Isotope Dilution Analysis: Calculating Unknown Quantities
Learn how isotope dilution analysis uses an enriched isotope standard and measured isotope ratios to determine the unknown amount of an element. Builds on Year 11 quantitative chemistry with worked calculations, experimental applications, and the method's limitations.
A water sample contains a tiny amount of a metal. You add reagents to prepare it for analysis, transfer it between containers, and remove unwanted substances. Somewhere along the way, a small amount of the metal is lost. How can you determine how much was present in the original sample if you cannot measure what disappeared?
One solution is to add a known amount of the same element before processing the sample. The catch is that the added element has a different mixture of isotopes. By measuring how the isotope ratio changes after mixing, you can calculate how much of the original element was present.
This is called isotope dilution analysis.
This article goes beyond the required content of the NSW Chemistry 11-12 Syllabus (2025). Year 11 Quantitative Chemistry provides the prerequisite knowledge, particularly preparing primary standard solutions and calculating dilutions. Isotope dilution itself is an extension topic, not an assessment requirement. The 2025 syllabus is scheduled for implementation from 2028, as outlined by NESA.
01Why add an isotope spike?
Imagine you are trying to determine the amount of a particular element in an environmental sample.
A conventional analytical method might measure the signal produced by that element and compare it with signals from solutions of known concentration.
However, several things can affect the measurement:
- Some analyte may be lost during sample preparation.
- Other substances in the sample may interfere with the instrument.
- Instrument sensitivity may change during analysis.
- The sample may be too dilute for a reliable direct measurement.
A calibration curve can help with instrumental measurements, but it cannot automatically tell you how much analyte was lost before the sample reached the instrument.
Isotope dilution takes a different approach.
Instead of relying only on the strength of the instrument’s signal, it uses the relative amounts of different isotopes in the sample.
First, what is an isotope?
Isotopes are atoms of the same element with different numbers of neutrons.
For example, carbon-12 and carbon-13 both contain six protons. However, carbon-12 has six neutrons, while carbon-13 has seven.
They are both carbon, so they have almost identical chemical behaviour. Their different masses allow an instrument such as a mass spectrometer to distinguish them.
This is the important feature: isotopes can be chemically very similar while remaining distinguishable by their masses.
The chemical similarity is not absolutely perfect. Small isotope effects can occur, but for the simplified model developed here, we treat the isotopes as behaving identically during chemical processing.
The enriched spike
An isotope spike is a measured amount of an element with a deliberately altered isotopic composition.
Suppose an element has two isotopes:
- A lighter isotope, L.
- A heavier isotope, H.
Imagine the original sample contains:
- 80% L
- 20% H
An enriched spike of the same element might contain:
- 10% L
- 90% H
The spike is enriched in the heavier isotope because it contains a much greater proportion of H than the original sample.
When these materials are mixed, the final mixture contains contributions from both sources.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
What would happen if you added more enriched spike?
The mixture would move closer to the spike’s isotopic composition. If you added more original sample instead, it would move closer to the sample’s starting composition.
This is the central idea behind isotope dilution: the final isotope ratio depends on how much original analyte was present relative to the known amount of enriched spike.
A useful analogy is mixing two batches of identical marbles, one with a blue marking and one with a red marking. If you know the proportion of each colour in both batches, you can use the final colour proportions to work backwards and estimate how much came from each batch.
The analogy has a limit. Real atoms are not coloured or physically marked. Their different masses allow a mass spectrometer to distinguish them.
02The Year 11 quantitative chemistry connection
Before working with isotope ratios, it helps to revisit the quantitative chemistry you already know.
The 2025 NSW Chemistry syllabus includes preparing a primary standard solution and performing a dilution with a calculated concentration.
These skills establish how chemists prepare solutions with known quantities of dissolved substances.
Preparing a primary standard solution
A primary standard is a highly pure, stable substance with a known composition that can be accurately weighed.
Suppose you weigh a known mass of a suitable solid and dissolve it in a known volume of solution.
The first step is calculating the amount of substance:
\[ n=\frac{m}{M} \]
where:
- \(n\) is the amount of substance in moles (mol).
- \(m\) is the mass of the substance in grams (g).
- \(M\) is its molar mass in grams per mole (g mol\(^{-1}\)).
You can then calculate its concentration:
\[ c=\frac{n}{V} \]
where:
- \(c\) is the molar concentration in mol L\(^{-1}\).
- \(n\) is the amount of solute in moles.
- \(V\) is the final solution volume in litres.
The result is a solution with a calculated concentration.
Performing a dilution
Suppose you have a solution with a known concentration and need to prepare a less concentrated solution.
You transfer a measured volume of the original solution into a larger volumetric flask and add solvent.
The amount of dissolved substance stays constant during an ordinary dilution.
This gives the familiar equation:
\[ c_1V_1=c_2V_2 \]
where:
- \(c_1\) is the initial concentration.
- \(V_1\) is the initial solution volume transferred.
- \(c_2\) is the final concentration.
- \(V_2\) is the final solution volume.
The subscripts 1 and 2 refer to the initial and final solutions, respectively.
How isotope dilution is different
Isotope dilution also involves mixing solutions, but the purpose is different.
| Ordinary dilution | Isotope dilution |
|---|---|
| Adds solvent to reduce concentration | Adds an enriched isotope standard |
| Changes concentration | Changes isotope composition |
| Conserves the amount of solute | Conserves the amounts of each isotope during mixing |
| Uses concentration and volume measurements | Uses known spike quantities and measured isotope ratios |
Ordinary dilution tells you how concentration changes when solvent is added.
Isotope dilution tells you how much unknown analyte was present by observing how a known isotope mixture changes the final isotope ratio.
The Year 11 skills still matter. You need to know how to prepare and quantify the enriched standard accurately before using it.
One important distinction: an enriched isotope spike is not automatically a primary standard solution. Its concentration, purity, and isotopic composition must be independently characterised.
03How an isotope dilution experiment works
The method follows a sequence of sample preparation and measurement.
1. Measure the original sample
A known mass or volume of the unknown sample is selected.
The amount of the target element is unknown. Its original isotopic composition, however, must be known or independently determined.
For a naturally occurring element, scientists may use an established natural isotopic composition where appropriate. If the sample has an unusual isotopic composition, it must not simply be assumed to have the usual natural abundance.
2. Add the enriched isotope spike
A known amount of enriched standard is added to the sample.
The spike contains the same target element, but with a deliberately different isotope ratio.
Both sources now contribute atoms to the same mixture.
3. Allow isotopic equilibration
This is one of the most important stages.
The sample and spike must mix sufficiently for their isotopes to become part of the same chemical pool.
This is called isotopic equilibration.
For example, if the target is a metal, the original metal and the enriched spike must be brought into a common dissolved form before the mixture can be treated as a single homogeneous isotope pool.
Why is this necessary?
Suppose some of the original metal remains trapped in undissolved particles while the spike is dissolved in solution.
The spike cannot track the undissolved metal because those atoms have not entered the same pool.
The measured isotope ratio would then represent only the portion that successfully equilibrated.
4. Prepare the mixture for measurement
The mixture may undergo chemical separation to remove substances that interfere with the mass spectrometer.
This can involve specialised sample preparation and separation techniques.
The important point is that these steps occur after the spike has been added and the isotopes have equilibrated.
An advantage of the method is that non-selective losses after equilibration do not change the isotope ratio.
Imagine that 10% of the combined mixture is lost during purification. If the loss affects both isotopes equally, their relative proportions remain unchanged.
The instrument can therefore still provide information about the amount originally present in the equilibrated mixture.
This is one of the major advantages of isotope dilution analysis.
5. Measure the isotope ratio using mass spectrometry
A mass spectrometer separates ions according to their mass-to-charge ratio, commonly written as \(m/z\).
In simplified terms, the process works as follows:
- The prepared sample enters an ion source, where atoms or molecules are converted into ions.
- The ions enter a mass analyser.
- Electric or magnetic fields separate ions according to their mass-to-charge ratios.
- A detector measures the signals associated with the selected isotopes.
- The corrected signal ratio is used to determine the isotope ratio.
For example, the instrument might measure the relative abundance of two isotopes of calcium.
The important measurement is not simply the total calcium signal. It is the ratio between the signals associated with the selected isotopes.
What should the experiment show?
The measured isotope ratio should fall between the original sample ratio and the spike ratio, assuming the spike is enriched in one of the selected isotopes and no significant interference is present.
For example:
- Original sample: heavy-to-light ratio of 1:4.
- Enriched spike: heavy-to-light ratio of 9:1.
- Final mixture: an intermediate ratio.
If the final ratio is closer to the spike ratio, the spike contributed a relatively large proportion of the total element.
If it is closer to the original sample ratio, the original sample contributed a relatively large proportion.
This is the evidence that allows us to calculate the unknown quantity.
04The mathematics of isotope dilution
We can now build a mathematical model without needing advanced university-level equations.
For the moment, assume the element has only two isotopes: a light isotope L and a heavy isotope H.
We will use the following quantities:
| Symbol | Meaning |
|---|---|
| \(n_s\) | Unknown moles of element in the original sample |
| \(n_p\) | Known moles of element in the enriched spike |
| \(R_s\) | Original sample’s heavy-to-light isotope ratio |
| \(R_p\) | Spike’s heavy-to-light isotope ratio |
| \(R_m\) | Measured heavy-to-light ratio in the mixture |
| \(x_s\) | Heavy-isotope fraction in the sample |
| \(x_p\) | Heavy-isotope fraction in the spike |
| \(x_m\) | Heavy-isotope fraction in the mixture |
All three isotope fractions are dimensionless.
Step 1: Convert the isotope ratio into an isotope fraction
A mass spectrometer measures an isotope ratio.
We define the ratio as:
\[ R=\frac{n_H}{n_L} \]
where:
- \(n_H\) is the amount of the heavy isotope.
- \(n_L\) is the amount of the light isotope.
The heavy-isotope fraction is the amount of heavy isotope divided by the total amount of both isotopes:
\[ x=\frac{n_H}{n_H+n_L} \]
Substituting the isotope ratio gives:
\[ x=\frac{R}{1+R} \]
This conversion is important because isotope fractions, rather than isotope ratios, can be combined using a straightforward weighted average.
For example, if the heavy-to-light ratio is 1:4:
\[ R=\frac{1}{4}=0.25 \]
Therefore:
\[ x=\frac{0.25}{1.25}=0.20 \]
The sample contains 20% heavy isotope.
Step 2: Apply the mixing principle
The total amount of heavy isotope in the final mixture comes from two sources:
- The original sample.
- The enriched spike.
The total number of moles of heavy isotope is therefore:
\[ n_H=n_sx_s+n_px_p \]
The total amount of the element in the mixture is:
\[ n_{\text{total}}=n_s+n_p \]
Consequently, the heavy-isotope fraction in the mixture is:
\[ x_m=\frac{n_sx_s+n_px_p}{n_s+n_p} \]
This is a weighted average.
The contribution from each source depends on how much of the element it contains.
Step 3: Rearrange to calculate the unknown amount
Rearranging the mixing equation to make \(n_s\) the subject gives:
\[ \boxed{ n_s=n_p\frac{x_p-x_m}{x_m-x_s} } \]
This is the simplified isotope dilution equation.
It tells us that we can determine the unknown amount of analyte using:
- The known amount of spike.
- The heavy-isotope fraction of the original sample.
- The heavy-isotope fraction of the spike.
- The measured heavy-isotope fraction of the mixture.
The important feature is that the unknown amount can be calculated without directly measuring the original sample’s absolute signal.
A note about real elements
Many elements have more than two stable isotopes.
In real isotope dilution mass spectrometry, scientists can select two isotopes for measurement while accounting for the actual isotopic abundances of the sample and spike.
A more general mixing relationship is:
\[ R_m= \frac{n_sf_{s,H}+n_pf_{p,H}} {n_sf_{s,L}+n_pf_{p,L}} \]
Here:
- \(f_{s,H}\) and \(f_{s,L}\) are the fractions of the selected heavy and light isotopes in the original sample.
- \(f_{p,H}\) and \(f_{p,L}\) are the corresponding fractions in the spike.
- \(n_s\) and \(n_p\) are the total amounts of the element in each source.
- \(R_m\) is the measured heavy-to-light ratio.
The same mass-balance principle still applies.
The two-isotope model is a teaching simplification, not a complete description of every real isotope dilution experiment.
05Worked example: Calculate the unknown concentration
A 10.00 mL sample contains an element with two isotopes, heavy H and light L.
The original sample has a heavy-to-light isotope ratio of 0.250.
A spike containing 2.00 μmol of the same element is added. Its heavy-to-light ratio is 9.00.
After equilibration and preparation, the measured heavy-to-light ratio of the mixture is 1.00.
Calculate the original concentration of the element in the sample.
Step 1
\[ x_s=\frac{R_s}{1+R_s} \]
Substitute the given ratio:
\[ x_s=\frac{0.250}{1.250} =0.200 \]
The original sample contains 20.0% heavy isotope.
Step 2
\[ x_p=\frac{R_p}{1+R_p} \]
\[ x_p=\frac{9.00}{10.00} =0.900 \]
The spike contains 90.0% heavy isotope.
Step 3
\[ x_m=\frac{R_m}{1+R_m} \]
\[ x_m=\frac{1.00}{2.00} =0.500 \]
The mixture contains 50.0% heavy isotope.
Step 4
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
\[ n_s=2.00 \frac{0.900-0.500}{0.500-0.200} \]
\[ n_s=2.00\times\frac{0.400}{0.300} \]
\[ n_s=2.67\ \mu\text{mol} \]
The original 10.00 mL sample contained 2.67 μmol of the element.
Step 5
Use:
\[ c=\frac{n}{V} \]
Convert the volume:
\[ 10.00\text{ mL}=0.01000\text{ L} \]
Therefore:
\[ c=\frac{2.67\times10^{-6}}{0.01000} \]
\[ c=2.67\times10^{-4}\text{ mol L}^{-1} \]
Final answer
\[ \boxed{c=0.267\text{ mmol L}^{-1}} \]
The original sample had a concentration of 0.267 mmol L\(^{-1}\).
Notice that we never needed to measure the absolute number of original sample atoms directly. We inferred their amount from the change in isotope composition.
06Worked example: Account for an ordinary dilution as well
A 5.00 mL environmental sample is diluted to 50.00 mL.
A 10.00 mL aliquot of the diluted sample is then mixed with an enriched isotope spike containing 1.50 μmol of the target element.
The isotope fractions are:
- Original sample: \(x_s=0.20\).
- Spike: \(x_p=0.95\).
- Measured mixture: \(x_m=0.60\).
After complete isotopic equilibration, a purification stage removes 20.0% of the combined element from the mixture. Assume this loss affects both isotopes equally.
Calculate the original concentration of the element in the environmental sample.
Step 1
We know:
\[ n_p=1.50\ \mu\text{mol} \]
\[ x_s=0.20 \]
\[ x_p=0.95 \]
\[ x_m=0.60 \]
We need to calculate the original amount of analyte in the 10.00 mL aliquot.
Step 2
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
Substitute:
\[ n_s=1.50 \frac{0.95-0.60}{0.60-0.20} \]
\[ n_s=1.50\times\frac{0.35}{0.40} \]
\[ n_s=1.3125\ \mu\text{mol} \]
The 10.00 mL aliquot originally contained 1.3125 μmol of the target element.
Step 3
The original sample was diluted from 5.00 mL to 50.00 mL.
The dilution factor is:
\[ DF=\frac{50.00}{5.00}=10.0 \]
However, the isotope dilution calculation was performed on only 10.00 mL of the diluted solution.
The full 50.00 mL solution contains five times the amount in that aliquot:
\[ n_{\text{original}}= 1.3125\times\frac{50.00}{10.00} \]
\[ n_{\text{original}}=6.5625\ \mu\text{mol} \]
This is the amount originally present in the 5.00 mL environmental sample.
Step 4
\[ c=\frac{n}{V} \]
\[ c=\frac{6.5625\ \mu\text{mol}}{5.00\text{ mL}} \]
\[ c=1.3125\ \mu\text{mol mL}^{-1} \]
Since 1 μmol mL\(^{-1}\) is equivalent to 1 mmol L\(^{-1}\):
\[ \boxed{c=1.31\text{ mmol L}^{-1}} \]
The original environmental sample had a concentration of 1.31 mmol L\(^{-1}\).
What about the 20.0% loss during purification?
We do not apply a recovery correction.
The loss occurred after the sample and spike had fully equilibrated. Both isotopes were lost in the same proportion, so their ratio remained unchanged.
The isotope dilution calculation therefore already gives the amount present before that loss.
However, if the analyte had been lost before the spike was added, the method would not automatically correct for it.
This is an important distinction between ordinary dilution corrections and isotope dilution analysis.
For more practice with ordinary sample dilution, see How to Correct Environmental Analysis for Sample Dilution.
07A real experimental application: Measuring calcium in blood serum
Isotope dilution is not just a theoretical calculation.
The US National Bureau of Standards, now the National Institute of Standards and Technology (NIST), published a reference method for determining calcium concentrations in blood serum in 1972.
The work is documented in NBS Special Publication 260-36.
The analytical problem was to determine calcium accurately in a complex biological sample.
Blood serum contains many substances besides calcium. These substances can interfere with chemical preparation and instrumental measurements.
How the experiment was arranged
The researchers followed a sequence of sample preparation and measurement.
First, they obtained measured portions of the calcium-containing sample.
Next, they added a known amount of a separated calcium isotope. This changed the relative abundance of the calcium isotopes in the mixture.
Then, they chemically treated the serum to remove its organic material and purified the calcium using ion exchange.
Ion exchange is a separation technique in which dissolved ions interact with a material that selectively retains or releases particular ions.
After purification, the calcium was prepared in a suitable chemical form and loaded onto heated rhenium filaments.
The filaments were used in a thermal ionisation mass spectrometer.
Finally, heating produced calcium ions, which entered a magnetic-sector mass analyser. The analyser separated the ions according to their mass-to-charge ratios, and Faraday cup collectors measured their signals.
The researchers measured the relative amounts of calcium-40 and calcium-44.
What did the researchers expect?
If the known isotope spike mixed completely with the calcium in the sample, the final calcium isotope ratio should change in a predictable way.
The extent of that change would depend on the relative amounts of calcium from the original serum and the enriched spike.
The researchers could then calculate the original calcium concentration using the measured isotope ratio and the known spike quantity.
Their experiments included prepared calcium solutions of known concentrations. Agreement between isotope dilution results from different aliquots provided a check on the reproducibility of the method.
What did they discover about interference?
An important complication appeared when the researchers tested solutions containing additional sodium and potassium to simulate serum conditions.
Potassium introduced an interference associated with potassium-40 at mass 40, where the calcium-40 measurement was being made.
The researchers therefore used ion exchange to remove potassium before the isotope measurements.
This is an important lesson.
Isotope dilution can reduce the effects of many common measurement problems, but it does not make every interference disappear. A separate substance producing a signal at one of the measured isotope masses can still distort the ratio.
The experiment demonstrated both the strength of isotope dilution and the need for careful sample preparation.
08When does isotope dilution work, and when does it fail?
Isotope dilution is powerful because the spike provides an internal reference that travels through the analytical process with the original analyte.
However, several conditions must be satisfied.
1. The spike quantity must be known
The amount of element in the spike must be accurately characterised.
If the spike concentration is incorrect, the calculated amount in the original sample will also be incorrect.
This is why preparing and characterising reference solutions is so important.
2. The original isotope composition must be known
The calculation requires knowledge of the starting isotopic composition of the sample.
It is not always safe to assume that every sample has exactly the same natural isotope abundance.
Some samples have unusual isotope compositions because of their geological origin, processing history, or isotope fractionation.
If the wrong starting ratio is used, the calculated analyte quantity will be biased.
3. The spike and analyte must fully equilibrate
This is arguably the most important experimental requirement.
Once both sources have entered the same chemical pool, they can generally be lost together without changing their isotope ratio.
However, if part of the original analyte remains undissolved or chemically inaccessible, the spike cannot automatically account for that portion.
The result may represent only the amount that successfully mixed with the spike.
4. Isotopic interference must be controlled
The mass spectrometer must distinguish the selected isotope signals accurately.
An unwanted ion with a similar mass-to-charge ratio can interfere with one of the measurements.
Chemical separation, instrument resolution, and appropriate corrections help control these problems.
5. The isotopes must behave sufficiently similarly
Isotopes have almost identical chemical properties, but small differences can occur because of their different masses.
If a preparation step separates isotopes to a significant extent, the measured isotope ratio may change for reasons unrelated to the amount of spike added.
High-precision isotope dilution methods account for these effects where necessary.
6. Contamination must be minimised
Suppose the sample contains a very small amount of the target element.
If laboratory equipment or reagents introduce additional amounts of that element, the final isotope ratio may be altered.
This is called contamination or a sample blank contribution.
For trace analysis, even a small contamination can produce a significant error.
Modern isotope dilution mass spectrometry methods therefore require careful control of spike purity, equilibration, instrumental calibration, and contamination. These considerations are discussed in NIST Special Publication 1209 and a 2024 review in the Journal of Analytical Atomic Spectrometry.
09Questions and solutions
The following questions use the simplified two-isotope model unless otherwise stated. Treat all numerical data as hypothetical teaching data.
Question 1
A sample contains an element with two stable isotopes, H and L.
Its initial heavy-to-light isotope ratio is 0.250.
A spike containing 1.00 μmol of the element has a heavy-to-light ratio of 4.00. After mixing, the measured heavy-to-light ratio is 1.00.
The original sample volume was 20.0 mL.
Calculate the original concentration of the element in the sample.
Solution 1
The original concentration is 0.0500 mmol L\(^{-1}\).
First, convert the three isotope ratios into heavy-isotope fractions.
For the sample:
\[ x_s=\frac{0.250}{1.250}=0.200 \]
For the spike:
\[ x_p=\frac{4.00}{5.00}=0.800 \]
For the mixture:
\[ x_m=\frac{1.00}{2.00}=0.500 \]
Now apply the isotope dilution equation:
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
\[ n_s=1.00\frac{0.800-0.500}{0.500-0.200} \]
\[ n_s=1.00\ \mu\text{mol} \]
Calculate the concentration:
\[ c=\frac{1.00\ \mu\text{mol}}{20.0\text{ mL}} \]
\[ c=0.0500\ \mu\text{mol mL}^{-1} \]
Therefore:
\[ \boxed{c=0.0500\text{ mmol L}^{-1}} \]
The original sample contained 1.00 μmol of the element in 20.0 mL.
Question 2
An analyst adds 2.40 μmol of enriched isotope spike to an unknown sample.
The isotope fractions are:
- Sample: \(x_s=0.25\).
- Spike: \(x_p=0.85\).
- Final mixture: \(x_m=0.55\).
The sample and spike are allowed to equilibrate completely. During subsequent purification, 25.0% of the combined element is lost.
Calculate the original amount of analyte in the sample.
A laboratory technician argues that the calculated amount must be multiplied by \(1/0.75\) to correct for the 25.0% loss.
Is the technician correct? Would the conclusion change if the loss occurred before the spike was added?
Solution 2
The original sample contained 2.40 μmol of analyte, and the technician’s proposed recovery correction is unnecessary.
First, calculate the original sample amount:
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
Substitute:
\[ n_s=2.40\frac{0.85-0.55}{0.55-0.25} \]
\[ n_s=2.40\times\frac{0.30}{0.30} \]
\[ \boxed{n_s=2.40\ \mu\text{mol}} \]
Why don’t we correct for the 25.0% loss?
The loss occurred after complete isotopic equilibration.
Both the original analyte and enriched spike were part of the same homogeneous mixture. If 25.0% of the combined material is lost non-selectively, both isotopes are reduced in the same proportion.
Their ratio therefore remains unchanged.
The measured ratio still contains the information needed to calculate the original amount of analyte.
The situation would be different if the analyte were lost before the spike was added.
In that case, the missing analyte would never have mixed with the enriched isotope. The spike could not track that earlier loss, and the calculated amount would underestimate the amount originally present.
The timing of spike addition is therefore critical.
Question 3
A sample has an independently measured initial heavy-to-light isotope ratio of \(1/3\).
An analyst instead assumes that its ratio is 0.250, based on a reference value for a different sample.
The enriched spike contains 1.20 μmol of the element and has a heavy-to-light isotope ratio of 19.0.
After mixing, the measured mixture ratio is 1.50.
Calculate:
(a) The correct original amount of analyte using the independently measured sample ratio.
(b) The amount calculated using the incorrect assumed sample ratio of 0.250.
(c) The percentage error caused by using the incorrect isotope composition.
Solution 3
The correct amount is 1.20 μmol. Using the incorrect isotope composition gives 1.05 μmol, an underestimate of 12.5%.
Part (a): Correct calculation
Convert the actual sample ratio into a heavy-isotope fraction:
\[ x_s=\frac{1/3}{1+1/3} \]
\[ x_s=0.250 \]
For the spike:
\[ x_p=\frac{19.0}{20.0}=0.950 \]
For the mixture:
\[ x_m=\frac{1.50}{2.50}=0.600 \]
Substitute:
\[ n_s=1.20\frac{0.950-0.600}{0.600-0.250} \]
\[ n_s=1.20\times\frac{0.350}{0.350} \]
\[ \boxed{n_s=1.20\ \mu\text{mol}} \]
Part (b): Incorrect calculation
The analyst assumes the original sample ratio was 0.250.
The corresponding heavy-isotope fraction is:
\[ x_s=\frac{0.250}{1.250}=0.200 \]
Using this incorrect value:
\[ n_s=1.20\frac{0.950-0.600}{0.600-0.200} \]
\[ n_s=1.20\times\frac{0.350}{0.400} \]
\[ \boxed{n_s=1.05\ \mu\text{mol}} \]
Part (c): Percentage error
Use:
\[ \%\text{ error}= \frac{\text{calculated}-\text{correct}} {\text{correct}}\times100 \]
\[ =\frac{1.05-1.20}{1.20}\times100 \]
\[ \boxed{-12.5\%} \]
The negative sign indicates an underestimate.
The tempting assumption was that the sample had the standard reference isotope composition. However, the actual sample had a different starting ratio.
The isotope dilution equation is sensitive to this starting composition. Even if the spike quantity and final isotope ratio are measured accurately, an incorrect initial isotope composition produces an incorrect result.
Question 4
An isotope dilution experiment measures calcium using the selected isotopes calcium-40 and calcium-44.
The enriched spike contains a high proportion of calcium-44.
The instrument measures the ratio:
\[ R_m=\frac{\text{signal from calcium-44}} {\text{signal from calcium-40}} \]
The sample also contains potassium-40, which produces an unresolved signal at the nominal mass used to measure calcium-40.
Assume the potassium interference adds to the measured calcium-40 signal but does not affect the calcium-44 signal.
Explain:
(a) How the interference changes the measured isotope ratio.
(b) Whether the calculated original calcium amount will be overestimated or underestimated.
(c) How the experimental procedure could be modified to reduce the interference.
Solution 4
The measured calcium-44/calcium-40 ratio will be too low, causing the calculated calcium amount to be overestimated. Ion-exchange separation can reduce the potassium interference.
Part (a): Effect on the isotope ratio
The measured ratio is:
\[ R_m=\frac{I_{44}}{I_{40}} \]
where \(I_{44}\) and \(I_{40}\) are the measured signals for calcium-44 and calcium-40, respectively.
Potassium-40 contributes an additional signal to the denominator.
The denominator becomes artificially larger, while the numerator remains unchanged.
Therefore:
\[ R_m\text{ decreases} \]
The instrument reports a lower calcium-44/calcium-40 ratio than the true ratio.
Part (b): Effect on the calculated amount
A lower measured heavy-to-light ratio corresponds to a lower calculated heavy-isotope fraction \(x_m\).
Recall:
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
If \(x_m\) decreases towards \(x_s\):
- The numerator increases.
- The denominator decreases.
Consequently, the calculated \(n_s\) becomes larger.
The original calcium amount is therefore overestimated.
This conclusion assumes the interference is large enough to affect the measured signal but does not make the ratio fall outside the physically valid mixing range.
Part (c): Reducing the interference
The sample can undergo ion-exchange separation before mass spectrometry.
The separation removes potassium from the calcium-containing solution, reducing the unwanted potassium-40 contribution.
This allows the mass spectrometer to measure the calcium isotope ratio more accurately.
The important lesson is that isotope dilution does not remove the need for appropriate chemical separation. The isotope ratio is only useful if the measured signals genuinely represent the selected isotopes.
Question 5
A laboratory is analysing a 5.00 mL sample containing an unknown amount of an element E.
The element is present in two forms:
- 80.0% of the original E dissolves and becomes available to mix with the isotope spike.
- 20.0% remains trapped in undissolved solid particles and is removed before isotope ratio measurement.
The dissolved portion is mixed completely with an enriched isotope spike.
The following data are recorded:
| Quantity | Value |
|---|---|
| Known amount of spike, \(n_p\) | 1.60 μmol |
| Heavy-isotope fraction in sample, \(x_s\) | 0.20 |
| Heavy-isotope fraction in spike, \(x_p\) | 0.80 |
| Measured heavy-isotope fraction, \(x_m\) | 0.44 |
After equilibration, 25.0% of the combined dissolved element is lost during purification. This loss affects both isotopes equally.
A student argues:
“The isotope dilution method corrects for losses automatically, so the measured result must give the total amount of E in the original sample. The undissolved material and purification loss don’t matter.”
Evaluate this claim.
Calculate:
(a) The original amount of E that entered the equilibrated dissolved pool.
(b) The total original amount of E in the 5.00 mL sample.
(c) Whether a recovery correction for the 25.0% purification loss is necessary.
(d) Whether the original total amount could be determined from the isotope ratio alone if the 80.0% dissolution information were not available.
Solution 5
The original sample contained 3.00 μmol of E. The isotope dilution method determines the 2.40 μmol that entered the equilibrated pool, but it cannot automatically account for the 20.0% that never dissolved.
This question tests the difference between two types of material loss.
One occurs after equilibration and does not change the isotope ratio.
The other occurs before equilibration and cannot be corrected by the spike.
Part (a): Calculate the amount in the equilibrated dissolved pool
Apply the isotope dilution equation:
\[ n_s=n_p\frac{x_p-x_m}{x_m-x_s} \]
Substitute:
\[ n_s=1.60\frac{0.80-0.44}{0.44-0.20} \]
\[ n_s=1.60\times\frac{0.36}{0.24} \]
\[ \boxed{n_s=2.40\ \mu\text{mol}} \]
The dissolved portion of the original sample contained 2.40 μmol of E.
Part (b): Calculate the total original amount
Only 80.0% of the original element entered the dissolved pool.
Therefore:
\[ 0.800\times n_{\text{total}}=2.40 \]
Rearrange:
\[ n_{\text{total}}=\frac{2.40}{0.800} \]
\[ \boxed{n_{\text{total}}=3.00\ \mu\text{mol}} \]
The original 5.00 mL sample contained 3.00 μmol of E.
Part (c): Consider the purification loss
No recovery correction is needed for the 25.0% purification loss.
The loss occurred after complete equilibration.
Both isotopes were present in the same dissolved pool, so losing 25.0% of the combined element did not change their relative proportions.
The measured isotope ratio therefore still gives the amount of analyte that was originally present in the dissolved pool.
Dividing by 0.75 would incorrectly increase the calculated amount.
Part (d): Consider what happens without the dissolution information
The original total amount could not be determined from the isotope ratio alone.
The instrument measures the isotopic composition of the equilibrated dissolved portion. It has no information about how much element remained trapped in the discarded solid.
For example, the same measured isotope ratio could result from:
- A sample containing 3.00 μmol, of which 80.0% dissolved.
- A sample containing 4.00 μmol, of which 60.0% dissolved.
Both would produce 2.40 μmol of dissolved analyte and could produce exactly the same isotope ratio when mixed with the same spike.
The isotope ratio cannot distinguish between these original totals.
The missing information must come from an independent measurement or a validated sample preparation method that demonstrates complete dissolution.
This is the crucial limitation: isotope dilution corrects for non-selective losses after isotopic equilibration, not for analyte that never enters the equilibrated pool.
10Where to go next
The next important decision in quantitative analysis is choosing a method that suits the sample and the type of measurement required.
Ordinary dilution calculations are appropriate when you know how much solution has been diluted and need to recover its original concentration.
Isotope dilution is useful when you need to quantify an analyte using an enriched isotope standard, particularly when sample preparation losses and matrix effects could compromise a direct measurement.
In specialist analytical chemistry, the quality of the result ultimately depends on more than the isotope ratio. The spike concentration, initial isotope composition, completeness of equilibration, and instrumental uncertainty all contribute to the final measurement.
That is where isotope dilution connects to the broader topic of analytical measurement uncertainty: knowing how to calculate a result is only part of knowing how reliable that result actually is.