Mutual Inductance: How Changing Current Induces an EMF

Learn how a changing current in one coil induces an emf in another through mutual inductance. Explore the physics behind transformers, derive the key equations, and practise with progressively challenging worked examples and HSC extension questions.

Connect a battery to the primary coil of a transformer. The instant you close the switch, a voltmeter connected across the secondary coil registers a voltage. Leave the switch closed, and the reading falls back to zero, even though current is still flowing through the primary.

Now replace the battery with an AC supply. The secondary develops a continuous alternating voltage.

The difference is the changing magnetic field. Electromagnetic induction requires a change in magnetic flux, not simply the presence of a magnetic field. But there is a more precise way to describe how effectively one coil induces an emf in another.

This is where mutual inductance comes in.

Mutual inductance is an extension beyond the required content of the 2025 NSW Physics 11-12 syllabus. The electromagnetic induction concepts from Year 12 provide the foundation, but the quantitative treatment of mutual inductance developed here is additional physics, not an extra HSC assessment requirement.

01Why does a transformer need an AC input?

Start with two coils of wire, called the primary and secondary coils. Both are wound around a shared iron core.

The primary coil is connected to an electrical supply. The secondary coil is connected to an external circuit, such as a lamp.

Cutaway transformer showing a laminated rectangular iron core, primary and secondary coils on opposite limbs, an AC voltage source, a connected lamp, and magnetic flux circulating through the shared core.
Alternating current in the primary reverses magnetic flux around the shared iron core, inducing an alternating emf that powers the secondary lamp.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

When current flows through the primary coil, it produces a magnetic field. The iron core guides this field around the transformer, allowing magnetic flux to pass through the secondary coil.

If the magnetic flux through the secondary changes, an emf is induced.

This is described by Faraday’s law:

\[ \varepsilon_s=-N_s\frac{\Delta\Phi_s}{\Delta t} \]

Where:

  • \(\varepsilon_s\) is the induced emf in the secondary, measured in volts (V).
  • \(N_s\) is the number of turns in the secondary coil.
  • \(\Delta\Phi_s\) is the change in magnetic flux through one turn, measured in webers (Wb).
  • \(\Delta t\) is the time interval over which the change occurs, measured in seconds (s).

The negative sign represents Lenz’s law: the induced emf acts in a direction that opposes the change in magnetic flux.

If the primary receives an AC supply, its current and magnetic field continuously change. Consequently, the magnetic flux through the secondary also changes, producing an alternating emf.

If the secondary circuit is closed, this emf drives an alternating current through the load.

What happens if we replace the AC supply with a DC battery?

When the battery is first connected, the primary current increases from zero. This produces a changing magnetic field, so the secondary experiences a brief induced emf.

However, once the primary current reaches a steady value, its magnetic field becomes constant. The magnetic flux through the secondary stops changing, and the induced emf disappears.

The same happens when the battery is disconnected, except that the collapsing magnetic field produces an emf in the opposite direction.

This reveals an important distinction:

  • AC produces continuously changing magnetic flux, allowing continuous AC output.
  • Steady DC produces constant magnetic flux after the initial switching transient, so there is no sustained secondary emf.
  • Switched or pulsed DC can also produce induction, but not the continuous alternating output of a conventional transformer.

Strictly speaking, a transformer requires changing magnetic flux, not AC specifically. AC is the practical way to maintain that change continuously.

02From magnetic flux to mutual inductance

We can now consider the mechanism more closely.

Imagine two coils placed close together. The first coil carries a current, producing a magnetic field. Some of this field passes through the second coil.

Suppose the current in the primary increases.

The magnetic field becomes stronger, and more magnetic flux passes through the secondary. This produces an induced emf in the secondary.

If the primary current decreases, the magnetic field weakens, and the induced emf reverses direction.

The important point is that the secondary responds to the change in magnetic flux produced by the primary current.

We can quantify how effectively the primary produces magnetic flux through the secondary.

Flux linkage

A single turn of wire experiences magnetic flux, represented by \(\Phi\).

However, a coil contains multiple turns. If every turn experiences the same magnetic flux, the total flux linkage is:

\[ \lambda=N\Phi \]

Where:

  • \(\lambda\) is the total magnetic flux linkage, measured in webers (Wb-turns).
  • \(N\) is the number of turns in the coil.
  • \(\Phi\) is the magnetic flux through one turn, measured in webers.

For the secondary coil, we are interested specifically in the flux produced by the primary current.

Let:

  • \(I_p\) be the current in the primary coil.
  • \(N_s\) be the number of turns in the secondary coil.
  • \(\Phi_{sp}\) be the magnetic flux through one secondary turn produced by the primary coil.

The secondary flux linkage due to the primary is therefore:

\[ \lambda_{sp}=N_s\Phi_{sp} \]

Defining mutual inductance

In a fixed arrangement of coils, with a linear magnetic material, increasing the primary current increases the magnetic field proportionally.

This means the magnetic flux linkage in the secondary is also proportional to the primary current.

We can express this relationship using a constant called the mutual inductance, represented by \(M\).

\[ \boxed{M=\frac{N_s\Phi_{sp}}{I_p}} \]

Or, more simply:

\[ \boxed{M=\frac{\lambda_{sp}}{I_p}} \]

Mutual inductance measures how effectively a current in one coil produces magnetic flux linkage in another coil.

Its SI unit is the henry (H).

\[ 1\text{ H}=1\frac{\text{V}\cdot\text{s}}{\text{A}} \]

A mutual inductance of 1 H means that a primary current changing at 1 A/s produces a mutual induced emf of 1 V in the secondary, assuming the mutual inductance remains constant.

What determines the value of M?

Mutual inductance depends on the physical arrangement of the two coils.

Important factors include:

  • Number of turns: More turns in either coil can increase the flux linkage.
  • Distance between coils: Greater separation generally reduces the amount of magnetic flux linking both coils.
  • Orientation: Coils positioned to intercept more of the same magnetic flux generally have stronger mutual coupling.
  • Core material: A suitable magnetic core can concentrate magnetic flux and increase mutual inductance.
  • Coil geometry: The shape and cross-sectional area of the coils affect how much magnetic flux they share.

For a fixed arrangement with a linear magnetic core, \(M\) is constant and does not depend on the instantaneous current.

Real magnetic materials can become saturated, however, meaning their response is no longer proportional to current. In that situation, treating \(M\) as constant becomes an approximation.

03Calculating the induced emf using mutual inductance

We now have a way to describe how much magnetic flux linkage is produced by a particular primary current.

The next step is to connect this to Faraday’s law.

Recall:

\[ \varepsilon_s=-\frac{\Delta\lambda_{sp}}{\Delta t} \]

For a fixed coil arrangement with constant mutual inductance:

\[ \lambda_{sp}=MI_p \]

Substituting:

\[ \varepsilon_s=-\frac{\Delta(MI_p)}{\Delta t} \]

Since \(M\) is constant:

\[ \boxed{\varepsilon_s=-M\frac{\Delta I_p}{\Delta t}} \]

This is the central equation for mutual inductance.

It tells us that the induced emf in the secondary depends on two things:

  1. The mutual inductance between the coils.
  2. The rate of change of current in the primary coil.

For a uniform current change, this gives the average induced emf over the interval. For an instantaneous emf, the corresponding expression uses the instantaneous rate of change:

\[ \varepsilon_s=-M\frac{dI_p}{dt} \]

The symbol \(dI_p/dt\) represents the instantaneous rate at which primary current changes.

Why the rate of change matters more than the current itself

Consider two situations.

Situation A: The primary carries a large, constant current of 5 A.

Situation B: The primary carries a smaller current that increases rapidly from 0 A to 2 A.

Which situation produces the larger secondary emf?

Situation B can produce the larger emf, despite having a smaller current.

Why? Because the secondary responds to how quickly the magnetic flux changes, not simply how strong the magnetic field currently is.

A large, constant magnetic field produces no induced emf. A smaller magnetic field that changes rapidly can produce a substantial emf.

This is the most important distinction to remember when applying the mutual inductance equation.

Worked example: A changing current in the primary coil

Two coils have a mutual inductance of 0.12 H. The current in the primary coil increases uniformly from 0.50 A to 2.0 A over 0.030 s.

Calculate the magnitude of the average emf induced in the secondary coil.

Step 1

\[ |\varepsilon_s|=M\frac{|\Delta I_p|}{\Delta t} \]

We use the magnitude because the question asks for the size of the induced emf.

Step 2

\[ \Delta I_p=2.0-0.50=1.50\text{ A} \]

Step 3

\[ \frac{\Delta I_p}{\Delta t} =\frac{1.50}{0.030} =50\text{ A/s} \]

Step 4

\[ |\varepsilon_s|=0.12\times50 \]

\[ \boxed{|\varepsilon_s|=6.0\text{ V}} \]

The average induced emf is 6.0 V.

Because the primary current is increasing, the secondary’s induced current, if its circuit is closed, will produce a magnetic field opposing the increase in primary flux. This is consistent with Lenz’s law.

Notice that the answer depends on the rate of change of current, rather than its final value of 2.0 A.

04Calculating mutual inductance from coil geometry

So far, we have treated mutual inductance as a supplied quantity.

But can we calculate \(M\) from the physical properties of the coils?

Yes. Consider a long solenoid surrounded by a second coil.

The primary solenoid has:

  • \(N_p\) turns.
  • Length \(\ell\).
  • Cross-sectional area \(A_p\).
  • Current \(I_p\).

The secondary coil has \(N_s\) turns and surrounds the primary solenoid.

For a sufficiently long air-core solenoid, the magnetic field inside is approximately uniform and is given by:

\[ B_p=\mu_0\frac{N_p}{\ell}I_p \]

Where:

  • \(B_p\) is the magnetic field produced by the primary, measured in teslas (T).
  • \(\mu_0\) is the permeability of free space, equal to \(4\pi\times10^{-7}\text{ H/m}\).
  • \(N_p\) is the number of primary turns.
  • \(\ell\) is the primary solenoid’s length, measured in metres.
  • \(I_p\) is the primary current, measured in amperes.

Because the magnetic field is approximately uniform inside the primary solenoid, the magnetic flux through each secondary turn is:

\[ \Phi_{sp}=B_pA_p \]

Substituting the solenoid field equation:

\[ \Phi_{sp} =\mu_0\frac{N_pI_p}{\ell}A_p \]

The mutual inductance is:

\[ M=\frac{N_s\Phi_{sp}}{I_p} \]

Substituting the expression for flux:

\[ M=\frac{N_s}{I_p} \left(\mu_0\frac{N_pI_pA_p}{\ell}\right) \]

The primary current cancels:

\[ \boxed{M=\frac{\mu_0N_pN_sA_p}{\ell}} \]

This equation shows how the geometry of the two coils determines their mutual inductance under the stated assumptions.

It assumes:

  • The primary is a sufficiently long solenoid.
  • The core is air.
  • The magnetic field outside the primary solenoid is negligible.
  • All primary magnetic flux links every secondary turn.
  • The coils remain stationary.

It is not a general equation for every transformer.

Worked example: Mutual inductance of two concentric coils

A long air-core primary solenoid has 800 turns, a length of 0.40 m, and a cross-sectional area of \(2.0\times10^{-4}\text{ m}^2\).

A secondary coil with 200 turns surrounds the primary solenoid. Assume that every secondary turn links the entire magnetic flux inside the primary solenoid.

The primary current increases uniformly from 0 A to 3.0 A in 0.015 s.

Calculate:

(a) The mutual inductance of the two coils.

(b) The magnitude of the average emf induced in the secondary.

Step 1

\[ M=\frac{\mu_0N_pN_sA_p}{\ell} \]

We are given:

  • \(N_p=800\)
  • \(N_s=200\)
  • \(A_p=2.0\times10^{-4}\text{ m}^2\)
  • \(\ell=0.40\text{ m}\)

Step 2

\[ M= \frac{ (4\pi\times10^{-7})(800)(200) (2.0\times10^{-4}) }{0.40} \]

\[ \boxed{M=1.01\times10^{-4}\text{ H}} \]

The mutual inductance is approximately 0.10 mH.

Step 3

\[ \frac{\Delta I_p}{\Delta t} =\frac{3.0-0}{0.015} \]

\[ =200\text{ A/s} \]

Step 4

\[ |\varepsilon_s| =M\frac{|\Delta I_p|}{\Delta t} \]

\[ =(1.01\times10^{-4})(200) \]

\[ \boxed{|\varepsilon_s|=0.020\text{ V}} \]

Or:

\[ \boxed{|\varepsilon_s|=20\text{ mV}} \]

The secondary experiences an average induced emf of approximately 20 mV.

The result is relatively small because the calculated mutual inductance is small. Increasing the number of turns or using a suitable magnetic core could increase the mutual inductance.

One important restriction: this calculation uses an air-core model. An iron core changes the magnetic field substantially, and its permeability may vary with magnetic field strength. The simple expression involving \(\mu_0\) cannot simply be applied to every iron-core transformer.

05When the mutual inductance is not constant

There is one more layer worth understanding.

So far, we have assumed that the two coils remain stationary and their magnetic properties stay constant.

But what happens if we physically move one coil?

As the coils move further apart, less magnetic flux from the primary may pass through the secondary. Even if the primary current remains constant, the magnetic flux linkage in the secondary can change.

This means an emf can be induced without changing the primary current.

The more general relationship is:

\[ \boxed{\varepsilon_s=-\frac{d(MI_p)}{dt}} \]

Expanding the expression:

\[ \boxed{ \varepsilon_s =-M\frac{dI_p}{dt} -I_p\frac{dM}{dt} } \]

The second term accounts for changes in the mutual inductance itself.

For a finite time interval, we can use:

\[ \boxed{ \bar{\varepsilon}_s =-\frac{\Delta(MI_p)}{\Delta t} } \]

This is simply Faraday’s law applied to the changing flux linkage.

There are now two possible causes of induced emf:

  • The primary current changes while the coil arrangement remains fixed.
  • The mutual inductance changes because the physical arrangement or magnetic properties change.

Both affect the magnetic flux linkage in the secondary.

This distinction becomes particularly important when studying moving coils and real electromagnetic systems.

06Sources and further reading

The physics and mathematical models in this extension are consistent with the following educational and authoritative references:

07Questions and solutions

The following questions progress from straightforward applications of the mutual inductance equation to situations where multiple effects must be considered.

Question 1

Two stationary coils have a mutual inductance of 0.075 H.

The current in the primary coil increases uniformly from 0.40 A to 1.60 A over 0.030 s.

Calculate:

(a) The magnitude of the average emf induced in the secondary coil.

(b) The direction of the induced current in the secondary relative to the change in primary magnetic flux.

Solution 1

(a) The average induced emf is 3.0 V. (b) The induced current produces a magnetic field opposing the increase in primary magnetic flux.

We first calculate the rate of change of primary current.

\[ \Delta I_p=1.60-0.40 =1.20\text{ A} \]

\[ \frac{\Delta I_p}{\Delta t} =\frac{1.20}{0.030} =40\text{ A/s} \]

Using the mutual inductance equation:

\[ |\varepsilon_s| =M\frac{|\Delta I_p|}{\Delta t} \]

\[ =(0.075)(40) \]

\[ \boxed{|\varepsilon_s|=3.0\text{ V}} \]

For part (b), the primary current is increasing, so the magnetic field it produces is becoming stronger.

According to Lenz’s law, the induced current in the secondary must produce a magnetic field that opposes this increase.

It does not oppose the existence of the primary magnetic field. It opposes the change in that field.

Question 2

A pair of fixed coils has a mutual inductance of 0.080 H.

The current in the primary coil varies sinusoidally according to:

\[ I_p(t)=1.8\sin(2\pi 50t) \]

where \(I_p\) is measured in amperes and \(t\) is measured in seconds.

Calculate:

(a) The maximum magnitude of the emf induced in the secondary.

(b) The induced emf at the instant when the primary current reaches its maximum positive value.

(c) Explain why the maximum primary current does not produce the maximum secondary emf.

Solution 2

(a) The maximum induced emf is 45.2 V. (b) The induced emf is zero when the primary current reaches its positive maximum.

(a) Calculate the maximum induced emf.

The current has the form:

\[ I_p=I_0\sin(2\pi ft) \]

Where:

  • \(I_0=1.8\text{ A}\) is the peak current.
  • \(f=50\text{ Hz}\) is the frequency.
  • \(t\) is time.

The instantaneous induced emf is:

\[ \varepsilon_s=-M\frac{dI_p}{dt} \]

Differentiating the sinusoidal current gives:

\[ \frac{dI_p}{dt} =2\pi fI_0\cos(2\pi ft) \]

The maximum magnitude occurs when the cosine term has magnitude 1.

Therefore:

\[ |\varepsilon_s|_{\max}=2\pi fMI_0 \]

Substituting:

\[ |\varepsilon_s|_{\max} =2\pi(50)(0.080)(1.8) \]

\[ \boxed{|\varepsilon_s|_{\max}=45.2\text{ V}} \]

(b) Determine the emf at maximum primary current.

The primary current reaches its positive maximum when:

\[ \sin(2\pi ft)=1 \]

At this instant:

\[ \cos(2\pi ft)=0 \]

Therefore:

\[ \boxed{\varepsilon_s=0\text{ V}} \]

(c) Explain the result.

The tempting prediction is that the largest primary current should produce the largest secondary emf.

However, the secondary responds to the rate of change of primary current, not its magnitude.

At the maximum primary current, the current is momentarily stationary before beginning to decrease. Its instantaneous rate of change is zero.

Consequently, the induced emf is also zero.

The largest induced emf occurs when the primary current passes through zero, because that is where its rate of change is greatest.

This is a useful distinction between the strength of a magnetic field and how rapidly that field changes.

Question 3

A primary coil is connected to a DC battery through a switch. A secondary coil is connected to a sensitive voltmeter.

The coils are stationary and magnetically coupled.

The switch is initially open. It is then closed and left closed for several seconds before being opened again.

Describe the voltmeter reading:

(a) Immediately after the switch is closed.

(b) While the switch remains closed and the primary current is steady.

(c) Immediately after the switch is opened.

Explain why the two brief voltmeter deflections occur in opposite directions.

Solution 3

The voltmeter briefly deflects when the switch is closed, returns to zero while the switch remains closed, and briefly deflects in the opposite direction when the switch is opened.

(a) Immediately after closing the switch

The primary current increases from zero towards its steady value.

This creates an increasing magnetic field, so the magnetic flux through the secondary changes.

Faraday’s law predicts an induced emf, producing a brief voltmeter deflection.

(b) While the switch remains closed

After the initial transient, the primary current becomes constant.

The magnetic field and magnetic flux through the secondary are now constant.

Therefore:

\[ \frac{\Delta\Phi}{\Delta t}=0 \]

And:

\[ \boxed{\varepsilon_s=0} \]

The voltmeter returns to zero.

(c) Immediately after opening the switch

The primary current rapidly decreases towards zero.

The magnetic field collapses, causing the magnetic flux through the secondary to decrease.

An emf is induced again, but this time its polarity is opposite to the initial deflection.

Why do the directions reverse?

Lenz’s law explains both deflections.

When the switch closes, the secondary opposes the increase in magnetic flux.

When the switch opens, the secondary opposes the decrease in magnetic flux.

The two changes in flux have opposite directions, so the induced emf also reverses.

This experiment demonstrates why a transformer cannot produce a sustained output from an ordinary steady DC supply.

Question 4

Two coils, A and B, are wound around a shared linear magnetic core.

Their positive current reference directions are chosen so that positive current in either coil produces magnetic flux in the same direction through the core.

The following values are known:

  • Mutual inductance: \(M=0.050\text{ H}\).
  • Self-inductance of coil B: \(L_B=0.20\text{ H}\).
  • Rate of change of current in coil A: \(dI_A/dt=+12\text{ A/s}\).
  • Rate of change of current in coil B: \(dI_B/dt=-4\text{ A/s}\).

Calculate the total induced emf in coil B due to its own changing current and the changing current in coil A.

Ignore resistance and any externally applied voltage.

Solution 4

The total induced emf in coil B is +0.20 V in the chosen reference polarity.

The important detail is that coil B experiences two separate induction effects:

  1. Self-induction caused by its own changing current.
  2. Mutual induction caused by the changing current in coil A.

These effects must be added with their signs.

Step 1: Calculate the self-induced emf in coil B.

The self-induction equation is:

\[ \varepsilon_{\text{self}} =-L_B\frac{dI_B}{dt} \]

Substituting:

\[ \varepsilon_{\text{self}} =-(0.20)(-4) \]

\[ \boxed{\varepsilon_{\text{self}}=+0.80\text{ V}} \]

The positive result means that self-induction acts to oppose the decrease in current in coil B.

Step 2: Calculate the mutually induced emf in coil B.

The mutual induction equation is:

\[ \varepsilon_{\text{mutual}} =-M\frac{dI_A}{dt} \]

Substituting:

\[ \varepsilon_{\text{mutual}} =-(0.050)(12) \]

\[ \boxed{\varepsilon_{\text{mutual}}=-0.60\text{ V}} \]

The negative result means that the emf induced by coil A acts opposite to the positive reference direction in coil B.

Step 3: Calculate the total induced emf.

The two contributions add algebraically:

\[ \varepsilon_B =\varepsilon_{\text{self}} +\varepsilon_{\text{mutual}} \]

\[ =0.80-0.60 \]

\[ \boxed{\varepsilon_B=+0.20\text{ V}} \]

Why is the answer not simply -0.60 V?

Using only the mutual inductance equation would ignore the magnetic field produced by coil B itself.

Coil B is also experiencing self-induction because its own current is changing.

The two induced emfs act in opposite directions, so they partially cancel.

This illustrates why it is important to distinguish mutual induction from self-induction when analysing coupled coils.

Question 5

Two coils are mounted on a shared magnetic core. The primary coil carries a current that increases uniformly from 1.0 A to 3.0 A over 0.20 s.

At the same time, the secondary coil is moved along the core, causing the mutual inductance to decrease uniformly from 0.12 H to 0.040 H.

Assume:

  • The relative winding orientation remains unchanged.
  • Both the primary current and mutual inductance vary linearly with time.
  • The coils remain magnetically coupled throughout the movement.

Calculate:

(a) The average induced emf in the secondary over the complete 0.20 s interval.

(b) The average induced emf during the first 0.10 s.

(c) The average induced emf during the second 0.10 s.

(d) Explain why the statement “the primary current is increasing, so the secondary emf must have the same polarity throughout” is incorrect.

Solution 5

The average emf over the complete interval is zero, but the induced emf is not zero throughout. It averages -0.40 V during the first half and +0.40 V during the second half.

This question tests an important limitation of the simpler mutual inductance equation.

The expression:

\[ \varepsilon_s=-M\frac{dI_p}{dt} \]

assumes that \(M\) remains constant.

Here, both the primary current and the mutual inductance change. We must therefore consider the total magnetic flux linkage.

Step 1: Calculate the initial flux linkage.

The flux linkage is:

\[ \lambda_{sp}=MI_p \]

Initially:

\[ \lambda_i=(0.12)(1.0) \]

\[ \boxed{\lambda_i=0.12\text{ Wb-turns}} \]

Step 2: Calculate the final flux linkage.

At the end of the interval:

\[ \lambda_f=(0.040)(3.0) \]

\[ \boxed{\lambda_f=0.12\text{ Wb-turns}} \]

The initial and final flux linkages are identical.

Step 3: Calculate the average emf over the complete interval.

Using Faraday’s law:

\[ \bar{\varepsilon}_s =-\frac{\Delta\lambda_{sp}}{\Delta t} \]

\[ =-\frac{0.12-0.12}{0.20} \]

\[ \boxed{\bar{\varepsilon}_s=0\text{ V}} \]

However, this does not mean that no emf was induced during the interval.

To see why, we need to examine what happens halfway through.

Step 4: Calculate the flux linkage at the midpoint.

Because both quantities change linearly, after 0.10 s:

\[ I_p=2.0\text{ A} \]

And:

\[ M=0.080\text{ H} \]

Therefore:

\[ \lambda_{\text{mid}}=(0.080)(2.0) \]

\[ \boxed{\lambda_{\text{mid}}=0.16\text{ Wb-turns}} \]

The flux linkage has increased from 0.12 to 0.16 Wb-turns during the first half.

Step 5: Calculate the average emf during the first half.

\[ \bar{\varepsilon}_1 =-\frac{\lambda_{\text{mid}}-\lambda_i}{0.10} \]

\[ =-\frac{0.16-0.12}{0.10} \]

\[ \boxed{\bar{\varepsilon}_1=-0.40\text{ V}} \]

Step 6: Calculate the average emf during the second half.

During the second half, flux linkage decreases from 0.16 to 0.12 Wb-turns.

\[ \bar{\varepsilon}_2 =-\frac{\lambda_f-\lambda_{\text{mid}}}{0.10} \]

\[ =-\frac{0.12-0.16}{0.10} \]

\[ \boxed{\bar{\varepsilon}_2=+0.40\text{ V}} \]

The induced emf reverses its average polarity between the two halves.

Step 7: Explain the physical result.

The tempting prediction is that an increasing primary current must always produce an induced emf of the same polarity.

That prediction assumes the mutual inductance is constant.

But in this question, the secondary is moving away from the primary. As the coils become less strongly coupled, the mutual inductance decreases.

The relevant quantity is not the primary current by itself. It is the product:

\[ \boxed{\lambda_{sp}=MI_p} \]

During the first half, the increase in primary current dominates, so the flux linkage increases.

During the second half, the reduction in mutual inductance dominates, so the flux linkage decreases.

At the midpoint, the two effects momentarily balance, and the instantaneous induced emf is zero.

The overall average emf is also zero because the initial and final flux linkages are identical. But there has still been a changing flux linkage throughout the process.

This is the deeper principle: electromagnetic induction responds to changes in magnetic flux linkage, not to changes in current alone.


08Where to take this next

Mutual inductance gives us a way to quantify how effectively two coils exchange magnetic flux.

However, real transformers do not have perfect magnetic coupling. Some of the magnetic flux produced by the primary never passes through the secondary.

The next useful concept is the coupling coefficient, which measures how effectively the magnetic flux produced by one coil links the other.

Continue with Coupling Coefficients: Magnetic Flux Linkage in Real Transformers.

It builds directly on mutual inductance and explains why the ideal transformer model differs from a real transformer.