tutorgum
Try a Class

Skin Effect: Frequency, Skin Depth and AC Resistance

Explore why AC current concentrates near a conductor's surface, calculate skin depth and connect frequency with resistance in this physics extension guide.

A 4 mm diameter copper wire carrying 50 Hz alternating current uses almost its entire cross-section to carry current. Drive the same wire at 1 MHz, however, and the current becomes concentrated in a layer only about 0.066 mm deep. The copper hasn’t changed. The frequency has.

This is called the skin effect. It explains why alternating current does not necessarily distribute evenly through a conductor, and why a wire’s resistance can increase as the frequency of its current increases.

The skin effect is an extension beyond the required content of the NSW Physics 11-12 Syllabus (2025). The Year 12 Electromagnetism focus develops the necessary foundations, including electromagnetic induction, eddy currents, alternating current, and resistive heating, but does not require you to study the skin effect itself. Your Year 12 knowledge is the starting point here, not an additional HSC assessment requirement.

Before we get to the mathematics, consider this: if you increase the frequency of an alternating current by a factor of 100, does the depth to which current penetrates a wire decrease by a factor of 100?

Not quite. The relationship involves a square root, and understanding why takes us back to Faraday’s law and Lenz’s law.

01Why does current concentrate near the surface?

Start with a wire carrying direct current

Imagine a long, straight copper wire connected to a battery. Once the current becomes steady, it produces a magnetic field around the wire.

In an ideal, uniform conductor, the current density is approximately the same throughout the wire’s cross-section.

Now replace the battery with an alternating current supply.

The current repeatedly changes magnitude and direction. Its magnetic field changes with it. This creates an important difference: the conductor is now experiencing a continuously changing magnetic field produced by its own current.

The role of electromagnetic induction

You have already encountered the relevant mechanism in Year 12 Electromagnetism.

Faraday’s law tells us that a changing magnetic flux induces an electromotive force (emf). For a coil containing \(N\) turns:

\[ |\varepsilon|=N\left|\frac{\Delta\Phi}{\Delta t}\right| \]

Here:

  • \(\varepsilon\) is the induced emf, measured in volts.
  • \(N\) is the number of turns in the coil.
  • \(\Phi\) is magnetic flux, measured in webers.
  • \(\Delta\Phi\) is the change in magnetic flux.
  • \(\Delta t\) is the time over which that change occurs.

For a uniform magnetic field passing through a flat loop:

\[ \Phi=BA\cos\theta \]

where \(B\) is magnetic field strength, \(A\) is the loop area, and \(\theta\) is the angle between the magnetic field and the area vector (the normal to the loop).

Lenz’s law tells us the direction of the induced current: its magnetic field opposes the change in magnetic flux that produced it.

This is the same principle behind eddy currents in transformer cores and magnetic braking systems.

What happens inside the wire?

The changing current in a wire produces a changing magnetic field within and around the conductor.

That changing field induces electric fields inside the metal. These fields alter the total electric field driving charge through different regions of the conductor.

The important result is that the changing magnetic field is increasingly opposed within the conductor’s interior. The current density becomes greater near the surface and smaller towards the centre.

A useful way to picture this is to imagine the temperature at the surface of a thick wall changing repeatedly. If the temperature changes slowly, the temperature variation can penetrate further into the wall. If it changes extremely quickly, only a shallow region responds significantly before the surface changes again.

The analogy is about how deeply a changing influence penetrates. In a conductor, it is electromagnetic fields rather than heat that are responsible.

There is one important qualification: the skin effect does not mean that current suddenly stops at some boundary inside the wire. The current density decreases gradually. There is no sharp dividing line between the conducting surface and a non-conducting centre.

02Skin depth: measuring how far current penetrates

We need a way to describe how concentrated the current becomes.

The key quantity is called the skin depth, represented by the Greek letter \(\delta\) (delta).

Skin depth is defined as the distance below a conductor’s surface at which the magnitude of the alternating current density has fallen to approximately 37% of its surface value.

Mathematically:

\[ J(x)=J_s e^{-x/\delta} \]

where:

  • \(J(x)\) is the magnitude of current density at depth \(x\).
  • \(J_s\) is the current density at the surface.
  • \(x\) is the distance measured inwards from the conductor’s surface, in metres.
  • \(\delta\) is the skin depth, in metres.
  • \(e\) is Euler’s number, approximately 2.718.

The exponential relationship describes how quickly the current density decreases as you move into the conductor.

Consider what happens at different depths:

Depth below surfaceCurrent density relative to surface
\(0\)100%
\(\delta\)36.8%
\(2\delta\)13.5%
\(3\delta\)5.0%
\(4\delta\)1.8%

Notice that the current density has not reached zero at three skin depths. It has simply become much smaller.

There is another detail worth knowing: the alternating current also changes phase with depth. This means the current at the surface and the current deeper inside do not reach their maximum values at exactly the same time.

The equation above describes the magnitude of the current density, not this additional phase change.

The skin depth equation

For a good electrical conductor carrying sinusoidal alternating current, skin depth is given by:

\[ \boxed{\delta=\sqrt{\frac{2}{\omega\mu\sigma}}} \]

This is the standard skin-depth relationship derived from electromagnetic field theory.

We can also write it in terms of frequency and resistivity:

\[ \boxed{\delta=\sqrt{\frac{\rho}{\pi f\mu}}} \]

The two expressions are equivalent.

Let’s define every quantity:

SymbolMeaningSI unit
\(\delta\)Skin depthm
\(\omega\)Angular frequencyrad s\(^{-1}\)
\(f\)FrequencyHz
\(\mu\)Absolute magnetic permeabilityH m\(^{-1}\)
\(\sigma\)Electrical conductivityS m\(^{-1}\)
\(\rho\)Electrical resistivity\(\Omega\) m

The relationships between these quantities are:

\[ \omega=2\pi f \]

\[ \sigma=\frac{1}{\rho} \]

Magnetic permeability can also be expressed as:

\[ \mu=\mu_0\mu_r \]

where:

  • \(\mu_0\) is the permeability of free space, approximately \(4\pi\times10^{-7}\,\mathrm{H\,m^{-1}}\).
  • \(\mu_r\) is the relative permeability of the conductor.

For copper and aluminium, we can usually approximate \(\mu_r\approx1\).

At approximately 20°C, copper has a resistivity of:

\[ \rho_{\mathrm{Cu}}=1.72\times10^{-8}\,\Omega\,\mathrm m \]

This gives us everything we need to estimate its skin depth at a particular frequency.

Why does frequency matter?

Look carefully at the skin-depth equation:

\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]

For a particular conductor, resistivity and permeability are approximately constant.

Therefore:

\[ \boxed{\delta\propto\frac{1}{\sqrt f}} \]

This is the relationship we were looking for earlier.

Skin depth is inversely proportional to the square root of frequency.

It does not decrease in direct proportion to frequency.

For example:

  • Double the frequency, and skin depth becomes approximately \(1/\sqrt2\) of its original value.
  • Increase frequency by a factor of 4, and skin depth halves.
  • Increase frequency by a factor of 100, and skin depth becomes one-tenth of its original value.

Why?

A higher frequency means the current changes direction more rapidly. Its magnetic field also changes more rapidly, increasing the electromagnetic induction responsible for opposing field changes within the conductor.

The result is less penetration into the interior.

For copper at approximately 20°C, the skin depth changes considerably with frequency:

FrequencyApproximate skin depth
50 Hz9.3 mm
500 Hz2.95 mm
50 kHz0.295 mm
1 MHz0.066 mm

At 50 Hz, the skin depth is larger than the radius of many ordinary wires. The current can therefore use almost the entire cross-section.

At 1 MHz, the skin depth is only 66 micrometres. A substantial amount of the metal towards the centre contributes very little to carrying the alternating current.

An important distinction: skin depth is a property of the material and the frequency, not the physical radius of the wire. The radius determines how significant the skin effect is for that particular conductor.

When is the skin effect significant?

A useful decision is to compare skin depth with the conductor’s radius, \(a\).

ComparisonWhat it tells you
\(\delta\gg a\)Current is approximately uniform. Skin effect is weak.
\(\delta\approx a\)Current distribution is noticeably non-uniform.
\(\delta\ll a\)Strong skin effect. Most current is concentrated near the surface.

This comparison is particularly useful because the skin-depth equation alone does not tell you whether a particular wire experiences a significant effect.

A skin depth of 1 mm means something very different for a wire with a radius of 0.5 mm than it does for a wire with a radius of 20 mm.

03Why does the skin effect increase resistance?

So far, we’ve established that alternating current becomes concentrated near the conductor’s surface.

But why does that matter for electrical energy losses?

Remember the standard resistance equation:

\[ R=\frac{\rho L}{A} \]

where:

  • \(R\) is electrical resistance, measured in ohms.
  • \(\rho\) is resistivity, measured in \(\Omega\,\mathrm m\).
  • \(L\) is conductor length, measured in metres.
  • \(A\) is cross-sectional area, measured in square metres.

For steady DC, we can generally use the entire cross-sectional area of a uniform wire.

For AC experiencing a strong skin effect, the situation changes.

The current is concentrated in a relatively thin region near the outside of the conductor. The effective area available to carry that current is therefore smaller.

Smaller effective area means greater resistance.

We distinguish between:

  • \(R_{\mathrm{dc}}\): the resistance under steady direct current.
  • \(R_{\mathrm{ac}}\): the effective resistance under alternating current at a specified frequency.

When skin effect is significant:

\[ R_{\mathrm{ac}}>R_{\mathrm{dc}} \]

Estimating AC resistance in a round wire

Consider a long cylindrical wire with radius \(a\), length \(L\), and skin depth much smaller than its radius.

We can approximate the effective conducting region as a thin cylindrical shell of thickness \(\delta\).

The surface area of the cylinder is \(2\pi aL\). The approximate cross-sectional area of this thin shell is therefore:

\[ A_{\mathrm{eff}}\approx2\pi a\delta \]

Using the resistance equation:

\[ R_{\mathrm{ac}}\approx \frac{\rho L}{2\pi a\delta} \]

For DC, the full circular cross-section is available:

\[ R_{\mathrm{dc}}=\frac{\rho L}{\pi a^2} \]

Dividing the two expressions gives:

\[ \boxed{ \frac{R_{\mathrm{ac}}}{R_{\mathrm{dc}}} \approx\frac{a}{2\delta} } \]

This is a useful high-frequency approximation, not an exact description of the current distribution. It assumes that the skin depth is much smaller than the wire radius.

Since:

\[ \delta\propto\frac{1}{\sqrt f} \]

we obtain:

\[ \boxed{R_{\mathrm{ac}}\propto\sqrt f} \]

for a fixed, sufficiently thick cylindrical conductor in this regime.

So increasing frequency increases the AC resistance, but the resistance does not increase linearly with frequency.

What happens to resistive heating?

The electrical power dissipated as heat in a conductor is:

\[ P=I_{\mathrm{rms}}^2R_{\mathrm{ac}} \]

where \(I_{\mathrm{rms}}\) is the root-mean-square alternating current.

If the RMS current remains constant, increasing AC resistance increases resistive heating.

This is important in electrical cables, transformer windings, and high-frequency circuits.

A conductor may have plenty of metal in its centre, but that metal might contribute very little to carrying current at high frequencies.

One engineering response is litz wire. It contains many individually insulated, finely stranded conductors, arranged so that the strands are transposed through the bundle.

If each strand is sufficiently thin compared with the skin depth, current can distribute more evenly through each strand. The arrangement can also reduce proximity effects, which occur when nearby conductors influence one another’s current distributions.

Where does this model stop being accurate?

The equations we’ve used are powerful, but they have assumptions.

The standard skin-depth expression assumes:

  • A good conductor, where conduction current dominates displacement current.
  • A uniform, homogeneous conducting material.
  • Approximately constant resistivity and magnetic permeability.
  • Sinusoidal alternating current in steady-state conditions.
  • A material whose magnetic permeability can be treated as constant over the frequency range considered.

The exponential current-density expression is exact for an idealised flat, effectively semi-infinite conductor. For a round wire, it is a good approximation near the surface when the skin depth is much smaller than the radius.

When the skin depth is comparable to or greater than the wire radius, the exact current distribution must account for the cylindrical geometry. We don’t need the more advanced mathematics here.

There are two other effects to keep in mind:

Proximity effect: Nearby conductors produce magnetic fields that further distort the current distribution. This can increase AC resistance beyond the skin effect alone.

Magnetic materials: Iron and steel can have much greater magnetic permeability than copper. Their skin depths can be considerably smaller. However, their permeability may change with frequency and magnetic field strength, so treating it as a fixed number can become unreliable.

The model is most useful when you understand what it assumes and check whether those assumptions suit the situation.

04Worked examples

Worked example: Is skin effect significant in a 2 mm copper wire at 10 kHz?

An isolated copper wire has a diameter of 2.0 mm and carries a sinusoidal alternating current at 10 kHz.

Estimate its skin depth and determine whether the current distribution is approximately uniform.

Take the copper resistivity as \(1.72\times10^{-8}\,\Omega\,\mathrm m\), and assume its relative permeability is 1.

Step 1

Since copper is approximately non-magnetic:

\[ \mu=\mu_0=4\pi\times10^{-7}\,\mathrm{H\,m^{-1}} \]

The frequency is:

\[ f=10\,\mathrm{kHz}=1.0\times10^4\,\mathrm{Hz} \]

Step 2

\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]

Step 3

\[ \delta= \sqrt{ \frac{1.72\times10^{-8}} {\pi(1.0\times10^4)(4\pi\times10^{-7})} } \]

\[ \delta=6.6\times10^{-4}\,\mathrm m \]

Therefore:

\[ \boxed{\delta=0.66\,\mathrm{mm}} \]

Step 4

The wire diameter is 2.0 mm, so:

\[ a=\frac{2.0}{2}=1.0\,\mathrm{mm} \]

Comparing:

\[ \frac{\delta}{a}=\frac{0.66}{1.0}=0.66 \]

The skin depth is smaller than the radius, but not dramatically smaller.

Conclusion: The wire experiences noticeable skin effect, with greater current density near its surface. However, the current is not restricted to an extremely thin outer shell. A more precise calculation would account for the wire’s cylindrical geometry.

Worked example: How much does AC resistance increase at 1 MHz?

A solid copper wire has a diameter of 4.0 mm and carries an RMS current of 2.0 A at 1.0 MHz.

Estimate its skin depth and the ratio of its AC resistance to its DC resistance.

Assume the wire is isolated from nearby conductors, its temperature is approximately 20°C, and the high-frequency approximation is valid.

Step 1

\[ a=\frac{4.0}{2}=2.0\,\mathrm{mm} \]

Step 2

Using:

\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]

Substitute:

\[ \delta= \sqrt{ \frac{1.72\times10^{-8}} {\pi(1.0\times10^6)(4\pi\times10^{-7})} } \]

\[ \delta=6.6\times10^{-5}\,\mathrm m \]

Therefore:

\[ \boxed{\delta=0.066\,\mathrm{mm}} \]

Step 3

Compare the skin depth with the wire radius:

\[ \frac{\delta}{a}=\frac{0.066}{2.0}=0.033 \]

The skin depth is only about 3.3% of the wire radius.

The current is therefore strongly concentrated near the surface, making the thin-shell approximation reasonable.

Step 4

For a thick round conductor:

\[ \frac{R_{\mathrm{ac}}}{R_{\mathrm{dc}}} \approx\frac{a}{2\delta} \]

Substituting:

\[ \frac{R_{\mathrm{ac}}}{R_{\mathrm{dc}}} \approx \frac{2.0}{2(0.066)} \]

\[ \boxed{\frac{R_{\mathrm{ac}}}{R_{\mathrm{dc}}}\approx15.2} \]

Step 5

The RMS current is unchanged, so:

\[ P=I_{\mathrm{rms}}^2R \]

Consequently:

\[ \frac{P_{\mathrm{ac}}}{P_{\mathrm{dc}}} \approx15.2 \]

Conclusion: Under these assumptions, the wire’s effective AC resistance and resistive heating are approximately 15 times their DC values at the same current.

The key is not that copper has become a poorer conductor. Rather, the high-frequency current uses a much smaller effective region of the available metal.

05Questions and solutions

Question 1

A solid copper wire has a radius of 1.0 mm and carries sinusoidal alternating current at 50 Hz.

Given:

\[ \rho=1.72\times10^{-8}\,\Omega\,\mathrm m \]

\[ \mu_r=1 \]

Calculate the skin depth and explain whether the wire experiences significant skin effect.

Solution 1

The skin depth is approximately 9.3 mm, so the wire experiences very little skin effect. Its current is distributed approximately uniformly across its cross-section.

Step 1: Calculate the absolute permeability.

\[ \mu=\mu_0\mu_r \]

\[ \mu=4\pi\times10^{-7}\,\mathrm{H\,m^{-1}} \]

Step 2: Apply the skin-depth equation.

\[ \delta=\sqrt{\frac{\rho}{\pi f\mu}} \]

Substitute:

\[ \delta= \sqrt{ \frac{1.72\times10^{-8}} {\pi(50)(4\pi\times10^{-7})} } \]

\[ \delta=9.33\times10^{-3}\,\mathrm m \]

Therefore:

\[ \boxed{\delta=9.3\,\mathrm{mm}} \]

Step 3: Compare the skin depth with the wire radius.

\[ \delta=9.3\,\mathrm{mm} \]

\[ a=1.0\,\mathrm{mm} \]

Since:

\[ \delta\gg a \]

the skin depth is much greater than the wire radius.

The wire is too small for strong current concentration near its surface at this frequency.

A common mistake is to interpret 9.3 mm as the thickness of a current-carrying shell that must fit inside the wire. Skin depth is a characteristic penetration distance, not a physical boundary. Here, the distance is greater than the entire radius, so current can use almost all the available metal.

Question 2

A copper wire has a radius of 1.0 mm. Its operating frequency increases from 400 Hz to 40 kHz.

Assume its temperature and material properties remain constant.

(a) Calculate the skin depth at both frequencies.

(b) By what factor does the skin depth change?

(c) Explain how the current distribution changes as the frequency increases.

Solution 2

The skin depth decreases from approximately 3.3 mm to 0.33 mm, a reduction by a factor of 10. The current becomes significantly more concentrated near the wire’s surface.

Step 1: Calculate the skin depth at 400 Hz.

\[ \delta_1=\sqrt{\frac{\rho}{\pi f_1\mu_0}} \]

Substituting:

\[ \delta_1= \sqrt{ \frac{1.72\times10^{-8}} {\pi(400)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_1=3.3\,\mathrm{mm}} \]

Step 2: Calculate the skin depth at 40 kHz.

\[ \delta_2= \sqrt{ \frac{1.72\times10^{-8}} {\pi(40000)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_2=0.33\,\mathrm{mm}} \]

Step 3: Calculate the change in skin depth.

\[ \frac{\delta_1}{\delta_2} = \frac{3.3}{0.33} \]

\[ \boxed{\frac{\delta_1}{\delta_2}=10} \]

The frequency increased by a factor of:

\[ \frac{40000}{400}=100 \]

This is exactly what we expect from:

\[ \delta\propto\frac{1}{\sqrt f} \]

A 100-fold frequency increase produces a 10-fold reduction in skin depth.

Step 4: Explain the change in current distribution.

At 400 Hz:

\[ \delta=3.3\,\mathrm{mm}>a \]

The current distribution is approximately uniform.

At 40 kHz:

\[ \delta=0.33\,\mathrm{mm}<a \]

The current density decreases more noticeably as we move towards the centre.

At one skin depth below the surface, the current-density magnitude is approximately 36.8% of its surface value.

The tempting prediction is that increasing frequency by 100 times should reduce penetration by 100 times. The square-root relationship changes that prediction. Frequency has a substantial effect, but not a linear one.

Question 3

An isolated copper conductor has a radius of 8.0 mm. It carries an RMS current of 3.0 A.

Its frequency increases from 100 kHz to 900 kHz.

Assume:

  • The conductor’s material properties remain constant.
  • Skin depth is much smaller than the conductor radius at both frequencies.
  • Proximity effects are negligible.
  • The RMS current remains constant.

(a) Calculate the skin depth at both frequencies.

(b) Estimate the ratio of the AC resistances at the two frequencies.

(c) Determine the ratio of the resistive power losses.

Solution 3

The skin depth becomes one-third of its original value, while both the AC resistance and resistive power loss increase by approximately a factor of 3.

Step 1: Calculate skin depth at 100 kHz.

\[ \delta_1= \sqrt{ \frac{1.72\times10^{-8}} {\pi(1.0\times10^5)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_1=0.209\,\mathrm{mm}} \]

Step 2: Calculate skin depth at 900 kHz.

\[ \delta_2= \sqrt{ \frac{1.72\times10^{-8}} {\pi(9.0\times10^5)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_2=0.0697\,\mathrm{mm}} \]

The conductor radius is 8.0 mm, much greater than either skin depth. Therefore, the high-frequency resistance approximation is suitable.

Step 3: Determine the resistance ratio.

For a thick cylindrical conductor:

\[ R_{\mathrm{ac}}\propto\frac{1}{\delta} \]

Therefore:

\[ \frac{R_{\mathrm{ac},2}}{R_{\mathrm{ac},1}} \approx\frac{\delta_1}{\delta_2} \]

\[ =\frac{0.209}{0.0697} \]

\[ \boxed{\frac{R_{\mathrm{ac},2}}{R_{\mathrm{ac},1}}\approx3} \]

Step 4: Determine the power-loss ratio.

Using:

\[ P=I_{\mathrm{rms}}^2R_{\mathrm{ac}} \]

The RMS current is constant, so:

\[ \frac{P_2}{P_1} = \frac{R_{\mathrm{ac},2}}{R_{\mathrm{ac},1}} \]

\[ \boxed{\frac{P_2}{P_1}\approx3} \]

The resistive power loss triples.

A tempting answer is that the resistance should increase ninefold because the frequency increases ninefold. However, this ignores the square-root relationship between frequency and skin depth.

The important interaction is:

\[ R_{\mathrm{ac}}\propto\frac{1}{\delta} \propto\sqrt f \]

That is why the resistance and heating increase by a factor of 3 rather than 9.

Question 4

A transformer contains a laminated steel core and solid copper windings.

Each copper winding wire has a radius of 2.0 mm.

The transformer is initially operated at 50 Hz. An engineer considers operating it at 5.0 kHz.

(a) Calculate the skin depth in the copper winding at both frequencies.

(b) Explain why laminating the steel core reduces eddy-current losses.

(c) Explain why the laminated core does not eliminate skin effect in the copper windings.

(d) Suggest a suitable modification to the winding design if skin effect becomes significant.

Assume copper has a resistivity of \(1.72\times10^{-8}\,\Omega\,\mathrm m\), and \(\mu_r=1\).

Solution 4

At 5.0 kHz, the copper winding has a skin depth of approximately 0.93 mm, compared with 9.3 mm at 50 Hz. Laminating the steel core reduces eddy-current losses within the core, but it does not prevent current redistribution inside the copper winding.

Part (a): Skin depth

At 50 Hz:

\[ \delta_1= \sqrt{ \frac{1.72\times10^{-8}} {\pi(50)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_1=9.3\,\mathrm{mm}} \]

At 5.0 kHz:

\[ \delta_2= \sqrt{ \frac{1.72\times10^{-8}} {\pi(5000)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_2=0.93\,\mathrm{mm}} \]

The frequency increases by a factor of 100, so the skin depth decreases by a factor of 10.

Part (b): Why does laminating the core reduce eddy-current losses?

A changing magnetic flux through the conducting steel core induces circulating currents within the material.

These currents produce resistive heating, which represents an energy loss in the transformer.

Dividing the core into thin, electrically insulated layers interrupts the large circulating current pathways.

The increased resistance of these smaller pathways reduces the magnitude of the eddy currents and therefore reduces their heating losses.

Part (c): Why does this not eliminate skin effect in the windings?

The two effects occur in different conductors and involve different current distributions.

In the steel core, lamination restricts the circulating eddy-current pathways.

In the copper windings, the alternating current produces its own changing magnetic field. This induces electric fields within the copper, producing a non-uniform current distribution.

Laminating the steel does not change the electromagnetic behaviour of the solid copper wire.

At 5.0 kHz, the skin depth is approximately:

\[ \delta=0.93\,\mathrm{mm} \]

Compared with the winding radius:

\[ a=2.0\,\mathrm{mm} \]

The skin depth is now smaller than the radius, so the current distribution is noticeably less uniform.

Part (d): A suitable winding modification

One suitable solution is to use litz wire.

Instead of one thick copper conductor, the winding uses many fine, individually insulated strands.

Each strand has a much smaller radius than the original wire. If the strands are sufficiently thin compared with the skin depth, current can distribute more evenly through each one.

The strands are also transposed through the bundle to help reduce the effects of nearby magnetic fields.

The key distinction is that core lamination interrupts unwanted circulating currents in the core, while litz wire addresses current distribution in the windings.

Question 5

An engineer is comparing copper and aluminium conductors for a high-frequency electrical system.

Both conductors are initially:

  • 1.0 m long.
  • 5.0 mm in radius.
  • Operated at 500 kHz.
  • Carrying the same RMS current of 10 A.
  • Isolated from nearby conductors.

At 20°C, use the following material properties:

PropertyCopperAluminium
Resistivity, \(\rho\)\(1.7\times10^{-8}\,\Omega\,\mathrm m\)\(2.8\times10^{-8}\,\Omega\,\mathrm m\)
Relative permeability, \(\mu_r\)11

The engineer argues:

“Aluminium has a higher resistivity, but its skin depth is also greater. This means more of its cross-section can carry current, so its AC resistance should be lower than copper’s.”

Evaluate this claim.

(a) Calculate the skin depth of each material.

(b) Determine the ratio of their high-frequency AC resistances.

(c) Determine which conductor produces more resistive heating when both carry the same RMS current.

(d) Estimate the radius an aluminium conductor would need to have to match the AC resistance per unit length of the original copper conductor.

Assume both conductors remain in the high-frequency regime, where skin depth is much smaller than their radius. Treat their resistivity and permeability as constant.

Solution 5

The engineer’s conclusion is incorrect. Aluminium has a greater skin depth, but its high-frequency AC resistance is also greater. For the same length and radius, its AC resistance and resistive heating are approximately 1.28 times those of copper.

This is the most important part of the question: greater penetration does not automatically mean lower resistance. We must consider both the effective conducting area and the resistivity of the material.

Part (a): Calculate both skin depths

For copper:

\[ \delta_{\mathrm{Cu}}= \sqrt{ \frac{1.7\times10^{-8}} {\pi(5.0\times10^5)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_{\mathrm{Cu}}=0.0928\,\mathrm{mm}} \]

For aluminium:

\[ \delta_{\mathrm{Al}}= \sqrt{ \frac{2.8\times10^{-8}} {\pi(5.0\times10^5)(4\pi\times10^{-7})} } \]

\[ \boxed{\delta_{\mathrm{Al}}=0.119\,\mathrm{mm}} \]

Aluminium has the greater skin depth.

We can also verify the relationship using the ratio:

\[ \frac{\delta_{\mathrm{Al}}}{\delta_{\mathrm{Cu}}} = \sqrt{\frac{\rho_{\mathrm{Al}}}{\rho_{\mathrm{Cu}}}} \]

\[ = \sqrt{\frac{2.8}{1.7}} \]

\[ \boxed{\frac{\delta_{\mathrm{Al}}}{\delta_{\mathrm{Cu}}}=1.28} \]

The aluminium skin depth is approximately 28% greater.

Part (b): Compare AC resistance

Both conductors have a radius of 5.0 mm, which is much greater than their skin depths.

We can therefore use:

\[ R_{\mathrm{ac}}\approx \frac{\rho L}{2\pi a\delta} \]

For equal lengths and radii:

\[ \frac{R_{\mathrm{ac,Al}}}{R_{\mathrm{ac,Cu}}} = \frac{\rho_{\mathrm{Al}}}{\rho_{\mathrm{Cu}}} \times \frac{\delta_{\mathrm{Cu}}}{\delta_{\mathrm{Al}}} \]

Substituting:

\[ = \frac{2.8}{1.7} \times \frac{0.0928}{0.119} \]

\[ \boxed{ \frac{R_{\mathrm{ac,Al}}}{R_{\mathrm{ac,Cu}}} \approx1.28 } \]

Therefore, aluminium has approximately 28% greater AC resistance.

Why?

Its resistivity is approximately 65% greater than copper’s:

\[ \frac{\rho_{\mathrm{Al}}}{\rho_{\mathrm{Cu}}} = 1.65 \]

However, its skin depth is only approximately 28% greater.

The increased effective conducting area does not compensate for the higher resistivity.

In fact, combining the two effects gives:

\[ R_{\mathrm{ac}}\propto\sqrt{\rho} \]

for the same geometry and frequency in the high-frequency regime.

Part (c): Compare resistive heating

Both conductors carry the same RMS current:

\[ I_{\mathrm{rms}}=10\,\mathrm A \]

Using:

\[ P=I_{\mathrm{rms}}^2R_{\mathrm{ac}} \]

The ratio of their power losses is:

\[ \frac{P_{\mathrm{Al}}}{P_{\mathrm{Cu}}} = \frac{R_{\mathrm{ac,Al}}}{R_{\mathrm{ac,Cu}}} \]

Therefore:

\[ \boxed{ \frac{P_{\mathrm{Al}}}{P_{\mathrm{Cu}}} \approx1.28 } \]

The aluminium conductor produces approximately 28% more resistive heating under the stated conditions.

Part (d): Find the aluminium radius required to match copper’s AC resistance

For a thick cylindrical conductor:

\[ R_{\mathrm{ac}}\approx \frac{\rho L}{2\pi a\delta} \]

At fixed frequency and material, this means:

\[ R_{\mathrm{ac}}\propto\frac{1}{a} \]

The aluminium conductor initially has 1.28 times the AC resistance of the copper conductor.

To obtain equal resistance, its radius must increase by the same factor:

\[ a_{\mathrm{Al}}=1.28a_{\mathrm{Cu}} \]

\[ a_{\mathrm{Al}}=1.28(5.0) \]

\[ \boxed{a_{\mathrm{Al}}=6.4\,\mathrm{mm}} \]

This is still comfortably within the high-frequency approximation because the aluminium skin depth remains much smaller than its new radius.

Final interpretation

The engineer has correctly identified that aluminium has a greater skin depth, but has drawn the wrong conclusion about resistance.

Two competing properties matter:

  • Greater resistivity increases electrical resistance.
  • Greater skin depth increases the effective region carrying current, reducing the penalty from current concentration.

The second effect only partly compensates for the first.

This is why skin depth cannot be considered independently of the material’s resistivity when comparing conductors.

06Where to take this next

The skin effect explains how a conductor’s own alternating magnetic field changes its current distribution. In real electrical systems, however, conductors rarely operate in complete isolation.

Nearby wires, transformer windings, and adjacent cable strands produce additional magnetic fields that can redistribute current even further.

That leads to the proximity effect, which is the next useful concept when analysing high-frequency transformer windings and closely packed conductors.

07Sources and further reading

The syllabus boundary and scientific relationships in this article have been checked against the following resources: