tutorgum
Try a Class

Photon Antibunching: How Timing Reveals Nonclassical Light

Learn how time-correlated photon detections reveal photon antibunching and why suppressed coincidences provide evidence of nonclassical light. Explore the HBT experiment, interpret correlation measurements, and understand the limitations of real single-photon sources.

Imagine two light sources that each produce an average of 100,000 detected photons per second. One is a dim laser. The other is light emitted by a single atom. If you measure only their average brightness, they might look identical.

Now record the exact arrival time of every photon. Does detecting one photon make another detection more or less likely a few nanoseconds later?

This timing pattern can reveal something that average brightness cannot: whether the light behaves like a classical electromagnetic field or has genuinely nonclassical photon statistics.

Photon antibunching is an extension topic beyond the required content of the NSW Year 12 Physics 2025 syllabus. We’ll use the syllabus’s Nature of light topic as our starting point, but this material is additional reading, not an HSC assessment requirement.

01The photon model: energy is not the whole story

In Year 12 Physics, you’ve studied the particle model of light. Light can be detected as individual photons, each carrying a discrete amount of energy.

The energy of a photon is:

\[ E=hf \]

where:

  • \(E\) is the energy of one photon, measured in joules (J).
  • \(h\) is Planck’s constant, \(6.626\times10^{-34}\,\mathrm{J\,s}\).
  • \(f\) is the frequency of the electromagnetic radiation, measured in hertz (Hz).

The frequency determines the energy carried by each photon. The intensity of a beam, at a fixed frequency, is related to how many photons arrive per second per unit area.

This gives us an important distinction:

  • Increasing the frequency increases the energy of each photon.
  • Increasing the intensity increases the average photon arrival rate.

If you dim a laser, you reduce its average photon output. You don’t change the energy of each photon.

But here’s the interesting part: dimming a laser doesn’t guarantee that photons arrive one at a time.

A laser can produce a random sequence of photon detections. Sometimes two photons arrive close together. Sometimes there is a longer gap. Even a very weak laser can produce closely spaced photon detections.

A source that genuinely suppresses closely spaced photon arrivals behaves differently.

Two aligned photon-detection timelines span the same observation period and each contain nine detections. The weak coherent laser shows random arrivals and closely spaced pairs, while the single-photon emitter shows regularly separated detections.
Both records contain nine detections over the same interval, yet only the single-photon source suppresses unusually close arrivals.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The difference isn’t their average brightness. It’s the statistical relationship between successive detections.

This is what photon antibunching allows us to investigate.

If you want to revisit the particle model of light first, tutorgum’s Compton Scattering: Photon Momentum and Wavelength Shifts explores another important consequence of treating light as individual photons.

02Why a single emitter produces antibunching

Consider an atom that can occupy two energy states:

  • A ground state, with lower energy.
  • An excited state, with higher energy.

An external energy source, such as a laser, can excite the atom. When the atom returns to its ground state, it can release the energy difference as a photon.

The emitted photon’s energy is equal to the difference between the two atomic energy levels.

What happens immediately after that photon is emitted?

The atom has returned to its ground state. It cannot immediately emit another photon through the same transition. It must first be excited again.

This creates a natural separation between successive emission events.

The important point is that the emitter has to be reset before it can produce another photon.

A useful analogy is a one-shot ticket dispenser. It can issue one ticket, but it must be reloaded before issuing the next. The first ticket changes the state of the machine, temporarily preventing another ticket from appearing.

The analogy isn’t exact. An atomic emitter doesn’t have a mechanical reloading process or a fixed waiting time. Its excitation and emission are governed by quantum probabilities.

The waiting time is therefore not necessarily identical for every photon.

However, immediately after an emission, the probability of another emission is strongly suppressed. As the emitter becomes excited again, that probability increases.

This produces photon antibunching.

The effect was observed experimentally in 1977 by H. J. Kimble, M. Dagenais, and L. Mandel. They studied fluorescence from sodium atoms continuously excited by a laser and found that the photoelectric detection events were antibunched.

Their result provided important evidence that the emitted light required a quantum description.

The original research is available in Photon Antibunching in Resonance Fluorescence, Physical Review Letters (1977).

03How do we measure photon antibunching?

We need more than a detector that simply counts photons.

We need to know when photons arrive and whether detections at different times are correlated.

The standard method uses a Hanbury Brown-Twiss arrangement, usually shortened to HBT.

The Hanbury Brown-Twiss experiment

The arrangement has four main components:

  1. A light source being investigated.
  2. A 50:50 beam splitter.
  3. Two separate photon detectors.
  4. An electronic timing system that records and compares detection times.

Light from the source enters the beam splitter, which directs photons into two separate output paths.

Detector A receives one output, and detector B receives the other.

One important detail: the beam splitter does not divide an individual photon into two half-photons.

For an ideal 50:50 beam splitter, an individual photon has equal probabilities of leaving through either output. A detection event occurs in one detector or the other.

The two detectors allow us to investigate whether separate photons arrive close together.

Here’s how the measurement works.

Step 1: Detector A registers a photon at time \(t_A\).

Step 2: The timing system checks when detector B registers another photon.

Step 3: It calculates the time difference between the two detections:

\[ \tau=t_B-t_A \]

Here, \(\tau\) is the time delay between the detections, measured in seconds.

A positive value means detector B registered its photon after detector A. A negative value means the reverse.

Step 4: The experiment repeats this process many times, recording the number of detection pairs for different time delays.

The result is a histogram of coincidence counts against time delay.

A coincidence is a pair of detections occurring within a specified time interval. The experiment records how frequently these pairs occur at different delays.

The shape of the histogram reveals the statistical behaviour of the light.

04Understanding the correlation function

A histogram gives us a visual pattern, but we need a numerical quantity to compare different sources.

This quantity is called the normalised second-order correlation function:

\[ g^{(2)}(\tau) = \frac{C(\tau)}{C_{\mathrm{uncorr}}} \]

where:

  • \(g^{(2)}(\tau)\) is the normalised second-order correlation at time delay \(\tau\).
  • \(C(\tau)\) is the measured coincidence rate in a time bin around delay \(\tau\).
  • \(C_{\mathrm{uncorr}}\) is the expected coincidence rate if the two detection streams were statistically independent.

The uncorrelated rate can be estimated using coincidences at sufficiently long delays, or calculated from the average detection rates.

The normalisation is important.

It means we’re not simply asking how many photons were detected. We’re comparing the observed number of photon pairs with how many pairs we would expect if the detections were independent.

For a steady source whose correlations disappear at long delays:

\[ g^{(2)}(\tau)\longrightarrow 1 \]

as the time delay becomes sufficiently large.

The value at zero delay, \(g^{(2)}(0)\), is particularly useful.

It tells us how strongly simultaneous or nearly simultaneous photon detections are suppressed or enhanced compared with the uncorrelated expectation.

Three different types of light

Consider three idealised light sources.

Light source\(g^{(2)}(0)\)Behaviour
Coherent laser1Uncorrelated photon arrivals
Single-mode thermal light2Photon bunching
Ideal single-photon state0Complete suppression of photon pairs

These are ideal reference cases. Real sources can produce intermediate values.

Let’s examine the three behaviours.

1. Coherent light: \(g^{(2)}(0)=1\)

An ideal laser produces coherent light with Poisson photon-number statistics.

Its photon detections are uncorrelated in the second-order sense. Detecting one photon does not change the probability of detecting another at a short time delay.

The correlation function remains at 1.

2. Bunched light: \(g^{(2)}(0)>1\)

Thermal light, such as ideal single-mode blackbody radiation, displays photon bunching.

Photons are more likely to be detected close together than they would be if their arrival times were independent.

The histogram therefore contains a peak around zero delay.

This occurs because thermal light has intensity fluctuations. Periods of higher intensity tend to produce more detections close together.

3. Antibunched light: \(g^{(2)}(0)<1\)

Antibunched light has the opposite behaviour.

Immediately after one photon is detected, another photon is less likely to be detected than the uncorrelated baseline predicts.

The histogram contains a dip around zero delay.

For an ideal single-photon emitter:

\[ g^{(2)}(0)=0 \]

There are no simultaneous photon pairs from the ideal single-photon state.

For a continuously pumped single emitter, the correlation generally rises from its minimum at zero delay towards 1 as the emitter is re-excited.

This central dip is the key experimental signature of photon antibunching.

05Why does antibunching prove that light is nonclassical?

We’ve identified a pattern. But why is it evidence for quantum behaviour?

The answer comes from a restriction on classical light.

Imagine describing a light beam using an ordinary classical electromagnetic field with a fluctuating intensity \(I\).

Its normalised zero-delay intensity correlation is:

\[ g_{\mathrm{classical}}^{(2)}(0) = \frac{\langle I^2\rangle} {\langle I\rangle^2} \]

Here, the angle brackets represent an average over time or repeated measurements.

We can rewrite this expression using the variance of intensity:

\[ g_{\mathrm{classical}}^{(2)}(0) = 1+ \frac{\operatorname{Var}(I)} {\langle I\rangle^2} \]

Variance measures how much a quantity fluctuates around its average.

A fundamental mathematical property is that variance cannot be negative:

\[ \operatorname{Var}(I)\geq 0 \]

Therefore:

\[ \boxed{g_{\mathrm{classical}}^{(2)}(0)\geq 1} \]

This is the classical bound.

A classical fluctuating intensity can produce bunching or uncorrelated detections, but it cannot produce a normalised zero-delay correlation below 1.

Quantum light can violate this restriction.

If an experiment measures:

\[ g^{(2)}(0)<1 \]

after accounting for background and detector effects, the photon statistics cannot be explained by a classical random-intensity model.

The light is nonclassical.

This is the central significance of photon antibunching. It isn’t simply an unusual arrangement of photon detections. It is an experimentally measurable result that a classical model cannot reproduce.

06Worked example: interpreting an antibunching histogram

A researcher investigates a continuously emitting quantum source using an HBT arrangement.

The long-delay histogram bins contain an average of 250 coincidences each. The zero-delay bin contains only 45 coincidences.

Assume the measurements use identical bin widths and observation times, and that background contributions are negligible.

Calculate \(g^{(2)}(0)\) and determine whether the source exhibits antibunching.

Step 1

The long-delay bins provide the expected coincidence count when the detections are independent.

Therefore:

\[ C_{\mathrm{uncorr}}=250 \]

Step 2

Use:

\[ g^{(2)}(0)= \frac{C(0)}{C_{\mathrm{uncorr}}} \]

Substitute the measured values:

\[ g^{(2)}(0)=\frac{45}{250} \]

\[ \boxed{g^{(2)}(0)=0.18} \]

Step 3

The measured value is below 1.

The source produces only 18% of the zero-delay coincidences expected from independent photon detections.

This is evidence of strong photon antibunching and nonclassical light.

Notice that 0.18 does not mean there is an 18% chance of a photon being emitted. It is a normalised comparison of coincidence rates.

07Worked example: calculating the expected coincidences

Now suppose the experiment doesn’t provide a long-delay baseline.

Instead, we know the average detection rates of the two detectors.

The following hypothetical measurements are recorded:

  • Detector A: \(18\,000\) detections per second.
  • Detector B: \(24\,000\) detections per second.
  • Measurement duration: \(60\,\mathrm{s}\).
  • Histogram bin width: \(5\,\mathrm{ns}\).
  • Measured zero-delay coincidences: 32.

Assume the source is steady and that independent detection events provide the correct uncorrelated baseline.

Calculate \(g^{(2)}(0)\).

Step 1

For two independent detection streams, the expected number of coincidences in one delay bin is:

\[ C_{\mathrm{uncorr}}=R_A R_B T\Delta t \]

where:

  • \(R_A\) is the detection rate of detector A.
  • \(R_B\) is the detection rate of detector B.
  • \(T\) is the total measurement duration.
  • \(\Delta t\) is the histogram bin width.

Convert the bin width into seconds:

\[ 5\,\mathrm{ns}=5\times10^{-9}\,\mathrm{s} \]

Step 2

\[ \begin{aligned} C_{\mathrm{uncorr}} &=(1.8\times10^4)(2.4\times10^4)\\ &\quad\times60\times(5\times10^{-9}) \end{aligned} \]

Therefore:

\[ C_{\mathrm{uncorr}}=129.6 \]

We expect approximately 130 coincidences per bin if the detection streams are independent.

Step 3

The measured zero-delay bin contains 32 coincidences.

\[ g^{(2)}(0)=\frac{32}{129.6} \]

\[ \boxed{g^{(2)}(0)\approx0.25} \]

Step 4

The zero-delay coincidence rate is approximately one-quarter of the uncorrelated expectation.

Since \(g^{(2)}(0)<1\), the result is consistent with photon antibunching.

The important experimental skill here is knowing how to establish the correct baseline. A low coincidence count by itself doesn’t prove antibunching. It must be compared with the expected count for independent detections.

08What can make an antibunching dip harder to observe?

Real experiments aren’t perfect. Even a genuine single-photon emitter can produce a measured correlation value much closer to 1 than its intrinsic value.

Three limitations are particularly important.

1. Background light fills the dip

Suppose a single-photon emitter produces strongly antibunched light, but the detector also receives unrelated background photons.

These background detections can occur close together, even when the emitter itself is not producing a pair.

Consequently, the measured histogram contains extra coincidences around zero delay.

The dip becomes shallower.

For an independent Poissonian background, the measured correlation can be related to the intrinsic signal correlation using:

\[ g_{\mathrm{meas}}^{(2)}(0) = 1-\rho^2 \left[ 1-g_{\mathrm{signal}}^{(2)}(0) \right] \]

where:

  • \(g_{\mathrm{meas}}^{(2)}(0)\) is the measured zero-delay correlation.
  • \(g_{\mathrm{signal}}^{(2)}(0)\) is the intrinsic correlation of the emitter.
  • \(\rho\) is the fraction of detected light that comes from the actual emitter.

This expression assumes that the background is independent of the signal, has Poissonian statistics, and contributes equally to both detection channels.

Notice that the square of \(\rho\) appears.

The antibunching signature depends on detecting pairs of photons from the signal. Adding unrelated background reduces the fraction of detected pairs that can reveal this behaviour.

2. Detector timing resolution can hide the dip

Photon detectors don’t measure arrival times with perfect precision.

Their timing resolution is limited by the detector response and associated electronics.

If the antibunching dip is extremely narrow, poor timing resolution can blur it.

Some events that genuinely occur at slightly different times may be recorded within the same timing bin. This makes the measured central value larger than the true minimum.

The detector timing resolution therefore needs to be sufficiently short compared with the timescale of the antibunching behaviour.

3. Detector dead time can create misleading results

A detector usually needs a short recovery period after registering a photon. During this interval, it cannot register another event.

This is called detector dead time.

Suppose you use only one detector and try to measure correlations between successive detections. The detector itself may suppress closely spaced clicks.

You could mistakenly interpret this artificial suppression as photon antibunching.

The standard two-detector HBT arrangement helps avoid this particular problem. A detection in detector A does not prevent detector B from registering another photon during detector A’s recovery period.

However, detector cross-talk, background light, timing errors, and other instrumental effects still need to be considered.

A convincing antibunching measurement must show that the central dip comes from the light source rather than the measurement equipment.

09What does \(g^{(2)}(0)\) actually tell us about photon numbers?

So far, we’ve described antibunching using detection times.

We can also understand it by considering how many photons are present in each pulse of light.

Let \(n\) represent the number of photons in one pulse.

For an ideal pulsed source, the zero-delay correlation can be written as:

\[ g^{(2)}(0) = \frac{\langle n(n-1)\rangle} {\langle n\rangle^2} \]

The angle brackets represent averages over many pulses.

Why does the expression contain \(n(n-1)\)?

Because it counts pairs of distinct photons.

Consider three situations.

Situation 1: Exactly one photon per pulse

If every pulse contains exactly one photon:

\[ n=1 \]

Therefore:

\[ n(n-1)=1(0)=0 \]

There are no photon pairs within a pulse.

Consequently:

\[ g^{(2)}(0)=0 \]

Situation 2: Sometimes one photon, sometimes no photon

Suppose a source produces one photon in only 10% of its pulses. The other 90% contain no photons.

Now the source has a much lower average output.

However, every pulse still contains either zero or one photon.

Therefore, \(n(n-1)\) is always zero, and:

\[ g^{(2)}(0)=0 \]

This is an important result.

A source can exhibit perfect antibunching even if it produces photons on only a small fraction of its excitation pulses.

Situation 3: Exactly two photons per pulse

Suppose every pulse contains exactly two photons.

Then:

\[ \langle n\rangle=2 \]

and:

\[ \langle n(n-1)\rangle=2 \]

Therefore:

\[ g^{(2)}(0)=\frac{2}{2^2} \]

\[ \boxed{g^{(2)}(0)=0.5} \]

The source still has \(g^{(2)}(0)<1\), despite containing two photons in every pulse.

This shows why we must be careful with the interpretation.

Antibunching and nonclassical photon statistics indicate suppressed pair fluctuations. They don’t automatically guarantee that a source emits exactly one photon every time it is triggered.

There is another important consequence.

Suppose every emitted photon has an independent probability \(\eta\) of being detected, where \(\eta\) is the overall detection efficiency.

The average detected photon number is reduced by a factor of \(\eta\). The number of detected pairs is reduced by a factor of \(\eta^2\).

These factors cancel in the normalised correlation function.

Therefore, uniform independent detection losses do not change the ideal value of \(g^{(2)}(0)\).

This makes antibunching measurements useful for characterising sources even when some photons are inevitably lost.

However, it also means that antibunching alone cannot tell us how many photons were emitted but failed to reach the detectors.

That distinction becomes important in the final question.

10Further reading

The following sources provide the scientific foundations for this extension topic:

11Questions and solutions

The following questions progress from interpreting experimental data to reasoning about multiple emitters, background contamination, and the limitations of photon-correlation measurements.

Question 1

A researcher measures the second-order correlation function of a continuously emitting light source.

The following values are obtained:

Time delay, \(\tau\)\(g^{(2)}(\tau)\)
0 ns0.22
10 ns0.65
50 ns0.98
100 ns1.00

Identify the behaviour exhibited by the source.

Explain what happens to the probability of detecting a second photon immediately after the first photon is detected. Why does this result provide evidence of nonclassical light?

Solution 1

The source exhibits photon antibunching and produces nonclassical light.

The key observation is:

\[ g^{(2)}(0)=0.22<1 \]

This means that the measured zero-delay coincidence rate is only 22% of the rate expected for statistically independent detections.

As the time delay increases, the correlation rises towards 1.

This indicates that detecting one photon suppresses the probability of detecting another immediately afterwards. The suppression gradually disappears as the emitter recovers and becomes capable of producing another photon.

For a classical fluctuating intensity:

\[ g^{(2)}(0)\geq1 \]

The measured value of 0.22 violates this classical bound.

Therefore, the source’s photon statistics cannot be explained using a classical random-intensity model.

The recovery towards 1 is also consistent with the physical mechanism of a single emitter that must be re-excited after emitting a photon.

Question 2

A researcher uses an HBT arrangement to investigate an unknown light source.

The following measurements are recorded:

  • Detector A records \(20\,000\) photons per second.
  • Detector B records \(15\,000\) photons per second.
  • The measurement lasts \(30\,\mathrm{s}\).
  • Each histogram bin has a width of \(4\,\mathrm{ns}\).
  • The central histogram bin contains 9 coincidences.

Assume the source is stationary, the detector rates remain constant, and background contributions are negligible.

(a) Calculate the expected number of coincidences in a single bin if the detection streams are independent.

(b) Calculate \(g^{(2)}(0)\).

(c) Explain what the result tells us about the source.

Solution 2

(a) The expected number of independent coincidences is 36.

Use:

\[ C_{\mathrm{uncorr}}=R_A R_B T\Delta t \]

Substitute:

\[ \begin{aligned} C_{\mathrm{uncorr}} &=(2.0\times10^4)(1.5\times10^4)\\ &\quad\times30\times(4\times10^{-9}) \end{aligned} \]

Therefore:

\[ \boxed{C_{\mathrm{uncorr}}=36} \]

The independent detection streams would produce approximately 36 coincidences in the central bin.

(b) The normalised correlation is 0.25.

The measured central bin contains only 9 coincidences.

\[ g^{(2)}(0)= \frac{C(0)}{C_{\mathrm{uncorr}}} \]

\[ g^{(2)}(0)=\frac{9}{36} \]

\[ \boxed{g^{(2)}(0)=0.25} \]

(c) The result indicates photon antibunching.

The zero-delay coincidence rate is only one-quarter of the uncorrelated expectation.

Since:

\[ 0.25<1 \]

the measurement is consistent with nonclassical photon statistics.

The source suppresses closely spaced photon detections compared with a statistically independent photon stream.

In an actual experiment, the uncertainty in the coincidence counts must also be considered. A result below 1 is only convincing evidence when the difference is sufficiently large compared with the measurement uncertainty.

Question 3

A single-photon emitter has an intrinsic zero-delay correlation of:

\[ g_{\mathrm{signal}}^{(2)}(0)=0.05 \]

However, the detected light contains an independent Poissonian background.

The signal from the emitter contributes 60% of the total detected intensity.

The remaining 40% comes from background light.

Assume the signal and background are statistically independent, and that both detectors receive the same signal fraction.

(a) Calculate the measured value of \(g^{(2)}(0)\).

(b) A student claims that a measured value substantially above 0.05 means the emitter has stopped producing antibunched light. Evaluate this conclusion.

Solution 3

(a) The measured correlation is approximately 0.66.

For an independent Poissonian background, we use:

\[ g_{\mathrm{meas}}^{(2)}(0) = 1-\rho^2 \left[ 1-g_{\mathrm{signal}}^{(2)}(0) \right] \]

The signal fraction is:

\[ \rho=0.60 \]

Substitute:

\[ g_{\mathrm{meas}}^{(2)}(0) = 1-(0.60)^2(1-0.05) \]

Calculate:

\[ g_{\mathrm{meas}}^{(2)}(0) = 1-0.36(0.95) \]

\[ =1-0.342 \]

Therefore:

\[ \boxed{g_{\mathrm{meas}}^{(2)}(0)=0.658} \]

(b) The student’s conclusion is incorrect.

The emitter can still be producing strongly antibunched light. The higher measured correlation is caused by the additional background detections.

The background introduces unrelated coincidences, including coincidences close to zero delay.

This fills the central dip and increases the measured value.

Importantly:

\[ 0.658<1 \]

The measured result still demonstrates antibunching.

The intrinsic source value is 0.05, while the detector measures a mixture of signal and background with a value of approximately 0.66.

This is why isolating the emitter and reducing background light are important when characterising single-photon sources.

Question 4

Two independent, identical single-photon emitters are positioned close together.

Their emitted light is collected into the same optical detection system.

Each emitter individually has:

\[ g^{(2)}(0)=0 \]

Assume:

  • Both emitters have the same average intensity \(S\).
  • Each emitter is individually ideal and produces no same-emitter photon pairs at zero delay.
  • The emitters are statistically independent.
  • Their light is combined incoherently, with no collective emission effects.

Determine the zero-delay correlation of the combined light.

Explain why combining two ideal single-photon emitters does not necessarily produce \(g^{(2)}(0)=0\).

Solution 4

The combined source has:

\[ \boxed{g^{(2)}(0)=0.5} \]

The tempting answer is zero.

After all, neither emitter can produce two photons simultaneously through its ideal single-photon transition.

However, this ignores an important possibility: a photon from the first emitter and a photon from the second emitter can arrive close together.

The two emitters are independent, so their cross-emitter photon pairs are allowed.

Let the average intensity from each emitter be \(S\).

The total average intensity is:

\[ I_{\mathrm{total}}=2S \]

The total zero-delay pair contribution contains two cross-emitter terms:

  • A photon from emitter 1 followed by one from emitter 2.
  • A photon from emitter 2 followed by one from emitter 1.

Each emitter’s individual contribution is zero because it cannot produce a same-emitter pair at zero delay.

Therefore, the combined pair contribution is proportional to:

\[ 2S^2 \]

The normalised correlation is:

\[ g^{(2)}(0) = \frac{2S^2}{(2S)^2} \]

Simplifying:

\[ g^{(2)}(0)=\frac{2S^2}{4S^2} \]

\[ \boxed{g^{(2)}(0)=0.5} \]

The result is still below 1, so the combined light remains nonclassical.

The important distinction is that antibunching from each emitter does not prevent coincidences between different emitters.

More generally, for \(N\) identical, independent, equally bright ideal single-photon emitters:

\[ g^{(2)}(0)=1-\frac{1}{N} \]

As the number of independent emitters increases, the combined zero-delay correlation approaches 1.

This means that a measured antibunching dip can also provide information about how many independent emitters contribute to the detected light.

Question 5

A laboratory investigates a pulsed light source using an HBT arrangement.

The source receives one excitation pulse every \(50\,\mathrm{ns}\).

The following observations are recorded:

  • Detector A registers a photon on 5.0% of excitation pulses.
  • Detector B registers a photon on 5.0% of excitation pulses.
  • No excitation pulse produces simultaneous detections in both detectors.
  • The idealised normalised zero-delay correlation is therefore \(g^{(2)}(0)=0\).

The laboratory concludes:

“The source emits exactly one photon on every excitation pulse. We have demonstrated a deterministic single-photon source.”

Is this conclusion justified?

Construct two different physical models that produce exactly the same detector observations:

  • One model in which the source really does emit one photon on every excitation pulse.
  • Another model in which the source emits a photon on only some excitation pulses.

Calculate the detection probabilities for both models and explain what additional information is needed to distinguish them.

Assume a 50:50 beam splitter, independent detection losses, no dark counts, and statistically independent excitation pulses.

Solution 5

No. The measurements establish suppression of same-pulse photon coincidences, but they do not prove that the source emits exactly one photon on every excitation pulse.

Two physically different models can produce identical detector records.

Model 1: One photon emitted on every pulse, with detection losses

Suppose the emitter produces exactly one photon for every excitation pulse.

However, the overall probability that an emitted photon is collected and detected is only 10%.

The 50:50 beam splitter directs the detected photons equally between the two detectors.

Therefore, the probability of detector A registering a photon is:

\[ P(A)=0.10\times0.50 \]

\[ \boxed{P(A)=0.05} \]

Similarly:

\[ \boxed{P(B)=0.05} \]

Because only one photon is emitted per pulse, both detectors cannot register that same photon.

The remaining 90% of pulses produce no detection because the photon is lost before detection.

The observations are therefore:

  • Detector A clicks on 5% of pulses.
  • Detector B clicks on 5% of pulses.
  • Neither detector clicks on 90% of pulses.
  • Both detectors never click on the same pulse.

This model agrees with the experiment.

Model 2: One photon emitted on only 10% of pulses

Now consider a different source.

It emits exactly one photon on 10% of excitation pulses and emits nothing on the remaining 90%.

Assume perfect collection and detection efficiency.

When a photon is emitted, the 50:50 beam splitter directs it towards detector A or detector B with equal probability.

Therefore:

\[ P(A)=0.10\times0.50 \]

\[ \boxed{P(A)=0.05} \]

Likewise:

\[ \boxed{P(B)=0.05} \]

Again, no individual pulse can produce simultaneous detections in both detectors because only one photon is emitted.

The remaining 90% of excitation pulses contain no photon.

This model produces exactly the same detector observations as Model 1.

Why can’t the HBT measurement distinguish them?

The key is the difference between an emitted photon and a detected photon.

In Model 1, a photon is emitted on every pulse, but 90% of emitted photons are lost.

In Model 2, a photon is emitted on only 10% of pulses, but every emitted photon is detected.

Both produce the same detected photon statistics.

The HBT measurement establishes that detected photons are not appearing in same-pulse pairs. It does not independently measure how many photons were emitted but lost.

To distinguish the models, the laboratory needs an independent calibration of the overall collection and detection efficiency.

For example, if the overall efficiency is independently established as 10%, the observed 10% total detection probability is consistent with one photon being emitted on every pulse.

If the overall efficiency is 100%, the same detection probability instead indicates that the source emits on only 10% of pulses.

The distinction is important:

  • Photon antibunching measures suppression of photon pairs.
  • Source brightness measures how frequently photons are produced.
  • Collection and detection efficiency measure how many emitted photons are actually observed.

These are different properties.

A source can exhibit perfect antibunching while still producing photons very infrequently.


Photon antibunching gives us a way to investigate the quantum statistics of light using measurable detection times rather than relying only on its average intensity.

Once you can interpret \(g^{(2)}(\tau)\), the next step is to investigate what makes a practical single-photon source useful. That requires looking beyond antibunching to photon emission probability, collection efficiency, background suppression, and photon indistinguishability.

These measurements are central to developing reliable single-photon sources for quantum communication and quantum information technologies.