Motor Torque-Speed Curves: Comparing Motor Behaviour
Interpret torque-speed curves, relate torque to power and compare motor characteristics with worked examples in this physics extension guide.
A motor can spin faster while delivering less torque. Imagine an inverter-controlled motor that produces 24 N m at 2400 rpm but only 14.4 N m at 4000 rpm. Has the motor become weaker? Not necessarily. It may have reached its maximum output power, forcing its available torque to decrease as speed increases.
Now consider a different motor connected directly to a fixed-frequency AC supply. Its speed might barely change as the load increases, right up until it suddenly loses synchronism.
These behaviours seem contradictory. They aren’t. They come from differences in how motors produce torque and how their electrical supplies control the rotating magnetic field.
A torque-speed curve makes these differences easier to understand.
Scope note: This article builds on the Year 12 Electromagnetism content of the 2025 NSW Physics syllabus. The comparison of induction, synchronous, and electronically controlled permanent-magnet motor torque-speed envelopes goes beyond the required syllabus content. It is an extension resource, not an additional HSC assessment requirement. The 2025 syllabus is scheduled for implementation from 2027, with its first HSC examination in 2028, according to NESA’s implementation information.
01What does a torque-speed curve actually show?
Torque measures the turning effect produced by a force. For a motor, it tells us how strongly the shaft can turn against a load.
A torque-speed curve describes how much torque a motor can produce at different rotational speeds under specified operating conditions.
The two axes are:
- Horizontal axis: rotational speed, usually measured in revolutions per minute (rpm).
- Vertical axis: torque, measured in newton metres (N m).
A motor’s torque-speed curve is not a graph of how its speed changes with time. It describes the torque available at different operating speeds.
This distinction matters because a motor does not necessarily operate at its maximum available torque. Its actual operating point depends on the load connected to its shaft.
For example:
- If the motor produces more torque than the load requires, it accelerates.
- If the motor produces less torque than the load requires, it slows down.
- If the motor torque equals the load torque, it can operate at a steady speed.
There is another relationship worth remembering:
\[ P_{\mathrm{mech}}=\tau\omega \]
Here:
- \(P_{\mathrm{mech}}\) is mechanical output power in watts (W).
- \(\tau\) is torque in newton metres (N m).
- \(\omega\) is angular velocity in radians per second (rad s\(^{-1}\)).
If rotational speed is given in rpm, convert it using:
\[ \omega=\frac{2\pi n}{60} \]
where \(n\) is rotational speed in rpm.
This equation explains an important feature of motor curves: if output power is constant, increasing rotational speed requires decreasing torque.
A motor can therefore spin faster while becoming less capable of overcoming a large turning load.
02The electromagnetic foundation: how a brushless DC motor produces torque
Before comparing the curves, it helps to revisit the electromagnetic process inside a brushless DC motor.
The 2025 syllabus provides the starting point through electromagnetic induction, Lenz’s law, and the operation of brushless DC motors.
Start with changing magnetic flux
Recall Faraday’s law:
\[ \varepsilon=-N\frac{\Delta\Phi}{\Delta t} \]
Here:
- \(\varepsilon\) is the induced electromotive force (emf), measured in volts.
- \(N\) is the number of turns in the coil.
- \(\Delta\Phi\) is the change in magnetic flux, measured in webers.
- \(\Delta t\) is the time over which the flux changes.
Magnetic flux describes the magnetic field passing through a coil’s area.
For a uniform magnetic field:
\[ \Phi=BA\cos\theta \]
where \(B\) is magnetic field strength, \(A\) is the coil’s area, and \(\theta\) is the angle between the magnetic field and the normal to the coil.
When a magnet moves relative to a coil, the magnetic flux through that coil can change. This produces an induced emf.
In a motor, this induced voltage is often called back emf because it opposes the applied voltage.
How this works in a brushless DC motor
A typical brushless DC (BLDC) motor has two main parts:
- Stator: the stationary component containing several electromagnetic windings.
- Rotor: the rotating component containing permanent magnets.
The stator windings form the motor’s armature. Unlike a conventional brushed DC motor, the armature does not need to rotate.
The motor receives electrical energy from a DC source, but an electronic controller switches the current through the stator windings in a carefully timed sequence.
For example:
- Current flows through two selected stator phases.
- These currents produce magnetic fields in the stator.
- The stator’s magnetic field interacts with the permanent magnets on the rotor.
- Magnetic attraction and repulsion produce a turning effect.
- The controller switches the current to different phases as the rotor moves.
The result is a rotating magnetic field that the permanent-magnet rotor follows.
The torque-producing interaction is the motor effect: current-carrying conductors experience magnetic forces, producing a net turning effect on the motor.
For the underlying relationship between current and motor torque, see Why Increasing Motor Current Increases Torque: HSC Physics.
Where electromagnetic induction enters
There is an important extra detail.
In many sensorless BLDC motors, the controller uses electromagnetic induction to estimate the rotor’s position.
At a particular instant, one stator phase can be left unpowered while the other phases produce the rotating magnetic field.
As the permanent-magnet rotor moves past the unpowered winding, its magnetic field produces a changing magnetic flux through that winding.
Faraday’s law tells us that an emf is induced.
The controller monitors this back emf, often using its zero-crossing point, to estimate the rotor’s position. It can then determine when to energise the next phases.
This is called electronic commutation.
The sequence allows the motor to maintain a correctly timed rotating magnetic field and produce continuous torque.
One distinction is worth getting right: the induced back emf is not itself the mechanical force turning the rotor. It provides electrical feedback that helps the controller time the torque-producing currents. The torque comes from the interaction between the stator currents and the permanent-magnet rotor field.
Some motors use Hall-effect sensors or encoders to determine rotor position instead. The back-emf sensing method is particularly useful in sensorless designs.
03Three different torque-speed characteristics
Now we can compare three motor arrangements.
The important point is that we must specify the electrical supply before interpreting a torque-speed curve.
For this comparison, assume:
- The induction motor is connected directly to a fixed-voltage, fixed-frequency, three-phase AC supply.
- The conventional synchronous motor is connected to a fixed-frequency AC supply and is already operating in synchronism.
- The permanent-magnet motor is supplied by a fixed DC bus through an inverter that controls its phase currents and output frequency.
These are deliberately different supply arrangements. Changing the supply or adding a variable-speed drive can change the torque-speed characteristic substantially.
There is also a naming detail: a permanent-magnet synchronous motor is technically a type of synchronous motor. In the comparison below, the conventional synchronous motor means a line-fed, wound-field machine, while the permanent-magnet motor means an electronically controlled BLDC or PMSM drive.
1. Induction motor: torque depends on slip
An induction motor produces torque through electromagnetic induction.
Its stator contains windings supplied with alternating current. In a three-phase motor, these currents produce a rotating magnetic field.
The rotating field passes the rotor conductors and induces currents within them.
These induced currents produce their own magnetic field, which interacts with the stator’s rotating field to generate torque.
The important feature is that the rotor must rotate at a different speed from the stator’s magnetic field.
This difference is called slip.
Synchronous speed
The speed of the rotating magnetic field is called synchronous speed.
It depends on the supply frequency and the number of magnetic poles:
\[ n_s=\frac{120f}{p} \]
where:
- \(n_s\) is synchronous speed in rpm.
- \(f\) is the supply frequency in hertz (Hz).
- \(p\) is the total number of motor poles.
For example, a four-pole motor connected to a 50 Hz supply has:
\[ n_s=\frac{120(50)}{4} =1500\text{ rpm} \]
The rotor does not normally reach 1500 rpm while operating as a motor.
If it did, there would be no relative motion between the rotor conductors and the rotating magnetic field. The magnetic flux through the rotor conductors would no longer change because of their relative motion.
Consequently, there would be no induced rotor emf, no induced rotor current, and no electromagnetic torque in the idealised model.
Calculating slip
Slip measures the difference between synchronous speed and rotor speed relative to synchronous speed.
\[ s=\frac{n_s-n_r}{n_s} \]
where:
- \(s\) is slip, expressed as a decimal or percentage.
- \(n_s\) is synchronous speed.
- \(n_r\) is actual rotor speed.
If a motor has a synchronous speed of 1500 rpm but rotates at 1440 rpm:
\[ s=\frac{1500-1440}{1500} =0.04 \]
Its slip is 4%.
That small speed difference is essential. It allows electromagnetic induction to produce the rotor currents needed for torque.
For a more detailed explanation of the rotor mechanism, see How a Squirrel-Cage Rotor Produces Torque in an Induction Motor.
What does the induction motor’s curve look like?
When voltage and frequency are held constant, a typical induction motor has a torque-speed curve with several important features:
- At zero speed, it produces a finite starting torque.
- As it accelerates, torque may initially decrease before rising again.
- It reaches a maximum torque called breakdown torque, pull-out torque, or maximum torque.
- As rotor speed approaches synchronous speed, torque falls towards zero.
The exact shape around starting speed depends on the motor’s design.
The important operating region is usually close to synchronous speed, where the motor operates with relatively small slip.
Suppose the load suddenly increases.
What happens?
The rotor initially slows down. This increases slip, producing greater induced rotor emf and current. The resulting electromagnetic torque increases, helping the motor overcome the additional load.
The motor settles at a slightly lower speed if the increased load remains within its available torque capacity.
However, if the load demands more than the breakdown torque, the motor cannot maintain a stable operating point. It slows down and may stall.
This characteristic is described in ABB’s Technical Guide No. 7: Dimensioning of a Drive System.
An induction motor connected to a variable-frequency drive behaves differently. Changing the supply frequency changes the rotating field speed, allowing the motor to operate across a wider speed range. The fixed-frequency curve described here should not be treated as a universal characteristic of every induction motor.
2. Conventional synchronous motor: speed stays fixed
A synchronous motor behaves differently from an induction motor.
Its stator produces a rotating magnetic field, just as an induction motor does.
However, its rotor has its own magnetic field, usually produced by a DC-excited field winding in the conventional wound-field design.
The rotor magnetic field locks into the rotating stator field.
Once synchronised, the rotor rotates at exactly the same speed as the stator’s magnetic field.
Therefore:
\[ n_r=n_s \]
This remains true as the load changes, provided the motor stays within its pull-out torque limit.
What happens when the load increases?
Imagine a synchronous motor driving a conveyor belt.
The conveyor suddenly becomes heavier.
You might predict that the rotor slows down slightly, as it does in an induction motor.
But that is not what happens during normal synchronous operation.
Instead, the rotor falls further behind the rotating stator field in angular position while maintaining the same average rotational speed.
This angular separation is called the torque angle, represented by \(\delta\).
The larger torque angle allows the motor to produce more torque.
For an ideal cylindrical-rotor synchronous motor with fixed excitation, a simplified torque relationship is:
\[ \tau=\tau_{\max}\sin\delta \]
Here:
- \(\tau\) is developed electromagnetic torque.
- \(\tau_{\max}\) is the ideal maximum or pull-out torque.
- \(\delta\) is the electrical angle between the rotor magnetic field and the stator’s rotating magnetic field.
The torque reaches its maximum at a torque angle of approximately \(90^\circ\) in this simplified model.
Real synchronous motors can have more complicated torque-angle relationships, particularly when their rotors have salient poles.
If the load increases further, the torque angle continues to increase.
Eventually, the motor reaches its pull-out torque.
Beyond this point, the rotor cannot maintain synchronism with the stator field. The motor loses synchronism and may decelerate or stall.
The critical difference is that the motor does not normally respond to increasing load by gradually reducing its steady-state speed.
It maintains synchronous speed until it can no longer maintain the magnetic coupling.
WEG’s technical guide, The ABCs of Synchronous Motors, discusses this relationship between load angle and pull-out torque.
3. Electronically controlled permanent-magnet motor: constant torque, then falling torque
Now consider a BLDC motor or permanent-magnet synchronous motor (PMSM) connected to an inverter.
The permanent-magnet rotor follows a rotating magnetic field produced by the stator windings.
The inverter controls the electrical frequency and current supplied to those windings.
This gives the controller much greater control over the motor’s speed and torque.
The motor’s idealised maximum torque-speed envelope has two main operating regions.
Region 1: Constant torque
At low rotational speeds, the motor’s maximum torque is primarily limited by the maximum current that the stator windings and inverter can safely handle.
For a simplified surface-mounted permanent-magnet motor:
\[ \tau\approx k_T I_T \]
where:
- \(\tau\) is motor torque in N m.
- \(k_T\) is the motor’s torque constant in N m/A.
- \(I_T\) is the torque-producing current in amperes (A).
Increasing the torque-producing current increases torque.
However, the current cannot increase indefinitely. Excessive current produces resistive heating in the windings and places additional demands on the inverter.
The maximum continuous current therefore limits the maximum continuous torque.
As long as the motor remains below its base speed, the inverter can generally maintain this maximum torque.
The resulting torque-speed curve is approximately horizontal.
This is called the constant-torque region.
Region 2: Constant power
Now consider what happens as the motor spins faster.
Remember that the permanent magnets are moving relative to the stator windings.
This produces an increasing rate of magnetic flux change, so the induced back emf increases with rotational speed.
For an idealised motor with constant magnetic flux:
\[ E_b\propto\omega \]
where \(E_b\) is the magnitude of the induced back emf.
Eventually, the required motor voltage reaches the maximum voltage that the inverter can supply.
This is the base speed, represented by \(n_b\).
The inverter cannot simply keep increasing its output voltage to maintain the same current and torque at higher speeds.
Instead, it can use a technique called field weakening.
Field weakening involves adjusting the stator current to oppose some of the magnetic flux produced by the permanent magnets. This reduces the effective flux and allows the motor to operate at higher speeds without exceeding the inverter’s voltage limit.
However, there is a trade-off.
Some of the available current is now being used to weaken the magnetic field rather than produce torque. The available torque therefore decreases.
Over a useful operating range, the motor can maintain approximately constant mechanical power.
Since:
\[ P_{\mathrm{mech}}=\tau\omega \]
constant power means:
\[ \tau=\frac{P_{\max}}{\omega} \]
where \(P_{\max}\) is the maximum mechanical output power in this region.
Therefore, torque decreases approximately inversely with rotational speed.
If the motor doubles its speed while maintaining constant power, its maximum available torque halves.
The idealised torque envelope can be written as:
\[ \tau_{\max}(n)\approx \begin{cases} \tau_b, & n\leq n_b\\[4pt] \tau_b\dfrac{n_b}{n}, & n>n_b \end{cases} \]
Here:
- \(\tau_{\max}(n)\) is the maximum available torque at speed \(n\).
- \(\tau_b\) is the maximum continuous torque at base speed.
- \(n_b\) is base speed.
- \(n\) is the current rotational speed, expressed in the same units as \(n_b\).
This is an idealised model, not a universal rule for every permanent-magnet motor.
The actual high-speed torque capability depends on the motor’s magnetic design, winding inductance, current limit, inverter voltage, and thermal constraints. Some motors have a relatively narrow field-weakening range, while others are designed for much wider constant-power operation.
MIT’s Electric Machines course notes on permanent-magnet brushless motors and a 2023 review of permanent-magnet synchronous motor drives provide further technical detail on these operating limits.
04Comparing the three torque-speed curves
We can now put the three motor arrangements together.
| Feature | Induction motor | Line-fed synchronous motor | Inverter-fed PM motor |
|---|---|---|---|
| Supply | Fixed-frequency AC | Fixed-frequency AC | Fixed DC bus with inverter |
| Speed control | Depends on slip and supply frequency | Locked to supply frequency | Controlled by inverter frequency |
| Low-speed torque | Finite starting torque; rises towards breakdown torque | Depends on load angle and pull-out limit | Approximately constant maximum torque |
| Response to increasing load | Speed falls slightly and slip increases | Speed remains constant until pull-out | Controller increases torque until a current or voltage limit is reached |
| High-speed behaviour | Torque approaches zero at synchronous speed | Remains at synchronous speed while synchronised | Torque decreases above base speed |
| Main operating limit | Breakdown torque and thermal limits | Pull-out torque | Current and voltage limits, thermal and mechanical limits |
There are three important observations.
First, induction motors need slip to produce torque. Their rotor must move at a different speed from the stator’s rotating field.
Second, synchronous motors do not normally slow down as their load increases. Their rotor remains locked to the rotating magnetic field until the pull-out limit is exceeded.
Third, electronically controlled permanent-magnet motors can operate over a wide speed range. Their inverter allows precise control of the rotating magnetic field, but maximum torque eventually decreases as voltage and current constraints become important.
The curves are therefore not simply properties of the motor’s physical construction. They also depend on how the motor is supplied and controlled.
05Worked examples
Worked example: Calculate the slip of an induction motor
A four-pole induction motor is connected directly to a 50 Hz, three-phase supply. Its rotor rotates at 1440 rpm under load.
Calculate:
- The synchronous speed.
- The slip as a percentage.
Step 1
Use:
\[ n_s=\frac{120f}{p} \]
Substitute the supply frequency and number of poles:
\[ n_s=\frac{120(50)}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
Step 2
The actual rotor speed is 1440 rpm.
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1500-1440}{1500} \]
\[ s=0.04 \]
Convert to a percentage:
\[ s=0.04\times100 \]
\[ \boxed{s=4\%} \]
Interpretation: The rotor rotates 60 rpm slower than the stator’s rotating magnetic field. This difference in speed allows the rotor conductors to experience changing magnetic flux, inducing the currents needed to produce torque.
Worked example: Calculate torque above base speed
An inverter-controlled permanent-magnet motor can supply a maximum continuous torque of 24 N m up to its base speed of 2400 rpm.
Above base speed, assume it operates in an ideal constant-power region.
Calculate:
- Its maximum mechanical output power at base speed.
- Its maximum torque at 4000 rpm.
- The speed at which its maximum torque falls to 12 N m.
Assume field weakening is available throughout the stated speed range, with no additional thermal or mechanical limitation.
Step 1
\[ \omega_b=\frac{2\pi n_b}{60} \]
\[ \omega_b=\frac{2\pi(2400)}{60} \]
\[ \omega_b=251.3\text{ rad s}^{-1} \]
Step 2
\[ P_{\max}=\tau_b\omega_b \]
\[ P_{\max}=24(251.3) \]
\[ \boxed{P_{\max}=6031\text{ W}\approx6.03\text{ kW}} \]
This is the maximum ideal mechanical output power in the constant-power region.
Step 3
First, convert 4000 rpm into angular velocity:
\[ \omega=\frac{2\pi(4000)}{60} \]
\[ \omega=418.9\text{ rad s}^{-1} \]
Using the constant-power relationship:
\[ \tau=\frac{P_{\max}}{\omega} \]
\[ \tau=\frac{6031}{418.9} \]
\[ \boxed{\tau\approx14.4\text{ N m}} \]
The available torque has decreased because the motor is rotating faster while maintaining approximately the same output power.
Step 4
Since power remains constant:
\[ P_{\max}=\tau\omega \]
Rearrange:
\[ \omega=\frac{6031}{12} \]
\[ \omega=502.6\text{ rad s}^{-1} \]
Convert back into rpm:
\[ n=\frac{60\omega}{2\pi} \]
\[ n=\frac{60(502.6)}{2\pi} \]
\[ \boxed{n=4800\text{ rpm}} \]
Interpretation: At twice its base speed, the motor produces half its base-speed torque in this ideal constant-power model. The motor has not lost its ability to convert energy. Its available turning force has decreased because the same output power is being delivered at a higher rotational speed.
06Common misconceptions
Before attempting the questions, make sure you can distinguish these four ideas.
| Tempting assumption | What actually happens |
|---|---|
| Every motor slows down when its load increases. | An induction motor slows slightly, a synchronous motor maintains its speed until pull-out, and an inverter-controlled PM motor adjusts its operation within its limits. |
| An induction motor produces maximum torque at synchronous speed. | Its ideal electromagnetic torque is zero at synchronous speed because there is no slip. |
| Back emf is what physically pushes a BLDC rotor around. | Back emf opposes the applied voltage and can provide rotor-position information. Torque comes from magnetic-field interaction with the current-carrying windings. |
| Constant power means constant torque. | Constant power requires torque to decrease as rotational speed increases. |
One particularly important distinction is the difference between induction and synchronous operation.
An induction motor needs relative motion between its rotor and the rotating magnetic field to induce rotor currents.
A permanent-magnet synchronous motor does not need induced rotor currents to produce torque. Its rotor already has a magnetic field supplied by permanent magnets.
That difference becomes especially important when examining motors operating at synchronous speed.
07Questions and solutions
Question 1
A six-pole induction motor is connected directly to a 50 Hz AC supply. Its rotor rotates at 970 rpm.
Calculate:
- The synchronous speed.
- The slip as a percentage.
Solution 1
The synchronous speed is 1000 rpm, and the slip is 3%.
The synchronous speed is:
\[ n_s=\frac{120f}{p} \]
Substituting:
\[ n_s=\frac{120(50)}{6} \]
\[ \boxed{n_s=1000\text{ rpm}} \]
Now calculate slip:
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1000-970}{1000} \]
\[ s=0.03 \]
Therefore:
\[ \boxed{s=3\%} \]
The rotor rotates 30 rpm slower than the rotating magnetic field. This relative motion allows an emf and current to be induced in the rotor, producing electromagnetic torque.
Question 2
A four-pole induction motor is connected directly to a 50 Hz, three-phase supply.
Its steady-state torque-speed characteristic has the following values:
| Rotor speed | Motor torque |
|---|---|
| 1470 rpm | 40 N m |
| 1450 rpm | 60 N m |
| Maximum breakdown torque | 80 N m |
Initially, the motor drives a conveyor requiring 40 N m of torque.
The conveyor load then increases to 60 N m.
(a) Calculate the slip at both 1470 rpm and 1450 rpm.
(b) Calculate the rotor current frequency at both operating speeds, given that rotor current frequency is:
\[ f_r=sf \]
where \(f_r\) is rotor current frequency and \(f\) is supply frequency.
(c) Explain why the motor settles at 1450 rpm after the load increases.
(d) Predict what happens if the conveyor load increases further to 85 N m.
Assume both specified operating points lie on the normal high-speed motoring branch of the characteristic.
Solution 2
The motor settles at 1450 rpm after the load increases to 60 N m, provided the motor remains below its breakdown torque. If the load rises to 85 N m, the motor cannot maintain a stable operating point and will stall.
Step 1: Calculate synchronous speed.
\[ n_s=\frac{120f}{p} \]
\[ n_s=\frac{120(50)}{4} \]
\[ n_s=1500\text{ rpm} \]
Step 2: Calculate slip at 1470 rpm.
\[ s_1=\frac{1500-1470}{1500} \]
\[ s_1=0.02 \]
Therefore:
\[ \boxed{s_1=2\%} \]
Step 3: Calculate slip at 1450 rpm.
\[ s_2=\frac{1500-1450}{1500} \]
\[ s_2=0.0333 \]
Therefore:
\[ \boxed{s_2=3.33\%} \]
Step 4: Calculate the rotor current frequencies.
Initially:
\[ f_{r1}=s_1f \]
\[ f_{r1}=0.02(50) \]
\[ \boxed{f_{r1}=1.0\text{ Hz}} \]
After the load increases:
\[ f_{r2}=s_2f \]
\[ f_{r2}=0.0333(50) \]
\[ \boxed{f_{r2}\approx1.67\text{ Hz}} \]
The rotor current frequency increases because the relative speed between the rotor and the rotating magnetic field has increased.
Step 5: Explain the new operating point.
Initially, the motor produces 40 N m at 1470 rpm, balancing the conveyor’s load torque.
When the load increases to 60 N m, the load torque temporarily exceeds the motor torque.
The rotor slows down.
This increases slip, which increases the induced rotor current and electromagnetic torque.
At 1450 rpm, the motor produces 60 N m, matching the new load.
The motor can therefore settle at this lower speed.
The operating point is stable on the high-speed branch: if the rotor slows slightly further, motor torque increases above the load torque, helping it accelerate back. If it speeds up slightly, motor torque decreases below the load torque, helping it slow down.
Step 6: Consider the 85 N m load.
The maximum available breakdown torque is 80 N m.
Since:
\[ 85>80 \]
the motor cannot produce enough electromagnetic torque to balance the load.
There is no steady motoring operating point on the stated characteristic that can support this load.
The rotor continues slowing down and may stall.
The key idea is that increased slip helps an induction motor overcome an increased load, but only up to its maximum available torque.
Question 3
A six-pole, wound-field synchronous motor is connected to a fixed 50 Hz AC supply.
Its idealised maximum pull-out torque is 180 N m.
Assume its torque-angle relationship is:
\[ \tau=\tau_{\max}\sin\delta \]
Initially, the motor drives a load requiring 90 N m.
The load then increases to 150 N m.
(a) Calculate the synchronous speed.
(b) Calculate the torque angle at the initial operating point.
(c) Calculate the new torque angle after the load increases.
(d) Explain what happens if the load torque increases to 190 N m.
Assume an ideal cylindrical-rotor model with constant field excitation and neglect losses.
Solution 3
The motor operates at 1000 rpm under both the 90 N m and 150 N m loads. Its torque angle increases from 30 degrees to approximately 56.4 degrees. At 190 N m, it exceeds pull-out torque and loses synchronism.
Step 1: Calculate synchronous speed.
\[ n_s=\frac{120f}{p} \]
\[ n_s=\frac{120(50)}{6} \]
\[ \boxed{n_s=1000\text{ rpm}} \]
Step 2: Calculate the initial torque angle.
Rearrange the torque relationship:
\[ \sin\delta=\frac{\tau}{\tau_{\max}} \]
Substitute the initial load torque:
\[ \sin\delta_1=\frac{90}{180} \]
\[ \sin\delta_1=0.5 \]
Therefore:
\[ \boxed{\delta_1=30^\circ} \]
Step 3: Calculate the new torque angle.
After the load increases:
\[ \sin\delta_2=\frac{150}{180} \]
\[ \sin\delta_2=0.8333 \]
Taking the inverse sine:
\[ \boxed{\delta_2\approx56.4^\circ} \]
The rotor falls further behind the stator’s rotating magnetic field in angular position.
However, its rotational speed remains 1000 rpm because it is still synchronised.
Step 4: Consider a load torque of 190 N m.
The maximum available torque is:
\[ \tau_{\max}=180\text{ N m} \]
The new load requires:
\[ \tau_L=190\text{ N m} \]
Since:
\[ 190>180 \]
there is no possible torque angle in the idealised model that can produce the required torque.
The motor therefore loses synchronism.
The tempting prediction is that the motor will simply slow down until it produces enough torque. That describes the normal response of an induction motor, not a line-fed synchronous motor.
A synchronous motor must maintain its magnetic lock with the rotating stator field. Once the required torque exceeds its pull-out limit, that lock cannot be maintained.
Question 4
An inverter-controlled permanent-magnet motor has a maximum continuous torque of 36 N m up to its base speed of 1800 rpm.
Above base speed, assume an ideal constant-power region.
The field-weakening system can operate up to at least 3000 rpm.
The same motor is considered for two applications:
- A conveyor requiring a constant load torque of 24 N m.
- A fan requiring a load torque given by:
\[ \tau_f=36\left(\frac{n}{1800}\right)^2 \]
where \(n\) is the fan speed in rpm and \(\tau_f\) is the fan’s required torque in N m.
Calculate the maximum continuous operating speed for each application.
Ignore losses and assume the motor can deliver any torque up to its stated maximum torque envelope.
Solution 4
The conveyor can operate at a maximum continuous speed of 2700 rpm, while the fan reaches its maximum continuous operating speed at 1800 rpm.
The difference comes from how each load’s required torque changes with speed.
Step 1: Calculate the motor’s maximum continuous power at base speed.
Convert base speed into angular velocity:
\[ \omega_b=\frac{2\pi(1800)}{60} \]
\[ \omega_b=188.5\text{ rad s}^{-1} \]
Calculate power:
\[ P_{\max}=\tau_b\omega_b \]
\[ P_{\max}=36(188.5) \]
\[ \boxed{P_{\max}\approx6.79\text{ kW}} \]
Step 2: Determine the maximum torque above base speed.
In the constant-power region:
\[ \tau_{\max}=\frac{P_{\max}}{\omega} \]
Since the base-speed torque is 36 N m at 1800 rpm, we can write:
\[ \boxed{\tau_{\max}=36\frac{1800}{n}} \]
This equation gives the maximum available torque at any speed above 1800 rpm.
Step 3: Calculate the conveyor’s maximum speed.
The conveyor requires a constant torque of 24 N m.
At the maximum sustainable speed, the required torque equals the motor’s available maximum torque:
\[ 24=36\frac{1800}{n} \]
Rearrange:
\[ n=\frac{36(1800)}{24} \]
\[ \boxed{n=2700\text{ rpm}} \]
The conveyor can therefore operate up to 2700 rpm, assuming the motor’s field-weakening range extends that far.
Step 4: Calculate the fan’s maximum speed.
The fan’s required torque increases with the square of rotational speed:
\[ \tau_f=36\left(\frac{n}{1800}\right)^2 \]
At maximum continuous operating speed, the motor’s available torque equals the fan’s required torque:
\[ 36\left(\frac{1800}{n}\right) = 36\left(\frac{n}{1800}\right)^2 \]
Cancel 36:
\[ \frac{1800}{n} = \left(\frac{n}{1800}\right)^2 \]
Rearrange:
\[ \left(\frac{n}{1800}\right)^3=1 \]
Therefore:
\[ \boxed{n=1800\text{ rpm}} \]
The fan reaches the motor’s maximum continuous torque at base speed.
Above this speed, the fan requires more torque as its speed increases, while the motor’s maximum available torque decreases.
There is no higher-speed operating point within the stated model where the motor can meet the fan’s torque demand.
Interpretation: The same motor can support a higher speed when driving a constant-torque conveyor than when driving this fan.
The motor’s torque-speed envelope has not changed. The difference comes from the load’s torque-speed relationship.
This is why motor selection must consider both the motor curve and the load curve.
Question 5
Two four-pole motors are tested using external prime movers that force their shafts to rotate at exactly 1500 rpm.
The motors are:
- Motor A: A squirrel-cage induction motor connected directly to a fixed 50 Hz, three-phase AC supply.
- Motor B: An electronically controlled surface-mounted permanent-magnet synchronous motor supplied by a fixed DC bus through an inverter.
For Motor B, the inverter is set to produce a 50 Hz rotating magnetic field. Its controller can command a braking torque of 20 N m, and its DC link can accept regenerated electrical energy.
An engineer makes the following statement:
“Both motors are rotating at synchronous speed. Therefore, neither motor can produce electromagnetic torque because there is no relative motion between the rotor and the stator’s rotating magnetic field.”
Evaluate this statement.
Your answer must:
(a) Determine the slip of Motor A at 1500 rpm and explain its electromagnetic torque.
(b) Explain whether Motor B can produce the specified braking torque at the same rotational speed.
(c) Calculate the mechanical power converted by Motor B when producing this braking torque at 1500 rpm.
(d) The prime movers now increase both shaft speeds to 1530 rpm. Calculate Motor A’s slip and explain the direction of its electromagnetic torque.
(e) Determine the inverter frequency required for Motor B to remain synchronised at 1530 rpm. Explain whether it can still produce braking torque, and calculate the corresponding mechanical power converted if the braking torque remains 20 N m.
Assume ideal operation, neglect losses, and assume the inverter has sufficient current and voltage capability throughout the specified conditions.
Solution 5
The engineer’s statement is incorrect.
Motor A produces zero ideal electromagnetic torque at exactly 1500 rpm because its rotor has zero slip relative to the rotating magnetic field.
Motor B can still produce the specified braking torque at 1500 rpm because its permanent-magnet rotor interacts with the stator’s current-produced magnetic field. At 1530 rpm, Motor A operates as an induction generator, while Motor B must increase its inverter frequency to 51 Hz to remain synchronised.
The important distinction is that zero slip eliminates induction torque in an ideal induction motor, but it does not eliminate torque in a permanent-magnet synchronous motor.
Step 1: Calculate synchronous speed for Motor A.
\[ n_s=\frac{120f}{p} \]
\[ n_s=\frac{120(50)}{4} \]
\[ \boxed{n_s=1500\text{ rpm}} \]
Step 2: Calculate Motor A’s slip at 1500 rpm.
\[ s=\frac{n_s-n_r}{n_s} \]
\[ s=\frac{1500-1500}{1500} \]
\[ \boxed{s=0} \]
There is no relative motion between the rotor and the rotating magnetic field.
Consequently, there is no induced rotor emf or rotor current in the ideal induction motor model, and its electromagnetic torque is zero.
The stator can still draw magnetising current. Zero rotor torque does not mean that every electrical current in the motor disappears.
Step 3: Determine whether Motor B can produce braking torque at 1500 rpm.
Yes.
Motor B has a permanent-magnet rotor. It does not rely on induced rotor currents to produce torque.
Its inverter controls the phase currents in the stator windings. These currents produce a magnetic field that interacts with the rotor’s permanent magnetic field.
The relative angular position and current phasing determine the direction and magnitude of the torque.
The rotor can therefore remain synchronised with the stator’s rotating field while producing either motoring or braking torque.
The absence of slip does not mean the torque must be zero.
Step 4: Calculate the mechanical power converted during braking at 1500 rpm.
Convert the rotational speed into angular velocity:
\[ \omega=\frac{2\pi n}{60} \]
\[ \omega=\frac{2\pi(1500)}{60} \]
\[ \omega=157.1\text{ rad s}^{-1} \]
The magnitude of the mechanical power is:
\[ |P_{\mathrm{mech}}|=|\tau|\omega \]
\[ |P_{\mathrm{mech}}|=20(157.1) \]
\[ \boxed{|P_{\mathrm{mech}}|=3142\text{ W}} \]
\[ \boxed{|P_{\mathrm{mech}}|\approx3.14\text{ kW}} \]
Because the torque opposes rotation, mechanical energy enters the motor rather than leaving it.
The motor operates as a generator, returning approximately 3.14 kW to the DC link in the idealised model.
Step 5: Calculate Motor A’s slip at 1530 rpm.
Its supply frequency remains 50 Hz, so its synchronous speed remains 1500 rpm.
\[ s=\frac{1500-1530}{1500} \]
\[ s=-0.02 \]
Therefore:
\[ \boxed{s=-2\%} \]
The negative slip indicates that the rotor is rotating faster than the stator’s magnetic field.
The relative motion now produces induced rotor currents with the phase relationship required for generator operation.
The electromagnetic torque opposes the rotor’s rotation.
Motor A therefore converts mechanical energy from the external prime mover into electrical energy.
Step 6: Calculate the inverter frequency required by Motor B.
For Motor B to remain synchronised at 1530 rpm, its stator’s rotating magnetic field must also rotate at 1530 rpm.
Rearrange the synchronous speed equation:
\[ n_s=\frac{120f}{p} \]
\[ f=\frac{n_sp}{120} \]
Substitute:
\[ f=\frac{1530(4)}{120} \]
\[ \boxed{f=51\text{ Hz}} \]
The inverter must therefore increase its output frequency from 50 Hz to 51 Hz.
The controller can then maintain synchronism while commanding the same 20 N m braking torque, assuming its electrical limits permit.
Step 7: Calculate the mechanical power converted at 1530 rpm.
First, calculate angular velocity:
\[ \omega=\frac{2\pi(1530)}{60} \]
\[ \omega=160.2\text{ rad s}^{-1} \]
Then:
\[ |P_{\mathrm{mech}}|=20(160.2) \]
\[ \boxed{|P_{\mathrm{mech}}|\approx3204\text{ W}} \]
\[ \boxed{|P_{\mathrm{mech}}|\approx3.20\text{ kW}} \]
The motor converts approximately 3.20 kW of mechanical input into electrical output.
If the inverter had remained at 50 Hz, its rotating magnetic field would still have a synchronous speed of 1500 rpm. The rotor at 1530 rpm could not remain locked to that field in steady synchronous operation.
This is the crucial distinction between the two machines.
For an induction motor, slip is necessary to induce rotor currents and produce electromagnetic torque.
For a permanent-magnet synchronous motor, the rotor already has its own magnetic field. The controller determines the torque by controlling the stator currents and their relationship to that field.
The two motors can therefore produce very different torque responses even when their rotational speeds match the speed of a rotating magnetic field.
08Where this leads next
Torque-speed curves become especially useful when you compare them with the torque required by an actual machine.
That comparison determines whether a motor can start a load, accelerate it, maintain a particular speed, or provide regenerative braking.
The next useful concept is therefore motor-load matching: combining a motor’s torque-speed envelope with a load’s torque-speed curve to predict the system’s operating speed and determine whether the motor can safely meet its demands.