How to Sketch AC Generator EMF from Coil Position

Learn how to sketch an AC generator's emf waveform from coil position using magnetic flux, Faraday's law, and the area normal. Includes worked examples, waveform comparisons, and the key differences between slip rings and split-ring commutators.

To sketch an AC generator’s emf from its coil position, track the angle between the magnetic field and the coil’s area normal, then work out how quickly the magnetic flux is changing. For a coil rotating at constant speed, the emf follows a predictable sequence:

  • At \(0^\circ\): zero emf.
  • At \(90^\circ\): maximum positive emf.
  • At \(180^\circ\): zero emf.
  • At \(270^\circ\): maximum negative emf.
  • At \(360^\circ\): zero emf again.

Join these points with a smooth sine curve. That’s the basic method for an AC generator with slip rings.

The important detail is that the emf depends on the rate of change of magnetic flux, not the amount of flux at that instant. Once you understand how the coil’s orientation changes the flux, sketching the waveform becomes much more straightforward.

01Start with the coil’s position

Picture a rectangular coil rotating between the north and south poles of a magnet. The magnetic field points from north to south, and the coil rotates at a constant angular speed.

To describe its position, we need one imaginary line: the area normal.

The area normal is a line perpendicular to the plane of the coil. Imagine an arrow sticking straight out of one face of the rectangular coil.

We measure the angle \(\theta\) between this arrow and the magnetic field.

This is important. The angle is measured from the normal, not from the flat surface of the coil.

What happens as the coil rotates?

Consider four important positions during one complete revolution.

Position 1: \(\theta=0^\circ\)

The area normal points directly along the magnetic field.

The plane of the coil is perpendicular to the field, so magnetic field lines pass straight through the enclosed area.

Magnetic flux is at its maximum positive value.

Position 2: \(\theta=90^\circ\)

The area normal is perpendicular to the magnetic field.

The plane of the coil is now parallel to the field. There is no magnetic flux passing through the enclosed area.

Magnetic flux is zero.

Position 3: \(\theta=180^\circ\)

The area normal points directly against the magnetic field.

The field passes through the opposite face of the coil, so magnetic flux reaches its maximum negative value.

Position 4: \(\theta=270^\circ\)

The area normal is perpendicular to the magnetic field again.

The plane of the coil is parallel to the field, so magnetic flux returns to zero.

At \(360^\circ\), the coil has completed one revolution and returned to its original orientation.

Connect position to magnetic flux

For a coil in a uniform magnetic field, magnetic flux through one turn is:

\[ \Phi=BA\cos\theta \]

where:

  • \(\Phi\) is magnetic flux, measured in webers (Wb).
  • \(B\) is magnetic field strength, measured in tesla (T).
  • \(A\) is the area enclosed by one turn, measured in square metres (\(\text{m}^2\)).
  • \(\theta\) is the angle between the magnetic field and the area normal.

Notice the cosine.

When \(\theta=0^\circ\), \(\cos0^\circ=1\), giving maximum positive flux.

When \(\theta=90^\circ\), \(\cos90^\circ=0\), giving zero flux.

When \(\theta=180^\circ\), \(\cos180^\circ=-1\), giving maximum negative flux.

You can use this relationship to work out the flux at any coil position.

However, knowing the flux is only half the job. We still need to determine the induced emf.

02Why the emf is different from the flux

Here’s the prediction that catches many students.

If magnetic flux is greatest at \(0^\circ\), should the induced emf also be greatest at \(0^\circ\)?

No. The induced emf is actually zero.

Faraday’s law explains why:

\[ \mathcal E=-N\frac{d\Phi}{dt} \]

Here:

  • \(\mathcal E\) is the induced emf, measured in volts (V).
  • \(N\) is the number of turns in the coil.
  • \(\Phi\) is magnetic flux through one turn, measured in webers.
  • \(d\Phi/dt\) represents the rate of change of magnetic flux.

The key idea is that the induced emf depends on how quickly the flux changes.

Think about a car travelling up a hill. At the highest point, its height is greatest, but that doesn’t mean its height is changing most quickly at that instant.

Magnetic flux behaves similarly. A large value of flux does not automatically mean a large induced emf.

Apply Faraday’s law to the rotating coil

As the coil rotates, its flux changes continuously.

At \(0^\circ\), flux is at a maximum. For an instant, it stops increasing and starts decreasing. Its rate of change is zero, so the induced emf is zero.

At \(90^\circ\), flux passes through zero and changes most rapidly. The magnitude of the induced emf is greatest.

At \(180^\circ\), flux reaches its negative maximum. Again, its rate of change is zero, so the emf is zero.

At \(270^\circ\), flux changes most rapidly in the opposite direction, producing maximum emf with the opposite polarity.

This gives us the relationship we need for sketching.

Coil positionMagnetic fluxInduced emf
\(0^\circ\)Maximum positiveZero
\(90^\circ\)ZeroMaximum positive
\(180^\circ\)Maximum negativeZero
\(270^\circ\)ZeroMaximum negative
\(360^\circ\)Maximum positiveZero

The signs above use a chosen terminal polarity and a coil rotating in the direction of increasing \(\theta\). Swapping the voltage sensor leads would reverse every emf sign, but the positions of the peaks and zero crossings would remain unchanged.

03The method for sketching emf from coil position

For an ideal AC generator rotating at constant angular speed in a uniform magnetic field, the induced emf is:

\[ \mathcal E=\mathcal E_{\max}\sin\theta \]

where:

  • \(\mathcal E\) is instantaneous induced emf (V).
  • \(\mathcal E_{\max}\) is maximum induced emf (V).
  • \(\theta\) is the coil’s rotation angle, measured from the initial position where the area normal is parallel to the field.

This equation assumes the chosen positive polarity and increasing rotation angle described above.

You don’t need to calculate every point on the curve. Instead, use the five important positions.

A reliable five-point sketching method

Step 1: Identify the angle convention.

Check whether the angle is measured between the magnetic field and the coil’s normal or between the field and the plane of the coil.

If the question gives the angle to the plane, don’t substitute it directly into the cosine expression for flux.

Step 2: Find the starting position.

If the area normal initially points along the magnetic field, start at \(\theta=0^\circ\).

This means the emf starts at zero.

Step 3: Mark the quarter-turn positions.

For one complete revolution, mark:

\[ 0^\circ,\quad90^\circ,\quad180^\circ, \quad270^\circ,\quad360^\circ \]

Step 4: Add the emf values.

Use:

\[ 0,\quad+\mathcal E_{\max},\quad 0,\quad-\mathcal E_{\max},\quad0 \]

Step 5: Join the points smoothly.

Draw a sinusoidal curve through the five points.

Do not draw straight lines between them. The emf changes continuously as the coil rotates.

What if the horizontal axis is time instead?

The same method works.

For constant angular speed:

\[ \theta=\omega t \]

where \(\omega\) is angular speed in radians per second and \(t\) is time in seconds.

One complete revolution corresponds to one complete electrical cycle for this single-coil generator.

Therefore, the important time positions are:

TimeCoil angleInduced emf
\(0\)\(0^\circ\)Zero
\(T/4\)\(90^\circ\)Maximum positive
\(T/2\)\(180^\circ\)Zero
\(3T/4\)\(270^\circ\)Maximum negative
\(T\)\(360^\circ\)Zero

Here, \(T\) is the time taken for one complete revolution.

If the question gives you a time axis, the waveform must have the correct period. Don’t simply draw a sine wave with arbitrary spacing.

One more detail: if the coil starts at a different orientation, the waveform will have a different starting phase. The five-point method still works, but you must account for the initial angle.

How could we test whether the predicted relationship is correct?

The problem is not simply measuring voltage. We need to know the coil’s exact position at the instant each voltage reading is taken.

Setting up the investigation

Picture the apparatus in the following order.

  1. A rectangular coil sits between two magnetic pole pieces, with a uniform magnetic field across the gap.
  2. The coil is attached to a shaft that passes through its centre.
  3. An electric motor rotates the shaft at a controlled speed.
  4. Each end of the coil connects to a separate continuous slip ring mounted on the shaft.
  5. Stationary conducting brushes press against the slip rings.
  6. Wires connect the brushes to a voltage sensor or oscilloscope.
  7. A rotary position sensor measures the angle of the shaft.

The voltage sensor records the induced emf, while the position sensor records the coil’s angle.

Both measurements can then be plotted against the same time axis.

What should the investigation show?

Start with the coil’s area normal aligned with the magnetic field.

The predicted emf is zero because magnetic flux is at an extremum.

As the motor turns the coil through \(90^\circ\), the flux decreases to zero and the emf reaches its positive maximum.

Another \(90^\circ\) rotation takes the coil to maximum negative flux, where the emf returns to zero.

The final quarter-turn produces maximum negative emf before the coil returns to its starting position.

For an illustrative idealised investigation with a peak emf of 10.0 V, the expected readings would be:

Coil angleExpected emf
\(0^\circ\)0 V
\(90^\circ\)+10.0 V
\(180^\circ\)0 V
\(270^\circ\)-10.0 V
\(360^\circ\)0 V

These are theoretical example values, not measurements from a real experiment.

The pattern supports Faraday’s law: the emf reaches its greatest magnitude when the magnetic flux is changing most rapidly, not when the flux itself is greatest.

Why is the position sensor important?

An initial arrangement with just a motor, rotating coil, and voltage sensor could show an alternating voltage.

However, it would be difficult to associate each voltage reading with an exact coil orientation.

Adding a rotary encoder solves this problem. It allows the angle and voltage measurements to be recorded together, so the relationship between position and emf can be examined directly.

The investigation also depends on keeping the magnetic field and coil area constant and controlling the rotation speed.

If the motor speeds up or slows down, the emf changes even when the coil reaches the same position. We’ll return to this important limitation in the final question.

05Slip rings versus split-ring commutators

Before sketching the final waveform, check which type of generator the question describes.

This matters because slip rings and split-ring commutators produce different external voltage waveforms.

AC generator: two continuous slip rings

An AC generator uses two separate, continuous slip rings.

Each end of the rotating coil connects to one ring. The stationary brushes maintain contact with the rings as they rotate.

The important detail is that each coil end stays connected to the same brush.

When the induced emf reverses direction after half a revolution, the external voltage also reverses.

Therefore, the output alternates between positive and negative values.

For an ideal generator:

\[ \mathcal E_{\text{out}}= \mathcal E_{\max}\sin\theta \]

This is the ordinary sinusoidal AC waveform.

DC generator: split-ring commutator

A split-ring commutator has two conducting semicircular segments separated by insulating gaps.

The coil ends connect to different segments. As the coil rotates, the segments exchange contact with the stationary brushes every half-turn.

This reverses the coil’s connections to the external circuit at the same time that the induced emf reverses.

The result is that the external voltage maintains the same polarity.

For an ideal generator with a suitable choice of output polarity:

\[ \mathcal E_{\text{out}}= \mathcal E_{\max}|\sin\theta| \]

The output is pulsating DC rather than AC.

Importantly, the emf induced inside the rotating coil still alternates. The commutator changes how that emf is connected to the external circuit.

FeatureSlip ringsSplit-ring commutator
Ring constructionTwo complete ringsTwo insulated semicircular segments
Connections to brushesEach coil end stays with the same brushCoil connections swap every half-turn
External polarityAlternatesRemains the same
OutputACPulsating DC
Ideal waveformSine waveRectified sine wave

A common exam mistake is to draw a positive-negative sine wave for a generator with a split-ring commutator. Always check the contact arrangement before drawing the output.

For a broader explanation of the generator’s operation, see AC Generators: Sinusoidal EMF and Slip Rings Explained.

For more detail on why the commutator changes the waveform, see How a Split-Ring Commutator Changes a Generator’s Waveform.

06Worked examples

Worked example: Finding emf from a known coil position

An ideal AC generator has a maximum induced emf of 18 V. The coil is rotating at constant angular speed, and its area normal has reached an angle of \(210^\circ\) with the magnetic field.

Calculate the instantaneous induced emf. Assume slip rings and a positive emf convention for increasing coil angle.

Step 1

For constant angular speed:

\[ \mathcal E=\mathcal E_{\max}\sin\theta \]

Step 2

\[ \mathcal E=18\sin210^\circ \]

Since:

\[ \sin210^\circ=-0.5 \]

we obtain:

\[ \mathcal E=18(-0.5) \]

\[ \boxed{\mathcal E=-9.0\text{ V}} \]

Step 3

The induced emf is \(-9.0\) V.

The negative sign indicates that the polarity is opposite to the chosen positive direction.

This makes sense because \(210^\circ\) is in the third quadrant of the rotation cycle, where the emf is negative.

The important skill here is recognising that the sign comes from the coil’s position and the chosen terminal convention, not simply from the size of the induced emf.

Worked example: Calculating peak and instantaneous emf

A generator contains an 80-turn rectangular coil. Each turn has an area of \(0.012\text{ m}^2\). The coil rotates in a uniform magnetic field of strength \(0.25\text{ T}\) at a frequency of 25 Hz.

At a particular instant, the area normal makes an angle of \(120^\circ\) with the magnetic field.

Calculate the instantaneous induced emf, assuming slip rings and increasing \(\theta\).

Step 1

The given frequency is 25 Hz, meaning the coil completes 25 revolutions per second.

Angular speed is:

\[ \omega=2\pi f \]

Substituting:

\[ \omega=2\pi(25) \]

\[ \omega=157.1\text{ rad s}^{-1} \]

Step 2

Use:

\[ \mathcal E_{\max}=NBA\omega \]

Substitute:

\[ \mathcal E_{\max} =(80)(0.25)(0.012)(157.1) \]

Therefore:

\[ \mathcal E_{\max}=37.7\text{ V} \]

Step 3

Use:

\[ \mathcal E=\mathcal E_{\max}\sin\theta \]

Substitute:

\[ \mathcal E=37.7\sin120^\circ \]

Since:

\[ \sin120^\circ=0.866 \]

we obtain:

\[ \boxed{\mathcal E=32.7\text{ V}} \]

Step 4

The instantaneous induced emf is \(+32.7\) V.

Although the coil is in the second quadrant, its emf is still positive. The polarity only reverses after the coil passes \(180^\circ\).

Notice that the calculation required both the coil’s position and its rotational speed. Position determines the sine factor, while the speed contributes to the maximum emf.

07Questions and solutions

Question 1

An ideal AC generator rotates at constant angular speed. Its maximum induced emf is 15 V.

The area normal initially points in the same direction as the magnetic field. The generator uses slip rings.

Determine the induced emf at each of the following positions:

  • \(0^\circ\)
  • \(90^\circ\)
  • \(180^\circ\)
  • \(270^\circ\)
  • \(360^\circ\)

Describe the waveform you would sketch.

Solution 1

The induced emf values are \(0\), \(+15\), \(0\), \(-15\), and \(0\) V, respectively.

Use:

\[ \mathcal E=15\sin\theta \]

Substituting each angle:

AngleCalculationEmf
\(0^\circ\)\(15\sin0^\circ\)0 V
\(90^\circ\)\(15\sin90^\circ\)+15 V
\(180^\circ\)\(15\sin180^\circ\)0 V
\(270^\circ\)\(15\sin270^\circ\)-15 V
\(360^\circ\)\(15\sin360^\circ\)0 V

The waveform starts at zero, rises to a positive maximum, returns to zero, falls to a negative maximum, and returns to zero.

Draw a smooth sine curve through these five points.

The important detail is that the maximum flux positions, \(0^\circ\) and \(180^\circ\), correspond to zero emf, not maximum emf.

Question 2

A 120-turn coil has an area of \(8.0\times10^{-3}\text{ m}^2\) and rotates in a uniform magnetic field of strength \(0.30\text{ T}\).

The generator rotates at 900 revolutions per minute.

At a particular instant, the area normal makes an angle of \(150^\circ\) with the magnetic field.

Calculate the instantaneous induced emf, assuming the coil rotates in the direction of increasing angle and is connected using slip rings.

Also explain why the magnetic flux and induced emf have opposite signs at this position.

Solution 2

The instantaneous induced emf is approximately \(+13.6\) V, even though the magnetic flux is negative.

Step 1: Convert rotational speed into frequency.

The coil rotates at 900 revolutions per minute.

\[ f=\frac{900}{60}=15\text{ Hz} \]

Step 2: Calculate angular speed.

\[ \omega=2\pi f \]

\[ \omega=2\pi(15) \]

\[ \omega=94.25\text{ rad s}^{-1} \]

Step 3: Calculate maximum emf.

\[ \mathcal E_{\max}=NBA\omega \]

Substituting:

\[ \mathcal E_{\max} =(120)(0.30)(0.008)(94.25) \]

\[ \mathcal E_{\max}=27.1\text{ V} \]

Step 4: Calculate instantaneous emf.

\[ \mathcal E=27.1\sin150^\circ \]

Since \(\sin150^\circ=0.5\):

\[ \boxed{\mathcal E=+13.6\text{ V}} \]

Step 5: Explain the signs.

Magnetic flux is:

\[ \Phi=BA\cos150^\circ \]

Because \(\cos150^\circ\) is negative, the flux is negative.

However, the emf depends on the rate of change of flux, not its actual value.

At \(150^\circ\), the flux is increasing towards its negative maximum as the coil continues rotating. The chosen positive emf convention therefore gives a positive induced emf.

This is an excellent example of why you should never determine the emf sign simply by looking at the sign of the magnetic flux.

Question 3

An ideal generator produces a maximum induced emf of 24 V.

The coil has rotated through \(225^\circ\), measured from its initial position where the area normal is parallel to the magnetic field.

Calculate the emf induced inside the coil.

Then determine the external output voltage if:

(a) The generator uses slip rings.

(b) The generator uses a split-ring commutator.

Explain why the two external readings are different even though the coil is in exactly the same position.

Solution 3

The emf inside the coil is approximately \(-17.0\) V. The slip-ring generator produces \(-17.0\) V externally, while the split-ring generator produces \(+17.0\) V externally.

Step 1: Calculate the induced emf inside the coil.

Use:

\[ \mathcal E=\mathcal E_{\max}\sin\theta \]

Substitute:

\[ \mathcal E=24\sin225^\circ \]

Since:

\[ \sin225^\circ=-0.7071 \]

we obtain:

\[ \boxed{\mathcal E=-17.0\text{ V}} \]

The coil’s induced emf is negative because it has passed \(180^\circ\) and entered the second half of its rotation cycle.

Step 2: Consider the slip-ring generator.

The slip rings maintain the same connection between each coil end and its external brush.

Therefore, the external polarity follows the induced emf inside the coil.

\[ \boxed{\mathcal E_{\text{slip}}=-17.0\text{ V}} \]

Step 3: Consider the split-ring generator.

The split-ring commutator reverses the external connections every half-turn.

The coil’s emf has reversed, but the external connections have also exchanged.

Consequently, the external polarity remains positive:

\[ \boxed{\mathcal E_{\text{split}}=+17.0\text{ V}} \]

Step 4: Explain the difference.

The magnetic field, coil area, rotation speed, and induced emf inside the coil are identical in both arrangements.

The difference comes from the electrical connections.

Slip rings preserve the original connections, allowing the external voltage to alternate.

A split-ring commutator swaps those connections every half-turn, producing a single-polarity output.

The commutator does not stop the coil from generating alternating emf. It changes how that emf appears in the external circuit.

Question 4

A student investigates a rotating coil generator. The coil rotates at constant angular speed, and the voltage sensor is connected across the brushes.

The data logger has been set to display the absolute value of voltage, rather than its signed value.

The following illustrative readings are recorded:

Coil angleDisplayed voltage
\(0^\circ\)0.1 V
\(90^\circ\)9.8 V
\(180^\circ\)0.2 V
\(270^\circ\)9.7 V
\(360^\circ\)0.1 V

The student concludes that the generator must use a split-ring commutator because the displayed voltage never becomes negative.

(a) Is the student’s conclusion justified?

(b) Explain how the readings relate to the coil’s orientation and the rate of change of magnetic flux.

(c) Describe what additional measurement would allow the student to distinguish between a slip-ring generator and a split-ring generator.

Solution 4

No, the student’s conclusion is not justified. Both arrangements could produce the displayed readings because the data logger removes the sign of the voltage.

Part (a): Identify the problem with the conclusion.

The sensor is displaying absolute voltage.

This means that both positive and negative readings are converted into positive values.

For example:

\[ |+9.8|=9.8 \]

and:

\[ |-9.8|=9.8 \]

A slip-ring generator can therefore produce the same displayed magnitudes as a split-ring generator.

The fact that every reading is positive does not prove that the physical generator produces a single-polarity output.

Part (b): Interpret the readings.

At \(0^\circ\), the magnetic flux is at its maximum positive value, so the induced emf should be zero.

At \(90^\circ\), magnetic flux is changing most rapidly, so the induced emf reaches its maximum magnitude.

At \(180^\circ\), flux reaches its maximum negative value and the emf returns to zero.

At \(270^\circ\), flux changes most rapidly in the opposite direction, producing another maximum emf, but with reversed polarity for a slip-ring generator.

The readings are consistent with this predicted sequence.

The small non-zero readings at the expected zero crossings could result from sensor offset, electrical noise, or measurement uncertainty.

Part (c): Identify the additional measurement.

The student should record the signed voltage across the brushes using a voltage sensor or oscilloscope that preserves polarity.

With slip rings, the readings should alternate between positive and negative values.

With a split-ring commutator, the external voltage should retain the same polarity.

Inspecting the actual ring arrangement would also distinguish the two systems.

The key experimental lesson is that a measurement instrument can hide information if its display settings remove the sign.

Question 5

An ideal one-turn generator coil rotates in a uniform magnetic field. Its magnetic and geometric properties give:

\[ NBA=0.40\text{ V s} \]

The coil is initially positioned with its area normal parallel to the magnetic field.

The generator uses slip rings, and the positive emf convention is defined for increasing rotation angle.

During its first complete revolution, the coil rotates at a constant angular speed of \(5\text{ rad s}^{-1}\).

At exactly \(360^\circ\), the motor setting changes, and the coil rotates at a constant angular speed of \(10\text{ rad s}^{-1}\) for its second complete revolution.

Assume an idealised instantaneous speed change at \(360^\circ\), where the induced emf is zero. Ignore acceleration effects.

A student makes the following argument:

The coil returns to exactly the same positions during the second revolution. Therefore, the emf at each position must be identical to the emf during the first revolution. The two graphs should overlap.

Another student argues:

The second revolution is twice as fast, so its waveform should be twice as high and twice as wide.

Both students are partly wrong.

(a) Calculate the maximum emf during each revolution.

(b) Calculate the induced emf at \(60^\circ\) during each revolution.

(c) Explain what happens to the emf at \(240^\circ\) during each revolution.

(d) Compare the two waveforms when plotted against coil angle and when plotted against time.

(e) If the slip rings are replaced with a split-ring commutator, explain which features of the two waveforms change and which remain unchanged.

Solution 5

The second revolution produces twice the maximum emf, despite having exactly the same coil orientations as the first revolution. Its waveform is twice as high but has half the period when plotted against time. The split-ring commutator changes the polarity of the external output, but does not remove the effect of rotational speed.

This question tests an important limitation of using coil position alone to predict emf: the position determines the magnetic flux, but the speed determines how rapidly that flux changes.

Part (a): Calculate the maximum emf during each revolution.

Use:

\[ \mathcal E_{\max}=NBA\omega \]

For the first revolution:

\[ \mathcal E_{\max,1} =(0.40)(5) \]

\[ \boxed{\mathcal E_{\max,1}=2.0\text{ V}} \]

For the second revolution:

\[ \mathcal E_{\max,2} =(0.40)(10) \]

\[ \boxed{\mathcal E_{\max,2}=4.0\text{ V}} \]

Doubling the angular speed doubles the maximum rate of change of magnetic flux.

Therefore, the maximum induced emf also doubles.

Part (b): Calculate emf at \(60^\circ\).

Use:

\[ \mathcal E=NBA\omega\sin\theta \]

For the first revolution:

\[ \mathcal E_1 =(0.40)(5)\sin60^\circ \]

\[ \mathcal E_1=2.0(0.866) \]

\[ \boxed{\mathcal E_1=+1.73\text{ V}} \]

For the second revolution:

\[ \mathcal E_2 =(0.40)(10)\sin60^\circ \]

\[ \mathcal E_2=4.0(0.866) \]

\[ \boxed{\mathcal E_2=+3.46\text{ V}} \]

The second emf is twice as large.

The coil has exactly the same orientation in both cases, so its magnetic flux is identical. However, it moves through that orientation twice as quickly during the second revolution.

That is why the induced emf is different.

Part (c): Consider the position \(240^\circ\).

At \(240^\circ\):

\[ \sin240^\circ=-0.866 \]

For the first revolution:

\[ \mathcal E_1 =2.0(-0.866) \]

\[ \boxed{\mathcal E_1=-1.73\text{ V}} \]

For the second revolution:

\[ \mathcal E_2 =4.0(-0.866) \]

\[ \boxed{\mathcal E_2=-3.46\text{ V}} \]

Both values are negative because the coil is in the second half of its rotation cycle.

Their magnitudes differ because the rotational speeds differ.

This is another demonstration that the same coil position does not guarantee the same induced emf.

Part (d): Compare the graphs.

First, consider a graph of emf against coil angle.

Both revolutions have the same zero crossings:

\[ 0^\circ,\quad180^\circ,\quad360^\circ \]

Both also have their positive and negative peaks at:

\[ 90^\circ,\quad270^\circ \]

However, the second revolution has twice the amplitude.

The two curves therefore do not overlap. The second is twice as high, while the angular spacing of its peaks and zero crossings is unchanged.

Now consider emf against time.

The period of rotation is:

\[ T=\frac{2\pi}{\omega} \]

For the first revolution:

\[ T_1=\frac{2\pi}{5} \]

\[ \boxed{T_1=1.26\text{ s}} \]

For the second revolution:

\[ T_2=\frac{2\pi}{10} \]

\[ \boxed{T_2=0.628\text{ s}} \]

The second revolution takes half as long.

Therefore, the second waveform is twice as high and half as wide on a time axis.

The second student’s mistake was saying the waveform becomes twice as wide. Doubling angular speed compresses the cycle horizontally when time is on the horizontal axis.

Because the speed changes between revolutions, the complete output is not one repeating sine wave with a single fixed amplitude and period. Each revolution has its own amplitude and period.

Part (e): Replace the slip rings with a split-ring commutator.

The split-ring commutator reverses the external connections every half-turn.

Consequently, the negative half of each revolution is reflected above the horizontal axis.

For an ideal generator:

\[ \mathcal E_{\text{out}} =NBA\omega|\sin\theta| \]

The first revolution now produces positive pulses with a maximum of \(2.0\) V.

The second produces positive pulses with a maximum of \(4.0\) V.

The following features remain unchanged:

  • The coil’s magnetic flux at each angular position.
  • The magnitude of the emf at a given speed and coil position.
  • The effect of doubling angular speed.
  • The angular positions at which the induced emf is zero.

The feature that changes is the external polarity: the split-ring commutator makes both half-cycles positive.

The speed change still doubles the peak output and halves the time period of the second revolution.

One final physical qualification: a real motor cannot change speed instantaneously. It accelerates over a finite interval, so the transition between the two waveforms would be smooth rather than an abrupt change in amplitude and frequency.

The central lesson is that coil geometry determines magnetic flux, rotational speed determines its rate of change, and the ring arrangement determines the polarity of the external output.

08What to remember when sketching an AC generator waveform

When an HSC Physics question asks you to sketch induced emf from coil position, use this sequence:

  1. Identify the area normal and measure its angle relative to the magnetic field.
  2. Determine the magnetic flux using \(\Phi=BA\cos\theta\).
  3. Remember that emf depends on the rate of change of flux, not the flux itself.
  4. Mark zero emf at \(0^\circ\), \(180^\circ\), and \(360^\circ\).
  5. Mark maximum positive emf at \(90^\circ\) and maximum negative emf at \(270^\circ\), using the stated sign convention.
  6. Check whether the generator uses slip rings or a split-ring commutator.
  7. If the horizontal axis is time, account for the rotational speed and period.

The next useful step is learning to sketch magnetic flux and induced emf on the same set of axes. Once you can recognise the gradient of the flux graph, you can predict the entire emf waveform without memorising individual coil positions.