tutorgum
Try a Class

Buck Converters: Inductor Current and the Duty-Cycle Rule

Learn how buck converters use switching, inductors, and capacitors to produce a lower, smoother DC voltage. Explore the ideal duty-cycle relationship, current ripple, continuous and discontinuous conduction modes, and worked HSC-level extension problems.

A 24 V DC supply needs to power an electronic circuit designed to operate at 6 V. You could put a resistor in series to drop the extra voltage, but the resistor would waste energy as heat, and the output voltage would change as the load changed.

A buck converter takes a different approach. It switches the input supply on and off rapidly, then uses an inductor and a capacitor to produce a lower, much steadier DC voltage.

Here’s a prediction worth making before we start: if the switch is on for one-quarter of every switching cycle, would you expect the output voltage to be one-quarter of the input voltage?

For an ideal buck converter operating in continuous conduction mode, the answer is yes. Understanding why requires bringing together magnetic fields, electromagnetic induction, and energy conservation.

A 24 V DC battery connects to a central buck converter module containing a switching IC, inductor and capacitor. The converter supplies a lower 6 V DC output to an electronic sensor board. Positive input and output wires are distinguished by coral and green, with blue 0 V return wires.
The buck module switches the 24 V input and filters it into a steadier 6 V supply for the sensor board.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Where this sits in the HSC course: Buck converters are an extension beyond the required Year 12 Physics Electromagnetism content. They are not an additional HSC assessment requirement. Your Year 12 knowledge of electromagnetic induction and transformers is simply the starting point for this article.

The NSW Physics 11-12 Syllabus (2025) is scheduled for implementation from 2027, with its first HSC examination in 2028. The relevant background here is the study of Electromagnetism, rather than an expectation that students must learn buck converters for assessment. NESA syllabus information.

01A quick reminder: ideal and real transformers

Before looking at buck converters, let’s connect the idea to something you already know.

An ideal transformer transfers energy between two coils using a changing magnetic flux. An alternating current in the primary winding produces a changing magnetic field in the iron core, which induces an electromotive force (emf) in the secondary winding.

The ideal transformer model makes some important assumptions:

  • All the magnetic flux produced by the primary links the secondary.
  • The windings have zero electrical resistance.
  • No energy is dissipated through eddy currents in the core.
  • All the input power is transferred to the output.

Consequently, the ideal transformer obeys the power relationship:

\[ P_{\mathrm{in}}=P_{\mathrm{out}} \]

Using the simplified HSC transformer model:

\[ V_p I_p=V_s I_s \]

Here, \(V_p\) and \(I_p\) are the primary voltage and current, while \(V_s\) and \(I_s\) are the secondary voltage and current.

Real transformers do not satisfy these assumptions perfectly.

There are three important imperfections to understand.

1. Incomplete flux linkage

The ideal model assumes that the same magnetic flux links both windings.

In a real transformer, some magnetic field lines pass through the primary winding without passing through the secondary. This is called leakage flux.

As a result, the magnetic coupling between the windings is incomplete. The secondary does not receive exactly the induced emf predicted by the ideal model, and leakage inductance contributes to voltage drops when the transformer is supplying a load.

An important distinction: leakage flux is not itself a direct resistive heating loss. It affects how effectively the windings are coupled and how the secondary voltage behaves under load.

2. Eddy currents

The changing magnetic field also induces circulating currents within the conducting iron core.

These are called eddy currents.

Because the core has electrical resistance, these currents produce thermal energy through resistive heating. Energy that could otherwise contribute to useful output is dissipated as heat.

One way to reduce this effect is to construct the core from thin, electrically insulated sheets called laminations.

The insulation interrupts large circulating current paths, reducing the eddy currents and their associated heating.

3. Resistive heating in the windings

The copper or aluminium wire used in transformer windings has a small but non-zero resistance.

Whenever current flows through a resistance, electrical energy is dissipated as heat.

The power dissipated is:

\[ P_{\mathrm{loss}}=I^2R \]

Here, \(I\) is the current through the winding, measured in amperes, and \(R\) is its resistance, measured in ohms.

This means that winding losses increase with the square of the current. Doubling the current produces four times the resistive heating, assuming the resistance stays constant.

These imperfections explain why a real transformer delivers less useful power than an ideal one.

For a real transformer:

\[ P_{\mathrm{out}}<P_{\mathrm{in}} \]

Its efficiency is:

\[ \eta=\frac{P_{\mathrm{out}}}{P_{\mathrm{in}}} \]

The missing output power is associated with energy losses, particularly heating in the core and windings. Hysteresis is another real transformer loss, although our focus here is on the three mechanisms above.

If you want to explore the mathematical treatment of incomplete magnetic coupling, tutorgum’s article on Coupling Coefficients: Magnetic Flux Linkage in Real Transformers develops that foundation further.

Now we can move to a different way of controlling voltage.

02What is a buck converter?

A buck converter is an electronic circuit that converts a higher DC voltage into a lower DC voltage.

Unlike a conventional transformer, the basic buck converter does not transfer energy between two magnetically coupled windings. It is a non-isolated DC-to-DC converter, meaning its input and output share an electrical return path.

Instead, it uses four main components:

ComponentFunction
SwitchRapidly connects and disconnects the input supply.
DiodeProvides a path for current when the switch is off.
InductorStores energy in a magnetic field and smooths the current.
CapacitorSmooths the output voltage by absorbing and supplying current.

A load is connected across the output, receiving the reduced DC voltage.

The switch is commonly a MOSFET (metal-oxide-semiconductor field-effect transistor). In some modern designs, a second controlled transistor replaces the diode to improve efficiency.

The important component for understanding the operation is the inductor.

What happens when the switch turns on?

Imagine the switch closes.

The input supply is now connected to the inductor and output circuit. Current flows from the supply, through the switch and inductor, towards the load.

The voltage across the inductor is approximately:

\[ V_L=V_{\mathrm{in}}-V_{\mathrm{out}} \]

Because the input voltage is greater than the output voltage, the inductor experiences a positive voltage.

Its current begins increasing.

As current increases, a magnetic field develops around the inductor. Energy is stored in this magnetic field.

During this interval, the diode is reverse-biased, so it does not conduct.

What happens when the switch turns off?

Now the switch opens.

You might predict that the current immediately stops because the supply has been disconnected.

That prediction is incorrect.

An inductor opposes sudden changes in current. The magnetic field that developed during the on-state begins collapsing, releasing its stored energy.

The inductor maintains current through the load by using the diode as an alternative current path.

The current continues flowing through the inductor and load, even though the input switch is open.

During this interval, the voltage across the inductor is approximately:

\[ V_L=-V_{\mathrm{out}} \]

The negative voltage means that the inductor current decreases.

However, it does not necessarily fall to zero before the switch turns on again.

The important idea is that the inductor stores energy during one part of the cycle and releases it during another.

This allows the load to receive current throughout the switching cycle, even though the input switch repeatedly opens and closes.

Why does an inductor smooth current?

Think about a heavy flywheel.

If you give a flywheel a series of short pushes, it doesn’t immediately stop moving between pushes. Its stored rotational energy helps maintain its motion.

An inductor behaves in a similar way. Its magnetic field stores energy, allowing current to continue flowing between switching pulses.

The analogy isn’t exact: an inductor does not store mechanical motion, and its current is not perfectly constant. Instead, its rate of change depends on the voltage across it and its inductance.

The governing relationship is:

\[ V_L=L\frac{di_L}{dt} \]

Where:

  • \(V_L\) is the voltage across the inductor, in volts.
  • \(L\) is its inductance, measured in henries (H).
  • \(i_L\) is the current through the inductor, in amperes.
  • \(t\) is time, in seconds.

Rearranging gives:

\[ \frac{di_L}{dt}=\frac{V_L}{L} \]

This tells us something useful.

For a given voltage, a larger inductance produces a smaller rate of change in current.

The inductor therefore prevents the current from rapidly following the switching pulses.

Its current rises gradually while the switch is on and falls gradually while the switch is off.

It is not perfectly smooth. Instead, it has a small, repeated variation called current ripple.

The output capacitor helps smooth the voltage.

It is connected in parallel with the load. When the inductor supplies more current than the load requires, the excess current charges the capacitor.

When the inductor supplies less current than the load requires, the capacitor releases some of its stored charge to maintain the output.

In other words:

  • The inductor smooths the current.
  • The capacitor smooths the voltage.

Together, they turn a rapidly switched input into a much steadier DC output.

Continuous conduction mode

There is an important distinction between two ways a buck converter can operate.

In continuous conduction mode (CCM), the inductor current never reaches zero during a switching cycle.

It rises and falls, but always remains positive.

In discontinuous conduction mode (DCM), the inductor current reaches zero before the next switching cycle begins. It remains at zero for part of the cycle.

This distinction becomes important when we derive the output voltage relationship.

03The ideal duty-cycle relationship

Return to the original prediction.

Suppose we have an ideal buck converter supplied by 24 V. The switch is on for one-quarter of each switching cycle.

Would the output voltage be 6 V?

Under the ideal CCM model, yes.

The reason comes from the relationship between voltage and current in an inductor.

Understanding duty cycle

The duty cycle is the fraction of each switching period for which the switch is on.

It is represented by \(D\):

\[ D=\frac{t_{\mathrm{on}}}{T} \]

Where:

  • \(D\) is the duty cycle, a number between 0 and 1.
  • \(t_{\mathrm{on}}\) is the switch on-time.
  • \(T\) is the total switching period.

The switching period is related to switching frequency by:

\[ T=\frac{1}{f_s} \]

Here, \(f_s\) is the switching frequency, measured in hertz.

For example, a duty cycle of 0.25 means that the switch is on for 25% of each period and off for the remaining 75%.

Deriving the output voltage

We need one more idea: in steady-state operation, the inductor current must return to the same value at the end of every switching cycle.

Why?

If the current increased by a net amount during every cycle, it would keep increasing indefinitely. Similarly, if it decreased by a net amount every cycle, it would eventually reach zero.

Neither describes steady-state operation.

Therefore, the total change in inductor current over one complete switching period must be zero.

Because:

\[ V_L=L\frac{di_L}{dt} \]

this means that the positive and negative voltage contributions across the inductor must balance over one complete period.

This is called the volt-second balance principle.

Let’s examine the two switching intervals.

During the ON interval:

The inductor experiences a voltage of:

\[ V_L=V_{\mathrm{in}}-V_{\mathrm{out}} \]

This voltage acts for a fraction \(D\) of the switching period.

During the OFF interval:

The inductor experiences a voltage of:

\[ V_L=-V_{\mathrm{out}} \]

This voltage acts for the remaining fraction, \(1-D\).

The total volt-seconds must equal zero:

\[ (V_{\mathrm{in}}-V_{\mathrm{out}})DT - V_{\mathrm{out}}(1-D)T=0 \]

Cancel the common factor \(T\):

\[ (V_{\mathrm{in}}-V_{\mathrm{out}})D - V_{\mathrm{out}}(1-D)=0 \]

Expand:

\[ DV_{\mathrm{in}}-DV_{\mathrm{out}} - V_{\mathrm{out}}+DV_{\mathrm{out}}=0 \]

The two terms containing \(DV_{\mathrm{out}}\) cancel.

We are left with:

\[ DV_{\mathrm{in}}=V_{\mathrm{out}} \]

Therefore, the ideal buck converter relationship is:

\[ \boxed{V_{\mathrm{out}}=DV_{\mathrm{in}}} \]

This is the central equation for an ideal buck converter operating in continuous conduction mode.

The average output voltage is the input voltage multiplied by the duty cycle.

For example, if the input voltage is 24 V and the duty cycle is 0.25:

\[ V_{\mathrm{out}}=0.25\times24 \]

\[ V_{\mathrm{out}}=6.0\ \mathrm{V} \]

The converter produces an average output of 6 V.

When is this equation valid?

The relationship \(V_{\mathrm{out}}=DV_{\mathrm{in}}\) is powerful, but it is not universal.

It assumes:

  1. The converter is operating in continuous conduction mode.
  2. The circuit has reached steady-state operation.
  3. The switch, diode, and inductor are ideal, with no voltage drops or resistive losses.
  4. The output capacitor is sufficiently large that the output voltage changes very little during one switching period.

If these assumptions are not satisfied, the relationship may no longer predict the output correctly.

In particular, the duty-cycle relationship changes in discontinuous conduction mode. We will investigate that more carefully in the final question.

What about a real buck converter?

Real buck converters have losses too.

The MOSFET has a small resistance when conducting. The diode has a forward voltage drop. The inductor winding has resistance, and the switching device also loses energy during transitions between its on and off states.

Consequently:

\[ P_{\mathrm{out}}<P_{\mathrm{in}} \]

The efficiency is less than 100%.

A practical converter uses a control circuit to monitor the output voltage and adjust the duty cycle to maintain the required output.

The ideal relationship remains an excellent starting model, but the real circuit needs to compensate for component losses.

The switching operation and the different conduction modes are developed further in Stanford University’s EE152 power electronics notes.

04Worked examples

Worked example: calculating duty cycle and switching time

An ideal buck converter reduces a 24 V DC input to a 9.0 V output. It operates in continuous conduction mode at a switching frequency of 50 kHz.

Calculate:

(a) The duty cycle.

(b) The switch on-time.

Step 1

\[ V_{\mathrm{in}}=24\ \mathrm{V} \]

\[ V_{\mathrm{out}}=9.0\ \mathrm{V} \]

\[ f_s=50\,000\ \mathrm{Hz} \]

Step 2

Using the ideal buck converter relationship:

\[ V_{\mathrm{out}}=DV_{\mathrm{in}} \]

Rearrange:

\[ D=\frac{V_{\mathrm{out}}}{V_{\mathrm{in}}} \]

Substitute:

\[ D=\frac{9.0}{24} \]

\[ D=0.375 \]

The duty cycle is 0.375, or 37.5%.

Step 3

\[ T=\frac{1}{f_s} \]

\[ T=\frac{1}{50\,000} \]

\[ T=20\ \mu\mathrm{s} \]

Step 4

Rearrange the duty-cycle equation:

\[ t_{\mathrm{on}}=DT \]

\[ t_{\mathrm{on}}=0.375\times20 \]

\[ t_{\mathrm{on}}=7.5\ \mu\mathrm{s} \]

Final answer: The duty cycle is 37.5%, and the switch remains on for 7.5 microseconds during each 20-microsecond switching period.

This means the input supply is connected to the inductor for 37.5% of each cycle. The inductor and capacitor produce an average output voltage of 9.0 V.

Worked example: calculating inductor current ripple

An ideal buck converter reduces an 18 V DC supply to 6.0 V. It operates at 100 kHz and contains an inductor with an inductance of 150 μH.

The average load current is 0.80 A.

Calculate:

(a) The peak-to-peak inductor current ripple.

(b) The minimum and maximum inductor currents.

(c) Whether the converter operates in continuous conduction mode.

Step 1

\[ D=\frac{V_{\mathrm{out}}}{V_{\mathrm{in}}} \]

\[ D=\frac{6.0}{18} \]

\[ D=\frac{1}{3} \]

Step 2

\[ T=\frac{1}{100\,000} =10\ \mu\mathrm{s} \]

\[ t_{\mathrm{on}}=DT \]

\[ t_{\mathrm{on}}=\frac{1}{3}\times10 \]

\[ t_{\mathrm{on}}=3.33\ \mu\mathrm{s} \]

Step 3

Recall:

\[ V_L=L\frac{di_L}{dt} \]

For a constant voltage across the inductor:

\[ \Delta I_L=\frac{V_L\Delta t}{L} \]

During the ON interval:

\[ V_L=18-6=12\ \mathrm{V} \]

Substitute:

\[ \Delta I_{\mathrm{on}} = \frac{12\times3.33\times10^{-6}} {150\times10^{-6}} \]

\[ \Delta I_{\mathrm{on}}=0.267\ \mathrm{A} \]

The current increases by approximately 0.267 A.

Step 4

During the OFF interval:

\[ V_L=-6\ \mathrm{V} \]

The off-time is:

\[ t_{\mathrm{off}}=10-3.33 =6.67\ \mu\mathrm{s} \]

Therefore:

\[ \Delta I_{\mathrm{off}} = \frac{-6\times6.67\times10^{-6}} {150\times10^{-6}} \]

\[ \Delta I_{\mathrm{off}}=-0.267\ \mathrm{A} \]

The current decreases by approximately 0.267 A.

The increase and decrease are equal in magnitude, as expected in steady-state operation.

Therefore, the peak-to-peak current ripple is:

\[ \Delta I_{L,\mathrm{pp}}=0.267\ \mathrm{A} \]

Step 5

In continuous conduction mode, the average inductor current equals the average load current.

Therefore:

\[ I_{L,\mathrm{avg}}=0.80\ \mathrm{A} \]

The current varies equally above and below this average.

Minimum current:

\[ I_{\min}=I_{L,\mathrm{avg}} -\frac{\Delta I_{L,\mathrm{pp}}}{2} \]

\[ I_{\min}=0.80-\frac{0.267}{2} \]

\[ I_{\min}=0.667\ \mathrm{A} \]

Maximum current:

\[ I_{\max}=I_{L,\mathrm{avg}} +\frac{\Delta I_{L,\mathrm{pp}}}{2} \]

\[ I_{\max}=0.80+\frac{0.267}{2} \]

\[ I_{\max}=0.933\ \mathrm{A} \]

Step 6

The minimum inductor current is:

\[ I_{\min}=0.667\ \mathrm{A} \]

This is greater than zero.

Therefore, the current never stops flowing during the switching cycle.

The converter is operating in continuous conduction mode.

Final answer:

  • Peak-to-peak current ripple: 0.267 A.
  • Minimum inductor current: 0.667 A.
  • Maximum inductor current: 0.933 A.
  • Operating mode: continuous conduction mode.

Notice that the inductor current is not constant. It fluctuates around an average value, but the inductor prevents it from dropping to zero.

05Questions and solutions

Question 1

An ideal buck converter operates in continuous conduction mode with an input voltage of 20 V and a duty cycle of 0.30.

The average output current is 1.5 A.

Calculate:

(a) The average output voltage.

(b) The output power.

(c) The average input current, assuming the converter is ideal.

Solution 1

The output voltage is 6.0 V, the output power is 9.0 W, and the average input current is 0.45 A.

(a) Output voltage

Use the ideal buck converter relationship:

\[ V_{\mathrm{out}}=DV_{\mathrm{in}} \]

Substitute:

\[ V_{\mathrm{out}}=0.30\times20 \]

\[ V_{\mathrm{out}}=6.0\ \mathrm{V} \]

(b) Output power

Electrical power is:

\[ P_{\mathrm{out}}=V_{\mathrm{out}}I_{\mathrm{out}} \]

Substitute:

\[ P_{\mathrm{out}}=6.0\times1.5 \]

\[ P_{\mathrm{out}}=9.0\ \mathrm{W} \]

(c) Average input current

Because the converter is ideal, input power equals output power:

\[ P_{\mathrm{in}}=P_{\mathrm{out}} \]

Therefore:

\[ V_{\mathrm{in}}I_{\mathrm{in}} = V_{\mathrm{out}}I_{\mathrm{out}} \]

Rearrange:

\[ I_{\mathrm{in}} = \frac{P_{\mathrm{out}}}{V_{\mathrm{in}}} \]

Substitute:

\[ I_{\mathrm{in}}=\frac{9.0}{20} \]

\[ I_{\mathrm{in}}=0.45\ \mathrm{A} \]

The average input current is smaller than the output current.

This is not a violation of energy conservation. The converter reduces voltage while allowing a greater output current.

An ideal converter transfers the same power, not necessarily the same current.


Question 2

An ideal buck converter has an input voltage of 24 V and operates with a duty cycle of \(1/3\).

Its inductor has an inductance of 120 μH, and its switching frequency is 50 kHz.

Initially, the converter supplies an average load current of 0.60 A while operating in continuous conduction mode.

(a) Calculate the peak-to-peak inductor current ripple.

(b) Calculate the minimum inductor current.

(c) The load current is then reduced to 0.30 A, while the switching frequency and duty cycle remain unchanged. Explain what happens to the conduction mode.

(d) Calculate the average load current at the boundary between continuous and discontinuous conduction modes, using the original operating point.

Solution 2

The initial current ripple is 0.889 A, and the minimum inductor current is 0.156 A. When the load current falls to 0.30 A, the converter enters discontinuous conduction mode. The boundary current is approximately 0.444 A.

(a) Peak-to-peak current ripple

First, calculate the output voltage using the ideal CCM relationship:

\[ V_{\mathrm{out}}=DV_{\mathrm{in}} \]

\[ V_{\mathrm{out}}=\frac{1}{3}\times24 \]

\[ V_{\mathrm{out}}=8.0\ \mathrm{V} \]

Calculate the switching period:

\[ T=\frac{1}{50\,000} =20\ \mu\mathrm{s} \]

Calculate the on-time:

\[ t_{\mathrm{on}}=\frac{1}{3}\times20 \]

\[ t_{\mathrm{on}}=6.67\ \mu\mathrm{s} \]

During the ON interval:

\[ V_L=24-8=16\ \mathrm{V} \]

Using the inductor relationship:

\[ \Delta I_L=\frac{V_Lt_{\mathrm{on}}}{L} \]

\[ \Delta I_L= \frac{16\times6.67\times10^{-6}} {120\times10^{-6}} \]

\[ \Delta I_L=0.889\ \mathrm{A} \]

This is the peak-to-peak ripple.

(b) Minimum inductor current

The average inductor current equals the average load current:

\[ I_{L,\mathrm{avg}}=0.60\ \mathrm{A} \]

Therefore:

\[ I_{\min}=I_{L,\mathrm{avg}} -\frac{\Delta I_{L,\mathrm{pp}}}{2} \]

\[ I_{\min}=0.60-\frac{0.889}{2} \]

\[ I_{\min}=0.156\ \mathrm{A} \]

The current remains positive, so the original CCM assumption is valid.

(c) What happens when the load current falls to 0.30 A?

If we tried to maintain continuous conduction, the predicted minimum current would be:

\[ I_{\min}=0.30-\frac{0.889}{2} \]

\[ I_{\min}=-0.144\ \mathrm{A} \]

This is impossible for the assumed ideal diode-based converter.

The diode allows current to flow in one direction, but it prevents the inductor current from continuing into negative values.

Instead, the current falls to zero and stays there until the next switching cycle begins.

The converter enters discontinuous conduction mode.

The important point is that the original CCM output-voltage relationship can no longer be used to predict the output voltage at this lower load with the duty cycle fixed. The DCM behaviour must be analysed separately.

(d) Boundary current

At the boundary between CCM and DCM, the minimum current is exactly zero.

Therefore:

\[ 0=I_{\mathrm{boundary}} -\frac{\Delta I_{L,\mathrm{pp}}}{2} \]

Rearrange:

\[ I_{\mathrm{boundary}} =\frac{\Delta I_{L,\mathrm{pp}}}{2} \]

\[ I_{\mathrm{boundary}}=\frac{0.889}{2} \]

\[ I_{\mathrm{boundary}}=0.444\ \mathrm{A} \]

The boundary load current is approximately 0.444 A.

This means the converter operates in CCM above this boundary, under the original operating conditions, and enters DCM below it.


Question 3

A feedback-controlled ideal buck converter must maintain an output voltage of 5.0 V while supplying a constant load current of 1.0 A.

The input voltage can vary between 12 V and 20 V.

The converter has:

  • Inductance: 100 μH.
  • Switching frequency: 100 kHz.

Assume the converter remains in continuous conduction mode.

(a) Calculate the duty cycle when the input voltage is 12 V.

(b) Calculate the duty cycle when the input voltage increases to 20 V.

(c) Calculate the peak-to-peak inductor current ripple at both input voltages.

(d) Explain why the current ripple is larger at the higher input voltage, even though the switch is on for a shorter time.

Solution 3

The duty cycle decreases from 0.417 to 0.250 as the input voltage increases. However, the peak-to-peak current ripple increases from approximately 0.292 A to 0.375 A.

The key is that increasing the input voltage changes both the voltage across the inductor and the time for which that voltage acts.

(a) Duty cycle at 12 V

Use:

\[ D=\frac{V_{\mathrm{out}}}{V_{\mathrm{in}}} \]

\[ D=\frac{5.0}{12} \]

\[ D=0.417 \]

The switch is on for approximately 41.7% of each switching period.

(b) Duty cycle at 20 V

\[ D=\frac{5.0}{20} \]

\[ D=0.250 \]

The switch is now on for only 25% of each switching period.

This makes sense. A larger input voltage requires a smaller duty cycle to maintain the same average output voltage.

(c) Current ripple at both input voltages

First, calculate the switching period:

\[ T=\frac{1}{100\,000} =10\ \mu\mathrm{s} \]

For the 12 V input:

\[ t_{\mathrm{on}}=0.417\times10 \]

\[ t_{\mathrm{on}}=4.17\ \mu\mathrm{s} \]

The inductor voltage during the ON interval is:

\[ V_L=12-5=7\ \mathrm{V} \]

Therefore:

\[ \Delta I_L= \frac{7\times4.17\times10^{-6}} {100\times10^{-6}} \]

\[ \Delta I_L=0.292\ \mathrm{A} \]

For the 20 V input:

\[ t_{\mathrm{on}}=0.250\times10 \]

\[ t_{\mathrm{on}}=2.50\ \mu\mathrm{s} \]

The inductor voltage is now:

\[ V_L=20-5=15\ \mathrm{V} \]

Therefore:

\[ \Delta I_L= \frac{15\times2.50\times10^{-6}} {100\times10^{-6}} \]

\[ \Delta I_L=0.375\ \mathrm{A} \]

The results are:

Input voltageDuty cycleOn-timeCurrent ripple
12 V0.4174.17 μs0.292 A
20 V0.2502.50 μs0.375 A

(d) Explaining the larger ripple

The inductor current changes according to:

\[ \Delta I_L=\frac{V_L\Delta t}{L} \]

At 20 V, the voltage across the inductor during the ON interval is more than twice as large as it was at 12 V.

Although this voltage acts for a shorter time, the increase in the current’s rate of change is greater than the reduction in on-time.

Consequently, the current ripple increases.

We can also check that CCM remains valid in both cases.

At 12 V:

\[ I_{\min}=1.0-\frac{0.292}{2} \]

\[ I_{\min}=0.854\ \mathrm{A} \]

At 20 V:

\[ I_{\min}=1.0-\frac{0.375}{2} \]

\[ I_{\min}=0.813\ \mathrm{A} \]

Both minimum currents are positive.

The converter therefore remains in CCM in both situations.

The interesting result is that maintaining the same output voltage does not guarantee the same current ripple. The input voltage and switching conditions matter too.


Question 4

An ideal buck converter supplies an output voltage of 5.0 V and an inductor current of approximately 1.0 A.

Its output capacitor has a capacitance of 470 μF.

The load current suddenly decreases from 1.0 A to 0.40 A.

Assume that, during the first 100 μs after this change, the inductor current remains approximately constant at 1.0 A.

(a) Calculate the initial current flowing into or out of the capacitor.

(b) Calculate the approximate change in output voltage over the 100 μs interval.

(c) Explain why the output voltage changes even though the converter is designed to regulate it.

Solution 4

The capacitor initially receives 0.60 A, and the output voltage increases by approximately 0.128 V, reaching 5.13 V.

The important idea is that the inductor current cannot change instantaneously.

(a) Current flowing into the capacitor

At the output junction, the current supplied by the inductor must split between the load and capacitor.

Using Kirchhoff’s current law:

\[ I_L=I_{\mathrm{load}}+I_C \]

Rearrange:

\[ I_C=I_L-I_{\mathrm{load}} \]

Substitute:

\[ I_C=1.0-0.40 \]

\[ I_C=0.60\ \mathrm{A} \]

The capacitor receives 0.60 A.

It is therefore charging.

(b) Change in output voltage

The relationship between capacitor current and voltage is:

\[ I_C=C\frac{\Delta V}{\Delta t} \]

Rearrange:

\[ \Delta V=\frac{I_C\Delta t}{C} \]

Substitute the given values:

\[ \Delta V= \frac{0.60\times100\times10^{-6}} {470\times10^{-6}} \]

\[ \Delta V=0.128\ \mathrm{V} \]

The initial output voltage is 5.0 V.

Therefore:

\[ V_{\mathrm{final}}=5.0+0.128 \]

\[ V_{\mathrm{final}}\approx5.13\ \mathrm{V} \]

(c) Why does the output voltage rise?

The tempting prediction is that the output voltage should immediately remain at 5.0 V because the converter is designed to regulate it.

However, the inductor has stored energy in its magnetic field.

When the load current suddenly decreases, the inductor is still supplying approximately 1.0 A, even though the load only requires 0.40 A.

The excess current flows into the capacitor, increasing its stored charge and voltage.

The controller needs time to respond to the change. It can then reduce the duty cycle to decrease the energy supplied to the output.

This is an example of a transient response: the temporary behaviour of a system after its operating conditions change.

The calculation is approximate because we assumed constant capacitor current and constant inductor current over the stated interval. In an actual converter, the controller and changing inductor voltage affect the subsequent waveform.


Question 5

An ideal asynchronous buck converter has the following properties:

  • Input voltage: 24 V.
  • Duty cycle: 0.25.
  • Switching period: 10 μs.
  • Inductance: 22.5 μH.
  • Load resistance: 12 Ω.

The converter has an ideal diode that prevents the inductor current from flowing backwards.

Assume steady-state operation and an output capacitor sufficiently large that the output voltage remains approximately constant during each switching period.

Determine the actual average output voltage.

A student immediately applies:

\[ V_{\mathrm{out}}=DV_{\mathrm{in}} \]

and concludes that the output voltage must be 6 V.

Investigate whether this answer is physically consistent. If the converter operates in discontinuous conduction mode, determine the actual output voltage and verify your result by calculating how long the inductor current remains at zero.

Solution 5

The actual average output voltage is 8.0 V, not 6.0 V. The converter operates in discontinuous conduction mode, with the inductor current remaining at zero for 2.5 μs of each switching period.

This problem is harder because we cannot assume that the inductor current flows continuously.

We need to test the student’s CCM prediction before choosing the correct model.

Step 1: Test the continuous conduction assumption.

If the converter were operating in CCM, the output voltage would be:

\[ V_{\mathrm{out}}=DV_{\mathrm{in}} \]

\[ V_{\mathrm{out}}=0.25\times24 \]

\[ V_{\mathrm{out}}=6.0\ \mathrm{V} \]

The load current would then be:

\[ I_{\mathrm{out}}=\frac{V_{\mathrm{out}}}{R} \]

\[ I_{\mathrm{out}}=\frac{6.0}{12} \]

\[ I_{\mathrm{out}}=0.50\ \mathrm{A} \]

Now calculate the inductor current ripple.

The switch on-time is:

\[ t_{\mathrm{on}}=DT \]

\[ t_{\mathrm{on}}=0.25\times10 \]

\[ t_{\mathrm{on}}=2.5\ \mu\mathrm{s} \]

The inductor voltage during the ON interval would be:

\[ V_L=24-6=18\ \mathrm{V} \]

Therefore:

\[ \Delta I_L= \frac{18\times2.5\times10^{-6}} {22.5\times10^{-6}} \]

\[ \Delta I_L=2.0\ \mathrm{A} \]

If the average inductor current were 0.50 A, its minimum value would be:

\[ I_{\min}=0.50-\frac{2.0}{2} \]

\[ I_{\min}=-0.50\ \mathrm{A} \]

This is impossible under our assumed ideal diode model.

The diode prevents negative current, so the inductor current cannot follow this predicted triangular waveform.

Therefore, the CCM assumption is invalid.

We must investigate discontinuous conduction mode.

Step 2: Understand the three intervals in discontinuous conduction mode.

In DCM, each switching period contains three intervals:

  1. The switch is on, and the inductor current increases.
  2. The switch is off, and the inductor current decreases through the diode.
  3. The inductor current reaches zero and remains there until the next switching cycle.

This third interval is the crucial difference.

In CCM, the inductor current decreases throughout the entire OFF interval.

In DCM, it reaches zero before the next cycle begins.

Step 3: Calculate the peak inductor current.

Let the unknown output voltage be \(V\).

During the ON interval, the inductor experiences:

\[ V_L=V_{\mathrm{in}}-V \]

Using:

\[ V_L=L\frac{di_L}{dt} \]

the peak current is:

\[ I_{\mathrm{pk}} = \frac{(V_{\mathrm{in}}-V)t_{\mathrm{on}}}{L} \]

This assumes the current starts at zero, which is the defining starting condition for this DCM cycle.

Step 4: Calculate the time required for the current to return to zero.

During the diode-conduction interval, the inductor voltage is:

\[ V_L=-V \]

The current decreases at a rate determined by:

\[ \frac{di_L}{dt}=-\frac{V}{L} \]

The time required for the current to decrease from \(I_{\mathrm{pk}}\) to zero is:

\[ t_d=\frac{LI_{\mathrm{pk}}}{V} \]

Substitute the expression for peak current:

\[ t_d= \frac{L}{V} \left( \frac{(V_{\mathrm{in}}-V)t_{\mathrm{on}}}{L} \right) \]

Cancel \(L\):

\[ t_d= \frac{(V_{\mathrm{in}}-V)t_{\mathrm{on}}}{V} \]

The total time during which current flows is therefore:

\[ t_{\mathrm{on}}+t_d \]

Factor out \(t_{\mathrm{on}}\):

\[ t_{\mathrm{on}}+t_d = \frac{V_{\mathrm{in}}t_{\mathrm{on}}}{V} \]

Step 5: Relate average inductor current to load current.

The inductor current forms a triangular pulse during the two conduction intervals.

The average value over the complete switching period is the triangle’s area divided by the period.

Therefore:

\[ I_{L,\mathrm{avg}} = \frac{1}{2} \frac{I_{\mathrm{pk}}(t_{\mathrm{on}}+t_d)}{T} \]

In steady-state operation, the capacitor has no net change in stored charge over a complete cycle.

Consequently, the average inductor current equals the average load current:

\[ I_{L,\mathrm{avg}}=\frac{V}{R} \]

Combining these expressions:

\[ \frac{V}{R} = \frac{I_{\mathrm{pk}}(t_{\mathrm{on}}+t_d)} {2T} \]

Substitute the expressions from Steps 3 and 4:

\[ \frac{V}{R} = \frac{1}{2T} \left( \frac{(V_{\mathrm{in}}-V)t_{\mathrm{on}}}{L} \right) \left( \frac{V_{\mathrm{in}}t_{\mathrm{on}}}{V} \right) \]

Now use:

\[ t_{\mathrm{on}}=DT \]

After simplifying:

\[ V^2= \frac{RD^2TV_{\mathrm{in}}}{2L} (V_{\mathrm{in}}-V) \]

This is the relationship we need to determine the output voltage in this particular DCM situation.

Step 6: Substitute the known values.

\[ V^2= \frac{ 12(0.25)^2(10\times10^{-6})(24) }{ 2(22.5\times10^{-6}) } (24-V) \]

The coefficient simplifies to 4:

\[ V^2=4(24-V) \]

Expand:

\[ V^2=96-4V \]

Rearrange:

\[ V^2+4V-96=0 \]

Factorise:

\[ (V+12)(V-8)=0 \]

Therefore:

\[ V=-12\ \mathrm{V} \]

or

\[ V=8\ \mathrm{V} \]

The negative solution is not physically appropriate for the positive-output buck converter.

Hence:

\[ V_{\mathrm{out}}=8.0\ \mathrm{V} \]

Step 7: Verify that the converter really operates in DCM.

First, calculate the peak inductor current:

\[ I_{\mathrm{pk}} = \frac{(24-8)(2.5\times10^{-6})} {22.5\times10^{-6}} \]

\[ I_{\mathrm{pk}}=1.78\ \mathrm{A} \]

Now calculate the time required for this current to decrease to zero:

\[ t_d= \frac{(24-8)}{8}\times2.5 \]

\[ t_d=5.0\ \mu\mathrm{s} \]

The switch is on for 2.5 μs, and the diode conducts for another 5.0 μs.

The remaining time is:

\[ t_{\mathrm{zero}} = T-t_{\mathrm{on}}-t_d \]

\[ t_{\mathrm{zero}}=10-2.5-5.0 \]

\[ t_{\mathrm{zero}}=2.5\ \mu\mathrm{s} \]

The current therefore remains at zero for 2.5 μs.

We can check the average current too:

\[ I_{L,\mathrm{avg}} = \frac{1}{2} \times1.78 \times\frac{7.5}{10} \]

\[ I_{L,\mathrm{avg}}\approx0.667\ \mathrm{A} \]

The load current is:

\[ I_{\mathrm{out}}=\frac{8}{12} \]

\[ I_{\mathrm{out}}=0.667\ \mathrm{A} \]

The two values agree.

Our result is self-consistent.

Final answer: The actual output voltage is 8.0 V. The inductor current rises to approximately 1.78 A, falls to zero over 5.0 μs, and remains at zero for the remaining 2.5 μs of the switching period.

The student’s original answer of 6.0 V was tempting because it used the familiar ideal duty-cycle relationship. However, that relationship assumes continuous conduction. Once the inductor current reaches zero, the extra zero-current interval changes the voltage relationship.

This is the key lesson: the duty cycle alone does not always determine the output voltage. The conduction mode matters.


Once you can distinguish continuous from discontinuous conduction, you can start understanding how real buck converters maintain a stable output as the input voltage and load change.

The next useful concept is feedback control: how a controller measures the output voltage and continuously adjusts the duty cycle to compensate for changing operating conditions and real component losses.