How to Find Average Power from a Changing Energy Graph
Learn how to calculate average power from curved and changing energy-versus-time graphs using secant gradients. Includes worked HSC Physics examples covering energy transfers, sign conventions, efficiency, and common exam mistakes.
A battery’s energy store decreases from 30 kJ to 18 kJ over 6 seconds. However, its energy-versus-time graph is curved: the energy decreases quickly at first, then more slowly.
Did the battery deliver the same power throughout the 6 seconds?
No. Its rate of energy transfer changed. But we can still calculate its average power over the complete interval using the change in energy divided by the elapsed time.
\[
P_{\text{avg}}=\frac{30-18}{6}
=2.0\text{ kW}
\]
The battery delivered an average of 2.0 kJ of energy each second. This does not mean it delivered exactly 2.0 kW at every instant.
This is the key to answering questions about changing energy graphs: **average power is the gradient between two selected points, not the gradient at every point on the curve.**
[IMAGE: An annotated energy-stored-versus-time graph showing a smoothly decreasing curved line. Mark the initial point at 0 s and 30 kJ and the final point at 6 s and 18 kJ. Draw a straight secant joining these endpoints, labelled average power. Add a steeper tangent near the beginning and a shallower tangent near the end to show that instantaneous power changes. Include clearly labelled time and stored-energy axes.]
## 1. Finding average power from an energy graph
Start by identifying exactly what the graph measures.
An energy-versus-time graph has:
- Time, \(t\), on the horizontal axis, measured in seconds (s).
- Energy, \(E\), on the vertical axis, measured in joules (J), kilojoules (kJ), or another stated energy unit.
The gradient tells you how quickly the energy changes.
For two points on the graph, the average rate of energy change is
\[
\boxed{P_{\text{avg}}=\frac{\Delta E}{\Delta t}}
\]
where:
- \(P_{\text{avg}}\) is average power, measured in watts (W).
- \(\Delta E=E_2-E_1\) is the change in energy.
- \(\Delta t=t_2-t_1\) is the elapsed time.
Remember that \(1\text{ W}=1\text{ J s}^{-1}\).
If the energy axis is in kilojoules and the time axis is in seconds, your gradient will be in kilojoules per second. Conveniently,
\[
1\text{ kJ s}^{-1}=1\text{ kW}
\]
You do not need to convert kilojoules into joules if you keep the final answer in kilowatts.
### The important distinction: secant versus tangent
There are two different gradients you might calculate from a curved energy graph.
**Average power:** Use the gradient of the straight line joining the two points that define your time interval. This line is called a secant.
**Instantaneous power:** Use the gradient of a tangent to the curve at one particular point. This describes the power at that instant.
[IMAGE: Two side-by-side energy-versus-time graphs. On the first, show a curved energy line with two selected points joined by a straight secant, labelled average power over the interval. On the second, show a tangent touching a curved energy line at one point, labelled instantaneous power at that time. Make the difference between the two gradients visually clear.]
For HSC questions asking for average power between two times, use the secant gradient. Do not calculate the gradient at the beginning or end unless the question specifically asks for instantaneous power.
### What if the energy graph slopes downwards?
This is where students often lose a sign.
Suppose the graph shows the energy stored in a battery. As the battery supplies energy to an external circuit, its stored energy decreases.
Its graph therefore has a negative gradient.
Using the mathematical sign convention,
\[
P_{\text{store}}=\frac{\Delta E_{\text{store}}}{\Delta t}
\]
gives a negative result.
However, if the question asks for the average power delivered by the battery, we normally report the positive magnitude of the energy transferred out:
\[
\boxed{
P_{\text{out,avg}}
=-\frac{\Delta E_{\text{store}}}{\Delta t}
}
\]
This assumes the decrease in stored energy represents energy supplied to the external circuit, with no other energy transfers affecting the store.
The distinction depends on what the vertical axis represents:
| Energy graph | What a positive gradient means |
|---|---|
| Energy stored in a system | The system's stored energy is increasing |
| Energy transferred into a system | Energy is entering the system |
| Energy transferred out of a system | Energy is leaving the system |
A positive or negative gradient is not automatically good or bad. It tells you the direction of energy change under the convention used.
[IMAGE: A comparison of two graphs. The left graph shows a battery's stored energy decreasing with time, with a negative gradient. The right graph shows cumulative energy delivered by that battery increasing with time, with a positive gradient. Label both axes and use arrows to show that the two graphs describe the same energy transfer from different perspectives.]
## 2. A reliable method for reading a changing energy graph
When you encounter an energy-versus-time graph in an HSC question, follow this sequence.
**Step 1: Identify the energy being measured.**
Is it energy stored in a battery, gravitational potential energy, kinetic energy, or cumulative energy transferred?
This determines how you interpret the sign of the gradient.
**Step 2: Identify the requested time interval.**
Read the two relevant times from the horizontal axis. Do not automatically use the beginning and end of the entire graph.
**Step 3: Read the corresponding energy values.**
Call them \(E_1\) and \(E_2\), at times \(t_1\) and \(t_2\).
**Step 4: Calculate the gradient.**
\[
P_{\text{avg}}=
\frac{E_2-E_1}{t_2-t_1}
\]
Use consistent units.
**Step 5: Interpret the sign and state your answer.**
If the question asks for power supplied by a decreasing energy store, report the positive magnitude when the stated assumptions allow it. If it asks for the signed rate of change of the store, retain the negative sign.
[IMAGE: A clean annotated energy-time graph with two selectable-looking marked points, labelled (t1, E1) and (t2, E2), horizontal and vertical difference arrows labelled Δt and ΔE, and the secant gradient shown as ΔE/Δt. Do not include numerical answers.]
03Worked example: a battery with a changing discharge rate
A battery’s stored energy is recorded at four times during a discharge.
| Time (s) | Stored energy (kJ) |
|---|---|
| 0 | 42 |
| 4 | 34 |
| 8 | 28 |
| 12 | 24 |
Calculate the average power delivered by the battery over the first 12 seconds. Then calculate its average power from 4 s to 12 s.
Assume all the decrease in stored energy is transferred electrically to the external circuit.
Step 1: Identify the energy change.
The battery is losing stored energy, so its change in stored energy will be negative.
For the complete 12-second interval,
\[ \begin{aligned} \Delta E_{\text{store}} &=E_2-E_1\\\ &=24-42\\\ &=-18\text{ kJ} \end{aligned} \]
Step 2: Calculate the elapsed time.
\[ \Delta t=12-0=12\text{ s} \]
Step 3: Calculate the average power delivered.
Since we want the positive power supplied by the battery, take the negative of the rate of change of its stored energy.
\[ \begin{aligned} P_{\text{out,avg}} &=-\frac{\Delta E_{\text{store}}}{\Delta t}\\\ &=-\frac{-18}{12}\\\ &=1.5\text{ kW} \end{aligned} \]
The average power delivered over the first 12 seconds is therefore 1.5 kW.
Step 4: Repeat for the interval from 4 s to 12 s.
The stored energy decreases from 34 kJ to 24 kJ.
\[ \begin{aligned} P_{\text{out,avg}} &=-\frac{24-34}{12-4}\\\ &=\frac{10}{8}\\\ &=1.25\text{ kW} \end{aligned} \]
The average power over this shorter interval is 1.25 kW.
Step 5: Interpret the difference.
The battery delivers energy more quickly during the earlier part of the discharge.
We can confirm this by comparing the individual intervals:
| Time interval | Energy decrease | Average power delivered |
|---|---|---|
| 0-4 s | 8 kJ | 2.0 kW |
| 4-8 s | 6 kJ | 1.5 kW |
| 8-12 s | 4 kJ | 1.0 kW |
The graph becomes less steep as time passes. Its gradient decreases in magnitude, so the battery’s instantaneous discharge power also decreases.
Notice that the average power over the complete interval is not the same as the average power over the final 8 seconds. Always use the two points that match the interval in the question.
04Efficiency: when the graph shows more than one energy transfer
So far, we’ve looked at the energy stored in a system. But some questions provide two energy-versus-time graphs.
For example, imagine an electric motor connected to a mechanical load.
Electrical energy enters the motor. Some becomes useful mechanical energy transferred to the load, while the rest is transferred in non-useful forms, such as heating and sound.
The motor’s efficiency tells us what fraction of its input energy becomes useful output energy.
\[ \boxed{ \eta= \frac{E_{\text{useful,out}}}{E_{\text{input}}} \times100\% } \]
Here, \(\eta\) is efficiency, expressed as a percentage.
You can also calculate efficiency using average powers, provided both are measured over the same time interval:
\[ \boxed{ \eta= \frac{P_{\text{useful,out,avg}}} {P_{\text{input,avg}}} \times100\% } \]
Why does this work?
Both average powers are calculated by dividing their respective energy changes by the same elapsed time. The time cancels when you divide the two powers.
This gives us an important graph-reading rule:
- The gradient of the cumulative input-energy graph gives average input power.
- The gradient of the cumulative useful-output-energy graph gives average useful output power.
- The ratio of these gradients gives efficiency, provided both gradients refer to the same interval.
Worked example: finding motor power and efficiency from two curves
An electric motor is tested. The cumulative electrical energy supplied to it and the cumulative useful mechanical energy transferred to its load are recorded.
The illustrative data are:
| Time (s) | Electrical input (kJ) | Useful mechanical output (kJ) |
|---|---|---|
| 0 | 0 | 0 |
| 2 | 5.0 | 3.5 |
| 6 | 13.0 | 8.5 |
| 10 | 21.0 | 14.3 |
Calculate the average electrical input power, average useful output power, and efficiency between 2 s and 10 s.
Assume all input energy not converted into useful mechanical output is transferred to the surroundings as non-useful energy.
Step 1: Find the change in electrical input energy.
Between 2 s and 10 s,
\[ \begin{aligned} \Delta E_{\text{input}} &=21.0-5.0\\\ &=16.0\text{ kJ} \end{aligned} \]
Step 2: Calculate average input power.
\[ \begin{aligned} P_{\text{input,avg}} &=\frac{\Delta E_{\text{input}}}{\Delta t}\\\ &=\frac{16.0}{10-2}\\\ &=2.0\text{ kW} \end{aligned} \]
Step 3: Find the change in useful output energy.
\[ \begin{aligned} \Delta E_{\text{useful}} &=14.3-3.5\\\ &=10.8\text{ kJ} \end{aligned} \]
Step 4: Calculate average useful output power.
\[ \begin{aligned} P_{\text{useful,avg}} &=\frac{\Delta E_{\text{useful}}}{\Delta t}\\\ &=\frac{10.8}{8}\\\ &=1.35\text{ kW} \end{aligned} \]
Step 5: Calculate efficiency.
\[ \begin{aligned} \eta &=\frac{P_{\text{useful,avg}}} {P_{\text{input,avg}}} \times100\%\\\ &=\frac{1.35}{2.0}\times100\%\\\ &=67.5\% \end{aligned} \]
The motor’s average electrical input power is 2.0 kW, its average useful output power is 1.35 kW, and its efficiency over this interval is 67.5%.
Step 6: Check the energy balance.
The energy not converted into useful mechanical output is
\[ \begin{aligned} E_{\text{non-useful}} &=16.0-10.8\\\ &=5.2\text{ kJ} \end{aligned} \]
This corresponds to an average non-useful energy-transfer rate of
\[ P_{\text{non-useful,avg}} =\frac{5.2}{8} =0.65\text{ kW} \]
Our energy accounting checks out:
\[ 2.0=1.35+0.65 \]
The input power is divided between useful output and non-useful energy transfers.
A common efficiency mistake: using the wrong interval
Suppose you were asked to calculate the efficiency between 2 s and 10 s.
You might be tempted to divide the energy values at 10 s:
\[ \frac{14.3}{21.0}\times100\% \]
That gives approximately 68.1%.
However, this calculates the cumulative efficiency from the beginning of the experiment, not the efficiency between 2 s and 10 s.
For the requested interval, you must subtract the starting values first:
\[ \frac{14.3-3.5}{21.0-5.0} \times100\%=67.5\% \]
The difference is small in this example, but it can be substantial in an exam question.
Always calculate energy changes over the requested interval before finding average power or efficiency.
05Common graph-reading mistakes
| Tempting approach | Why it fails | Better approach |
|---|---|---|
| Read the energy value at the final time and divide by time | Ignores the starting energy | Calculate \(\Delta E\) first |
| Use the tangent gradient for average power | A tangent gives instantaneous power | Use the secant between the selected points |
| Ignore a negative gradient | Confuses energy leaving a store with energy entering it | State the system and sign convention |
| Calculate the area under an energy-time graph | The area has units of energy × time, not power | Calculate the gradient |
| Use the total graph’s endpoints for every question | The question may specify a shorter interval | Read the exact starting and finishing points |
| Divide useful energy by total energy at the final time when the interval starts later | Uses the wrong energy changes | Subtract both starting values |
| Treat the rate of decrease of stored energy as total output power when other inputs are present | A store’s gradient measures its net energy change | Account for every energy transfer across the system boundary |
One final point: a curved energy graph does not mean you cannot calculate average power. It simply means the instantaneous rate is changing. The secant still gives the correct average over any specified interval.
04Questions and solutions
Question 1
A rechargeable battery has the following stored-energy measurements during discharge.
| Time (s) | Stored energy (kJ) |
|---|---|
| 0 | 48 |
| 5 | 42 |
| 10 | 36 |
Assuming all the decrease in stored energy is transferred to an external circuit, calculate the average power delivered by the battery between 0 s and 10 s.
Solution 1
The average power delivered by the battery is 1.2 kW.
The battery’s stored energy decreases, so we use the negative of its rate of change to calculate the positive power delivered outwards.
First, calculate the energy change:
\[ \begin{aligned} \Delta E_{\text{store}} &=36-48\\\ &=-12\text{ kJ} \end{aligned} \]
The elapsed time is
\[ \Delta t=10-0=10\text{ s} \]
Therefore,
\[ \begin{aligned} P_{\text{out,avg}} &=-\frac{\Delta E_{\text{store}}}{\Delta t}\\\ &=-\frac{-12}{10}\\\ &=1.2\text{ kW} \end{aligned} \]
The battery delivers an average of 1.2 kJ of energy each second.
Notice that we used the change in stored energy, rather than simply dividing the final energy value by the elapsed time.
Question 2
A portable power bank is discharged over 10 seconds. Its stored energy is recorded at three points.
| Time (s) | Stored energy (kJ) |
|---|---|
| 0 | 50 |
| 4 | 34 |
| 10 | 22 |
Assume all the decrease in stored energy is transferred electrically to an external device.
(a) Calculate the average power delivered over the complete 10 seconds.
(b) Calculate the average power delivered during the first 4 seconds and during the following 6 seconds.
(c) A student calculates the overall average power by taking the arithmetic mean of the two answers from part (b). Explain why this method is incorrect.
Solution 2
The overall average power is 2.8 kW. The first interval has an average power of 4.0 kW, while the second has an average power of 2.0 kW.
(a) Overall average power
The total decrease in stored energy is
\[ \begin{aligned} \Delta E_{\text{store}} &=22-50\\\ &=-28\text{ kJ} \end{aligned} \]
The total elapsed time is 10 seconds.
Therefore,
\[ \begin{aligned} P_{\text{out,avg}} &=-\frac{-28}{10}\\\ &=2.8\text{ kW} \end{aligned} \]
(b) Average power during each interval
For the first 4 seconds, the energy decreases from 50 kJ to 34 kJ.
\[ \begin{aligned} P_1 &=-\frac{34-50}{4-0}\\\ &=\frac{16}{4}\\\ &=4.0\text{ kW} \end{aligned} \]
For the following 6 seconds, the energy decreases from 34 kJ to 22 kJ.
\[ \begin{aligned} P_2 &=-\frac{22-34}{10-4}\\\ &=\frac{12}{6}\\\ &=2.0\text{ kW} \end{aligned} \]
(c) Why the arithmetic mean is incorrect
The arithmetic mean would give
\[ \frac{4.0+2.0}{2}=3.0\text{ kW} \]
This is incorrect because the two power values apply to intervals of different lengths.
The first power operates for 4 seconds, while the second operates for 6 seconds. The longer interval must contribute more to the overall average.
We can check the correct result by weighting each power by its duration:
\[ \begin{aligned} P_{\text{avg}} &=\frac{(4.0)(4)+(2.0)(6)}{10}\\\ &=\frac{28}{10}\\\ &=2.8\text{ kW} \end{aligned} \]
The important idea is that an overall average power is weighted by time, not calculated by simply averaging the power values from different intervals.
Question 3
An electric motor is tested, and two cumulative energy measurements are recorded.
- \(E_{\text{input}}\) is the total electrical energy supplied to the motor.
- \(E_{\text{useful}}\) is the total useful mechanical energy transferred to its load.
The illustrative data are:
| Time (s) | \(E_{\text{input}}\) (kJ) | \(E_{\text{useful}}\) (kJ) |
|---|---|---|
| 0 | 0 | 0 |
| 3 | 7.0 | 4.2 |
| 6 | 13.0 | 8.4 |
| 9 | 19.0 | 13.2 |
Calculate:
(a) The average electrical input power between 3 s and 9 s.
(b) The average useful mechanical output power over the same interval.
(c) The motor’s efficiency over this interval.
(d) The average rate of non-useful energy transfer, assuming the remaining input energy is dissipated to the surroundings.
Solution 3
The average input power is 2.0 kW, the average useful output power is 1.5 kW, and the motor’s efficiency is 75%.
(a) Average electrical input power
The relevant energy change is between 3 s and 9 s, not between 0 s and 9 s.
\[ \begin{aligned} \Delta E_{\text{input}} &=19.0-7.0\\\ &=12.0\text{ kJ} \end{aligned} \]
The time interval is
\[ \Delta t=9-3=6\text{ s} \]
Therefore,
\[ \begin{aligned} P_{\text{input,avg}} &=\frac{12.0}{6}\\\ &=2.0\text{ kW} \end{aligned} \]
(b) Average useful mechanical output power
The useful energy change is
\[ \begin{aligned} \Delta E_{\text{useful}} &=13.2-4.2\\\ &=9.0\text{ kJ} \end{aligned} \]
Therefore,
\[ \begin{aligned} P_{\text{useful,avg}} &=\frac{9.0}{6}\\\ &=1.5\text{ kW} \end{aligned} \]
(c) Motor efficiency
Efficiency is the ratio of useful output energy to total input energy.
\[ \begin{aligned} \eta &=\frac{\Delta E_{\text{useful}}} {\Delta E_{\text{input}}} \times100\%\\\ &=\frac{9.0}{12.0}\times100\%\\\ &=75\% \end{aligned} \]
We could also use the average powers:
\[ \eta=\frac{1.5}{2.0}\times100\%=75\% \]
Both methods give the same answer because they use the same time interval.
(d) Average rate of non-useful energy transfer
The non-useful energy transferred is
\[ \begin{aligned} E_{\text{non-useful}} &=12.0-9.0\\\ &=3.0\text{ kJ} \end{aligned} \]
Therefore,
\[ \begin{aligned} P_{\text{non-useful,avg}} &=\frac{3.0}{6}\\\ &=0.50\text{ kW} \end{aligned} \]
The motor’s energy balance is
\[ 2.0=1.5+0.50 \]
This confirms that the input power is accounted for by the useful output and non-useful energy transfers.
A final trap is worth noticing. If you had divided the energy values at 9 seconds, you would have obtained \(13.2/19.0\), or approximately 69.5%. That is the cumulative efficiency from the beginning of the test, not the efficiency over the requested 3-9 second interval.
Question 4
A flywheel is connected to a reversible motor-generator. The motor-generator can transfer energy into the flywheel or receive energy back from it.
The flywheel’s stored mechanical energy changes as follows:
| Time (s) | Stored mechanical energy (kJ) |
|---|---|
| 0 | 10 |
| 3 | 22 |
| 9 | 16 |
The graph consists of two straight-line segments.
Use the sign convention that power supplied by the motor-generator to the flywheel is positive. Power transferred from the flywheel back to the motor-generator is negative.
Calculate:
(a) The signed average power over the complete 9-second interval.
(b) The average power during each of the two intervals.
(c) The time-averaged magnitude of power transfer over the complete interval, using the given constant power within each segment.
Explain why the answer to part (c) differs from part (a).
Solution 4
The signed average power over the complete interval is +0.67 kW. The motor-generator supplies energy at 4.0 kW during the first interval and receives energy back at an average rate of 1.0 kW during the second.
The time-averaged magnitude of power transfer is 2.0 kW.
(a) Signed average power over 9 seconds
The flywheel’s total change in stored energy is
\[ \begin{aligned} \Delta E &=16-10\\\ &=+6\text{ kJ} \end{aligned} \]
Therefore,
\[ \begin{aligned} P_{\text{avg}} &=\frac{\Delta E}{\Delta t}\\\ &=\frac{6}{9}\\\ &=+0.67\text{ kW} \end{aligned} \]
The positive sign means the motor-generator has transferred a net 6 kJ into the flywheel.
(b) Average power during each interval
During the first 3 seconds, the flywheel gains 12 kJ.
\[ \begin{aligned} P_1 &=\frac{22-10}{3-0}\\\ &=\frac{12}{3}\\\ &=+4.0\text{ kW} \end{aligned} \]
During the following 6 seconds, the flywheel loses 6 kJ.
\[ \begin{aligned} P_2 &=\frac{16-22}{9-3}\\\ &=\frac{-6}{6}\\\ &=-1.0\text{ kW} \end{aligned} \]
The negative sign indicates that energy is being transferred out of the flywheel and back to the motor-generator.
(c) Time-averaged magnitude of power transfer
For this part, we ignore the direction of energy transfer and average the magnitudes of the power values.
Because each segment has constant power,
\[ \begin{aligned} P_{\text{magnitude,avg}} &=\frac{(4.0)(3)+(1.0)(6)}{9}\\\ &=\frac{18}{9}\\\ &=2.0\text{ kW} \end{aligned} \]
Why are the answers different?
The signed average power accounts for energy transferred in both directions.
The motor-generator initially transfers 12 kJ into the flywheel. It then receives 6 kJ back.
The net energy transfer into the flywheel is therefore only 6 kJ.
However, the total magnitude of energy transferred is
\[ 12+6=18\text{ kJ} \]
Dividing this by 9 seconds gives 2.0 kW.
The distinction is between net energy transfer and total energy throughput.
If an HSC question asks for average power, use the signed energy change under the stated convention. Only calculate the average magnitude when the question specifically asks for it.
Question 5
A solar-powered cart has a solar panel, a rechargeable battery, and an electric motor.
The solar panel and battery are connected to a common electrical supply bus, which powers the motor. The battery’s stored chemical energy can decrease while the solar panel is simultaneously supplying electrical energy to the system.
The following illustrative measurements are recorded:
| Time (s) | Battery stored energy (kJ) | Cumulative solar energy supplied (kJ) |
|---|---|---|
| 0 | 50 | 0 |
| 5 | 47 | 7 |
| 10 | 44 | 12 |
Over the complete 10-second interval:
- The controller and connecting wires dissipate 1.0 kJ of energy.
- The motor has an efficiency of 75%.
- All electrical energy remaining after the controller and wiring losses enters the motor.
- The motor’s efficiency applies over the complete interval.
- There are no other energy inputs, outputs, or changes in energy stores within the system being considered.
A student looks at the battery’s energy graph and argues:
“The battery loses 6 kJ in 10 seconds, so the motor must receive electrical energy at an average rate of 0.60 kW.”
(a) Explain why the student’s reasoning is incorrect.
(b) Calculate the total electrical energy entering the motor.
(c) Calculate the total useful mechanical energy transferred by the motor.
(d) Calculate the average useful mechanical output power of the motor.
Solution 5
The student’s conclusion is incorrect. The motor receives 17 kJ of electrical energy, giving a useful mechanical output of 12.75 kJ and an average useful output power of 1.275 kW.
The key issue is that the battery is not the only source of energy. The solar panel is also supplying energy to the electrical bus.
(a) Why the student’s reasoning is incorrect
The battery’s stored energy decreases by
\[ \begin{aligned} \Delta E_{\text{battery}} &=44-50\\\ &=-6\text{ kJ} \end{aligned} \]
The average rate of decrease in the battery’s stored energy is therefore
\[ -\frac{\Delta E_{\text{battery}}}{\Delta t} =\frac{6}{10} =0.60\text{ kW} \]
This tells us the net rate at which the battery’s stored energy decreases.
It does not tell us the total electrical power entering the motor.
The solar panel supplies an additional 12 kJ during the same interval. The motor can therefore receive more energy than the amount by which the battery’s store decreases.
(b) Total electrical energy entering the motor
We use conservation of energy.
The total energy supplied to the electrical system comes from two contributions:
- 12 kJ from the solar panel.
- 6 kJ from the net decrease in the battery’s stored energy.
The total available energy is
\[ E_{\text{available}}=12+6=18\text{ kJ} \]
The controller and wiring dissipate 1.0 kJ.
Therefore,
\[ \begin{aligned} E_{\text{motor,input}} &=18-1.0\\\ &=17\text{ kJ} \end{aligned} \]
The motor receives 17 kJ of electrical energy.
(c) Total useful mechanical energy transferred
The motor’s efficiency is 75%.
Therefore,
\[ \begin{aligned} \eta &=\frac{E_{\text{useful}}} {E_{\text{input}}}\\\ 0.75&=\frac{E_{\text{useful}}}{17} \end{aligned} \]
Rearranging,
\[ \begin{aligned} E_{\text{useful}} &=0.75\times17\\\ &=12.75\text{ kJ} \end{aligned} \]
The motor transfers 12.75 kJ of useful mechanical energy to the cart.
(d) Average useful mechanical output power
The complete interval is 10 seconds.
\[ \begin{aligned} P_{\text{useful,avg}} &=\frac{E_{\text{useful}}}{\Delta t}\\\ &=\frac{12.75}{10}\\\ &=1.275\text{ kW} \end{aligned} \]
The average useful mechanical output power is therefore
\[ \boxed{1.275\text{ kW}} \]
We can check the energy accounting:
| Energy transfer | Energy (kJ) |
|---|---|
| Solar panel supplies | 12.00 |
| Battery’s net energy depletion | 6.00 |
| Controller and wiring losses | 1.00 |
| Motor’s useful mechanical output | 12.75 |
| Motor’s non-useful energy transfer | 4.25 |
The total energy supplied is 18 kJ, and the total energy accounted for is also 18 kJ.
The tempting mistake was to assume that the gradient of the battery’s stored-energy graph must equal the motor’s input power. That would only be justified if the battery were the sole energy source and the relevant energy transfers were fully accounted for.
This is why identifying the system and its energy transfers is just as important as calculating the gradient.
06Where to go next
The essential skill is recognising that an energy-versus-time graph gives you an amount of energy at each moment, while its gradient tells you the rate at which that energy changes.
For a curved graph, the secant gradient gives average power over a chosen interval. The tangent gradient gives instantaneous power at a particular moment.
Once you can distinguish these two, the natural next step is understanding how instantaneous power connects to force and motion through \(P=Fv\), for a force acting in the direction of motion.
For a broader introduction to work, energy changes, and average power calculations, see Average Power in HSC Physics: Energy Change Over Time.