Learn why electrons flow from the anode to the cathode in a galvanic cell, and how this differs from ion movement through the salt bridge. Includes electrode reactions, voltmeter conventions, worked examples, and HSC Chemistry practice questions.

Connect a zinc strip and a copper strip to a voltmeter, with each metal immersed in its own solution. The zinc strip gradually loses mass, copper builds up on the other electrode, and the voltmeter reads a positive voltage when its red lead is connected to copper.

Which way are the electrons moving?

From zinc to copper through the external wire. Electrons leave the zinc electrode, where oxidation occurs, and travel to the copper electrode, where reduction occurs. In a galvanic cell, this means electrons flow from the anode to the cathode.

There is another part of the circuit to understand, though. Electrons travel through the connecting wire, while ions move through the salt bridge. These are two different movements, and confusing them is one of the easiest ways to lose marks in an electrochemistry question.

Before going further, predict something: if you disconnect the wire but leave the salt bridge in place, will the cell continue producing a steady current?

No. The salt bridge allows ions to move, but it cannot replace the external pathway that carries electrons between the electrodes. A working galvanic cell needs both.

01How the Daniell cell helped establish the direction of electron flow

The direction of electron movement is not something we can watch directly. Instead, we infer it from electrode reactions, changes in the electrodes, and electrical measurements.

The development of the Daniell cell provides a useful way to understand how these ideas fit together.

The problem with earlier electrical cells

Alessandro Volta’s early battery, the voltaic pile, demonstrated that chemical arrangements involving different metals and an electrolyte could produce a sustained electrical current.

However, the original design had a practical problem. Hydrogen gas accumulated at the cathode during operation. This gas formation contributed to polarisation, causing the cell’s voltage to decrease.

In 1836, John Frederic Daniell introduced an improved cell. Rather than producing hydrogen at the copper-side cathode, the design used copper(II) ions from copper sulfate solution. These ions accepted electrons and deposited as solid copper.

A porous earthenware pot separated the two electrolytes, reducing their direct mixing while still allowing ionic conduction.

This produced a more reliable source of electrical energy. The historical development is described in the Electrochemical Society’s account of Volta’s pile and the Daniell cell.

What did the apparatus look like?

In the classic Daniell arrangement:

  1. A zinc rod sits inside a porous earthenware container containing the zinc-side electrolyte.
  2. This container sits inside a larger vessel containing copper sulfate solution.
  3. A copper electrode, often the outer copper vessel itself, contacts the copper sulfate solution.
  4. An external wire connects the zinc and copper electrodes.
  5. A measuring instrument connected to the terminals detects the electrical potential difference or current.

The porous pot separates the two solutions without completely preventing ions from moving between them.

Cross-section of a historical Daniell cell. A zinc rod stands in zinc sulfate solution inside a porous earthenware pot, surrounded by copper sulfate solution in an outer copper vessel. External wires connect the zinc rod and copper vessel to a voltmeter.
The porous pot separates zinc sulfate from the surrounding copper sulfate while allowing ionic contact; the zinc rod and copper vessel connect through a voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Now consider what should happen when the external circuit is completed.

At the zinc electrode, zinc atoms lose electrons and enter the solution as zinc ions. Those electrons remain in the conducting metal and can travel through the external wire.

At the copper electrode, copper(II) ions accept electrons and become solid copper. The copper deposits onto the electrode.

The expected observations are:

  • The zinc electrode loses mass.
  • The copper electrode gains mass.
  • The concentration of zinc ions increases.
  • The concentration of copper(II) ions decreases.

These observations support the proposed electron-transfer process. The electrons themselves are not directly visible; their direction is inferred from the electrode reactions and electrical measurements.

The key improvement was not simply separating two solutions. Daniell’s design also provided a different cathode reaction, avoiding the hydrogen-gas problem that affected earlier cells.

02The two paths through a working galvanic cell

Modern classroom experiments often use two separate beakers rather than the original porous-pot arrangement.

A typical zinc-copper cell contains:

  • A zinc strip in zinc sulfate solution.
  • A copper strip in copper sulfate solution.
  • A potassium nitrate salt bridge connecting the solutions.
  • An external wire connecting the metal electrodes.
  • A high-resistance voltmeter measuring the potential difference.
A modern Daniell galvanic cell with separate zinc sulfate and copper sulfate beakers, joined by a potassium nitrate U-shaped salt bridge. Zinc is the negative anode and dissolves into Zn2+ ions; copper is the positive cathode where Cu2+ ions deposit. A high-resistance voltmeter connects the electrodes through the external circuit. Electron arrows point from zinc to copper, while nitrate ions move towards the zinc compartment and potassium ions move towards the copper compartment.
Electrons move from zinc to copper through the external circuit, while salt-bridge ions maintain charge balance as zinc dissolves and copper deposits.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The important idea is that the cell has two different pathways for charge movement.

1. Electron movement through the external wire

At the zinc electrode, oxidation occurs:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

Each zinc atom that becomes a zinc ion releases two electrons.

These electrons travel through the external wire towards the copper electrode.

At the copper electrode, reduction occurs:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

Copper(II) ions accept the electrons and form solid copper.

Adding the half-equations gives the overall reaction:

\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]

Notice that the electrons produced by zinc oxidation are exactly the electrons consumed by copper reduction.

This gives us the first important rule:

In a galvanic cell, electrons flow through the external circuit from the anode to the cathode.

2. Ion movement through the salt bridge

Now consider the salt bridge.

Why can’t the electrons simply travel through the wire while the solutions remain unchanged?

Because the electrode reactions would quickly create an imbalance of electrical charge in the two solutions.

At the zinc electrode, zinc atoms become positively charged zinc ions:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

This increases the positive ionic charge in the zinc compartment.

At the copper electrode, copper(II) ions are removed from solution:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

This removes positive charge from the copper compartment, leaving the solution relatively more negative.

If these imbalances continue to develop, they oppose further electron transfer.

The salt bridge prevents this from happening by allowing ions to migrate between the compartments.

For a potassium nitrate salt bridge:

  • \(\mathrm{NO_{3}}^{-}\) ions move towards the zinc anode.
  • \(\mathrm{K}^{+}\) ions move towards the copper cathode.

Why these directions?

The zinc compartment gains positive charge as \(\mathrm{Zn}^{2+}\) forms. Negative nitrate ions help compensate.

The copper compartment loses positive charge as \(\mathrm{Cu}^{2+}\) is reduced. Positive potassium ions help compensate.

The movements can be summarised as follows.

Part of cellWhat movesDirection or change
External wireElectronsZinc to copper
Zinc electrodeZinc atomsBecome \(\mathrm{Zn}^{2+}\) ions
Copper electrodeCopper(II) ionsBecome solid copper
Salt bridge\(\mathrm{NO_{3}}^{-}\)Towards zinc anode
Salt bridge\(\mathrm{K}^{+}\)Towards copper cathode

The distinction is essential: electrons move through the external wire, while ions move through the electrolyte and salt bridge.

The salt bridge is not an electron pathway.

If the salt bridge is blocked, the cell may initially produce a brief electrical response, but sustained current quickly stops because the ionic pathway can no longer maintain charge balance.

03Anode, cathode, and electrode polarity

You now know that electrons travel from zinc to copper in a Daniell cell.

Let’s connect that movement to the formal terminology used in HSC Chemistry.

Two definitions are particularly important:

  • Anode: the electrode where oxidation occurs.
  • Cathode: the electrode where reduction occurs.

These definitions apply to both galvanic and electrolytic cells.

For a galvanic cell, the electrode signs are:

ElectrodeReactionPolarity
AnodeOxidationNegative (-)
CathodeReductionPositive (+)

Therefore, in a zinc-copper galvanic cell:

  • Zinc is the negative anode.
  • Copper is the positive cathode.
  • Electrons travel from zinc to copper.

A useful way to remember the reactions is:

An Ox, Red Cat.

Anode = oxidation. Cathode = reduction.

However, don’t confuse these reaction definitions with electrode polarity. The signs can change in a different type of electrochemical cell.

Electron flow versus conventional current

There is another distinction worth knowing.

Electrons are negatively charged. Conventional current, however, is defined as the direction in which positive charge would flow.

Consequently, conventional current travels in the opposite direction to electron movement through a metal wire.

For the zinc-copper galvanic cell:

  • Electron flow: zinc to copper.
  • Conventional current: copper to zinc.
Two matching zinc–copper galvanic cell diagrams. Electrons travel from the negative zinc anode to the positive copper cathode; conventional current travels in the opposite direction. Both show the salt bridge and external wire connections.
In a zinc–copper galvanic cell, electrons move from zinc to copper, while conventional current travels in the opposite direction.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Don’t interchange these directions in an explanation. If a question asks for electron flow, give the direction of electrons, not conventional current.

What changes in an electrolytic cell?

Here is a useful contrasting case.

Suppose an external power supply is connected to two electrodes immersed in an electrolyte. The power supply forces a chemical reaction that would not proceed spontaneously in that direction.

This is an electrolytic cell.

The electrode reaction definitions remain unchanged:

  • Oxidation still occurs at the anode.
  • Reduction still occurs at the cathode.

However, the electrode signs are reversed.

ElectrodeGalvanic cellElectrolytic cell
AnodeNegativePositive
CathodePositiveNegative
Anode reactionOxidationOxidation
Cathode reactionReductionReduction

Why does this happen?

In an electrolytic cell, the external power supply pulls electrons away from the anode and supplies electrons to the cathode.

The anode is therefore connected to the positive terminal of the power supply, while the cathode is connected to its negative terminal.

Side-by-side schematic of a zinc–copper galvanic cell and an electrolytic copper sulfate cell. Electrons flow from the negative zinc anode to the positive copper cathode in the galvanic cell. In the electrolytic cell, a DC supply connects graphite electrode A to negative and B to positive, producing copper deposits at A and oxygen bubbles at B.
Electrons flow from zinc to copper in the galvanic cell, while a DC supply drives copper plating at A and oxygen formation at B.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

The important lesson is that anode and cathode are named according to the reactions occurring at the electrodes, not their electrical signs.

For a galvanic cell, remember:

  • Anode = negative.
  • Cathode = positive.
  • Electrons travel from anode to cathode.

04Standard potential versus actual voltmeter readings

So far, we’ve used the zinc-copper cell as though its voltage were always exactly \(1.10\ \mathrm{V}\).

That’s not necessarily what you will measure in a laboratory.

To understand why, we need to distinguish standard cell potential from actual cell potential.

What does the standard potential tell you?

Standard reduction potentials are reference values measured relative to the standard hydrogen electrode.

For HSC calculations, standard conditions are generally taken as:

  • Aqueous species at \(1.0\ \mathrm{mol\,L^{-1}}\).
  • Gases at \(100\ \mathrm{kPa}\).
  • Temperature of \(25^\circ\mathrm{C}\), or \(298\ \mathrm{K}\).
  • Pure solids and liquids in their standard states.

For the zinc-copper cell, the relevant standard reduction potentials are:

Reduction half-equationStandard reduction potential
\(\ce{Cu^2+(aq) + 2e^- -> Cu(s)}\)\(+0.34\ \mathrm{V}\)
\(\ce{Zn^2+(aq) + 2e^- -> Zn(s)}\)\(-0.76\ \mathrm{V}\)

Copper has the more positive reduction potential, so copper(II) ions are reduced at the cathode.

Zinc is oxidised at the anode.

The standard cell potential is:

\[ E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} \]

\[ E^\circ_{\text{cell}} = (+0.34)-(-0.76) \]

\[ \boxed{E^\circ_{\text{cell}}=+1.10\ \mathrm{V}} \]

The positive result indicates that the reaction proceeds spontaneously in the direction written under standard conditions.

The more positive reduction potential identifies the cathode, which then allows you to determine electron flow.

For a fuller explanation of comparing half-cell potentials, see Reduction Potentials of Galvanic Half-Cells: HSC Chemistry.

Why might your voltmeter show a different value?

A real cell does not necessarily operate under standard conditions.

Its solution concentrations, temperature, electrode surfaces, and electrical connections may differ from the ideal reference conditions.

For example, a zinc-copper cell might have a standard cell potential of \(+1.10\ \mathrm{V}\), but a practical experiment might produce a reading of \(+1.06\ \mathrm{V}\).

That does not automatically mean the experiment has failed.

The two values describe different things:

QuantityMeaning
\(E^\circ_{\text{cell}}\)Standard cell potential under standard conditions
\(E_{\text{cell}}\)Actual cell potential under the conditions of the operating cell
Voltmeter displaySigned reading determined by the actual potential difference and the order of the meter leads

There is another subtlety.

A digital voltmeter displays the potential of its red terminal relative to its black terminal:

\[ V_{\text{display}}=V_{\text{red}}-V_{\text{black}} \]

If the red lead is connected to the copper cathode and the black lead to the zinc anode, the reading is positive.

If you swap the leads, the reading becomes negative.

The chemistry has not changed. Only the measurement convention has changed.

A negative voltmeter display does not automatically mean that the galvanic reaction is non-spontaneous.

For a more detailed explanation of concentration, temperature, electrode surfaces, and measurement effects, see Why a Galvanic Cell’s Measured Voltage Differs from E°.

Course context: As at 7 November 2026, the Chemistry Stage 6 Syllabus (2017) remains in use, with the Chemistry 11-12 Syllabus (2025) scheduled to begin implementation in 2028. This explanation covers galvanic-cell principles without claiming that every detail is a prescribed requirement of the new syllabus. See the NSW syllabus implementation information.

05Worked examples

Worked example: Calculate the changes at each electrode

A zinc-copper galvanic cell operates until \(0.00400\ \mathrm{mol}\) of zinc has been oxidised.

Assume that the only electrode reactions are zinc oxidation and copper(II) reduction.

Calculate:

  • The amount of electrons transferred.
  • The amount of copper deposited.
  • The mass change of each electrode.

Use \(M(\ce{Zn})=65.38\ \mathrm{g\,mol^{-1}}\) and \(M(\ce{Cu})=63.55\ \mathrm{g\,mol^{-1}}\).

Step 1

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

Each mole of zinc produces two moles of electrons.

Therefore:

\[ n(e^-)=2\times0.00400 \]

\[ n(e^-)=0.00800\ \mathrm{mol} \]

Step 2

The copper reduction reaction is:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

Two moles of electrons are required to deposit one mole of copper.

Therefore:

\[ n(\ce{Cu})=\frac{0.00800}{2} \]

\[ n(\ce{Cu})=0.00400\ \mathrm{mol} \]

Step 3

Using \(m=nM\), where \(m\) is mass, \(n\) is amount in moles, and \(M\) is molar mass:

\[ m(\ce{Zn})=0.00400\times65.38 \]

\[ m(\ce{Zn})=0.26152\ \mathrm{g} \]

The zinc electrode loses approximately \(0.262\ \mathrm{g}\).

Step 4

\[ m(\ce{Cu})=0.00400\times63.55 \]

\[ m(\ce{Cu})=0.2542\ \mathrm{g} \]

The copper electrode gains approximately \(0.254\ \mathrm{g}\).

Final interpretation: Zinc loses mass because zinc atoms enter the solution as ions. Copper gains mass because copper(II) ions are reduced and deposited as solid copper.

The electrons travel from the zinc electrode to the copper electrode through the external wire.

Notice that the two electrodes do not change by equal masses. They react in equal mole amounts, but zinc and copper have different molar masses.

Worked example: A negative voltmeter reading in a galvanic cell

A zinc-copper galvanic cell is assembled at \(25^\circ\mathrm{C}\).

The zinc half-cell contains \(1.0\ \mathrm{mol\,L^{-1}}\) zinc ions, while the copper half-cell contains \(0.10\ \mathrm{mol\,L^{-1}}\) copper(II) ions.

A high-resistance digital voltmeter is connected with:

  • Red lead on the zinc electrode.
  • Black lead on the copper electrode.

The meter displays \(-1.07\ \mathrm{V}\).

Determine:

  1. Which electrode is positive.
  2. The direction of electron flow.
  3. What the voltmeter displays if the leads are swapped.
  4. Why the reading does not contradict the standard cell potential of \(+1.10\ \mathrm{V}\).

Step 1

The voltmeter displays:

\[ V_{\text{red}}-V_{\text{black}} \]

The red lead is connected to zinc, and the black lead is connected to copper.

The negative reading means:

\[ V_{\ce{Zn}}<V_{\ce{Cu}} \]

Therefore, copper is the positive electrode, and zinc is the negative electrode.

Step 2

In this galvanic cell:

  • Zinc is the negative anode.
  • Copper is the positive cathode.

Electrons travel from the negative zinc electrode towards the positive copper electrode.

The electron direction is therefore:

\[ \boxed{\ce{Zn -> Cu}} \]

The negative voltmeter reading does not reverse this direction.

Step 3

Swapping the red and black leads reverses the order of the potential difference.

The new reading is:

\[ \boxed{+1.07\ \mathrm{V}} \]

The cell’s chemistry remains unchanged.

Step 4

The standard cell potential is \(+1.10\ \mathrm{V}\), calculated using standard conditions.

However, the copper(II) concentration in this example is only \(0.10\ \mathrm{mol\,L^{-1}}\), rather than the standard \(1.0\ \mathrm{mol\,L^{-1}}\).

The cell is therefore operating under non-standard conditions. Its actual potential can differ from the standard value.

The two numbers are not contradictory:

  • \(+1.10\ \mathrm{V}\) is the standard cell potential.
  • \(-1.07\ \mathrm{V}\) is the actual voltmeter display with the red lead connected to zinc.

The negative sign comes from the lead arrangement.

Zinc-copper galvanic cell with two beakers containing 1.0 mol L⁻¹ ZnSO₄ and 0.10 mol L⁻¹ CuSO₄, joined by a KNO₃ salt bridge. The voltmeter's red lead connects to zinc, its black lead to copper, and its display reads −1.07 V.
With the red lead connected to zinc and the black lead connected to copper, the high-resistance voltmeter displays a negative potential difference.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Zinc–copper galvanic cell showing zinc as the negative anode and copper as the positive cathode. Electrons flow from zinc to copper through the external leads. Nitrate ions migrate towards zinc and potassium ions towards copper through a potassium nitrate salt bridge. The red voltmeter lead connects to zinc, the black lead to copper, and the display reads −1.07 V.
Electrons move from zinc to copper; with the red lead on zinc and black lead on copper, the voltmeter reads −1.07 V.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

06Questions and solutions

Question 1

A galvanic cell is constructed using a magnesium electrode and a copper electrode.

The magnesium electrode is immersed in \(1.0\ \mathrm{mol\,L^{-1}}\) magnesium nitrate solution. The copper electrode is immersed in \(1.0\ \mathrm{mol\,L^{-1}}\) copper sulfate solution.

The half-cells are connected using a potassium nitrate salt bridge.

The standard reduction potentials are:

\[ E^\circ(\ce{Mg^2+/Mg})=-2.37\ \mathrm{V} \]

\[ E^\circ(\ce{Cu^2+/Cu})=+0.34\ \mathrm{V} \]

Determine:

a) Which electrode is the anode and which is the cathode.

b) The direction of electron flow.

c) The oxidation and reduction half-equations.

d) The standard cell potential.

e) The directions of potassium and nitrate ion movement through the salt bridge.

Two glass beakers contain magnesium nitrate and copper sulfate solutions with magnesium and copper electrode strips. A potassium nitrate salt bridge connects the solutions, while an external wire connects both electrodes through a voltmeter.
The two half-cells are connected ionically by a potassium nitrate salt bridge and electrically by an external wire containing a voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 1

Electrons flow from magnesium to copper. Magnesium is the negative anode, and copper is the positive cathode.

a) Identify the electrodes.

Copper has the more positive reduction potential:

\[ +0.34\ \mathrm{V}>-2.37\ \mathrm{V} \]

Therefore, copper undergoes reduction at the cathode.

Magnesium undergoes oxidation at the anode.

b) Determine electron flow.

Electrons travel from the anode to the cathode.

Therefore:

\[ \boxed{\ce{Mg -> Cu}} \]

c) Write the half-equations.

Magnesium oxidation:

\[ \ce{Mg(s) -> Mg^2+(aq) + 2e^-} \]

Copper reduction:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

Adding the half-equations gives:

\[ \ce{Mg(s) + Cu^2+(aq) -> Mg^2+(aq) + Cu(s)} \]

d) Calculate the standard cell potential.

\[ \begin{aligned} E^\circ_{\text{cell}} &=E^\circ_{\text{cathode}} -E^\circ_{\text{anode}}\\ &=(+0.34)-(-2.37)\\ &=+2.71\ \mathrm{V} \end{aligned} \]

The positive standard cell potential confirms that the reaction is spontaneous under standard conditions.

e) Determine ion movement.

Magnesium oxidation produces additional positive ions in the magnesium compartment. Nitrate ions therefore migrate towards the magnesium anode.

Copper(II) ions are consumed in the copper compartment. Potassium ions migrate towards the copper cathode to help maintain electrical neutrality.

The key is that salt bridge ions move to maintain charge balance, not to transport electrons.

Question 2

An iron-silver galvanic cell is operating under non-standard conditions.

A digital voltmeter is connected with its red lead on the iron electrode and its black lead on the silver electrode.

The meter displays:

\[ -1.18\ \mathrm{V} \]

The standard reduction potentials are:

\[ E^\circ(\ce{Fe^2+/Fe})=-0.44\ \mathrm{V} \]

\[ E^\circ(\ce{Ag+/Ag})=+0.80\ \mathrm{V} \]

Answer the following:

a) Identify the positive and negative electrodes.

b) Determine the direction of electron flow.

c) Explain why the voltmeter displays a negative reading even though the cell is operating spontaneously.

d) Calculate the standard cell potential.

e) State the direction of conventional current through the external circuit when a load is connected.

f) Predict the voltmeter reading after the leads are swapped, assuming the cell conditions remain unchanged.

An iron electrode in Fe²⁺ solution and a silver electrode in Ag⁺ solution are connected by a U-shaped salt bridge and a digital voltmeter. The red lead connects to iron, the black lead to silver, and the display reads -1.18 V.
The voltmeter compares the two half-cells with its red lead on iron and its black lead on silver.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 2

Electrons flow from iron to silver. Iron is the negative anode, while silver is the positive cathode.

a) Identify the electrode polarities.

The voltmeter measures the potential of the red terminal relative to the black terminal.

Because the reading is negative, the iron electrode is at a lower potential than the silver electrode.

Therefore:

  • Iron is negative.
  • Silver is positive.

b) Determine electron flow.

Electrons travel from the negative anode to the positive cathode.

\[ \boxed{\ce{Fe -> Ag}} \]

Iron atoms are oxidised, while silver ions are reduced.

c) Explain the negative reading.

The negative reading does not indicate that the reaction is non-spontaneous.

It occurs because the red lead is connected to the negative electrode.

The meter is measuring:

\[ V_{\ce{Fe}}-V_{\ce{Ag}} \]

Since the iron electrode has a lower potential, this difference is negative.

d) Calculate the standard cell potential.

Silver has the more positive reduction potential, so it is the cathode.

\[ \begin{aligned} E^\circ_{\text{cell}} &=E^\circ_{\text{cathode}} -E^\circ_{\text{anode}}\\ &=(+0.80)-(-0.44)\\ &=+1.24\ \mathrm{V} \end{aligned} \]

The standard cell potential is \(+1.24\ \mathrm{V}\).

The actual reading has a magnitude of \(1.18\ \mathrm{V}\), rather than \(1.24\ \mathrm{V}\), because the cell is operating under non-standard conditions.

e) Determine conventional current direction.

Conventional current travels opposite to electron flow through the external metal circuit.

Therefore, it travels:

\[ \boxed{\ce{Ag -> Fe}} \]

f) Predict the new reading.

Swapping the voltmeter leads reverses the sign.

The new reading is:

\[ \boxed{+1.18\ \mathrm{V}} \]

The reaction direction and electrode polarities remain unchanged.

The important distinction is between the actual electrode polarity and the sign displayed by a particular meter connection.

Question 3

A galvanic cell contains two half-cells:

  • A zinc electrode immersed in zinc sulfate solution.
  • A platinum electrode immersed in a solution containing both \(\mathrm{Fe}^{3+}\) and \(\mathrm{Fe}^{2+}\) ions.

The solutions are connected using a potassium nitrate salt bridge.

The standard reduction potentials are:

\[ E^\circ(\ce{Zn^2+/Zn})=-0.76\ \mathrm{V} \]

\[ E^\circ(\ce{Fe^3+/Fe^2+})=+0.77\ \mathrm{V} \]

Assume standard conditions and that the platinum electrode is chemically inert.

Determine:

a) The anode and cathode.

b) The oxidation and reduction half-equations.

c) The overall balanced reaction.

d) The standard cell potential.

e) The direction of electron flow and salt bridge ion movement.

f) Whether the platinum electrode gains mass as the cell operates. Justify your answer.

A two-compartment galvanic cell showing a zinc strip immersed in ZnSO₄ solution and a platinum electrode immersed in a solution containing Fe³⁺ and Fe²⁺ ions. The compartments are connected by a KNO₃ salt bridge, while an external wire connects both electrodes through a voltmeter.
The two electrolyte compartments are connected by a KNO₃ salt bridge and an external electrical circuit containing a voltmeter.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 3

Electrons flow from zinc to platinum. Zinc is the anode, and platinum is the cathode. The platinum electrode does not gain mass.

a) Identify the electrodes.

The iron(III)/iron(II) reduction potential is more positive than the zinc reduction potential.

Therefore, iron(III) ions are reduced at the platinum electrode.

Platinum is the cathode, while zinc is the anode.

b) Write the half-equations.

At the zinc anode:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

At the platinum cathode:

\[ \ce{Fe^3+(aq) + e^- -> Fe^2+(aq)} \]

Balance the electrons by multiplying the reduction half-equation by two:

\[ \ce{2Fe^3+(aq) + 2e^- -> 2Fe^2+(aq)} \]

c) Write the overall reaction.

Adding the balanced half-equations gives:

\[ \ce{Zn(s) + 2Fe^3+(aq) -> Zn^2+(aq) + 2Fe^2+(aq)} \]

d) Calculate the standard cell potential.

\[ \begin{aligned} E^\circ_{\text{cell}} &=E^\circ_{\text{cathode}} -E^\circ_{\text{anode}}\\ &=(+0.77)-(-0.76)\\ &=+1.53\ \mathrm{V} \end{aligned} \]

The positive value indicates that the reaction is spontaneous under standard conditions.

e) Determine electron and ion movement.

Electrons move through the external wire from zinc to platinum.

The zinc anode produces additional positive ions, so nitrate ions migrate towards the zinc compartment.

At the platinum cathode, iron(III) ions become iron(II) ions. The positive ionic charge decreases, so potassium ions migrate towards the platinum compartment.

f) Determine whether platinum gains mass.

No. Platinum does not gain mass because it is an inert conducting electrode.

The reduction reaction converts dissolved iron(III) ions into dissolved iron(II) ions. It does not produce solid iron.

This is an important distinction: a cathode is where reduction occurs, but reduction does not always produce a metal deposit.

Question 4

An electrolytic cell contains aqueous copper sulfate solution and two graphite electrodes connected to a direct-current power supply.

The negative terminal of the power supply is connected to electrode A, while the positive terminal is connected to electrode B.

During electrolysis, copper deposits on electrode A, and oxygen gas forms at electrode B.

A student makes the following statement:

“The anode must be negative because it is where electrons are released. Therefore, electrode B cannot be the anode.”

Evaluate this statement.

In your response:

a) Identify the anode and cathode.

b) State the polarity of each electrode.

c) Write the electrode half-equations.

d) Explain the direction of electron movement through the external circuit.

e) Explain why the student has confused the definitions of anode and cathode.

An electrolytic cell containing aqueous copper sulfate, with two graphite electrodes immersed in a glass beaker. Electrode A connects to the negative terminal of a DC power supply and has a visible copper coating. Electrode B connects to the positive terminal and has oxygen bubbles forming around it.
The DC supply drives electrolysis in aqueous copper sulfate: copper coats electrode A while oxygen bubbles appear at electrode B.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 4

The student’s statement is incorrect. Electrode A is the negative cathode, and electrode B is the positive anode.

a) Identify the electrodes.

Copper deposits on A, meaning copper(II) ions gain electrons.

Reduction therefore occurs at A, making it the cathode.

Oxygen forms at B through oxidation, making B the anode.

b) Identify electrode polarities.

The power supply determines the electrode signs:

  • A is negative because it is connected to the negative terminal.
  • B is positive because it is connected to the positive terminal.

c) Write the half-equations.

At the cathode:

\[ \ce{Cu^2+(aq) + 2e^- -> Cu(s)} \]

At the anode, assuming water is oxidised:

\[ \ce{2H2O(l) -> O2(g) + 4H+(aq) + 4e^-} \]

Reduction occurs at A, and oxidation occurs at B.

d) Explain electron movement.

The power supply delivers electrons from its negative terminal to electrode A.

Electrons released at electrode B travel through the external wire into the positive terminal of the power supply.

The power supply uses electrical energy to drive the non-spontaneous chemical reaction.

Electrons do not travel through the aqueous solution between the electrodes. Ions carry charge through the electrolyte.

e) Explain the misconception.

The student has assumed that anode and cathode are permanent labels for negative and positive electrodes.

They are not.

The anode is always where oxidation occurs, and the cathode is always where reduction occurs.

Only the electrode polarities change between galvanic and electrolytic cells.

Question 5

A zinc-copper galvanic cell is constructed using zinc sulfate and copper sulfate solutions, with a potassium nitrate salt bridge.

The cell operates through an external load.

Two voltmeter measurements are taken under the same conditions:

MeasurementRed leadBlack leadReading
AZincCopper\(-1.06\ \mathrm{V}\)
BCopperZinc\(+1.06\ \mathrm{V}\)

After the cell has operated for some time, the following electrode mass changes are recorded:

ElectrodeMass change
Zinc\(-0.327\ \mathrm{g}\)
Copper\(+0.318\ \mathrm{g}\)

The molar masses are:

\[ M(\ce{Zn})=65.38\ \mathrm{g\,mol^{-1}} \]

\[ M(\ce{Cu})=63.55\ \mathrm{g\,mol^{-1}} \]

Assume:

  • Only zinc oxidation and copper(II) reduction occur.
  • No electrode material is lost through flaking or mechanical damage.
  • The potassium nitrate salt bridge supplies the ions required to maintain charge balance.
  • No competing reactions occur.

Answer the following:

a) Determine the direction of electron flow and identify the anode and cathode.

b) Explain why the two voltmeter readings have opposite signs, even though they were measured from the same cell.

c) Calculate the amount, in moles, of zinc oxidised and copper deposited. Explain whether the two mass changes are consistent with the proposed cell reaction.

d) Calculate the amount, in moles, of electrons transferred.

e) Determine the direction and amount of potassium and nitrate ions that must migrate through the salt bridge to maintain charge balance.

f) A student suggests replacing the salt bridge with an impermeable barrier that prevents all ion movement but still keeps the two solutions separate. Predict what happens to the sustained current and explain why.

Two beakers contain ZnSO₄ and CuSO₄ solutions, joined by a KNO₃ U-shaped salt bridge. Zinc and copper electrodes connect through an external load and voltmeter. Labels show both electrode mass changes, with two inset diagrams illustrating the swapped red and black voltmeter leads and their readings.
The cell drawing links the two sulfate solutions, nitrate salt bridge, external load and voltmeter to the two lead-polarity readings.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.

Solution 5

Electrons flow from zinc to copper. Zinc is the negative anode, and copper is the positive cathode. The two voltmeter readings describe the same potential difference with opposite lead arrangements.

This question requires you to connect three independent pieces of evidence: voltmeter polarity, electrode mass changes, and ionic charge balance.

a) Determine electron flow and electrode identities.

Zinc loses mass, while copper gains mass.

These observations indicate that zinc atoms are becoming dissolved zinc ions, while copper(II) ions are being converted into solid copper.

Therefore:

  • Zinc undergoes oxidation and is the anode.
  • Copper undergoes reduction and is the cathode.

Electrons travel:

\[ \boxed{\ce{Zn -> Cu}} \]

The zinc electrode is negative, and the copper electrode is positive.

b) Explain the opposite voltmeter readings.

A digital voltmeter measures:

\[ V_{\text{display}}=V_{\text{red}}-V_{\text{black}} \]

For measurement A, the red lead is connected to zinc, which is the negative electrode.

Therefore:

\[ V_{\text{red}}<V_{\text{black}} \]

The display is negative:

\[ -1.06\ \mathrm{V} \]

For measurement B, the leads are reversed.

The red lead is now connected to copper, the positive electrode, so the display is:

\[ +1.06\ \mathrm{V} \]

Both readings are correct.

The tempting mistake is to interpret the negative sign as evidence that electrons are flowing in the opposite direction. However, the sign describes the order in which the voltmeter compares its terminals. It does not independently establish the direction of electron movement.

c) Calculate the amounts of zinc and copper involved.

First, calculate the amount of zinc oxidised:

\[ n=\frac{m}{M} \]

\[ \begin{aligned} n(\ce{Zn}) &=\frac{0.327}{65.38}\\ &=0.00500\ \mathrm{mol} \end{aligned} \]

Now calculate the amount of copper deposited:

\[ \begin{aligned} n(\ce{Cu}) &=\frac{0.318}{63.55}\\ &=0.00500\ \mathrm{mol} \end{aligned} \]

Both electrodes have changed by approximately \(0.00500\ \mathrm{mol}\).

This is consistent with the overall reaction:

\[ \ce{Zn(s) + Cu^2+(aq) -> Zn^2+(aq) + Cu(s)} \]

The reaction consumes one mole of zinc for every mole of copper produced.

The small differences in the calculated values disappear when the results are rounded to three significant figures.

d) Calculate the amount of electrons transferred.

The oxidation half-equation is:

\[ \ce{Zn(s) -> Zn^2+(aq) + 2e^-} \]

Every mole of zinc oxidised produces two moles of electrons.

Therefore:

\[ \begin{aligned} n(e^-)&=2\times0.00500\\ &=0.0100\ \mathrm{mol} \end{aligned} \]

The cell transfers \(0.0100\ \mathrm{mol}\) of electrons through the external circuit.

e) Determine the direction and amount of salt bridge ion movement.

This is where charge balance becomes important.

At the zinc anode, \(0.00500\ \mathrm{mol}\) of zinc ions are produced.

Each zinc ion has a \(2+\) charge.

Therefore, the positive charge added to the zinc compartment is equivalent to:

\[ 0.00500\times2=0.0100\ \mathrm{mol} \]

of positive charge equivalents.

Nitrate ions must enter this compartment to compensate.

Since nitrate has a single negative charge:

\[ n(\mathrm{NO_{3}}^{-})=0.0100\ \mathrm{mol} \]

Nitrate ions move towards the zinc anode.

At the copper cathode, \(0.00500\ \mathrm{mol}\) of copper(II) ions are consumed.

This removes the equivalent of:

\[ 0.00500\times2=0.0100\ \mathrm{mol} \]

of positive charge equivalents.

Potassium ions enter the copper compartment to compensate.

Since potassium has a single positive charge:

\[ n(\mathrm{K}^{+})=0.0100\ \mathrm{mol} \]

Potassium ions move towards the copper cathode.

The final result is:

IonDirectionAmount transferred
\(\mathrm{NO_{3}}^{-}\)Towards zinc anode\(0.0100\ \mathrm{mol}\)
\(\mathrm{K}^{+}\)Towards copper cathode\(0.0100\ \mathrm{mol}\)

The important point is that the salt bridge maintains electrical neutrality. It does not transport electrons.

f) Predict what happens if ion movement is blocked.

The cell cannot sustain its current.

The external wire would still provide a pathway for electrons, but the solutions could no longer maintain electrical neutrality.

As zinc oxidation produces additional \(\mathrm{Zn}^{2+}\), positive charge accumulates in the zinc compartment.

As copper(II) ions are consumed, negative charge becomes relatively excessive in the copper compartment.

This charge separation opposes further electron transfer.

The cell may initially produce a brief electrical response, but sustained current rapidly stops.

The tempting prediction is that the external wire alone should be enough to complete the circuit. It isn’t. A galvanic cell requires both an electronic pathway through the wire and an ionic pathway through the electrolyte and salt bridge.

A completed zinc-copper galvanic cell showing electrons flowing through the external wire from the zinc anode to the copper cathode. Nitrate ions migrate through the potassium nitrate salt bridge towards zinc, while potassium ions migrate towards copper. Zinc loses 0.327 g and copper gains 0.318 g.
Electrons travel through the external wire from zinc to copper, while nitrate and potassium ions migrate through the salt bridge to maintain charge balance.

Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.


The direction of electron flow is the starting point for understanding any galvanic cell. Once you can identify the anode, cathode, external electron pathway, and internal ion movement, the next step is to use standard reduction potentials to predict which half-cell will accept electrons and calculate the cell’s potential.

Keep the distinction between standard potential and actual measured voltage in mind: one is a reference prediction, while the other describes the cell under its actual operating conditions.