tutorgum
Try a Class

Flyback Converters: How Magnetic Energy Is Stored and Released

Explore how flyback converters store energy in a magnetic field during the switch-on interval and transfer it to an output circuit when the switch turns off. Includes switching-cycle explanations, worked calculations, and challenging extension questions.

Switch off the primary transistor in a flyback converter and the output diode starts conducting. That sounds backwards. Why should opening a switch make energy flow to the output? The answer is that the converter has already stored energy in a magnetic field during the ON interval. The OFF interval releases that energy.

This is an extension beyond the required NSW HSC Physics syllabus. Year 12 Electromagnetism provides the foundation, but flyback converters are not an HSC assessment requirement.

01Start with the energy transformation

Before looking at the circuit, recall the difference between an electric motor and a generator.

Both use magnetic fields, but the direction of energy transfer is different.

DeviceEnergy inputEnergy outputMain electromagnetic process
Electric motorElectricalMechanicalForce on a current-carrying conductor in a magnetic field
Electric generatorMechanicalElectricalElectromagnetic induction from changing magnetic flux
Flyback converterElectricalElectricalTemporary storage and release of magnetic field energy

In a motor, electrical current flows through conductors in a magnetic field. The resulting magnetic force produces torque, causing the rotor to turn.

In a generator, mechanical motion changes the magnetic flux through a coil. An induced electromotive force (emf) drives an electrical current through an external circuit.

A flyback converter does neither of these things mechanically. There is no rotating shaft. Instead, it takes electrical energy, stores some of it temporarily in a magnetic field, and then delivers it to another electrical circuit.

Three physical illustrations compare a battery-powered cutaway electric motor driving a rotating shaft, a hand-cranked generator lighting a bulb, and an isolated flyback power supply with separate primary and secondary windings around a gapped ferrite core.
Motors convert electrical energy into motion; generators reverse that transfer, while flybacks store energy briefly in a magnetic field before delivering electrical output.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The connection to your HSC knowledge is electromagnetic induction.

Faraday’s law describes the induced emf:

\[ \mathcal{E}=-N\frac{\Delta\Phi}{\Delta t} \]

Here:

  • \(\mathcal{E}\) is the induced electromotive force, measured in volts.
  • \(N\) is the number of turns in the coil.
  • \(\Phi\) is the magnetic flux through each turn, measured in webers.
  • \(\Delta\Phi/\Delta t\) is the rate of change of magnetic flux.

The negative sign represents Lenz’s law: the induced effect opposes the change that produces it.

This becomes particularly important when we switch off the current in a flyback converter.

Imagine a current flowing through a coil. It produces a magnetic field. If we suddenly try to stop that current, the magnetic flux begins to decrease, producing an induced emf that opposes the decrease.

The coil therefore develops a voltage that tries to keep the current flowing.

Predict what happens when the primary switch opens: does the magnetic field instantly reverse direction?

No. The magnetic flux begins to decrease. Its rate of change reverses, causing the induced voltage polarity to reverse. The field itself does not instantly flip direction.

That change in voltage polarity is the key to the entire flyback mechanism.

02The magnetic component stores energy

A flyback converter uses two windings wrapped around a shared magnetic core. The component looks like a transformer, but its job is slightly different.

A conventional transformer is primarily designed to transfer electrical energy from its primary winding to its secondary winding. A flyback transformer is deliberately designed to store a useful amount of energy in its magnetic field before transferring that energy to the secondary.

In fact, it behaves more like a coupled inductor than an ordinary power transformer.

Think of compressing a spring.

You do work to compress it, storing energy. When you release the spring, that stored energy becomes available to do work elsewhere.

A flyback converter follows a similar sequence:

  • Switch ON: electrical energy builds the magnetic field.
  • Switch OFF: the magnetic field releases its stored energy into the output circuit.

The analogy is useful because it separates energy storage from energy release. However, there is no mechanical movement in the flyback converter. Its energy is stored in a magnetic field.

The air gap deserves attention.

In a typical flyback transformer, the magnetic core contains a small deliberate gap. The ferrite guides the magnetic flux, while much of the useful magnetic energy is stored in the field within this gap.

Why introduce a gap rather than use a completely closed magnetic core?

The gap increases the magnetic reluctance of the circuit. This reduces the effective inductance and allows the component to store useful energy without driving the ferrite core into saturation too quickly.

Magnetic saturation occurs when increasing the magnetising field produces relatively little additional magnetic flux. Once the core approaches saturation, its effective inductance can fall, causing current to rise much more rapidly.

The gap therefore plays an important role in the converter’s ability to store energy safely and predictably.

How much energy is stored?

For an ideal inductor with constant inductance, the magnetic energy stored is:

\[ U_B=\frac{1}{2}L_m I_m^2 \]

where:

  • \(U_B\) is the stored magnetic energy, measured in joules (J).
  • \(L_m\) is the primary-referred magnetising inductance, measured in henries (H).
  • \(I_m\) is the magnetising current, measured in amperes (A).

The equation gives us an important result.

The energy depends on the square of the current.

If the current doubles, the stored energy becomes four times as large, assuming the inductance remains constant.

This is why a relatively small increase in peak current can significantly increase the energy transferred during a switching cycle.

The equation assumes that the magnetic component is operating below saturation, so its inductance is approximately constant.

03A flyback converter’s switching cycle

A basic flyback converter contains five important elements:

  1. A DC input supply.
  2. A primary winding.
  3. A secondary winding.
  4. An electronic switch, usually a MOSFET (a transistor used as a fast switch).
  5. A secondary diode, output capacitor, and load.

The primary and secondary windings share magnetic flux, but they have no direct conducting connection between them. This provides galvanic isolation between the input and output circuits.

The diode controls the direction of energy transfer. Its orientation means that it blocks current during the primary switch-on interval and conducts during the switch-off interval.

Let’s follow one complete cycle.

Stage 1: The switch turns ON

When the MOSFET closes, the input supply is connected across the primary winding.

Current begins increasing through the primary winding. As this current increases, the magnetic flux in the core also increases.

The magnetic field stores energy.

At the same time, the changing flux induces a voltage in the secondary winding. However, because of the winding polarity and diode orientation, the secondary diode is reverse-biased.

It blocks current.

This means that during the ideal switch-on interval:

  • Primary current increases.
  • Magnetic field strength increases.
  • Magnetic energy is stored.
  • Secondary diode current is zero.
  • The output capacitor supplies the load.

Notice something important: the output is still receiving energy, even though the secondary diode is not conducting. The capacitor temporarily supplies the electrical energy required by the load.

The input supply is doing work during this interval, even though energy is not yet being delivered through the secondary winding.

Stage 2: The switch turns OFF

Now the MOSFET opens.

The primary current can no longer continue through the switch, but the magnetic field cannot disappear instantaneously.

The decreasing magnetic flux induces an emf in both windings.

Crucially, the polarity of the induced voltage reverses.

This reversal makes the secondary diode forward-biased. Current can now flow through the secondary winding, diode, and output circuit.

The stored magnetic energy is transferred to the output capacitor and load.

As this happens, the magnetic field weakens and the magnetising current decreases.

The process continues until the available magnetic energy has been transferred, or until the next switching event interrupts the process.

The primary and secondary currents are not the same electrons travelling between the windings. The windings remain electrically isolated. Energy is transferred through electromagnetic coupling.

Stage 3: The next switching cycle begins

The controller switches the MOSFET on again.

The primary current starts increasing, and the magnetic field begins storing energy again.

This process repeats many thousands of times per second in practical converters.

The output capacitor smooths the pulses of energy, allowing the load to receive a much steadier DC voltage.

Part of cyclePrimary magnetising currentSecondary diodeMain energy transfer
Switch ONIncreasingReverse-biasedInput supply to magnetic field
Switch OFFDecreasingForward-biasedMagnetic field to output
After energy release, if applicableZeroNot conductingOutput capacitor supplies load

The distinction between the two switching intervals is the central feature of flyback operation.

Stanford University’s EE152 course notes on flyback converters develop this idealised switching model. Texas Instruments also explains the energy-storage role of the gapped coupled inductor in its flyback converter application brief.

How does the converter control its output voltage?

The number of turns in each winding matters.

Let:

  • \(N_p\) be the number of turns in the primary winding.
  • \(N_s\) be the number of turns in the secondary winding.

For an ideal transformer, the magnitudes of the induced voltages are related by:

\[ \frac{|V_s|}{|V_p|} = \frac{N_s}{N_p} \]

Here, \(V_s\) is the secondary voltage and \(V_p\) is the primary voltage.

However, the turns ratio alone does not determine the flyback converter’s output voltage.

The timing of the switching cycle also matters.

A controller adjusts how long the MOSFET stays ON relative to the total switching period. This is called pulse-width modulation (PWM).

The fraction of each cycle spent with the switch ON is called the duty cycle:

\[ D=\frac{t_{\mathrm{on}}}{T} \]

Here:

  • \(D\) is the duty cycle.
  • \(t_{\mathrm{on}}\) is the switch-on time.
  • \(T\) is the total switching period.

Increasing the switch-on time generally allows more energy to be stored in the magnetic field, provided the converter has enough time to release that energy during the OFF interval.

By adjusting the switching timing, together with the winding turns ratio, a flyback converter can produce an output voltage higher or lower than its input voltage.

04Two different ways the magnetic energy can be released

There is one more distinction worth understanding.

The magnetising current does not always return to zero before the next switching cycle.

This creates two operating modes.

Discontinuous conduction mode (DCM)

In discontinuous conduction mode, the magnetising current starts at zero, increases during the ON interval, and returns to zero during the OFF interval.

There is then a period when no magnetising current flows before the next switching cycle.

The magnetic energy has been completely released in each cycle, assuming an ideal converter.

Consequently, the energy transferred per cycle is:

\[ \Delta U_B=\frac{1}{2}L_m I_{\mathrm{peak}}^2 \]

Here, \(I_{\mathrm{peak}}\) is the maximum magnetising current during the cycle.

Continuous conduction mode (CCM)

In continuous conduction mode, the magnetic energy is not completely released before the next switching cycle begins.

The magnetising current decreases during the OFF interval but remains above zero.

The next ON interval therefore starts with some current already flowing.

This changes how we calculate the energy transferred.

The energy stored at peak current is:

\[ U_{\mathrm{peak}} = \frac{1}{2}L_m I_{\max}^2 \]

However, some energy was already stored when the cycle began:

\[ U_{\mathrm{initial}} = \frac{1}{2}L_m I_{\min}^2 \]

Therefore, the energy transferred during the cycle is the difference:

\[ \boxed{ \Delta U_B= \frac{1}{2}L_m \left(I_{\max}^2-I_{\min}^2\right) } \]

Here, \(I_{\max}\) is the peak current and \(I_{\min}\) is the minimum current at the beginning and end of the cycle.

This is an important distinction.

A student might calculate the energy at peak current and assume that all of it is delivered to the output. That is only correct if the current returns to zero.

In CCM, some energy remains in the magnetic field.

Texas Instruments discusses these two operating modes and their current waveforms in its DCM flyback converter technical article.

A useful condition for continuous operation

In steady-state CCM, the magnetising current must return to the same value at the beginning of every switching cycle.

For an ideal converter, the voltage-time products across the magnetising inductance must balance:

\[ V_{\mathrm{in}}t_{\mathrm{on}} = V_Rt_{\mathrm{off}} \]

Here:

  • \(V_{\mathrm{in}}\) is the input voltage.
  • \(V_R\) is the magnitude of the output voltage reflected to the primary side.
  • \(t_{\mathrm{off}}\) is the time the primary switch remains open.

This is called volt-second balance.

If the positive voltage-time product is greater than the negative voltage-time product, the magnetising current increases from cycle to cycle.

If the negative product is greater, the current decreases.

This gives us a useful way to predict whether a converter can maintain a stable operating cycle.

One qualification: in DCM, there can be an additional zero-current interval. You must use the actual current-carrying OFF interval when applying the balance condition, rather than assuming the entire switch-off time is spent transferring energy.

05Worked examples

Worked example: Calculate the energy stored in a flyback transformer

An ideal flyback converter has a primary-referred magnetising inductance of \(0.80\ \mathrm{mH}\). At the end of the switch-on interval, the magnetising current is \(0.50\ \mathrm{A}\).

Calculate the magnetic energy stored in the component.

Step 1

\[ U_B=\frac{1}{2}L_m I_m^2 \]

Step 2

\[ L_m=0.80\times10^{-3}\ \mathrm{H} \]

Step 3

\[ U_B= \frac{1}{2} (0.80\times10^{-3}) (0.50)^2 \]

\[ U_B=1.0\times10^{-4}\ \mathrm{J} \]

Step 4

\[ \boxed{U_B=0.10\ \mathrm{mJ}} \]

The magnetic field stores \(0.10\ \mathrm{mJ}\) of energy.

If the converter operates in DCM and all stored energy is transferred ideally, this is the energy available to the output during that switching cycle.

If it operates in CCM, we would also need to know the minimum current to calculate the energy transferred.

Worked example: Calculate energy transfer and average output power in CCM

An ideal flyback converter operates in continuous conduction mode.

Its primary-referred magnetising inductance is \(0.60\ \mathrm{mH}\). The magnetising current falls from \(0.75\ \mathrm{A}\) to \(0.25\ \mathrm{A}\) during the energy-transfer interval.

The switching frequency is \(20\ \mathrm{kHz}\).

Calculate:

  1. The magnetic energy transferred during one cycle.
  2. The ideal average output power.

Step 1

The current does not return to zero. Therefore, some energy remains stored between cycles.

We must calculate the difference between the magnetic energy at maximum and minimum current.

\[ \Delta U_B= \frac{1}{2}L_m (I_{\max}^2-I_{\min}^2) \]

Step 2

\[ L_m=0.60\times10^{-3}\ \mathrm{H} \]

Step 3

\[ \Delta U_B= \frac{1}{2}(0.60\times10^{-3}) (0.75^2-0.25^2) \]

\[ \Delta U_B= 0.0003(0.5625-0.0625) \]

\[ \Delta U_B=1.5\times10^{-4}\ \mathrm{J} \]

Therefore:

\[ \boxed{\Delta U_B=150\ \mathrm{\mu J}} \]

Step 4

Power is energy transferred per unit time.

If the converter transfers \(150\ \mathrm{\mu J}\) per cycle and operates at \(20\,000\) cycles per second:

\[ P_{\mathrm{out}}=f_s\Delta U_B \]

\[ P_{\mathrm{out}} = 20\,000\times150\times10^{-6} \]

\[ \boxed{P_{\mathrm{out}}=3.0\ \mathrm{W}} \]

The ideal average output power is \(3.0\ \mathrm{W}\).

This calculation assumes that the converter returns to the same minimum current each cycle and that there are no energy losses.

The important point is that the output receives the difference between the maximum and minimum stored magnetic energy, not the entire energy present at peak current.

06Questions and solutions

Question 1

An ideal flyback converter has a primary-referred magnetising inductance of \(0.75\ \mathrm{mH}\).

It operates in discontinuous conduction mode. The magnetising current rises from zero to \(0.60\ \mathrm{A}\) during the switch-on interval, then returns completely to zero.

Calculate:

a) The maximum magnetic energy stored.

b) The ideal energy transferred to the output during one cycle.

Solution 1

The maximum stored energy is \(0.135\ \mathrm{mJ}\), and the ideal energy transferred per cycle is also \(0.135\ \mathrm{mJ}\).

Part a

Use the magnetic energy equation:

\[ U_B=\frac{1}{2}L_m I_{\mathrm{peak}}^2 \]

Convert the inductance:

\[ L_m=0.75\times10^{-3}\ \mathrm{H} \]

Substitute:

\[ U_B= \frac{1}{2}(0.75\times10^{-3})(0.60)^2 \]

\[ U_B=1.35\times10^{-4}\ \mathrm{J} \]

Therefore:

\[ \boxed{U_B=0.135\ \mathrm{mJ}} \]

Part b

The converter operates in DCM, so the magnetising current returns to zero before the next cycle.

This means all the magnetic energy stored during the ON interval is released during the OFF interval in the ideal model.

Therefore:

\[ \boxed{\Delta U_B=0.135\ \mathrm{mJ}} \]

The two answers are equal because no magnetic energy remains stored at the end of the cycle.

Question 2

An ideal flyback converter has:

  • Primary-referred magnetising inductance: \(0.40\ \mathrm{mH}\).
  • Input voltage: \(16\ \mathrm{V}\).
  • Initial magnetising current: \(0.20\ \mathrm{A}\).
  • Switch-on time: \(10\ \mathrm{\mu s}\).

Assume the input voltage and inductance remain constant during the ON interval.

Calculate:

a) The increase in magnetising current.

b) The current at the end of the ON interval.

c) The increase in magnetic energy during the ON interval.

Explain why the increase in energy is not equal to the total energy stored at the end.

Solution 2

The current increases by \(0.40\ \mathrm{A}\), reaching \(0.60\ \mathrm{A}\). The input adds \(64\ \mathrm{\mu J}\) of magnetic energy during the ON interval.

Part a

For an ideal inductor, the magnitude of the voltage across it is:

\[ V_{\mathrm{in}}= L_m\frac{\Delta I_m}{\Delta t} \]

Rearrange:

\[ \Delta I_m= \frac{V_{\mathrm{in}}t_{\mathrm{on}}}{L_m} \]

Substitute:

\[ \Delta I_m= \frac{16(10\times10^{-6})} {0.40\times10^{-3}} \]

\[ \boxed{\Delta I_m=0.40\ \mathrm{A}} \]

Part b

The initial current is already \(0.20\ \mathrm{A}\).

Therefore:

\[ I_{\mathrm{final}}=I_{\mathrm{initial}}+\Delta I_m \]

\[ I_{\mathrm{final}}=0.20+0.40 \]

\[ \boxed{I_{\mathrm{final}}=0.60\ \mathrm{A}} \]

Part c

We need to calculate the change in magnetic energy, not simply the energy at peak current.

\[ \Delta U_B= \frac{1}{2}L_m (I_{\mathrm{final}}^2-I_{\mathrm{initial}}^2) \]

Substitute:

\[ \Delta U_B= \frac{1}{2}(0.40\times10^{-3}) (0.60^2-0.20^2) \]

\[ \Delta U_B= 0.0002(0.36-0.04) \]

\[ \boxed{\Delta U_B=64\ \mathrm{\mu J}} \]

Why isn’t this the total stored energy?

Because the magnetic field already contained energy at the beginning of the interval.

Initially:

\[ U_{\mathrm{initial}} = \frac{1}{2}(0.0004)(0.20)^2 \]

\[ U_{\mathrm{initial}}=8\ \mathrm{\mu J} \]

At the end:

\[ U_{\mathrm{final}}= \frac{1}{2}(0.0004)(0.60)^2 \]

\[ U_{\mathrm{final}}=72\ \mathrm{\mu J} \]

The difference is:

\[ 72-8=64\ \mathrm{\mu J} \]

The input supplies the additional \(64\ \mathrm{\mu J}\). The original \(8\ \mathrm{\mu J}\) was already stored.

This is why you must distinguish total stored energy from the change in stored energy.

Question 3

Consider an ideal flyback converter with the following winding arrangement:

  • The primary winding has its polarity dot at the input-positive end.
  • The secondary winding has its polarity dot at the output-return end.
  • The secondary diode’s anode connects to the undotted secondary terminal.
  • The diode’s cathode connects to the positive terminal of the output capacitor.

The primary MOSFET is first switched ON and then switched OFF.

Explain:

a) Why the secondary diode is reverse-biased while the primary switch is ON.

b) Why the diode becomes forward-biased when the primary switch turns OFF.

c) How energy reaches the output load.

d) Why it is incorrect to say that electrons travel directly from the primary winding into the secondary winding.

Solution 3

The secondary diode is reverse-biased during the ON interval and forward-biased during the OFF interval. Energy crosses between the windings through magnetic coupling, not through electrons travelling directly between the two circuits.

Part a: Switch ON

Conventional current enters the dotted end of the primary winding.

Using the transformer dot convention, the dotted end of the secondary winding becomes positive relative to its undotted end while the magnetic flux is increasing.

However, the secondary dot is connected to the output return.

Therefore, the undotted secondary terminal becomes negative relative to the output return.

The diode’s anode is now at a lower potential than its cathode, which is connected to the positive output capacitor terminal.

The diode is reverse-biased, so it blocks secondary current.

Part b: Switch OFF

When the MOSFET opens, the primary magnetising current begins to decrease.

The decreasing magnetic flux induces an emf that opposes this change.

Consequently, the winding voltage polarities reverse.

The undotted secondary terminal becomes positive relative to the output return.

The diode’s anode is now at a higher potential than its cathode, so the diode becomes forward-biased.

Secondary current can flow.

Part c: Energy transfer

During the ON interval, the input supply builds the magnetic field and the output capacitor supplies the load.

During the OFF interval, the magnetic field releases its stored energy. The induced secondary current transfers energy to the output capacitor and load.

The capacitor smooths the pulsed energy delivery, helping maintain a relatively steady output voltage.

Part d: Electrical isolation

The primary and secondary windings are separate conductors.

Electrons in the primary winding do not travel through the magnetic core or insulation into the secondary winding.

Instead, a changing magnetic flux induces an emf in the secondary winding. This emf drives the electrons already present in the secondary circuit.

The energy is transferred magnetically, while the two circuits remain electrically isolated.

Question 4

An ideal flyback converter has the following properties:

  • Primary-referred magnetising inductance: \(0.50\ \mathrm{mH}\).
  • Input voltage: \(20\ \mathrm{V}\).
  • Reflected output voltage during the OFF interval: \(40\ \mathrm{V}\).
  • Switch-on time: \(10\ \mathrm{\mu s}\).

Assume the magnetising current is initially zero and the reflected output voltage remains constant.

Calculate:

a) The peak magnetising current.

b) The maximum magnetic energy stored.

c) The time required for the magnetising current to return to zero during the OFF interval.

d) Whether the converter operates in DCM at switching frequencies of \(20\ \mathrm{kHz}\), \(40\ \mathrm{kHz}\), and \(80\ \mathrm{kHz}\).

e) The residual magnetising current after the first OFF interval at \(80\ \mathrm{kHz}\).

Solution 4

The peak current is \(0.40\ \mathrm{A}\), and the magnetic field requires \(5\ \mathrm{\mu s}\) to discharge completely. The converter operates in DCM at \(20\) and \(40\ \mathrm{kHz}\), but not at \(80\ \mathrm{kHz}\).

Part a: Peak magnetising current

Use:

\[ \Delta I_m= \frac{V_{\mathrm{in}}t_{\mathrm{on}}}{L_m} \]

Substitute:

\[ \Delta I_m= \frac{20(10\times10^{-6})} {0.50\times10^{-3}} \]

\[ \boxed{I_{\mathrm{peak}}=0.40\ \mathrm{A}} \]

The current starts at zero, so the current increase equals the peak current.

Part b: Maximum magnetic energy

\[ U_B=\frac{1}{2}L_m I_{\mathrm{peak}}^2 \]

\[ U_B= \frac{1}{2}(0.50\times10^{-3})(0.40)^2 \]

\[ \boxed{U_B=40\ \mathrm{\mu J}} \]

Part c: Discharge time

During the OFF interval, the reflected output voltage acts across the magnetising inductance with a polarity that reduces current.

The magnitude of the current decrease per second is:

\[ \frac{\Delta I_m}{\Delta t} = \frac{V_R}{L_m} \]

Substitute:

\[ \frac{\Delta I_m}{\Delta t} = \frac{40}{0.50\times10^{-3}} \]

\[ =80\,000\ \mathrm{A\,s^{-1}} \]

The current starts at \(0.40\ \mathrm{A}\) and must decrease to zero.

Therefore:

\[ t_{\mathrm{discharge}} = \frac{0.40}{80\,000} \]

\[ \boxed{t_{\mathrm{discharge}}=5\ \mathrm{\mu s}} \]

The converter needs at least \(5\ \mathrm{\mu s}\) of active energy-transfer time to release all its stored magnetic energy.

Part d: Compare the switching frequencies

The switching period is:

\[ T=\frac{1}{f_s} \]

The OFF interval is:

\[ t_{\mathrm{off}}=T-t_{\mathrm{on}} \]

At \(20\ \mathrm{kHz}\):

\[ T=50\ \mathrm{\mu s} \]

\[ t_{\mathrm{off}}=50-10=40\ \mathrm{\mu s} \]

The OFF interval is much longer than the required \(5\ \mathrm{\mu s}\).

The converter operates in DCM.

At \(40\ \mathrm{kHz}\):

\[ T=25\ \mathrm{\mu s} \]

\[ t_{\mathrm{off}}=25-10=15\ \mathrm{\mu s} \]

Again, the current reaches zero before the next cycle.

The converter still operates in DCM.

At \(80\ \mathrm{kHz}\):

\[ T=12.5\ \mathrm{\mu s} \]

\[ t_{\mathrm{off}}=12.5-10 \]

\[ t_{\mathrm{off}}=2.5\ \mathrm{\mu s} \]

This is shorter than the required \(5\ \mathrm{\mu s}\).

The magnetising current cannot return to zero before the next cycle. The converter therefore enters continuous conduction rather than discontinuous conduction.

Part e: Residual current at 80 kHz

The current decreases at \(0.08\ \mathrm{A/\mu s}\).

During the \(2.5\ \mathrm{\mu s}\) OFF interval:

\[ \Delta I_m=0.08\times2.5 \]

\[ \Delta I_m=0.20\ \mathrm{A} \]

The current began at \(0.40\ \mathrm{A}\).

Therefore:

\[ I_{\mathrm{residual}}=0.40-0.20 \]

\[ \boxed{I_{\mathrm{residual}}=0.20\ \mathrm{A}} \]

The magnetic field still contains energy when the next cycle begins.

That remaining energy is:

\[ U_{\mathrm{remaining}} = \frac{1}{2}(0.50\times10^{-3})(0.20)^2 \]

\[ \boxed{U_{\mathrm{remaining}}=10\ \mathrm{\mu J}} \]

Only \(30\ \mathrm{\mu J}\) has been transferred during the first OFF interval.

Notice the consequence: increasing switching frequency does not always increase useful output power in direct proportion to frequency.

At \(40\ \mathrm{kHz}\), the energy per pulse is still \(40\ \mathrm{\mu J}\), so the ideal average output power is:

\[ P_{\mathrm{out}} = 40\times10^{-6}\times40\,000 \]

\[ \boxed{P_{\mathrm{out}}=1.6\ \mathrm{W}} \]

At \(80\ \mathrm{kHz}\), however, the current no longer resets. The energy transferred per cycle cannot simply be assumed to remain \(40\ \mathrm{\mu J}\).

If the same switching timing continues, the current valley rises from cycle to cycle. The converter is no longer operating in a stable periodic state under these assumptions.

Question 5

An ideal flyback converter is operating in continuous conduction mode.

At the beginning of a particular switching cycle, its magnetising current is \(0.90\ \mathrm{A}\).

The converter has the following properties:

QuantityValue
Input voltage, \(V_{\mathrm{in}}\)\(24\ \mathrm{V}\)
Magnetising inductance, \(L_m\)\(0.40\ \mathrm{mH}\)
Switch-on time, \(t_{\mathrm{on}}\)\(30\ \mathrm{\mu s}\)
Switch-off time, \(t_{\mathrm{off}}\)\(10\ \mathrm{\mu s}\)
Reflected output voltage, \(V_R\)\(36\ \mathrm{V}\)
Initial magnetising current\(0.90\ \mathrm{A}\)

Assume:

  • The reflected output voltage remains constant during the OFF interval.
  • The switch and diode are ideal.
  • The magnetising inductance remains constant during the calculations.
  • The output capacitor holds the output voltage approximately constant over the cycle.

A student claims:

“The maximum magnetic energy at the end of the ON interval is the energy delivered to the output during that cycle. The converter should therefore deliver all of that energy before the next cycle begins.”

Evaluate this claim.

Calculate:

a) The peak magnetising current.

b) The magnetising current at the end of the OFF interval.

c) The magnetic energy at the peak current.

d) The energy remaining in the magnetic field at the end of the OFF interval.

e) The energy transferred to the output during this cycle.

f) Whether repeating the same switching timing can produce a stable periodic current.

Finally, explain what physical limitation eventually becomes important if the current continues increasing.

Solution 5

The current rises from \(0.90\ \mathrm{A}\) to \(2.70\ \mathrm{A}\), then falls only to \(1.80\ \mathrm{A}\). The converter transfers \(0.810\ \mathrm{mJ}\) to the output but retains \(0.648\ \mathrm{mJ}\) in its magnetic field. Repeating the same switching timing causes the current to increase from cycle to cycle, so the converter cannot reach a periodic steady state.

Part a: Peak magnetising current

During the ON interval, the input voltage increases the magnetising current.

The current change is:

\[ \Delta I_m= \frac{V_{\mathrm{in}}t_{\mathrm{on}}}{L_m} \]

Substitute:

\[ \Delta I_m= \frac{24(30\times10^{-6})} {0.40\times10^{-3}} \]

\[ \Delta I_m=1.80\ \mathrm{A} \]

The initial current was \(0.90\ \mathrm{A}\).

Therefore:

\[ I_{\max}=0.90+1.80 \]

\[ \boxed{I_{\max}=2.70\ \mathrm{A}} \]

Part b: Current at the end of the OFF interval

During the OFF interval, the reflected output voltage reduces the magnetising current.

The magnitude of the current decrease is:

\[ \Delta I_m= \frac{V_Rt_{\mathrm{off}}}{L_m} \]

Substitute:

\[ \Delta I_m= \frac{36(10\times10^{-6})} {0.40\times10^{-3}} \]

\[ \Delta I_m=0.90\ \mathrm{A} \]

The current therefore finishes at:

\[ I_{\mathrm{final}}=2.70-0.90 \]

\[ \boxed{I_{\mathrm{final}}=1.80\ \mathrm{A}} \]

The magnetic current has decreased, but it has not returned to zero.

Part c: Magnetic energy at peak current

Use:

\[ U_{\mathrm{peak}} = \frac{1}{2}L_m I_{\max}^2 \]

Substitute:

\[ U_{\mathrm{peak}} = \frac{1}{2}(0.40\times10^{-3})(2.70)^2 \]

\[ U_{\mathrm{peak}} = 0.0002(7.29) \]

\[ \boxed{U_{\mathrm{peak}}=1.458\ \mathrm{mJ}} \]

Part d: Energy remaining after the OFF interval

The final current is \(1.80\ \mathrm{A}\), not zero.

Therefore, some magnetic energy remains stored.

\[ U_{\mathrm{remaining}} = \frac{1}{2}L_m I_{\mathrm{final}}^2 \]

Substitute:

\[ U_{\mathrm{remaining}} = \frac{1}{2}(0.40\times10^{-3})(1.80)^2 \]

\[ U_{\mathrm{remaining}} = 0.0002(3.24) \]

\[ \boxed{U_{\mathrm{remaining}}=0.648\ \mathrm{mJ}} \]

Part e: Energy transferred to the output

The student has confused the total magnetic energy at peak current with the energy released during the OFF interval.

The output receives only the difference between the peak magnetic energy and the remaining magnetic energy.

\[ \Delta U_B= U_{\mathrm{peak}}-U_{\mathrm{remaining}} \]

\[ \Delta U_B=1.458-0.648 \]

\[ \boxed{\Delta U_B=0.810\ \mathrm{mJ}} \]

The student’s claim is incorrect.

The converter does not release all \(1.458\ \mathrm{mJ}\). It releases \(0.810\ \mathrm{mJ}\), leaving \(0.648\ \mathrm{mJ}\) stored in the magnetic field.

This is consistent with energy conservation.

The input supplied energy during the ON interval. Some of that energy remains in the magnetic field after the OFF interval, while the rest is transferred to the output.

Part f: Can the same timing repeat in a stable cycle?

No. The magnetising current increases by \(0.90\ \mathrm{A}\) during every complete cycle.

We can verify this using volt-second balance.

During the ON interval, the voltage-time product is:

\[ V_{\mathrm{in}}t_{\mathrm{on}} = 24\times30 \]

\[ =720\ \mathrm{V\,\mu s} \]

During the OFF interval, the opposing voltage-time product is:

\[ V_Rt_{\mathrm{off}} = 36\times10 \]

\[ =360\ \mathrm{V\,\mu s} \]

The positive voltage-time product is larger.

The net voltage-time product is:

\[ 720-360=360\ \mathrm{V\,\mu s} \]

This produces a net current increase of:

\[ \Delta I_m= \frac{360\times10^{-6}} {0.40\times10^{-3}} \]

\[ \boxed{\Delta I_m=0.90\ \mathrm{A}} \]

The next cycle therefore begins at \(1.80\ \mathrm{A}\), rather than \(0.90\ \mathrm{A}\).

If the same timing repeats, the current continues increasing.

Eventually, our assumption of constant inductance becomes unrealistic.

As magnetising current increases, magnetic flux density also increases. The ferrite core approaches saturation.

Once saturation occurs, its effective inductance falls. For the same applied voltage, the current then increases more rapidly.

This can cause excessive current, heating, and component failure if the converter does not have appropriate control and protection.

A real flyback controller must therefore regulate the switching cycle and prevent the magnetising current from becoming excessive.

The important lesson is that increasing the ON interval does not guarantee that all the additional stored energy can be delivered to the output during the available OFF interval.

The timing of energy storage and energy release must work together.

07Where this leads next

A flyback converter is a useful application of electromagnetic induction because it makes the energy-storage stage visible. The input supplies energy, the magnetic field temporarily stores it, and the secondary winding delivers it when the switch opens.

The ideal model assumes perfect magnetic coupling between the windings. Real transformers are not perfect: some magnetic flux links one winding without linking the other.

This is called leakage flux, and the associated leakage inductance can produce unwanted voltage spikes when the switch turns OFF.

Understanding that limitation is the next step towards analysing real flyback converters. It connects directly to Coupling Coefficients: Magnetic Flux Linkage in Real Transformers.

The key distinction to carry forward is simple: a transformer can transfer energy between circuits, but a flyback converter deliberately stores magnetic energy first and releases it later. That difference determines how the entire switching cycle behaves.