Laser Linewidth: Spectral Width, Coherence, and Cavity Modes
Explore why laser light has a finite spectral width, how optical cavities select resonant frequencies, and why linewidth determines temporal coherence. Includes worked examples connecting cavity properties, frequency stability, and coherence length.
A red laser pointer looks as though it emits light at one perfectly defined frequency. But if you examine its output with a sufficiently precise optical instrument, you will not find a single, infinitely thin spectral line. You will find a narrow peak with a small but measurable width.
Why isn’t laser light perfectly monochromatic? And what does this tiny frequency variation have to do with the ability of light waves to maintain a predictable phase relationship?
The answer involves a property called laser linewidth, which connects the frequency spectrum of a laser to its coherence and the physical properties of the optical cavity that produces its light.
Scope note: Laser linewidth is an extension beyond the required Year 12 Nature of light syllabus content. The Year 12 material provides the prerequisite knowledge, not an additional HSC assessment requirement. The NSW Physics 11-12 Syllabus (2025) begins implementation in 2027; Year 12 students in 2026 continue under the 2017 syllabus. See the official NESA implementation information.
01From electromagnetic waves to laser light
Before considering linewidth, it helps to revisit how light is produced and propagated.
How electromagnetic waves are produced
In the classical electromagnetic model, accelerating electric charges produce electromagnetic radiation.
Consider an antenna connected to an alternating current supply. Electrons move back and forth along the antenna, repeatedly accelerating and changing direction. This produces changing electric and magnetic fields that propagate away from the antenna.
The resulting electromagnetic wave has three important features:
- Its electric field, \(E\), oscillates perpendicular to its magnetic field, \(B\).
- Both fields are perpendicular to the direction of propagation.
- In a vacuum, the wave travels at the speed of light, \(c\), approximately \(3.00\times10^8\ \mathrm{m\,s^{-1}}\).
The changing electric and magnetic fields are linked through Maxwell’s equations, allowing the electromagnetic disturbance to propagate without requiring a material medium.
The familiar wave relationship is
\[ c=f\lambda \]
where:
- \(c\) is the speed of light in a vacuum, in \(\mathrm{m\,s^{-1}}\).
- \(f\) is the frequency, in hertz (Hz).
- \(\lambda\) is the wavelength, in metres (m).
A laser also produces electromagnetic radiation, but its microscopic emission mechanism is different from that of an antenna.
What makes a laser different?
A laser uses a process called stimulated emission.
The central component is a gain medium: a material containing atoms, ions, or other particles that can occupy different energy states.
Energy is supplied to this material through a process called pumping. This creates a population inversion, where more particles occupy the relevant excited energy state than the lower energy state.
Now imagine a photon travelling through the gain medium.
If it interacts with a particle in the appropriate excited state, it can stimulate that particle to transition to a lower energy state. The transition releases another photon.
In the idealised description, the emitted photon joins the stimulating light in the same optical mode. It has the same frequency, direction, polarisation, and phase relationship.
The process can repeat as the light travels through the gain medium, amplifying the electromagnetic field.
This is the origin of the name:
Light Amplification by Stimulated Emission of Radiation.
The energy difference between the two states determines the photon frequency:
\[ \Delta E=hf \]
where \(h\) is Planck’s constant and \(\Delta E\) is the energy difference between the states.
The important idea is that stimulated emission reinforces an existing electromagnetic field rather than simply producing unrelated light.
The optical cavity
Most lasers also use an optical cavity to provide feedback.
A simple linear optical cavity consists of two mirrors facing each other, with the gain medium between them.
- One mirror reflects almost all the incident light.
- The other mirror is partially transmitting, allowing some light to escape as the laser output.
Light travels back and forth through the gain medium, undergoing repeated amplification.
Think of the cavity as a room that naturally reinforces certain sound frequencies. Other frequencies do not produce the same reinforcing pattern.
The analogy is useful because it highlights resonance, but the laser cavity supports electromagnetic standing-wave modes rather than sound waves in air.
Only certain frequencies satisfy the cavity’s resonance condition.
This is where linewidth becomes interesting.
02The cavity does not support every frequency equally
For a simple linear cavity, light must travel a round-trip distance and return with a phase that reinforces the existing field.
This requires the round-trip optical path length to contain an integer number of wavelengths.
The resonance condition is
\[ 2nL=m\lambda_0 \]
where:
- \(L\) is the distance between the mirrors, in metres.
- \(n\) is the refractive index inside the cavity.
- \(m\) is a positive integer called the longitudinal mode number.
- \(\lambda_0\) is the wavelength in a vacuum, in metres.
Since \(c=f\lambda_0\), the allowed resonant frequencies are
\[ \nu_m=\frac{mc}{2nL} \]
Here, \(\nu_m\) is the frequency of longitudinal mode \(m\).
The cavity therefore supports a series of discrete resonant frequencies rather than every possible frequency.
Free spectral range
The frequency difference between two adjacent longitudinal modes is called the free spectral range (FSR).
Subtracting the frequencies of adjacent modes gives
\[ \boxed{\Delta\nu_{\mathrm{FSR}}=\frac{c}{2nL}} \]
This equation reveals two useful relationships:
- Increasing the cavity length decreases the separation between adjacent modes.
- Increasing the refractive index also decreases their separation, assuming the cavity geometry remains unchanged.
The formula assumes a uniform, non-dispersive medium and a linear two-mirror cavity. More advanced treatments account for dispersion using the group refractive index.
Gain bandwidth versus laser linewidth
There are two different frequency ranges to consider.
The first is the gain bandwidth.
The gain medium can amplify light across a range of frequencies. This range depends on the properties of the material and its energy transitions.
The second is the laser linewidth.
The cavity favours particular resonant frequencies within the gain bandwidth. If one longitudinal mode dominates, the output spectrum contains a narrow peak around that mode’s central frequency.
If several modes have sufficient gain to overcome cavity losses, multiple peaks may appear.
This gives us an important distinction:
The gain bandwidth determines the range of frequencies that can be amplified. The cavity selects resonant modes within that range. The linewidth describes the finite width of an individual emitted spectral line.
A laser can therefore have a gain medium with a relatively broad amplification range while producing a very narrow output line.
This is quite different from the broad distribution of frequencies emitted by a thermal source. For comparison, see The Planck Radiation Law: Understanding Black-Body Spectra.
03What is laser linewidth?
An ideal monochromatic wave has one perfectly defined frequency.
Its spectrum would be represented by a single infinitely narrow peak.
Real laser light does not behave this way.
Even when a laser operates in a single longitudinal mode, its emitted frequency fluctuates slightly over time. The result is a spectral peak with a finite width.
This width is called the laser linewidth.
It is commonly measured using the full width at half maximum (FWHM) of the spectral peak.
Imagine measuring the spectral power of a laser at different frequencies.
At the central frequency, the spectral peak reaches its maximum value. Move away from this frequency, and the spectral power decreases.
The linewidth is the frequency interval between the two points where the spectral power has fallen to half its maximum value.
It is represented by
\[ \Delta\nu \]
and measured in hertz.
A smaller linewidth means the light is concentrated within a narrower frequency range.
A larger linewidth means the frequency distribution is broader.
But why does a laser have any linewidth at all?
Why a laser cannot maintain a perfectly fixed phase
There are two important contributions to the finite linewidth.
1. Spontaneous emission
Stimulated emission reinforces the existing laser field, but spontaneous emission can also occur within the gain medium.
Spontaneously emitted photons that enter the lasing mode introduce small fluctuations into the electromagnetic field.
These fluctuations can disturb its phase.
Think of the phase as the position of a clock hand. Each spontaneous emission event can introduce a small, unpredictable change. Over many events, these changes accumulate.
The phase gradually becomes less predictable.
This behaviour is often described as phase diffusion.
The laser therefore cannot maintain a perfectly predictable phase indefinitely, even if its average frequency is extremely stable.
The fundamental quantum contribution to this effect is associated with the Schawlow-Townes linewidth, named after the physicists Arthur Schawlow and Charles Townes.
Their work established an important theoretical limit on the spectral purity of laser radiation. The simplest model assumes an idealised laser, and more detailed treatments account for additional physical effects.
For a more advanced explanation, see Cambridge University’s discussion of the Schawlow-Townes linewidth.
2. Technical fluctuations
Real laser cavities are also affected by their surroundings.
For example:
- Mechanical vibrations can change the distance between the mirrors.
- Temperature changes can expand or contract cavity components.
- Temperature-dependent refractive index changes can alter the optical path length.
- Fluctuations in the pumping system can affect the gain medium.
These effects can cause the laser’s central frequency to drift.
The distinction matters because spontaneous emission produces an intrinsic contribution to linewidth, while technical fluctuations can broaden the measured spectrum further.
A laser can have an extremely narrow intrinsic linewidth but still show poor frequency stability if its cavity is sensitive to its surroundings.
A crucial distinction: cavity linewidth is not laser linewidth
A cavity itself has a finite resonance width.
This occurs because its mirrors are not perfectly reflecting. Some light escapes, while absorption and scattering introduce further losses.
The width of a passive cavity resonance is represented here by
\[ \delta\nu_{\mathrm{cav}} \]
This is different from the linewidth of the laser’s emitted light.
A useful measure of cavity performance is its finesse:
\[ \boxed{ \mathcal{F} = \frac{\Delta\nu_{\mathrm{FSR}}} {\delta\nu_{\mathrm{cav}}} } \]
where:
- \(\mathcal{F}\) is the dimensionless cavity finesse.
- \(\Delta\nu_{\mathrm{FSR}}\) is the free spectral range.
- \(\delta\nu_{\mathrm{cav}}\) is the FWHM of a passive cavity resonance.
A higher finesse means the cavity resonances are narrower relative to their spacing.
This generally occurs when the mirrors have higher reflectivity and the cavity has lower internal losses.
The light is stored in the cavity for longer before escaping, producing sharper resonances.
A high-finesse cavity can help select and stabilise a narrow laser frequency. However, its passive resonance width is not automatically the linewidth of the laser output.
In fact, the fundamental linewidth of a laser can be much narrower than the passive cavity resonance width.
The actual output linewidth also depends on spontaneous emission, optical power, cavity stability, and other sources of noise.
Here is a useful comparison:
| Property | What it describes | Main influences |
|---|---|---|
| Gain bandwidth | Range of frequencies the medium can amplify | Gain medium and its energy transitions |
| Free spectral range | Spacing between adjacent cavity modes | Cavity optical length |
| Cavity resonance linewidth | Width of a passive cavity resonance | Mirror reflectivity and cavity losses |
| Laser linewidth | Width of an emitted laser spectral line | Phase noise, spontaneous emission, and technical fluctuations |
Keeping these four quantities separate prevents many errors when analysing laser spectra.
04Laser linewidth and coherence
Now we can connect linewidth to one of the most important properties of laser light: coherence.
What is temporal coherence?
Temporal coherence describes how well the phase of a light wave at one time is related to its phase at a later time.
Imagine splitting a laser beam into two paths.
One path is slightly longer than the other. When the two beams recombine, they interfere.
If their phase relationship remains predictable, a stable interference pattern can form.
However, if the delay becomes sufficiently large, fluctuations in the laser’s phase reduce the visibility of the interference pattern.
The time over which the phase relationship remains significantly predictable is described by the coherence time.
We represent it as
\[ \tau_{\mathrm{coh}} \]
A longer coherence time means the laser maintains a predictable phase relationship over a longer time interval.
A shorter coherence time means its phase becomes unpredictable more quickly.
The mathematical connection
For a laser with an ideal Lorentzian spectral line, the relationship between linewidth and coherence time is
\[ \boxed{ \tau_{\mathrm{coh}}=\frac{1}{\pi\Delta\nu} } \]
Here:
- \(\tau_{\mathrm{coh}}\) is the coherence time, in seconds.
- \(\Delta\nu\) is the laser linewidth (FWHM), in hertz.
- \(\pi\) is the mathematical constant approximately equal to 3.1416.
This expression uses a particular convention: coherence time is the delay at which the magnitude of the normalised field correlation has fallen to \(1/e\) of its initial value.
For the Lorentzian model, the correlation decreases according to
\[ |g^{(1)}(\tau)| = e^{-\pi\Delta\nu|\tau|} \]
where \(g^{(1)}(\tau)\) is the normalised first-order temporal field correlation and \(\tau\) is the time delay.
You do not need to derive this expression using Fourier transforms to understand the physical relationship.
The key result is:
\[ \boxed{ \text{Narrower linewidth} \Longrightarrow \text{Longer coherence time} } \]
If the linewidth is halved, the coherence time doubles, provided the same Lorentzian model and definition are used.
This is the prediction we made at the beginning.
Coherence length
We can convert coherence time into a distance.
Light travels at speed \(c\) in a vacuum. Therefore, the distance travelled during one coherence time is
\[ \boxed{ L_{\mathrm{coh}}=c\tau_{\mathrm{coh}} } \]
where \(L_{\mathrm{coh}}\) is the coherence length, measured in metres.
Combining the two equations gives
\[ L_{\mathrm{coh}}=\frac{c}{\pi\Delta\nu} \]
This tells us approximately how far light can travel while maintaining a predictable temporal phase relationship, under the stated Lorentzian convention.
In a material medium, the relevant propagation speed must replace \(c\).
Importantly, coherence length is not a sharp boundary beyond which interference suddenly becomes impossible. Interference visibility decreases gradually.
Also, this is a measure of temporal coherence, not spatial coherence. The two describe different aspects of a light field.
Does the spectral line shape matter?
Yes.
The equation \(\tau_{\mathrm{coh}}=1/(\pi\Delta\nu)\) applies to the Lorentzian model with the specified coherence-time convention.
Real lasers do not always have perfectly Lorentzian spectra.
For example:
- White frequency noise and phase diffusion can produce a Lorentzian spectral line.
- Slow frequency fluctuations can introduce Gaussian-like broadening.
- A combination of noise sources can produce a more complicated profile, such as a Voigt line shape.
Therefore, linewidth alone does not always provide a complete description of coherence.
The assumed line shape and measurement timescale matter.
For a detailed discussion of this relationship, see RP Photonics Encyclopedia, article on “Coherence Time”, Dr. Rüdiger Paschotta, https://www.rp-photonics.com/coherence_time.html.
05Converting linewidth between frequency and wavelength
Laser linewidth is often expressed in frequency units, but some optical measurements report it in wavelength units.
The two quantities are connected by
\[ \nu=\frac{c}{\lambda} \]
For a sufficiently narrow spectral line, we can use a small-change approximation:
\[ \boxed{ \Delta\lambda \approx \frac{\lambda_0^2}{c}\Delta\nu } \]
where:
- \(\lambda_0\) is the central vacuum wavelength.
- \(\Delta\lambda\) is the wavelength linewidth.
- \(\Delta\nu\) is the frequency linewidth.
- \(c\) is the speed of light in a vacuum.
This approximation assumes that the linewidth is very small compared with the central frequency and wavelength.
Notice that the relationship is not linear in the central wavelength: the wavelength linewidth depends on \(\lambda_0^2\).
This is useful when interpreting optical spectra, particularly when comparing lasers that operate at different wavelengths.
06Worked example: Converting a laser’s frequency linewidth into wavelength linewidth
A single-mode laser emits light with a central vacuum wavelength of \(532\ \mathrm{nm}\). Its measured Lorentzian frequency linewidth is \(1.5\ \mathrm{MHz}\).
Calculate its wavelength linewidth.
Step 1
For a narrow spectral line,
\[ \Delta\lambda \approx \frac{\lambda_0^2}{c}\Delta\nu \]
Step 2
\[ \lambda_0=532\times10^{-9}\ \mathrm{m} \]
\[ \Delta\nu=1.5\times10^6\ \mathrm{Hz} \]
Step 3
\[ \Delta\lambda = \frac{(532\times10^{-9})^2} {3.00\times10^8} (1.5\times10^6) \]
\[ \Delta\lambda \approx1.42\times10^{-15}\ \mathrm{m} \]
Converting to nanometres:
\[ \Delta\lambda \approx1.42\times10^{-6}\ \mathrm{nm} \]
Final answer: The wavelength linewidth is approximately \(1.42\times10^{-6}\ \mathrm{nm}\).
The result is extremely small compared with the central wavelength of \(532\ \mathrm{nm}\).
This is why laser light is often treated as monochromatic in introductory physics. The approximation is useful, even though the actual spectral width is not zero.
07Worked example: Calculating cavity properties and coherence length
A laser operates inside a linear optical cavity with a mirror separation of \(0.30\ \mathrm{m}\). The cavity contains air, which we approximate as having a refractive index of \(n=1.00\).
The cavity has a finesse of 300.
The laser operates in a single longitudinal mode, with a measured Lorentzian output linewidth of \(20\ \mathrm{kHz}\).
Calculate:
- The free spectral range.
- The passive cavity resonance linewidth.
- The laser’s coherence time.
- The laser’s coherence length.
Step 1
For a linear cavity,
\[ \Delta\nu_{\mathrm{FSR}}=\frac{c}{2nL} \]
Substitute:
\[ \Delta\nu_{\mathrm{FSR}} = \frac{3.00\times10^8} {2(1.00)(0.30)} \]
\[ \Delta\nu_{\mathrm{FSR}} =5.00\times10^8\ \mathrm{Hz} \]
Therefore,
\[ \boxed{\Delta\nu_{\mathrm{FSR}}=500\ \mathrm{MHz}} \]
Adjacent longitudinal cavity modes are separated by \(500\ \mathrm{MHz}\).
Step 2
The finesse is
\[ \mathcal{F} = \frac{\Delta\nu_{\mathrm{FSR}}} {\delta\nu_{\mathrm{cav}}} \]
Rearranging:
\[ \delta\nu_{\mathrm{cav}} = \frac{\Delta\nu_{\mathrm{FSR}}}{\mathcal{F}} \]
Substituting:
\[ \delta\nu_{\mathrm{cav}} = \frac{500\times10^6}{300} \]
\[ \boxed{ \delta\nu_{\mathrm{cav}} =1.67\times10^6\ \mathrm{Hz} } \]
The passive cavity resonance has a FWHM of approximately \(1.67\ \mathrm{MHz}\).
Step 3
We are given the actual laser output linewidth:
\[ \Delta\nu=20\times10^3\ \mathrm{Hz} \]
Using the Lorentzian relationship:
\[ \tau_{\mathrm{coh}} = \frac{1}{\pi\Delta\nu} \]
\[ \tau_{\mathrm{coh}} = \frac{1}{\pi(20\times10^3)} \]
\[ \boxed{ \tau_{\mathrm{coh}} =1.59\times10^{-5}\ \mathrm{s} } \]
The coherence time is approximately \(15.9\ \mathrm{\mu s}\).
Step 4
\[ L_{\mathrm{coh}}=c\tau_{\mathrm{coh}} \]
\[ L_{\mathrm{coh}} = (3.00\times10^8) (1.59\times10^{-5}) \]
\[ \boxed{ L_{\mathrm{coh}}\approx4.77\times10^3\ \mathrm{m} } \]
The coherence length is approximately \(4.77\ \mathrm{km}\).
Final interpretation: The laser’s output linewidth is approximately 83 times narrower than the passive cavity resonance linewidth.
This is not a contradiction. The passive cavity resonance width and the linewidth of the actively operating laser describe different properties.
The laser’s narrow output line also gives it a relatively long coherence time and coherence length.
08Questions and solutions
Question 1
A single-mode laser produces a Lorentzian spectral line with a FWHM linewidth of \(250\ \mathrm{kHz}\).
Calculate:
(a) Its coherence time.
(b) Its coherence length in air, assuming the speed of light is \(3.00\times10^8\ \mathrm{m\,s^{-1}}\).
Use the convention that coherence time corresponds to a \(1/e\) decrease in the magnitude of the field correlation.
Solution 1
The coherence time is approximately \(1.27\ \mathrm{\mu s}\), and the coherence length is approximately \(382\ \mathrm{m}\).
Step 1: Calculate the coherence time.
For a Lorentzian spectral line,
\[ \tau_{\mathrm{coh}}=\frac{1}{\pi\Delta\nu} \]
Substitute:
\[ \tau_{\mathrm{coh}} = \frac{1}{\pi(250\times10^3)} \]
\[ \boxed{ \tau_{\mathrm{coh}}=1.27\times10^{-6}\ \mathrm{s} } \]
Step 2: Calculate the coherence length.
\[ L_{\mathrm{coh}}=c\tau_{\mathrm{coh}} \]
\[ L_{\mathrm{coh}} = (3.00\times10^8) (1.27\times10^{-6}) \]
\[ \boxed{ L_{\mathrm{coh}}\approx382\ \mathrm{m} } \]
The laser maintains a predictable temporal phase relationship over a characteristic propagation distance of approximately \(382\ \mathrm{m}\).
This does not mean interference becomes impossible immediately after that distance. The interference visibility decreases continuously.
Question 2
A linear laser cavity has a mirror separation of \(0.25\ \mathrm{m}\) and contains air with refractive index \(n=1.00\).
Its finesse is 200.
The gain curve has a FWHM bandwidth of \(2.0\ \mathrm{GHz}\), centred exactly on one cavity resonance.
For this question, assume that every longitudinal resonance inside the gain FWHM has sufficient net gain to lase, while every resonance outside it does not.
Calculate:
(a) The free spectral range.
(b) The passive cavity resonance linewidth.
(c) The number of longitudinal modes that can lase.
Explain why the cavity resonance linewidth is not the same as the spacing between longitudinal modes.
Solution 2
The free spectral range is \(600\ \mathrm{MHz}\), the passive cavity resonance linewidth is \(3.0\ \mathrm{MHz}\), and three longitudinal modes can lase under the stated assumptions.
Step 1: Calculate the free spectral range.
\[ \Delta\nu_{\mathrm{FSR}}=\frac{c}{2nL} \]
Substitute:
\[ \Delta\nu_{\mathrm{FSR}} = \frac{3.00\times10^8} {2(1.00)(0.25)} \]
\[ \boxed{ \Delta\nu_{\mathrm{FSR}}=600\ \mathrm{MHz} } \]
Step 2: Calculate the passive cavity resonance linewidth.
\[ \mathcal{F} = \frac{\Delta\nu_{\mathrm{FSR}}} {\delta\nu_{\mathrm{cav}}} \]
Rearranging:
\[ \delta\nu_{\mathrm{cav}} = \frac{600\ \mathrm{MHz}}{200} \]
\[ \boxed{ \delta\nu_{\mathrm{cav}}=3.0\ \mathrm{MHz} } \]
Step 3: Determine how many longitudinal modes fall within the gain bandwidth.
The gain curve has a total FWHM of \(2.0\ \mathrm{GHz}\).
Since it is centred on a cavity resonance, the frequency range extends \(1.0\ \mathrm{GHz}\) on either side of that central resonance.
The adjacent cavity modes are separated by \(600\ \mathrm{MHz}\).
Therefore, the modes occur at offsets of:
- \(0\ \mathrm{MHz}\)
- \(+600\ \mathrm{MHz}\)
- \(-600\ \mathrm{MHz}\)
- \(+1200\ \mathrm{MHz}\)
- \(-1200\ \mathrm{MHz}\)
Only the first three lie inside the gain FWHM.
Thus,
\[ \boxed{3\text{ longitudinal modes}} \]
can lase under the assumptions in the question.
Step 4: Explain the distinction between mode spacing and resonance linewidth.
The free spectral range describes the separation between the centres of adjacent longitudinal modes.
The cavity resonance linewidth describes the width of each individual passive resonance.
Here, the modes are separated by \(600\ \mathrm{MHz}\), but each cavity resonance is only \(3.0\ \mathrm{MHz}\) wide.
These are different measurements.
The distinction is important because a cavity can support many closely spaced resonant modes while each individual resonance remains very narrow.
In an actual laser, whether a mode reaches threshold depends on the frequency-dependent gain and losses, not simply whether it lies inside the gain FWHM. The threshold rule in this question is an intentional simplification.
Question 3
A linear laser cavity operates in air. Its length is initially \(0.20\ \mathrm{m}\), and one of its longitudinal modes has a central vacuum wavelength of \(500\ \mathrm{nm}\).
The cavity length increases by \(40\ \mathrm{nm}\), while the longitudinal mode number remains fixed.
Assume the refractive index does not change.
(a) Calculate the fractional change in the mode’s resonant frequency.
(b) Calculate the approximate absolute frequency shift.
(c) Explain whether this change represents an increase in linewidth or a shift in the central frequency.
Solution 3
The resonant frequency decreases by approximately \(120\ \mathrm{MHz}\). This is a shift in the central frequency, not automatically an increase in linewidth.
Step 1: Relate frequency to cavity length.
For a fixed longitudinal mode number,
\[ \nu_m=\frac{mc}{2nL} \]
Since \(m\), \(c\), and \(n\) remain constant,
\[ \nu_m\propto\frac{1}{L} \]
For a small change in cavity length,
\[ \frac{\Delta\nu}{\nu} \approx -\frac{\Delta L}{L} \]
The negative sign indicates that increasing cavity length decreases resonant frequency.
Step 2: Calculate the fractional frequency change.
Convert the change in length:
\[ \Delta L=40\times10^{-9}\ \mathrm{m} \]
Substitute:
\[ \frac{\Delta\nu}{\nu} = -\frac{40\times10^{-9}}{0.20} \]
\[ \boxed{ \frac{\Delta\nu}{\nu} =-2.0\times10^{-7} } \]
Step 3: Calculate the original frequency.
Using
\[ \nu=\frac{c}{\lambda} \]
\[ \nu= \frac{3.00\times10^8} {500\times10^{-9}} \]
\[ \nu=6.00\times10^{14}\ \mathrm{Hz} \]
Step 4: Calculate the absolute frequency shift.
\[ \Delta\nu = \nu\left(\frac{\Delta\nu}{\nu}\right) \]
\[ \Delta\nu = (6.00\times10^{14}) (-2.0\times10^{-7}) \]
\[ \boxed{ \Delta\nu=-1.20\times10^8\ \mathrm{Hz} } \]
The resonant frequency decreases by \(120\ \mathrm{MHz}\).
Step 5: Interpret the result.
The cavity length has changed, shifting the frequency at which the original longitudinal mode resonates.
This is a change in the line’s central frequency, not necessarily a change in its linewidth.
However, consider what happens if the cavity length keeps fluctuating during a long measurement.
The resonant frequency will continually move. A spectrum recorded over that period may show a broader peak because it combines light emitted at slightly different central frequencies.
This is one way technical instability can increase the measured linewidth.
Question 4
A diode laser is measured using an optical spectrum analyser.
During short \(1\ \mathrm{ms}\) measurements, it produces a stable Lorentzian spectral line with a FWHM of \(30\ \mathrm{kHz}\).
However, during a longer \(10\ \mathrm{s}\) recording, temperature changes inside the cavity cause the central frequency to drift. The time-averaged spectrum now has a width of \(0.42\ \mathrm{MHz}\).
(a) Calculate the coherence time associated with the short-term linewidth.
(b) A student substitutes the long-term width into the Lorentzian coherence-time equation and claims that the laser’s intrinsic coherence time has decreased to approximately \(0.76\ \mathrm{\mu s}\).
Explain why this conclusion is not necessarily correct.
Solution 4
The short-term coherence time is approximately \(10.6\ \mathrm{\mu s}\). The student’s long-term calculation does not necessarily represent the intrinsic coherence time because the measured width includes slow frequency drift.
Step 1: Calculate the short-term coherence time.
The short-term spectrum is Lorentzian, so we can use
\[ \tau_{\mathrm{coh}}=\frac{1}{\pi\Delta\nu} \]
Substitute:
\[ \tau_{\mathrm{coh}} = \frac{1}{\pi(30\times10^3)} \]
\[ \boxed{ \tau_{\mathrm{coh}} =1.06\times10^{-5}\ \mathrm{s} } \]
Therefore,
\[ \boxed{ \tau_{\mathrm{coh}}=10.6\ \mathrm{\mu s} } \]
Step 2: Examine the student’s long-term calculation.
The long-term measured width is
\[ \Delta\nu=0.42\ \mathrm{MHz} \]
If we mechanically apply the Lorentzian equation,
\[ \tau_{\mathrm{coh}} = \frac{1}{\pi(0.42\times10^6)} \]
\[ \tau_{\mathrm{coh}} \approx0.758\ \mathrm{\mu s} \]
The arithmetic is correct.
The physical interpretation is the problem.
Step 3: Identify what has broadened the measured spectrum.
The laser has a short-term linewidth of \(30\ \mathrm{kHz}\).
Over a longer recording, however, the cavity temperature changes. This alters its optical length and causes the central frequency to drift.
The spectrum analyser combines measurements taken at different central frequencies.
Consequently, the time-averaged spectrum is wider than the individual short-term spectra.
The additional width is associated with technical frequency instability rather than necessarily representing the intrinsic Lorentzian linewidth.
Step 4: Explain the limitation of the equation.
The equation
\[ \tau_{\mathrm{coh}}=\frac{1}{\pi\Delta\nu} \]
requires a Lorentzian spectral line and the specified coherence-time convention.
The long-term averaged spectrum is not necessarily Lorentzian. Its shape depends on how the frequency drifts and how the measurement averages that drift.
Therefore, the student cannot automatically interpret \(0.76\ \mathrm{\mu s}\) as the laser’s intrinsic coherence time.
This question highlights an important experimental distinction: a laser can have good short-term coherence but poor long-term frequency stability.
Question 5
This final problem combines cavity resonance, gain bandwidth, longitudinal mode selection, and linewidth.
Consider a linear laser cavity containing air.
Its initial mirror separation is
\[ L_0=0.300\ \mathrm{m} \]
The gain medium has a fixed gain peak at
\[ \nu_g=5.00\times10^{14}\ \mathrm{Hz} \]
Initially, longitudinal mode
\[ m=1\,000\,000 \]
has a resonant frequency exactly equal to the gain peak.
The laser operates in only one longitudinal mode at a time.
For this idealised model, assume that:
- The cavity refractive index remains \(n=1.00\).
- The gain peak does not move when the cavity length changes.
- At any instant, only the longitudinal mode closest to the gain peak has sufficient net gain to lase.
- No two modes lase simultaneously.
- Each stable lasing mode has a Lorentzian linewidth of \(10\ \mathrm{kHz}\).
The cavity length is slowly increased by \(200\ \mathrm{nm}\).
Determine:
(a) The initial free spectral range.
(b) Which longitudinal mode is selected after the length increase.
(c) The final frequency of the selected mode relative to the gain peak.
(d) Approximately how much must the cavity length increase before the laser switches from mode \(m\) to mode \(m+1\).
(e) Whether the mode switch means that the laser linewidth has increased to approximately \(500\ \mathrm{MHz}\).
Solution 5
The laser switches to longitudinal mode \(m+1\). Its final frequency is approximately \(166.7\ \mathrm{MHz}\) above the gain peak. The mode switch occurs at a cavity length increase of approximately \(150\ \mathrm{nm}\), but the individual laser linewidth remains \(10\ \mathrm{kHz}\) under the stated assumptions.
This problem has a tempting trap.
If we track only the original mode number, increasing cavity length must decrease its resonant frequency.
That prediction is correct for a fixed mode number.
However, the laser is not required to remain in that mode. The gain medium favours frequencies near its fixed gain peak, so the selected mode can change.
Step 1: Calculate the initial free spectral range.
For a linear cavity,
\[ \Delta\nu_{\mathrm{FSR}} = \frac{c}{2nL_0} \]
Substitute:
\[ \Delta\nu_{\mathrm{FSR}} = \frac{3.00\times10^8} {2(1.00)(0.300)} \]
\[ \boxed{ \Delta\nu_{\mathrm{FSR}} =500\ \mathrm{MHz} } \]
The initial adjacent longitudinal modes are separated by \(500\ \mathrm{MHz}\).
The given mode \(m\) is exactly at the gain peak.
Step 2: Calculate the new cavity length.
The increase is
\[ \Delta L=200\ \mathrm{nm} \]
Convert to metres:
\[ \Delta L=200\times10^{-9}\ \mathrm{m} \]
Therefore,
\[ L'=0.3000002\ \mathrm{m} \]
Step 3: Calculate the new free spectral range.
\[ \Delta\nu_{\mathrm{FSR}}' = \frac{c}{2nL'} \]
\[ \Delta\nu_{\mathrm{FSR}}' = \frac{3.00\times10^8} {2(1.00)(0.3000002)} \]
\[ \boxed{ \Delta\nu_{\mathrm{FSR}}' \approx499.999667\ \mathrm{MHz} } \]
The mode spacing has decreased slightly.
Step 4: Calculate the new frequency of the original mode.
For the original mode number,
\[ \nu_m'=\frac{mc}{2nL'} \]
Since the mode number is \(1\,000\,000\),
\[ \nu_m' = 1\,000\,000 (499.999667\times10^6) \]
\[ \nu_m'\approx4.999996667\times10^{14}\ \mathrm{Hz} \]
Relative to the gain peak,
\[ \nu_m'-\nu_g \approx-333.3\ \mathrm{MHz} \]
The original mode has shifted below the gain peak.
Step 5: Calculate the frequency of the adjacent higher mode.
The adjacent higher mode has mode number
\[ m+1=1\,000\,001 \]
Its frequency is
\[ \nu_{m+1}' = (m+1)\Delta\nu_{\mathrm{FSR}}' \]
Substituting:
\[ \nu_{m+1}' = 1\,000\,001 (499.999667\times10^6) \]
\[ \nu_{m+1}' \approx5.000001667\times10^{14}\ \mathrm{Hz} \]
Its detuning from the gain peak is
\[ \nu_{m+1}'-\nu_g \approx+166.7\ \mathrm{MHz} \]
Compare the two modes:
| Mode | Detuning from gain peak |
|---|---|
| \(m\) | \(-333.3\ \mathrm{MHz}\) |
| \(m+1\) | \(+166.7\ \mathrm{MHz}\) |
Mode \(m+1\) is closer to the gain peak.
Therefore, the laser switches to
\[ \boxed{m+1=1\,000\,001} \]
Its final frequency is approximately \(166.7\ \mathrm{MHz}\) above the gain peak.
Step 6: Determine when the mode switch occurs.
Initially, mode \(m\) sits exactly at the gain peak.
As the cavity length increases, its frequency decreases.
At the switching point, the gain peak lies halfway between modes \(m\) and \(m+1\). Both modes are then equally distant from the gain peak.
The original mode must shift down by approximately half the initial free spectral range:
\[ |\Delta\nu| \approx\frac{500\ \mathrm{MHz}}{2} \]
\[ |\Delta\nu|\approx250\ \mathrm{MHz} \]
For a fixed mode number, the small-change relationship is
\[ \frac{\Delta\nu}{\nu} \approx-\frac{\Delta L}{L} \]
Therefore,
\[ \frac{250\times10^6}{5.00\times10^{14}} \approx \frac{\Delta L}{0.300} \]
Rearranging:
\[ \Delta L \approx 0.300 \left( \frac{250\times10^6} {5.00\times10^{14}} \right) \]
\[ \boxed{ \Delta L\approx150\ \mathrm{nm} } \]
Just beyond this point, mode \(m+1\) becomes closer to the gain peak and is selected.
Step 7: Determine whether the mode switch increases linewidth.
No. The mode switch does not automatically increase the linewidth to \(500\ \mathrm{MHz}\).
This is the most important distinction in the problem.
The linewidth describes the width of an individual spectral line.
The mode switch changes which longitudinal mode is producing the output. It shifts the central frequency from one resonant mode to another.
Immediately before the switch, the laser operates near the lower-frequency mode. Immediately after, it operates near the higher-frequency mode.
The frequency jump is approximately one free spectral range:
\[ \Delta\nu_{\mathrm{hop}}\approx500\ \mathrm{MHz} \]
However, each stable mode still has its specified linewidth of \(10\ \mathrm{kHz}\).
If an instrument records the output across the mode switch, it may detect two narrow peaks separated by approximately \(500\ \mathrm{MHz}\), or a broader time-averaged distribution.
That does not mean the individual laser lines have acquired a \(500\ \mathrm{MHz}\) intrinsic linewidth.
In a real laser, mode competition, overlapping gain, and hysteresis can affect the precise switching point. The nearest-mode rule used here deliberately removes those complications so that the interaction between cavity length and mode selection can be isolated.
The surprising result is that increasing cavity length can cause the selected laser frequency to jump upwards, even though the resonant frequency of every fixed-index cavity mode decreases.
That is the difference between tracking one resonance and tracking the mode that the laser actually selects.
09What this lets you understand next
Laser linewidth connects three ideas that are easy to treat separately:
- The electromagnetic wave model explains how light propagates.
- The optical cavity determines which longitudinal frequencies are favoured.
- Phase fluctuations determine how narrow the emitted spectral line can remain and, therefore, how long temporal coherence persists.
The next useful concept is laser frequency stabilisation.
Once you understand that tiny changes in cavity length can shift the resonant frequency, you can see why precision lasers use temperature control, vibration isolation, and feedback systems to maintain a stable optical frequency.
The goal is not simply to produce light at one frequency. It is to keep that frequency, and its phase relationship over time, as predictable as the application requires.