Stepper Motors: How Sequenced Magnetic Fields Control Motion

Learn how stepper motors produce precise angular movements by sequencing electromagnetic fields. Explore how back emf, winding inductance, and load torque limit speed, cause missed steps, and affect microstepping accuracy.

Suppose a controller sends 50 pulses to a stepper motor rated at 1.8° per full step. It expects the shaft to rotate exactly 90°. But if the motor is carrying too much weight, or the pulses arrive too quickly, the shaft might finish short of its target even though the controller sent every pulse.

How can a motor move through precise angular increments without a position sensor? And why can it sometimes fail to follow its own instructions?

A stepper motor solves the positioning problem by moving its magnetic field in a carefully controlled sequence. The rotor follows that changing field, advancing through discrete angular positions rather than simply spinning continuously.

The important catch is that the rotor must keep up with the changing field. If it cannot, it can miss steps.

Scope: Stepper motor operation is an extension beyond the required NSW HSC Physics syllabus. This article assumes you understand the Year 12 Electromagnetism model of a simple DC motor, including back emf. That material is the prerequisite, not an indication that stepper motors are an HSC assessment requirement.

01Start with the DC motor: why does current change with speed?

Before looking at stepper motors, recall something interesting about a simple DC motor.

When you first connect a stationary motor to a battery, its current is relatively large. As the motor speeds up, the current decreases, even though the battery voltage hasn’t changed.

Why?

The explanation is back emf.

When a motor’s armature rotates inside a magnetic field, its conductors experience electromagnetic induction. The resulting induced voltage opposes the applied supply voltage, in accordance with Lenz’s law.

This opposing voltage is called the back electromotive force, or back emf.

Brushed DC motor cross-section showing N and S permanent-magnet stator poles, a rotating wound armature, shaft, split-ring commutator and brushes. Beside it, an equivalent series circuit identifies the DC supply, armature resistance, current and opposing back emf, with a graph showing back emf increasing and current decreasing with rotational speed.
As the armature spins, induced back emf rises against the supply, so the current through its resistance falls.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The relationship between back emf and current

Consider a simple DC motor connected to a constant voltage supply.

At the instant it starts, the rotor is stationary. There is no rotational back emf because the armature isn’t moving.

The supply voltage therefore drives current through the armature resistance.

As the motor accelerates, its back emf increases. This reduces the net voltage driving current through the armature.

For a simplified steady-state model:

\[ V=E_b+IR \]

Rearranging:

\[ I=\frac{V-E_b}{R} \]

Where:

  • \(V\) is the applied supply voltage, measured in volts (V).
  • \(E_b\) is the back emf, measured in volts (V).
  • \(I\) is the armature current, measured in amperes (A).
  • \(R\) is the armature resistance, measured in ohms (\(\Omega\)).

For a motor with constant magnetic field strength, back emf is proportional to angular speed:

\[ E_b=k_e\omega \]

Here:

  • \(k_e\) is the motor’s back-emf constant, measured in V s rad\(^{-1}\).
  • \(\omega\) is the angular velocity of the rotor, measured in rad s\(^{-1}\).

The constant \(k_e\) depends on the motor’s construction and magnetic field strength.

These equations give us an important prediction.

  • At startup, \(\omega=0\), so \(E_b=0\). Current is at its maximum in this simplified model.
  • As speed increases, back emf increases and current decreases.
  • If the motor slows down under an increased load, back emf decreases and current increases.

That final point is particularly useful.

The increased current produces greater electromagnetic torque, assuming the magnetic field remains constant. The motor can therefore respond to a heavier load by drawing more current.

This doesn’t mean it can handle any load. If the required torque becomes too large, the motor will eventually stall.

The model above assumes steady current and ignores armature inductance, brush voltage drops, and changes in winding resistance due to heating. Real motor behaviour is more complicated, particularly during startup.

Worked example: back emf when a motor slows down

A brushed DC motor operates from a 12 V supply. Its armature resistance is 2.0 Ω, and it draws 1.5 A while running steadily.

The load increases, causing the motor’s angular speed to fall to 60% of its original value.

Assuming constant magnetic field strength, calculate the new armature current.

Step 1

Using the steady-state motor equation:

\[ E_b=V-IR \]

Substitute the given values:

\[ E_b=12-(1.5)(2.0) \]

\[ E_b=9.0\text{ V} \]

Step 2

Back emf is proportional to angular speed when the magnetic field remains constant.

The new speed is 60% of the original speed, so:

\[ E_{b,\text{new}}=0.60(9.0) \]

\[ E_{b,\text{new}}=5.4\text{ V} \]

Step 3

\[ I=\frac{V-E_b}{R} \]

\[ I=\frac{12-5.4}{2.0} \]

\[ \boxed{I=3.3\text{ A}} \]

The current increases from 1.5 A to 3.3 A.

This is a substantial increase in current, allowing the motor to produce greater torque to oppose the increased load.

Notice the sequence:

\[ \text{Load increases} \]

\[ \Downarrow \]

\[ \text{Speed decreases} \]

\[ \Downarrow \]

\[ \text{Back emf decreases} \]

\[ \Downarrow \]

\[ \text{Current and torque increase} \]

This is the foundation we need. Now we can look at a motor that uses a different method to control its rotation.

02How a stepper motor produces discrete angular motion

A conventional DC motor is designed to rotate continuously. Its commutator changes the armature connections as the rotor turns, allowing the motor to maintain torque in the same rotational direction.

A stepper motor works differently.

Instead of relying on continuous mechanical rotation and commutation, it uses electronically controlled electromagnets arranged around a rotor.

The two main components are:

  • Stator: The stationary outer section containing electromagnets and their windings.
  • Rotor: The central rotating section, which responds to the magnetic fields produced by the stator.

We will focus on a common design called a hybrid stepper motor. It combines a permanent-magnet rotor with toothed iron sections, allowing it to achieve many closely spaced stable positions.

Why does the rotor move?

Imagine holding a compass near a magnet.

The compass needle turns to align with the magnetic field. If you move the magnet, the needle attempts to follow.

A stepper motor uses a related principle.

Its stator contains coils of wire arranged into groups called phases. When current flows through a phase, it produces a magnetic field.

The rotor experiences magnetic forces that encourage it to align with the stator’s magnetic field.

The driver can change the direction of current through the windings, reversing the magnetic poles. It can also energise different phases in sequence.

Each change shifts the preferred magnetic alignment of the rotor.

The rotor therefore moves towards a new stable angular position.

The compass analogy is useful, but incomplete. A real rotor has mass and rotational inertia. It doesn’t instantly follow a changing magnetic field. Its movement is governed by electromagnetic torque, friction, and the load attached to its shaft.

Sequencing the stator windings

Consider a simplified two-phase stepper motor.

Its two winding phases are called A and B. Their magnetic axes are separated by 90 electrical degrees.

The direction of current through each phase determines the polarity of its magnetic field.

For example:

  • A positive current through phase A creates one magnetic orientation.
  • Reversing the current through A reverses that phase’s magnetic polarity.
  • The same applies to phase B.

The motor driver controls these current directions in a repeating sequence. This process is called commutation.

For a two-phase, two-phase-on full-step drive, one possible sequence is:

StepPhase A currentPhase B currentResultant magnetic field direction
1+I+I45°
2−I+I135°
3−I−I225°
4+I−I315°
5+I+I45°

Here, \(I\) represents the equal current magnitude in each phase. The positive and negative signs indicate opposite current directions relative to the chosen winding connections.

Notice what happens.

Each successive electrical state rotates the resultant magnetic field by 90 electrical degrees in the simplified model.

The rotor attempts to align with each new field direction. As the driver continues through the sequence, the rotor advances around the motor.

Reversing the order of the sequence reverses the direction of rotation.

An important distinction: The 90-degree changes above describe the magnetic field in a simplified electrical model. They do not mean that the actual motor shaft rotates by 90 degrees per command. Real hybrid stepper motors have multiple rotor and stator teeth, producing much smaller mechanical increments.

Why are the actual steps so small?

The rotor and stator contain carefully arranged magnetic poles and teeth.

These teeth create numerous possible alignment positions around the rotor. Changing the stator’s magnetic field shifts which alignment is preferred.

A common hybrid stepper motor has 200 full steps per revolution.

Its angular displacement per full step is therefore:

\[ \theta_s=\frac{360^\circ}{N} \]

Where:

  • \(\theta_s\) is the full-step angle, measured in degrees.
  • \(N\) is the number of full steps per revolution.

For a 200-step motor:

\[ \theta_s=\frac{360^\circ}{200} \]

\[ \boxed{\theta_s=1.8^\circ} \]

Every successful full-step command therefore rotates the shaft by 1.8°.

This is how a motor can make very small, controlled angular movements without needing a mechanical commutator.

03Controlling position and speed using pulses

The stepper motor is controlled by a combination of a controller and a motor driver.

The controller generates electrical pulse commands. The driver interprets these commands and supplies the required current to the stator windings.

Three features of the commands determine the intended motion:

Control featureEffect on motor
Number of pulsesDetermines the commanded angular displacement
Pulse frequencyDetermines the commanded rotational speed
Phase sequenceDetermines the direction of rotation

Let’s look at each relationship.

Angular displacement

If the motor completes one mechanical step for every full-step pulse, its commanded angular displacement is:

\[ \theta=n\theta_s \]

Where:

  • \(\theta\) is the angular displacement in degrees.
  • \(n\) is the number of full-step pulses.
  • \(\theta_s\) is the full-step angle in degrees.

For a motor with a 1.8° step angle, 50 successful steps produce:

\[ \theta=50(1.8^\circ) \]

\[ \boxed{\theta=90^\circ} \]

The shaft rotates through one-quarter of a revolution.

Rotational speed

The pulse frequency determines how quickly the motor is instructed to move.

If a motor receives \(f\) full-step pulses each second, its rotational speed is:

\[ \text{Revolutions per second}=\frac{f}{N} \]

Converting to revolutions per minute:

\[ \boxed{\text{rpm}=\frac{60f}{N}} \]

Where:

  • \(f\) is the pulse frequency, measured in pulses per second (pps).
  • \(N\) is the number of full steps per revolution.

For example, a 200-step motor receiving 200 pulses per second has a commanded rotational speed of:

\[ \text{rpm}=\frac{60(200)}{200} \]

\[ \boxed{60\text{ rpm}} \]

This assumes the rotor successfully follows every commanded step.

Worked example: calculating stepper motor rotation and speed

A stepper motor has a full-step angle of 1.8°. Its controller sends 450 full-step pulses at a constant frequency of 250 pulses per second.

Calculate:

  1. The total angular displacement.
  2. The time taken.
  3. The average rotational speed in rpm.

Step 1

\[ N=\frac{360^\circ}{1.8^\circ} \]

\[ N=200\text{ steps/revolution} \]

Step 2

\[ \theta=n\theta_s \]

\[ \theta=450(1.8^\circ) \]

\[ \theta=810^\circ \]

Convert this into revolutions:

\[ \frac{810}{360}=2.25\text{ revolutions} \]

Step 3

Time equals the number of pulses divided by the pulse frequency:

\[ t=\frac{n}{f} \]

\[ t=\frac{450}{250} \]

\[ t=1.8\text{ s} \]

Step 4

\[ \text{rpm}=\frac{2.25}{1.8}\times60 \]

\[ \boxed{75\text{ rpm}} \]

The motor completes 2.25 revolutions in 1.8 seconds, giving an average rotational speed of 75 rpm.

The important assumption is that the rotor successfully follows all 450 pulses. This is not guaranteed under every operating condition.

04Back emf and why stepper motors have speed limits

We have established that a stepper motor rotates by following a changing magnetic field.

But there’s a problem.

What happens when the controller changes the stator’s magnetic field faster than the rotor can respond?

To understand the answer, we need to return to electromagnetic induction.

Back emf also occurs in stepper motors

As the permanent-magnet rotor moves relative to the stator windings, the magnetic flux linking those windings changes.

This induces a voltage across the windings.

By Lenz’s law, the induced voltage opposes the voltage applied by the motor driver. This is another example of back emf.

The faster the rotor moves, the greater the rotational back emf, assuming the magnetic field and motor construction remain unchanged.

However, a stepper motor has an additional complication.

Its stator windings are coils with inductance. Inductance opposes changes in current, so the current cannot change instantaneously when the driver switches between phase states.

If the driver changes the winding currents too quickly, the current may not reach its intended value before the next change.

At low speeds:

  • Back emf is relatively small.
  • The driver has more time to establish the desired phase currents.
  • The stator produces the intended magnetic field.
  • The rotor can follow the changing field.

At high speeds:

  • Back emf becomes larger.
  • Inductance resists rapid changes in winding current.
  • The driver has less time to establish the required current.
  • The magnetic field may become weaker than intended.
  • The available motor torque decreases.

For a fixed magnetic arrangement, motor torque is approximately proportional to winding current over its normal operating range.

A reduction in current therefore means less available torque.

This is why a stepper motor cannot increase its speed indefinitely just by increasing the pulse frequency.

The driver matters, too. Many stepper drivers use regulated current and a supply voltage higher than the winding’s nominal voltage to establish current more quickly. This helps maintain torque at higher speeds, but it cannot remove every limitation.

The interaction between inductance and current growth is explained further in tutorgum’s guides to Self-Inductance: How Coils Oppose Changes in Current and RL Circuits: Understanding Current Growth and Decay.

What exactly is a missed step?

A missed step occurs when the rotor fails to follow the commanded magnetic field position.

The controller might send another pulse, expecting the rotor to advance by 1.8°, but the rotor may not complete that movement.

The controller still counts the pulse.

If the system has no encoder or other position feedback, it has no direct way of knowing that the rotor has fallen behind.

This is called open-loop control.

Several conditions can cause missed steps:

  1. Excessive load torque: The motor cannot generate enough torque to overcome the resistance of the attached load.
  2. Excessive pulse frequency: The magnetic field changes faster than the rotor can follow.
  3. Abrupt acceleration: The rotor and attached load have inertia, so they require torque to accelerate.
  4. Resonance: The motor’s natural oscillations become amplified at certain step frequencies.
  5. Insufficient winding current: Back emf and inductance prevent the driver from establishing enough current to generate the required torque.

A missed step does not necessarily mean the motor has permanently stalled. It may regain synchronism, but its actual position can remain different from the controller’s commanded position.

This is a fundamental limitation of open-loop positioning.

05Pull-in torque, pull-out torque, and acceleration

A particularly important feature of stepper motors is that the torque available when starting is not necessarily the same as the torque available when already running.

Two terms describe this difference.

Pull-in torque

Pull-in torque is the maximum load torque a motor can overcome when starting, stopping, or reversing at a particular pulse frequency without an acceleration ramp.

If the load exceeds the pull-in torque, the motor cannot start at that commanded frequency while remaining synchronised.

Pull-out torque

Pull-out torque is the maximum load torque the motor can overcome while already running in synchronism at a particular speed.

If the load exceeds the pull-out torque, the motor will lose synchronism.

The difference between these curves creates an important operating region.

A motor might be unable to start directly at a particular high speed, yet still be able to maintain that speed after gradually accelerating.

For example, suppose a motor has:

  • A pull-in torque of 0.08 N m at 800 pulses per second.
  • A pull-out torque of 0.20 N m at the same pulse frequency.

If the motor is stationary and the load requires 0.12 N m, it cannot start immediately at 800 pulses per second because the required torque exceeds its pull-in torque.

However, if the motor starts at a lower frequency and accelerates gradually, it may reach 800 pulses per second because the load torque is below its pull-out torque.

This is why stepper motor controllers often use an acceleration ramp.

Instead of immediately applying a high pulse frequency, the controller gradually increases the frequency, allowing the rotor and its attached load to accelerate.

The same principle applies when stopping or reversing. An abrupt change in pulse frequency can cause the rotor to lose synchronism.

The actual torque-speed curves depend on the motor, driver, supply voltage, winding current, and load. They must be considered together rather than treating the motor’s maximum speed as a universal value.

06Microstepping: making the angular increments smaller

So far, we have considered full-step operation.

But what if a motor needs to move in increments smaller than 1.8°?

One solution is called microstepping.

Instead of simply switching winding currents between fixed full-step states, the driver gradually changes the relative current in phases A and B.

This changes the direction of the resultant magnetic field in smaller increments.

The rotor follows these intermediate field positions, allowing the motor to make smaller commanded angular movements.

For example, consider a motor with 200 full steps per revolution.

If the driver divides every full step into 16 microsteps:

\[ N_\mu=200\times16 \]

\[ N_\mu=3200\text{ microsteps/revolution} \]

The nominal angular increment becomes:

\[ \theta_\mu=\frac{360^\circ}{3200} \]

\[ \boxed{\theta_\mu=0.1125^\circ} \]

Where:

  • \(N_\mu\) is the number of microsteps per revolution.
  • \(\theta_\mu\) is the nominal angular displacement per microstep.

This is a substantial improvement in commanded position resolution.

Microstepping also tends to reduce vibration and produce smoother movement.

However, there is an important limitation.

More microsteps do not automatically mean proportionally greater positional accuracy.

The rotor is not mechanically locked into every commanded microstep position. Its actual position depends on the magnetic forces, load, friction, rotor geometry, and accuracy of the driver current.

The surprising limitation of microstepping

At a full-step position, an energised motor can produce its specified holding torque.

Holding torque is the maximum static torque the energised motor can resist under its specified operating conditions.

At an intermediate microstep position, however, the torque required to pull the rotor away from that particular position can be considerably smaller.

This is called incremental torque.

In a simplified model with sinusoidal phase currents, the incremental torque at the first microstep away from a full-step position is approximately:

\[ T_{\mathrm{inc}}\approx T_{\mathrm{hold}}\sin\left(\frac{90^\circ}{m}\right) \]

Where:

  • \(T_{\mathrm{inc}}\) is the incremental torque at the microstep position, measured in N m.
  • \(T_{\mathrm{hold}}\) is the full-step holding torque, measured in N m.
  • \(m\) is the number of microsteps per full step.

For 16 microsteps per full step:

\[ \frac{T_{\mathrm{inc}}}{T_{\mathrm{hold}}} \approx\sin(5.625^\circ) \]

\[ \frac{T_{\mathrm{inc}}}{T_{\mathrm{hold}}} \approx0.098 \]

The incremental torque is therefore approximately 9.8% of the full-step holding torque at that particular position.

This is an idealised model. Real values depend on the motor’s magnetic construction, detent torque, friction, and driver accuracy.

The distinction is useful: a motor can have a substantial full-step holding torque while being relatively easy to displace from a particular microstep position.

Microstepping improves resolution and smoothness, but it doesn’t make the motor immune to external loads.

07Questions and solutions

The following questions move from basic motor calculations to the more subtle limitations of stepper motor positioning.

Question 1

A simple DC motor is connected to an 18 V supply. Its armature resistance is 3.0 Ω, and its steady-state current is 2.0 A.

(a) Calculate the back emf while the motor is running.

(b) Calculate the simplified starting current when the rotor is stationary.

Assume armature inductance and brush voltage drops are negligible.

Solution 1

The back emf is 12 V, and the simplified starting current is 6.0 A.

Part (a): Back emf

Apply the motor voltage equation:

\[ V=E_b+IR \]

Rearrange:

\[ E_b=V-IR \]

Substitute:

\[ E_b=18-(2.0)(3.0) \]

\[ \boxed{E_b=12\text{ V}} \]

The back emf opposes the supply voltage, reducing the effective voltage across the armature resistance.

Part (b): Starting current

At startup, the rotor is stationary, so:

\[ E_b=0 \]

The current is therefore:

\[ I=\frac{V}{R} \]

\[ I=\frac{18}{3.0} \]

\[ \boxed{I=6.0\text{ A}} \]

The starting current is three times the running current.

This happens because the stationary motor has no rotational back emf to oppose the supply. In a real motor, inductance affects how quickly the current rises, but the simplified steady-state model predicts the large starting current.

Question 2

A stepper motor has a full-step angle of 1.8°.

Starting from a reference position, its controller sends:

  • 360 clockwise full-step pulses at 240 pulses per second.
  • 90 anticlockwise full-step pulses at 180 pulses per second.

Assume the rotor successfully follows every pulse.

Calculate:

(a) The net angular displacement.

(b) The total time taken.

(c) The average signed angular velocity in rpm.

Solution 2

The motor completes a net clockwise displacement of 486° in 2.0 seconds, giving an average signed angular velocity of 40.5 rpm clockwise.

Part (a): Net angular displacement

First, calculate the angular displacement during the clockwise movement:

\[ \theta_1=360(1.8^\circ) \]

\[ \theta_1=648^\circ \]

Next, calculate the anticlockwise displacement:

\[ \theta_2=90(1.8^\circ) \]

\[ \theta_2=162^\circ \]

Since the two movements occur in opposite directions, subtract the smaller displacement:

\[ \theta_{\text{net}}=648^\circ-162^\circ \]

\[ \boxed{\theta_{\text{net}}=486^\circ} \]

The net displacement is clockwise.

Part (b): Total time

For the clockwise movement:

\[ t_1=\frac{360}{240} \]

\[ t_1=1.5\text{ s} \]

For the anticlockwise movement:

\[ t_2=\frac{90}{180} \]

\[ t_2=0.5\text{ s} \]

Therefore:

\[ t_{\text{total}}=1.5+0.5 \]

\[ \boxed{t_{\text{total}}=2.0\text{ s}} \]

Part (c): Average signed angular velocity

Convert the net displacement into revolutions:

\[ \frac{486}{360}=1.35\text{ revolutions} \]

Then:

\[ \text{rpm}=\frac{1.35}{2.0}\times60 \]

\[ \boxed{40.5\text{ rpm clockwise}} \]

The direction matters. Using the total distance travelled rather than the net displacement would calculate average rotational speed, not average signed angular velocity.

Question 3

A two-phase stepper motor operates with a current-regulated driver.

At a low pulse frequency of 200 pulses per second, each winding reaches its target current of 1.0 A before the next relevant phase transition.

At 900 pulses per second, the same driver and supply can only establish a winding current of 0.65 A before the next transition.

Assume motor torque is proportional to winding current over this operating range.

(a) Estimate the ratio of available torque at the higher speed to the torque at the lower speed.

(b) Explain why the winding current decreases at the higher speed. Include back emf and inductance in your explanation.

(c) Explain why increasing the pulse frequency does not guarantee that the actual shaft speed will increase proportionally.

Solution 3

The available torque at the higher speed is approximately 65% of the lower-speed torque. The reduced current results from the combined effects of back emf, winding inductance, and the shorter time available for current to change.

Part (a): Torque ratio

For the stated operating conditions:

\[ T\propto I \]

Therefore:

\[ \frac{T_{\text{high}}}{T_{\text{low}}} = \frac{I_{\text{high}}}{I_{\text{low}}} \]

Substitute:

\[ \frac{T_{\text{high}}}{T_{\text{low}}} = \frac{0.65}{1.0} \]

\[ \boxed{\frac{T_{\text{high}}}{T_{\text{low}}}=0.65} \]

The motor has approximately 65% of its previous available torque.

Part (b): Why does the current decrease?

Two effects contribute.

First, as the rotor moves faster, the rotational back emf increases. This induced voltage opposes the voltage applied by the driver, reducing the voltage available to establish the required winding current.

Second, the winding has inductance. It resists rapid changes in current, so the current cannot instantly reach its target when the driver changes the phase state.

At 900 pulses per second, the driver has less time to establish the required current.

The combined result is a lower phase current and therefore less available torque.

Part (c): Why doesn’t the shaft necessarily follow the pulse frequency?

The pulse frequency determines the speed of the commanded magnetic field.

However, the rotor must generate enough torque to accelerate and maintain its motion while following that field.

If the available torque becomes smaller than the torque required by the load and the motor’s acceleration, the rotor cannot maintain synchronism.

The driver can continue sending pulses even when the rotor fails to follow them.

Therefore, doubling the pulse frequency does not guarantee that the actual shaft speed will double.

The distinction is between commanded motion and actual mechanical motion.

Question 4

A manufacturer provides the following torque characteristics for a particular stepper motor and driver.

Pulse frequencyPull-in torquePull-out torque
100 pps0.28 N m0.36 N m
400 pps0.10 N m0.22 N m
800 pps0.04 N m0.12 N m

The motor is connected to a load that requires a constant resisting torque of 0.14 N m.

Assume the manufacturer’s pull-out curve remains above the load torque between 100 and 400 pps, but falls below it before 800 pps. Also assume a sufficiently gentle acceleration ramp, negligible additional acceleration torque for this comparison, and no significant resonance.

Determine:

(a) Whether the motor can start directly at 400 pps.

(b) Whether it can run at 400 pps after accelerating from a lower frequency.

(c) Whether it can maintain 800 pps under the stated load.

(d) Describe an appropriate starting strategy.

Solution 4

The motor cannot start directly at 400 pps, but it can run at 400 pps after gradual acceleration. It cannot maintain 800 pps under the specified load.

Part (a): Starting directly at 400 pps

The required load torque is:

\[ T_L=0.14\text{ N m} \]

At 400 pps, the pull-in torque is:

\[ T_{\text{pull-in}}=0.10\text{ N m} \]

Compare the values:

\[ 0.14>0.10 \]

The required load torque exceeds the available pull-in torque.

Therefore, the motor cannot start directly at 400 pps while maintaining synchronism.

Part (b): Running at 400 pps

At 400 pps, the pull-out torque is:

\[ T_{\text{pull-out}}=0.22\text{ N m} \]

Compare this with the load torque:

\[ 0.22>0.14 \]

The available running torque exceeds the required load torque.

Therefore, the motor can maintain 400 pps once it has accelerated to that speed.

This is the key difference between pull-in and pull-out torque.

Part (c): Running at 800 pps

At 800 pps:

\[ T_{\text{pull-out}}=0.12\text{ N m} \]

But the load requires:

\[ T_L=0.14\text{ N m} \]

Therefore:

\[ 0.12<0.14 \]

The motor cannot produce enough torque to maintain synchronism at 800 pps.

It will lose synchronism under the specified conditions.

Part (d): Appropriate starting strategy

The motor should begin at a lower pulse frequency, such as 100 pps, where its pull-in torque is greater than the load torque.

The controller should then gradually increase the pulse frequency towards 400 pps.

The motor can maintain 400 pps because its pull-out torque at that frequency is sufficient.

However, increasing the pulse frequency to 800 pps would exceed its running torque capability under the stated load.

The important lesson is that a motor’s ability to start at a particular speed and its ability to maintain that speed are different operating conditions.

Question 5

A hybrid stepper motor has:

  • 200 full steps per revolution.
  • A full-step holding torque of 0.40 N m.
  • A driver configured for 16 microsteps per full step.

The motor is stationary at the first microstep position beyond a full-step alignment.

For this motor, the incremental torque at that position is 9.8% of its full-step holding torque.

A constant external load applies a torque of 0.050 N m in the direction of the next microstep.

Assume the load is applied slowly, the stated incremental torque applies at this position, and friction and detent torque are negligible.

(a) Calculate the nominal angular displacement per microstep.

(b) Calculate the incremental torque at the stated position.

(c) Can the motor maintain its exact commanded microstep position under the external load?

(d) Explain why comparing the external load with the full-step holding torque gives a misleading prediction. State what the open-loop controller will report.

Solution 5

The nominal microstep angle is 0.1125°, and the incremental torque is 0.0392 N m. The motor cannot maintain its exact commanded microstep position under the stated load, even though the external torque is smaller than its full-step holding torque.

Part (a): Microstep angular displacement

The motor has a full-step angle of:

\[ \theta_s=\frac{360^\circ}{200} \]

\[ \theta_s=1.8^\circ \]

The driver divides each full step into 16 microsteps.

Therefore:

\[ \theta_\mu=\frac{1.8^\circ}{16} \]

\[ \boxed{\theta_\mu=0.1125^\circ} \]

This is the nominal angular increment commanded by the driver.

Part (b): Incremental torque

The incremental torque is 9.8% of the full-step holding torque.

Therefore:

\[ T_{\mathrm{inc}}=0.098T_{\mathrm{hold}} \]

Substitute:

\[ T_{\mathrm{inc}}=0.098(0.40) \]

\[ \boxed{T_{\mathrm{inc}}=0.0392\text{ N m}} \]

Part (c): Can the motor hold the commanded position?

No.

The external load torque is:

\[ T_L=0.050\text{ N m} \]

The available incremental torque is:

\[ T_{\mathrm{inc}}=0.0392\text{ N m} \]

Since:

\[ 0.050>0.0392 \]

the external torque exceeds the incremental torque available to resist displacement from that microstep position.

The rotor will therefore move away from its exact commanded position.

It may settle at a displaced equilibrium or move towards another stable position. The exact final angular position cannot be calculated from the supplied incremental torque alone; that would require the full torque-angle characteristic.

Part (d): Why is full-step holding torque misleading?

This is the important part of the question.

A tempting argument is:

\[ 0.050<0.40 \]

Therefore, the motor should hold its position.

But this compares the external load with the full-step holding torque rather than the incremental torque at the actual microstep position.

The two values are not interchangeable.

At an intermediate microstep position, the resultant magnetic field produces a smaller restoring torque against displacement. The rotor can therefore move under a load that is comfortably below the motor’s full-step holding torque.

There is another subtle point.

The motor is stationary, so its rotational back emf is essentially zero. The displacement in this question is not caused by high-speed back emf or insufficient time for current to build.

It is a limitation of the magnetic restoring torque at the selected microstep position.

Finally, the open-loop controller will continue to report the commanded microstep position. It counts the electrical commands, not the actual mechanical position of the rotor.

Without an encoder or another feedback mechanism, it cannot identify this positioning error.

This is why increasing the number of commanded microsteps does not guarantee an equivalent improvement in real-world positioning accuracy.

08Where stepper motors lead next

The key idea is that a stepper motor controls rotation by moving its stator’s magnetic field through a sequence of commanded positions. The rotor follows that field, producing predictable angular increments as long as the available electromagnetic torque is sufficient.

Back emf and winding inductance help explain why torque decreases at higher speeds. Rotor inertia, load torque, and resonance explain why a motor can lose synchronism even when its electrical drive appears to be working correctly.

The next useful concept is feedback control. An encoder measures the actual shaft position and allows a controller to compare it with the commanded position. This is how closed-loop stepper systems detect missed steps and correct positioning errors.

For a motor that is expected to move precisely, the distinction between the position it was told to reach and the position it actually reaches is just as important as the step angle itself.