Evanescent Waves: Fields Beyond Total Internal Reflection
Discover how evanescent waves form during total internal reflection, why electromagnetic fields extend beyond a boundary, and how their exponential decay explains applications such as fluorescence microscopy and optical coupling. An accessible physics extension guide with worked examples and challenging practice questions.
A beam of light travels through glass and strikes a glass-air boundary at an angle of 50° to the normal. The refractive indices are 1.50 for glass and 1.00 for air. Since the critical angle is approximately 41.8°, the ray diagram predicts total internal reflection. All the light is reflected, and no refracted ray enters the air.
Now place a fluorescent molecule just 100 nm above the glass surface. It can still be excited by the light.
How can something respond to light beyond the boundary if no light ray travels into that region?
The answer is an evanescent wave. It is an oscillating field that extends beyond the boundary but decreases exponentially with distance from it. It does not behave like an ordinary travelling ray.
This is extension material, beyond the required NSW Physics 11-12 (2025) syllabus. The Year 11 model of wavefronts, rays, refraction, and total internal reflection provides the prerequisite knowledge, rather than an assessment requirement for this particular topic. NESA schedules implementation of the 2025 syllabus for Year 11 from 2027, with the first HSC examination in 2028.
01Start with the Year 11 ray model
Before looking at what happens beyond the boundary, recall what you already know about wave behaviour.
A wavefront is a line joining points on a wave that are at the same phase of oscillation. A ray shows the direction in which the wave propagates and is perpendicular to its wavefronts.
When a wave encounters a boundary, its behaviour depends on the properties of the two media and the angle of incidence.
For light travelling from one medium into another, the relationship between the angles is described by Snell’s law:
\[ n_1\sin\theta_1=n_2\sin\theta_2 \]
Here:
- \(n_1\) is the refractive index of the original medium.
- \(n_2\) is the refractive index of the second medium.
- \(\theta_1\) is the angle of incidence, measured from the normal.
- \(\theta_2\) is the angle of refraction, also measured from the normal.
If light travels from a medium with a higher refractive index into one with a lower refractive index, it bends away from the normal.
As the angle of incidence increases, the refracted ray eventually reaches 90° to the normal. This is the critical angle, \(\theta_c\).
\[ \sin\theta_c=\frac{n_2}{n_1} \]
For angles greater than the critical angle, total internal reflection occurs.
The usual ray model then shows an incident ray and a reflected ray, with no refracted ray.
The ray diagram is correct. However, it does not show the complete electromagnetic field near the boundary.
That is the limitation we need to address.
02What actually exists beyond the boundary?
Imagine looking closely at the glass-air interface during total internal reflection.
The reflected beam travels back into the glass. However, the electromagnetic field does not suddenly become zero at the surface.
Instead, a small but non-zero field extends into the air.
This field is called an evanescent wave.
The important feature is that it behaves differently in two directions:
- Parallel to the boundary, the field has a travelling oscillatory pattern.
- Perpendicular to the boundary, its amplitude decreases exponentially.
Let the boundary lie horizontally. Define:
- \(x\) as the distance parallel to the boundary.
- \(z\) as the distance perpendicular to the boundary, measured into the air.
- \(t\) as time.
A simplified expression for one component of the electric field is:
\[ E(x,z,t)=E_0e^{-z/\delta_E} \cos(k_xx-\omega t+\phi) \]
The symbols describe the following:
| Symbol | Meaning |
|---|---|
| \(E\) | Electric field component |
| \(E_0\) | Field amplitude at the boundary |
| \(z\) | Perpendicular distance into the air |
| \(\delta_E\) | Electric-field amplitude decay length |
| \(k_x\) | Wave number parallel to the boundary |
| \(\omega\) | Angular frequency |
| \(\phi\) | Initial phase constant |
You do not need to solve this full expression. Focus on its two exponential and oscillatory parts.
The cosine term describes oscillation and phase progression along the boundary. The exponential term describes how quickly the field becomes weaker as you move into the air.
Think of the field as a thin, fading halo attached to the boundary. It has a recognisable oscillatory structure, but it becomes negligible quite quickly as you move away.
The analogy has a limit: the field is not a material substance sitting above the glass. It is an electromagnetic field, and its behaviour follows the wave equations and electromagnetic boundary conditions.
Amplitude and intensity are not the same thing
There is an important distinction here.
The electric field amplitude decreases exponentially according to:
\[ E(z)=E_0e^{-z/\delta_E} \]
However, electromagnetic intensity is proportional to the square of the electric field amplitude.
Therefore:
\[ I(z)=I_0e^{-2z/\delta_E} \]
Here, \(I_0\) is the intensity associated with the field at the boundary.
This means the intensity decreases faster than the field amplitude.
At a distance of one amplitude decay length, \(z=\delta_E\):
\[ \frac{E}{E_0}=e^{-1}\approx0.368 \]
But:
\[ \frac{I}{I_0}=e^{-2}\approx0.135 \]
So the field amplitude has fallen to approximately 37% of its boundary value, while the intensity has fallen to approximately 14%.
Be careful with the word penetration depth. Some optics references define it using the distance over which intensity falls to \(1/e\), rather than electric-field amplitude. Under our convention:
\[ \delta_I=\frac{\delta_E}{2} \]
Always check which quantity a problem or reference is describing.
If you need to revisit the distinction between amplitude and other wave measurements, see Wave Amplitude and Displacement Explained for HSC Physics.
03Why does an evanescent wave form?
The key is what happens to the wave when it reaches the boundary.
During ordinary refraction, the transmitted wave must satisfy Snell’s law. Its direction is determined by the refractive indices and the angle of incidence.
However, above the critical angle, Snell’s law would require:
\[ \sin\theta_2>1 \]
There is no real angle that satisfies this condition.
Does this mean the electromagnetic field in the second medium must be zero?
No. The electromagnetic fields must still satisfy the boundary conditions at the interface. They cannot simply disappear as soon as they cross the boundary.
Instead, the transmitted field takes an exponentially decaying form.
We can understand why without using advanced electromagnetic mathematics.
The wave-number explanation
A wave number describes how rapidly the phase of a wave changes with distance.
For light with vacuum wavelength \(\lambda_0\), the wave number in a medium of refractive index \(n\) is:
\[ k=\frac{2\pi n}{\lambda_0} \]
At the boundary, the phase pattern along the surface must match on both sides.
Therefore, the component of the wave number parallel to the boundary must remain the same.
For light travelling in medium 1:
\[ k_x=\frac{2\pi n_1}{\lambda_0}\sin\theta_i \]
Here, \(\theta_i\) is the angle of incidence.
In medium 2, the total wave number has magnitude:
\[ k_2=\frac{2\pi n_2}{\lambda_0} \]
For an ordinary travelling wave, its parallel and perpendicular components must satisfy:
\[ k_x^2+k_z^2=k_2^2 \]
But during total internal reflection:
\[ n_1\sin\theta_i>n_2 \]
This means:
\[ k_x>k_2 \]
Consequently, there is no real perpendicular wave-number component \(k_z\) that satisfies the equation.
The mathematical solution instead has an imaginary perpendicular component. When substituted into the wave expression, this produces an exponential decay rather than an ordinary travelling wave.
That is the origin of the evanescent field.
MIT OpenCourseWare develops this result in its Fundamentals of Photonics lecture notes.
Calculating the decay length
For total internal reflection at a flat interface between two transparent, non-magnetic materials, the electric-field amplitude decay length is:
\[ \boxed{ \delta_E= \frac{\lambda_0} {2\pi\sqrt{n_1^2\sin^2\theta_i-n_2^2}} } \]
The symbols are:
- \(\delta_E\): electric-field amplitude decay length, in metres.
- \(\lambda_0\): wavelength of light in a vacuum, in metres.
- \(n_1\): refractive index of the incident medium.
- \(n_2\): refractive index of the second medium.
- \(\theta_i\): angle of incidence, measured from the normal.
The equation assumes a monochromatic plane wave, a flat interface, homogeneous and lossless media, and total internal reflection.
It describes the spatial decay of the field. It does not, by itself, determine the complete reflected and transmitted power in a more complicated arrangement.
There are three useful predictions you can make from this equation.
1. Increasing the angle of incidence decreases the decay length.
As the angle moves further above the critical angle, the denominator increases. The field therefore decays more rapidly into the second medium.
2. Increasing the wavelength increases the decay length.
The decay length is directly proportional to the vacuum wavelength. Longer-wavelength light generally extends further into the second medium under otherwise identical conditions.
3. Increasing the refractive index of the second medium increases the decay length, provided total internal reflection still occurs.
This follows because \(n_2^2\) is subtracted inside the square root. As \(n_2\) approaches \(n_1\sin\theta_i\), the denominator becomes smaller.
At the critical angle, the denominator approaches zero and the decay length tends towards infinity. This is a limiting case: the refracted wave is grazing the boundary rather than being a confined evanescent field.
Worked example: Finding the decay length in glass
Light with a vacuum wavelength of 600 nm travels through glass with refractive index 1.50. It strikes an air boundary at an angle of 50° to the normal.
Calculate the critical angle and the electric-field amplitude decay length. Then determine the field amplitude at one decay length from the boundary.
Step 1
Use the critical-angle equation:
\[ \sin\theta_c=\frac{n_2}{n_1} \]
Substitute:
\[ \theta_c=\sin^{-1}\left(\frac{1.00}{1.50}\right) \]
\[ \theta_c=41.8^\circ \]
Since the incidence angle is 50°, which is greater than 41.8°, total internal reflection occurs.
Step 2
Use:
\[ \delta_E= \frac{\lambda_0} {2\pi\sqrt{n_1^2\sin^2\theta_i-n_2^2}} \]
Substitute:
\[ \delta_E= \frac{600} {2\pi\sqrt{1.50^2\sin^2 50^\circ-1.00^2}} \]
\[ \delta_E\approx168.7\text{ nm} \]
Therefore:
\[ \boxed{\delta_E\approx169\text{ nm}} \]
Step 3
At \(z=\delta_E\):
\[ \frac{E}{E_0}=e^{-\delta_E/\delta_E} \]
\[ \frac{E}{E_0}=e^{-1} \]
\[ \boxed{\frac{E}{E_0}\approx0.368} \]
The field amplitude is approximately 36.8% of its value at the boundary.
The corresponding intensity is only about 13.5% of its boundary value.
The important result is that the field is not restricted to the surface itself. It extends into the air over a characteristic distance of approximately 169 nm.
Worked example: Changing the angle of incidence
A beam of 600 nm light travels from glass (\(n_1=1.50\)) into air (\(n_2=1.00\)).
Compare its evanescent-field intensity at a distance of 100 nm from the boundary when the angle of incidence is 45° and 60°.
Assume the electric-field amplitude at the boundary, \(E_0\), is the same for both cases.
Step 1
\[ \delta_E= \frac{600} {2\pi\sqrt{1.50^2\sin^245^\circ-1.00^2}} \]
\[ \delta_E\approx270\text{ nm} \]
Step 2
\[ \delta_E= \frac{600} {2\pi\sqrt{1.50^2\sin^260^\circ-1.00^2}} \]
\[ \delta_E\approx115\text{ nm} \]
Notice that the larger incidence angle produces a much shorter decay length.
Step 3
Use:
\[ \frac{I}{I_0}=e^{-2z/\delta_E} \]
For 45°:
\[ \frac{I}{I_0}=e^{-2(100)/270} \]
\[ \boxed{\frac{I}{I_0}\approx0.48} \]
For 60°:
\[ \frac{I}{I_0}=e^{-2(100)/115} \]
\[ \boxed{\frac{I}{I_0}\approx0.18} \]
The field at 100 nm has considerably less intensity at the higher angle.
Both beams undergo total internal reflection, but their evanescent fields penetrate different distances into the air.
In an actual experiment, the boundary amplitude \(E_0\) can also change with angle and polarisation. Our assumption keeps that factor constant so we can isolate the effect of the decay length.
04Where are evanescent waves useful?
Evanescent waves are not just a mathematical curiosity. Their ability to concentrate an electromagnetic field near a boundary makes them useful in optical technologies.
Two applications are particularly interesting.
Total internal reflection fluorescence microscopy
Fluorescence microscopy allows scientists to observe fluorescent molecules by exciting them with light and detecting the light they subsequently emit.
A problem arises when the sample is thick.
If the entire sample is illuminated, molecules throughout its volume can fluoresce. This creates background light that makes it harder to distinguish structures close to the surface.
Total internal reflection fluorescence microscopy, usually called TIRF microscopy, addresses this problem.
A beam of light travels through a glass coverslip and strikes the glass-liquid boundary at an angle greater than the critical angle.
Total internal reflection occurs, producing an evanescent field in the liquid.
Fluorescent molecules close to the coverslip can interact with this field and become excited. Molecules further away experience a much weaker field and are less likely to fluoresce.
This allows researchers to investigate structures close to a surface while reducing background fluorescence from deeper parts of the sample.
The University of Melbourne describes this principle in its work on evanescent-wave-induced fluorescence spectroscopy.
Frustrated total internal reflection
Here is a more surprising application.
Imagine two glass prisms with a very thin air gap between them.
Light travels through the first prism and strikes its glass-air boundary above the critical angle. Under normal circumstances, it would undergo total internal reflection.
However, the second prism is positioned very close to the first.
The evanescent field extends through the air gap. If the gap is sufficiently small, the field can interact with the second glass surface.
This allows energy to transfer into the second prism, where a propagating light wave is produced.
The phenomenon is called frustrated total internal reflection.
Why does this happen if an isolated evanescent field does not carry energy away from the boundary in the perpendicular direction?
The crucial difference is the second boundary.
For an isolated, lossless glass-air interface, the time-averaged energy flow perpendicular to the interface is zero. The evanescent field can carry energy parallel to the boundary, but it does not transport a net amount into an infinitely extended air region.
When the second prism is introduced, the electromagnetic boundary conditions change. The field in the gap interacts with the second interface, allowing energy to transfer into the second prism.
A narrower gap generally produces stronger coupling. A much wider gap allows the field to decay before it reaches the second surface.
This is a classical wave phenomenon sometimes used as an optical analogy for quantum tunnelling. The analogy is useful, but the physical mechanisms are different.
Harvard University’s frustrated total internal reflection demonstration illustrates this effect using two glass prisms.
05Common misconceptions
| Tempting prediction | What actually happens |
|---|---|
| No refracted ray means there is no field in the second medium. | An evanescent field extends beyond the boundary. |
| An evanescent wave is just a weak travelling ray. | Its phase progresses parallel to the interface, while its amplitude decays perpendicular to it. |
| At one amplitude decay length, intensity is 37%. | Amplitude is approximately 37%; intensity is approximately 14%. |
| Total internal reflection means energy can never cross the boundary. | This is true for an isolated, ideal lossless interface, but not necessarily when an absorber or a second interface is introduced. |
| Increasing the angle of incidence increases penetration into the second medium. | Increasing the angle above the critical angle decreases the amplitude decay length. |
06Questions and solutions
The following questions move from standard calculations to more demanding applications. Use the amplitude decay-length equation and remember to distinguish field amplitude from intensity.
Question 1
Light travels through glass with refractive index \(n_1=1.52\) and strikes an air boundary with refractive index \(n_2=1.00\).
The vacuum wavelength is 520 nm, and the angle of incidence is 55°.
Calculate:
(a) The critical angle.
(b) The electric-field amplitude decay length.
(c) The electric-field amplitude as a fraction of its boundary value at a perpendicular distance equal to the decay length.
Solution 1
The critical angle is approximately 41.1°, the amplitude decay length is approximately 112 nm, and the field amplitude at one decay length is 36.8% of its boundary value.
Step 1: Calculate the critical angle.
\[ \theta_c=\sin^{-1}\left(\frac{n_2}{n_1}\right) \]
\[ \theta_c=\sin^{-1}\left(\frac{1.00}{1.52}\right) \]
\[ \boxed{\theta_c=41.1^\circ} \]
Since 55° is greater than 41.1°, total internal reflection occurs.
Step 2: Calculate the amplitude decay length.
\[ \delta_E= \frac{\lambda_0} {2\pi\sqrt{n_1^2\sin^2\theta_i-n_2^2}} \]
Substitute:
\[ \delta_E= \frac{520} {2\pi\sqrt{1.52^2\sin^255^\circ-1.00^2}} \]
\[ \boxed{\delta_E\approx112\text{ nm}} \]
Step 3: Calculate the remaining amplitude.
At one decay length:
\[ \frac{E}{E_0}=e^{-1} \]
\[ \boxed{\frac{E}{E_0}=0.368} \]
The electric-field amplitude has decreased to 36.8% of its value at the boundary.
The important point is that total internal reflection does not mean the field immediately disappears outside the glass.
Question 2
A 500 nm light beam travels from glass (\(n_1=1.50\)) into air (\(n_2=1.00\)).
Two separate beams strike the same type of boundary:
- Beam A has an incidence angle of 45°.
- Beam B has an incidence angle of 65°.
A detector is positioned 100 nm into the air.
Assume both beams have the same electric-field amplitude at the boundary.
(a) Calculate the amplitude decay length for each beam.
(b) Calculate the normalised intensity at the detector for each beam.
(c) Determine the ratio of the two detector intensities.
(d) Explain why the higher-angle beam produces a weaker field at the detector, even though both beams undergo total internal reflection.
Solution 2
Beam B produces approximately 24% of the normalised intensity of Beam A at the detector. Its higher incidence angle gives it a shorter evanescent decay length.
Step 1: Check the critical angle.
\[ \theta_c=\sin^{-1}\left(\frac{1.00}{1.50}\right) \]
\[ \theta_c=41.8^\circ \]
Both incidence angles exceed the critical angle, so both beams undergo total internal reflection.
Step 2: Calculate the decay length for Beam A.
\[ \delta_A= \frac{500} {2\pi\sqrt{1.50^2\sin^245^\circ-1.00^2}} \]
\[ \boxed{\delta_A\approx225\text{ nm}} \]
Step 3: Calculate the decay length for Beam B.
\[ \delta_B= \frac{500} {2\pi\sqrt{1.50^2\sin^265^\circ-1.00^2}} \]
\[ \boxed{\delta_B\approx86.4\text{ nm}} \]
Beam B has a much shorter decay length.
Step 4: Calculate the detector intensity for each beam.
Use:
\[ \frac{I}{I_0}=e^{-2z/\delta_E} \]
For Beam A:
\[ \frac{I_A}{I_0} =e^{-2(100)/225} \]
\[ \boxed{\frac{I_A}{I_0}\approx0.411} \]
For Beam B:
\[ \frac{I_B}{I_0} =e^{-2(100)/86.4} \]
\[ \boxed{\frac{I_B}{I_0}\approx0.099} \]
Step 5: Calculate the intensity ratio.
\[ \frac{I_B}{I_A} = \frac{0.099}{0.411} \]
\[ \boxed{\frac{I_B}{I_A}\approx0.24} \]
Beam B produces approximately 24% of Beam A’s normalised intensity at the detector.
The tempting prediction is that a higher incidence angle should allow the field to extend further along the surface and therefore increase its reach into the air.
However, the distance relevant to the exponential decay is perpendicular to the interface, not along a supposed refracted ray.
A larger incidence angle increases the decay constant, causing the field to decrease more rapidly with perpendicular distance.
Both beams are totally reflected, but their near-boundary field distributions are different.
Question 3
A fluorescence microscope uses a glass coverslip with refractive index 1.50 and a water-based sample with refractive index 1.33.
Light with a vacuum wavelength of 600 nm strikes the glass-water boundary at 70° to the normal.
Two groups of fluorescent molecules are positioned in the water:
- Group A is 50 nm from the glass surface.
- Group B is 500 nm from the glass surface.
Assume the molecules are sufficiently sparse that they do not significantly change the calculated decay length.
(a) Calculate the electric-field amplitude decay length.
(b) Calculate the normalised evanescent intensity at each group’s position.
(c) Explain why Group A can fluoresce even though total internal reflection occurs.
(d) Explain whether the reflected beam must remain completely unchanged when the fluorescent molecules absorb energy.
Solution 3
The amplitude decay length is approximately 205 nm. Group A experiences about 61% of the boundary intensity, while Group B experiences only about 0.75%. The near-surface molecules can therefore be excited much more effectively.
Step 1: Check for total internal reflection.
\[ \theta_c=\sin^{-1}\left(\frac{1.33}{1.50}\right) \]
\[ \theta_c\approx62.5^\circ \]
Since 70° is greater than 62.5°, total internal reflection occurs.
Step 2: Calculate the decay length.
\[ \delta_E= \frac{600} {2\pi\sqrt{1.50^2\sin^270^\circ-1.33^2}} \]
\[ \boxed{\delta_E\approx205\text{ nm}} \]
Step 3: Calculate the intensity at Group A.
For \(z=50\text{ nm}\):
\[ \frac{I_A}{I_0} =e^{-2(50)/205} \]
\[ \boxed{\frac{I_A}{I_0}\approx0.61} \]
Group A experiences approximately 61% of the boundary intensity.
Step 4: Calculate the intensity at Group B.
For \(z=500\text{ nm}\):
\[ \frac{I_B}{I_0} =e^{-2(500)/205} \]
\[ \boxed{\frac{I_B}{I_0}\approx0.0075} \]
Group B experiences less than 1% of the boundary intensity.
Step 5: Explain the fluorescence.
Group A can still absorb energy because the evanescent electric field is non-zero at its position.
The electric field interacts with the molecules, exciting them. They can then release energy as fluorescence.
Group B is much further from the interface, where the field has decayed substantially. Its excitation is therefore much weaker.
Step 6: Consider energy conservation.
There is an important qualification.
For an ideal, isolated, lossless glass-water boundary, the evanescent field has no net time-averaged energy flow perpendicular to the boundary.
However, introducing absorbing fluorescent molecules changes the physical system. The molecules provide an additional way for energy to be absorbed.
Consequently, the reflected beam can lose some energy to absorption and fluorescence. It need not remain perfectly unchanged.
This is not a contradiction. The zero-normal-energy-flow result applies to the ideal lossless interface, not necessarily to an interface containing absorbing material.
Question 4
A glass block has refractive index 1.50. Light with a vacuum wavelength of 600 nm strikes its surface at 65° to the normal.
The material on the other side of the boundary is changed between three different cases:
- Case A: air, with \(n_2=1.00\).
- Case B: a transparent liquid, with \(n_2=1.30\).
- Case C: a hypothetical transparent material, with \(n_2=1.40\).
Assume all materials are non-absorbing.
(a) Calculate the critical angle for Cases A and B.
(b) Calculate the amplitude decay length for Cases A and B.
(c) Determine whether total internal reflection occurs in Case C.
(d) Explain why increasing the refractive index of the second medium initially increases the evanescent decay length, rather than decreasing it.
Solution 4
Cases A and B both undergo total internal reflection. The decay length increases from approximately 104 nm in air to 240 nm in the liquid. Case C does not undergo total internal reflection at 65°, so the TIR evanescent-wave model no longer applies.
Step 1: Calculate the critical angle for Case A.
\[ \theta_{c,A} =\sin^{-1}\left(\frac{1.00}{1.50}\right) \]
\[ \boxed{\theta_{c,A}=41.8^\circ} \]
Since 65° exceeds the critical angle, total internal reflection occurs.
Step 2: Calculate the critical angle for Case B.
\[ \theta_{c,B} =\sin^{-1}\left(\frac{1.30}{1.50}\right) \]
\[ \boxed{\theta_{c,B}\approx60.1^\circ} \]
Again, 65° exceeds the critical angle, so total internal reflection occurs.
Step 3: Calculate the decay length in air.
\[ \delta_{E,A}= \frac{600} {2\pi\sqrt{1.50^2\sin^265^\circ-1.00^2}} \]
\[ \boxed{\delta_{E,A}\approx104\text{ nm}} \]
Step 4: Calculate the decay length in the liquid.
\[ \delta_{E,B}= \frac{600} {2\pi\sqrt{1.50^2\sin^265^\circ-1.30^2}} \]
\[ \boxed{\delta_{E,B}\approx240\text{ nm}} \]
The field extends further into the liquid than into the air.
Step 5: Consider Case C.
For \(n_2=1.40\):
\[ \theta_{c,C} =\sin^{-1}\left(\frac{1.40}{1.50}\right) \]
\[ \boxed{\theta_{c,C}\approx69.0^\circ} \]
The incidence angle is only 65°, which is now smaller than the critical angle.
Therefore, total internal reflection does not occur. A normal propagating refracted wave exists in the second medium.
The TIR evanescent decay-length equation is no longer applicable.
Step 6: Explain the change in decay length.
The tempting prediction is that increasing the refractive index of the second medium should make the field decay faster because light travels more slowly in that medium.
However, the decay length depends on the difference:
\[ n_1^2\sin^2\theta_i-n_2^2 \]
Increasing \(n_2\) makes this difference smaller, provided the TIR condition is still satisfied.
The denominator decreases, so the decay length increases.
Eventually, the critical angle becomes greater than the incidence angle. At that point, total internal reflection stops, and an ordinary refracted wave appears.
The key is that an evanescent wave exists only under the appropriate boundary conditions. You cannot keep applying its decay equation after those conditions have disappeared.
Question 5
Two identical glass prisms, each with refractive index 1.50, are positioned with a narrow air gap between their facing surfaces.
A 600 nm light beam travels through the first prism and strikes the glass-air interface at 50° to the normal.
The electric-field amplitude decay length for an isolated glass-air interface is approximately 169 nm.
The gap width is adjusted between two arrangements:
- Arrangement A: \(d=85\text{ nm}\).
- Arrangement B: \(d=338\text{ nm}\).
For an initial estimate, treat the first interface as isolated and use its exponential field profile to estimate the field at the far side of the air gap.
(a) Calculate the electric-field amplitude at the far side of each gap as a fraction of its value at the first boundary.
(b) Calculate the corresponding local intensity ratios.
(c) A student claims that these intensity ratios must be the percentages of incident light power transmitted into the second prism. Evaluate this claim.
(d) Another student argues that no energy can ever reach the second prism because total internal reflection has occurred at the first boundary. Explain why this is also incorrect.
(e) State what can be concluded about the effect of gap width and explain why the exact transmitted power cannot be calculated from the isolated-interface decay equation alone.
Solution 5
The narrower gap produces stronger evanescent coupling, but the calculated local intensity ratios are not the percentages of incident power transmitted through the second prism. The second boundary changes the electromagnetic field, allowing energy to cross the gap.
Step 1: Calculate the field amplitude ratio for Arrangement A.
The isolated-interface model gives:
\[ \frac{E(d)}{E_0}=e^{-d/\delta_E} \]
For \(d=85\text{ nm}\):
\[ \frac{E(d)}{E_0}=e^{-85/169} \]
\[ \boxed{\frac{E(d)}{E_0}\approx0.605} \]
The estimated field amplitude at the far side of the gap is approximately 60.5% of its value at the first boundary.
Step 2: Calculate the intensity ratio for Arrangement A.
\[ \frac{I(d)}{I_0} =e^{-2d/\delta_E} \]
\[ \frac{I(d)}{I_0}=e^{-170/169} \]
\[ \boxed{\frac{I(d)}{I_0}\approx0.366} \]
The local intensity estimate is approximately 36.6% of the boundary intensity.
Step 3: Calculate the field amplitude ratio for Arrangement B.
For \(d=338\text{ nm}\):
\[ \frac{E(d)}{E_0}=e^{-338/169} \]
\[ \boxed{\frac{E(d)}{E_0}\approx0.135} \]
The field amplitude is approximately 13.5% of its value at the first boundary.
Step 4: Calculate the intensity ratio for Arrangement B.
\[ \frac{I(d)}{I_0}=e^{-2(338)/169} \]
\[ \boxed{\frac{I(d)}{I_0}\approx0.0183} \]
The local intensity estimate is approximately 1.83% of its boundary value.
The comparison is:
| Quantity | Arrangement A | Arrangement B |
|---|---|---|
| Gap width | 85 nm | 338 nm |
| Field amplitude ratio | 0.605 | 0.135 |
| Intensity ratio | 0.366 | 0.0183 |
Step 5: Evaluate the claim about transmitted power.
The student’s claim is incorrect.
The calculated intensity ratios describe the field at the far side of the gap under the isolated-interface approximation.
They do not describe the fraction of incident power transmitted into the second prism.
There are two reasons.
First, the boundary intensity \(I_0\) is not necessarily equal to the incident beam intensity. The field amplitude at the boundary depends on the electromagnetic boundary conditions.
Second, the isolated-interface calculation assumes that the second prism does not affect the field. But the second prism is precisely what changes the situation.
The two interfaces must now be considered together.
Step 6: Explain how energy reaches the second prism.
For a single glass-air interface, the evanescent field has no net time-averaged energy flow perpendicular to the boundary.
However, the second prism is close enough to interact with that field.
The presence of the second interface changes the field distribution in the air gap. The resulting coupled electromagnetic field allows energy to transfer into the second prism, where a propagating wave can form.
This is frustrated total internal reflection.
The narrower gap in Arrangement A allows stronger coupling because the second interface is closer to the first. Arrangement B has a much weaker field at the far side of the gap in the isolated-interface estimate, so coupling is weaker.
Step 7: Explain why the exact transmitted power is unknown.
The isolated exponential equation describes the decay associated with one interface.
Once the second prism is introduced, the complete problem involves both interfaces, their electromagnetic boundary conditions, and the polarisation of the incident light.
The field in the gap is no longer simply the unmodified field of an isolated interface.
Therefore, the exponential estimates are useful for predicting the relative strength of coupling, but they cannot independently determine the exact transmitted power.
This is the important conceptual distinction: an evanescent field is not an ordinary beam travelling through the air gap, yet two nearby boundaries can interact through that field and transfer energy.
07What to understand next
Evanescent waves reveal a limitation of the simple ray model: knowing where a wave travels in a medium does not tell you everything about the field near its boundaries.
The next useful concept is optical waveguides.
In a fibre-optic cable, light is confined within a high-refractive-index core by repeated total internal reflection. However, the electromagnetic field also extends into the surrounding cladding as an evanescent field.
Understanding how that field behaves helps explain how optical fibres confine light, how nearby materials can interact with guided waves, and why the geometry of a waveguide determines which wave patterns it can support.