Coupling Coefficients: Magnetic Flux Linkage in Real Transformers

An extension of Year 12 Electromagnetism explaining how the coefficient of coupling describes shared magnetic flux, and why leakage inductance, eddy currents, and winding resistance affect a real transformer's output and efficiency.

Two transformers can have the same turns ratio and receive the same AC supply, yet deliver different amounts of power to their loads. One reason is that the magnetic flux produced by the primary winding does not necessarily pass through every turn of the secondary winding.

This raises an interesting question: how completely do two coils need to share a magnetic field for a transformer to work effectively?

The answer can be described using a quantity called the coefficient of coupling.

Where this topic fits: The NSW Physics 11-12 Syllabus (2025) introduces ideal transformers and requires students to explain differences between ideal and real transformer power output using incomplete flux linkage, eddy currents, and resistive heating. The mathematical treatment of coupling coefficients in this article goes beyond the required syllabus. It is an extension of Year 12 Electromagnetism, not an HSC assessment requirement.

The 2025 syllabus is scheduled for implementation from 2027, with its first HSC examination in 2028.

01Start with the transformer model you already know

A transformer contains two coils of wire, called the primary and secondary windings, arranged around a shared magnetic core.

An alternating current in the primary winding produces a changing magnetic field. This creates a changing magnetic flux through the core, which induces an electromotive force (emf) in the secondary winding.

For an ideal transformer, the voltage relationship is:

\[ \frac{V_p}{V_s}=\frac{N_p}{N_s} \]

Here:

  • \(V_p\) is the primary voltage, measured in volts.
  • \(V_s\) is the secondary voltage, measured in volts.
  • \(N_p\) is the number of primary turns.
  • \(N_s\) is the number of secondary turns.

The ideal transformer also assumes that power is conserved:

\[ P_{\mathrm{in}}=P_{\mathrm{out}} \]

For an ideal transformer operating with the same power factor on both sides, this gives:

\[ V_p I_p=V_s I_s \]

where \(I_p\) and \(I_s\) are the primary and secondary RMS currents.

These equations rely on an important assumption: all the magnetic flux produced by one winding links the other winding.

In a real transformer, this assumption is not perfectly satisfied.

02Perfect flux linkage versus incomplete flux linkage

Imagine two coils wrapped around the same iron core.

When current flows through the primary, it produces magnetic flux. Some of this flux travels through the shared core and passes through both windings.

This is called the mutual flux because it links both coils.

However, some magnetic flux may take a different path. It might loop around the primary winding without passing through the secondary.

This is called leakage flux.

A useful way to picture this is to imagine a shared route between two locations. The mutual flux follows a route that passes through both coils, while leakage flux takes a side route that only links one.

The analogy has a limit: magnetic flux is not a substance travelling through a pipe. It is a measure of the magnetic field passing through an area.

The important distinction is that only the flux linking the secondary contributes to the mutual induction produced by the primary current.

Why does incomplete flux linkage matter?

Recall Faraday’s law:

\[ \varepsilon=-N\frac{\Delta\Phi}{\Delta t} \]

Here:

  • \(\varepsilon\) is the induced emf in volts.
  • \(N\) is the number of turns.
  • \(\Delta\Phi\) is the change in magnetic flux in webers.
  • \(\Delta t\) is the time interval in seconds.

The negative sign represents Lenz’s law: the induced emf acts in a direction that opposes the change producing it.

For the secondary winding, the relevant flux is the changing flux that actually links its turns.

If some of the primary’s flux does not link the secondary, it cannot contribute to the secondary’s mutually induced emf.

This can affect the secondary voltage, particularly when the transformer is supplying a load.

But there is an important distinction.

Does leakage flux mean that the same percentage of input power is automatically wasted?

No.

Leakage flux is not automatically converted into heat. Magnetic fields can store energy and return it to the circuit during an AC cycle. Incomplete linkage mainly introduces an additional inductive effect that influences the voltage available to the load.

Some leakage flux can also induce unwanted currents in nearby conducting materials, producing additional heating. We will return to this when examining eddy currents.

03Introducing the coefficient of coupling

Engineers need a way to describe how strongly two coils are magnetically connected.

The coefficient of coupling, represented by \(k\), provides this measurement.

It is based on three inductance quantities:

  • \(L_p\): the self-inductance of the primary coil, measured in henries (H).
  • \(L_s\): the self-inductance of the secondary coil, measured in henries (H).
  • \(M\): the mutual inductance between the two coils, also measured in henries (H).

Self-inductance describes how a changing current in a coil produces an induced emf in that same coil.

Mutual inductance describes how a changing current in one coil produces an induced emf in the other coil.

The coefficient of coupling is defined as:

\[ \boxed{k=\frac{|M|}{\sqrt{L_pL_s}}} \]

Equivalently:

\[ \boxed{|M|=k\sqrt{L_pL_s}} \]

The absolute value is used because the sign of mutual inductance can depend on the winding orientation. Here, we are interested in the strength of the coupling rather than its polarity.

For the simple model of two passive, linearly responding coils:

\[ 0\leq k\leq 1 \]

The two limiting cases are particularly important.

Coupling coefficientPhysical meaning
\(k=1\)Perfect coupling. All relevant flux is shared between the coils.
\(0<k<1\)Imperfect coupling. Some flux does not link both coils.
\(k=0\)No mutual coupling between the coils.

A higher value of \(k\) indicates stronger magnetic coupling.

A lower value indicates a greater relative influence of leakage flux.

One important mathematical detail

You might be tempted to interpret \(k=0.90\) as meaning exactly 90% of the primary’s magnetic flux reaches the secondary.

That is not generally correct.

The coefficient is a normalised measure of mutual inductance compared with the maximum possible mutual inductance for the two measured self-inductances.

For a simplified common-core arrangement, it is useful to think of \(k\) as indicating how much of the magnetic behaviour is shared. However, it is not universally identical to a direct percentage of flux linkage.

It is also not transformer efficiency.

A transformer with \(k=0.99\) does not automatically have 99% efficiency. Its winding resistance and core losses still matter.

This distinction is essential when comparing real transformers.

Worked example: Calculate the coefficient of coupling

A transformer has a primary self-inductance of \(0.40\,\text{H}\), a secondary self-inductance of \(0.10\,\text{H}\), and a mutual inductance of \(0.18\,\text{H}\).

Calculate the coefficient of coupling.

Step 1

\[ L_p=0.40\,\text{H} \]

\[ L_s=0.10\,\text{H} \]

\[ M=0.18\,\text{H} \]

Step 2

\[ k=\frac{|M|}{\sqrt{L_pL_s}} \]

Step 3

\[ k=\frac{0.18}{\sqrt{0.40\times0.10}} \]

\[ k=\frac{0.18}{\sqrt{0.040}} \]

\[ k=\frac{0.18}{0.20} \]

\[ \boxed{k=0.90} \]

The coils have a coefficient of coupling of 0.90.

This indicates strong magnetic coupling, although it is not perfect. The mutual inductance is 90% of the maximum possible value for these particular self-inductances.

It does not mean that 10% of the input power is lost.

What determines the coefficient of coupling?

The physical arrangement of the windings influences how much magnetic flux they share.

Consider two transformers.

In the first, the windings are positioned close together around a shared magnetic core. Most of the flux produced by either winding follows a path that links the other winding.

In the second, the windings are separated. A greater proportion of the magnetic field may follow paths that link only one winding.

The first arrangement generally has a higher coefficient of coupling.

Transformer designers can improve coupling by:

  • Positioning the primary and secondary windings closer together.
  • Using winding arrangements that allow the coils to share more of the same magnetic field.
  • Using a suitable shared magnetic core to provide a low-reluctance path for the magnetic flux.

Interleaving winding sections can also improve coupling, although insulation, cooling, and mechanical requirements place limits on the arrangement.

04Applying coupling coefficients to induced emf

The coupling coefficient becomes particularly useful when examining mutual induction.

Recall that mutual inductance relates the rate of change of current in one coil to the emf induced in the other.

For an open-circuit secondary, the magnitude of the induced emf is:

\[ |\varepsilon_s|=M\left|\frac{\Delta I_p}{\Delta t}\right| \]

Here:

  • \(\varepsilon_s\) is the induced secondary emf in volts.
  • \(M\) is the mutual inductance in henries.
  • \(\Delta I_p\) is the change in primary current in amperes.
  • \(\Delta t\) is the time interval in seconds.

This relationship assumes that the magnetic system behaves approximately linearly over the interval.

Combining it with the coupling coefficient equation gives:

\[ |\varepsilon_s| = k\sqrt{L_pL_s} \left|\frac{\Delta I_p}{\Delta t}\right| \]

This equation connects three ideas:

  1. The self-inductances of the two coils.
  2. How strongly their magnetic fields are coupled.
  3. The emf induced in the secondary by a changing primary current.

Worked example: Find the induced secondary emf

A pair of coupled coils has:

  • Primary self-inductance: \(0.25\,\text{H}\).
  • Secondary self-inductance: \(0.16\,\text{H}\).
  • Coefficient of coupling: \(0.95\).

The secondary is open-circuit. At a particular instant, the primary current is changing at \(24\,\text{A s}^{-1}\).

Calculate the magnitude of the induced secondary emf.

Step 1

Rearrange the coupling coefficient equation:

\[ M=k\sqrt{L_pL_s} \]

Substitute:

\[ M=0.95\sqrt{0.25\times0.16} \]

\[ M=0.95\sqrt{0.040} \]

\[ M=0.95\times0.20 \]

\[ M=0.19\,\text{H} \]

Step 2

\[ |\varepsilon_s| = M\left|\frac{\Delta I_p}{\Delta t}\right| \]

Substitute:

\[ |\varepsilon_s|=0.19\times24 \]

\[ \boxed{|\varepsilon_s|=4.56\,\text{V}} \]

The open-circuit secondary emf is \(4.56\,\text{V}\).

The result demonstrates that stronger coupling increases mutual inductance when the self-inductances remain unchanged.

However, this is an open-circuit calculation. If a load is connected, secondary current flows and produces its own magnetic field. This affects the primary current through Lenz’s law, so the original rate of change of primary current cannot automatically be assumed to remain constant.

Also, this equation does not mean that you can simply multiply the ideal transformer turns-ratio equation by \(k\). Actual transformer terminal voltages depend on the complete circuit, including leakage inductance, winding resistance, and the connected load.

05Why real transformers deliver less power

We can now separate three effects that explain the difference between ideal and real transformers.

They are related, but they do not all reduce output power in the same way.

1. Incomplete flux linkage and leakage inductance

In an ideal transformer, all the relevant magnetic flux links both windings.

In a practical transformer, some flux links only one winding.

This creates an effect called leakage inductance.

Leakage inductance behaves like an additional inductance in series with the transformer windings. It influences the voltage available at the secondary terminals when current flows.

For an AC circuit, inductance produces inductive reactance:

\[ X_L=2\pi fL \]

where:

  • \(X_L\) is inductive reactance in ohms.
  • \(f\) is the AC frequency in hertz.
  • \(L\) is inductance in henries.

A greater leakage inductance produces a greater leakage reactance at the same frequency.

When the secondary supplies a load, this reactance contributes to an internal voltage drop. Consequently, the secondary terminal voltage can decrease as the load current increases.

This is related to voltage regulation, which describes how well a transformer maintains its output voltage when its load changes.

There is a subtle but important point here.

An ideal inductor does not continuously dissipate real power. It stores energy in its magnetic field and returns that energy to the circuit.

Therefore, leakage inductance does not automatically represent an equivalent amount of power converted into heat.

However, leakage flux can pass through nearby conducting components, such as a transformer enclosure or metal supports. This can induce eddy currents in those materials, producing additional heating.

So incomplete flux linkage affects the useful transfer of electrical energy, but its magnetic field is not itself a direct heat-loss mechanism.

2. Eddy currents

The magnetic core of a transformer is usually made from an electrically conducting magnetic material, such as iron or electrical steel.

Remember that the magnetic flux in the core continually changes direction because the transformer operates using AC.

Faraday’s law tells us that a changing magnetic field can induce an emf in a conductor.

This means that the changing magnetic flux also induces currents within the conducting core itself.

These circulating currents are called eddy currents.

Eddy currents oppose the change in magnetic flux that produces them, consistent with Lenz’s law.

However, they also flow through a material with electrical resistance.

This produces resistive heating.

Some of the electrical energy supplied to the transformer is therefore converted into thermal energy within the core rather than being delivered to the secondary load.

How do transformer designers reduce eddy currents?

They use a laminated core.

Instead of constructing the core as one solid block of iron, manufacturers build it from many thin sheets of magnetic material.

Each sheet is electrically insulated from its neighbours.

This interrupts the paths available to circulating currents and restricts their size.

The smaller current loops reduce eddy-current losses.

Notice that laminations and improved magnetic coupling solve different problems:

  • Laminations reduce eddy-current heating.
  • Improved winding arrangements reduce leakage flux and increase magnetic coupling.

A transformer needs both strategies.

3. Resistive heating in the windings

The primary and secondary windings are made from conducting wire, usually copper.

Copper has a low electrical resistance, but it does not have zero resistance.

Whenever current passes through a resistance, electrical energy is converted into heat.

The power dissipated through a resistance is:

\[ P=I^2R \]

Here:

  • \(P\) is power dissipated in watts.
  • \(I\) is the RMS current in amperes.
  • \(R\) is electrical resistance in ohms.

For a transformer, the total winding loss can be represented as:

\[ P_{\mathrm{cu}} = I_p^2R_p+I_s^2R_s \]

where:

  • \(P_{\mathrm{cu}}\) is the total copper loss.
  • \(I_p\) and \(I_s\) are the primary and secondary RMS currents.
  • \(R_p\) and \(R_s\) are the resistances of the primary and secondary windings.

The amount of heating depends on both current and resistance.

This is particularly important in step-down transformers. Their secondary windings carry relatively large currents, so even a small winding resistance can produce noticeable heating.

Designers reduce these losses by using suitable conductor thicknesses and materials with low electrical resistance.

There is a trade-off: thicker conductors reduce resistance but require more material, space, and manufacturing cost.

Comparing the three effects

It is useful to keep the mechanisms separate.

MechanismWhat happens?Effect on useful output
Incomplete flux linkageSome magnetic flux does not link both windings.Leakage reactance contributes to voltage drop under load.
Eddy currentsCirculating currents form in the conducting core and nearby metal.Electrical energy is dissipated as heat.
Resistive heatingCurrent flows through resistance in the copper windings.Electrical energy is dissipated as heat.

The distinction between the first mechanism and the other two is important.

Eddy currents and winding resistance directly dissipate real power as heat.

Leakage inductance primarily affects the voltage and current relationships. It can also contribute indirectly to additional heating when its magnetic field induces eddy currents in nearby metal.

Worked example: Calculate the output power of a real transformer

A real transformer receives \(500\,\text{W}\) of electrical input power.

At its operating point, the following losses are measured:

  • Copper losses: \(18\,\text{W}\).
  • Eddy-current losses: \(7\,\text{W}\).
  • Other core losses: \(5\,\text{W}\).

Assume there are no other losses. Calculate the useful output power and efficiency.

Step 1

\[ P_{\mathrm{loss}} = 18+7+5 \]

\[ P_{\mathrm{loss}}=30\,\text{W} \]

Step 2

The input power must equal the useful output power plus the power dissipated through losses.

\[ P_{\mathrm{in}}=P_{\mathrm{out}}+P_{\mathrm{loss}} \]

Rearrange:

\[ P_{\mathrm{out}}=P_{\mathrm{in}}-P_{\mathrm{loss}} \]

Substitute:

\[ P_{\mathrm{out}}=500-30 \]

\[ \boxed{P_{\mathrm{out}}=470\,\text{W}} \]

Step 3

Efficiency is the proportion of input power converted into useful output power.

\[ \eta=\frac{P_{\mathrm{out}}}{P_{\mathrm{in}}}\times100\% \]

\[ \eta=\frac{470}{500}\times100\% \]

\[ \boxed{\eta=94\%} \]

The transformer has an efficiency of 94%.

Notice that the calculation only subtracts actual dissipative losses. We do not subtract another percentage based on the coupling coefficient.

The coefficient of coupling and transformer efficiency describe different physical properties.

06Questions and solutions

The following questions move from standard transformer calculations towards more involved problems that combine coupling, magnetic induction, and energy conservation.

Question 1

A real transformer receives \(600\,\text{W}\) of input power.

At a particular operating point, its measured losses are:

  • Winding heating: \(24\,\text{W}\).
  • Core eddy-current heating: \(9\,\text{W}\).
  • Other core losses: \(7\,\text{W}\).

Assume there are no additional losses.

Calculate:

(a) The useful output power.

(b) The transformer efficiency.

(c) Explain why it would be incorrect to subtract an additional percentage of input power based on the coefficient of coupling.

Solution 1

The transformer delivers \(560\,\text{W}\) of useful output power, with an efficiency of approximately \(93.3\%\).

(a) Output power

First, calculate the total dissipative losses:

\[ P_{\mathrm{loss}}=24+9+7 \]

\[ P_{\mathrm{loss}}=40\,\text{W} \]

Apply conservation of energy:

\[ P_{\mathrm{out}}=P_{\mathrm{in}}-P_{\mathrm{loss}} \]

\[ P_{\mathrm{out}}=600-40 \]

\[ \boxed{P_{\mathrm{out}}=560\,\text{W}} \]

(b) Efficiency

\[ \eta=\frac{P_{\mathrm{out}}}{P_{\mathrm{in}}}\times100\% \]

\[ \eta=\frac{560}{600}\times100\% \]

\[ \boxed{\eta=93.3\%} \]

(c) Why the coupling coefficient is not another power loss

The coupling coefficient measures the strength of magnetic coupling between two coils.

It does not directly measure the proportion of electrical power converted into heat.

Incomplete flux linkage introduces leakage inductance, which influences the voltage available to the load. The magnetic energy associated with leakage flux can be stored and returned to the circuit.

Only actual dissipative mechanisms, such as winding resistance and eddy currents, should be included as direct power losses in the energy balance.

Question 2

Two coupled coils have the following measured inductances:

\[ L_p=0.50\,\text{H} \]

\[ L_s=0.20\,\text{H} \]

Their measured mutual inductance is:

\[ M=0.24\,\text{H} \]

(a) Calculate the coefficient of coupling.

(b) A second measurement, supposedly taken under the same operating conditions without changing the coils, gives \(M=0.34\,\text{H}\).

Determine whether this second measurement is physically consistent with the linear, passive two-coil model. Justify your answer mathematically.

Solution 2

The first measurement gives a coefficient of coupling of approximately \(0.759\). The second measurement is physically inconsistent with the assumed model because it would require a coefficient greater than one.

(a) Calculate the coefficient of coupling

Use:

\[ k=\frac{|M|}{\sqrt{L_pL_s}} \]

Substitute:

\[ k=\frac{0.24}{\sqrt{0.50\times0.20}} \]

\[ k=\frac{0.24}{\sqrt{0.10}} \]

\[ k=\frac{0.24}{0.3162} \]

\[ \boxed{k\approx0.759} \]

The coils have moderate magnetic coupling, with some flux not linking both windings.

(b) Check the second measurement

The second measurement gives:

\[ M=0.34\,\text{H} \]

Calculate the corresponding coefficient:

\[ k=\frac{0.34}{\sqrt{0.50\times0.20}} \]

\[ k=\frac{0.34}{0.3162} \]

\[ k\approx1.075 \]

This is greater than one.

However, the coupling coefficient of two passive coils must satisfy:

\[ k\leq1 \]

The maximum possible mutual inductance for these self-inductances is:

\[ M_{\max}=\sqrt{L_pL_s} \]

\[ M_{\max}=0.3162\,\text{H} \]

The reported value of \(0.34\,\text{H}\) exceeds this limit.

Therefore, the second measurement cannot be correct under the stated assumptions.

Possible explanations include an instrument calibration error, incorrect units, or measurements taken under inconsistent conditions.

The mathematical limit is not an optional design preference. It follows from the physical requirement that a passive magnetic system cannot have more mutual inductance than its self-inductances allow.

Question 3

A pair of coupled coils has:

\[ L_p=0.25\,\text{H} \]

\[ L_s=0.16\,\text{H} \]

\[ k=0.80 \]

The secondary winding is initially open-circuit. At a particular instant, the primary current is changing at a rate of \(15\,\text{A s}^{-1}\).

(a) Calculate the mutual inductance.

(b) Calculate the magnitude of the induced secondary emf.

(c) A resistor is then connected across the secondary while the primary is driven by a fixed AC voltage source. Explain why the secondary terminal voltage cannot automatically be assumed to remain equal to the value calculated in part (b).

Solution 3

The mutual inductance is \(0.16\,\text{H}\), and the initial open-circuit secondary emf is \(2.4\,\text{V}\). Connecting a load changes the circuit behaviour, so the open-circuit result cannot automatically be treated as the loaded terminal voltage.

(a) Calculate mutual inductance

Use:

\[ M=k\sqrt{L_pL_s} \]

Substitute:

\[ M=0.80\sqrt{0.25\times0.16} \]

\[ M=0.80\sqrt{0.040} \]

\[ M=0.80\times0.20 \]

\[ \boxed{M=0.16\,\text{H}} \]

(b) Calculate the induced secondary emf

For an open-circuit secondary:

\[ |\varepsilon_s| = M\left|\frac{\Delta I_p}{\Delta t}\right| \]

Substitute:

\[ |\varepsilon_s|=0.16\times15 \]

\[ \boxed{|\varepsilon_s|=2.4\,\text{V}} \]

(c) Explain the effect of connecting a load

The secondary terminal voltage cannot automatically be assumed to remain at \(2.4\,\text{V}\).

When the resistor is connected, a secondary current begins to flow.

According to Lenz’s law, the magnetic field produced by this current opposes the change in magnetic flux responsible for inducing it.

This affects the primary current drawn from the AC source.

Additionally, the secondary winding has its own self-inductance and electrical resistance, while imperfect coupling introduces leakage reactance.

Consequently, the open-circuit emf calculated in part (b) is no longer sufficient to determine the loaded terminal voltage.

The key assumption that changes is the open-circuit condition: the secondary current is no longer zero.

Question 4

Two transformer designs are compared.

Transformer A has:

  • A laminated iron core.
  • Separate primary and secondary winding sections.

Transformer B has:

  • A solid iron core made from the same magnetic material.
  • Interleaved primary and secondary winding sections.

Both transformers operate at the same frequency and peak magnetic flux density. Assume they have the same core dimensions, winding resistance, and connected load.

(a) Predict how the coefficient of coupling of transformer B compares with that of transformer A.

(b) Predict how the eddy-current losses in transformer B compare with those in transformer A.

(c) Can you conclude which transformer has the higher overall efficiency? Explain why or why not.

Solution 4

Transformer B should have stronger magnetic coupling but greater core eddy-current losses. The overall efficiency cannot be determined from the information given because these changes have competing effects.

(a) Compare the coefficients of coupling

Transformer B has interleaved winding sections.

This arrangement allows the primary and secondary windings to share more of the magnetic flux produced by each other.

Consequently, less flux is likely to link only one winding.

Therefore:

\[ \boxed{k_B>k_A} \]

The improved winding arrangement reduces the relative effect of leakage flux.

(b) Compare eddy-current losses

Transformer A has a laminated core.

The thin insulated sheets interrupt large circulating current paths, reducing eddy currents.

Transformer B has a solid conducting core. Its changing magnetic flux can produce larger circulating current loops.

These currents produce resistive heating within the core.

Therefore:

\[ \boxed{P_{\mathrm{eddy},B}>P_{\mathrm{eddy},A}} \]

under the stated operating conditions.

(c) Compare overall efficiency

There is insufficient information to rank the two transformers.

Transformer B benefits from improved coupling and potentially better voltage regulation.

However, its solid core produces greater eddy-current losses.

The change in coupling can also alter the current drawn by the transformer, affecting its winding losses even though the winding resistances are unchanged.

The total efficiency depends on the relative sizes of these effects.

A student who immediately selects transformer B because it has a higher coupling coefficient is overlooking the additional core heating.

Equally, selecting transformer A simply because it has a laminated core ignores the benefits of improved magnetic coupling.

The correct conclusion is that both designs improve different aspects of transformer performance, and quantitative loss measurements are needed to establish which is more efficient.

Question 5

Two transformer prototypes, A and B, have the same turns ratio and are connected to the same AC supply.

For comparison, their secondary-side equivalent circuits are represented by an ideal \(24.0\,\text{V RMS}\) source in series with an equivalent winding resistance and a leakage reactance. Both supply the same \(12.0\,\Omega\) resistive load.

The following measurements are taken at the same operating point:

PropertyTransformer ATransformer B
Coupling coefficient, \(k\)0.9950.980
Equivalent winding resistance, \(R_{\mathrm{eq}}\)\(0.60\,\Omega\)\(0.10\,\Omega\)
Leakage reactance, \(X_\sigma\)\(0.30\,\Omega\)\(0.60\,\Omega\)
Core losses, \(P_{\mathrm{core}}\)\(5.0\,\text{W}\)\(2.0\,\text{W}\)

The equivalent winding resistance and leakage reactance are both referred to the secondary side.

Assume:

  • Both ideal secondary sources have an RMS voltage of \(24.0\,\text{V}\).
  • The leakage reactance is purely inductive.
  • The stated core losses remain constant at the operating point.
  • The only real power losses are the winding losses and the stated core losses.
  • There are no additional losses.

(a) Calculate the RMS load current for each transformer.

(b) Calculate the useful power delivered to the load by each transformer.

(c) Calculate the efficiency of each transformer.

(d) Determine which transformer performs better under these conditions. Explain why your conclusion does not contradict the relationship between coupling coefficient and leakage flux.

Solution 5

Transformer B delivers more useful power and has the higher efficiency, despite having the lower coefficient of coupling.

The reason is that its winding resistance and core losses are substantially smaller. These advantages outweigh the effect of its greater leakage reactance for the specified load.

(a) Calculate the RMS load currents

The total series impedance magnitude is:

\[ Z=\sqrt{(R_L+R_{\mathrm{eq}})^2+X_\sigma^2} \]

Here, \(R_L\) is the load resistance and \(Z\) is the magnitude of the total impedance.

The RMS current is:

\[ I=\frac{V_0}{Z} \]

where \(V_0=24.0\,\text{V}\) is the ideal secondary source voltage.

For transformer A:

\[ Z_A=\sqrt{(12+0.60)^2+0.30^2} \]

\[ Z_A=\sqrt{158.85} \]

\[ Z_A\approx12.60\,\Omega \]

Therefore:

\[ I_A=\frac{24.0}{12.60} \]

\[ \boxed{I_A\approx1.90\,\text{A}} \]

For transformer B:

\[ Z_B=\sqrt{(12+0.10)^2+0.60^2} \]

\[ Z_B=\sqrt{146.77} \]

\[ Z_B\approx12.11\,\Omega \]

Therefore:

\[ I_B=\frac{24.0}{12.11} \]

\[ \boxed{I_B\approx1.98\,\text{A}} \]

Transformer B supplies the larger load current.

(b) Calculate useful output power

The load is purely resistive, so:

\[ P_{\mathrm{out}}=I^2R_L \]

For transformer A:

\[ P_{\mathrm{out},A} = (1.904)^2\times12 \]

\[ \boxed{P_{\mathrm{out},A}\approx43.5\,\text{W}} \]

For transformer B:

\[ P_{\mathrm{out},B} = (1.981)^2\times12 \]

\[ \boxed{P_{\mathrm{out},B}\approx47.1\,\text{W}} \]

Transformer B delivers approximately \(3.6\,\text{W}\) more useful power.

(c) Calculate efficiency

First, calculate the winding losses.

The equivalent winding resistance has been referred to the secondary, so:

\[ P_{\mathrm{cu}}=I^2R_{\mathrm{eq}} \]

For transformer A:

\[ P_{\mathrm{cu},A} = (1.904)^2\times0.60 \]

\[ P_{\mathrm{cu},A}\approx2.18\,\text{W} \]

Its total input power is:

\[ P_{\mathrm{in},A} = 43.5+2.18+5.0 \]

\[ P_{\mathrm{in},A}\approx50.7\,\text{W} \]

Therefore:

\[ \eta_A=\frac{43.5}{50.7}\times100\% \]

\[ \boxed{\eta_A\approx85.8\%} \]

For transformer B:

\[ P_{\mathrm{cu},B} = (1.981)^2\times0.10 \]

\[ P_{\mathrm{cu},B}\approx0.392\,\text{W} \]

Its total input power is:

\[ P_{\mathrm{in},B} = 47.1+0.392+2.0 \]

\[ P_{\mathrm{in},B}\approx49.5\,\text{W} \]

Therefore:

\[ \eta_B=\frac{47.1}{49.5}\times100\% \]

\[ \boxed{\eta_B\approx95.2\%} \]

(d) Explain the result

Transformer A has a higher coefficient of coupling:

\[ k_A=0.995>k_B=0.980 \]

This means A has stronger relative magnetic coupling.

It also has a smaller measured leakage reactance, which helps reduce the voltage drop associated with leakage inductance.

However, A has much greater winding resistance and core losses.

Transformer B has lower winding resistance, so substantially less power is converted into heat within its copper windings. Its core losses are also smaller.

Although B has greater leakage reactance, the effect on the current is not large enough to outweigh its lower resistive and core losses.

The final comparison is:

PropertyTransformer ATransformer B
Load power\(43.5\,\text{W}\)\(47.1\,\text{W}\)
Total input power\(50.7\,\text{W}\)\(49.5\,\text{W}\)
Efficiency\(85.8\%\)\(95.2\%\)

The important conclusion is that a higher coupling coefficient does not guarantee higher transformer efficiency.

The coefficient measures magnetic coupling, while efficiency depends on the complete balance of useful output power and real power losses.

Also notice that the coupling coefficient alone does not determine the absolute leakage reactance. The self-inductances and operating frequency matter too, which is why the equivalent-circuit measurements were supplied separately.

This is the conceptual difference between a transformer that transfers magnetic energy effectively and one that converts a large proportion of its input electrical power into useful output.

07Where to go next

Coupling coefficients provide a more precise way to describe the magnetic relationship between transformer windings.

They also introduce an important engineering distinction: improving magnetic coupling does not automatically eliminate resistive or core losses.

The next useful step is understanding the transformer equivalent circuit. This represents leakage inductance, winding resistance, and core losses as separate circuit elements, allowing you to predict how a real transformer behaves under different loads.

Two related concepts are particularly useful:

Technical references

The physical models and relationships discussed in this extension are consistent with the following university and syllabus resources: