Atomic Clocks and Hyperfine Transitions

Discover how caesium-133 hyperfine transitions provide the frequency reference for atomic clocks. Explore microwave resonance, feedback systems, Ramsey interrogation, and the physical effects that limit clock accuracy.

A quartz clock can lose or gain a little time because its electronic oscillator changes with temperature, age, and other conditions. An atomic clock has a different way to check its frequency: it uses a transition between two precisely defined energy states in an atom. If the oscillator drifts away from the transition frequency, the clock detects the error and corrects it.

This is the central idea behind an atomic clock. The atom provides a highly reproducible frequency reference, while an electronic feedback system continually adjusts the clock’s oscillator to match it.

Atomic clocks and hyperfine transitions are an extension beyond the required HSC Physics syllabus. The Year 12 Matter, energy and the cosmos material provides a useful starting point, particularly the study of nuclear energy and fission, but you are not expected to know how atomic clocks operate for the HSC examination.

01From nuclear fission to atomic energy levels

Before looking at atomic clocks, it is worth revisiting what happens during nuclear fission. It gives us a useful foundation for understanding how changes in the internal structure of matter can involve energy.

Nuclear fission: energy released from the nucleus

Imagine a neutron entering the nucleus of a uranium-235 atom. The nucleus can absorb the neutron, becoming an unstable uranium-236 nucleus. It may then split into two smaller nuclei, releasing additional neutrons and energy.

One possible fission reaction is:

\[ {}^{235}_{92}\mathrm{U}+{}^{1}_{0}\mathrm{n} \rightarrow {}^{141}_{56}\mathrm{Ba} +{}^{92}_{36}\mathrm{Kr} +3{}^{1}_{0}\mathrm{n} +\text{energy} \]

This is one possible outcome, not the only possible combination of fission products.

A left-to-right schematic shows a neutron entering uranium-235, unstable uranium-236 splitting into barium-141 and krypton-92, three outgoing neutrons, and separately depicted released energy.
One possible fission event: uranium-235 absorbs a neutron, then unstable uranium-236 splits into barium-141, krypton-92, three neutrons and released energy.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The energy comes from the difference in total mass between the initial particles and the final products. The products have slightly less total mass than the original uranium nucleus and incoming neutron. This difference is called the mass defect.

Einstein’s mass-energy relationship explains the energy released:

\[ E=\Delta mc^2 \]

Here, \(E\) is the released energy in joules, \(\Delta m\) is the mass defect in kilograms, and \(c\) is the speed of light in a vacuum.

The outgoing neutrons can trigger further fission events. If enough neutrons continue producing further fissions, a chain reaction develops. In a nuclear reactor, the chain reaction is controlled so that energy is released at a manageable rate.

Why this matters for atomic clocks

Nuclear fission and atomic clocks both involve energy differences, but they use fundamentally different physical processes.

  • Nuclear fission changes the nucleus itself. Nuclear energy levels and the binding of protons and neutrons determine the energy released.
  • An atomic clock uses a much smaller energy difference associated with the interaction between an atom’s electrons and its nucleus. The nucleus does not split, and the atom does not undergo a nuclear reaction.

The distinction is important. An atomic clock does not use radioactive decay or nuclear fission to measure time. It uses a reproducible frequency associated with a particular atomic transition.

02What makes an atomic transition useful as a clock?

Think about a playground swing. If you push it at random intervals, it moves, but your pushes do not provide a reliable way to measure its natural rhythm. If you push it at the right frequency, however, each push reinforces the swing’s motion.

Atoms have a different, quantum-mechanical version of a preferred frequency. They can absorb electromagnetic radiation when its frequency matches the energy difference between two allowed energy states.

The relationship is:

\[ \Delta E=hf \]

where:

  • \(\Delta E\) is the energy difference between the two states, in joules
  • \(h\) is Planck’s constant, \(6.62607015\times10^{-34}\ \mathrm{J\,s}\)
  • \(f\) is the frequency of the electromagnetic radiation, in hertz (Hz).

A larger energy difference requires higher-frequency radiation. A smaller energy difference requires lower-frequency radiation.

This is the same underlying relationship used when studying photon absorption and emission in atomic transitions. If you need to revisit that foundation, see Photon energy and atomic transitions: HSC Physics guide.

But not every atomic transition is equally useful for a clock. We want a transition whose frequency can be measured repeatedly with extremely high precision, and whose value is relatively insensitive to small disturbances.

One particularly important example is a hyperfine transition in caesium-133.

03Hyperfine transitions: a tiny difference with a big job

To understand hyperfine splitting, start with the structure of an atom.

An atom has a positively charged nucleus surrounded by electrons. Both the electrons and the nucleus have angular momentum, and some of these forms of angular momentum produce magnetic moments.

A magnetic moment describes how a particle or system responds to a magnetic field. You can picture it loosely as a tiny magnet, although this picture does not capture the full quantum behaviour.

The electron’s magnetic moment interacts with the magnetic moment of the nucleus. This magnetic interaction slightly changes the atom’s energy.

The result is a splitting of an atomic energy level into two or more closely spaced levels. This is called hyperfine splitting.

Why does caesium-133 have two relevant ground-state levels?

The caesium-133 nucleus has nuclear spin \(I=7/2\). Its outermost electron has total angular momentum \(J=1/2\) in the ground state.

These angular momenta combine to give a total atomic angular momentum, represented by \(F\).

For this particular atom, the two possible values are:

\[ F=I+J=4 \]

and

\[ F=I-J=3 \]

The two configurations have slightly different energies because the relative alignment of the electron and nuclear angular momenta changes their magnetic interaction.

The lower-energy state has \(F=3\), while the higher-energy state has \(F=4\).

A transition between these two states is a hyperfine transition.

The key point is that the energy difference is extremely small compared with the energy differences associated with many ordinary electronic transitions. Consequently, the radiation required to produce this transition is in the microwave region of the electromagnetic spectrum.

The frequency that defines the second

The ground-state hyperfine transition of an unperturbed caesium-133 atom has a frequency of exactly:

\[ \boxed{f_{\mathrm{Cs}}=9\,192\,631\,770\ \mathrm{Hz}} \]

That is approximately \(9.19\) billion cycles per second, or \(9.19\ \mathrm{GHz}\).

The International System of Units (SI) defines one second by fixing this caesium frequency to that exact numerical value.

In other words, one second corresponds to the duration of exactly 9,192,631,770 periods of radiation associated with this transition.

This is not simply a convenient measurement made by a laboratory. It is part of the formal definition of the SI second.

The word unperturbed matters. The reference frequency describes an idealised caesium atom free from external influences that would shift its transition frequency. Real clocks must account for such influences when they measure the transition.

Notice something important: the atom is not acting like a tiny mechanical clock whose parts physically swing back and forth 9.19 billion times each second. The transition provides a precise frequency reference. The clock’s electronic oscillator generates the microwave signal, and the atom tells the system whether that signal is at the correct frequency.

04How does the clock actually keep time?

Knowing the correct atomic frequency is only half the problem. We still need a way to produce a signal at that frequency and keep it there.

Consider a microwave oscillator that generates a signal close to 9.192631770 GHz. It might initially be slightly too fast or too slow.

If we could compare this signal with the atomic transition, we could detect the difference and correct the oscillator.

This is the job of a feedback system.

Step 1: Prepare the atoms

A sample of caesium atoms is prepared in a suitable state and allowed to interact with microwave radiation.

In a caesium atomic clock, the atoms are exposed to microwaves close to the hyperfine transition frequency.

The microwaves can cause atoms to move between the \(F=3\) and \(F=4\) states.

Step 2: Interrogate the atoms

The microwave frequency is varied around the expected atomic resonance.

If the frequency is close to the transition frequency, the atoms respond strongly. If it is further away, the response changes.

The clock measures this response by detecting how many atoms occupy a particular state after the interaction.

Step 3: Measure the error

A single measurement at the atomic resonance tells us that the oscillator is close to the correct frequency, but it does not necessarily tell us which direction to adjust it.

To solve this, the clock can compare measurements made at frequencies slightly above and below the expected resonance.

Suppose the two measurements give different transition signals. Their difference tells the control system whether the oscillator needs to increase or decrease its frequency.

This difference is called an error signal.

Step 4: Apply feedback

The error signal is sent to an electronic controller, which adjusts the microwave oscillator.

If the oscillator is too high, the controller lowers its frequency. If it is too low, the controller raises it.

The process repeats continuously.

The oscillator is therefore locked to the atomic transition.

This is called a closed-loop feedback system. Its defining feature is that the output is measured and used to correct the input-producing system.

The atomic transition provides the reference. The oscillator provides the repeating signal. The feedback system keeps the two aligned.

Reading the resonance: why the controller needs two measurements

The atomic response can be plotted against microwave frequency. The result is a resonance curve, with the strongest response occurring close to the natural transition frequency.

There is a subtle problem here.

Suppose the oscillator is slightly too fast. A measurement at just one frequency might show that the atoms respond strongly, but how does the controller know whether to increase or decrease the frequency?

It needs to know which side of the resonance it is on.

A useful technique is to measure the response at two frequencies, one slightly above the estimated resonance and one slightly below it.

  • If the lower-frequency measurement produces a stronger response, the oscillator’s central frequency is too high.
  • If the higher-frequency measurement produces a stronger response, the oscillator’s central frequency is too low.
  • If both measurements produce equal responses, the oscillator is centred on the resonance, assuming the two probes are placed symmetrically around the centre.

The difference between the two measurements provides a signed error signal. Its sign tells the controller which direction to adjust the oscillator.

This is more useful than simply finding the largest atomic response. It gives the controller information about the direction of the error.

Why do some atomic clocks use a fountain?

A basic atomic beam clock sends atoms through microwave interaction regions. The atoms travel quickly, so the available interaction time is relatively short.

A more precise design uses a caesium fountain.

First, laser beams slow a cloud of caesium atoms. The atoms are then launched upwards inside a vacuum chamber. Gravity slows their upward motion, brings them momentarily to rest, and accelerates them downwards.

During this journey, the atoms pass through a microwave cavity twice: once on the way up and once on the way down.

The two microwave interactions form an example of Ramsey interrogation, a method that makes it possible to measure the transition frequency very precisely.

During the first interaction, the microwave pulse places atoms into a quantum state that combines the two hyperfine energy states. This is called a superposition.

While the atoms travel between interactions, the relative quantum phase of the two states evolves. The microwave signal provides the reference against which this evolution can be compared.

The second interaction converts the accumulated phase difference into a measurable difference in the final populations of the two states.

The detector measures those populations, allowing the clock to determine how closely the microwave oscillator matches the atomic transition.

Why bother sending the atoms on such a long journey?

The longer the time between the two microwave interactions, the more sensitive the measurement becomes to a small difference between the oscillator frequency and the atomic resonance.

In simplified terms, the characteristic width of the central Ramsey resonance varies approximately as:

\[ \Delta f\sim\frac{1}{T} \]

Here, \(\Delta f\) is the characteristic frequency width in hertz, and \(T\) is the time between the two microwave interactions in seconds.

A longer interrogation time produces a narrower resonance. This makes small frequency differences easier to detect.

The relationship is an approximate scaling rule, not an exact linewidth formula for every clock design.

The advantage of the fountain is therefore not that it changes the natural frequency of caesium. It gives the clock a more sensitive way to measure that same frequency.

05What can make an atomic clock inaccurate?

At this point, it might seem that the problem is solved. Caesium atoms have a natural transition frequency, the oscillator is locked to it, and the clock counts the microwave cycles.

But there is one more complication.

Real atoms are not completely isolated. Their surroundings can slightly change the transition frequency.

Remember that the SI definition refers to an unperturbed caesium-133 atom. An actual clock must work out how closely its measured frequency represents that ideal reference.

Magnetic fields and hyperfine energy levels

The electron and nuclear magnetic moments interact with an external magnetic field. This changes the energies of the hyperfine sublevels through an effect called the Zeeman effect.

Each hyperfine level can split into several magnetic sublevels, labelled by the quantum number \(m_F\).

For a caesium-133 primary frequency standard, the clock transition is commonly chosen between:

\[ |F=3,m_F=0\rangle \]

and

\[ |F=4,m_F=0\rangle \]

Here, \(m_F\) describes the component of the total angular momentum along the chosen magnetic-field direction.

The choice of \(m_F=0\) is important. This particular transition has no first-order Zeeman frequency shift for a weak magnetic field.

However, it is not completely immune to magnetic fields. A smaller second-order shift remains, so the magnetic field must still be controlled and measured.

Other influences include:

  • Thermal radiation from the surrounding apparatus, which can shift the atomic energy levels.
  • Collisions between atoms, which can alter their transition frequencies.
  • Motion of the atoms, which can introduce Doppler-related effects.
  • Imperfections in the microwave field, including unwanted interactions outside the intended interrogation region.

These effects are not reasons to abandon atomic clocks. They are quantities that precision clock designers measure, control, and correct for.

Stability is not the same as accuracy

Two terms are worth separating.

Frequency stability describes how much the measured frequency fluctuates over time. A highly stable clock produces very consistent measurements.

Frequency accuracy describes how closely the clock’s realised frequency matches the ideal reference frequency.

A clock can be extremely stable but inaccurate.

Imagine a clock whose microwave oscillator is consistently locked to a transition that has been shifted by a small external magnetic field. Its feedback system might report almost zero error on every measurement.

That does not mean it is reproducing the unperturbed caesium frequency.

The feedback system has done its job perfectly: it has matched the oscillator to the atomic transition it can actually measure. The problem is that the measured transition has been shifted.

This is a fundamental limitation of feedback. It can correct the oscillator’s frequency, but it cannot automatically distinguish a genuine oscillator error from a shift in the reference itself.

A precision clock therefore needs both a good feedback system and careful control of the environment.

06Worked examples

Worked example: calculate the energy of a caesium microwave photon

A microwave photon has the frequency of the caesium-133 ground-state hyperfine transition, \(9.192631770\times10^9\ \mathrm{Hz}\). Calculate its energy.

Step 1

\[ E=hf \]

Here, \(E\) is the photon energy, \(h\) is Planck’s constant, and \(f\) is the photon frequency.

Step 2

\[ \begin{aligned} E&=(6.62607015\times10^{-34})\\ &\quad\times(9.192631770\times10^9) \end{aligned} \]

Step 3

\[ E=6.0911\times10^{-24}\ \mathrm{J} \]

Answer: The photon carries approximately \(6.09\times10^{-24}\ \mathrm{J}\) of energy.

This is the energy required to move a caesium-133 atom between the two relevant hyperfine states through absorption of a photon at the transition frequency.

The energy is tiny, which is why the transition occurs using microwave rather than visible-light radiation.

Worked example: how much time does a 1 Hz frequency error lose?

A caesium atomic clock should operate at \(9,192,631,770\ \mathrm{Hz}\). Suppose its microwave oscillator is actually running at \(9,192,631,771\ \mathrm{Hz}\), an error of \(+1\ \mathrm{Hz}\).

Assuming the error remains constant, estimate how far the clock will gain or lose after 24 hours.

Step 1

The fractional frequency error is the frequency difference divided by the reference frequency:

\[ \varepsilon=\frac{\Delta f}{f_0} \]

Here, \(\Delta f\) is the frequency error, \(f_0\) is the reference frequency, and \(\varepsilon\) is the dimensionless fractional error.

Substituting:

\[ \varepsilon= \frac{1}{9.192631770\times10^9} \]

\[ \varepsilon\approx1.088\times10^{-10} \]

Step 2

\[ t=24\times60\times60 \]

\[ t=86,400\ \mathrm{s} \]

Step 3

For a small, constant fractional frequency error:

\[ \Delta t\approx\varepsilon t \]

Substituting:

\[ \begin{aligned} \Delta t&=(1.088\times10^{-10})(86,400)\\ &\approx9.40\times10^{-6}\ \mathrm{s} \end{aligned} \]

Answer: The clock gains approximately \(9.4\ \mathrm{\mu s}\) over 24 hours.

The oscillator is running too quickly, so it counts the required number of cycles slightly sooner than it should.

This example shows why atomic clock feedback must detect incredibly small frequency differences. Even a 1 Hz error at a frequency of more than 9 billion hertz produces a measurable timing error over a day.

The worked example uses a positive frequency offset, so the clock gains time. An oscillator running 1 Hz below the reference would instead make the clock lose approximately the same amount over 24 hours.

07Questions and solutions

Question 1

The ground-state hyperfine transition frequency of caesium-133 is \(9,192,631,770\ \mathrm{Hz}\).

Calculate the period of one microwave cycle. State how many cycles of the corresponding radiation define one SI second.

Solution 1

The period is approximately \(1.088\times10^{-10}\ \mathrm{s}\), and exactly 9,192,631,770 cycles define one SI second.

Frequency is the number of cycles completed per second, so the period is the reciprocal of frequency.

Step 1: Identify the relationship.

\[ T=\frac{1}{f} \]

Here, \(T\) is the period in seconds and \(f\) is the frequency in hertz.

Step 2: Substitute the frequency.

\[ T=\frac{1}{9.192631770\times10^9} \]

\[ T=1.0878\times10^{-10}\ \mathrm{s} \]

Step 3: Interpret the result.

Each microwave cycle takes approximately \(0.109\) nanoseconds.

The SI definition uses the duration of 9,192,631,770 of these periods to establish one second.

The important distinction is that the clock counts cycles of the microwave radiation. It does not need to wait for an individual atom to complete billions of separate transitions.

Question 2

A caesium atomic clock has an unperturbed transition frequency \(f_0\).

Its microwave oscillator is currently set to:

\[ f_c=f_0+0.40\ \mathrm{Hz} \]

The controller tests two frequencies:

  • Lower probe: \(f_c-1.0\ \mathrm{Hz}\)
  • Higher probe: \(f_c+1.0\ \mathrm{Hz}\)

The detector records the following percentages of atoms in the higher \(F=4\) state:

ProbePercentage in higher state
Lower frequency52%
Higher frequency44%

Assume the two probe frequencies lie on opposite slopes of a symmetric central Ramsey resonance peak.

(a) Is the oscillator running too fast or too slowly?

(b) Which direction should the feedback controller adjust its frequency?

(c) Can the exact frequency correction be calculated from these two percentages alone? Explain.

Solution 2

The oscillator is running too fast, so the controller should decrease its frequency. The two percentages identify the direction of the error, but they are insufficient to calculate its exact magnitude.

Step 1: Calculate the two probe frequencies relative to the reference.

The lower probe is:

\[ f_{\mathrm{low}}=f_0+0.40-1.0 \]

\[ f_{\mathrm{low}}=f_0-0.60\ \mathrm{Hz} \]

The higher probe is:

\[ f_{\mathrm{high}}=f_0+0.40+1.0 \]

\[ f_{\mathrm{high}}=f_0+1.40\ \mathrm{Hz} \]

Step 2: Compare their distances from resonance.

The lower probe is \(0.60\ \mathrm{Hz}\) below the reference.

The higher probe is \(1.40\ \mathrm{Hz}\) above the reference.

Therefore, the lower probe is closer to resonance.

Step 3: Interpret the detector readings.

The lower probe produces a 52% transition response, while the higher probe produces only 44%.

This is consistent with the lower probe being closer to the resonance peak.

The oscillator’s central frequency must therefore be above the true resonance frequency.

Step 4: Apply the feedback correction.

The controller should decrease the oscillator frequency.

It uses the difference between the two measurements to construct a signed error signal. Repeated adjustments bring the oscillator towards the centre of the resonance.

Step 5: Consider the information available.

The difference between the measured percentages is eight percentage points.

However, the relationship between frequency offset and transition probability is not necessarily linear. Without knowing the calibrated resonance curve, we cannot convert that difference directly into an exact frequency correction.

This is why a feedback system needs a calibrated response, rather than simply treating every difference in detector readings as a fixed frequency error.

Question 3

A traditional caesium atomic beam clock and a caesium fountain clock use the same hyperfine transition.

The approximate time between the two microwave interactions is:

  • Beam clock: \(5.0\ \mathrm{ms}\)
  • Fountain clock: \(0.50\ \mathrm{s}\)

Use the approximate relationship

\[ \Delta f\sim\frac{1}{T} \]

to estimate the characteristic resonance width for each clock.

(a) Calculate both characteristic widths.

(b) How many times narrower is the fountain clock’s resonance?

(c) Explain why the fountain design improves frequency measurement. Does a narrower resonance automatically guarantee greater absolute accuracy?

Solution 3

The beam clock has an approximate characteristic resonance width of \(200\ \mathrm{Hz}\), while the fountain clock has a width of \(2.0\ \mathrm{Hz}\). The fountain resonance is approximately 100 times narrower.

Step 1: Calculate the beam clock’s characteristic width.

Convert milliseconds into seconds:

\[ T_{\mathrm{beam}}=5.0\times10^{-3}\ \mathrm{s} \]

Using the approximate relationship:

\[ \Delta f\sim\frac{1}{T} \]

\[ \Delta f_{\mathrm{beam}} \sim\frac{1}{0.0050} \]

\[ \Delta f_{\mathrm{beam}}\sim200\ \mathrm{Hz} \]

Step 2: Calculate the fountain clock’s characteristic width.

\[ \Delta f_{\mathrm{fountain}} \sim\frac{1}{0.50} \]

\[ \Delta f_{\mathrm{fountain}}\sim2.0\ \mathrm{Hz} \]

Step 3: Compare the widths.

\[ \text{Width ratio}=\frac{200}{2.0} \]

\[ \text{Width ratio}=100 \]

The fountain’s resonance is approximately 100 times narrower.

Step 4: Explain the physical reason.

The laser-cooled atoms in the fountain move much more slowly than the atoms in a traditional beam clock.

This gives them a longer period between microwave interactions. Their quantum phase has more time to evolve, making the Ramsey measurement more sensitive to small differences between the oscillator and atomic frequencies.

A narrow resonance allows the feedback system to detect smaller frequency offsets.

Step 5: Consider accuracy.

A narrower resonance improves the ability to measure frequency, but it does not automatically remove systematic errors.

For example, a magnetic field could shift the resonance even if the clock measures its position with extremely high precision.

The fountain might therefore have a more sensitive measurement but still require corrections for environmental effects.

The distinction is between measuring a frequency precisely and knowing that the measured frequency is the correct reference.

Question 4

A caesium atomic clock uses the transition between the \(F=3,m_F=0\) and \(F=4,m_F=0\) states.

Despite magnetic shielding, a residual magnetic field causes the measured transition frequency to shift upwards by \(0.30\ \mathrm{Hz}\).

The feedback system adjusts the microwave oscillator until its error signal becomes zero.

(a) Explain how the feedback system can report zero error even though the clock is not operating at the unperturbed caesium frequency.

(b) Calculate the fractional frequency shift.

(c) Estimate how much time the clock gains over 24 hours if it remains locked to this shifted frequency.

(d) Explain why choosing the \(m_F=0\) transition reduces magnetic-field sensitivity but does not eliminate the problem completely.

Solution 4

The clock can report zero feedback error because its oscillator has locked to the magnetically shifted atomic resonance, rather than the unperturbed reference frequency. It gains approximately \(2.82\ \mathrm{\mu s}\) per day.

Step 1: Explain the zero error signal.

The feedback system compares the oscillator frequency with the transition frequency that the atoms actually exhibit.

The residual magnetic field has shifted that transition upwards by \(0.30\ \mathrm{Hz}\).

The oscillator adjusts until it matches this shifted resonance.

The difference between the oscillator and the measured atomic resonance is therefore approximately zero.

However, the measured resonance is not equal to the unperturbed reference frequency.

The feedback system cannot automatically distinguish an oscillator error from a shift in the atomic energy levels.

Step 2: Calculate the fractional frequency shift.

The fractional frequency shift is:

\[ \varepsilon=\frac{\Delta f}{f_0} \]

Substitute:

\[ \varepsilon= \frac{0.30}{9.192631770\times10^9} \]

\[ \varepsilon\approx3.26\times10^{-11} \]

Step 3: Convert 24 hours into seconds.

\[ t=86,400\ \mathrm{s} \]

Step 4: Calculate the accumulated timing error.

\[ \Delta t\approx\varepsilon t \]

\[ \begin{aligned} \Delta t&=(3.26\times10^{-11})(86,400)\\ &\approx2.82\times10^{-6}\ \mathrm{s} \end{aligned} \]

Therefore:

\[ \Delta t\approx2.82\ \mathrm{\mu s} \]

The clock gains approximately \(2.82\) microseconds per day because its frequency is too high.

Step 5: Explain the role of the \(m_F=0\) transition.

The \(m_F=0\) to \(m_F=0\) transition is insensitive to the first-order Zeeman shift in a weak magnetic field.

This makes it much less sensitive to small magnetic-field changes than transitions involving other magnetic sublevels.

However, second-order Zeeman effects remain. These produce a smaller frequency shift that must still be measured and corrected.

Magnetic shielding and careful field measurements are therefore still necessary.

The key lesson is that a successful feedback lock does not automatically establish an accurate clock.

Question 5

Two laboratories construct different caesium fountain clocks. Both use the same unperturbed ground-state hyperfine transition of caesium-133.

Their measured characteristics are:

PropertyClock AClock B
Ramsey interrogation time0.50 s0.10 s
Statistical frequency uncertainty after one day0.040 Hz0.100 Hz
Residual systematic frequency offset+0.30 Hz+0.020 Hz

Both feedback systems report zero error because their oscillators are locked to their respective measured atomic resonances.

Assume:

  • The approximate resonance-width relationship is \(\Delta f\sim1/T\).
  • Statistical frequency uncertainty decreases in proportion to \(1/\sqrt{D}\), where \(D\) is the number of days of measurement.
  • The residual systematic offsets remain constant and are not corrected.
  • Both clocks use the same ideal reference frequency, \(9,192,631,770\ \mathrm{Hz}\).

(a) Which clock has the narrower resonance? Calculate the approximate widths and compare them.

(b) Calculate the statistical frequency uncertainty of each clock after 100 days.

(c) Which clock provides the closer estimate of the unperturbed caesium frequency after 100 days?

(d) Explain why Clock A’s narrower resonance, lower statistical uncertainty, and zero feedback error do not necessarily make it the more accurate clock.

(e) What would need to happen for Clock A to become the better frequency standard?

Solution 5

Clock A has the narrower resonance and lower statistical uncertainty, but Clock B provides the closer estimate of the unperturbed caesium frequency. Clock A’s remaining systematic shift is too large to be removed simply by collecting more measurements.

This problem combines three different ideas: resonance width, statistical uncertainty, and systematic frequency shifts.

Step 1: Compare the resonance widths.

For Clock A:

\[ \Delta f_A\sim\frac{1}{0.50} \]

\[ \Delta f_A\sim2.0\ \mathrm{Hz} \]

For Clock B:

\[ \Delta f_B\sim\frac{1}{0.10} \]

\[ \Delta f_B\sim10\ \mathrm{Hz} \]

Therefore, Clock A has a resonance approximately five times narrower.

This gives Clock A a more sensitive frequency discriminator.

Step 2: Calculate the statistical uncertainties after 100 days.

The statistical uncertainty decreases as:

\[ \sigma_D=\frac{\sigma_1}{\sqrt{D}} \]

Here, \(\sigma_D\) is the statistical uncertainty after \(D\) days, and \(\sigma_1\) is the uncertainty after one day.

For 100 days:

\[ \sqrt{100}=10 \]

Clock A:

\[ \sigma_A=\frac{0.040}{10} \]

\[ \sigma_A=0.0040\ \mathrm{Hz} \]

Clock B:

\[ \sigma_B=\frac{0.100}{10} \]

\[ \sigma_B=0.010\ \mathrm{Hz} \]

Clock A has the smaller statistical uncertainty.

Its measurements are more tightly clustered around their own mean frequency.

Step 3: Compare the systematic offsets.

Clock A has a residual systematic offset of:

\[ +0.30\ \mathrm{Hz} \]

Clock B has a residual systematic offset of:

\[ +0.020\ \mathrm{Hz} \]

Clock A is therefore biased 15 times further from the ideal frequency than Clock B.

After 100 days, the random statistical uncertainties have decreased, but the systematic offsets remain unchanged.

The expected mean frequency of Clock A is still \(0.30\ \mathrm{Hz}\) too high.

The expected mean frequency of Clock B is only \(0.020\ \mathrm{Hz}\) too high.

Step 4: Decide which clock is more accurate.

Clock B is closer to the unperturbed caesium frequency.

This is the important result.

Clock A has a narrower resonance and lower statistical uncertainty. However, these advantages do not compensate for its much larger remaining systematic offset.

The tempting conclusion is that Clock A must be better because it measures the transition more precisely.

The constraint that changes the answer is that its reference frequency is still shifted.

Collecting more data reduces random uncertainty, not a constant systematic bias.

Step 5: Determine how Clock A could become the better standard.

Clock A would need its systematic shift to be independently characterised and corrected.

For example, scientists could investigate the magnetic field, thermal radiation, and atomic collisions affecting its transition frequency.

If the remaining uncertainty in the correction became sufficiently small, Clock A’s narrower resonance and lower statistical uncertainty could make it the better standard.

This is why precision atomic clocks require more than a good oscillator and a sensitive detector. They also require careful evaluation of every physical effect that can shift the atomic reference.

08Where atomic clocks lead next

An atomic clock is not simply an electronic device that counts very quickly.

It is a measurement system built around a reproducible quantum transition. The atom supplies the reference frequency, the microwave oscillator generates the signal, the detector measures the atomic response, and the feedback system keeps the oscillator aligned with that response.

The hyperfine transition of caesium-133 is especially important because its unperturbed frequency defines the SI second.

Understanding this mechanism also gives you a useful starting point for a much bigger question: if two identical atomic clocks are placed in different physical conditions, will they continue to measure time at the same rate?

The answer connects atomic physics with Einstein’s theories of relativity. Motion and gravitational potential can affect the rate at which clocks measure time, even when both clocks use the same atomic transition.

Continue with Atomic-Clock Tests of Relativity: HSC Physics Explained to explore how precision atomic clocks provide experimental tests of relativity.

09Sources and further reading

The scientific explanations in this article draw on the following institutional and scientific references.