How to Write Galvanic Cell Notation from a Diagram
Learn how to turn galvanic cell diagrams into correct cell notation by identifying the anode, cathode, electrode reactions, and ion movement. Includes worked examples, standard cell potential calculations, common mistakes, and challenging HSC Chemistry practice questions with solutions.
A copper electrode is drawn on the left of a galvanic-cell diagram, and an iron electrode is drawn on the right. The two metals sit in solutions containing their own ions, with a salt bridge between the beakers. A voltmeter shows that copper is the positive electrode.
Which metal should come first when you write the cell notation?
Iron, even though it’s drawn on the right.
For a galvanic cell operating spontaneously, write the anode (where oxidation occurs) on the left and the cathode (where reduction occurs) on the right. The correct cell notation is:
\[ \ce{Fe(s) | Fe^2+(aq) || Cu^2+(aq) | Cu(s)} \]
The single vertical lines separate different phases. The double line represents the salt bridge or liquid junction.
That’s the essential method: identify the reactions first, then write the notation. Never copy the physical left-to-right order of the beakers without checking which electrode is the anode.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
01Read the apparatus before writing the symbols
Cell notation is a compressed description of an experiment. To write it correctly, you need to understand what happens in the two beakers.
Take the iron-copper cell from the opening.
In the copper beaker, a copper metal strip touches a solution containing \(\mathrm{Cu}^{2+}\) ions. In the iron beaker, an iron metal strip touches a solution containing \(\mathrm{Fe}^{2+}\) ions.
The metals are connected by an external conducting circuit. The solutions are connected by a salt bridge containing an electrolyte such as potassium nitrate, \(\ce{KNO3}\).
These connections have different jobs.
What happens at the electrodes?
Suppose both solutions are initially at standard concentrations and the electrodes are allowed to supply current through an external load.
Predict which metal should gradually lose mass.
Iron loses mass because iron atoms are oxidised into dissolved iron(II) ions:
\[ \ce{Fe(s) -> Fe^2+(aq) + 2e-} \]
Oxidation means losing electrons. The iron electrode is therefore the anode.
At the copper electrode, copper(II) ions gain those electrons and become solid copper:
\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]
Reduction means gaining electrons. The copper electrode is the cathode.
The overall reaction is:
\[ \ce{Fe(s) + Cu^2+(aq) -> Fe^2+(aq) + Cu(s)} \]
As the cell operates, iron dissolves, while copper is deposited. Electrons move through the external circuit from iron to copper.
A high-resistance voltmeter draws very little current, so you wouldn’t expect an obvious mass change during a quick voltage measurement. The reactions above describe the direction in which the cell can operate when current flows.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Why does the salt bridge matter?
If iron produces \(\mathrm{Fe}^{2+}\) ions, its solution tends to accumulate positive charge. Meanwhile, the copper solution loses positive ions as \(\mathrm{Cu}^{2+}\) becomes copper metal.
Without a way to compensate for this charge imbalance, sustained electron transfer would quickly stop.
The salt bridge provides an ionic connection.
For a potassium nitrate bridge in this idealised cell:
- \(\ce{NO3-}\) ions migrate towards the iron half-cell, where positive ions are being produced.
- \(\mathrm{K}^{+}\) ions migrate towards the copper half-cell, where positive ions are being consumed.
Electrons travel through the external conductor. Ions carry charge through the bridge and solutions.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
There’s a useful experimental test here.
Imagine starting with only the external wire connecting the two electrodes, leaving out the salt bridge. You might still get a transient electrical response, but the cell cannot sustain normal galvanic current because the ionic circuit is incomplete.
Adding the salt bridge corrects that problem. It doesn’t supply electrons; it allows charge balance to be maintained while the electrode reactions continue.
The precise movement of ions in a real cell can be more complicated because several ions may move simultaneously. The anion-to-anode and cation-to-cathode rule describes the expected salt-bridge migration in these simple galvanic-cell models.
02Turn the diagram into cell notation
Once you’ve identified the chemistry, use this sequence.
- Identify both electrodes and their solutions. Record the metals, dissolved ions, gases, and any inert electrodes.
- Find oxidation and reduction. Use the electrode reactions, observed changes, measured polarity, or standard reduction potentials if the conditions are standard.
- Write the anode half-cell first. Start with its conducting electrode and move towards the solution and junction.
- Write the cathode half-cell second. Move from the solution towards its conducting electrode, ending with the electrode itself.
This gives the usual structure:
\[ \underbrace{\text{anode | ions}}_{\text{oxidation}} \;||\; \underbrace{\text{ions | cathode}}_{\text{reduction}} \]
What do the lines and commas mean?
| Symbol | Meaning | When to use it |
|---|---|---|
| \(\mid\) | Boundary between different phases | A metal electrode touching an aqueous solution |
| \(\parallel\) | Salt bridge or liquid junction | Between the two half-cells in ordinary HSC notation |
| Comma | Species in the same phase | Two dissolved ions sharing one solution |
The lines don’t represent wires. In particular, the double line is not the external connection carrying electrons.
For the iron-copper cell, the iron electrode sits at the beginning of the notation because it’s the anode. The copper electrode sits at the end because it’s the cathode.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
A reversed line can be written mathematically, but it corresponds to the opposite reaction direction and reverses the sign assigned to the cell potential. It doesn’t reverse the actual chemistry just because you’ve rewritten the symbols.
For an HSC question asking for the spontaneous galvanic-cell notation, use the anode-left, cathode-right convention.
03Worked example: Silver on the left, nickel on the right
A galvanic-cell diagram shows a silver electrode in a solution containing \(\mathrm{Ag}^{+}\) ions on the left. A nickel electrode in a solution containing \(\mathrm{Ni}^{2+}\) ions is drawn on the right.
The two solutions are connected by a potassium nitrate salt bridge, and the electrodes are connected to a voltmeter.
All species are under standard conditions at \(25^\circ\mathrm{C}\).
The supplied standard reduction potentials are:
| Reduction half-reaction | \(E^\circ_{\mathrm{red}}\) |
|---|---|
| \(\ce{Ag+ + e- -> Ag}\) | \(+0.80\ \mathrm{V}\) |
| \(\ce{Ni^2+ + 2e- -> Ni}\) | \(-0.25\ \mathrm{V}\) |
Write the cell notation, calculate the standard cell potential, and predict the movement of ions in the salt bridge.
Step 1
Silver has the more positive reduction potential, so silver ions are reduced at the cathode:
\[ \ce{Ag+(aq) + e- -> Ag(s)} \]
Nickel is oxidised at the anode:
\[ \ce{Ni(s) -> Ni^2+(aq) + 2e-} \]
Notice that nickel is the anode even though it’s drawn on the right.
Step 2
Nickel produces two electrons per atom, but each silver ion accepts only one. Multiply the silver reduction equation by two:
\[ \ce{2Ag+(aq) + 2e- -> 2Ag(s)} \]
The overall reaction is:
\[ \ce{Ni(s) + 2Ag+(aq) -> Ni^2+(aq) + 2Ag(s)} \]
Step 3
Start with nickel, the anode. Follow it with nickel ions, the salt bridge, silver ions, and finally the silver cathode:
\[ \ce{Ni(s) | Ni^2+(aq) || Ag+(aq) | Ag(s)} \]
This is the correct notation even though the physical drawing places silver first.
Step 4
Use the two tabulated reduction potentials:
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{Ag}}-E^\circ_{\mathrm{Ni}}\\ &=0.80-(-0.25)\\ &=+1.05\ \mathrm{V} \end{aligned} \]
Here, \(E^\circ_{\mathrm{Ag}}\) and \(E^\circ_{\mathrm{Ni}}\) are the standard reduction potentials of their respective half-cells, while \(E^\circ_{\mathrm{cell}}\) is the standard potential of the complete cell. All three are measured in volts, \(\mathrm{V}\).
The positive value confirms that the reaction as written is spontaneous under standard conditions.
We multiplied the silver half-equation by two to balance electrons. We did not multiply its reduction potential by two. Electrode potential isn’t proportional to the amount of reaction.
Step 5
Nickel oxidation creates \(\mathrm{Ni}^{2+}\) ions, so nitrate ions migrate towards the nickel half-cell.
Silver reduction removes \(\mathrm{Ag}^{+}\) ions, so potassium ions migrate towards the silver half-cell.
The notation tells us where oxidation and reduction occur. Understanding those reactions then tells us the directions of electron transfer and salt-bridge ion migration.
For a closer explanation of why the more positive standard reduction potential identifies the cathode, see Reduction Potentials of Galvanic Half-Cells: HSC Chemistry.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
04Worked example: What if the electrode is platinum?
Not every half-cell contains a metal that takes part in the redox reaction.
Suppose a diagram shows a platinum electrode immersed in a mixture of \(\mathrm{Fe}^{3+}\) and \(\mathrm{Fe}^{2+}\) ions on the left.
On the right is a tin electrode immersed in a solution containing \(\mathrm{Sn}^{2+}\) ions.
A salt bridge connects the two solutions. All species are at standard conditions.
The supplied standard reduction potentials are:
| Reduction half-reaction | \(E^\circ_{\mathrm{red}}\) |
|---|---|
| \(\ce{Fe^3+ + e- -> Fe^2+}\) | \(+0.77\ \mathrm{V}\) |
| \(\ce{Sn^2+ + 2e- -> Sn}\) | \(-0.14\ \mathrm{V}\) |
Write the cell notation and calculate the standard cell potential.
Step 1
The iron(III)/iron(II) couple has the more positive reduction potential, so iron(III) ions are reduced:
\[ \ce{Fe^3+(aq) + e- -> Fe^2+(aq)} \]
Tin is oxidised:
\[ \ce{Sn(s) -> Sn^2+(aq) + 2e-} \]
The platinum electrode does not become iron metal. It provides a conducting surface where electrons can transfer between the external circuit and the dissolved ions.
Step 2
Tin is the anode because oxidation occurs there.
Platinum is the cathode because the iron(III) reduction occurs at its surface.
The electrode’s material and the species undergoing reduction are not always the same substance.
Step 3
\[ \ce{Sn(s) | Sn^2+(aq) || Fe^3+(aq), Fe^2+(aq) | Pt(s)} \]
There are two important details.
First, platinum appears at the far right because it’s the conducting electrode of the cathode half-cell.
Second, \(\mathrm{Fe}^{3+}\) and \(\mathrm{Fe}^{2+}\) are separated by a comma. Both are dissolved in the same aqueous phase. There is no phase boundary between them.
Writing a single vertical line between those ions would incorrectly suggest they occupy separate phases.
Step 4
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{Fe^{3+}/Fe^{2+}}} -E^\circ_{\mathrm{Sn^{2+}/Sn}}\\ &=0.77-(-0.14)\\ &=+0.91\ \mathrm{V} \end{aligned} \]
The subscripts identify the two reduction couples. The result means the cell has a predicted standard potential of \(+0.91\ \mathrm{V}\) in its spontaneous direction.
The balanced overall reaction is:
\[ \ce{Sn(s) + 2Fe^3+(aq) -> Sn^2+(aq) + 2Fe^2+(aq)} \]
The tin electrode loses mass, while the platinum electrode isn’t consumed or plated with iron under this reaction. Its role is electrical, not stoichiometric.
This distinction is especially important when a diagram contains a graphite or platinum electrode surrounded by several dissolved reacting species.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
05What cell notation doesn’t tell you
A cell notation is a description of the chemical arrangement and reaction direction. It isn’t a complete record of the experimental conditions.
Two diagrams can have the same shorthand notation but different measured voltages.
Standard potential versus actual voltage
The standard cell potential, \(E^\circ_{\mathrm{cell}}\), is calculated using standard reduction potentials.
For HSC-style calculations at \(25^\circ\mathrm{C}\), or approximately \(298\ \mathrm{K}\), the usual reference conditions are:
| Condition | Standard reference |
|---|---|
| Aqueous species | \(1.0\ \mathrm{mol\ L^{-1}}\) concentration in the usual HSC approximation |
| Gases | \(100\ \mathrm{kPa}\), equivalent to \(1\ \mathrm{bar}\) |
| Pure solids and liquids | Present in their standard states |
| Temperature for typical tables | \(25^\circ\mathrm{C}\), approximately \(298\ \mathrm{K}\) |
Strictly, thermodynamic standard states are defined using activities rather than simply concentrations. Treating \(1.0\ \mathrm{mol\ L^{-1}}\) as the standard aqueous condition is the usual simplified model for school calculations.
The actual cell potential, \(E_{\mathrm{cell}}\), can differ because the concentrations, temperature, and other operating conditions may not match those used for the standard potentials.
A voltmeter measurement can also be influenced by current flow, internal resistance, electrode surfaces, and liquid-junction effects.
A negative voltmeter reading doesn’t necessarily mean the reaction is reversed
Suppose the silver-nickel cell from the first worked example has an ideal open-circuit potential of \(+1.05\ \mathrm{V}\).
Connect the red voltmeter lead to silver and the black lead to nickel. The meter displays approximately \(+1.05\ \mathrm{V}\).
Now swap the leads without changing either half-cell.
What should the meter display?
Approximately \(-1.05\ \mathrm{V}\).
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
A digital voltmeter reports the electrical potential at its red lead relative to its black lead:
\[ V_{\mathrm{display}}=V_{\mathrm{red}}-V_{\mathrm{black}} \]
Here, \(V_{\mathrm{red}}\) and \(V_{\mathrm{black}}\) are the electrical potentials of the two connected terminals, in volts.
Swapping the leads changes the sign of the displayed value. It doesn’t turn the nickel electrode into the cathode.
If the measured polarity disagrees with a prediction from standard reduction potentials, investigate the lead connections and actual solution conditions before rewriting the cell.
Under sufficiently different non-standard conditions, the direction favoured by a cell can genuinely differ from its standard-condition prediction. In that situation, measured electrode polarity is useful evidence of the actual operating direction.
For the experimental reasons behind voltage differences, see Why a Galvanic Cell’s Measured Voltage Differs from E°.
06Questions and solutions
Question 1
A galvanic-cell diagram shows a copper electrode in \(\mathrm{Cu}^{2+}\) solution on the left and a nickel electrode in \(\mathrm{Ni}^{2+}\) solution on the right.
The solutions are connected by a potassium nitrate salt bridge. All species are under standard conditions at \(25^\circ\mathrm{C}\).
The supplied standard reduction potentials are:
- \(\ce{Cu^2+ + 2e- -> Cu}\): \(+0.34\ \mathrm{V}\)
- \(\ce{Ni^2+ + 2e- -> Ni}\): \(-0.25\ \mathrm{V}\)
Write the cell notation, calculate \(E^\circ_{\mathrm{cell}}\), and state which way potassium and nitrate ions move in the salt bridge.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 1
The correct notation is \(\ce{Ni | Ni^2+ || Cu^2+ | Cu}\), the standard cell potential is \(+0.59\ \mathrm{V}\), nitrate ions migrate towards nickel, and potassium ions migrate towards copper.
The more positive reduction potential belongs to copper, making it the cathode:
\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]
Nickel is oxidised at the anode:
\[ \ce{Ni(s) -> Ni^2+(aq) + 2e-} \]
Including the physical states, the complete notation is:
\[ \ce{Ni(s) | Ni^2+(aq) || Cu^2+(aq) | Cu(s)} \]
Calculate the standard potential:
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{cathode}} -E^\circ_{\mathrm{anode}}\\ &=0.34-(-0.25)\\ &=+0.59\ \mathrm{V} \end{aligned} \]
The positive result confirms the predicted spontaneous direction under standard conditions.
At the anode, nickel produces positive \(\mathrm{Ni}^{2+}\) ions, so \(\ce{NO3-}\) migrates towards the nickel half-cell.
At the cathode, positive \(\mathrm{Cu}^{2+}\) ions are consumed, so \(\mathrm{K}^{+}\) migrates towards the copper half-cell.
The tempting mistake is to put copper first because its beaker appears on the left. Notation follows the electrode reactions, not the layout.
Question 2
Two platinum electrodes are used in a galvanic cell.
The left platinum electrode is immersed in an acidified solution containing \(\ce{MnO4-}\), \(\mathrm{Mn}^{2+}\), and \(\mathrm{H}^{+}\).
The right platinum electrode is immersed in a solution containing \(\mathrm{Fe}^{2+}\) and \(\mathrm{Fe}^{3+}\).
The half-cells are joined by a potassium nitrate salt bridge. All reacting species are initially at standard conditions, and water is the solvent.
A voltmeter has its red lead connected to the right-hand platinum electrode and its black lead connected to the left-hand platinum electrode. Its idealised reading is \(-0.74\ \mathrm{V}\).
The supplied standard reduction potentials are:
| Reduction reaction | \(E^\circ_{\mathrm{red}}\) |
|---|---|
| \(\ce{MnO4- + 8H+ + 5e- -> Mn^2+ + 4H2O}\) | \(+1.51\ \mathrm{V}\) |
| \(\ce{Fe^3+ + e- -> Fe^2+}\) | \(+0.77\ \mathrm{V}\) |
Determine the cell notation, write the balanced overall reaction, and predict salt-bridge ion movement. Explain why the voltmeter displays a negative value even though the cell operates spontaneously.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 2
The iron(II)/iron(III) half-cell is the anode, and the permanganate/manganese(II) half-cell is the cathode. The standard cell potential is \(+0.74\ \mathrm{V}\); the negative meter display comes from connecting the red lead to the lower-potential electrode.
The iron(III)/iron(II) reduction potential is less positive, so the iron(II) reaction operates in reverse:
\[ \ce{Fe^2+(aq) -> Fe^3+(aq) + e-} \]
At the cathode, permanganate ions are reduced in acidic solution:
\[ \ce{MnO4- + 8H+ + 5e- -> Mn^2+ + 4H2O} \]
All the dissolved reacting species within each half-cell share one aqueous phase.
The cell notation, using the compact convention and omitting state labels for readability, is:
\[ \ce{Pt | Fe^2+, Fe^3+ || MnO4-, Mn^2+, H+ | Pt} \]
Both platinum electrodes are solids; all listed ions are aqueous. Pure water, the solvent, is not separately written in this compact representation.
Notice that the notation starts and ends with platinum. Neither half-cell has a reacting metal electrode.
To balance the reaction, multiply the iron oxidation equation by five:
\[ \ce{5Fe^2+ -> 5Fe^3+ + 5e-} \]
Adding the half-equations gives:
\[ \ce{5Fe^2+ + MnO4- + 8H+ ->} \]
\[ \ce{5Fe^3+ + Mn^2+ + 4H2O} \]
The standard potential is:
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=1.51-0.77\\ &=+0.74\ \mathrm{V} \end{aligned} \]
At the iron anode, each \(\mathrm{Fe}^{2+}\) becomes \(\mathrm{Fe}^{3+}\), increasing the positive charge of that dissolved species. Nitrate ions migrate towards this half-cell.
At the permanganate cathode, the reduction consumes positive hydrogen ions and electrons while producing \(\mathrm{Mn}^{2+}\). Potassium ions migrate towards this half-cell to help maintain charge balance.
The voltmeter reads \(-0.74\ \mathrm{V}\) because its red lead touches the negative anode while its black lead touches the positive cathode.
Swapping the leads would produce approximately \(+0.74\ \mathrm{V}\) without changing the chemistry.
The main trap is treating the negative meter display as a negative standard cell potential. The meter sign depends on lead orientation; the positive \(E^\circ_{\mathrm{cell}}\) describes the spontaneous reaction in the notation we’ve written.
Question 3
A galvanic-cell diagram shows a copper strip in \(\mathrm{Cu}^{2+}\) solution on the left.
The right-hand beaker contains a platinum electrode in contact with an acidic solution and hydrogen gas. Hydrogen gas is continuously bubbled over the platinum surface, and some bubbles escape into the surrounding gas space.
The half-cells are connected by a potassium nitrate salt bridge. Conditions are initially standard at \(25^\circ\mathrm{C}\), including hydrogen gas at \(100\ \mathrm{kPa}\).
The standard reduction potentials are:
- \(\ce{Cu^2+ + 2e- -> Cu}\): \(+0.34\ \mathrm{V}\)
- \(\ce{2H+ + 2e- -> H2}\): \(0.00\ \mathrm{V}\)
A student argues that, because hydrogen bubbles are visible at the platinum electrode, hydrogen gas must be forming there by reduction.
Assess this claim. Write the correct cell notation and overall reaction, calculate the standard potential, and predict what happens to hydrogen-ion concentration near the platinum electrode if the solution is not replenished or buffered.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 3
The student’s claim is incorrect. Hydrogen is oxidised at the platinum anode, even though hydrogen bubbles are visible. The correct notation is \(\ce{Pt | H2 | H+ || Cu^2+ | Cu}\), and the standard cell potential is \(+0.34\ \mathrm{V}\).
Start by comparing the standard reduction potentials.
Copper has the more positive reduction potential, so copper(II) ions are reduced:
\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]
The hydrogen electrode operates in the opposite direction to its listed reduction equation:
\[ \ce{H2(g) -> 2H+(aq) + 2e-} \]
The complete notation is:
\[ \ce{Pt(s) | H2(g) | H+(aq) || Cu^2+(aq) | Cu(s)} \]
The platinum is needed because hydrogen gas and hydrogen ions cannot themselves act as the solid conducting terminal.
There are two phase boundaries in the hydrogen half-cell: platinum in contact with hydrogen gas, and hydrogen gas in contact with the aqueous electrolyte.
Adding the half-equations gives:
\[ \ce{H2(g) + Cu^2+(aq) -> 2H+(aq) + Cu(s)} \]
Calculate the standard potential:
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=0.34-0.00\\ &=+0.34\ \mathrm{V} \end{aligned} \]
The visible bubbles don’t prove hydrogen is being produced. Hydrogen is supplied from outside the apparatus to maintain gas contact with the electrode.
Some gas can pass across the electrode and escape without reacting. The net electrode reaction still consumes hydrogen.
Because hydrogen oxidation produces \(\mathrm{H}^{+}\), the hydrogen-ion concentration near the platinum electrode tends to increase during operation if the solution is not replenished, buffered, or otherwise controlled.
The pH would consequently tend to decrease. As the concentrations change, the cell may no longer remain under its original standard conditions.
This is why you should distinguish what an apparatus visibly supplies from what the electrode reaction actually consumes or produces.
Question 4
A galvanic cell contains the following half-cells at \(25^\circ\mathrm{C}\):
Left beaker: A silver electrode immersed in \(0.010\ \mathrm{mol\ L^{-1}}\) \(\mathrm{Ag}^{+}\) solution.
Right beaker: A platinum electrode immersed in a solution containing \(0.50\ \mathrm{mol\ L^{-1}}\) \(\mathrm{Fe}^{3+}\) and \(0.050\ \mathrm{mol\ L^{-1}}\) \(\mathrm{Fe}^{2+}\).
A potassium nitrate salt bridge connects the solutions.
The red voltmeter lead connects to platinum, and the black lead connects to silver. An illustrative high-resistance measurement gives approximately \(+0.15\ \mathrm{V}\).
The standard reduction potentials are:
- \(\ce{Ag+ + e- -> Ag}\): \(+0.80\ \mathrm{V}\)
- \(\ce{Fe^3+ + e- -> Fe^2+}\): \(+0.77\ \mathrm{V}\)
Assume the indicated voltage reflects the cell’s open-circuit polarity, with negligible liquid-junction effects and no significant complex formation or competing reactions.
Write the notation for the actual spontaneous direction, identify the electrode reactions, and calculate the standard cell potential for the reaction you’ve written.
Explain why your standard potential has a different sign from the actual measured cell potential.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 4
Silver is the anode and the platinum/iron-ion electrode is the cathode under the stated non-standard conditions. The standard potential for that reaction direction is \(-0.03\ \mathrm{V}\), even though the actual cell operates spontaneously with an observed potential of approximately \(+0.15\ \mathrm{V}\).
The meter’s positive reading, with the red lead connected to platinum, identifies platinum as the higher-potential electrode in this operating cell.
Silver is therefore oxidised:
\[ \ce{Ag(s) -> Ag+(aq) + e-} \]
Iron(III) ions are reduced at the platinum surface:
\[ \ce{Fe^3+(aq) + e- -> Fe^2+(aq)} \]
The cell notation is:
\[ \ce{Ag(s) | Ag+(aq) || Fe^3+(aq), Fe^2+(aq) | Pt(s)} \]
The ion concentrations remain those stated in the question; writing this condensed notation does not imply standard concentrations.
The overall reaction is:
\[ \ce{Ag(s) + Fe^3+(aq) -> Ag+(aq) + Fe^2+(aq)} \]
For this reaction direction, the standard cell potential is:
\[ \begin{aligned} E^\circ_{\mathrm{cell}} &=E^\circ_{\mathrm{Fe^{3+}/Fe^{2+}}} -E^\circ_{\mathrm{Ag^+/Ag}}\\ &=0.77-0.80\\ &=-0.03\ \mathrm{V} \end{aligned} \]
The negative result means this reaction is not favoured in the forward direction under standard conditions.
But these are not standard conditions.
The silver-ion concentration is very low, which favours the production of more silver ions through oxidation. Meanwhile, the iron solution contains much more \(\mathrm{Fe}^{3+}\) than \(\mathrm{Fe}^{2+}\), favouring reduction of iron(III).
These concentration effects can shift the actual electrode potentials sufficiently to reverse the direction favoured under standard conditions.
The observed \(E_{\mathrm{cell}}\approx+0.15\ \mathrm{V}\) is consistent with the stated reaction direction under these non-standard conditions.
The tempting route is to rank the two standard reduction potentials, select silver as the cathode, and ignore the measured polarity.
That would be appropriate for a prediction under standard conditions. It is not appropriate when the experimental conditions are different and the actual polarity is given.
The key distinction is between \(E^\circ_{\mathrm{cell}}\), which refers to standard conditions, and \(E_{\mathrm{cell}}\), which refers to the actual cell.
Question 5
Two separate galvanic cells are connected in series.
Cell A contains:
- A zinc electrode in \(\mathrm{Zn}^{2+}\) solution.
- A copper electrode in \(\mathrm{Cu}^{2+}\) solution.
- A potassium nitrate salt bridge connecting its two half-cells.
Cell B contains:
- A second copper electrode in a separate \(\mathrm{Cu}^{2+}\) solution.
- A silver electrode in \(\mathrm{Ag}^{+}\) solution.
- Its own potassium nitrate salt bridge connecting these two half-cells.
A metal wire directly connects the copper electrode of Cell A to the copper electrode of Cell B.
The remaining zinc and silver electrodes are connected through a switch and a small electrical load.
All four solutions initially have standard concentrations at \(25^\circ\mathrm{C}\).
The standard reduction potentials are:
| Half-cell | \(E^\circ_{\mathrm{red}}\) |
|---|---|
| \(\ce{Zn^2+/Zn}\) | \(-0.76\ \mathrm{V}\) |
| \(\ce{Cu^2+/Cu}\) | \(+0.34\ \mathrm{V}\) |
| \(\ce{Ag+/Ag}\) | \(+0.80\ \mathrm{V}\) |
When the switch is closed, assume both cells operate as intended, with no competing reactions, and that only a small amount of reaction occurs so the concentrations stay near their initial values.
Determine:
a) The correct cell notation for Cell A and Cell B, separately.
b) The ideal standard potential between the free zinc and silver terminals, before substantial current is drawn.
c) What happens to the mass of each copper electrode as current flows, and the direction of electron flow in the two connecting wires.
d) The overall reaction for the two-cell system.
e) What happens to sustained current if the salt bridge in Cell B is removed while all metal wires remain connected.
A student argues that because copper appears in both cells, its reactions must cancel, so neither copper electrode can change mass. Assess this reasoning.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Solution 5
The two cells assist each other, producing an ideal combined standard potential of \(+1.56\ \mathrm{V}\), with silver positive relative to zinc. Copper plates onto the electrode in Cell A but dissolves from the electrode in Cell B. Removing either salt bridge prevents sustained current through the complete series circuit.
The apparent contradiction about copper disappears once we distinguish the two physically separate half-cells.
Part a: Write the notation of each cell.
For Cell A, copper has the higher standard reduction potential.
Zinc is oxidised, and copper(II) ions are reduced.
Therefore:
\[ \ce{Zn(s) | Zn^2+(aq) || Cu^2+(aq) | Cu(s)} \]
For Cell B, silver has the higher standard reduction potential.
Copper is oxidised, and silver ions are reduced.
Therefore:
\[ \ce{Cu(s) | Cu^2+(aq) || Ag+(aq) | Ag(s)} \]
The important result is that copper is the cathode material in Cell A but the anode material in Cell B.
There is no rule saying a particular metal must always be an anode or always be a cathode. Its role depends on the other half-cell and the conditions.
Part b: Calculate the combined standard potential.
For Cell A:
\[ \begin{aligned} E^\circ_A &=0.34-(-0.76)\\ &=+1.10\ \mathrm{V} \end{aligned} \]
For Cell B:
\[ \begin{aligned} E^\circ_B &=0.80-0.34\\ &=+0.46\ \mathrm{V} \end{aligned} \]
Because the cells are connected in series with their potentials assisting each other:
\[ \begin{aligned} E^\circ_{\mathrm{total}} &=E^\circ_A+E^\circ_B\\ &=1.10+0.46\\ &=+1.56\ \mathrm{V} \end{aligned} \]
This is the ideal standard potential across the free zinc and silver terminals.
Once current is drawn through the load, the measured terminal voltage need not equal exactly \(1.56\ \mathrm{V}\), because real cells have internal resistance and other operating effects.
Part c: Track the copper electrodes and electrons.
In Cell A, copper(II) ions are reduced:
\[ \ce{Cu^2+(aq) + 2e- -> Cu(s)} \]
Copper metal deposits onto its electrode, so that electrode gains mass.
In Cell B, copper metal is oxidised:
\[ \ce{Cu(s) -> Cu^2+(aq) + 2e-} \]
Its copper electrode loses mass.
These reactions are connected electrically, but they take place in different solutions.
Through the outer wire containing the electrical load, electrons move from the zinc electrode of Cell A towards the silver electrode of Cell B.
Through the direct wire joining the two copper electrodes, electrons move from the copper anode of Cell B towards the copper cathode of Cell A.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Part d: Find the overall reaction.
Cell A has the overall reaction:
\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]
Cell B has:
\[ \ce{Cu(s) + 2Ag+(aq) -> Cu^2+(aq) + 2Ag(s)} \]
If we add the reactions and consider only the total chemical inventory across both cells, the equal quantities of copper species cancel.
The resulting overall net equation is:
\[ \ce{Zn(s) + 2Ag+(aq) -> Zn^2+(aq) + 2Ag(s)} \]
This equation is correct as a net chemical balance for the combined system.
But here’s the hidden constraint: the copper species that cancel algebraically are located in different compartments.
Copper(II) ions are consumed in Cell A and produced in Cell B. Copper metal is deposited in A and dissolved in B.
The total copper inventory is unchanged, but its distribution among the four reservoirs of solid and dissolved material changes.
Algebraic cancellation tells us that there is no net creation or destruction of copper across the combined system. It does not mean copper is chemically inactive at each electrode.
Part e: Remove one salt bridge.
If Cell B’s salt bridge is removed, sustained current through the series circuit stops, apart from possible brief transients.
The external metal wires are still connected, but the ionic circuit of Cell B is broken.
Without its salt bridge, Cell B cannot maintain the charge balance required for continued electron transfer. Because the two cells share one series current path, Cell A cannot continue driving current through the load independently of the interrupted Cell B.
The lamp would stop being powered by the combined series circuit.
A high-resistance voltmeter might still detect a potential difference across parts of the disconnected arrangement. That would not demonstrate sustained current flow.
The student’s copper-cancellation argument is therefore wrong for two separate reasons.
First, cancelling species in an overall chemical equation doesn’t remove the individual electrode reactions occurring in different places.
Second, a favourable overall reaction doesn’t remove the need for a complete ionic path through every operating cell.
This is the deeper reason cell notation matters when studying batteries made from several electrochemical cells. A combined reaction and an overall voltage can hide important differences between the actual half-cells, including where metal is deposited, where ions accumulate, and which connection must remain intact for current to flow.