters.
For a magnetic material, we can take this idea further. Its magnetisation produces its own magnetic field, and the shape of the material affects the field and the associated magnetic energy.
If you need to revisit the difference between contact and field interactions, see Contact Forces and Field Forces in HSC Physics.
02Where does a demagnetising field come from?
To understand the effect of shape, we first need to understand magnetisation.
Magnetisation: a material’s overall magnetic alignment
Inside a magnetic material, many atoms contribute magnetic moments. These moments arise from the magnetic properties of electrons.
In an unmagnetised material, the individual magnetic moments may point in different directions. Their contributions largely cancel, producing little or no overall magnetisation.
When the moments become preferentially aligned, the material develops a net magnetic moment.
We describe this using magnetisation, represented by \(M\).
Magnetisation is the net magnetic dipole moment per unit volume:
\[ M=\frac{\text{net magnetic dipole moment}}{\text{volume}} \]
Its SI unit is amperes per metre (A/m).
A useful mental picture is a large collection of tiny bar magnets pointing in approximately the same direction.
Now consider what happens at the surface of the material.
Inside a uniformly magnetised object, neighbouring microscopic magnetic dipoles largely cancel one another’s contributions at their shared boundaries.
At the outer surface, however, there are no neighbouring dipoles beyond the material to complete that cancellation.
This leaves an effective pattern of magnetic poles at the surface.
These are sometimes called magnetic surface charges, but don’t take that name too literally. They are a mathematical model of magnetisation, not actual isolated magnetic monopoles. Magnetic field lines still form continuous loops.
For a uniformly magnetised material, the effective surface pole density is proportional to:
\[ \sigma_m=\mathbf M\cdot\hat{\mathbf n} \]
Here:
- \(\sigma_m\) is the effective magnetic surface pole density (A/m).
- \(\mathbf M\) is the magnetisation vector.
- \(\hat{\mathbf n}\) is the outward unit vector perpendicular to the surface.
This equation gives us an important insight.
A surface contributes most strongly to the effective magnetic poles when its outward normal points along or opposite to the magnetisation.
A surface parallel to the magnetisation has no effective pole density in this simple model.
Why the shape matters
Return to the rod and disc.
Case 1: A long rod magnetised along its length
The effective magnetic poles appear mainly at the two small end faces.
The field they produce inside the rod opposes the magnetisation. However, the geometry produces a relatively weak opposing field because the rod is long and slender.
Case 2: A thin disc magnetised perpendicular to its broad faces
The effective poles appear across the two large faces.
These faces produce a much stronger opposing internal field. The demagnetising field is therefore substantially larger.
The important point is that the material does not need to change for its internal magnetic field to change.
The arrangement of its surfaces changes the field produced by its own magnetisation.
This is the physical origin of the demagnetising field.
03Defining the demagnetising field
We can now describe the effect mathematically.
The demagnetising field, represented by \(H_d\), is the magnetic field strength produced by a material’s own magnetisation that opposes that magnetisation in the simple uniformly magnetised, principal-axis model.
To understand its effect, distinguish three quantities.
| Quantity | Symbol | Meaning | SI unit |
|---|---|---|---|
| Magnetisation | \(M\) | Magnetic dipole moment per unit volume | A/m |
| Applied field | \(H_a\) | Magnetic field strength applied externally | A/m |
| Demagnetising field | \(H_d\) | Field produced by the sample’s magnetisation | A/m |
The total internal magnetic field strength is the sum of the applied and demagnetising fields:
\[ H_{\mathrm{int}}=H_a+H_d \]
For a uniformly magnetised ellipsoid, when magnetisation is along one of its principal axes, the demagnetising field is:
\[ \boxed{H_d=-NM} \]
Where:
- \(H_d\) is the demagnetising field (A/m).
- \(N\) is the dimensionless demagnetising factor.
- \(M\) is the magnetisation (A/m).
The negative sign indicates that the demagnetising field opposes the magnetisation along the chosen principal axis.
The demagnetising factor \(N\) describes how strongly the object’s geometry produces this opposing field.
What determines the demagnetising factor?
The factor depends on the shape of the object and the direction in which it is magnetised.
It is not a property of the magnetic material itself.
For an ellipsoid, the factors along its three perpendicular principal axes satisfy:
\[ N_x+N_y+N_z=1 \]
In SI units, each factor lies between zero and one.
Some useful cases are:
| Shape and magnetisation direction | Demagnetising factor |
|---|---|
| Sphere, any direction | \(1/3\) |
| Very long rod, along its length | Approaches \(0\) |
| Very long rod, across its length | Approaches \(0.5\) |
| Very thin disc, perpendicular to its face | Approaches \(1\) |
| Very thin disc, within its face | Approaches \(0\) |
These limiting values give us a useful way to predict the strength of the demagnetising field.
- Small \(N\): weak demagnetising field.
- Large \(N\): strong demagnetising field.
For a more specific example, a prolate ellipsoid with a long-to-short axis ratio of 4:1 has approximately:
\[ N_{\mathrm{long}}=0.0754 \]
\[ N_{\mathrm{transverse}}=0.4623 \]
The same object therefore has very different demagnetising factors depending on its magnetisation direction.
One important limitation: the simple equation \(H_d=-NM\) with one constant \(N\) is exact for a uniformly magnetised ellipsoid along a principal axis.
For objects such as rectangular blocks and ordinary cylinders, the internal demagnetising field is generally non-uniform. A single demagnetising factor may still be used as an effective or average approximation, but it does not describe the field at every point.
This distinction matters when making accurate predictions about real magnetic components.
04The difference between magnetic field strength and magnetic flux density
There is another detail worth getting right before calculating anything.
In Year 11 Physics, you encounter magnetic fields, but more advanced treatments distinguish magnetic field strength \(H\) from magnetic flux density \(B\).
In SI units, inside a magnetic material:
\[ \boxed{B=\mu_0(H+M)} \]
Where:
- \(B\) is magnetic flux density (T).
- \(H\) is the internal magnetic field strength (A/m).
- \(M\) is magnetisation (A/m).
- \(\mu_0\) is the permeability of free space, approximately \(4\pi\times10^{-7}\ \mathrm{T\,m/A}\).
This equation is important because the demagnetising field and the total magnetic flux density are not the same thing.
Consider an ellipsoid with no externally applied field.
Then:
\[ H_a=0 \]
and:
\[ H_{\mathrm{int}}=H_d=-NM \]
Substituting into the expression for \(B\):
\[ \begin{aligned} B&=\mu_0(H_{\mathrm{int}}+M)\\ &=\mu_0(-NM+M) \end{aligned} \]
Therefore:
\[ \boxed{B=\mu_0(1-N)M} \]
This result applies when magnetisation is uniform and aligned with a principal axis.
Notice something interesting: even though the demagnetising field opposes the magnetisation, the magnetic flux density inside the material can still point in the direction of magnetisation.
That is because \(B\) depends on both \(H\) and \(M\).
05Why shape affects magnetic energy
So far, we’ve looked at how shape changes the internal magnetic field.
But there is another consequence: shape also changes the energy of a magnetised object.
This is called magnetostatic energy, or demagnetising energy.
For a uniformly magnetised ellipsoid, its demagnetising energy per unit volume is:
\[ u_d=\frac{1}{2}\mu_0 \left(N_xM_x^2+N_yM_y^2+N_zM_z^2\right) \]
Here:
- \(u_d\) is demagnetising energy per unit volume (J/m³).
- \(N_x,N_y,N_z\) are the demagnetising factors along the three principal axes.
- \(M_x,M_y,M_z\) are the corresponding magnetisation components.
- \(\mu_0\) is the permeability of free space.
If magnetisation points entirely along one principal axis, the expression simplifies to:
\[ \boxed{u_d=\frac{1}{2}\mu_0NM^2} \]
This equation reveals why elongated magnets behave differently from flat magnets.
For the same magnetisation magnitude, a smaller demagnetising factor produces a smaller magnetostatic energy.
A long magnetic rod therefore has a lower demagnetising energy when magnetised along its length than when magnetised across its width.
The object has a preferred magnetisation direction because of its shape.
This preference is called shape anisotropy.
There is an important qualification.
Real ferromagnetic materials also have a property called magnetocrystalline anisotropy. This means their internal crystal structure can favour particular magnetisation directions.
Shape anisotropy and magnetocrystalline anisotropy can compete.
Furthermore, a sufficiently large magnetic object may form magnetic domains: regions with different magnetisation directions. Domain formation can reduce the overall magnetic energy, so the object may not remain uniformly magnetised.
For now, our equations describe the idealised, uniformly magnetised ellipsoid. They give us a useful foundation without requiring a full treatment of magnetic domains.
06Worked examples
Worked example: A uniformly magnetised sphere
A spherical magnetic sample has a uniform magnetisation of \(5.0\times10^5\ \mathrm{A/m}\). No external magnetic field is applied.
Calculate its demagnetising field and internal magnetic flux density.
Step 1
For a sphere, the demagnetising factor is identical in every direction:
\[ N=\frac{1}{3} \]
Step 2
Use:
\[ H_d=-NM \]
Substitute:
\[ \begin{aligned} H_d&=-\frac{1}{3}(5.0\times10^5)\\ &=-1.67\times10^5\ \mathrm{A/m} \end{aligned} \]
The demagnetising field has a magnitude of \(1.67\times10^5\ \mathrm{A/m}\), opposite to the magnetisation.
Step 3
Since no external field is applied:
\[ H_{\mathrm{int}}=H_a+H_d \]
\[ H_{\mathrm{int}}=0-1.67\times10^5 \]
\[ H_{\mathrm{int}}=-1.67\times10^5\ \mathrm{A/m} \]
Step 4
Use:
\[ B=\mu_0(H_{\mathrm{int}}+M) \]
Substitute:
\[ \begin{aligned} B&=4\pi\times10^{-7} (5.0\times10^5-1.67\times10^5)\\ &=4\pi\times10^{-7}(3.33\times10^5)\\ &\approx0.419\ \mathrm T \end{aligned} \]
Final answer:
\[ \boxed{H_d=-1.67\times10^5\ \mathrm{A/m}} \]
\[ \boxed{B=0.419\ \mathrm T} \]
The demagnetising field opposes the magnetisation, but the resultant magnetic flux density still points along the magnetisation.
This is why it is important not to confuse \(H_d\) with \(B\).
Worked example: Changing the magnetisation direction of an ellipsoid
A prolate ellipsoid has a long-to-short axis ratio of 4:1.
Its demagnetising factors are:
\[ N_{\mathrm{long}}=0.0754 \]
\[ N_{\mathrm{transverse}}=0.4623 \]
The object has a uniform magnetisation of \(6.0\times10^5\ \mathrm{A/m}\). An external magnetic field of \(1.0\times10^5\ \mathrm{A/m}\) is applied in the same direction as the magnetisation.
Calculate the internal magnetic field strength and magnetic flux density when the magnetisation is along the long axis.
Step 1
The magnetisation is along the long axis, so:
\[ N=0.0754 \]
Using the transverse factor would produce an incorrect result.
Step 2
\[ H_d=-NM \]
\[ \begin{aligned} H_d&=-(0.0754)(6.0\times10^5)\\ &=-4.524\times10^4\ \mathrm{A/m} \end{aligned} \]
Step 3
\[ H_{\mathrm{int}}=H_a+H_d \]
\[ \begin{aligned} H_{\mathrm{int}} &=1.0\times10^5-4.524\times10^4\\ &=5.476\times10^4\ \mathrm{A/m} \end{aligned} \]
Step 4
\[ B=\mu_0(H_{\mathrm{int}}+M) \]
\[ \begin{aligned} B&=4\pi\times10^{-7} (5.476\times10^4+6.0\times10^5)\\ &=4\pi\times10^{-7}(6.5476\times10^5)\\ &\approx0.823\ \mathrm T \end{aligned} \]
Final answer:
\[ \boxed{H_{\mathrm{int}}=5.48\times10^4\ \mathrm{A/m}} \]
\[ \boxed{B=0.823\ \mathrm T} \]
The internal magnetic field strength is smaller than the applied field because the demagnetising field opposes it.
However, the magnetisation still contributes to the magnetic flux density, giving a resultant value of approximately \(0.823\ \mathrm T\).
07An application: Why magnetic measurements depend on sample shape
Demagnetising fields are not just a theoretical curiosity. They affect how scientists measure the magnetic properties of materials.
Consider a material that responds linearly to an applied magnetic field.
Its magnetisation can be written as:
\[ M=\chi H_{\mathrm{int}} \]
Here, \(\chi\) is the magnetic susceptibility, a dimensionless quantity in SI units.
It describes how strongly the material becomes magnetised in response to its internal magnetic field.
Since:
\[ H_{\mathrm{int}}=H_a-NM \]
we can substitute:
\[ M=\chi(H_a-NM) \]
Rearranging:
\[ M+\chi NM=\chi H_a \]
\[ M(1+\chi N)=\chi H_a \]
The susceptibility calculated using the externally applied field is therefore:
\[ \boxed{\chi_{\mathrm{ext}}= \frac{\chi}{1+\chi N}} \]
This is called the apparent or external susceptibility.
It tells us something important: the same material can appear to have different magnetic susceptibilities when measured in different shapes or orientations.
A sample with a larger demagnetising factor has a smaller apparent susceptibility in this model.
This equation assumes a linear, reversible magnetic response and uniform magnetisation along a principal axis of an ellipsoid. It should not be applied indiscriminately to saturated or hysteretic magnets.
08Common misconceptions
Before practising, make sure you can distinguish these three ideas.
| Common misconception | Correct understanding |
|---|---|
| The demagnetising field is the same as the magnetic flux density. | \(H_d\) is one contribution to the internal magnetic field strength. \(B\) also depends on magnetisation. |
| Demagnetising fields depend only on the material. | They depend strongly on the object’s shape and magnetisation direction. |
| The demagnetising field always points exactly opposite to magnetisation. | This is true for uniform magnetisation along a principal axis of an ellipsoid, but not generally for oblique magnetisation or arbitrary shapes. |
| Every object has one fixed demagnetising factor. | An ellipsoid has different factors along its principal axes. For other shapes, a single factor is generally an approximation. |
| A demagnetising field means the magnet has been demagnetised. | The field exists because of the magnetisation itself. It is not the same as deliberately reducing a magnet’s permanent magnetisation. |
The most useful decision rule is simple: identify the shape, identify the magnetisation direction, and only then select the demagnetising factor.
09Questions and solutions
Question 1
A spherical magnetic sample has a uniform magnetisation of \(4.2\times10^5\ \mathrm{A/m}\). There is no externally applied magnetic field.
Calculate:
a) The demagnetising factor.
b) The demagnetising field.
c) The internal magnetic flux density.
Solution 1
The demagnetising field is \(-1.4\times10^5\ \mathrm{A/m}\), and the internal magnetic flux density is \(0.352\ \mathrm T\) along the magnetisation.
Part a: Demagnetising factor
For a sphere:
\[ \boxed{N=\frac13} \]
The value is independent of the magnetisation direction because a sphere has identical geometry in every direction.
Part b: Demagnetising field
Use:
\[ H_d=-NM \]
Substitute:
\[ \begin{aligned} H_d&=-\frac13(4.2\times10^5)\\ &=-1.4\times10^5\ \mathrm{A/m} \end{aligned} \]
Part c: Internal magnetic flux density
There is no applied field, so:
\[ H_{\mathrm{int}}=H_d \]
Using:
\[ B=\mu_0(H_{\mathrm{int}}+M) \]
gives:
\[ \begin{aligned} B&=4\pi\times10^{-7} (4.2\times10^5-1.4\times10^5)\\ &=4\pi\times10^{-7}(2.8\times10^5)\\ &\approx0.352\ \mathrm T \end{aligned} \]
The magnetic flux density remains in the direction of magnetisation because the contribution from \(M\) is larger than the opposing contribution from \(H_d\).
Question 2
A prolate ellipsoid has the following demagnetising factors:
\[ N_{\mathrm{long}}=0.0754 \]
\[ N_{\mathrm{transverse}}=0.4623 \]
Its uniform magnetisation has a magnitude of \(7.0\times10^5\ \mathrm{A/m}\).
An applied magnetic field of \(1.2\times10^5\ \mathrm{A/m}\) is directed along the magnetisation.
Calculate the internal magnetic field strength and magnetic flux density in each of the following cases:
a) Magnetisation along the long axis.
b) Magnetisation along a transverse axis.
c) Explain why the internal magnetic field strength can point opposite to the magnetisation while the magnetic flux density still points along it.
Solution 2
The internal flux density is approximately \(0.964\ \mathrm T\) along the long axis and \(0.624\ \mathrm T\) along the transverse axis.
Part a: Magnetisation along the long axis
Use the long-axis demagnetising factor:
\[ N=0.0754 \]
Calculate the demagnetising field:
\[ \begin{aligned} H_d&=-NM\\ &=-(0.0754)(7.0\times10^5)\\ &=-5.278\times10^4\ \mathrm{A/m} \end{aligned} \]
Calculate the internal field strength:
\[ \begin{aligned} H_{\mathrm{int}} &=H_a+H_d\\ &=1.2\times10^5-5.278\times10^4\\ &=6.722\times10^4\ \mathrm{A/m} \end{aligned} \]
Calculate the magnetic flux density:
\[ \begin{aligned} B&=\mu_0(H_{\mathrm{int}}+M)\\ &=4\pi\times10^{-7} (6.722\times10^4+7.0\times10^5)\\ &\approx0.964\ \mathrm T \end{aligned} \]
Part b: Magnetisation along a transverse axis
Now use:
\[ N=0.4623 \]
Calculate the demagnetising field:
\[ \begin{aligned} H_d&=-(0.4623)(7.0\times10^5)\\ &=-3.2361\times10^5\ \mathrm{A/m} \end{aligned} \]
Calculate the internal field strength:
\[ \begin{aligned} H_{\mathrm{int}} &=1.2\times10^5-3.2361\times10^5\\ &=-2.0361\times10^5\ \mathrm{A/m} \end{aligned} \]
Calculate the magnetic flux density:
\[ \begin{aligned} B&=4\pi\times10^{-7} (-2.0361\times10^5+7.0\times10^5)\\ &=4\pi\times10^{-7}(4.9639\times10^5)\\ &\approx0.624\ \mathrm T \end{aligned} \]
Part c: Explain the directions
The internal magnetic field strength is negative in the transverse case because the demagnetising field is stronger than the applied field.
However:
\[ B=\mu_0(H_{\mathrm{int}}+M) \]
The magnetisation is still larger in magnitude than the negative internal field strength. Consequently, their sum is positive.
The flux density therefore still points along the magnetisation.
The key result is that changing the orientation of the same ellipsoid changes its demagnetising field, even though its material and magnetisation magnitude remain unchanged.
Question 3
A uniformly magnetised triaxial ellipsoid has the following demagnetising factors:
\[ N_x=0.20,\qquad N_y=0.30,\qquad N_z=0.50 \]
Its magnetisation has components:
\[ M_x=3.0\times10^5\ \mathrm{A/m} \]
\[ M_y=0 \]
\[ M_z=4.0\times10^5\ \mathrm{A/m} \]
There is no externally applied magnetic field.
a) Calculate the three components of the demagnetising field.
b) Determine whether the demagnetising field is exactly antiparallel to the magnetisation.
c) Explain why your result does not contradict the idea that a demagnetising field opposes magnetisation.
Solution 3
The demagnetising field is:
\[ \boxed{\mathbf H_d= (-6.0\times10^4,\ 0,\ -2.0\times10^5)\ \mathrm{A/m}} \]
It is not exactly antiparallel to the magnetisation because the demagnetising factors differ between the principal axes.
Part a: Calculate the field components
For a uniformly magnetised ellipsoid, each principal component is calculated separately:
\[ H_{d,x}=-N_xM_x \]
\[ H_{d,y}=-N_yM_y \]
\[ H_{d,z}=-N_zM_z \]
Substitute the supplied values.
For the x-component:
\[ H_{d,x}=-(0.20)(3.0\times10^5) \]
\[ H_{d,x}=-6.0\times10^4\ \mathrm{A/m} \]
For the y-component:
\[ H_{d,y}=-(0.30)(0)=0 \]
For the z-component:
\[ H_{d,z}=-(0.50)(4.0\times10^5) \]
\[ H_{d,z}=-2.0\times10^5\ \mathrm{A/m} \]
Therefore:
\[ \boxed{ \mathbf H_d= (-6.0\times10^4,\ 0,\ -2.0\times10^5) \ \mathrm{A/m} } \]
Part b: Compare the directions
The magnetisation vector has a magnitude:
\[ \begin{aligned} M&=\sqrt{M_x^2+M_z^2}\\ &=\sqrt{(3.0\times10^5)^2+(4.0\times10^5)^2}\\ &=5.0\times10^5\ \mathrm{A/m} \end{aligned} \]
Its angle from the positive z-axis is:
\[ \theta_M=\tan^{-1}\left(\frac{3}{4}\right) \]
\[ \theta_M=36.9^\circ \]
The demagnetising field has an angle of:
\[ \theta_H=\tan^{-1}\left(\frac{6.0\times10^4}{2.0\times10^5}\right) \]
\[ \theta_H=16.7^\circ \]
measured from the negative z-axis towards the negative x-axis.
If the two vectors were exactly antiparallel, these angles would be equal.
They are not.
Part c: Explain the result
The demagnetising field opposes each component of magnetisation, but the strength of that opposition depends on the corresponding demagnetising factor.
Here, the z-axis has a larger demagnetising factor than the x-axis.
As a result, the z-component of the demagnetising field is relatively stronger, changing the overall direction of the field.
This is an important refinement: for an ellipsoid with magnetisation along an arbitrary direction, the demagnetising field does not necessarily point exactly opposite to the magnetisation.
It can also produce a torque that tends to rotate the magnetisation towards a lower-energy direction.
Question 4
A magnetic material has an intrinsic magnetic susceptibility of:
\[ \chi=5.0 \]
At low applied fields, the material responds linearly according to:
\[ M=\chi H_{\mathrm{int}} \]
A uniformly magnetised ellipsoid of revolution is tested along two perpendicular principal axes.
The measured external susceptibilities are:
| Applied field direction | Measured external susceptibility |
|---|---|
| z-axis | 1.25 |
| x-axis | 2.50 |
Assume the x- and y-axis demagnetising factors are equal.
a) Derive the relationship between intrinsic susceptibility, external susceptibility, and demagnetising factor.
b) Calculate \(N_z\) and \(N_x\).
c) Identify whether the ellipsoid is prolate or oblate, and explain what this tells you about its geometry.
Solution 4
The demagnetising factors are:
\[ \boxed{N_z=0.60} \]
\[ \boxed{N_x=N_y=0.20} \]
The ellipsoid is oblate, with its z-axis as the shorter symmetry axis.
Part a: Derive the susceptibility relationship
Start with the definition of intrinsic susceptibility:
\[ M=\chi H_{\mathrm{int}} \]
The internal field is:
\[ H_{\mathrm{int}}=H_a-NM \]
Substitute:
\[ M=\chi(H_a-NM) \]
Expand:
\[ M=\chi H_a-\chi NM \]
Collect the terms involving magnetisation:
\[ M+\chi NM=\chi H_a \]
Factorise:
\[ M(1+\chi N)=\chi H_a \]
Divide by \(H_a(1+\chi N)\):
\[ \frac{M}{H_a}=\frac{\chi}{1+\chi N} \]
Since the external susceptibility is:
\[ \chi_{\mathrm{ext}}=\frac{M}{H_a} \]
we obtain:
\[ \boxed{\chi_{\mathrm{ext}}= \frac{\chi}{1+\chi N}} \]
Part b: Calculate the demagnetising factors
Rearrange the expression:
\[ \chi_{\mathrm{ext}}(1+\chi N)=\chi \]
\[ 1+\chi N=\frac{\chi}{\chi_{\mathrm{ext}}} \]
Therefore:
\[ \boxed{N=\frac{1}{\chi} \left(\frac{\chi}{\chi_{\mathrm{ext}}}-1\right)} \]
For the z-axis:
\[ \begin{aligned} N_z&=\frac{1}{5.0} \left(\frac{5.0}{1.25}-1\right)\\ &=\frac{4-1}{5}\\ &=0.60 \end{aligned} \]
For the x-axis:
\[ \begin{aligned} N_x&=\frac{1}{5.0} \left(\frac{5.0}{2.50}-1\right)\\ &=\frac{2-1}{5}\\ &=0.20 \end{aligned} \]
Since the ellipsoid is a body of revolution around the z-axis:
\[ N_x=N_y \]
We can check the ellipsoid sum rule:
\[ N_x+N_y+N_z=1 \]
\[ 0.20+0.20+0.60=1.00 \]
The values are consistent.
Part c: Identify the shape
For an ellipsoid of revolution:
- A prolate ellipsoid has a long symmetry axis and a smaller demagnetising factor along that axis.
- An oblate ellipsoid has a short symmetry axis and a larger demagnetising factor along that axis.
Here:
\[ N_z=0.60 \]
is greater than:
\[ N_x=N_y=0.20 \]
Therefore, the z-axis is the shorter symmetry axis.
The object is an oblate ellipsoid, flattened perpendicular to z.
The smaller external susceptibility along z also makes sense: the stronger demagnetising field reduces the internal field available to produce magnetisation.
The measurements reveal information about the specimen’s geometry, not a change in the intrinsic magnetic properties of the material.
Question 5
An ideal single-domain prolate ellipsoid has the following demagnetising factors:
\[ N_x=N_y=0.46 \]
\[ N_z=0.08 \]
Its long axis is the z-axis, and its saturation magnetisation is:
\[ M_s=8.0\times10^5\ \mathrm{A/m} \]
A short external magnetic field pulse has left the ellipsoid with the following magnetisation components:
\[ M_x=0.60M_s \]
\[ M_y=0 \]
\[ M_z=0.80M_s \]
The external field has now been switched off.
Assume that:
- The magnetisation magnitude remains constant.
- The magnetisation rotates coherently as a single domain.
- There is no magnetocrystalline anisotropy.
- The object does not form magnetic domains.
- Thermal effects are ignored.
A student argues:
“The demagnetising factors add to one, so the average factor is \(1/3\). Therefore, the demagnetising field must point exactly opposite to the magnetisation. It simply reduces the field strength, so the magnetisation direction will not change.”
Evaluate this argument.
Your response must:
a) Calculate the actual demagnetising field vector.
b) Determine whether it is antiparallel to the magnetisation.
c) Predict the direction in which the magnetisation will rotate after the external field is removed.
d) Calculate the decrease in magnetostatic energy per unit volume when the magnetisation reaches its final stable orientation.
Solution 5
The student’s argument is incorrect. The demagnetising field is not antiparallel to the initial magnetisation, and it produces a torque that rotates the magnetisation towards the long z-axis.
The magnetostatic energy decreases by approximately:
\[ \boxed{5.5\times10^4\ \mathrm{J/m^3}} \]
Part a: Calculate the demagnetising field vector
First calculate the magnetisation components.
\[ \begin{aligned} M_x&=0.60(8.0\times10^5)\\ &=4.8\times10^5\ \mathrm{A/m} \end{aligned} \]
\[ \begin{aligned} M_z&=0.80(8.0\times10^5)\\ &=6.4\times10^5\ \mathrm{A/m} \end{aligned} \]
The magnetisation magnitude is consistent with the supplied saturation value:
\[ M=\sqrt{(0.60M_s)^2+(0.80M_s)^2}=M_s \]
Now calculate the demagnetising field components separately.
Along x:
\[ \begin{aligned} H_{d,x}&=-N_xM_x\\ &=-(0.46)(4.8\times10^5)\\ &=-2.208\times10^5\ \mathrm{A/m} \end{aligned} \]
Along z:
\[ \begin{aligned} H_{d,z}&=-N_zM_z\\ &=-(0.08)(6.4\times10^5)\\ &=-5.12\times10^4\ \mathrm{A/m} \end{aligned} \]
There is no y-component.
Therefore:
\[ \boxed{ \mathbf H_d= (-2.208\times10^5,\ 0,\ -5.12\times10^4) \ \mathrm{A/m} } \]
Part b: Is the demagnetising field antiparallel to magnetisation?
No.
The magnetisation angle from the positive z-axis is:
\[ \theta_M=\tan^{-1}\left(\frac{0.60}{0.80}\right) \]
\[ \theta_M=36.9^\circ \]
The demagnetising field angle from the negative z-axis towards the negative x-axis is:
\[ \theta_H=\tan^{-1} \left(\frac{2.208\times10^5}{5.12\times10^4}\right) \]
\[ \theta_H\approx76.9^\circ \]
If the demagnetising field were exactly antiparallel to magnetisation, this angle would be \(36.9^\circ\).
Instead, it is approximately \(76.9^\circ\).
The reason is that the x-axis has a much larger demagnetising factor than the z-axis.
The two components of magnetisation are opposed by different amounts. The resulting field is therefore not simply a scaled version of the original magnetisation vector.
Part c: Predict the direction of rotation
With the external field switched off:
\[ H_{\mathrm{int}}=H_d \]
The internal magnetic field is not parallel to the magnetisation.
A magnetic moment experiences a torque in a magnetic field. For a magnetised material, the torque density is related to:
\[ \boldsymbol{\tau}/V = \mu_0\mathbf M\times\mathbf H_d \]
Because the demagnetising field is not antiparallel to the magnetisation, this torque is non-zero.
The torque drives the magnetisation towards a lower-energy orientation.
Since the long z-axis has the smallest demagnetising factor, the magnetisation rotates towards the positive z-axis.
The student’s mistake was treating the sum of the three demagnetising factors as though it gave one universal factor for every direction.
The sum rule:
\[ N_x+N_y+N_z=1 \]
does not mean that every direction has \(N=1/3\).
That value applies to a sphere, not to an arbitrary direction in an elongated ellipsoid.
Part d: Calculate the decrease in magnetostatic energy
For a uniformly magnetised ellipsoid:
\[ u_d=\frac12\mu_0 (N_xM_x^2+N_yM_y^2+N_zM_z^2) \]
Initially, the magnetisation has components along x and z.
Using:
\[ M_x=0.60M_s \]
and:
\[ M_z=0.80M_s \]
the initial energy density is:
\[ u_i=\frac12\mu_0M_s^2 \left[N_x(0.60)^2+N_z(0.80)^2\right] \]
Substitute:
\[ \begin{aligned} u_i&=\frac12\mu_0M_s^2 [(0.46)(0.36)+(0.08)(0.64)]\\ &=\frac12\mu_0M_s^2(0.2168) \end{aligned} \]
At the final stable orientation, magnetisation is entirely along the z-axis.
Therefore:
\[ u_f=\frac12\mu_0M_s^2N_z \]
\[ u_f=\frac12\mu_0M_s^2(0.08) \]
The decrease in energy density is:
\[ \Delta u=u_i-u_f \]
\[ \Delta u=\frac12\mu_0M_s^2(0.2168-0.08) \]
Substitute:
\[ \begin{aligned} \Delta u &=\frac12(4\pi\times10^{-7}) (8.0\times10^5)^2(0.1368)\\ &\approx5.50\times10^4\ \mathrm{J/m^3} \end{aligned} \]
Therefore:
\[ \boxed{\Delta u=5.5\times10^4\ \mathrm{J/m^3}} \]
The magnetisation reaches the long-axis orientation because this produces a lower magnetostatic energy.
The energy reduction is not simply the result of a weaker magnetic field. It is the result of the entire magnetisation distribution changing its orientation relative to the object’s geometry.
In a real material, magnetocrystalline anisotropy, domain formation, and other effects could alter the final state. The question’s assumptions deliberately isolate shape anisotropy.
10Where to take this idea next
Demagnetising fields show that the magnetic behaviour of a material cannot always be understood by looking at the material alone. Its geometry changes the internal field, the magnetic energy, and even the preferred direction of magnetisation.
The natural next step is magnetic domains and hysteresis.
These concepts explain what happens when a real ferromagnetic material responds to an applied field by rearranging regions of magnetisation rather than rotating as one uniformly magnetised object.
11Further reading
The models and relationships in this article are consistent with the following scientific and educational references:
- NSW Education Standards Authority – Physics 11-12 Syllabus (2025).
- OpenStax – University Physics, Electric Potential and Potential Difference.
- NIST-hosted reference – Demagnetizing Factors.
- J. A. Osborn (1945) – Demagnetizing Factors of the General Ellipsoid, Physical Review.
- NPTEL – Magnetic Anisotropy and Shape Anisotropy.