How Energy Crosses the Air Gap in an Induction Motor
Learn how a rotating magnetic field transfers energy from the stator to the rotor without a direct electrical connection. Explore induced rotor current, slip, torque, and energy conversion through worked HSC Physics examples.
A squirrel-cage induction motor can deliver useful mechanical power at its shaft even though its rotor has no electrical cable connecting it to the supply. So where does the rotor get its energy?
Predict what would happen if you powered the stator but left the rotor completely disconnected from every electrical wire. Would it remain stationary?
It wouldn’t. Energy crosses the small gap between the stator and rotor through the electromagnetic field. The stator produces a rotating magnetic field, which induces an EMF and current in the rotor. The interaction between that current and the magnetic field produces torque.
The important distinction is that energy crosses the air gap, but electrons do not. The current in the stator stays in the stator windings, and the induced current flows through the rotor conductors.
01The answer: electromagnetic energy transfer
Start by separating the motor into two main parts.
- The stator is the stationary outer section. Its windings are connected to the AC supply.
- The rotor is the inner section. It rotates with the shaft and contains conducting bars connected into closed electrical circuits.
A small air gap separates these components. They do not need to touch for the motor to operate.
The stator produces a magnetic field that extends across this gap and links the rotor conductors. As the field moves relative to the rotor, it induces an EMF in those conductors.
The resulting current interacts with the magnetic field to produce an electromagnetic force and, therefore, torque.
The energy transfer follows this sequence:
- Electrical energy enters the stator through the AC supply.
- The stator produces a rotating magnetic field.
- Electromagnetic energy is transferred across the air gap.
- The changing magnetic flux induces current in the rotor.
- The interaction between rotor current and magnetic field produces torque.
- Mechanical energy is delivered through the rotating shaft.
This is electromagnetic energy transfer, not electrical conduction between the two components.
Engineers call the real power transferred electromagnetically from the stator to the rotor the air-gap power, represented by \(P_g\).
It is important to distinguish this from both the electrical input power and the useful mechanical output power. Some energy is lost as heat in the windings and rotor, while mechanical friction and air resistance also reduce the power available at the shaft.
01How the stator creates a rotating magnetic field
The first step is understanding what actually rotates.
The stator contains three sets of windings arranged around the motor. These windings are supplied with three-phase alternating current.
The currents have the same frequency but are separated in phase by \(120^\circ\).
Each winding produces a magnetic field. As the currents change, the individual magnetic fields change in strength and direction.
When the three fields combine, they produce a resultant magnetic field that rotates around the stator.
This is called a rotating magnetic field.
The speed of this rotating magnetic field is called the synchronous speed.
It depends on the AC supply frequency and the number of magnetic poles in the stator.
The equation is:
\[ n_s=\frac{120f_s}{P} \]
Where:
- \(n_s\) is synchronous speed, measured in revolutions per minute (rpm).
- \(f_s\) is the stator supply frequency, measured in hertz (Hz).
- \(P\) is the total number of magnetic poles.
For example, consider a four-pole motor connected to Australia’s 50 Hz supply.
\[ n_s=\frac{120\times50}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
The magnetic field rotates at 1500 rpm.
Notice that the stator itself remains stationary. It is the resultant magnetic field that rotates.
This distinction becomes important when we examine how the field transfers energy to the rotor.
02How the rotating field induces current in the rotor
Now consider the space between the stator and rotor.
The rotating magnetic field extends across the air gap and passes through the conducting rotor structure.
In a common squirrel-cage induction motor, the rotor consists of conducting bars running parallel to the shaft. Conducting end rings connect the bars at both ends.
These connections create closed electrical paths through the rotor.
As the rotating magnetic field moves relative to the rotor conductors, the magnetic flux linking these circuits changes.
According to Faraday’s law of electromagnetic induction, a changing magnetic flux induces an EMF.
\[ \mathcal{E}=-N\frac{d\Phi}{dt} \]
Where:
- \(\mathcal{E}\) is the induced electromotive force (EMF), measured in volts (V).
- \(N\) is the number of turns in the conducting circuit.
- \(\Phi\) is magnetic flux, measured in webers (Wb).
- \(d\Phi/dt\) is the rate of change of magnetic flux.
The negative sign represents Lenz’s law: the induced current acts in a direction that opposes the change responsible for producing it.
Because the rotor bars form closed circuits, the induced EMF drives a current through them.
This is the crucial point: the rotor generates its own current through electromagnetic induction. It does not receive the stator’s current through a connecting wire.
The transformer connection
A useful way to picture this process is to compare an induction motor with a transformer.
In a transformer:
- The primary winding receives electrical energy.
- Its changing magnetic field links the secondary winding.
- An EMF is induced in the secondary.
- Current flows through the secondary circuit if it is closed.
An induction motor uses a related principle.
The stator acts like the primary winding, while the rotor behaves like a short-circuited secondary.
The important difference is that the rotor can rotate. The magnetic field moves relative to the rotor, so the rate at which the rotor experiences changing magnetic flux depends on their relative speed.
The transformer analogy explains how electrical energy can be transferred without a direct electrical connection. However, an induction motor also converts that transferred energy into mechanical motion.
03Why slip is necessary for energy transfer
If the rotor and rotating magnetic field moved at exactly the same speed, would the rotor still experience changing magnetic flux?
No.
The magnetic field would no longer move relative to the rotor at the fundamental rotating-field frequency. The flux linking the rotor circuits would no longer change in the way required to induce rotor current.
Without induced rotor current, the induction mechanism cannot produce its normal electromagnetic torque.
This is why an induction motor needs a speed difference between its rotating magnetic field and rotor.
That difference is called slip.
Slip is calculated using:
\[ s=\frac{n_s-n_r}{n_s} \]
Where:
- \(s\) is the slip ratio.
- \(n_s\) is synchronous speed in rpm.
- \(n_r\) is actual rotor speed in rpm.
For a normal induction motor operating in motoring mode, the rotor rotates slightly slower than the magnetic field, so slip is positive.
The frequency of the induced rotor current is also related to slip:
\[ f_r=sf_s \]
Where:
- \(f_r\) is rotor current frequency in Hz.
- \(s\) is the slip ratio.
- \(f_s\) is stator supply frequency in Hz.
This means the rotor current does not necessarily have the same frequency as the stator supply.
For example, if the slip is 4% and the supply frequency is 50 Hz:
\[ f_r=0.04\times50 \]
\[ \boxed{f_r=2\text{ Hz}} \]
The rotor current has a frequency of 2 Hz, even though the stator receives a 50 Hz supply.
As the rotor accelerates towards synchronous speed, slip decreases and the rotor current frequency decreases.
At synchronous speed, the ideal fundamental-field model gives zero slip, zero induced rotor EMF, and zero induction torque.
This explains why an induction motor cannot maintain a non-zero load torque at exactly synchronous speed.
Worked example: Calculate slip and rotor current frequency
A four-pole induction motor operates on a 50 Hz AC supply. A tachometer measures its rotor speed as 1464 rpm.
Calculate:
a) The synchronous speed.
b) The percentage slip.
c) The frequency of the induced rotor current.
Step 1
Use:
\[ n_s=\frac{120f_s}{P} \]
Substitute:
\[ n_s=\frac{120\times50}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
The rotating magnetic field moves at 1500 rpm.
Step 2
The rotor rotates at 1464 rpm, so:
\[ s=\frac{1500-1464}{1500} \]
\[ s=\frac{36}{1500} \]
\[ s=0.024 \]
Convert to a percentage:
\[ s=0.024\times100 \]
\[ \boxed{s=2.4\%} \]
Step 3
Use:
\[ f_r=sf_s \]
Substitute:
\[ f_r=0.024\times50 \]
\[ \boxed{f_r=1.2\text{ Hz}} \]
The induced rotor current has a frequency of 1.2 Hz.
The rotor experiences the rotating field at a much lower relative frequency than the original 50 Hz supply frequency. This relative motion is what allows induction to continue while the motor is operating.
04How induced rotor current produces mechanical power
We now have an induced current flowing through the rotor conductors.
But current alone does not explain how the motor turns.
The next step involves the motor effect.
A current-carrying conductor in a magnetic field experiences a force. The rotor bars carry induced current while sitting within the stator’s magnetic field.
The resulting magnetic forces have tangential components around the rotor. These components combine to produce a turning effect, or torque.
The rotor begins rotating in the direction of the rotating magnetic field.
There are two related processes here:
- Electromagnetic induction produces the rotor EMF and current.
- The motor effect produces the magnetic forces that create torque.
These are not competing explanations. They are two stages of the same energy-conversion process.
If you need to revise the distinction between the two mechanisms, see Motor Effect vs Electromagnetic Induction: HSC Physics Guide.
Where does the energy actually go?
This is where many explanations become incomplete.
It is tempting to say that the stator’s electrical energy simply becomes mechanical energy in the rotor. That skips several important losses.
In a real induction motor, energy follows a more detailed path.
- Electrical input power enters the stator.
- Some energy is lost through stator winding resistance and magnetic core losses.
- The remaining electromagnetic power crosses the air gap.
- Some of this power becomes heat in the rotor conductors.
- The rest is converted into mechanical power.
- Friction and air resistance reduce the final power available at the shaft.
The relationship can be represented as:
\[ P_{\text{in}}=P_{\text{stator losses}}+P_g \]
And:
\[ P_g=P_{\text{rotor copper losses}}+P_{\text{converted}} \]
Here, \(P_{\text{converted}}\) is the mechanical power developed internally by the rotor, before mechanical losses.
The useful shaft output is then:
\[ P_{\text{shaft}}=P_{\text{converted}}-P_{\text{mechanical losses}} \]
This explains why the mechanical output power is smaller than the electrical input power.
The air gap is where electromagnetic energy is transferred between the stationary and rotating parts. It is not where all the motor’s energy losses occur.
Calculating mechanical power at the shaft
Mechanical output power depends on torque and angular velocity.
\[ P_{\text{shaft}}=\tau\omega \]
Where:
- \(P_{\text{shaft}}\) is mechanical output power in watts (W).
- \(\tau\) is shaft torque in newton metres (N m).
- \(\omega\) is angular velocity in radians per second (rad/s).
If rotational speed is provided in rpm, convert it using:
\[ \omega=\frac{2\pi n_r}{60} \]
This allows you to connect the electromagnetic energy transfer to the useful mechanical output.
Worked example: Calculate shaft power and total motor losses
A six-pole induction motor operates on a 50 Hz supply.
Its rotor rotates at 960 rpm and delivers a shaft torque of 4.0 N m. The motor draws 500 W of real electrical input power.
Calculate:
a) The synchronous speed.
b) The slip and rotor current frequency.
c) The mechanical output power.
d) The total difference between electrical input and mechanical output power.
Step 1
\[ n_s=\frac{120f_s}{P} \]
\[ n_s=\frac{120\times50}{6} \]
\[ \boxed{n_s=1000\text{ rpm}} \]
Step 2
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1000-960}{1000} \]
\[ \boxed{s=0.04=4.0\%} \]
Step 3
\[ f_r=sf_s \]
\[ f_r=0.04\times50 \]
\[ \boxed{f_r=2.0\text{ Hz}} \]
Step 4
\[ \omega=\frac{2\pi n_r}{60} \]
\[ \omega=\frac{2\pi\times960}{60} \]
\[ \omega=100.53\text{ rad/s} \]
Step 5
\[ P_{\text{shaft}}=\tau\omega \]
\[ P_{\text{shaft}}=4.0\times100.53 \]
\[ \boxed{P_{\text{shaft}}=402\text{ W}} \]
Step 6
\[ P_{\text{difference}}=P_{\text{in}}-P_{\text{shaft}} \]
\[ P_{\text{difference}}=500-402 \]
\[ \boxed{P_{\text{difference}}=98\text{ W}} \]
The motor receives 500 W of electrical power and delivers approximately 402 W of mechanical power at its shaft.
The remaining 98 W represents the combined motor losses.
It is important not to call this 98 W the air-gap power. The difference includes losses in several parts of the motor. The air-gap power is the portion transferred to the rotor, before rotor copper and mechanical losses are deducted.
05How could an experiment demonstrate energy transfer across the gap?
So far, we’ve developed a physical explanation. But how could you investigate whether energy really reaches the rotor without an electrical connection?
A useful experiment measures both the electrical energy entering the motor and the mechanical energy leaving its shaft.
Setting up the apparatus
Consider a proposed investigation using a small, enclosed squirrel-cage induction motor test rig.
The apparatus consists of:
- A three-phase AC supply connected to the stator through a power analyser.
- A stationary stator surrounding a squirrel-cage rotor.
- An air gap separating the stator and rotor.
- A shaft extending from the rotor through the motor bearings.
- A torque transducer and adjustable dynamometer connected to the shaft.
- A non-contact tachometer measuring rotor speed.
The rotor has no electrical leads connected to it.
The power analyser measures real electrical input power. The torque transducer measures mechanical torque, while the tachometer measures rotational speed.
What should the experiment show?
Suppose a student predicts that the rotor cannot receive energy because it has no direct electrical connection to the supply.
When the stator is powered, however, the rotor begins turning.
This observation challenges the prediction. The motor can produce rotation without electrical contact between the stator and rotor.
But simply watching the rotor turn is not enough to establish how much energy is being transferred.
A freely rotating rotor might require very little useful mechanical output.
We need to improve the experiment.
Improving the measurement
Connect the shaft to the dynamometer and gradually increase the mechanical load.
At each steady operating condition, measure:
- Electrical input power.
- Rotor speed.
- Shaft torque.
The following readings are illustrative only. They are not measurements from a particular motor.
Assume a four-pole motor supplied at 50 Hz.
| Quantity | Light load | Heavier load |
|---|---|---|
| Rotor speed | 1470 rpm | 1440 rpm |
| Shaft torque | 0.80 N m | 3.0 N m |
| Electrical input power | 180 W | 560 W |
Calculate the mechanical output power for each condition.
For the light-load condition:
\[ \omega=\frac{2\pi\times1470}{60} \]
\[ \omega=153.94\text{ rad/s} \]
\[ P_{\text{shaft}}=0.80\times153.94 \]
\[ \boxed{P_{\text{shaft}}\approx123\text{ W}} \]
For the heavier-load condition:
\[ \omega=\frac{2\pi\times1440}{60} \]
\[ \omega=150.80\text{ rad/s} \]
\[ P_{\text{shaft}}=3.0\times150.80 \]
\[ \boxed{P_{\text{shaft}}\approx452\text{ W}} \]
The heavier-load condition produces substantially more mechanical output power.
Notice that the electrical input power also increases.
The rotor slows slightly, increasing slip. This allows the motor to develop the additional electromagnetic torque needed to drive the heavier load.
What does the experiment establish?
The important observation is that the motor delivers measurable mechanical power through a shaft, despite having no electrical connection between its stator and rotor.
There is also no direct mechanical contact between these two components.
The electromagnetic field across the air gap is therefore the mechanism that transfers energy to the rotor.
However, the experiment does not directly measure the air-gap power. The difference between electrical input and shaft output includes losses throughout the motor.
To calculate air-gap power accurately, the stator losses must also be accounted for.
The investigation supports the electromagnetic explanation without pretending that the energy transfer itself has been measured directly.
06How does an induction motor differ from other machines?
The presence of a magnetic field across an air gap does not automatically make a motor an induction motor.
Different machines establish their rotor magnetic fields in different ways.
| Machine | How the rotor receives its electrical or magnetic excitation | How torque is produced |
|---|---|---|
| AC induction motor | Rotor current is induced by the rotating stator field. | Induced rotor current interacts with the magnetic field. |
| Permanent-magnet synchronous motor | Permanent magnets provide the rotor magnetic field. | The rotor field interacts with the rotating stator field. |
| Brushed DC motor | Current enters the rotor armature through brushes and a commutator. | The motor effect acts on current-carrying conductors. |
| Transformer | Current is induced in a stationary secondary winding. | No rotational torque is produced. |
Induction motor versus synchronous motor
A synchronous motor can operate at exactly synchronous speed while producing torque.
Why doesn’t this contradict what we learned about slip?
Because its rotor field does not depend on induced rotor current.
In a permanent-magnet synchronous motor, permanent magnets establish the rotor field. The stator’s rotating field interacts with this rotor field to produce torque.
The rotor remains synchronised with the rotating stator field, with a non-zero angular displacement between their magnetic-field axes when delivering load torque.
An induction motor is different. Its rotor current is produced by electromagnetic induction, so it needs relative motion between the rotor and stator field.
Induction motor versus brushed DC motor
A brushed DC motor receives electrical current directly through its brushes and commutator.
The current flows into the rotating armature, where the motor effect produces forces on the conductors.
An induction motor does not need this direct electrical connection. Its rotor current is generated through electromagnetic induction.
Both machines use magnetic forces to produce torque, but the way electrical energy reaches their rotating components is different.
For a more detailed explanation of the squirrel-cage mechanism, see How a Squirrel-Cage Rotor Produces Torque in an Induction Motor.
08A concise HSC explanation
If an exam question asks you to explain how energy is transferred across the air gap of an induction motor, connect these four ideas:
- Three-phase alternating currents in the stator produce a rotating magnetic field.
- This field crosses the air gap and induces an EMF and current in the rotor conductors through electromagnetic induction.
- The induced rotor current interacts with the stator magnetic field, producing forces and electromagnetic torque.
- Electromagnetic energy is transferred across the air gap and converted into mechanical energy at the shaft, with some energy dissipated through losses.
The key distinction is that the rotor receives energy through electromagnetic coupling, not through a direct electrical connection.
09Questions and solutions
Question 1
A four-pole induction motor is connected to a 50 Hz supply. Its rotor rotates at 1482 rpm.
Calculate:
a) The synchronous speed.
b) The percentage slip.
c) The frequency of the induced rotor current.
Explain why the rotor current frequency is lower than the supply frequency.
Solution 1
The synchronous speed is 1500 rpm, the slip is 1.2%, and the rotor current frequency is 0.60 Hz.
Part a: Synchronous speed
\[ n_s=\frac{120f_s}{P} \]
\[ n_s=\frac{120\times50}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
Part b: Percentage slip
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1500-1482}{1500} \]
\[ s=0.012 \]
Therefore:
\[ \boxed{s=1.2\%} \]
Part c: Rotor current frequency
\[ f_r=sf_s \]
\[ f_r=0.012\times50 \]
\[ \boxed{f_r=0.60\text{ Hz}} \]
The rotor current frequency is lower because the rotor rotates in the same direction as the magnetic field.
The rotor therefore experiences the rotating magnetic field at a relative speed much smaller than the field’s full synchronous speed.
Question 2
A six-pole induction motor operates on a 50 Hz supply. Its rotor speed is 955 rpm.
The motor produces a shaft torque of 5.0 N m and receives 600 W of real electrical input power.
Calculate:
a) The synchronous speed.
b) The percentage slip.
c) The rotor current frequency.
d) The mechanical output power.
e) The motor’s efficiency and total input-to-output power difference.
Explain why the total power difference cannot be identified as the air-gap power.
Solution 2
The synchronous speed is 1000 rpm, the slip is 4.5%, the rotor current frequency is 2.25 Hz, and the shaft output is approximately 500 W. The efficiency is 83.3%, with approximately 100 W of total losses.
Part a: Synchronous speed
\[ n_s=\frac{120f_s}{P} \]
\[ n_s=\frac{120\times50}{6} \]
\[ \boxed{n_s=1000\text{ rpm}} \]
Part b: Percentage slip
\[ s=\frac{1000-955}{1000} \]
\[ s=0.045 \]
\[ \boxed{s=4.5\%} \]
Part c: Rotor current frequency
\[ f_r=sf_s \]
\[ f_r=0.045\times50 \]
\[ \boxed{f_r=2.25\text{ Hz}} \]
Part d: Mechanical output power
First calculate angular velocity:
\[ \omega=\frac{2\pi n_r}{60} \]
\[ \omega=\frac{2\pi\times955}{60} \]
\[ \omega=100.01\text{ rad/s} \]
Now calculate shaft power:
\[ P_{\text{shaft}}=\tau\omega \]
\[ P_{\text{shaft}}=5.0\times100.01 \]
\[ \boxed{P_{\text{shaft}}\approx500\text{ W}} \]
Part e: Efficiency and total losses
Efficiency is:
\[ \eta=\frac{P_{\text{shaft}}}{P_{\text{in}}}\times100 \]
\[ \eta=\frac{500}{600}\times100 \]
\[ \boxed{\eta=83.3\%} \]
The total input-to-output power difference is:
\[ P_{\text{difference}}=600-500 \]
\[ \boxed{P_{\text{difference}}=100\text{ W}} \]
This 100 W includes all the losses between electrical input and mechanical shaft output.
It includes stator winding losses, magnetic core losses, rotor heating, and mechanical losses.
It is not the air-gap power because some of the input power is lost before reaching the rotor, while further losses occur after energy crosses the gap.
Question 3
An investigation uses the same type of induction motor test rig described earlier.
The motor has a four-pole stator connected to a 50 Hz supply. Its squirrel-cage rotor has no electrical leads.
At a steady operating condition, the following measurements are recorded:
- Real electrical input power: 420 W
- Rotor speed: 1460 rpm
- Shaft torque: 2.2 N m
a) Calculate the mechanical output power at the shaft.
b) Calculate the slip and rotor current frequency.
c) Explain how the measurements support the conclusion that energy is transferred across the air gap.
d) A student claims that the difference between electrical input and shaft output is the air-gap power. Explain why this is incorrect.
Solution 3
The shaft output power is approximately 336 W, the slip is 2.67%, and the rotor current frequency is approximately 1.33 Hz. The measurements support electromagnetic energy transfer, but the input-to-output difference is not the air-gap power.
Part a: Mechanical output power
First calculate angular velocity:
\[ \omega=\frac{2\pi n_r}{60} \]
\[ \omega=\frac{2\pi\times1460}{60} \]
\[ \omega=152.89\text{ rad/s} \]
Then:
\[ P_{\text{shaft}}=\tau\omega \]
\[ P_{\text{shaft}}=2.2\times152.89 \]
\[ \boxed{P_{\text{shaft}}\approx336\text{ W}} \]
Part b: Slip and rotor current frequency
The synchronous speed is:
\[ n_s=\frac{120\times50}{4} \]
\[ n_s=1500\text{ rpm} \]
Therefore:
\[ s=\frac{1500-1460}{1500} \]
\[ \boxed{s=0.0267=2.67\%} \]
Rotor current frequency:
\[ f_r=0.0267\times50 \]
\[ \boxed{f_r\approx1.33\text{ Hz}} \]
Part c: Evidence of energy transfer
The rotor produces 336 W of mechanical output despite having no direct electrical connection to the stator.
There is also no direct mechanical contact between the stator and rotor.
The rotating magnetic field must therefore provide the electromagnetic coupling that transfers energy to the rotor.
The induced rotor current then interacts with the magnetic field to produce the torque required to deliver mechanical power.
Part d: Why the difference is not air-gap power
The total input-to-output difference is:
\[ 420-336=84\text{ W} \]
However, this 84 W includes all the motor’s losses.
Some energy is lost in the stator before crossing the gap. Further energy is lost through rotor heating and mechanical friction.
The air-gap power must therefore be greater than the shaft output but less than the electrical input:
\[ P_{\text{shaft}}<P_g<P_{\text{in}} \]
The measurements demonstrate energy conversion, but additional loss measurements would be required to determine the air-gap power.
Question 4
Two motors have four-pole stators connected to a 50 Hz supply.
Both motors are reported to rotate steadily at exactly 1500 rpm while delivering non-zero shaft torque.
- Motor A is a squirrel-cage induction motor.
- Motor B is a permanent-magnet synchronous motor.
Assume the speed measurements are exact.
A student argues that neither motor can produce torque because both rotors are moving at synchronous speed.
Evaluate this statement. Explain how the two motors differ in their rotor excitation and torque production.
Briefly explain how a brushed DC motor differs from both.
Solution 4
The student’s conclusion is incorrect for the permanent-magnet synchronous motor, but the stated operating condition is not possible for an ideal induction motor under a non-zero steady load.
Both stators produce a rotating magnetic field with synchronous speed:
\[ n_s=\frac{120\times50}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
Motor A: Squirrel-cage induction motor
The rotor receives its current through electromagnetic induction.
At exactly 1500 rpm, the rotor and stator magnetic field have no relative rotational speed.
Therefore, in the ideal fundamental-field model:
- The flux linking the rotor circuits does not change due to relative motion.
- No rotor EMF is induced.
- No sustained induction current is produced.
- No induction torque is available.
Consequently, the induction motor cannot maintain a non-zero load torque at exactly synchronous speed.
If it is reported to be doing so, the operating information is inconsistent with the ideal induction-motor model. An external mechanical drive could hold it at that speed, but the induction mechanism would not be supplying the load torque.
Motor B: Permanent-magnet synchronous motor
This motor has a different source of rotor magnetic field.
Its permanent magnets establish the rotor field independently of induced rotor current.
The rotating stator field interacts with the permanent-magnet field to produce torque.
The rotor can therefore remain at synchronous speed while delivering mechanical power.
Its torque depends on the angular displacement between the stator and rotor magnetic fields.
Zero slip does not mean zero torque for this type of motor.
Brushed DC motor
A brushed DC motor receives current directly through brushes and a commutator.
The current enters the rotating armature, and the motor effect produces forces on its conductors.
Unlike an induction motor, it does not rely on slip to induce its rotor current.
The important difference is the source of rotor excitation, not simply whether the machine contains a magnetic field.
Question 5
A four-pole induction machine is connected to a 50 Hz electrical grid.
The positive direction of rotation is defined as the direction of the stator’s rotating magnetic field.
A mechanical drive initially forces the rotor to rotate at 1530 rpm. The external drive is then disconnected, but a constant mechanical load remains attached to the shaft.
The rotor slows down, passes through 1500 rpm, and eventually settles at 1470 rpm.
Assume:
- The stator remains connected to the grid throughout.
- The rotor slows continuously rather than changing speed instantaneously.
- The 1470 rpm condition is a stable motoring operating point.
- The ideal fundamental-field model applies.
Answer the following:
a) Calculate the signed slip at 1530 rpm, 1500 rpm, and 1470 rpm.
b) Calculate the magnitude of the rotor current frequency at each speed.
c) Identify whether the machine is operating as a motor or generator at 1530 rpm and 1470 rpm. Explain the direction of energy transfer across the air gap in each case.
d) Explain why the rotor does not stop when it reaches exactly 1500 rpm.
e) A student notices that the rotor current frequency has the same magnitude at 1530 rpm and 1470 rpm. They conclude that energy must flow in the same direction in both conditions. Explain the mistake.
Solution 5
The machine operates as a generator above synchronous speed and as a motor below synchronous speed. At exactly synchronous speed, the ideal induction mechanism produces no torque, but the rotor continues moving because of its rotational inertia.
This question tests an important distinction: slip determines the relative motion responsible for induction, while the sign of slip helps identify the direction of energy transfer.
Part a: Calculate signed slip
First calculate synchronous speed:
\[ n_s=\frac{120\times50}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
Use the signed slip equation:
\[ s=\frac{n_s-n_r}{n_s} \]
At 1530 rpm:
\[ s=\frac{1500-1530}{1500} \]
\[ \boxed{s=-0.020=-2.0\%} \]
At 1500 rpm:
\[ s=\frac{1500-1500}{1500} \]
\[ \boxed{s=0} \]
At 1470 rpm:
\[ s=\frac{1500-1470}{1500} \]
\[ \boxed{s=+0.020=+2.0\%} \]
The negative slip at 1530 rpm indicates that the rotor is rotating faster than the stator’s magnetic field.
Part b: Calculate rotor current frequency
The magnitude of the rotor current frequency is:
\[ f_r=|s|f_s \]
At 1530 rpm:
\[ f_r=0.020\times50 \]
\[ \boxed{f_r=1.0\text{ Hz}} \]
At 1500 rpm:
\[ f_r=0\times50 \]
\[ \boxed{f_r=0\text{ Hz}} \]
At 1470 rpm:
\[ f_r=0.020\times50 \]
\[ \boxed{f_r=1.0\text{ Hz}} \]
The results can be summarised as:
| Rotor speed | Signed slip | Rotor current frequency |
|---|---|---|
| 1530 rpm | -2.0% | 1.0 Hz |
| 1500 rpm | 0% | 0 Hz |
| 1470 rpm | +2.0% | 1.0 Hz |
Part c: Identify the direction of energy transfer
At 1530 rpm, the rotor is moving faster than the rotating magnetic field.
The machine is operating as an induction generator.
The external mechanical drive supplies energy to the rotor. Electromagnetic interaction transfers this energy across the air gap towards the stator, where electrical energy is delivered to the grid.
The electromagnetic torque opposes the rotor’s motion, resisting the external mechanical drive.
At 1470 rpm, the rotating magnetic field moves faster than the rotor.
The machine is operating as an induction motor.
Electrical energy enters through the stator and crosses the air gap electromagnetically. The induced rotor current produces torque in the direction of the rotating field, allowing the rotor to drive the mechanical load.
The direction of energy transfer has reversed.
Part d: Why doesn’t the rotor stop at synchronous speed?
At exactly 1500 rpm, the rotor and stator field have no relative rotational speed.
Therefore, the ideal fundamental-field model predicts no induced rotor EMF, no sustained induced rotor current, and no induction torque.
However, zero torque does not mean zero rotational speed.
The rotor has rotational inertia. It does not lose its angular velocity instantaneously when the electromagnetic torque becomes zero.
The mechanical load continues to oppose the rotor’s motion, so the rotor decelerates and passes below synchronous speed.
Once it moves below 1500 rpm, positive slip develops again.
This allows rotor current and motoring torque to reappear.
Eventually, the motor can reach a steady operating condition at 1470 rpm, where electromagnetic torque balances the mechanical load and rotational losses.
Part e: Why equal rotor frequencies do not mean equal energy-flow directions
The student’s mistake is treating rotor current frequency as the only factor determining energy transfer.
At both 1530 rpm and 1470 rpm, the magnitude of slip is 2%.
Consequently, the rotor current frequency has the same magnitude of 1 Hz.
However, the sign of slip is different.
At 1530 rpm, the rotor is faster than the magnetic field, and the machine operates as a generator.
At 1470 rpm, the rotor is slower than the magnetic field, and the machine operates as a motor.
The relative direction of the rotor and rotating field changes the electromagnetic torque direction and therefore the direction of real power transfer.
This is the important distinction: the magnitude of slip determines the magnitude of the relative frequency, but the sign of slip helps identify the direction of energy conversion.
An induction motor’s air gap is therefore much more than an empty space between two rotating components. It is the region through which electromagnetic energy is transferred, allowing the stationary stator to deliver mechanical power through a rotor that has no direct electrical connection to the supply.