Why Ion Concentration Changes a Galvanic Cell’s Voltage

Discover why changing ion concentrations alters a galvanic cell's measured voltage, even when both electrodes are identical. Explore copper concentration cells, electrode reactions, ion movement, and worked voltage calculations.

Two copper strips sit in separate beakers of copper sulfate solution, connected to a voltmeter. Both electrodes are made of the same metal, so should the voltage be zero?

Not necessarily. If one solution contains ten times as many copper(II) ions per litre as the other, the cell can produce a potential difference of approximately \(0.030\ \mathrm{V}\) at \(25^\circ\mathrm{C}\).

Concentration changes can alter a galvanic cell’s measured voltage because they change the relative tendency for reduction and oxidation at its electrodes. A cell’s standard potential, \(E^\circ_{\mathrm{cell}}\), is a reference value. Its actual potential depends on the chemical conditions, including ion concentrations.

The interesting part is that we can demonstrate this using two identical copper electrodes. No difference in metal reactivity is needed.

Two separate beakers contain 0.0100 mol L⁻¹ and 0.100 mol L⁻¹ blue copper sulfate solutions, each with an immersed copper strip. A potassium nitrate salt bridge connects the solutions, while black and red leads connect the electrodes to a digital voltmeter with a blank display.
Identical copper strips sit in different copper sulfate concentrations, linked by a potassium nitrate bridge and a blank voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

01How can two identical electrodes produce a voltage?

Imagine investigating whether copper(II)-ion concentration affects a galvanic cell’s voltage.

You want to change the concentration without introducing a different metal. Otherwise, you wouldn’t know whether a change in voltage came from the metal or the solution.

Building the first experimental arrangement

Prepare two separate beakers:

  • Left beaker: 100 mL of \(0.0100\ \mathrm{mol\,L^{-1}}\) copper(II) sulfate solution.
  • Right beaker: 100 mL of \(0.100\ \mathrm{mol\,L^{-1}}\) copper(II) sulfate solution.

Place a clean copper electrode in each beaker. Both electrodes should have comparable exposed surfaces.

Connect the left electrode to the black terminal of a high-resistance voltmeter and the right electrode to its red terminal.

There’s an important missing connection.

The wire connects the two metals electrically, but the solutions are still separated. For a galvanic reaction to continue, charge must also be able to move through an ionic pathway.

Why the first design is incomplete

Suppose you try to run the cell without a salt bridge.

At one electrode, oxidation produces positively charged copper(II) ions. At the other, reduction removes copper(II) ions from the solution.

Without ionic charge compensation, even a small amount of electron transfer produces an opposing charge imbalance. The intended galvanic reaction cannot continue steadily.

An unstable or transient electrical response would not establish that the cell can supply a sustained current.

The design needs an ionic connection.

Two copper electrodes in separate CuSO₄ beakers are connected by an external wire in both panels. The left setup has no ionic connection. The right setup includes a U-shaped KNO₃ salt bridge with both ends immersed in the solutions.
The external wire provides the electronic path, while the immersed KNO₃ salt bridge provides the ionic connection between the separate CuSO₄ solutions.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Revising the apparatus

Add a salt bridge containing potassium nitrate, \(\ce{KNO3}\), between the beakers.

The bridge provides a pathway for mobile ions without requiring the copper sulfate solutions to be poured together.

Now the cell has two distinct pathways:

  • Electrons can travel through the external circuit when the cell supplies current.
  • Ions can move through the solutions and salt bridge to maintain approximate electrical neutrality.

Keep the temperature at \(25^\circ\mathrm{C}\), and use a high-resistance voltmeter so that measuring the voltage draws very little current.

This is important because we want to measure the cell’s potential before significant copper deposition or dissolution changes the solution concentrations.

Predicting the electrode reactions

Which copper electrode should release electrons?

It might seem impossible to choose because both electrodes are copper. But their surrounding solutions are different.

The dilute half-cell becomes the anode, where copper metal is oxidised:

\[ \ce{Cu(s) -> Cu^2+(aq) + 2e-} \]

The concentrated half-cell becomes the cathode, where copper(II) ions are reduced:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

The more concentrated solution provides a greater tendency for copper(II) ions to undergo reduction relative to the dilute solution.

When the cell supplies current, electrons travel through the external circuit from the dilute half-cell towards the concentrated half-cell.

Copper dissolves at the dilute electrode, while copper deposits onto the concentrated electrode.

Detailed copper concentration cell showing dilute CuSO₄ at the negative copper anode, concentrated CuSO₄ at the positive copper cathode, copper dissolution and deposition, electron flow through an external load, and oppositely migrating NO₃⁻ and K⁺ ions in a KNO₃ salt bridge.
The concentration difference drives copper oxidation at the dilute anode and reduction at the concentrated cathode, while electrons and salt-bridge ions complete the circuit.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Following the ions through the salt bridge

The electrode reactions alter the charge balance in opposite ways.

At the anode, copper atoms enter the solution as \(\mathrm{Cu}^{2+}\). This produces additional positive charge.

Negative nitrate ions, \(\ce{NO3-}\), migrate towards this half-cell to compensate.

At the cathode, copper(II) ions leave the solution as copper metal deposits. Positive potassium ions, \(\mathrm{K}^{+}\), migrate towards this half-cell to compensate.

The movement can be summarised as follows.

Part of the cellWhat happens during discharge?
Dilute copper electrodeCopper atoms lose electrons and dissolve
External circuitElectrons flow from dilute to concentrated electrode
Salt bridge towards dilute half-cell\(\ce{NO3-}\) ions migrate towards the anode
Salt bridge towards concentrated half-cell\(\mathrm{K}^{+}\) ions migrate towards the cathode
Concentrated copper electrodeCopper(II) ions gain electrons and deposit

These directions describe a cell supplying current. During a high-resistance voltage measurement, the current and associated ion movement are very small.

The salt bridge maintains the electrical circuit. It does not provide the electrons.

02Why the standard cell potential is zero but the actual voltage isn’t

A standard reduction potential describes a half-reaction under standard-state conditions.

For an aqueous electrochemical system, HSC calculations usually represent standard conditions using concentrations of \(1.0\ \mathrm{mol\,L^{-1}}\), pure solids, and tabulated potentials at \(25^\circ\mathrm{C}\). Gas standards use a pressure of 100 kPa.

More precisely, standard electrode potentials use chemical activities rather than concentrations alone. Concentration is a useful approximation for the models used here.

For the copper half-reaction:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

The standard reduction potential at \(25^\circ\mathrm{C}\) is approximately:

\[ E^\circ=+0.34\ \mathrm{V} \]

This is measured relative to the standard hydrogen electrode, which is assigned a potential of \(0.00\ \mathrm{V}\).

Both half-cells in our experiment use the same copper reduction reaction.

Therefore:

\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{cathode}} -E^\circ_{\mathrm{anode}}\\ &=+0.34-(+0.34)\\ &=0.00\ \mathrm{V} \end{aligned} \]

The standard cell potential is zero.

But the experimental solutions are not at identical concentrations.

The copper electrodes have different actual reduction potentials because the chemical conditions at their surfaces are different.

A voltmeter measures the difference between these actual potentials, not simply the difference between two tabulated standard values.

This arrangement is called a concentration cell: a galvanic cell in which a difference in chemical concentration provides the driving force.

Why increasing concentration changes an electrode’s reduction tendency

Picture copper(II) ions interacting with a copper surface.

When the solution contains more copper(II) ions, reduction of these ions is more favourable relative to the reverse process under otherwise comparable conditions.

This is not simply because more ions produce more collisions.

Collision frequency can affect how quickly a reaction proceeds. Electrode potential instead describes the thermodynamic driving force for electron transfer.

Two cells can have the same potential difference but deliver different currents because their electrical resistance and reaction rates differ.

At the concentrated copper electrode, the greater reduction potential makes it the cathode.

At the dilute copper electrode, the lower reduction potential makes it the anode.

The potential difference favours a process that reduces the concentration difference:

  • Copper(II) ions are produced in the dilute solution.
  • Copper(II) ions are consumed in the concentrated solution.

As the concentrations approach one another, the driving force becomes smaller.

When the two copper(II)-ion activities become equal, the ideal concentration-cell potential reaches zero.

Three successive views of a copper concentration cell show two beakers connected by a salt bridge and external circuit. Initially, dilute and concentrated Cu2+ solutions have different ion densities. During discharge, copper dissolves at the original dilute-side electrode and deposits at the original concentrated-side electrode. Finally, the solutions have equal concentrations and the voltage reaches zero.
E°cell is zero, but unequal Cu²⁺ activities create a voltage that fades as copper transfers from the dilute-side electrode to the concentrated side.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

03What should a controlled measurement show?

The clearest test is to vary the ratio of the two copper(II)-ion concentrations while keeping the electrode materials and temperature unchanged.

For the following comparison, the red voltmeter lead always connects to the right electrode, and the black lead connects to the left.

Here is a set of theoretical predictions alongside deliberately constructed illustrative readings.

These are not measurements collected for this article. The invented readings demonstrate a pattern that an experiment could test.

TrialLeft \([\mathrm{Cu}^{2+}]\), mol L⁻¹Right \([\mathrm{Cu}^{2+}]\), mol L⁻¹Ideal voltageIllustrative reading
A0.0500.0500.0000 V+0.001 V
B0.0100.100+0.0296 V+0.028 V
C0.1000.010−0.0296 V−0.027 V
D0.0200.200+0.0296 V+0.028 V

Consider what each comparison is testing.

Trial A: Equal concentrations

Both copper electrodes experience the same chemical conditions.

The ideal potential difference is zero.

A small non-zero laboratory reading might arise from measurement offset, junction potentials, surface conditions, or experimental uncertainty. It would not automatically demonstrate a genuine concentration-cell voltage.

Trials B and C: Reversing the concentration difference

In Trial B, the concentrated half-cell is on the right.

The right electrode is the positive cathode, so the voltmeter reads a positive voltage.

In Trial C, the concentrations are reversed without changing the voltmeter leads.

The left electrode becomes the cathode.

The ideal reading changes sign.

This reversal is useful evidence because it connects the polarity to the concentration difference rather than to a permanent property of either copper strip.

Trials B and D: Changing both concentrations together

Trial D has twice the concentration in each beaker compared with Trial B.

Yet the ideal voltage is unchanged.

Why?

Because both trials have the same concentration ratio:

\[ \frac{c_{\mathrm{right}}}{c_{\mathrm{left}}}=10 \]

Under the ideal model, the two electrode-potential changes cancel when both concentrations are multiplied by the same factor.

This exposes an important misconception.

A concentration cell does not respond to the total amount of dissolved copper(II) ions in a simple way. Its ideal open-circuit potential depends on the ratio of their activities.

The amount of solution still matters for how much charge the cell can eventually supply. We’ll return to that distinction in Question 5.

What the illustrative readings would not prove

Suppose a real experiment followed the general pattern but gave readings slightly different from the predictions.

That would support the concentration model qualitatively, but it would not prove that concentration was the only influence.

A better investigation would:

  1. Establish an equal-concentration baseline with the same voltmeter and electrode materials.
  2. Change one solution concentration while keeping the other fixed.
  3. Keep temperature, electrode preparation, and measurement conditions as consistent as possible.
  4. Swap the concentrated and dilute solutions to test whether the polarity reverses.
  5. Repeat the measurements using a suitable salt bridge and check for systematic instrument error.

An appropriate concentrated potassium nitrate bridge can reduce liquid-junction effects, although it cannot remove every non-ideal contribution.

The central experimental decision is to distinguish a reproducible concentration effect from a change caused by the apparatus.

04Quantifying the concentration effect

We can now put a number on the difference.

For NSW students studying the Chemistry Stage 6 Syllabus (2017), the essential course knowledge includes redox half-equations, standard reduction potentials, and galvanic-cell investigations. The logarithmic relationship used below is an extension for calculating non-standard potentials, not a formula you need to memorise for that syllabus.

The 2025 Chemistry syllabus is scheduled to begin implementation in 2028.

The Nernst equation

The Nernst equation relates actual cell potential to standard potential and the composition of the reacting system.

At \(25^\circ\mathrm{C}\):

\[ E=E^\circ-\frac{0.0592\ \mathrm{V}}{n}\log_{10}Q \]

Here:

  • \(E\) is the actual cell potential, in volts.
  • \(E^\circ\) is the standard cell potential, in volts.
  • \(n\) is the number of moles of electrons transferred per mole of the reaction as written.
  • \(Q\) is the dimensionless reaction quotient.
  • \(\log_{10}\) means the base-10 logarithm.

The numerical factor \(0.0592\ \mathrm{V}\) applies at approximately \(25^\circ\mathrm{C}\).

For our copper concentration cell, \(n=2\), and \(E^\circ=0\ \mathrm{V}\).

When the cell discharges spontaneously, the concentrated solution supplies copper(II) ions for reduction and the dilute solution receives copper(II) ions from oxidation.

The idealised reaction quotient is:

\[ Q\approx\frac{c_{\mathrm{dilute}}} {c_{\mathrm{concentrated}}} \]

Here \(c\) represents concentration in \(\mathrm{mol\,L^{-1}}\). The concentration units cancel in the ratio.

Substituting gives:

\[ E\approx0.0296\ \mathrm{V}\, \log_{10}\left( \frac{c_{\mathrm{concentrated}}} {c_{\mathrm{dilute}}} \right) \]

This expression gives a positive potential when the concentrated electrode is treated as the cathode.

For the signed voltmeter reading with its red lead on the right and black lead on the left, use:

\[ V_{R-L}\approx0.0296\ \mathrm{V}\, \log_{10}\left(\frac{c_R}{c_L}\right) \]

Here \(c_R\) and \(c_L\) are the copper(II)-ion concentrations in the right and left beakers respectively.

This form allows the result to be negative if the more concentrated solution is on the left.

Copper concentration cell with dilute and concentrated copper(II) solutions, copper electrodes, a salt bridge, and a voltmeter with its red lead on the right. A logarithmic voltage graph shows the polarity reversal at equal concentrations.
With the red lead on the right, the ideal Nernst curve crosses zero at equal copper(II)-ion concentrations, reversing the voltmeter polarity.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Worked example: Which beaker plates copper?

A copper concentration cell operates at \(25^\circ\mathrm{C}\). The left half-cell contains \(0.0100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\), while the right contains \(0.0500\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\). A potassium nitrate salt bridge joins the solutions. The voltmeter’s red lead is connected to the right electrode.

Calculate the ideal cell potential and identify the direction of electron flow when the cell supplies current.

Step 1

The right solution has the higher copper(II)-ion concentration.

Therefore, the right copper electrode is the cathode, and the left is the anode.

Step 2

\[ \frac{c_R}{c_L} =\frac{0.0500}{0.0100} =5.00 \]

The ratio is dimensionless.

Step 3

\[ \begin{aligned} E&=0.0296\log_{10}(5.00)\\ &=0.0296(0.699)\\ &=+0.0207\ \mathrm{V} \end{aligned} \]

The coefficient has units of volts, so the result is in volts.

Step 4

The predicted high-resistance voltmeter reading is approximately \(+0.0207\ \mathrm{V}\).

When the cell supplies current, electrons flow from the left electrode to the right electrode through the external circuit.

Copper dissolves at the left electrode and deposits at the right.

The cell’s voltage is small, but it is not zero. The concentration difference provides the driving force.

Two copper electrodes dip into separate Cu²⁺ solutions, joined by a potassium nitrate salt bridge. A voltmeter connects to the left electrode with its black lead and the right electrode with its red lead.
Schematic Cu²⁺ markers show greater particle density on the right; a KNO₃ bridge joins the copper electrodes, wired to a voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Worked example: Finding an unknown concentration from a voltage

A second copper concentration cell operates at \(25^\circ\mathrm{C}\).

The right half-cell has a known copper(II)-ion concentration of \(0.0800\ \mathrm{mol\,L^{-1}}\). The left contains an unknown copper(II)-ion concentration.

With the red voltmeter lead on the right and black lead on the left, the ideal model predicts a reading of \(+0.0178\ \mathrm{V}\).

Calculate the unknown concentration.

Step 1

The positive reading means that the right electrode has the higher potential.

For two copper electrodes under the stated assumptions, the right solution therefore has the higher copper(II)-ion concentration.

Define the concentration ratio:

\[ r=\frac{c_R}{c_L} \]

Step 2

\[ 0.0178=0.0296\log_{10}r \]

Therefore:

\[ \begin{aligned} \log_{10}r&=\frac{0.0178}{0.0296}\\ &=0.601\\ r&=10^{0.601}\\ &\approx3.99 \end{aligned} \]

Step 3

\[ \begin{aligned} c_L&=\frac{0.0800}{3.99}\\ &\approx0.0200\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The left solution has an estimated copper(II)-ion concentration of \(0.0200\ \mathrm{mol\,L^{-1}}\).

Step 4

The potential reveals a concentration ratio of approximately \(4:1\).

It does not independently determine both concentrations.

We could calculate the unknown because the right concentration was already known. If both were unknown, one voltage reading would not provide enough information to find both separately.

In practice, an accurate concentration measurement would also require calibration and allowance for non-ideal solution behaviour.

Two copper half-cells are connected by a KNO₃ salt bridge. The left beaker contains an unknown Cu²⁺ concentration and the right contains 0.0800 mol L⁻¹ Cu²⁺. Black and red voltmeter leads connect to the left and right copper electrodes respectively, displaying +0.0178 V.
The cell compares an unknown Cu²⁺ solution with a 0.0800 mol L⁻¹ reference while the voltmeter reads +0.0178 V.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

05Why dilution does not always lower the voltage

A common prediction is that diluting an electrolyte must reduce a galvanic cell’s voltage.

That sounds reasonable if you think more ions always mean a stronger cell.

But the outcome depends on which species is diluted and what that species does in the overall cell reaction.

Consider a different cell with a zinc electrode in zinc sulfate solution and a copper electrode in copper sulfate solution.

Its overall reaction is:

\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]

The standard cell potential is approximately \(+1.10\ \mathrm{V}\).

If \([\mathrm{Zn}^{2+}]\) is held at \(0.100\ \mathrm{mol\,L^{-1}}\) and \([\mathrm{Cu}^{2+}]\) is reduced from \(0.100\) to \(0.0100\ \mathrm{mol\,L^{-1}}\), the reaction quotient increases from 1 to 10.

The ideal Nernst prediction becomes:

\[ \begin{aligned} E&=1.10-0.0296\log_{10}(10)\\ &=1.10-0.0296\\ &\approx+1.07\ \mathrm{V} \end{aligned} \]

The potential decreases.

Copper(II) ions are reactants in the spontaneous zinc-copper reaction, so reducing their concentration makes the forward reaction less favourable.

But the cell does not suddenly reverse direction. Its potential remains strongly positive under these conditions.

The copper concentration cell is different because its standard cell potential is zero. A concentration difference alone can determine which electrode becomes the cathode.

Side-by-side galvanic cells. The left concentration cell has two copper electrodes in dilute and concentrated CuSO₄, with visibly different Cu²⁺ particle densities. The right cell has a zinc strip in ZnSO₄ and a copper strip in CuSO₄. Both have U-shaped salt bridges, external connecting wires and polarity-marked voltmeters.
A concentration cell generates voltage from unequal Cu²⁺ concentrations despite identical electrodes, while a zinc–copper cell combines different metals and their corresponding ion solutions.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

For a broader explanation of why practical conditions affect galvanic-cell readings, see Why a Galvanic Cell’s Measured Voltage Differs from E°.

For concentration questions, use this decision process:

  1. Write the two electrode half-reactions and identify oxidation and reduction.
  2. Identify which dissolved ions are produced and which are consumed.
  3. Predict whether the concentration change favours or opposes the forward reaction.
  4. Keep the standard potential separate from the actual potential.
  5. Use the concentration ratio, and the Nernst equation if supplied, to estimate the size and sign of the change.
  6. Check whether the voltmeter’s lead orientation matches the sign you have calculated.

That sequence prevents two errors: assuming every dilution lowers voltage, and treating a tabulated standard potential as an exact practical reading.

06Questions and solutions

For the following questions, assume the cells operate at \(25^\circ\mathrm{C}\) and that concentration ratios approximate activity ratios.

Unless a question states otherwise, assume suitable salt bridges, negligible liquid-junction potentials, and high-resistance voltage measurements. Treat calculated potentials as ideal predictions.

When required, use:

\[ E=E^\circ-\frac{0.0592\ \mathrm{V}}{n}\log_{10}Q \]

For copper concentration cells:

\[ V_{R-L}=0.0296\ \mathrm{V}\, \log_{10}\left(\frac{c_R}{c_L}\right) \]

The signed reading \(V_{R-L}\) assumes the red voltmeter lead is connected to the right electrode and the black lead to the left.

Question 1

A concentration cell contains two silver electrodes immersed in separate silver nitrate solutions.

The left half-cell contains \(0.0100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Ag}^{+}\), and the right contains \(0.100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Ag}^{+}\). A potassium nitrate salt bridge connects the solutions.

The red voltmeter lead is connected to the right electrode.

The reduction half-equation is:

\[ \ce{Ag+(aq) + e- -> Ag(s)} \]

Identify the anode and cathode, write the oxidation half-equation, calculate the ideal cell potential, and state the direction of electron flow when the cell supplies current.

Two silver electrodes immersed in separate silver nitrate solutions: the left contains 0.0100 mol L⁻¹ Ag⁺ and the right 0.100 mol L⁻¹ Ag⁺. A violet potassium nitrate U-shaped salt bridge connects the beakers. Black and red leads connect the left and right electrodes respectively to a digital voltmeter with a blank display.
Two silver half-cells with different Ag⁺ concentrations are joined by a KNO₃ salt bridge and connected to a blank voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 1

The left silver electrode is the anode, the right electrode is the cathode, and the ideal voltmeter reading is \(+0.0592\ \mathrm{V}\).

The right solution contains more silver ions, so reduction is favoured there relative to the dilute half-cell.

Oxidation occurs on the left:

\[ \ce{Ag(s) -> Ag+(aq) + e-} \]

Reduction occurs on the right:

\[ \ce{Ag+(aq) + e- -> Ag(s)} \]

The standard potential difference is zero because both electrodes use the same silver half-reaction.

For silver, \(n=1\).

\[ \begin{aligned} E&=0.0592\log_{10} \left(\frac{0.100}{0.0100}\right)\\ &=0.0592\log_{10}(10)\\ &=+0.0592\ \mathrm{V} \end{aligned} \]

Electrons flow from the dilute left electrode to the concentrated right electrode through the external circuit when current is drawn.

A tempting mistake is to use \(n=2\) because the earlier examples involved copper. The electron number must come from the actual half-reaction. Silver ions accept one electron each, so the ideal voltage for a tenfold concentration ratio is twice the corresponding copper concentration-cell voltage.

Question 2

Two copper concentration half-cells initially contain 100 mL of solution each.

  • Left: \(0.0100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\).
  • Right: \(0.100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\).

The cell is disconnected from its external circuit.

A student simultaneously removes 60 mL from each beaker, transfers those portions into the opposite beakers, and thoroughly mixes both solutions. No solution is lost, and neither electrode reacts during the exchange.

The student then reconnects the voltmeter with the red lead still on the right.

Determine the final concentration in each beaker, calculate the ideal voltmeter reading, and explain whether the electron-flow direction has changed.

Two copper half-cells contain 100 mL of CuSO₄ solution each. The left starts at 0.0100 mol L⁻¹ and the right at 0.100 mol L⁻¹. Copper strips and a salt bridge connect the beakers, while opposing arrows show simultaneous transfers of 60 mL and an open external circuit.
The labelled concentrations are the starting solutions; equal 60 mL portions move in opposite directions while the external circuit remains open.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 2

The final concentrations are \(0.0640\ \mathrm{mol\,L^{-1}}\) on the left and \(0.0460\ \mathrm{mol\,L^{-1}}\) on the right. The ideal voltmeter reading becomes approximately \(-0.00425\ \mathrm{V}\), so the electron-flow direction reverses.

The key is that exchanging more than half of each solution reverses which beaker is more concentrated.

After the simultaneous exchange, each beaker contains 40% of its original solution and 60% from the other beaker.

For the left beaker:

\[ \begin{aligned} c_L&=0.4(0.0100)+0.6(0.100)\\ &=0.0640\ \mathrm{mol\,L^{-1}} \end{aligned} \]

For the right beaker:

\[ \begin{aligned} c_R&=0.4(0.100)+0.6(0.0100)\\ &=0.0460\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The more concentrated solution is now on the left.

Calculate the signed reading:

\[ \begin{aligned} V_{R-L}&=0.0296\log_{10} \left(\frac{0.0460}{0.0640}\right)\\ &=0.0296\log_{10}(0.71875)\\ &\approx-0.00425\ \mathrm{V} \end{aligned} \]

The units are volts.

The red lead is still connected to the right, but the right electrode is now the lower-potential electrode.

When the cell supplies current, electrons therefore flow from right to left.

The original concentration difference was larger, so the original ideal voltage was approximately \(+0.0296\ \mathrm{V}\). Mixing reduces the difference substantially, but exchanging 60% of the liquids also reverses its direction.

A student might expect any exchange of the two solutions to move the voltage towards zero without reversing it. That would be true for exchanges of less than half the volume, but not for this arrangement.

At an exchange of exactly 50%, both final solutions would have the same concentration, producing an ideal potential of zero.

Question 3

A student investigates a copper concentration cell using a high-resistance voltmeter.

In Trial A:

  • Left: \(0.0100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\).
  • Right: \(0.100\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\).
  • Voltmeter reading: \(+0.0336\ \mathrm{V}\).

In Trial B, the student swaps the two solutions but leaves the voltmeter leads connected to the same physical electrodes.

The reading becomes \(-0.0256\ \mathrm{V}\).

The student proposes a model in which the true cell potential reverses sign between trials, but the voltmeter has a fixed zero offset that remains unchanged.

Assuming this model is valid and other voltage contributions are negligible:

  1. Determine the magnitude of the true concentration-cell voltage and the voltmeter offset.
  2. Predict the reading if both half-cells contain \(0.0500\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\).
  3. Explain how the student could test the proposed offset experimentally, and identify one limitation of this model.
Two side-by-side copper concentration cells with identical U-shaped salt bridges and high-resistance voltmeters. Trial A has 0.0100 mol L⁻¹ Cu²⁺ on the left and 0.100 mol L⁻¹ on the right; Trial B swaps them. Red leads remain connected to the physical right electrodes. Readings are +0.0336 V and −0.0256 V.
The paired cells show the concentration swap while the red lead stays attached to the same physical right-hand copper electrode.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 3

Under the proposed model, the true concentration-cell voltage has a magnitude of \(0.0296\ \mathrm{V}\), and the voltmeter has a fixed positive offset of \(0.0040\ \mathrm{V}\). Equal concentrations would therefore produce a displayed reading of \(+0.0040\ \mathrm{V}\).

Let \(E\) be the positive magnitude of the true concentration-cell potential and \(b\) the fixed meter offset.

Trial A gives:

\[ E+b=0.0336\ \mathrm{V} \]

Trial B gives:

\[ -E+b=-0.0256\ \mathrm{V} \]

Subtract the equations to eliminate \(b\):

\[ \begin{aligned} 2E&=0.0336-(-0.0256)\\ &=0.0592\ \mathrm{V}\\ E&=0.0296\ \mathrm{V} \end{aligned} \]

Substitute into Trial A:

\[ \begin{aligned} b&=0.0336-0.0296\\ &=+0.0040\ \mathrm{V} \end{aligned} \]

This is consistent with the ideal Nernst prediction for a tenfold concentration difference.

If both half-cells have equal concentrations, the true concentration-cell potential should be zero.

The proposed model therefore predicts:

\[ V_{\mathrm{display}}=0+0.0040 =+0.0040\ \mathrm{V} \]

A useful test is to connect both voltmeter inputs to the same electrical conductor, so that the applied potential difference is zero. A persistent \(+0.0040\ \mathrm{V}\) reading would support the proposed meter-offset explanation.

The student could also repeat the equal-concentration cell measurement.

However, the original two readings alone do not prove that the difference is caused entirely by the voltmeter.

Liquid-junction potentials, changes in ion activity, and electrode-surface effects can alter practical readings. Some contributions may also change when the solutions are swapped.

The tempting conclusion is that the larger positive reading in Trial A means the concentration effect is stronger in that direction. Under the stated symmetric model, the true concentration-driven potential has the same magnitude in both directions. A constant positive offset explains the different displayed magnitudes.

Question 4

A copper concentration cell contains two 100 mL solutions at \(25^\circ\mathrm{C}\).

One solution initially contains \(0.0200\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\), and the other contains \(0.0800\ \mathrm{mol\,L^{-1}}\) \(\mathrm{Cu}^{2+}\). The student has forgotten which concentration belongs to which beaker.

The red voltmeter lead is connected to the left electrode, and the black lead to the right.

The initial ideal voltage is approximately \(+0.0178\ \mathrm{V}\).

The cell is then allowed to discharge. After a period of operation:

  • The left copper electrode has gained \(0.0635\ \mathrm{g}\).
  • The right copper electrode has lost \(0.0635\ \mathrm{g}\).

Assume no mixing between the half-cells, negligible volume changes, and that the electrode reactions are the only processes changing the copper(II)-ion concentrations.

The molar mass of copper is \(63.5\ \mathrm{g\,mol^{-1}}\).

Determine the original concentration of each half-cell, calculate the final concentrations and ideal voltage, and explain why the voltage changes in that direction.

Two 100 mL CuSO₄ beakers connected by a U-shaped salt bridge and copper electrodes wired to a voltmeter. The red lead connects to the left electrode and the black lead to the right. The left strip gained 0.0635 g of copper and the right strip lost 0.0635 g. The possible starting concentrations, 0.0200 and 0.0800 mol L⁻¹, are shown separately as unassigned values.
At 25 °C, the connected copper half-cells show the measured electrode mass changes during a concentration-cell discharge.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 4

The left solution was initially \(0.0800\ \mathrm{mol\,L^{-1}}\), while the right was \(0.0200\ \mathrm{mol\,L^{-1}}\). After discharge, their concentrations become \(0.0700\) and \(0.0300\ \mathrm{mol\,L^{-1}}\), respectively, and the ideal voltage decreases to approximately \(+0.0109\ \mathrm{V}\).

The original positive voltmeter reading means the left electrode had the higher reduction potential.

This identifies the left electrode as the cathode, consistent with its observed increase in mass.

Copper(II) ions were reduced and deposited there:

\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]

The right electrode lost mass because copper metal was oxidised:

\[ \ce{Cu(s) -> Cu^2+(aq) + 2e-} \]

Now calculate how much copper was transferred through the electrode reactions.

\[ \begin{aligned} n(\ce{Cu})&=\frac{m}{M}\\ &=\frac{0.0635\ \mathrm{g}} {63.5\ \mathrm{g\,mol^{-1}}}\\ &=0.00100\ \mathrm{mol} \end{aligned} \]

Each half-cell has a volume of \(0.100\ \mathrm{L}\).

The corresponding concentration change is:

\[ \begin{aligned} \Delta c&=\frac{n}{V}\\ &=\frac{0.00100}{0.100}\\ &=0.0100\ \mathrm{mol\,L^{-1}} \end{aligned} \]

At the left cathode, copper(II) ions are consumed:

\[ \begin{aligned} c_{L,\mathrm{final}} &=0.0800-0.0100\\ &=0.0700\ \mathrm{mol\,L^{-1}} \end{aligned} \]

At the right anode, copper(II) ions are produced:

\[ \begin{aligned} c_{R,\mathrm{final}} &=0.0200+0.0100\\ &=0.0300\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The red lead is connected to the left electrode, so the signed potential is calculated using \(c_L/c_R\).

\[ \begin{aligned} V_{L-R}&=0.0296\log_{10} \left(\frac{0.0700}{0.0300}\right)\\ &=0.0296\log_{10}(2.333)\\ &\approx+0.0109\ \mathrm{V} \end{aligned} \]

The cell remains capable of spontaneous discharge in the original direction because the left solution is still more concentrated.

However, the concentration difference has decreased, so the driving force and ideal voltage are smaller.

The subtle mistake is to assume that because the left electrode gains copper metal, its solution must become more concentrated.

Exactly the opposite happens.

Copper deposits onto the electrode by removing \(\mathrm{Cu}^{2+}\) from the solution. The metal becomes heavier while the surrounding solution becomes less concentrated.

Question 5

Two ideal copper concentration cells are built using identical copper electrodes and potassium nitrate salt bridges.

Both operate at \(25^\circ\mathrm{C}\).

Each cell starts with a dilute copper(II)-ion solution on the left and a concentrated solution on the right.

PropertyCell ACell B
Left concentration0.0100 mol L⁻¹0.0100 mol L⁻¹
Right concentration0.100 mol L⁻¹0.100 mol L⁻¹
Left solution volume100 mL20.0 mL
Right solution volume100 mL180 mL
Total solution volume200 mL200 mL

Both cells have excess copper metal and operate without side reactions.

Assume the solution volumes remain constant, copper(II) ions do not mix directly between the half-cells, and the cells can discharge reversibly until their concentration differences disappear.

Use the Faraday constant:

\[ F=96485\ \mathrm{C\,mol^{-1}} \]

Here \(F\) represents the electric charge carried by one mole of electrons.

A student makes the following argument:

“Cell B starts with more copper(II) ions in total. Both cells have the same initial voltage, so Cell B must be able to deliver more charge before its voltage reaches zero.”

Determine whether the student is correct.

Calculate the initial ideal voltage of each cell and the maximum theoretical charge each can deliver before its two solutions reach equal concentrations.

Explain why the result is consistent with the concentration-cell model.

Side-by-side copper concentration cells with copper electrodes, KNO₃ salt bridges and red voltmeter leads. Both use 0.0100 mol L⁻¹ dilute solution on the left and 0.100 mol L⁻¹ concentrated solution on the right. Cell A has 100 mL in each beaker; Cell B has 20.0 mL and 180 mL respectively.
Both setups connect dilute and concentrated copper(II) solutions; the beaker fills show their different starting volumes.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 5

The student’s conclusion is incorrect. Both cells have the same initial ideal voltage, \(+0.0296\ \mathrm{V}\), but Cell A can deliver approximately \(868\ \mathrm{C}\), while Cell B can deliver only approximately \(313\ \mathrm{C}\) before the ideal concentration difference disappears.

Cell B contains more copper(II) ions initially, yet has the smaller theoretical charge capacity.

The first step is to recognise what determines the initial voltage.

Both cells have the same concentration ratio:

\[ \frac{c_R}{c_L} =\frac{0.100}{0.0100}=10 \]

Therefore:

\[ \begin{aligned} E_A&=0.0296\log_{10}(10)\\ &=+0.0296\ \mathrm{V}\\ E_B&=0.0296\log_{10}(10)\\ &=+0.0296\ \mathrm{V} \end{aligned} \]

So the student is correct about the initial voltage.

The mistake occurs when using that voltage to predict the amount of charge available.

Voltage measures the present driving force, not the total quantity of reaction that can occur.

For both cells, spontaneous discharge causes:

  • Copper to dissolve at the dilute anode.
  • Copper(II) ions to be consumed at the concentrated cathode.
  • The two concentrations to approach one another.

For every mole of copper oxidised at the dilute electrode, one mole of copper(II) ions is consumed at the concentrated electrode.

Therefore, the total number of moles of dissolved copper(II) ions across the two beakers remains constant under the stated assumptions.

The ideal limiting condition occurs when the two final concentrations are equal.

Cell A

Calculate the total initial copper(II)-ion amount:

\[ \begin{aligned} n_{\mathrm{total}} &=(0.0100)(0.100)\\ &\quad +(0.100)(0.100)\\ &=0.0110\ \mathrm{mol} \end{aligned} \]

The total solution volume is \(0.200\ \mathrm{L}\).

When the concentrations become equal, their common value must be:

\[ \begin{aligned} c_{\mathrm{final}} &=\frac{0.0110}{0.200}\\ &=0.0550\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The dilute half-cell rises from \(0.0100\) to \(0.0550\ \mathrm{mol\,L^{-1}}\).

The amount of copper oxidised is therefore:

\[ \begin{aligned} n(\ce{Cu}) &=(0.0550-0.0100)(0.100)\\ &=0.00450\ \mathrm{mol} \end{aligned} \]

Each copper atom releases two electrons.

Thus:

\[ \begin{aligned} n(e^-)&=2(0.00450)\\ &=0.00900\ \mathrm{mol} \end{aligned} \]

The maximum theoretical charge is:

\[ \begin{aligned} q_A&=n(e^-)F\\ &=(0.00900)(96485)\\ &\approx868\ \mathrm{C} \end{aligned} \]

Cell B

Calculate its total initial copper(II)-ion amount:

\[ \begin{aligned} n_{\mathrm{total}} &=(0.0100)(0.0200)\\ &\quad +(0.100)(0.180)\\ &=0.0182\ \mathrm{mol} \end{aligned} \]

Cell B indeed contains more copper(II) ions than Cell A.

Its total solution volume is also \(0.200\ \mathrm{L}\).

The common final concentration is:

\[ \begin{aligned} c_{\mathrm{final}} &=\frac{0.0182}{0.200}\\ &=0.0910\ \mathrm{mol\,L^{-1}} \end{aligned} \]

The dilute half-cell needs to rise from \(0.0100\) to \(0.0910\ \mathrm{mol\,L^{-1}}\).

That seems like a much larger concentration change.

But the dilute compartment is only \(0.0200\ \mathrm{L}\).

The amount of copper oxidised is:

\[ \begin{aligned} n(\ce{Cu}) &=(0.0910-0.0100)(0.0200)\\ &=0.00162\ \mathrm{mol} \end{aligned} \]

The electron amount is:

\[ \begin{aligned} n(e^-)&=2(0.00162)\\ &=0.00324\ \mathrm{mol} \end{aligned} \]

Therefore:

\[ \begin{aligned} q_B&=n(e^-)F\\ &=(0.00324)(96485)\\ &\approx313\ \mathrm{C} \end{aligned} \]

Compare the results:

QuantityCell ACell B
Initial ideal voltage+0.0296 V+0.0296 V
Initial total \(\mathrm{Cu}^{2+}\)0.0110 mol0.0182 mol
Final equal concentration0.0550 mol L⁻¹0.0910 mol L⁻¹
Maximum theoretical charge868 C313 C

Cell B has the greater total copper(II)-ion amount but the smaller available charge.

Why?

Because its dilute compartment is much smaller.

Only a relatively small amount of copper needs to dissolve into that small volume before its concentration becomes close to the concentration in the much larger right compartment.

Once the concentrations equalise, the driving force vanishes.

The cell still contains copper metal and dissolved copper(II) ions. It has not exhausted either substance.

It has exhausted the concentration difference that was driving the reaction.

That is the conceptual hinge: equal concentration is the stopping condition, not equal numbers of ions, and not the complete consumption of a reactant.

The theoretical charge values assume reversible discharge approaching equilibrium. A practical cell under load would show additional voltage losses and might stop delivering useful current earlier.

07What the concentration-cell experiment really tells us

The copper concentration cell demonstrates something that a standard reduction-potential table cannot show by itself.

Two half-cells can have identical standard reduction potentials and still produce a measurable potential difference when their ion activities differ.

Concentration affects the relative favourability of oxidation and reduction. The resulting voltage depends on the concentration ratio, the electrode reactions, the temperature, and how the measurement is made.

It is useful to keep three quantities separate:

QuantityWhat it tells you
Standard cell potential, \(E^\circ_{\mathrm{cell}}\)The reference potential under standard conditions
Actual cell potential, \(E_{\mathrm{cell}}\)The driving force under the present chemical conditions, ideally measured near open circuit
Charge available before the concentration difference disappearsHow much electron transfer can occur as the system approaches equal activities

A concentration-cell voltmeter can be useful for comparing an unknown solution with a known reference. But without a reference concentration, the voltage alone gives a ratio, not two absolute concentrations.

And even if the concentration difference predicts a non-zero potential, the cell still needs a suitable ionic pathway to supply sustained current.

That leads to the next experimental question: Which Ions Move Through a Salt Bridge in a Galvanic Cell?. Understanding that movement explains how the electrode reactions can continue without the solutions becoming electrically unbalanced.