Induction Heating: How Eddy Currents Produce Heat
Discover how induction heating uses changing magnetic fields to generate eddy currents and heat conducting materials. Explore the connection to real transformers, resistive heating, and the skin effect through worked examples and challenging HSC extension questions.
An induction cooktop can heat a compatible steel pan without a flame or a hot element touching it. The glass surface is not the main heat source. Instead, a changing magnetic field induces electrical currents inside the pan, and the pan’s electrical resistance converts those currents into heat.
This is called induction heating. The interesting part is that the same effect responsible for heating the pan is something engineers normally try to prevent inside a transformer. Eddy currents waste energy when they form in a transformer core, but become useful when they form in the metal being heated.
Induction heating goes beyond the required Year 12 Physics syllabus content. The assumed starting point is the Year 12 Electromagnetism material in the NSW Physics 11-12 Syllabus (2025), rather than an assessment requirement to understand induction heating. NESA schedules implementation of the new syllabus for Year 12 from Term 4, 2027, with the first HSC examination in 2028. You can study this extension without being in Year 12.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
01Start with the transformer model
Before looking at induction heating, recall how a transformer transfers electrical energy.
A basic transformer has two coils, called the primary and secondary windings. They share a magnetic field, usually guided through an iron core.
When an alternating current flows through the primary winding, it produces a changing magnetic field. This creates changing magnetic flux through the secondary winding, inducing an electromotive force (emf).
The relationship is described by Faraday’s law:
\[ \mathcal{E}=-N\frac{\Delta\Phi}{\Delta t} \]
Where:
- \(\mathcal{E}\) is the average induced emf, measured in volts (V).
- \(N\) is the number of turns in the coil.
- \(\Delta\Phi\) is the change in magnetic flux, measured in webers (Wb).
- \(\Delta t\) is the time over which the flux changes, measured in seconds (s).
- The negative sign represents Lenz’s law: the induced emf acts in a direction that opposes the change producing it.
Magnetic flux measures how much magnetic field passes through a surface. For a uniform magnetic field:
\[ \Phi=BA\cos\theta \]
Here, \(B\) is magnetic field strength in teslas (T), \(A\) is the area of the surface in square metres (m²), and \(\theta\) is the angle between the magnetic field and the surface’s normal.
The transformer works because the magnetic flux changes with time, allowing energy to be transferred between electrically separate circuits.
Ideal transformers versus real transformers
In the ideal transformer model, we assume that all the magnetic flux produced by the primary links the secondary. We also assume that no energy is lost through heating.
The ideal transformer equations are:
\[ \frac{V_p}{V_s}=\frac{N_p}{N_s} \]
and
\[ V_pI_p=V_sI_s \]
Where:
- \(V_p\) and \(V_s\) are the primary and secondary RMS voltages.
- \(I_p\) and \(I_s\) are the primary and secondary RMS currents.
- \(N_p\) and \(N_s\) are the numbers of turns in the primary and secondary windings.
The second equation states that input power equals output power in an ideal transformer.
Real transformers cannot achieve this perfect transfer. Three important effects explain why.
1. Incomplete flux linkage
Not all the magnetic flux produced by the primary winding passes through the secondary winding.
Some flux travels through the surrounding air and links only the primary. This is called leakage flux.
Consequently, less changing flux links the secondary than the ideal model assumes. The induced secondary emf is reduced, and leakage inductance can cause additional voltage drops when the transformer is operating under load.
This reduces the effectiveness of energy transfer.
An important distinction: leakage flux is not itself energy being converted into heat. It affects magnetic coupling and the voltage available to the load. Actual resistive and magnetic losses account for the dissipation of real electrical energy.
For a more detailed treatment of this effect, see Coupling Coefficients: Magnetic Flux Linkage in Real Transformers.
2. Eddy currents in the transformer core
The changing magnetic field can also induce circulating currents inside the conducting iron core.
These currents are called eddy currents. Because the core has electrical resistance, the currents produce heat.
That heat represents energy that is no longer available for useful output.
Engineers reduce this effect by constructing transformer cores from thin, insulated layers called laminations. These layers interrupt large circulating current paths and increase their electrical resistance.
The result is smaller eddy currents and less unwanted heating.
3. Resistive heating in the windings
The primary and secondary windings are made from conducting wire, which has electrical resistance.
Whenever current flows through a resistance, electrical energy is converted into thermal energy.
The rate of energy conversion is described by Joule’s law:
\[ P=I^2R \]
Where:
- \(P\) is power dissipated as heat, measured in watts (W).
- \(I\) is RMS current, measured in amperes (A).
- \(R\) is electrical resistance, measured in ohms (Ω).
For a transformer with two windings, the approximate copper losses are:
\[ P_{\text{copper}}=I_p^2R_p+I_s^2R_s \]
Here, \(R_p\) and \(R_s\) are the resistances of the primary and secondary windings.
The larger the current, the greater the resistive heating.
These effects explain why a real transformer delivers less useful power than an ideal transformer. Some energy is dissipated as heat in the windings and core, while incomplete flux linkage reduces the effectiveness of the transfer.
A real transformer can also experience hysteresis losses in its magnetic core, which arise from repeatedly reversing its magnetisation.
02How induction heating uses the same physics
Now consider a metal bar placed inside a coil carrying alternating current.
The coil creates an alternating magnetic field. This changing field passes through the conducting bar, inducing an emf inside the metal.
Here is the important change from an ordinary transformer: the workpiece itself acts as the secondary winding.
Instead of having a separate secondary coil made from wire, the metal provides paths through which the induced currents can flow.
An induction heater can therefore be modelled approximately as a transformer with:
- The induction coil acting as the primary winding.
- The metal workpiece acting as a single-turn secondary winding.
- The workpiece behaving like a short-circuited secondary because its induced currents circulate within the metal.
This is an equivalent-circuit model, not a claim that the workpiece is literally a single loop of wire. In reality, many distributed current paths form throughout the conducting material.
Engineering research uses this transformer model to analyse induction heaters, including the magnetic coupling and resistance of the workpiece. See the University of Canterbury’s research on induction and transduction heaters.
Where do the eddy currents come from?
Imagine looking at a cross-section of the metal bar.
As the magnetic flux through the bar changes, Faraday’s law predicts an induced emf around closed paths within the conducting material.
Because the metal is electrically conducting, charges move in response to this induced emf. The result is a collection of circulating currents.
These currents are called eddy currents.
They are not confined to a single wire or circuit. They circulate through the metal itself.
Lenz’s law also applies here.
The induced currents produce their own magnetic fields, which oppose the change in magnetic flux that produced them.
This does not mean the induced field simply cancels the original field. Instead, it opposes the change, with the current reversing as the applied magnetic field alternates.
The power supply must continually provide energy to maintain the changing magnetic field against this electromagnetic response.
That energy is transferred into the workpiece.
Why does the metal heat up?
The induced eddy currents encounter electrical resistance as they circulate through the metal.
The moving charges transfer energy to the material through interactions with its atomic structure. This increases the internal energy of the workpiece, raising its temperature.
The heating is described by the same Joule heating equation used for transformer windings:
\[ P_{\text{workpiece}}=I_{\text{rms}}^2R \]
The difference is where the heating occurs and whether it is useful.
| Location | Eddy-current heating | Purpose |
|---|---|---|
| Transformer core | Unwanted | Reduce it to improve efficiency |
| Induction-heated workpiece | Desired | Convert electrical energy into useful heat |
| Nearby conducting structures | Usually unwanted | Minimise unnecessary heating |
Notice that eddy currents are not inherently good or bad. Their usefulness depends on where they form.
In a transformer core, they reduce efficiency. In an induction-heated workpiece, they are the mechanism that makes the heater work.
A useful prediction: what happens with DC?
Suppose the alternating current in the induction coil is replaced with a steady direct current.
Would the metal continue heating at the same rate?
No. When the DC current is first switched on, the magnetic field changes as it rises to its steady value. This initial change can induce currents in the workpiece.
However, once the current becomes constant, the magnetic field also becomes constant.
The magnetic flux is no longer changing, so the induced emf falls to zero. Sustained eddy-current heating therefore stops.
This is why induction heating requires a changing magnetic field rather than simply a strong, constant magnetic field.
Worked example: calculating heating power in a metal rod
A metal rod is placed inside an induction coil. For a simplified model, represent one effective eddy-current path in the rod as a single closed circuit.
The induced RMS emf is 3.0 V, and the resistance of the current path is 0.15 Ω.
Calculate:
- The induced RMS current.
- The average power converted into heat.
- The energy deposited in the rod over 20 seconds.
Assume the effective circuit is purely resistive and ignore heat loss to the surroundings.
Step 1
Using Ohm’s law:
\[ I=\frac{\mathcal{E}}{R} \]
Substituting:
\[ I=\frac{3.0}{0.15} \]
\[ \boxed{I=20\text{ A}} \]
Step 2
Using Joule’s law:
\[ P=I^2R \]
Substituting:
\[ P=20^2\times0.15 \]
\[ \boxed{P=60\text{ W}} \]
Step 3
Using \(E=Pt\), where \(E\) is energy in joules and \(t\) is time in seconds:
\[ E=60\times20 \]
\[ \boxed{E=1200\text{ J}} \]
The effective eddy-current path dissipates 60 W as heat, transferring 1200 J of energy over 20 seconds.
This is energy transferred into the metal without requiring an electrical connection between the induction coil and the rod.
The single-loop model is useful for understanding the calculation, but a real workpiece contains many interacting current paths.
03Why frequency changes the heating process
So far, we have established that changing magnetic flux induces an emf, and that the resulting currents produce heat.
But induction heaters also use frequency to control how deeply the metal is heated.
Consider a magnetic field that varies sinusoidally:
\[ B(t)=B_{\max}\sin(2\pi ft) \]
Here:
- \(B_{\max}\) is the maximum magnetic field strength.
- \(f\) is the frequency of the alternating field, measured in hertz (Hz).
- \(t\) is time in seconds.
For a single effective loop with a fixed area perpendicular to the field, the maximum induced emf is:
\[ \mathcal{E}_{\max}=2\pi fB_{\max}A \]
This tells us something important.
If the maximum magnetic field strength and loop area remain constant, increasing the frequency increases the maximum induced emf.
A faster-changing magnetic field produces a greater rate of change of magnetic flux.
However, there is another effect that becomes increasingly important at higher frequencies.
The skin effect
In an alternating magnetic field, induced currents do not distribute evenly throughout a solid conductor.
They tend to concentrate near the surface.
This phenomenon is called the skin effect.
At relatively low frequencies, eddy currents can penetrate further into the metal. At higher frequencies, they become increasingly concentrated near the surface.
The characteristic penetration distance is called the skin depth, represented by \(\delta\).
For a uniform conducting material under sinusoidal steady-state conditions, an approximate expression is:
\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]
Where:
- \(\delta\) is skin depth, measured in metres (m).
- \(\rho\) is electrical resistivity, measured in ohm metres (Ω m).
- \(f\) is the frequency of the alternating magnetic field, measured in hertz (Hz).
- \(\mu\) is the absolute magnetic permeability of the material, measured in henries per metre (H/m).
The equation gives three useful relationships.
- Increasing frequency decreases skin depth.
- Increasing magnetic permeability decreases skin depth.
- Increasing electrical resistivity increases skin depth.
Skin depth is the distance from the surface at which the current density has fallen to approximately 37% of its surface value.
It does not mean that all heating stops beyond that depth. It describes how the electromagnetic current is distributed, not the final temperature distribution. Heat can subsequently spread further into the workpiece through thermal conduction.
This gives induction heating an important industrial advantage.
For example, a steel gear may need a very hard outer surface while retaining a tougher interior. A high-frequency induction heater can concentrate the heating near the surface, allowing the outer region to undergo heat treatment without initially heating the entire gear to the same temperature.
Lower frequencies can be more suitable when deeper heating is required.
The IEEE overview of induction heating discusses this relationship between frequency, penetration depth, and industrial applications.
There is one limitation to the simple skin-depth equation: it assumes that the material properties remain constant. In real steel, resistivity and magnetic permeability can change significantly as temperature rises. Geometry also affects the distribution of current.
Consequently, the equation is useful for understanding trends, but it does not provide an exact heating-depth prediction for every workpiece.
Worked example: calculating induced emf and heating power
An aluminium billet is placed inside an induction coil.
For a simplified model, consider one effective eddy-current loop within the billet.
The magnetic field through the loop varies sinusoidally with a maximum strength of 0.20 T at a frequency of 1.5 kHz.
The loop has an area of 3.0 cm² and an effective resistance of 0.050 Ω.
Calculate:
- The maximum magnetic flux through the loop.
- The RMS induced emf.
- The RMS induced current.
- The average heating power.
Assume the field is uniform and perpendicular to the loop, and that the resistance remains constant.
Step 1
\[ A=3.0\text{ cm}^2 =3.0\times10^{-4}\text{ m}^2 \]
Step 2
Since the magnetic field is perpendicular to the loop:
\[ \Phi_{\max}=B_{\max}A \]
Substituting:
\[ \Phi_{\max} =0.20\times3.0\times10^{-4} \]
\[ \boxed{\Phi_{\max}=6.0\times10^{-5}\text{ Wb}} \]
Step 3
Using Faraday’s law for a sinusoidally changing flux:
\[ \mathcal{E}_{\max}=2\pi f\Phi_{\max} \]
Substituting:
\[ \mathcal{E}_{\max} =2\pi(1500)(6.0\times10^{-5}) \]
\[ \mathcal{E}_{\max}=0.565\text{ V} \]
The RMS emf is:
\[ \mathcal{E}_{\mathrm{rms}} =\frac{\mathcal{E}_{\max}}{\sqrt{2}} \]
\[ \boxed{\mathcal{E}_{\mathrm{rms}}=0.400\text{ V}} \]
Step 4
\[ I_{\mathrm{rms}} =\frac{\mathcal{E}_{\mathrm{rms}}}{R} \]
\[ I_{\mathrm{rms}} =\frac{0.400}{0.050} \]
\[ \boxed{I_{\mathrm{rms}}=8.0\text{ A}} \]
Step 5
\[ P=I_{\mathrm{rms}}^2R \]
\[ P=8.0^2\times0.050 \]
\[ \boxed{P=3.2\text{ W}} \]
The effective current path dissipates 3.2 W as heat.
Notice that the frequency appears directly in the induced emf equation. Increasing frequency while keeping the maximum magnetic field and loop area constant increases the rate of flux change.
However, this calculation assumes a fixed resistance and a single effective current loop. A real billet has distributed currents, and its effective resistance changes with frequency because of the skin effect.
It would therefore be incorrect to use this simple calculation to predict the exact power output of an industrial induction heater.
04What determines the useful heating power?
The workpiece does not automatically receive all the electrical power supplied to the induction coil.
Several factors determine how much energy is transferred into the target material.
Magnetic coupling
The induction coil must produce magnetic flux that links effectively with the workpiece.
If the workpiece is poorly positioned or the magnetic coupling is weak, less energy is transferred into it.
This is related to the incomplete flux linkage discussed earlier for real transformers.
Electrical resistance
The workpiece must be electrically conducting so that induced currents can circulate.
Those currents dissipate energy through resistance.
However, be careful with the statement that a higher resistance always produces more heating.
The equation \(P=I^2R\) only tells us what happens if current is held constant. If induced emf is held constant instead, increasing resistance reduces current, and the power can decrease.
The actual result depends on how the induction heater and workpiece interact.
Frequency and skin effect
Frequency affects both the induced emf and the depth of current penetration.
A higher frequency can concentrate heating near the surface, while a lower frequency can allow deeper penetration.
The best frequency depends on the dimensions, material, and desired heating depth.
Energy lost elsewhere
The induction coil also has electrical resistance. Its current produces unwanted resistive heating.
Power electronics, surrounding conductive structures, and imperfect magnetic coupling can introduce further losses.
In ferromagnetic workpieces, magnetic hysteresis can also contribute to heating. This occurs because the material’s magnetisation changes repeatedly as the magnetic field alternates.
Therefore, induction heating involves several interacting processes, not simply a magnetic field creating a current.
The central idea is that induction heating deliberately transfers electrical energy into a conductor through electromagnetic induction, then converts that energy into thermal energy through resistive heating.
05Questions and solutions
The following questions move from straightforward calculations to problems that combine transformer efficiency, Faraday’s law, skin effect, and thermal feedback.
Question 1
A steel rod is positioned inside an induction coil.
In a simplified model, one effective eddy-current path within the rod has an induced RMS emf of 2.4 V and an electrical resistance of 0.12 Ω.
Calculate:
a) The RMS current in the path.
b) The average power converted into heat.
Solution 1
The induced current is 20 A RMS, and the average heating power is 48 W.
The induced emf drives current through the resistance of the metal. The electrical energy is converted into heat through Joule heating.
Part a: Calculate the current.
Using Ohm’s law:
\[ I=\frac{\mathcal{E}}{R} \]
Substituting:
\[ I=\frac{2.4}{0.12} \]
\[ \boxed{I=20\text{ A}} \]
Part b: Calculate the heating power.
Using Joule’s law:
\[ P=I^2R \]
Substituting:
\[ P=20^2\times0.12 \]
\[ \boxed{P=48\text{ W}} \]
The current transfers energy into the steel rod at an average rate of 48 joules per second.
Remember that the current is induced by the changing magnetic field. There is no need for the rod to be physically connected to the induction coil.
Question 2
An aluminium billet is placed inside an induction coil.
Consider one effective eddy-current loop with an area of 4.0 cm². The magnetic field perpendicular to the loop varies according to:
\[ B(t)=0.25\sin(2\pi ft) \]
The frequency is 2.0 kHz, and the effective electrical resistance of the loop is 0.080 Ω.
Assume that the field is uniform and that the resistance remains constant.
a) Calculate the maximum magnetic flux through the loop.
b) Calculate the RMS induced emf.
c) Calculate the RMS current and average heating power.
d) If the frequency doubles while the maximum magnetic field strength and resistance remain constant, determine the predicted change in heating power according to this simplified model.
Solution 2
The maximum flux is \(1.0\times10^{-4}\text{ Wb}\), the RMS induced emf is approximately 0.89 V, and the heating power is approximately 9.9 W. Doubling the frequency predicts four times the heating power under the stated fixed-resistance model.
Part a: Calculate the maximum flux.
First, convert the area:
\[ A=4.0\times10^{-4}\text{ m}^2 \]
Using:
\[ \Phi_{\max}=B_{\max}A \]
Substituting:
\[ \Phi_{\max} =0.25\times4.0\times10^{-4} \]
\[ \boxed{\Phi_{\max}=1.0\times10^{-4}\text{ Wb}} \]
Part b: Calculate the RMS induced emf.
The frequency is:
\[ f=2.0\times10^3\text{ Hz} \]
The maximum induced emf for a single-turn loop is:
\[ \mathcal{E}_{\max}=2\pi f\Phi_{\max} \]
Substituting:
\[ \mathcal{E}_{\max} =2\pi(2000)(1.0\times10^{-4}) \]
\[ \mathcal{E}_{\max}=1.257\text{ V} \]
Convert to RMS:
\[ \mathcal{E}_{\mathrm{rms}} =\frac{1.257}{\sqrt{2}} \]
\[ \boxed{\mathcal{E}_{\mathrm{rms}}=0.89\text{ V}} \]
Part c: Calculate current and heating power.
Using Ohm’s law:
\[ I_{\mathrm{rms}} =\frac{0.89}{0.080} \]
\[ \boxed{I_{\mathrm{rms}}=11.1\text{ A}} \]
Now calculate power:
\[ P=I_{\mathrm{rms}}^2R \]
\[ P=11.1^2\times0.080 \]
\[ \boxed{P\approx9.9\text{ W}} \]
The effective eddy-current loop converts approximately 9.9 W into heat.
Part d: Determine the effect of doubling frequency.
The maximum induced emf is proportional to frequency when magnetic field amplitude and loop area are fixed:
\[ \mathcal{E}\propto f \]
Therefore, doubling frequency doubles the induced emf.
With resistance fixed:
\[ I=\frac{\mathcal{E}}{R} \]
The induced current also doubles.
Since:
\[ P=I^2R \]
the heating power becomes four times larger.
\[ P_{\mathrm{new}}=4(9.9) \]
\[ \boxed{P_{\mathrm{new}}\approx39.6\text{ W}} \]
This result applies to the simplified single-loop model. It does not guarantee that a real induction heater will produce four times as much power when its frequency doubles. The skin effect changes the current distribution and effective resistance, and the magnetic field may also change.
Question 3
A practical transformer supplies an induction heating system.
The following measurements are recorded:
| Quantity | Power |
|---|---|
| Electrical input power | 1000 W |
| Useful heating power delivered to the workpiece | 820 W |
| Resistive heating in transformer windings | 50 W |
| Eddy-current heating in transformer core | 20 W |
An engineer claims that the remaining 110 W must be dissipated by leakage flux.
Evaluate this claim.
In your answer:
a) Calculate the overall efficiency of converting electrical input power into useful workpiece heating.
b) Calculate the total power that has not been delivered as useful workpiece heating.
c) Explain why the remaining unaccounted power cannot automatically be attributed to leakage flux.
Solution 3
The overall efficiency is 82%, and 180 W of input power has not been delivered as useful workpiece heating. The engineer’s explanation is not justified because leakage flux is not itself a mechanism that dissipates real power as heat.
Part a: Calculate the efficiency.
Efficiency is the ratio of useful output power to input power:
\[ \eta=\frac{P_{\mathrm{useful}}}{P_{\mathrm{input}}} \]
Substituting:
\[ \eta=\frac{820}{1000} \]
\[ \eta=0.82 \]
Therefore:
\[ \boxed{\eta=82\%} \]
Only 82% of the electrical input power is measured as useful heating in the workpiece.
Part b: Calculate the difference between input and useful output.
\[ P_{\mathrm{difference}} =P_{\mathrm{input}}-P_{\mathrm{useful}} \]
\[ P_{\mathrm{difference}}=1000-820 \]
\[ \boxed{P_{\mathrm{difference}}=180\text{ W}} \]
Of this amount, 50 W is identified as winding heating and 20 W as core eddy-current heating.
The remaining unaccounted power is:
\[ P_{\mathrm{unaccounted}}=180-50-20 \]
\[ \boxed{P_{\mathrm{unaccounted}}=110\text{ W}} \]
Part c: Evaluate the leakage-flux explanation.
The claim is incorrect.
Leakage flux is magnetic flux that links one winding without linking the other. It reduces magnetic coupling and produces leakage reactance, which can cause voltage drops under load.
However, leakage flux is not automatically converted into heat.
The 110 W must be accounted for by other real-power losses, such as additional magnetic losses, losses in the power electronics, heating of surrounding structures, or measurement uncertainty.
The supplied measurements do not identify which explanation accounts for the missing power.
The important distinction is that incomplete flux linkage reduces the effectiveness of energy transfer, whereas resistive heating and eddy currents in the core dissipate real electrical energy.
Question 4
Two identical solid steel rods are placed inside separate induction coils.
Both systems produce the same maximum magnetic field strength at the workpiece, and the rods have identical dimensions and material properties.
However, the first system operates at 1.0 kHz, while the second operates at 9.0 kHz.
Assume that the magnetic permeability and electrical resistivity remain constant.
a) Calculate the ratio of the skin depths in the two rods.
b) Identify which system produces more concentrated surface heating.
c) A student argues that the 9.0 kHz system must deposit exactly 81 times as much total heating power as the 1.0 kHz system because the frequency is nine times greater. Explain why this conclusion is not justified.
Solution 4
The 9.0 kHz system has one-third the skin depth of the 1.0 kHz system. It produces more concentrated surface heating, but it cannot be concluded that its total heating power is exactly 81 times greater.
Part a: Calculate the ratio of skin depths.
The skin-depth equation is:
\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]
Since both rods have identical material properties:
\[ \delta\propto\frac{1}{\sqrt f} \]
Therefore:
\[ \frac{\delta_2}{\delta_1} =\sqrt{\frac{f_1}{f_2}} \]
Substituting:
\[ \frac{\delta_2}{\delta_1} =\sqrt{\frac{1.0}{9.0}} \]
\[ \boxed{\frac{\delta_2}{\delta_1}=\frac13} \]
The higher-frequency system has one-third the characteristic penetration depth.
Part b: Identify the heating distribution.
The 9.0 kHz system produces more concentrated surface heating.
Its higher frequency causes the induced currents to concentrate closer to the surface of the steel rod.
The lower-frequency system allows the induced currents to penetrate further into the material.
Part c: Evaluate the 81-times-power claim.
The student’s argument uses a valid result from the simplified single-loop model, but applies it too broadly.
If the magnetic field amplitude, loop area, and resistance of a single effective loop remain constant, increasing frequency by a factor of nine increases induced emf by a factor of nine.
The current would also increase by a factor of nine, giving:
\[ P=I^2R \]
\[ P_{\mathrm{new}}=9^2P_{\mathrm{old}} \]
\[ P_{\mathrm{new}}=81P_{\mathrm{old}} \]
However, a solid metal rod does not behave like one isolated loop with an unchanged resistance.
As frequency increases, the skin effect changes the distribution of current within the workpiece. The effective resistance, magnetic coupling, and current paths can also change.
Furthermore, the induction system’s power supply may not maintain the same magnetic field amplitude under different operating conditions.
Therefore, the 81-times prediction is valid only under the artificial fixed-loop assumptions. It cannot be used to determine the total heating power of the real steel rods without additional information.
Question 5
An aluminium billet is being heated inside an induction coil.
To investigate how heating changes as the billet gets hotter, an engineer uses the following simplified model:
- The billet has a mass of 0.50 kg.
- Its specific heat capacity is 900 J kg⁻¹ K⁻¹.
- The effective induced RMS emf remains constant at 4.0 V.
- The workpiece is represented by one purely resistive eddy-current loop.
- At 20°C, the loop resistance is 0.20 Ω.
- As the billet heats, its resistance follows the approximate model:
\[ R(T)=0.20[1+0.004(T-20)] \]
Here, \(R(T)\) is the loop resistance in ohms and \(T\) is the billet temperature in degrees Celsius.
Assume this resistance model remains valid throughout the temperature range considered.
The billet also loses heat to its surroundings at a constant rate of 40 W.
The induction system maintains a constant induced RMS emf by keeping the magnetic field amplitude and frequency fixed. Assume that magnetic coupling and permeability remain unchanged.
Ignore skin-effect changes and assume the electrical heating is distributed uniformly throughout the billet.
a) At 20°C, calculate the induced current and electrical heating power.
b) Calculate the initial rate of temperature increase.
c) Determine the temperature at which the billet reaches thermal equilibrium.
d) Explain whether this equilibrium is stable.
e) A student argues that increasing resistance must increase heating because \(P=I^2R\). Explain precisely why this prediction is wrong under the conditions given.
Solution 5
The initial heating power is 80 W, the initial temperature rise is approximately 0.089°C per second, and the billet reaches a stable thermal equilibrium at 270°C.
The key is that the induced emf remains constant, not the current in the workpiece. As the resistance increases, the induced current decreases, reducing the electrical heating power.
Part a: Calculate the initial current and heating power.
At 20°C, the resistance is:
\[ R=0.20\ \Omega \]
Using Ohm’s law:
\[ I=\frac{\mathcal{E}}{R} \]
\[ I=\frac{4.0}{0.20} \]
\[ \boxed{I=20\text{ A}} \]
The electrical heating power is:
\[ P=I^2R \]
\[ P=20^2\times0.20 \]
\[ \boxed{P=80\text{ W}} \]
The billet initially receives 80 W of electrical heating.
Part b: Calculate the initial rate of temperature increase.
Not all 80 W contributes to increasing the billet’s temperature.
The billet loses 40 W to its surroundings.
Therefore, the net heating power is:
\[ P_{\mathrm{net}}=80-40 \]
\[ P_{\mathrm{net}}=40\text{ W} \]
The relationship between thermal energy and temperature change is:
\[ Q=mc\Delta T \]
Where:
- \(Q\) is thermal energy in joules.
- \(m\) is mass in kilograms.
- \(c\) is specific heat capacity in J kg⁻¹ K⁻¹.
- \(\Delta T\) is temperature change in kelvins.
The rate of temperature increase is:
\[ \frac{\Delta T}{\Delta t} =\frac{P_{\mathrm{net}}}{mc} \]
Substituting:
\[ \frac{\Delta T}{\Delta t} =\frac{40}{0.50\times900} \]
\[ \boxed{\frac{\Delta T}{\Delta t} =0.089\text{ K/s}} \]
A temperature increase of one kelvin is equal in magnitude to an increase of one degree Celsius.
The billet initially heats at approximately 0.089°C per second.
Part c: Determine the equilibrium temperature.
Thermal equilibrium occurs when the electrical heating power equals the rate of heat loss.
Therefore:
\[ P_{\mathrm{electrical}}=40\text{ W} \]
Because the induced RMS emf remains constant and the loop is purely resistive, we can write:
\[ P=\frac{\mathcal{E}_{\mathrm{rms}}^2}{R} \]
Substituting:
\[ 40=\frac{4.0^2}{R} \]
Rearranging:
\[ R=\frac{16}{40} \]
\[ \boxed{R=0.40\ \Omega} \]
Now use the temperature-dependent resistance equation:
\[ R(T)=0.20[1+0.004(T-20)] \]
Substituting the equilibrium resistance:
\[ 0.40=0.20[1+0.004(T-20)] \]
Divide both sides by 0.20:
\[ 2=1+0.004(T-20) \]
Rearranging:
\[ 1=0.004(T-20) \]
\[ T-20=250 \]
\[ \boxed{T=270^\circ\text{C}} \]
The billet reaches thermal equilibrium at 270°C under the assumptions of the model.
Part d: Determine whether the equilibrium is stable.
The equilibrium is stable.
Consider what happens if the temperature rises slightly above 270°C.
The resistance increases because the model specifies that resistance rises with temperature.
Since the induced emf remains constant:
\[ P_{\mathrm{electrical}} =\frac{\mathcal{E}_{\mathrm{rms}}^2}{R} \]
The electrical heating power decreases.
It therefore becomes smaller than the constant 40 W heat loss. The billet loses energy faster than it gains energy, so its temperature falls towards equilibrium.
Now consider a temperature slightly below 270°C.
The resistance decreases, so the electrical heating power increases.
The heating power becomes greater than the 40 W heat loss, causing the billet to warm towards equilibrium.
In both cases, the system tends to return to 270°C.
Part e: Explain the resistance misconception.
The student’s conclusion is incorrect because it assumes that the current remains constant while the resistance increases.
The equation:
\[ P=I^2R \]
is correct, but the current is not independent of the resistance in this system.
The induced emf is held constant, so:
\[ I=\frac{\mathcal{E}}{R} \]
Substituting this into the power equation gives:
\[ P=\left(\frac{\mathcal{E}}{R}\right)^2R \]
Therefore:
\[ \boxed{P=\frac{\mathcal{E}^2}{R}} \]
This shows that, at constant induced emf, increasing resistance decreases heating power.
If the current were held constant instead, increasing resistance would increase heating power. But that is not the situation described in this question.
This is the important conceptual distinction: Joule’s law does not tell you how power changes when resistance changes until you know what happens to the current or voltage.
The model also illustrates how electrical and thermal behaviour interact. A change in temperature changes resistance, which changes induced current and heating power, which then affects the temperature again.
Real induction heaters require more detailed models because magnetic coupling, frequency, permeability, and current distribution can also change as the workpiece heats.
06Where to take this next
Induction heating brings together three ideas that are often studied separately:
- Faraday’s law explains how changing magnetic flux induces an emf.
- Lenz’s law explains the direction of the induced currents and connects the process to conservation of energy.
- Joule’s law explains how those currents convert electrical energy into thermal energy.
The next useful step is understanding how the induction coil behaves as an AC circuit. Its inductive reactance, resistance, phase difference, and magnetic coupling determine how much real power the supply delivers to the workpiece.
That is where induction heating connects naturally to AC Impedance: Understanding Reactance and Phase Differences.