Why the Last Drops of Titrant Should Be Added Slowly
Learn why titrant must be added drop by drop near the endpoint, how to prepare titration apparatus correctly, and how overshooting affects your results. Includes worked examples tracing experimental errors through to calculated acid concentrations.
You’re one drop away from the endpoint. The solution in the conical flask is almost the right colour, but you add another few millilitres in one go. Suddenly, the colour changes permanently. You’ve overshot.
This is why the last drops of titrant should be added slowly: as you approach the endpoint, adding titrant drop by drop gives you control over the volume delivered and time to observe the indicator’s colour change. It reduces the risk of adding excess titrant and recording a titre that is too large.
The important part is knowing exactly when to slow down, how your apparatus affects the measured volume, and what happens to your final concentration if you overshoot.
01Why the final drops matter
Imagine adding acid from a burette to a flask containing an alkali and a few drops of indicator.
At the beginning, the flask contains plenty of alkali. Each addition of acid reacts with some of it, so the indicator retains its original colour. You can add the acid relatively quickly.
As the reaction approaches completion, however, very little alkali remains. A small additional volume of acid can now make a substantial difference to the composition of the flask.
The endpoint is the observed indicator colour change that signals you should stop adding titrant. It is used to estimate the equivalence point, where the reactants have been added in the stoichiometric proportions specified by the balanced chemical equation.
These points are related, but they are not identical. The indicator changes colour over a particular pH range, so the observed endpoint may occur slightly before or after the equivalence point.
What happens as you approach the endpoint?
Consider a titration in which hydrochloric acid is added to sodium hydroxide using phenolphthalein as the indicator.
The reaction is:
\[ \ce{HCl + NaOH -> NaCl + H2O} \]
Phenolphthalein is pink in alkaline solution and colourless in sufficiently acidic solution.
| Stage | What you observe | How quickly to add titrant |
|---|---|---|
| Early titration | Pink colour remains after swirling | Relatively quickly |
| Approaching endpoint | Pink colour becomes less intense or takes longer to return after swirling | Slowly, in small portions |
| Very close to endpoint | A small drop produces a temporary colour change | One drop at a time |
| Endpoint reached | The solution becomes colourless and remains that way after swirling | Stop immediately |
Why not keep adding acid until you’re certain there is absolutely no pink anywhere?
Because the endpoint has already been reached when the colour change becomes persistent throughout the solution after thorough swirling. Further acid does not make the result more accurate. It simply increases the measured titre.
Why swirling matters as much as adding slowly
A drop of titrant does not instantly mix throughout the flask. It initially enters a small region of solution, where its concentration is much higher than in the rest of the flask.
Swirling distributes the titrant throughout the solution and allows the reaction to proceed before you decide whether another drop is needed.
Without swirling, you might see a localised colour change near the point where the drop enters the flask and mistake it for the endpoint. Alternatively, you might add more titrant before the previous addition has mixed completely.
The correct sequence near the endpoint is:
- Add one drop of titrant.
- Swirl the conical flask thoroughly.
- Allow the colour to become uniform.
- Observe whether the colour change persists.
- If the original colour returns, add another drop and repeat.
- If the endpoint colour persists, stop.
This is a decision based on the solution after mixing, not the colour immediately surrounding the falling drop.
02Before the titration: condition the apparatus
Adding the final drops carefully won’t help if the solutions entering your flask have the wrong concentrations or volumes.
This is where apparatus conditioning comes in. Conditioning means rinsing the inside of volumetric equipment with a small amount of the solution that it will actually contain or transfer.
The aim is to remove residual water that could dilute your solutions.
1. Condition the burette with the titrant
The burette contains the titrant, which is the solution of known concentration.
Suppose you are using \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
After washing the burette with distilled water:
- Allow the water to drain.
- Add a small amount of the sodium hydroxide solution.
- Rotate the burette so the solution rinses the internal walls.
- Open the stopcock and allow some solution to pass through the tip.
- Discard the rinse and repeat if necessary.
- Fill the burette with the sodium hydroxide solution.
The final rinse through the tip is important. It removes residual water from the stopcock and delivery tip, as well as the main tube.
What happens if you skip this step?
The residual water dilutes the sodium hydroxide. Its actual concentration becomes lower than the labelled concentration.
You now need a larger volume to deliver the same number of moles of hydroxide ions. If you calculate using the original labelled concentration, you will overestimate the concentration of the unknown acid.
This is a systematic error: repeating the titration won’t automatically remove it.
2. Condition the pipette with the analyte
The volumetric pipette transfers a fixed volume of the solution being analysed, called the analyte.
If you are transferring \(25.00\text{ mL}\) of hydrochloric acid, rinse the pipette with a small amount of that hydrochloric acid before taking your sample.
Why?
Residual water inside the pipette dilutes the acid being transferred. The pipette still delivers a total volume of \(25.00\text{ mL}\), but that volume contains fewer moles of acid than expected.
The titre will therefore be smaller.
There is another important detail when transferring the solution:
- Allow the pipette to drain under gravity.
- Touch its tip against the inside wall of the conical flask.
- Allow the specified drainage time.
- Do not blow out the remaining liquid unless the pipette is specifically designed as a blow-out pipette.
A standard volumetric pipette is calibrated to deliver its stated volume while retaining a small amount of liquid in the tip. Forcing that remaining liquid out can transfer extra analyte and increase the titre.
3. The conical flask is different
Here’s a common trap.
You can rinse the conical flask with distilled water and use it while it is still wet. You do not need to condition it with the analyte.
Why is this different?
The pipette has already transferred a fixed number of moles of analyte into the flask. Adding distilled water increases the total volume of liquid, but it does not change the number of moles present.
The amount of titrant required to reach equivalence therefore stays the same.
Compare the three situations:
| Where the water remains | What happens | Effect on titre |
|---|---|---|
| Burette | Dilutes the titrant | Increases |
| Pipette | Dilutes the transferred analyte | Decreases |
| Conical flask | Dilutes the mixture without changing analyte moles | Unchanged |
For a more detailed explanation of apparatus selection and preparation, see Choosing a Pipette and Burette for HSC Titrations.
03How an endpoint error changes your calculated concentration
Let’s connect the experimental mistake to the answer you actually write in an HSC calculation.
Assume the standard titrant is in the burette, the unknown analyte is in the conical flask, and the pipette transfers a fixed volume of analyte.
For a general reaction:
\[ aA+bT\rightarrow\text{products} \]
where:
- \(A\) is the analyte.
- \(T\) is the titrant.
- \(a\) and \(b\) are the balanced equation coefficients.
At equivalence:
\[ \frac{n(A)}{a}=\frac{n(T)}{b} \]
Using \(n=cV\), the analyte concentration is:
\[ c_A=\frac{a}{b}\times \frac{c_TV_T}{V_A} \]
Here, \(c_A\) and \(c_T\) are concentrations in \(\text{mol L}^{-1}\), while \(V_A\) and \(V_T\) are the analyte volume and titre, respectively, expressed in the same volume units.
The important relationship is:
\[ c_A\propto V_T \]
provided the other quantities remain correct.
In other words, a larger measured titre produces a larger calculated analyte concentration.
This gives us a useful error-tracing table.
| Experimental mistake | What happens to the titre? | Calculated analyte concentration |
|---|---|---|
| Endpoint overshot | Too large | Too high |
| Stop too early | Too small | Too low |
| Burette not conditioned | Too large | Too high |
| Pipette not conditioned | Too small | Too low |
| Ordinary pipette blown out | Too large | Too high |
| Extra distilled water in flask | Unchanged | Unchanged |
| Air bubble in burette tip at the initial reading | Too large | Too high |
These directions assume you use the labelled titrant concentration and nominal pipette volume in your calculation. If the actual titrant concentration is independently determined and used instead, the effect of dilution in the burette can be corrected.
Notice that the mistakes don’t all work in the same direction. You need to identify what physically changes before predicting the final answer.
For a complete method of tracing these errors through a concentration calculation, see How to Trace Titration Errors to the Final Concentration.
04Worked examples: understanding the effect of overshooting
Worked example: How much does a small overshoot change the concentration?
A \(25.00\text{ mL}\) sample of an unknown monoprotic acid is titrated with \(0.1000\text{ mol L}^{-1}\) sodium hydroxide. The endpoint is correctly reached at a titre of \(24.60\text{ mL}\).
A student continues adding sodium hydroxide until the total titre reaches \(24.75\text{ mL}\).
Assuming a \(1:1\) mole ratio, calculate the correct acid concentration, the concentration calculated from the overshot titre, and the percentage error.
Step 1
For a monoprotic acid, the reaction with sodium hydroxide has a \(1:1\) mole ratio.
\[ \ce{HA + NaOH -> NaA + H2O} \]
Step 2
Use \(n=cV\), converting the titre into litres.
\[ \begin{aligned} n(\ce{NaOH}) &=0.1000\times0.02460\\ &=0.002460\text{ mol} \end{aligned} \]
Step 3
The mole ratio is \(1:1\), so the acid contains \(0.002460\text{ mol}\).
\[ \begin{aligned} c(\ce{HA}) &=\frac{n}{V}\\ &=\frac{0.002460}{0.02500}\\ &=0.09840\text{ mol L}^{-1} \end{aligned} \]
Step 4
The student recorded \(24.75\text{ mL}\), rather than \(24.60\text{ mL}\).
\[ \begin{aligned} n(\ce{NaOH}) &=0.1000\times0.02475\\ &=0.002475\text{ mol} \end{aligned} \]
Therefore:
\[ c(\ce{HA})=\frac{0.002475}{0.02500} \]
\[ c(\ce{HA})=0.09900\text{ mol L}^{-1} \]
Step 5
\[ \begin{aligned} \%\text{ error} &=\frac{0.09900-0.09840}{0.09840} \times100\\ &=0.61\% \end{aligned} \]
The calculated concentration is approximately \(0.61\%\) too high.
The extra \(0.15\text{ mL}\) of sodium hydroxide was delivered after the endpoint. The student incorrectly treats all of that extra volume as though it were required to neutralise the acid.
This is exactly why you stop at the first persistent colour change.
Worked example: Why does the mole ratio matter when one extra drop is added?
A \(25.00\text{ mL}\) sample of sulfuric acid is titrated with \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
The balanced equation is:
\[ \ce{H2SO4 + 2NaOH -> Na2SO4 + 2H2O} \]
The correct endpoint occurs at \(24.60\text{ mL}\). However, the student adds two extra drops, each with an illustrative volume of \(0.050\text{ mL}\).
Calculate the correct sulfuric acid concentration, the concentration obtained from the overshot titre, and the percentage error.
Assume complete neutralisation to sulfate and an appropriate indicator.
Step 1
\[ V_{\text{extra}}=2\times0.050=0.100\text{ mL} \]
The recorded titre is:
\[ V_T=24.60+0.10=24.70\text{ mL} \]
Step 2
\[ \begin{aligned} n(\ce{NaOH}) &=0.1000\times0.02460\\ &=0.002460\text{ mol} \end{aligned} \]
Step 3
The mole ratio is \(1:2\), so one mole of sulfuric acid reacts with two moles of sodium hydroxide.
\[ n(\ce{H2SO4})=\frac{0.002460}{2} \]
\[ n(\ce{H2SO4})=0.001230\text{ mol} \]
Step 4
\[ \begin{aligned} c(\ce{H2SO4}) &=\frac{0.001230}{0.02500}\\ &=0.04920\text{ mol L}^{-1} \end{aligned} \]
Step 5
\[ \begin{aligned} n(\ce{NaOH}) &=0.1000\times0.02470\\ &=0.002470\text{ mol} \end{aligned} \]
The corresponding moles of sulfuric acid are:
\[ n(\ce{H2SO4})=\frac{0.002470}{2} =0.001235\text{ mol} \]
Therefore:
\[ \begin{aligned} c(\ce{H2SO4}) &=\frac{0.001235}{0.02500}\\ &=0.04940\text{ mol L}^{-1} \end{aligned} \]
Step 6
\[ \begin{aligned} \%\text{ error} &=\frac{0.04940-0.04920}{0.04920} \times100\\ &=0.41\% \end{aligned} \]
The calculated concentration is approximately \(0.41\%\) too high.
Notice that the two extra drops only added \(0.100\text{ mL}\) of titrant, but the resulting concentration is still affected.
The mole ratio changes the number of moles of acid represented by each additional mole of sodium hydroxide. You must use the balanced equation rather than assuming every acid-base titration has a \(1:1\) ratio.
05How to make the final endpoint decision
You now know why the last drops matter. But how do you decide exactly when to stop?
There are three things to get right.
1. Choose an appropriate indicator
An indicator changes colour over a particular pH range. You want that range to fall within the steep pH change around the equivalence point.
For example, in a weak acid-strong base titration, the equivalence point is above pH 7. Phenolphthalein is generally suitable because its transition range occurs within the steep pH change.
An indicator that changes colour well before the equivalence point will give you an endpoint that is too early. Adding titrant more slowly won’t fix that problem.
2. Look for the first permanent colour change
The correct endpoint is not necessarily the strongest colour you can produce.
For example, when sodium hydroxide is added to an acidic solution containing phenolphthalein:
- Before the endpoint, the solution is colourless.
- Near the endpoint, individual drops may produce temporary pink patches.
- After swirling, those patches disappear if more acid remains to react.
- At the endpoint, the first faint pink colour persists throughout the solution after swirling.
Stop at that first persistent pale pink.
If you continue until the whole flask is strongly pink, you’ve added excess sodium hydroxide.
The colour you want depends on which solution is in the burette. If hydrochloric acid is added to an alkaline solution containing phenolphthalein, the endpoint is instead the first permanent disappearance of the pink colour.
Don’t memorise a colour without considering the direction of the titration.
3. Use a rough titration to guide the accurate one
Your first titration should give you an approximate endpoint volume.
For example, suppose your rough titre is \(24.60\text{ mL}\).
In the next trial, you can add titrant relatively quickly until you are approaching that volume. Then slow down.
A sensible sequence is:
- Place the conical flask on a white tile so the colour is easy to see.
- Swirl continuously as titrant enters.
- Slow the addition as you approach the rough endpoint.
- Add individual drops, swirling after each one.
- If the colour disappears after swirling, continue carefully.
- Stop at the first colour change that persists throughout the solution.
If a drop lands on the inside wall of the flask rather than entering the main solution, wash it down with distilled water from a wash bottle. This does not change the moles of analyte; it simply brings the existing material into contact with the reacting solution.
If you overshoot, don’t try to reverse the endpoint by adding the other solution. Repeat the titration with a fresh aliquot.
One final point: concordant titres do not automatically prove that your endpoint is accurate. Repeating the same systematic mistake can produce very similar results. A suitable indicator, correctly conditioned equipment, and a careful endpoint decision are all necessary.
06Questions and solutions
Try each question before reading its solution. The questions move from routine endpoint calculations to situations where several experimental effects interact.
Question 1
A student titrates \(25.00\text{ mL}\) of an unknown monoprotic acid with \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
The initial burette reading is \(0.42\text{ mL}\). The correct endpoint occurs when the final burette reading reaches \(24.86\text{ mL}\).
The student continues adding sodium hydroxide until the final reading reaches \(24.96\text{ mL}\).
Assume a \(1:1\) mole ratio.
a) Calculate the correct titre.
b) Calculate the titre recorded by the student.
c) Calculate the correct acid concentration and the concentration obtained using the student’s recorded titre.
d) State the direction of the error.
Solution 1
The student’s calculated acid concentration is too high. The correct concentration is \(0.09776\text{ mol L}^{-1}\), while the overshot result is \(0.09816\text{ mol L}^{-1}\).
Step 1: Calculate the correct titre.
The volume delivered is the final reading minus the initial reading.
\[ \begin{aligned} V_T&=V_f-V_i\\ &=24.86-0.42\\ &=24.44\text{ mL} \end{aligned} \]
Step 2: Calculate the student’s recorded titre.
\[ \begin{aligned} V_T&=24.96-0.42\\ &=24.54\text{ mL} \end{aligned} \]
The student has recorded an additional \(0.10\text{ mL}\) of titrant.
Step 3: Calculate the correct acid concentration.
Using \(n=cV\):
\[ n(\ce{NaOH})=0.1000\times0.02444 \]
\[ n(\ce{NaOH})=0.002444\text{ mol} \]
The mole ratio is \(1:1\), so:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002444}{0.02500}\\ &=0.09776\text{ mol L}^{-1} \end{aligned} \]
Step 4: Calculate the concentration from the overshot titre.
\[ n(\ce{NaOH})=0.1000\times0.02454 \]
\[ n(\ce{NaOH})=0.002454\text{ mol} \]
Therefore:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002454}{0.02500}\\ &=0.09816\text{ mol L}^{-1} \end{aligned} \]
Step 5: Explain the direction of error.
The titre is too large because the student added sodium hydroxide after reaching the endpoint.
Since the calculated acid concentration is directly proportional to the titre, the calculated concentration is also too large.
The difference is \(0.00040\text{ mol L}^{-1}\), or approximately \(0.41\%\) of the correct value.
Question 2
A student has \(25.00\text{ mL}\) of a monoprotic acid with a concentration of \(0.0800\text{ mol L}^{-1}\). They titrate it with \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
Consider two experimental situations:
- Situation A: The conical flask contains \(10.0\text{ mL}\) of distilled water before the acid is transferred into it.
- Situation B: The volumetric pipette contains \(0.20\text{ mL}\) of residual distilled water. Assume this water occupies \(0.20\text{ mL}\) of the pipette’s calibrated volume, so only \(24.80\text{ mL}\) of the original acid solution is transferred.
For both situations:
a) Calculate the expected titre.
b) Explain why the two situations produce different results.
c) In Situation B, calculate the acid concentration that would be reported if the student incorrectly assumes that \(25.00\text{ mL}\) of undiluted acid was transferred.
Solution 2
Situation A produces the correct \(20.00\text{ mL}\) titre. Situation B produces a smaller \(19.84\text{ mL}\) titre, and the student reports an acid concentration that is too low.
Step 1: Calculate the expected titre in Situation A.
The acid contains:
\[ n(\text{acid})=0.0800\times0.02500 \]
\[ n(\text{acid})=0.002000\text{ mol} \]
The reaction has a \(1:1\) mole ratio, so \(0.002000\text{ mol}\) of sodium hydroxide is required.
\[ V_T=\frac{n}{c} \]
\[ V_T=\frac{0.002000}{0.1000} \]
\[ \boxed{V_T=20.00\text{ mL}} \]
The extra water in the flask does not change this result because the number of moles of acid remains \(0.002000\text{ mol}\).
Step 2: Calculate the expected titre in Situation B.
Only \(24.80\text{ mL}\) of the original acid solution enters the flask.
\[ n(\text{acid})=0.0800\times0.02480 \]
\[ n(\text{acid})=0.001984\text{ mol} \]
The required sodium hydroxide volume is:
\[ \begin{aligned} V_T&=\frac{0.001984}{0.1000}\\ &=0.01984\text{ L}\\ &=19.84\text{ mL} \end{aligned} \]
Step 3: Calculate the reported concentration in Situation B.
The student incorrectly assumes that the full \(25.00\text{ mL}\) contains the original acid concentration.
Using the measured titre:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.1000\times0.01984}{0.02500}\\ &=0.07936\text{ mol L}^{-1} \end{aligned} \]
Step 4: Explain the difference.
In Situation A, water is added after the pipette has transferred the correct number of moles of acid. The concentration decreases, but the amount of acid remains unchanged.
In Situation B, water is already inside the pipette. It takes up part of the calibrated volume, so fewer moles of acid are transferred in the first place.
The calculated concentration is therefore \(0.8\%\) too low.
The important distinction is not simply whether water is present. It is whether that water changes the number of moles transferred.
Question 3
A weak monoprotic acid is titrated with sodium hydroxide.
A titration curve for this particular reaction shows that the equivalence point occurs at \(22.40\text{ mL}\), at a pH of 8.7.
Two indicators are available:
| Indicator | Colour-change range |
|---|---|
| Indicator X | pH 3.5-4.5 |
| Indicator Y | pH 8.2-10.0 |
A student chooses indicator X. Even though they add sodium hydroxide drop by drop and swirl carefully, the observed endpoint occurs at \(21.80\text{ mL}\).
The sodium hydroxide concentration is \(0.1000\text{ mol L}^{-1}\), and the acid aliquot is \(25.00\text{ mL}\).
a) Which indicator is more appropriate?
b) Calculate the acid concentration using the actual equivalence point.
c) Calculate the concentration obtained using indicator X.
d) Explain why careful dropwise addition and concordant results cannot eliminate this error.
Solution 3
Indicator Y is the appropriate choice. Indicator X changes colour too early, producing a titre that is too small and an underestimated acid concentration.
Step 1: Select the appropriate indicator.
The equivalence point occurs at pH 8.7.
Indicator Y changes colour between pH 8.2 and 10.0, which overlaps the steep pH change around equivalence.
Indicator X changes colour between pH 3.5 and 4.5. This occurs well before the equivalence point on the given titration curve.
Therefore, indicator Y is more suitable.
Step 2: Calculate the correct acid concentration.
At equivalence:
\[ n(\ce{NaOH})=0.1000\times0.02240 \]
\[ n(\ce{NaOH})=0.002240\text{ mol} \]
The acid is monoprotic, so the mole ratio is \(1:1\).
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002240}{0.02500}\\ &=0.08960\text{ mol L}^{-1} \end{aligned} \]
Step 3: Calculate the concentration using indicator X.
The student stops at \(21.80\text{ mL}\).
\[ n(\ce{NaOH})=0.1000\times0.02180 \]
\[ n(\ce{NaOH})=0.002180\text{ mol} \]
Therefore:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002180}{0.02500}\\ &=0.08720\text{ mol L}^{-1} \end{aligned} \]
Step 4: Explain why adding slowly does not fix the error.
Adding sodium hydroxide drop by drop improves control over the observed colour change.
However, it cannot change the pH range at which the indicator changes colour.
Indicator X gives a precise observation of the wrong endpoint. The student stops before equivalence, so the titre is too small and the calculated acid concentration is approximately \(2.68\%\) too low.
The concordant results don’t solve this problem either. They show that the student can repeatedly reach a similar endpoint, not that the endpoint is chemically correct.
Question 4
A student titrates \(25.00\text{ mL}\) of a monoprotic acid using \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
The correct endpoint requires \(20.00\text{ mL}\) of sodium hydroxide to enter the conical flask.
However, two mistakes occur:
- An air bubble with a volume of \(0.25\text{ mL}\) is trapped in the burette tip at the initial reading. During the titration, \(0.25\text{ mL}\) of sodium hydroxide leaves the burette to fill the tip but does not enter the flask.
- After reaching the endpoint, the student adds another \(0.05\text{ mL}\) of sodium hydroxide before stopping.
Assume the student calculates the acid concentration using the full burette reading difference and the labelled sodium hydroxide concentration.
a) Calculate the titre recorded by the student.
b) Calculate the apparent acid concentration.
c) Calculate the percentage error relative to the correct acid concentration.
d) Explain why the air bubble and the overshoot both increase the recorded titre, even though they represent different experimental problems.
Solution 4
The recorded titre is \(20.30\text{ mL}\), giving an apparent acid concentration of \(0.08120\text{ mol L}^{-1}\), which is \(1.50\%\) too high.
Step 1: Identify the volume actually required for the reaction.
The correct endpoint requires:
\[ V_{\text{equivalence}}=20.00\text{ mL} \]
Step 2: Account for the air bubble.
The first \(0.25\text{ mL}\) of sodium hydroxide leaving the burette fills the space occupied by the air bubble.
Although this volume leaves the burette, it does not enter the conical flask.
The burette therefore records this volume as delivered even though it has not reacted with the acid.
Step 3: Account for the overshoot.
The student adds another \(0.05\text{ mL}\) after reaching equivalence.
This volume does enter the flask, but it is in excess of the amount required for the reaction.
The total recorded titre is therefore:
\[ \begin{aligned} V_T&=20.00+0.25+0.05\\ &=20.30\text{ mL} \end{aligned} \]
Step 4: Calculate the correct acid concentration.
The acid is monoprotic, so the mole ratio is \(1:1\).
\[ n(\ce{NaOH})=0.1000\times0.02000 \]
\[ n(\text{acid})=0.002000\text{ mol} \]
Therefore:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002000}{0.02500}\\ &=0.08000\text{ mol L}^{-1} \end{aligned} \]
Step 5: Calculate the apparent concentration.
The student uses the entire recorded titre:
\[ \begin{aligned} n(\ce{NaOH}) &=0.1000\times0.02030\\ &=0.002030\text{ mol} \end{aligned} \]
Therefore:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002030}{0.02500}\\ &=0.08120\text{ mol L}^{-1} \end{aligned} \]
Step 6: Calculate the percentage error.
\[ \begin{aligned} \%\text{ error} &=\frac{0.08120-0.08000}{0.08000} \times100\\ &=1.50\% \end{aligned} \]
Step 7: Explain the difference between the mistakes.
The air bubble creates a measurement error because some of the volume recorded as delivered never reaches the flask.
The overshoot is a genuine excess addition of titrant. It enters the flask after the reaction has reached equivalence.
Both increase the measured titre, but for different reasons.
If the air bubble had been removed before recording the initial burette reading, it would not have produced this particular error.
Question 5
This final question combines solution transfer, endpoint control, and the effect of apparently compensating errors.
A student is determining the concentration of an unknown monoprotic acid using \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
The following events occur:
- A \(25.00\text{ mL}\) volumetric pipette is rinsed with distilled water but not conditioned with the acid. Assume exactly \(0.20\text{ mL}\) of water remains inside the pipette and occupies part of its calibrated volume. Therefore, only \(24.80\text{ mL}\) of the original acid solution is transferred.
- The conical flask already contains \(10.0\text{ mL}\) of distilled water.
- The burette is correctly conditioned, its tip is completely filled, and it contains \(0.1000\text{ mol L}^{-1}\) sodium hydroxide.
- The student reaches the true endpoint after delivering \(19.84\text{ mL}\) of sodium hydroxide but adds another \(0.16\text{ mL}\) before stopping.
- The student records a titre of \(20.00\text{ mL}\) and calculates the acid concentration using the nominal \(25.00\text{ mL}\) pipette volume.
Answer the following:
a) Calculate the actual concentration of the original acid solution, accounting for the water remaining in the pipette.
b) Calculate the concentration reported by the student.
c) Explain why the two calculated concentrations are identical, despite the student making two experimental errors.
d) Would the errors still cancel if the student had added only \(0.10\text{ mL}\) after reaching the endpoint? Calculate the new reported concentration and explain your reasoning.
e) Does obtaining the correct numerical concentration in this experiment prove that the experimental procedure was reliable?
Solution 5
The actual acid concentration is \(0.08000\text{ mol L}^{-1}\). Remarkably, the student’s calculation also gives \(0.08000\text{ mol L}^{-1}\), because the pipette error and endpoint overshoot happen to compensate exactly.
This is a numerical coincidence, not evidence of a reliable method.
Step 1: Calculate the moles of acid actually transferred.
The pipette delivers \(25.00\text{ mL}\) of liquid, but only \(24.80\text{ mL}\) is the original acid solution.
At the true endpoint, the sodium hydroxide has delivered:
\[ n(\ce{NaOH})=0.1000\times0.01984 \]
\[ n(\ce{NaOH})=0.001984\text{ mol} \]
The acid is monoprotic, so the mole ratio is \(1:1\).
Therefore:
\[ n(\text{acid})=0.001984\text{ mol} \]
Step 2: Calculate the actual concentration of the original acid.
The volume of original acid solution transferred is \(24.80\text{ mL}\), not \(25.00\text{ mL}\).
\[ \begin{aligned} c(\text{acid}) &=\frac{0.001984}{0.02480}\\ &=0.08000\text{ mol L}^{-1} \end{aligned} \]
This is the actual concentration of the original acid solution.
Step 3: Calculate the student’s reported concentration.
The student ignores the residual water and assumes that \(25.00\text{ mL}\) of original acid was transferred.
They also use the overshot titre of \(20.00\text{ mL}\).
\[ n(\ce{NaOH})=0.1000\times0.02000 \]
\[ n(\ce{NaOH})=0.002000\text{ mol} \]
The student calculates:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.002000}{0.02500}\\ &=0.08000\text{ mol L}^{-1} \end{aligned} \]
The reported concentration is identical to the actual concentration.
Step 4: Explain why the errors cancel.
There are two competing effects.
The unconditioned pipette transfers fewer moles of acid than intended. This decreases the titre required to reach equivalence.
The endpoint overshoot increases the measured titre because additional sodium hydroxide is delivered after equivalence.
In this particular example, the two errors have exactly the right magnitudes to cancel in the final concentration calculation.
We can demonstrate this by comparing the volume ratios:
\[ \frac{24.80}{25.00}\times \frac{20.00}{19.84}=1.000 \]
The first ratio represents the reduction in the volume of original acid transferred.
The second represents the increase in the recorded titre.
Their product is exactly one, so the two errors cancel in the final calculation.
Step 5: Investigate what happens with a smaller overshoot.
Suppose the student adds only \(0.10\text{ mL}\) after reaching the true endpoint.
The recorded titre is now:
\[ V_T=19.84+0.10=19.94\text{ mL} \]
The student still assumes that \(25.00\text{ mL}\) of original acid was transferred.
Their reported concentration becomes:
\[ \begin{aligned} c(\text{acid}) &=\frac{0.1000\times0.01994}{0.02500}\\ &=0.07976\text{ mol L}^{-1} \end{aligned} \]
Compared with the actual concentration:
\[ \begin{aligned} \%\text{ error} &=\frac{0.07976-0.08000}{0.08000} \times100\\ &=-0.30\% \end{aligned} \]
The reported concentration is now \(0.30\%\) too low.
The errors no longer cancel because the additional titrant volume is different.
Step 6: Evaluate the reliability of the experiment.
Obtaining the correct numerical answer does not prove that the method was reliable.
The result was correct only because two independent mistakes happened to offset one another.
A different residual water volume or endpoint overshoot would produce a different result. Repeating the experiment does not guarantee that the same compensation will occur again.
There is also no reason to assume that two experimental errors will cancel simply because one increases the titre and the other decreases it.
The correct procedure is to condition the pipette, transfer the intended aliquot, and stop at the first persistent endpoint colour.
The key lesson is that a correct-looking answer is not necessarily evidence of an accurate experiment.
07Where to go next
Once you can recognise the endpoint and control the final drops, the next task is deciding whether repeated titres are sufficiently close to use in your final calculation.
That’s where concordant titres and the mean titre come in. Remember, averaging improves the handling of random variation, but it cannot automatically correct a systematic endpoint error shared by every trial.
For your next titration calculation, keep three decisions separate:
- Preparation: Were the correct concentrations and amounts of solution transferred?
- Endpoint: Did you stop at the first appropriate persistent colour change?
- Measurement: Did you record and calculate the volume actually delivered?
Getting all three right is what makes a titration result trustworthy.