tutorgum
Try a Class

How to Find Generator Rotation Frequency from an Output Graph

Learn how to calculate a generator's rotation frequency from its voltage-time graph, including the difference between slip-ring AC and split-ring DC outputs. Follow worked examples, understand the link between magnetic flux and induced emf, and practise with fully explained HSC Physics questions.

An oscilloscope shows a positive voltage peak at \(0.010\,\text{s}\) and another at \(0.030\,\text{s}\). Does that mean the generator completes one revolution every \(0.020\,\text{s}\)?

Not necessarily. With slip rings, successive positive peaks of an alternating-current (AC) waveform are one full revolution apart. With a split-ring commutator, successive positive peaks are only half a revolution apart.

For an ideal, single-coil generator rotating steadily between one north and one south magnetic pole, the method is:

  • Slip rings: Measure the time \(T\) between consecutive positive peaks of the signed AC waveform. The rotation frequency is \(f_r=1/T\).
  • Split-ring commutator: Measure the time \(T_p\) between consecutive positive pulses. The rotation frequency is \(f_r=1/(2T_p)\).

Here, \(f_r\) is the mechanical rotation frequency in hertz (Hz), meaning revolutions per second.

So a peak separation of \(0.020\,\text{s}\) could indicate \(50\,\text{Hz}\) with slip rings or \(25\,\text{Hz}\) with a split ring. The electrical output repeats at different rates because the contacts connect the rotating coil to the stationary circuit differently.

01The experiment: does one voltage cycle equal one revolution?

Imagine testing a generator whose rotation speed you cannot measure directly. You can only observe the voltage between its two output terminals.

The aim is to work backwards from the waveform to the motion of the shaft.

Follow the apparatus from the coil to the oscilloscope

Start with a rectangular wire coil positioned between two magnetic poles.

The north pole is on the left, the south pole is on the right, and the magnetic field points horizontally from north to south.

A shaft passes through the centre of the coil. Its axis lies in the plane of the coil and is perpendicular to the magnetic field. A motor turns the shaft, continuously changing the coil’s orientation.

Each end of the wire coil connects to a rotating metal contact. Stationary brushes press against these contacts and carry the electrical output to an oscilloscope.

Call the brushes P and Q. The oscilloscope measures

\[ V_{PQ}=V_P-V_Q \]

where \(V_P\) and \(V_Q\) are the electric potentials at the two brushes, measured in volts.

A positive reading means P is at a higher potential than Q. A negative reading means Q is at a higher potential than P.

For this comparison, assume a high-impedance oscilloscope, negligible internal resistance, ideal brushes, a uniform magnetic field, and a constant rotation speed. These assumptions allow the measured terminal voltage to represent the induced emf, with any changes of polarity caused by the contacts.

The question is what those contacts do.

First arrangement: two slip rings

Each end of the coil connects permanently to its own complete metal ring.

As the shaft rotates, the rings slide beneath their stationary brushes. The same coil end always remains connected to the same external brush.

Predict the output.

If the induced emf inside the coil reverses direction every half-turn, what should the oscilloscope display?

A positive half-cycle followed by a negative half-cycle.

The complete positive-negative pattern repeats after one full revolution. Therefore, for this simple generator, the AC waveform frequency equals the rotation frequency.

The slip rings maintain electrical connections while the coil rotates. They do not reverse those connections to compensate for changes in induced emf.

Revised arrangement: a split-ring commutator

Now keep the coil, magnetic field, and rotation speed unchanged, but replace the two complete rings with two insulated semicircular segments.

Each segment connects to one end of the coil.

As the assembly completes a half-turn, the segments exchange which stationary brush they contact. The external connections reverse just as the induced emf inside the coil reverses.

Under correct commutator timing, the negative half of the internal AC waveform appears as another positive pulse at the external terminals.

The result is pulsating direct current (DC): a voltage that has one polarity but repeatedly rises and falls.

The coil still generates alternating emf. The commutator changes which coil end connects to each external brush.

For a fuller explanation of the switching mechanism, see How a Split-Ring Commutator Changes a Generator’s Waveform.

But why exactly two pulses per revolution?

02The geometry explains the waveform

Picture the coil rotating through four positions: \(0^\circ\), \(90^\circ\), \(180^\circ\), and \(270^\circ\).

To describe its orientation, imagine an arrow perpendicular to the flat surface of the coil. This is called the coil’s area normal.

Let \(\theta\) be the angle between that chosen normal and the magnetic field.

At \(\theta=0^\circ\), the normal points along the field. The magnetic flux through the coil is maximum.

After a quarter-turn, at \(90^\circ\), the normal is perpendicular to the field. The flux is zero.

That might sound like the moment when the induced emf should also be zero. It isn’t.

The important quantity is how quickly the flux changes, not how much flux exists at an instant.

Magnetic flux and induced emf

For a coil in a uniform magnetic field, the magnetic flux through one turn is

\[ \Phi=BA\cos\theta \]

where:

  • \(\Phi\) is magnetic flux through one turn, in webers (Wb).
  • \(B\) is magnetic flux density, in teslas (T).
  • \(A\) is the area enclosed by one turn, in square metres (\(\text{m}^2\)).
  • \(\theta\) is the angle between the chosen area normal and the magnetic field.

When the coil rotates, \(\theta\) changes, so the flux changes.

Faraday’s law relates that change to the induced emf:

\[ e=-N\frac{d\Phi}{dt} \]

Here, \(e\) is the signed induced emf in volts, \(N\) is the number of turns, and \(t\) is time in seconds. The derivative \(d\Phi/dt\) means the instantaneous rate of change of flux.

The negative sign represents Lenz’s law: the induced emf has a polarity that opposes the change in flux producing it.

For steady rotation, define the angular speed \(\omega\), measured in radians per second (\(\text{rad s}^{-1}\)).

Taking \(\theta=0\) at \(t=0\) and choosing the positive rotation and winding directions consistently,

\[ \begin{aligned} \theta&=\omega t\\ e&=NBA\omega\sin\theta \end{aligned} \]

The peak emf is

\[ E_0=NBA\omega \]

so the induced emf becomes

\[ e=E_0\sin\theta \]

The important relationship is that magnetic flux follows a cosine pattern, while induced emf follows a sine pattern.

At maximum or minimum flux, the flux is momentarily changing at zero rate, so the induced emf is zero.

At zero flux, the flux is changing most rapidly during steady rotation, so the induced emf has its greatest magnitude.

This is the link between the coil’s geometry and the waveform’s timing.

If you need more practice with the gradient itself, see How to Read a Magnetic-Flux-Time Graph to Calculate EMF.

What happens over one complete revolution?

The following table uses illustrative values for an ideal generator with a mechanical rotation period of \(0.040\,\text{s}\) and a peak induced emf of \(6.0\,\text{V}\).

The coil starts at maximum positive flux at \(t=0\). Brush polarity is chosen so the first induced half-cycle is positive.

Time (s)Coil angleSlip-ring outputSplit-ring output
0.000\(0^\circ\)\(0\,\text{V}\)\(0\,\text{V}\)
0.010\(90^\circ\)\(+6.0\,\text{V}\)\(+6.0\,\text{V}\)
0.020\(180^\circ\)\(0\,\text{V}\)\(0\,\text{V}\)
0.030\(270^\circ\)\(-6.0\,\text{V}\)\(+6.0\,\text{V}\)
0.040\(360^\circ\)\(0\,\text{V}\)\(0\,\text{V}\)
0.050\(450^\circ\)\(+6.0\,\text{V}\)\(+6.0\,\text{V}\)

These are theoretical values, not experimental measurements.

Notice the difference at \(t=0.030\,\text{s}\). The emf inside the coil is negative in both arrangements, but the split-ring commutator has reversed the external connections.

One complete revolution takes \(0.040\,\text{s}\) in both arrangements.

For slip rings, successive positive peaks are separated by \(0.040\,\text{s}\).

For a split ring, successive positive peaks are separated by \(0.020\,\text{s}\).

The split ring has doubled the rate at which positive pulses appear, not the shaft’s speed.

03A reliable method for reading the output graph

The first decision is whether the graph shows signed AC voltage, pulsating DC voltage, or voltage magnitude.

Look at the vertical axis and the shape of the trace before using a formula.

Which two points should you measure?

Let \(\Delta t\) be the time interval between the two features you choose, measured in seconds.

Graph and chosen featuresMechanical period \(T_r\)Rotation frequency \(f_r\)
Signed slip-ring AC: positive peak to next positive peak\(\Delta t\)\(1/\Delta t\)
Signed slip-ring AC: positive peak to next negative peak\(2\Delta t\)\(1/(2\Delta t)\)
Ideal split-ring DC: positive peak to next positive peak\(2\Delta t\)\(1/(2\Delta t)\)
Voltage magnitude \(\lvert V\rvert\): consecutive peaks\(2\Delta t\)\(1/(2\Delta t)\)

The last row applies to an ideal single coil rotating steadily in a field with one north-south pole pair.

You can use consecutive zero crossings as well, but only when you understand why each zero occurs and know the shaft is rotating steadily.

The general frequency equation is

\[ f_r=\frac{1}{T_r} \]

where \(T_r\) is the time for one full mechanical revolution.

You can also convert between rotation frequency and angular speed:

\[ \omega=2\pi f_r \]

Or convert hertz to revolutions per minute:

\[ \text{rpm}=60f_r \]

Why a graph showing only positive values can be misleading

Imagine the generator still uses slip rings, but the data logger is set to display the magnitude of voltage, \(\lvert V\rvert\).

It now displays the negative half-cycles as positive values.

The resulting graph looks like the ideal output of a split-ring generator, even though nothing has changed inside the generator.

So a positive-only trace does not prove that the apparatus contains a split-ring commutator.

To improve the original measurement, use a signed oscilloscope rather than an absolute-value display. Inspect the contacts, or add a reference sensor that produces one signal for every complete shaft revolution.

For example, a single reflective mark on the shaft can trigger an optical sensor once per turn. Comparing those reference signals with the voltage peaks shows how many electrical pulses occur during one mechanical revolution.

This extra measurement matters because a voltage trace describes electrical repetition. It does not automatically identify the mechanical motion causing it.

04Worked example: Finding rotation frequency from an AC graph

An ideal AC generator uses two slip rings and rotates at constant speed between one north and one south magnetic pole.

Its signed output-voltage graph has consecutive positive peaks at \(t=0.025\,\text{s}\) and \(t=0.105\,\text{s}\). A negative peak occurs at \(t=0.065\,\text{s}\).

Calculate the generator’s rotation frequency in hertz and its speed in revolutions per minute.

Step 1

The generator uses slip rings, so one complete AC cycle corresponds to one full revolution.

Measure from one positive peak to the next positive peak, rather than from the positive peak to the negative peak.

Step 2

\[ \begin{aligned} T_r&=0.105-0.025\\ &=0.080\,\text{s} \end{aligned} \]

The shaft takes \(0.080\,\text{s}\) to complete one revolution.

Step 3

\[ \begin{aligned} f_r&=\frac{1}{T_r}\\ &=\frac{1}{0.080\,\text{s}}\\ &=12.5\,\text{Hz} \end{aligned} \]

Step 4

\[ \begin{aligned} \text{rpm}&=60f_r\\ &=60(12.5)\\ &=750\,\text{rpm} \end{aligned} \]

The generator rotates at \(12.5\,\text{Hz}\), or \(750\,\text{rpm}\).

The negative peak at \(0.065\,\text{s}\) occurs halfway between the positive peaks. That corresponds to half a mechanical revolution, not another full turn.

05Worked example: A split-ring graph with a peak-emf cross-check

A simple DC generator has a correctly timed split-ring commutator. It contains 50 turns, each enclosing an area of \(0.0040\,\text{m}^2\), and rotates in a uniform magnetic field of \(0.20\,\text{T}\).

An illustrative signed oscilloscope trace has positive voltage peaks of approximately \(5.0\,\text{V}\) at:

  • \(t=0.0125\,\text{s}\)
  • \(t=0.0375\,\text{s}\)
  • \(t=0.0625\,\text{s}\)

Find the rotation frequency and angular speed. Then test whether the measured peak voltage is consistent with the ideal generator model.

Assume steady rotation, negligible internal resistance, and ideal contacts.

Step 1

\[ \begin{aligned} T_p&=0.0375-0.0125\\ &=0.0250\,\text{s} \end{aligned} \]

For a correctly timed split-ring generator rotating at constant speed, this is the time for half a revolution.

Therefore,

\[ \begin{aligned} T_r&=2T_p\\ &=2(0.0250)\\ &=0.0500\,\text{s} \end{aligned} \]

Step 2

\[ \begin{aligned} f_r&=\frac{1}{0.0500}\\ &=20.0\,\text{Hz} \end{aligned} \]

The shaft completes 20 revolutions each second.

Step 3

\[ \begin{aligned} \omega&=2\pi f_r\\ &=2\pi(20.0)\\ &=125.7\,\text{rad s}^{-1} \end{aligned} \]

Step 4

For a rotating coil,

\[ E_0=NBA\omega \]

Substituting the given values,

\[ \begin{aligned} E_0&=50(0.20)(0.0040)(125.7)\\ &=5.03\,\text{V} \end{aligned} \]

The predicted peak emf is approximately \(5.0\,\text{V}\), which agrees with the illustrative oscilloscope reading to two significant figures.

That is a useful consistency test. The spacing of the pulses gives the speed, while their height depends on the magnetic field, number of turns, coil area, and speed.

A split-ring commutator does not double \(E_0\). It changes the polarity of alternate half-cycles at the external terminals.

06Three assumptions worth checking

Before treating an output graph as a rotation-speed measurement, establish these three things.

1. The electrical arrangement is known.

Slip rings preserve the alternating polarity of the induced emf. A correctly timed split-ring commutator produces pulses of one polarity for the intended direction of rotation and magnetic field.

A graph processed to show \(\lvert V\rvert\) can conceal this distinction.

2. The generator has the simple geometry assumed by the formula.

The one-cycle-per-revolution and two-pulses-per-revolution rules apply to a simple coil in a uniform field with one north-south pole pair.

Real generators may have multiple coils, multiple pole pairs, electronic rectification, or more complicated connections. Their electrical repetition rate need not have the same relationship to mechanical rotation.

3. The rotation is steady enough for a single period to make sense.

For a constant-speed generator, equal angular intervals take equal amounts of time.

If the shaft accelerates, slows down, or temporarily stops, the waveform changes shape and the time between pulses may change. A counted pulse rate may no longer give a reliable instantaneous rotation frequency.

The final practice question explores exactly why.

07Questions and solutions

Question 1

An ideal generator uses two slip rings and rotates at constant speed in a magnetic field with one north-south pole pair.

Its signed voltage-time graph shows consecutive positive peaks at \(0.020\,\text{s}\) and \(0.070\,\text{s}\). A negative peak occurs halfway between them.

Calculate:

a) The mechanical rotation period.

b) The rotation frequency in hertz.

c) The rotation speed in revolutions per minute.

Explain why the negative peak does not represent another complete revolution.

Solution 1

The mechanical period is \(0.050\,\text{s}\), the rotation frequency is \(20\,\text{Hz}\), and the rotation speed is \(1200\,\text{rpm}\).

For a simple slip-ring generator, one full positive-negative AC cycle corresponds to one mechanical revolution.

The time between consecutive positive peaks is

\[ \begin{aligned} T_r&=0.070-0.020\\ &=0.050\,\text{s} \end{aligned} \]

Therefore,

\[ \begin{aligned} f_r&=\frac{1}{T_r}\\ &=\frac{1}{0.050\,\text{s}}\\ &=20\,\text{Hz} \end{aligned} \]

Converting to revolutions per minute,

\[ \begin{aligned} \text{rpm}&=60(20)\\ &=1200\,\text{rpm} \end{aligned} \]

The negative peak occurs after half a revolution because the induced emf has reversed direction.

The tempting mistake is to count both the positive and negative peaks as complete revolutions. They are two opposite-polarity extrema within the same electrical cycle.

Question 2

An unknown simple generator operates at constant speed in a magnetic field with one north-south pole pair.

Its output is connected to a data logger set to display voltage magnitude, \(\lvert V_{PQ}\rvert\), rather than signed voltage.

Three consecutive positive peaks appear at:

  • \(0.006\,\text{s}\)
  • \(0.021\,\text{s}\)
  • \(0.036\,\text{s}\)

The magnitude falls to zero between successive peaks.

A technician concludes:

“The generator must contain a split-ring commutator because every displayed pulse is positive. Its shaft rotates at \(66.7\,\text{Hz}\).”

a) Calculate the actual mechanical rotation frequency under the stated ideal assumptions.

b) Explain whether the data establish that the generator uses a split ring.

c) Describe one follow-up electrical measurement that would distinguish slip rings from a correctly timed split-ring commutator. State the expected result for each arrangement.

Solution 2

The shaft rotates at approximately \(33.3\,\text{Hz}\), and the magnitude-only graph cannot identify the type of rings.

The technician’s conclusion is incorrect in both parts.

Part a: Calculate the frequency.

The interval between consecutive magnitude peaks is

\[ \begin{aligned} T_p&=0.021-0.006\\ &=0.015\,\text{s} \end{aligned} \]

A simple sinusoidal induced emf reaches two extrema in magnitude per complete rotation.

Taking the absolute value makes both extrema appear positive, regardless of whether the physical generator uses slip rings or a correctly timed split ring.

Therefore,

\[ \begin{aligned} T_r&=2T_p\\ &=2(0.015)\\ &=0.030\,\text{s} \end{aligned} \]

The rotation frequency is

\[ \begin{aligned} f_r&=\frac{1}{0.030}\\ &=33.3\,\text{Hz} \end{aligned} \]

The displayed pulse rate is approximately \(66.7\,\text{Hz}\), but the shaft makes only \(33.3\) revolutions per second.

Part b: Identify the limitation.

Both arrangements can produce the same magnitude-only graph:

  • Slip rings generate alternating positive and negative voltage, which the logger converts into positive magnitudes.
  • A correctly timed split ring already produces pulses of one polarity.

The data logger has removed the polarity information needed to distinguish them.

Part c: Improve the measurement.

Measure the signed voltage directly with the same fixed probe connections, without absolute-value processing or external rectification.

For slip rings, the trace should show alternating positive and negative half-cycles.

For a correctly timed split-ring generator, the trace should show pulses of one polarity.

The main trap is treating the shape of a processed graph as proof of the generator’s internal connections.

Question 3

A single-coil AC generator uses slip rings. Its number of turns and coil area remain fixed, but its rotation speed and magnetic field strength can be adjusted.

A high-impedance oscilloscope records two separate steady-state trials.

MeasurementTrial ATrial B
Peak voltage magnitude\(4.0\,\text{V}\)\(12.0\,\text{V}\)
First positive peak\(0.020\,\text{s}\)\(0.300\,\text{s}\)
Next positive peak\(0.100\,\text{s}\)\(0.340\,\text{s}\)

The time stamps belong to separate measurement windows. Ignore the transition between trials.

a) Calculate the generator’s rotation frequency in each trial.

b) Determine the ratio of angular speeds.

c) Determine the ratio of magnetic field strengths \(B_B/B_A\), assuming the ideal rotating-coil model applies.

d) Explain why the threefold increase in peak voltage does not mean the shaft rotates three times faster.

Solution 3

Trial A has a rotation frequency of \(12.5\,\text{Hz}\), Trial B has a rotation frequency of \(25.0\,\text{Hz}\), and the magnetic field in Trial B is \(1.5\) times as strong.

The voltage has tripled because both rotation speed and magnetic field strength have increased.

Part a: Find each frequency.

For Trial A,

\[ \begin{aligned} T_A&=0.100-0.020\\ &=0.080\,\text{s}\\ f_A&=\frac{1}{0.080}\\ &=12.5\,\text{Hz} \end{aligned} \]

For Trial B,

\[ \begin{aligned} T_B&=0.340-0.300\\ &=0.040\,\text{s}\\ f_B&=\frac{1}{0.040}\\ &=25.0\,\text{Hz} \end{aligned} \]

Part b: Compare angular speeds.

Since \(\omega=2\pi f_r\),

\[ \begin{aligned} \frac{\omega_B}{\omega_A} &=\frac{f_B}{f_A}\\ &=\frac{25.0}{12.5}\\ &=2.0 \end{aligned} \]

The shaft rotates twice as fast in Trial B.

Part c: Compare magnetic field strengths.

The peak emf is

\[ E_0=NBA\omega \]

Because \(N\) and \(A\) remain constant,

\[ \frac{E_B}{E_A} = \frac{B_B}{B_A} \frac{\omega_B}{\omega_A} \]

The peak voltage ratio is

\[ \frac{E_B}{E_A}=\frac{12.0}{4.0}=3.0 \]

Therefore,

\[ \begin{aligned} 3.0&=\frac{B_B}{B_A}(2.0)\\ \frac{B_B}{B_A}&=1.5 \end{aligned} \]

The magnetic field strength increased by a factor of \(1.5\), or 50%.

Part d: Explain the misconception.

Peak voltage depends on the product \(B\omega\) when the coil’s turns and area are fixed.

The waveform’s horizontal spacing establishes that the shaft speed doubled. If the magnetic field had stayed constant, the peak voltage would also have doubled, from \(4.0\,\text{V}\) to \(8.0\,\text{V}\).

The observed peak of \(12.0\,\text{V}\) requires the additional increase in magnetic field strength under the stated assumptions.

Graph height and graph spacing measure different aspects of the generator. You cannot infer speed from voltage amplitude alone.

Question 4

An ideal generator has 80 turns and rotates at constant speed in a uniform magnetic field with one north-south pole pair.

The signed magnetic flux through each turn follows this pattern:

Time (s)Flux per turn
0.000\(+2.0\,\text{mWb}\)
0.015\(0\)
0.030\(-2.0\,\text{mWb}\)
0.045\(0\)
0.060\(+2.0\,\text{mWb}\)

Here, \(1\,\text{mWb}=10^{-3}\,\text{Wb}\).

A signed oscilloscope connected to the stationary output brushes shows positive voltage peaks of approximately \(16.8\,\text{V}\) at both \(0.015\,\text{s}\) and \(0.045\,\text{s}\). The voltage is zero at \(0.000\,\text{s}\), \(0.030\,\text{s}\), and \(0.060\,\text{s}\).

Assume ideal contacts and negligible internal resistance.

a) Calculate the mechanical rotation frequency.

b) Calculate the predicted peak induced emf using the magnetic flux information.

c) Identify the type of contact arrangement consistent with the signed output.

d) If the contacts were replaced with two slip rings, with the probe orientation chosen to preserve the positive voltage at \(0.015\,\text{s}\), determine the voltage at \(0.045\,\text{s}\).

e) Explain why the voltage peaks occur when the magnetic flux is zero.

Solution 4

The generator rotates at approximately \(16.7\,\text{Hz}\), its predicted peak induced emf is \(16.8\,\text{V}\), and the signed output is consistent with a correctly timed split-ring commutator.

With slip rings instead, the voltage at \(0.045\,\text{s}\) would be approximately \(-16.8\,\text{V}\) under the specified polarity convention.

Part a: Find the rotation frequency.

The flux returns to the same positive maximum at \(0.060\,\text{s}\).

For the stated single-coil geometry and constant rotation speed, that represents one complete revolution.

\[ \begin{aligned} T_r&=0.060\,\text{s}\\ f_r&=\frac{1}{0.060}\\ &=16.7\,\text{Hz} \end{aligned} \]

Part b: Calculate the peak emf.

The maximum flux through one turn is

\[ \Phi_{\max}=2.0\times10^{-3}\,\text{Wb} \]

Because the flux varies sinusoidally,

\[ E_0=N\Phi_{\max}\omega \]

First calculate angular speed:

\[ \begin{aligned} \omega&=2\pi f_r\\ &=2\pi\left(\frac{1}{0.060}\right)\\ &=104.7\,\text{rad s}^{-1} \end{aligned} \]

Now substitute:

\[ \begin{aligned} E_0&=80(2.0\times10^{-3})(104.7)\\ &=16.8\,\text{V} \end{aligned} \]

This agrees with the stated peak voltage.

Part c: Identify the contacts.

The signed external voltage is positive at both successive half-turn emf extrema.

A simple slip-ring generator would preserve the alternating polarity of the internal emf. Its two successive extrema would have opposite signs.

A correctly timed split-ring commutator reverses the external connections between those extrema, producing two positive pulses.

Part d: Predict the slip-ring voltage.

At \(0.015\,\text{s}\), the flux is decreasing through zero.

Therefore, Faraday’s law gives a positive internal emf under the chosen winding convention.

At \(0.045\,\text{s}\), the flux is increasing through zero. The rate of change has the same magnitude but the opposite sign.

Thus,

\[ e(0.045\,\text{s})=-16.8\,\text{V} \]

With slip rings, the external voltage would retain that negative polarity.

Part e: Explain the timing.

Magnetic flux is zero when the coil’s area normal is perpendicular to the magnetic field.

During steady rotation, that is also when the flux is changing most rapidly.

Since induced emf depends on the rate of change of flux, its magnitude is maximum there.

The tempting prediction is that zero flux must produce zero induced emf. The error is confusing the value of flux with its rate of change.

Question 5

An ideal single-coil generator with a correctly timed split-ring commutator rotates in a constant, uniform magnetic field with one north-south pole pair.

The shaft always moves in the same forward direction, but its motor can slow down, momentarily stop, and then resume rotation. It is not guaranteed to rotate at constant speed.

A signed oscilloscope shows four separate positive voltage lobes between \(t=0\) and \(t=0.050\,\text{s}\). The lobes meet zero voltage at five instants, and there are no other voltage zeros during the interval.

An independent shaft encoder confirms that the coil completes exactly one full revolution between \(t=0\) and \(t=0.050\,\text{s}\).

Using the encoder’s orientation readings and the known magnetic field, the flux through one turn at each zero-voltage instant is determined:

Time (s)VoltageMagnetic flux per turn
0.000\(0\,\text{V}\)\(+2.0\,\text{mWb}\)
0.010\(0\,\text{V}\)\(0\)
0.025\(0\,\text{V}\)\(-2.0\,\text{mWb}\)
0.035\(0\,\text{V}\)\(0\)
0.050\(0\,\text{V}\)\(+2.0\,\text{mWb}\)

Assume that the magnetic field, coil area, and number of turns remain constant, the commutator operates correctly, and there are no contact interruptions or signal-processing effects.

A student argues:

“A split-ring generator gives two positive pulses per revolution. There are four positive lobes in \(0.050\,\text{s}\), so the generator must have completed two revolutions. Its rotation frequency is \(40\,\text{Hz}\).”

a) Determine the actual average rotation frequency over the measured interval.

b) Identify which of the five zero-voltage observations prove that the shaft’s instantaneous angular speed is zero. Explain why.

c) Explain why the other zero-voltage observations do not establish whether the shaft is moving or stationary at those exact instants.

d) Explain how a single-coil split-ring generator can produce four separate positive voltage lobes during just one revolution.

e) A second student claims that induced emf must be maximum whenever magnetic flux is zero. Explain why that claim fails for this experiment, even though it works for the usual constant-speed sinusoidal model.

Solution 5

The average rotation frequency is \(20\,\text{Hz}\), not \(40\,\text{Hz}\). The zero-voltage observations at \(0.010\,\text{s}\) and \(0.035\,\text{s}\) prove that the shaft has momentarily stopped. The zeros at the three flux extrema do not establish the instantaneous shaft speed.

Four positive lobes can occur in one revolution because temporary stops can divide the usual two half-turn pulses into smaller sections.

The crucial mistake is assuming that every zero in an induced-voltage graph represents a particular coil orientation.

Part a: Determine the actual average frequency.

The independent shaft encoder confirms one complete revolution during \(0.050\,\text{s}\).

Therefore,

\[ \begin{aligned} f_{r,\text{avg}}&=\frac{1}{0.050\,\text{s}}\\ &=20\,\text{Hz} \end{aligned} \]

This is the average rate of rotation over the measured revolution. Because the shaft speed varies, its instantaneous rotation frequency is not always \(20\,\text{Hz}\).

The four observed lobes do not override the encoder’s direct measurement of mechanical rotation.

Part b: Find the zeros that prove the shaft has stopped.

For a rotating coil, the instantaneous induced emf can be written as

\[ e=NBA\omega(t)\sin\theta \]

where \(\omega(t)\) is the instantaneous angular speed.

At \(t=0.010\,\text{s}\), the magnetic flux is zero.

Since

\[ \Phi=BA\cos\theta \]

and \(B\) and \(A\) are nonzero, zero flux means

\[ \cos\theta=0 \]

Therefore, the magnitude of \(\sin\theta\) is 1.

At this orientation, the induced emf magnitude is

\[ |e|=NBA|\omega(t)| \]

All three quantities \(N\), \(B\), and \(A\) are nonzero and constant.

But the observed terminal voltage is zero. With ideal commutation, that means the induced emf is zero.

The only remaining possibility is

\[ \omega(0.010\,\text{s})=0 \]

The shaft must be momentarily stationary.

The same argument applies at \(t=0.035\,\text{s}\), where flux and induced emf are again both zero.

Thus, the two times at which a stop is proved are:

  • \(t=0.010\,\text{s}\)
  • \(t=0.035\,\text{s}\)

This conclusion follows from the simultaneous flux and emf information, not from the voltage alone.

Part c: Examine the remaining voltage zeros.

At \(t=0\), \(0.025\,\text{s}\), and \(0.050\,\text{s}\), the flux has its maximum possible positive or negative magnitude.

That means

\[ |\cos\theta|=1 \]

and therefore

\[ \sin\theta=0 \]

Substituting into the induced emf equation,

\[ \begin{aligned} e&=NBA\omega(t)\sin\theta\\ &=0 \end{aligned} \]

This remains true even when the shaft is rotating.

Consequently, zero voltage at these orientations cannot tell us whether the angular speed is positive or momentarily zero.

The shaft may be moving straight through the position, or it may briefly stop there as well. The available observations do not distinguish those possibilities.

That is an important limit on what the voltage measurement can prove.

Part d: Explain the four positive lobes.

For steady rotation, a correctly timed split-ring generator produces one positive half-sine pulse during each half-turn.

But that assumes the angular speed does not fall to zero partway through a half-turn.

Here, the coil follows these successive orientations:

TimeCoil orientationPhysical interpretation
\(0.000\,\text{s}\)\(0^\circ\)Maximum positive flux
\(0.010\,\text{s}\)\(90^\circ\)Momentary stop
\(0.025\,\text{s}\)\(180^\circ\)Maximum negative flux
\(0.035\,\text{s}\)\(270^\circ\)Momentary stop
\(0.050\,\text{s}\)\(360^\circ\)One full revolution

During the first half-turn, the shaft moves from \(0^\circ\) towards \(90^\circ\), generating positive external voltage.

As it slows to rest at \(90^\circ\), the voltage falls to zero.

The shaft then resumes rotation from \(90^\circ\) towards \(180^\circ\), generating another positive voltage lobe before reaching the normal geometric zero at \(180^\circ\).

The same thing happens during the second half-turn, with another stop at \(270^\circ\).

So each half-turn contains two separate positive voltage lobes rather than one.

There are still only two geometric half-turns.

Part e: Explain the failure of the zero-flux rule.

At constant angular speed, the induced emf reaches its maximum magnitude when the flux passes through zero.

That result comes from

\[ |e|=NBA\omega|\sin\theta| \]

with \(\omega\) constant.

When the flux is zero, \(|\sin\theta|=1\), giving the largest magnitude of emf for that fixed speed.

But in this experiment, \(\omega\) is not constant.

At \(90^\circ\) and \(270^\circ\), the shaft has stopped, so

\[ \omega=0 \]

Even though the magnetic flux is zero,

\[ |e|=NBA(0)(1)=0\,\text{V} \]

The emf is zero because the flux is not changing at that instant.

More generally, when rotation speed varies, voltage depends on both orientation and instantaneous angular speed. Its maximum need not occur exactly at zero flux.

This is the conceptual limit of the familiar frequency shortcut.

Counting two positive pulses per revolution is reliable for the stated steady-speed, single-coil, correctly commutated model. It is not a universal law about every positive lobe that can appear on a voltage graph.

08The next measurement to make

Once you’ve extracted a rotation frequency from a generator’s voltage graph, ask what independent evidence supports the relationship between electrical repetition and mechanical rotation.

A known slip-ring or split-ring arrangement is often enough for an ideal constant-speed HSC question. For an unfamiliar or changing system, a shaft-reference measurement can test the assumption directly.

Then the height of the waveform becomes useful for a different question: whether a change in peak voltage was caused by rotation speed, magnetic field strength, or another property of the generator.

Keeping those two measurements separate – waveform timing for rotation and waveform amplitude for induced emf – is what makes the output graph genuinely informative.