Magnetohydrodynamic Generators: How Moving Fluids Generate Electricity

An accessible extension of Year 12 electromagnetism explaining how conducting fluids generate electricity when moving through a magnetic field. Explore induced voltage, electrical loading, magnetic braking, and energy transfer through worked examples and challenging questions.

Can a stream of hot gas generate electricity without spinning a turbine? Yes, provided the gas can conduct electricity. Move it through a magnetic field, collect the separated charges using electrodes, and connect an external circuit. The result is a magnetohydrodynamic generator.

This is an extension beyond the required HSC Physics syllabus, not an HSC assessment requirement. It builds on the Year 12 Electromagnetism model of the magnetic force experienced by a moving charged particle, then applies that model to an entire moving fluid.

Perspective cutaway of an insulated magnetohydrodynamic generator. Hot conducting gas flows rightward through a rectangular duct between N and S magnetic poles. Opposing side-wall electrodes connect to an external resistor. The conversion channel contains no rotating blades.
Hot conducting gas moves right through a downward magnetic field, separating charge at opposing electrodes and driving current through an external resistor.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

01Start with the force on one charged particle

Imagine a stream of electrically conducting gas travelling horizontally through a magnetic field.

Unlike ordinary air, an electrically conducting gas contains mobile charged particles. At sufficiently high temperatures, some gas atoms become ionised: electrons separate from atoms, leaving positively charged ions behind. The resulting mixture of electrons and ions is called a plasma.

Now consider what happens when this plasma enters a magnetic field.

Suppose:

  • The plasma travels to the right.
  • The magnetic field points into the page.
  • Both positive ions and electrons are carried along by the moving fluid.

Predict what happens to a positive ion and an electron. Are they pushed in the same direction?

They aren’t. The magnetic force acts in opposite directions on particles with opposite charges.

For a charged particle moving through a magnetic field, the magnetic force has magnitude

\[ F_B=|q|vB\sin\theta \]

where:

  • \(F_B\) is the magnetic force in newtons (N).
  • \(q\) is the particle’s electric charge in coulombs (C).
  • \(v\) is the particle’s speed in metres per second (m s\(^{-1}\)).
  • \(B\) is the magnetic flux density in tesla (T).
  • \(\theta\) is the angle between the particle’s velocity and the magnetic field.

When the particle moves perpendicular to the magnetic field,

\[ F_B=|q|vB \]

Using the right-hand rule for a positive charge, the force points upwards in our example. An electron experiences a force downwards.

This produces a separation of charge across the moving fluid.

There is an important detail here. The plasma remains almost electrically neutral overall. Only a very small separation of positive and negative charge is needed to establish an electric field.

The magnetic force on an individual particle is always perpendicular to its instantaneous velocity. It changes the particle’s direction rather than directly increasing its speed.

The useful feature for a generator is that the magnetic field pushes positive and negative charge carriers towards opposite sides of the moving fluid.

This is the same basic principle behind motional electromotive force in a moving metal conductor. The difference is that, in an MHD generator, the fluid itself acts as the conductor rather than a solid metal bar.

The analogy has limits: a metal bar has a fixed shape, whereas a fluid can deform, change speed, and vary in electrical conductivity as it flows.

02From charge separation to voltage

As positive ions accumulate on one side and electrons on the other, an electric field develops inside the fluid.

This electric field pushes positive charges in the opposite direction to the magnetic force.

Initially, charge separation increases. Eventually, if the electrodes are not connected to an external circuit, the electric force balances the magnetic force.

For perpendicular motion, the magnitudes of these forces balance when

\[ |q|E=|q|uB \]

where:

  • \(E\) is the magnitude of the electric field in volts per metre (V m\(^{-1}\)).
  • \(u\) is the bulk speed of the conducting fluid in metres per second.
  • \(B\) is the magnetic flux density in tesla.

Cancelling the charge gives

\[ E=uB \]

This is the electric field established across the fluid when the system reaches its open-circuit equilibrium.

If the electrodes are separated by a distance \(d\), the potential difference is

\[ V=Ed \]

Therefore, the open-circuit electromotive force is

\[ \boxed{\mathcal E_{\mathrm{oc}}=Bud} \]

Here, \(\mathcal E_{\mathrm{oc}}\) is the open-circuit emf, measured in volts, and \(d\) is the electrode separation in metres.

The equation assumes:

  • The fluid moves perpendicular to the magnetic field.
  • The electrode separation is aligned with the induced electric field.
  • The magnetic field and fluid velocity are approximately uniform.
  • Effects such as the Hall effect are negligible.

If the fluid velocity makes an angle \(\theta\) with the magnetic field, the corresponding idealised expression becomes

\[ \mathcal E_{\mathrm{oc}}=Bud\sin\theta \]

The voltage is greatest when the fluid moves perpendicular to the field. If the fluid moves parallel to the magnetic field, there is no motional emf in this arrangement.

Worked example: calculating the induced emf

A conducting fluid moves through a uniform magnetic field at 25 m s\(^{-1}\). The magnetic flux density is 0.80 T, and the electrodes are separated by 0.20 m. The fluid moves perpendicular to the magnetic field.

Calculate the open-circuit emf between the electrodes.

Step 1

The fluid moves perpendicular to the magnetic field, so

\[ \mathcal E_{\mathrm{oc}}=Bud \]

Step 2

\[ \begin{aligned} \mathcal E_{\mathrm{oc}} &=0.80\times25\times0.20\\ &=4.0\ \mathrm{V} \end{aligned} \]

Step 3

The open-circuit emf is 4.0 V.

This means a potential difference of 4.0 V develops between the electrodes. However, the circuit is open, so there is no sustained current and no electrical power is being delivered to an external load.

That last point becomes important when we connect the generator to a circuit.

03Connecting a load creates a braking force

So far, the fluid has developed a voltage, but we haven’t extracted electrical energy.

What changes if we connect the two electrodes to a resistor?

The separated charges can now move through an external circuit. A current flows through the conducting fluid, the electrodes, and the load.

The fluid is no longer simply developing an open-circuit voltage. It is now operating as a generator.

The conducting fluid has some electrical resistance. We can represent the simplest generator using an ideal emf source in series with an internal resistance \(r\).

The external resistor is the load, with resistance \(R\).

The current is then

\[ I=\frac{\mathcal E}{R+r} \]

where:

  • \(I\) is the conventional current in amperes (A).
  • \(\mathcal E\) is the generator’s emf in volts (V).
  • \(R\) is the external load resistance in ohms (\(\Omega\)).
  • \(r\) is the generator’s internal resistance in ohms (\(\Omega\)).

The voltage across the external load is

\[ V_L=IR \]

The electrical power delivered to that load is

\[ P_L=I^2R \]

Notice that the load voltage is generally smaller than the open-circuit emf.

Why?

Some of the voltage is lost across the generator’s internal resistance when current flows.

There are also two useful limiting cases.

Operating conditionCurrentLoad voltagePower delivered
Open circuit (\(R\rightarrow\infty\))ZeroMaximumZero
Short circuit (\(R=0\))MaximumZeroZero
Connected loadNon-zeroNon-zeroNon-zero

A generator needs both current and voltage to deliver power. A large voltage with zero current is not useful electrical output. Neither is a large current with zero load voltage.

But there’s something more interesting happening inside the fluid.

04Why the conducting fluid slows down

When current flows through a conductor in a magnetic field, the conductor experiences a magnetic force.

The same principle applies to the conducting fluid inside an MHD generator.

At the fluid level, the electromagnetic force per unit volume is described by

\[ \mathbf f=\mathbf J\times\mathbf B \]

where:

  • \(\mathbf f\) is the magnetic force per unit volume, in N m\(^{-3}\).
  • \(\mathbf J\) is the conventional current density, in A m\(^{-2}\).
  • \(\mathbf B\) is the magnetic flux density, in tesla.
  • The cross indicates a vector cross product.

In generator operation, this force acts against the direction of fluid flow.

This is the physical meaning of Lenz’s law in an MHD generator: the electromagnetic interaction opposes the motion responsible for generating the current.

Think about what this means.

Before the external circuit was connected, charge separation created a voltage without significant electromagnetic braking.

After the circuit was connected:

  • Current flowed through the conducting fluid.
  • The current interacted with the magnetic field.
  • A magnetic braking force acted on the fluid.
  • The fluid’s mechanical or thermal energy was transferred into electrical energy and heating.

The generator therefore extracts energy by resisting the fluid’s motion.

For a simplified uniform channel, the magnitude of the total force on the current-carrying fluid can be written as

\[ F=BId \]

Here, \(F\) is the total magnetic braking force in newtons, and \(d\) is the length of the current path through the fluid.

This is the same force relationship used for a current-carrying conductor in a magnetic field.

Where does the electrical energy actually come from?

This is a particularly important distinction.

The magnetic field is not an energy source.

The magnetic force on an individual charged particle is perpendicular to its instantaneous velocity, so that force does no work directly on the particle.

However, at the level of the entire conducting fluid, the electromagnetic interaction creates a braking force. The fluid loses mechanical energy, while the electrical circuit receives energy.

An external source must drive the fluid through the channel. Depending on the system, this energy comes from pressure differences, the fluid’s kinetic energy, and the thermal energy of a hot gas.

The magnetic field provides the coupling between the moving conductor and the electrical circuit. It does not provide the energy being extracted.

Worked example: calculating electrical output and magnetic braking

An MHD generator contains a conducting fluid moving at 40 m s\(^{-1}\) through a uniform magnetic field of 1.5 T.

The electrode separation is 0.30 m. The generator has an internal resistance of 1.0 \(\Omega\), and an external load of 2.0 \(\Omega\) is connected.

Assume uniform flow, a uniform magnetic field, and negligible additional losses.

Calculate:

  • The generator emf.
  • The current and load voltage.
  • The power delivered to the load.
  • The magnetic braking force and the mechanical power required to maintain the fluid’s speed.

Step 1

Using

\[ \mathcal E=Bud \]

\[ \begin{aligned} \mathcal E &=1.5\times40\times0.30\\ &=18\ \mathrm{V} \end{aligned} \]

The generator has an emf of 18 V.

Step 2

The internal and external resistances are in series.

\[ \begin{aligned} I&=\frac{\mathcal E}{R+r}\\ &=\frac{18}{2.0+1.0}\\ &=6.0\ \mathrm{A} \end{aligned} \]

The current is 6.0 A.

Step 3

The load voltage is

\[ \begin{aligned} V_L&=IR\\ &=6.0\times2.0\\ &=12\ \mathrm{V} \end{aligned} \]

The external load receives 12 V, rather than the full 18 V emf.

Step 4

\[ \begin{aligned} P_L&=I^2R\\ &=6.0^2\times2.0\\ &=72\ \mathrm{W} \end{aligned} \]

The load receives 72 W of electrical power.

The internal resistance also dissipates energy as heat:

\[ P_r=I^2r=6.0^2\times1.0 \]

\[ P_r=36\ \mathrm{W} \]

Therefore, the total electrical power generated is

\[ P_{\mathrm{total}}=72+36=108\ \mathrm{W} \]

Step 5

For the simplified channel,

\[ F=BId \]

Substituting,

\[ \begin{aligned} F&=1.5\times6.0\times0.30\\ &=2.7\ \mathrm{N} \end{aligned} \]

The fluid experiences a 2.7 N braking force.

Step 6

Mechanical power is force multiplied by velocity when the force and velocity are along the same line.

\[ \begin{aligned} P_{\mathrm{mech}}&=Fu\\ &=2.7\times40\\ &=108\ \mathrm{W} \end{aligned} \]

The external flow source must therefore supply 108 W to maintain the fluid’s speed against the electromagnetic braking force.

Notice the energy balance:

Energy transferPower
Mechanical power supplied to fluid108 W
Electrical power delivered to load72 W
Heating inside generator36 W
Total accounted for108 W

This is the central idea of MHD generation. Mechanical or thermal energy carried by the fluid is converted into electrical energy, with some energy also dissipated as heat.

05What does a real MHD generator look like?

The mathematical model is fairly simple. The actual engineering is not.

A typical high-temperature MHD power-generation concept works as follows.

1. Producing a conducting fluid

A fuel is burned to produce very hot gas. At sufficiently high temperatures, the gas becomes ionised and electrically conducting.

Some designs use additional easily ionised material to increase the number of mobile charge carriers and improve conductivity.

2. Accelerating the gas

The hot gas passes through a nozzle, which increases its velocity before it enters the MHD channel.

3. Extracting electrical energy

The gas flows through a strong magnetic field. Electrodes collect the separated charges and connect the conducting fluid to an external circuit.

The resulting current supplies electrical power to the load.

4. Recovering the remaining heat

The gas leaving the channel is still hot. It can pass through a heat-recovery system, which can produce steam to drive a conventional turbine.

This arrangement is interesting because the MHD channel can perform the functions of a turbine and generator in the same region, without requiring rotating turbine blades in the hottest part of the system.

MIT’s university-level treatment of MHD energy conversion describes this combination of fluid-flow and electrical-generation processes in detail.

Why aren’t MHD generators everywhere?

The underlying physics works, but several engineering problems make large-scale power generation difficult.

Electrical conductivity

Even very hot gases can have relatively low electrical conductivity. This limits the current that can be extracted and increases electrical losses.

High operating temperatures

The electrodes, duct walls, and surrounding equipment must survive extreme temperatures and demanding operating conditions.

Deposits and material problems

In coal-fired systems, combustion products can form deposits known as slag. These deposits interfere with the operation of the channel and its electrodes.

A 2004 review of open-cycle MHD power generation identifies low gas conductivity and slagging as major technical obstacles. These problems contributed to the failure of large-scale fossil-fuel MHD systems to become routine commercial power stations.

Where the simple equations stop being exact

The relationship

\[ \mathcal E_{\mathrm{oc}}=Bud \]

is an excellent starting model, but it is not a complete description of a real MHD generator.

It assumes a uniform magnetic field, a uniform fluid velocity, a simple electrode arrangement, and negligible Hall effects.

The Hall effect is an additional electrical effect that can cause current in an ionised gas to flow at an angle to the direction predicted by the simple model. This can require more complicated electrode arrangements.

There is another important limitation: the current changes the fluid’s motion.

If the load resistance changes, the current changes. That changes the magnetic braking force, which can change the fluid velocity. Since the induced emf depends on fluid velocity, the emf can change as well.

The fluid and electrical circuit therefore form a coupled system.

For the simplified equivalent circuit, with fluid speed held constant and internal resistance unchanged, maximum load power occurs when

\[ R=r \]

This is the maximum power transfer condition.

In a real MHD generator, however, changing the load also changes the fluid flow. The actual optimum operating condition can therefore differ from this simple prediction.

06Questions and solutions

The following questions build from calculating an induced voltage to analysing the interaction between electrical loading, fluid motion, and energy conservation.

Question 1

A conducting fluid travels at 15 m s\(^{-1}\) through a uniform magnetic field of 0.60 T. The fluid moves perpendicular to the field, and the electrodes are separated by 0.40 m in the direction of the induced electric field.

Calculate the open-circuit emf between the electrodes.

Solution 1

The open-circuit emf is 3.6 V.

The fluid moves perpendicular to the magnetic field, so the motional emf relationship applies:

\[ \mathcal E_{\mathrm{oc}}=Bud \]

Substituting,

\[ \begin{aligned} \mathcal E_{\mathrm{oc}} &=0.60\times15\times0.40\\ &=3.6\ \mathrm{V} \end{aligned} \]

The voltage between the electrodes is 3.6 V.

Because the circuit is open, no sustained current flows. The generator has established a potential difference, but it is not delivering electrical power to an external load.

Question 2

A rectangular MHD generator has the following properties:

  • Magnetic flux density: \(B=1.0\ \mathrm{T}\).
  • Fluid velocity: \(u=20\ \mathrm{m\,s^{-1}}\).
  • Electrode separation: \(d=0.20\ \mathrm{m}\).
  • Channel width: \(w=0.50\ \mathrm{m}\).
  • Active channel length: \(L=0.40\ \mathrm{m}\).
  • Fluid conductivity: \(\sigma=50\ \mathrm{S\,m^{-1}}\).
  • External load resistance: \(R=0.080\ \Omega\).

Assume the magnetic field and fluid velocity are uniform, and the current flows directly between the opposing electrodes.

The cross-sectional area perpendicular to the current is \(A=wL\). Ignore electrode contact resistance, Hall effects, and other additional losses.

Calculate:

(a) The internal resistance of the conducting fluid.

(b) The generator emf and current through the load.

(c) The voltage and power delivered to the external load.

(d) The magnetic braking force on the fluid.

(e) The mechanical power required to maintain the fluid’s speed, and explain how this compares with the electrical power generated.

Solution 2

The internal resistance is 0.020 Ω, the current is 40 A, and the external load receives 128 W. The fluid experiences an 8 N braking force, requiring 160 W of mechanical input power to maintain its speed.

Step 1: Calculate the conducting cross-sectional area.

The current flows across the electrode separation. Therefore, the area perpendicular to the current is

\[ \begin{aligned} A&=wL\\ &=0.50\times0.40\\ &=0.20\ \mathrm{m^2} \end{aligned} \]

Step 2: Calculate the internal resistance.

For a uniform conductor,

\[ r=\frac{d}{\sigma A} \]

Substituting,

\[ \begin{aligned} r&=\frac{0.20}{50\times0.20}\\ &=0.020\ \Omega \end{aligned} \]

Step 3: Calculate the generator emf.

\[ \begin{aligned} \mathcal E&=Bud\\ &=1.0\times20\times0.20\\ &=4.0\ \mathrm{V} \end{aligned} \]

Step 4: Calculate the current.

The internal and external resistances are in series.

\[ \begin{aligned} I&=\frac{\mathcal E}{R+r}\\ &=\frac{4.0}{0.080+0.020}\\ &=40\ \mathrm{A} \end{aligned} \]

Step 5: Calculate the load voltage and power.

\[ \begin{aligned} V_L&=IR\\ &=40\times0.080\\ &=3.2\ \mathrm{V} \end{aligned} \]

The power delivered to the load is

\[ \begin{aligned} P_L&=I^2R\\ &=40^2\times0.080\\ &=128\ \mathrm{W} \end{aligned} \]

Step 6: Calculate the magnetic braking force.

For the specified geometry,

\[ F=BId \]

\[ \begin{aligned} F&=1.0\times40\times0.20\\ &=8.0\ \mathrm{N} \end{aligned} \]

The electromagnetic force opposes the direction of fluid flow.

Step 7: Calculate the mechanical power.

The flow source must supply power against the braking force:

\[ \begin{aligned} P_{\mathrm{mech}}&=Fu\\ &=8.0\times20\\ &=160\ \mathrm{W} \end{aligned} \]

The internal resistance dissipates

\[ \begin{aligned} P_r&=I^2r\\ &=40^2\times0.020\\ &=32\ \mathrm{W} \end{aligned} \]

Therefore,

\[ P_{\mathrm{mech}}=P_L+P_r \]

\[ 160=128+32 \]

The energy balance is satisfied.

The important point is that the fluid’s mechanical energy supplies both the useful electrical output and the heating losses inside the generator.

Question 3

Consider an MHD generator with a passive external load connected.

Initially:

  • The conducting fluid moves to the right.
  • The magnetic field points into the page.
  • The electrodes are positioned above and below the fluid.

For each of the following arrangements, determine:

(a) Which electrode becomes positive.

(b) The direction of conventional current through the fluid.

(c) The direction of the magnetic braking force.

The three changes to consider are:

  • The magnetic field is reversed, but fluid flow remains unchanged.
  • Fluid flow is reversed, but the magnetic field remains unchanged.
  • Both fluid flow and the magnetic field are reversed.

A student claims that reversing the magnetic field must reverse the magnetic braking force, causing the fluid to accelerate.

Assess this claim.

Solution 3

Reversing just one of the two directions reverses the electrode polarity. Reversing both directions restores the original polarity. In every case, the magnetic braking force remains opposite to the actual fluid flow.

The key is to consider both the charge separation and the force on the current-carrying fluid.

Step 1: Analyse the original arrangement.

The fluid moves right and the magnetic field points into the page.

Using the right-hand rule, positive charges are pushed upwards.

Therefore:

  • Upper electrode: positive.
  • Lower electrode: negative.
  • Conventional current through the fluid: upwards.

The magnetic force on the fluid is

\[ \mathbf f=\mathbf J\times\mathbf B \]

With current upwards and magnetic field into the page, the force points left.

It opposes the rightward fluid flow.

Step 2: Reverse only the magnetic field.

The fluid still moves right, but the magnetic field now points out of the page.

The force on positive charges reverses, so they are pushed downwards.

Therefore:

  • Lower electrode: positive.
  • Upper electrode: negative.
  • Conventional current through the fluid: downwards.

The magnetic braking force still points left.

Why?

Both the current direction and magnetic field direction have reversed relative to the original arrangement. Reversing both vectors in a cross product leaves the direction of their product unchanged.

Step 3: Reverse only the fluid flow.

The fluid now moves left, while the magnetic field still points into the page.

Positive charges are pushed downwards.

Therefore:

  • Lower electrode: positive.
  • Upper electrode: negative.
  • Conventional current through the fluid: downwards.

The magnetic braking force points right, opposing the leftward fluid flow.

Step 4: Reverse both the fluid flow and magnetic field.

The fluid moves left and the magnetic field points out of the page.

The positive charges are pushed upwards.

Therefore:

  • Upper electrode: positive.
  • Lower electrode: negative.
  • Conventional current through the fluid: upwards.

The magnetic braking force points right, again opposing the fluid flow.

The results can be summarised:

Fluid flowMagnetic fieldPositive electrodeCurrent through fluidBraking force
RightInto pageUpperUpLeft
RightOut of pageLowerDownLeft
LeftInto pageLowerDownRight
LeftOut of pageUpperUpRight

The student’s mistake is considering the magnetic field reversal without considering the simultaneous reversal of the induced current.

The force depends on both:

\[ \mathbf f=\mathbf J\times\mathbf B \]

In generator operation, the current changes direction in response to the changed magnetic field or flow direction. The resulting electromagnetic force continues to oppose the flow.

This is exactly what we expect from Lenz’s law.

Question 4

An MHD generator is modelled as an ideal emf source in series with an unknown internal resistance \(r\).

A variable external load is connected, and the following measurements are recorded.

Load resistance \(R\) (\(\Omega\))Current \(I\) (A)Terminal voltage \(V_L\) (V)
144
236
428
10110

(a) Determine the generator’s emf and internal resistance.

(b) Calculate the power delivered to the load for each measurement.

(c) Identify the load resistance that produces maximum electrical power.

(d) Explain why the setting with the highest terminal voltage does not produce the highest power.

Solution 4

The generator has an emf of 12 V and an internal resistance of 2 Ω. The maximum power in the measured data is 18 W, obtained with a 2 Ω load.

Step 1: Establish the relationship between emf and terminal voltage.

The terminal voltage is the emf minus the voltage drop across the internal resistance:

\[ V_L=\mathcal E-Ir \]

Rearranging,

\[ \mathcal E=V_L+Ir \]

Step 2: Use two measurements to determine the unknowns.

Using the first measurement,

\[ \mathcal E=4+4r \]

Using the second measurement,

\[ \mathcal E=6+3r \]

Since both expressions represent the same emf,

\[ 4+4r=6+3r \]

Therefore,

\[ r=2\ \Omega \]

Substituting into either measurement,

\[ \begin{aligned} \mathcal E&=4+4(2)\\ &=12\ \mathrm{V} \end{aligned} \]

The generator’s emf is 12 V, and its internal resistance is 2 Ω.

Step 3: Calculate the power delivered for each load.

Use

\[ P_L=V_LI \]

Load resistanceCurrentVoltageLoad power
1 Ω4 A4 V16 W
2 Ω3 A6 V18 W
4 Ω2 A8 V16 W
10 Ω1 A10 V10 W

Step 4: Identify the maximum power condition.

The maximum measured power is 18 W, occurring when

\[ R=2\ \Omega \]

This equals the internal resistance of the generator.

For the ideal equivalent circuit, the load power is

\[ P_L=\frac{\mathcal E^2R}{(R+r)^2} \]

This expression reaches its maximum when the load resistance equals the internal resistance.

Step 5: Explain why the highest voltage does not mean the highest power.

The 10 Ω load receives the highest terminal voltage, 10 V. However, its current is only 1 A.

Its power is therefore

\[ P_L=10\times1=10\ \mathrm{W} \]

The 2 Ω load receives only 6 V, but its current is 3 A.

Its power is

\[ P_L=6\times3=18\ \mathrm{W} \]

The highest voltage and highest power are not necessarily obtained at the same operating condition.

This is a useful design principle: the generator must be matched to its electrical load.

There is one further limitation. The maximum power condition \(R=r\) assumes that the emf and internal resistance remain constant. In a real MHD generator, changing the load can also change the fluid velocity through magnetic braking, so the actual optimum can shift.

Question 5

A conducting fluid packet of mass 1.0 kg enters an idealised MHD generator at 20 m s\(^{-1}\) and leaves at 12 m s\(^{-1}\).

The generator is connected to an external load of resistance 3.0 Ω. Its internal resistance is 1.0 Ω.

At the entry speed, the generator’s open-circuit motional emf would be 10 V.

Assume:

  • The magnetic field and electrode separation remain constant throughout the channel.
  • The emf is proportional to the instantaneous fluid speed.
  • The internal and external resistances remain constant.
  • No pressure work or heat enters the fluid packet while it is inside the generator.
  • The only reduction in the packet’s translational kinetic energy is due to electromagnetic energy extraction.
  • All energy removed from the packet is accounted for by electrical energy generated, including internal resistive heating.

Answer the following.

(a) Calculate the reduction in the fluid packet’s kinetic energy.

(b) Calculate the total energy delivered to the external load and the energy dissipated inside the generator.

(c) Calculate the current and terminal voltage at the entry and exit speeds.

(d) A student argues that because the magnetic field, electrode separation, and resistance remain constant, the generator current must also remain constant. Explain the error.

(e) Suppose the magnetic field is doubled, but the same entry and exit speeds are retained. Would the total energy delivered to the external load increase? Explain what must change in the physical operation of the generator.

Solution 5

The fluid loses 128 J of kinetic energy. Of this, 96 J reaches the external load, while 32 J is dissipated as internal heating.

The current falls from 2.5 A to 1.5 A as the fluid slows down. The key is that the induced emf depends on the instantaneous fluid velocity, not just the magnetic field and electrode separation.

Step 1: Calculate the reduction in kinetic energy.

The initial kinetic energy is

\[ \begin{aligned} E_{k,i} &=\frac12mu_i^2\\ &=\frac12\times1.0\times20^2\\ &=200\ \mathrm{J} \end{aligned} \]

The final kinetic energy is

\[ \begin{aligned} E_{k,f} &=\frac12mu_f^2\\ &=\frac12\times1.0\times12^2\\ &=72\ \mathrm{J} \end{aligned} \]

Therefore, the reduction in kinetic energy is

\[ \begin{aligned} \Delta E_k &=200-72\\ &=128\ \mathrm{J} \end{aligned} \]

Under the assumptions in the question, 128 J is the total electrical energy generated.

Step 2: Determine how much energy reaches the load.

The load resistance is 3.0 Ω, and the internal resistance is 1.0 Ω.

The fraction of generated electrical energy delivered to the load is

\[ \frac{R}{R+r} \]

Therefore,

\[ \begin{aligned} E_L &=128\times\frac{3.0}{3.0+1.0}\\ &=128\times0.75\\ &=96\ \mathrm{J} \end{aligned} \]

The external load receives 96 J.

The remaining energy is dissipated internally:

\[ \begin{aligned} E_r&=128-96\\ &=32\ \mathrm{J} \end{aligned} \]

The energy balance is satisfied:

\[ 128=96+32 \]

Step 3: Calculate the entry current and terminal voltage.

At the entry speed, the emf is 10 V.

The total circuit resistance is

\[ R_{\mathrm{total}}=3.0+1.0=4.0\ \Omega \]

Therefore,

\[ \begin{aligned} I_i&=\frac{10}{4.0}\\ &=2.5\ \mathrm{A} \end{aligned} \]

The entry terminal voltage is

\[ \begin{aligned} V_{L,i}&=I_iR\\ &=2.5\times3.0\\ &=7.5\ \mathrm{V} \end{aligned} \]

Step 4: Calculate the exit current and terminal voltage.

The magnetic field and electrode separation remain unchanged.

However, the fluid speed has fallen from 20 m s\(^{-1}\) to 12 m s\(^{-1}\).

Since

\[ \mathcal E=Bud \]

the emf scales directly with fluid velocity.

Therefore,

\[ \begin{aligned} \mathcal E_f &=10\times\frac{12}{20}\\ &=6.0\ \mathrm{V} \end{aligned} \]

The exit current is

\[ \begin{aligned} I_f&=\frac{6.0}{4.0}\\ &=1.5\ \mathrm{A} \end{aligned} \]

The exit terminal voltage is

\[ \begin{aligned} V_{L,f}&=1.5\times3.0\\ &=4.5\ \mathrm{V} \end{aligned} \]

The results are:

QuantityEntryExit
Fluid speed20 m s\(^{-1}\)12 m s\(^{-1}\)
Generator emf10 V6 V
Current2.5 A1.5 A
Terminal voltage7.5 V4.5 V

Step 5: Explain the error in the student’s argument.

The student has assumed that the generator emf depends only on the magnetic field and electrode separation.

But the equation is

\[ \mathcal E=Bud \]

All three quantities matter.

Even though \(B\) and \(d\) remain constant, the fluid speed \(u\) decreases because the generator extracts energy from the moving fluid.

Consequently, the induced emf decreases, and so do the current and terminal voltage.

This is an important feedback mechanism: electrical energy extraction changes the motion that produces the emf in the first place.

Step 6: Analyse what happens if the magnetic field doubles.

The total energy delivered to the load does not automatically increase.

The packet still loses the same amount of kinetic energy because the specified entry and exit speeds have not changed.

Therefore, the total energy removed remains 128 J, and the load still receives 96 J under the stated resistance assumptions.

Doubling the magnetic field would increase the induced emf at a given fluid speed. With unchanged resistance, it would also increase the instantaneous current and magnetic braking force.

The fluid would therefore lose its kinetic energy more rapidly.

To retain the same exit speed, the fluid would need to spend less time in the magnetic field or travel through a shorter active channel. If the channel remained unchanged, the stronger braking could instead produce a lower exit speed.

The crucial distinction is between the rate of energy extraction and the total available energy.

A stronger magnetic field can change how quickly energy is extracted. It cannot create additional energy.

07What to understand next

An MHD generator brings together three ideas:

  • The magnetic force on moving charges produces charge separation and an induced voltage.
  • Current flowing through the conducting fluid produces a magnetic braking force.
  • The energy delivered to the electrical circuit comes from the energy driving the fluid.

The most useful next step is to study the feedback between the electrical load and fluid velocity. Once the load changes the current, the current changes the braking force, and the braking force changes the induced emf.

That interaction is what turns the simple equation \(\mathcal E=Bud\) into a complete engineering problem.