Why a DC Motor’s Electrical Input Exceeds Its Shaft Output
Learn why a DC motor converts only part of its electrical input into useful mechanical power. Explore energy losses, back EMF, efficiency calculations, and worked HSC Physics questions.
A small DC motor spins quickly when nothing is attached to its shaft. Connect it to a pulley lifting a weight, and the motor slows down. The current drawn from the power supply may increase, and the motor can become warm. If the motor receives 30 W of electrical power, why might only 20 W reach the pulley?
Because not all the electrical energy becomes useful mechanical output. Some heats the motor’s windings and electrical contacts, some is dissipated by friction and air resistance, and some may temporarily increase the rotational kinetic energy of the moving parts.
Here’s a prediction worth making: if you disconnect the pulley and the motor spins faster, does its useful mechanical output power increase?
Not necessarily. With no external load, the motor can spin rapidly while delivering almost no mechanical power to anything outside itself. Speed alone doesn’t tell you how much useful work a motor is doing.
01Where does a motor’s electrical input power go?
A motor transfers energy from an electrical supply into mechanical motion using the motor effect: the force experienced by a current-carrying conductor in a magnetic field.
But a real motor contains more than a current-carrying coil. It also has electrical contacts, bearings, an axle, and often an iron core. Each can affect how much of the input energy reaches an external load.
At constant rotational speed, the motor’s power budget is
\[ P_{\mathrm{in}}=P_{\mathrm{shaft}}+P_{\mathrm{loss}} \]
where:
- \(P_{\mathrm{in}}\) is the electrical power entering the motor, in watts (W).
- \(P_{\mathrm{shaft}}\) is the useful mechanical power delivered through the shaft to an external load, in watts.
- \(P_{\mathrm{loss}}\) is the rate at which energy is dissipated or otherwise fails to reach the external shaft load, in watts.
A motor can therefore have an efficiency below 100% without violating conservation of energy.
Follow the energy through a DC motor
Picture a simple DC motor with a rectangular coil between two magnetic poles.
Electrical current enters through stationary brushes, passes through a split-ring commutator, and flows around the coil. The magnetic field exerts forces on opposite sides of the coil, producing a turning effect.
The rotating coil drives the axle, which transfers mechanical power to the load.
Several components influence the energy budget.
| Component or process | Main function | Effect on the power budget |
|---|---|---|
| Coil windings | Carry current so magnetic forces can act | Electrical resistance produces heating |
| Magnetic field | Interacts with current to generate torque | Enables energy conversion; the field itself is not a separate source of energy |
| Brushes and commutator | Supply current to the rotating coil and reverse its direction at appropriate positions | Electrical contact resistance causes heating; friction also occurs |
| Bearings | Support the rotating axle | Friction dissipates mechanical energy |
| Rotor and surrounding air | Allow rotation within the motor | Air resistance produces drag |
| Iron core, where present | Helps guide and strengthen the magnetic field | Changing magnetisation and induced currents can produce additional heating |
| Output shaft | Delivers torque and rotation to the external load | This is where useful mechanical output is measured |
These effects are not equally important in every motor. A simple school motor might have substantial brush and bearing losses, while a different motor design may have different dominant losses.
The important idea is that electrical input power and useful shaft output power are measured at different points in the energy-transfer process.
Resistance produces heat even when the motor is turning
Current passing through a wire with resistance transfers energy into thermal energy.
For a winding of resistance \(R\),
\[ P_{\mathrm{copper}}=I^2R \]
Here, \(I\) is the winding current in amperes (A), \(R\) is its resistance in ohms (\(\Omega\)), and \(P_{\mathrm{copper}}\) is the power dissipated in the winding in watts.
These are called copper losses or resistive losses.
Notice the square on the current. If the current doubles while resistance stays constant, winding heating increases by a factor of four.
That gives us a reason why a heavily loaded motor can become hotter, even when it rotates more slowly than an unloaded motor.
02Why producing magnetic torque is not the same as delivering shaft power
A motor’s coil might experience a large magnetic turning force without delivering much useful output.
To understand why, separate two ideas:
- The magnetic field produces torque on the coil.
- Torque transfers mechanical power only when the shaft rotates through an angle.
Torque describes the turning effect of a force. Mechanical power describes how quickly that turning effect transfers energy.
The angle of the motor coil
For a simple rectangular coil in a uniform magnetic field, the magnitude of the magnetic torque is
\[ \tau_{\mathrm{mag}}=nBIA\sin\theta \]
where:
- \(\tau_{\mathrm{mag}}\) is the magnetic torque, in newton metres (N m).
- \(n\) is the number of turns in the coil.
- \(B\) is the magnetic flux density, in tesla (T).
- \(I\) is the current in the coil, in amperes.
- \(A\) is the area of one turn, in square metres (\(\mathrm{m^2}\)).
- \(\theta\) is the angle between the magnetic field and the normal to the coil’s plane.
The normal is a line perpendicular to the flat face of the coil.
If the question instead gives the acute angle \(\alpha\) between the plane of the coil and the magnetic field, then
\[ \theta=90^\circ-\alpha \]
and the torque magnitude becomes
\[ \tau_{\mathrm{mag}}=nBIA\cos\alpha \]
Why does the angle matter?
The component of the magnetic field lying in the coil’s plane produces the turning effect. Its magnitude is
\[ B_{\mathrm{plane}}=B\sin\theta \]
When the field lies entirely in the plane, this component is largest.
When the field points along the normal, that component is zero.
| Coil orientation | Normal-field angle \(\theta\) | Magnetic torque magnitude |
|---|---|---|
| Field perpendicular to coil plane | \(0^\circ\) | Zero |
| Field at \(30^\circ\) to coil normal | \(30^\circ\) | Half the maximum |
| Field parallel to coil plane | \(90^\circ\) | Maximum |
This describes the idealised instantaneous torque on the coil. In a simple brushed DC motor, the commutator reverses the coil current every half-turn so the torque continues to act in the intended rotational direction.
The commutator doesn’t remove electrical resistance, mechanical friction, or all torque variation.
For a fuller treatment of these angles, see how to choose the correct angle in a coil-torque equation.
A stalled motor exposes the misconception
Imagine holding the shaft still while current flows through the coil.
If the coil is appropriately oriented, the magnetic field still produces torque.
But the shaft isn’t rotating.
The useful mechanical power delivered through the shaft is therefore zero.
For rotational motion, the instantaneous mechanical power associated with a torque is
\[ P=\tau\omega \]
where \(\tau\) is the relevant torque in N m and \(\omega\) is angular velocity in radians per second (\(\mathrm{rad\,s^{-1}}\)). Positive torque is taken to act in the direction of rotation.
If the shaft is stationary,
\[ \omega=0 \]
so
\[ P_{\mathrm{shaft}}=\tau_{\mathrm{shaft}}(0)=0 \]
A non-zero torque does not guarantee non-zero mechanical power.
If electrical current continues flowing while the rotor is clamped, electrical energy is still being supplied. After brief electrical transients have settled, that input is dissipated mainly as heat in the windings and contacts.
This is why a stalled motor can overheat.
03How could you measure a motor’s efficiency experimentally?
The central experimental question is:
How much electrical power enters a motor, and how much mechanical power reaches an external load?
We can construct a measurement that answers both parts.
This is an illustrative experimental design, not a report of a historical experiment or a set of measurements performed by tutorgum.
First design: measure voltage, current, and speed
Start with a small DC motor connected to an adjustable DC power supply.
Place an ammeter in series with the motor to measure the current entering it. Connect a voltmeter directly across the motor terminals to measure the potential difference across the motor.
Attach a reflective marker to the rotating shaft and use an optical tachometer to measure rotational speed.
The electrical input power is
\[ P_{\mathrm{in}}=VI \]
where \(V\) is the terminal potential difference in volts (V), and \(I\) is the current in amperes.
This expression assumes a sufficiently steady DC supply. For rapidly varying voltage and current, electrical power must instead be evaluated from their variation with time.
Suppose the motor spins at 2400 revolutions per minute while drawing current.
Could we calculate its useful output power just from those measurements?
No. We know how much electrical power enters, and how quickly the rotor turns. We don’t know how much torque the shaft delivers to an external load.
A faster motor does not necessarily deliver greater mechanical power.
The first design therefore cannot establish the efficiency.
Revised design: add a measurable mechanical load
Now connect a small circular drum directly to the motor shaft. Wrap a friction belt around part of the drum, with each end held by a force gauge or spring balance.
As the drum rotates, one side of the belt becomes tighter than the other. The difference in the two belt tensions creates a braking torque on the drum.
This arrangement is a simple friction-brake dynamometer.
Let:
- \(T_{\mathrm{tight}}\) be the tension on the tighter side, in newtons.
- \(T_{\mathrm{slack}}\) be the tension on the other side, in newtons.
- \(r\) be the effective drum radius, in metres.
Assuming the belt forces act tangentially, the magnitude of the resisting torque is
\[ \tau_{\mathrm{load}} =(T_{\mathrm{tight}}-T_{\mathrm{slack}})r \]
At constant rotational speed, the motor delivers an equal magnitude of torque to the brake, assuming no significant power loss in the coupling.
We also need the angular speed.
If the tachometer displays speed in revolutions per minute (rpm), convert it using
\[ \omega=\frac{2\pi(\mathrm{rpm})}{60} \]
The factor \(2\pi\) converts revolutions to radians, while dividing by 60 converts minutes to seconds.
The shaft output power is then
\[ P_{\mathrm{shaft}}=\tau_{\mathrm{load}}\omega \]
and the motor efficiency is
\[ \eta=\frac{P_{\mathrm{shaft}}}{P_{\mathrm{in}}} \]
Multiplying \(\eta\) by 100 expresses efficiency as a percentage.
For a steady-state efficiency measurement, record voltage, current, speed, and brake tension after the rotational speed has settled.
What should we predict and observe?
If the motor converted all its electrical input power into useful shaft output, the two calculated powers would be equal whenever the speed was constant.
Real motors generally won’t satisfy that prediction.
Consider these constructed readings for a small motor.
Illustrative data only – not actual experimental measurements.
| Measurement | No external load | Brake applied |
|---|---|---|
| Motor terminal voltage | 12.0 V | 12.0 V |
| Current | 0.40 A | 2.0 A |
| Rotational speed | 2300 rpm | 1700 rpm |
| External shaft torque | Approximately 0 N m | 0.070 N m |
For the unloaded motor, the input power is
\[ P_{\mathrm{in}}=(12.0)(0.40)=4.8\ \mathrm{W} \]
Its useful external shaft output is approximately zero because no external load is being driven.
The incoming 4.8 W mainly supplies the motor’s internal electrical and mechanical losses while it maintains its speed.
For the loaded motor, the electrical input increases to 24 W.
The angular speed is approximately \(178\ \mathrm{rad\,s^{-1}}\), so the delivered shaft power is
\[ P_{\mathrm{shaft}}=(0.070)(178) \approx12.5\ \mathrm{W} \]
Approximately 11.5 W of the input does not reach the external shaft load.
This is the result our simple 100%-conversion prediction cannot explain.
What the revised experiment still cannot tell us
Subtracting output power from input power tells us the total power not reaching the shaft.
It does not automatically reveal how much went into copper heating, brush losses, bearing friction, or air drag.
For that, we need additional measurements or a more detailed motor model.
There is also an important boundary to understand.
The friction brake becomes warm because it absorbs mechanical power delivered by the motor shaft. That heat is produced outside the motor, in the measuring load.
It counts as mechanical shaft output for the motor efficiency calculation, even though the brake eventually converts that mechanical energy into thermal energy.
Do not subtract the brake’s heating as an internal motor loss.
04Worked example: How much input power is lost inside a motor?
A DC motor drives a small laboratory mixer directly through its shaft. At constant speed, the potential difference across the motor is 15.0 V, and the current is 1.60 A.
A torque sensor measures \(0.080\ \mathrm{N\,m}\) at the output shaft, while a tachometer reads 1800 rpm.
Calculate the electrical input power, mechanical output power, total power not delivered to the shaft, and efficiency.
Step 1
Use
\[ P_{\mathrm{in}}=VI \]
Substituting,
\[ \begin{aligned} P_{\mathrm{in}}&=(15.0)(1.60)\\ &=24.0\ \mathrm{W} \end{aligned} \]
The motor receives 24.0 J of electrical energy every second.
Step 2
The speed is supplied in rpm, but rotational power requires angular velocity in radians per second.
\[ \begin{aligned} \omega&=\frac{2\pi(1800)}{60}\\ &=188.5\ \mathrm{rad\,s^{-1}} \end{aligned} \]
Step 3
\[ \begin{aligned} P_{\mathrm{shaft}}&=\tau_{\mathrm{load}}\omega\\ &=(0.080)(188.5)\\ &=15.1\ \mathrm{W} \end{aligned} \]
The mixer receives approximately 15.1 J of mechanical energy each second.
Step 4
At constant rotational speed, the rotor isn’t accumulating rotational kinetic energy.
\[ \begin{aligned} P_{\mathrm{loss}} &=P_{\mathrm{in}}-P_{\mathrm{shaft}}\\ &=24.0-15.1\\ &=8.9\ \mathrm{W} \end{aligned} \]
The motor dissipates approximately 8.9 W internally, mainly through electrical and mechanical losses.
Step 5
\[ \begin{aligned} \eta&=\frac{P_{\mathrm{shaft}}}{P_{\mathrm{in}}}\\ &=\frac{15.1}{24.0}\\ &=0.628 \end{aligned} \]
Therefore,
\[ \eta=62.8\% \]
About 62.8% of the electrical input reaches the mixer as mechanical shaft power.
The remaining 37.2% is not available to the external load.
05Worked example: Testing a motor with a friction brake
A student designs a brake dynamometer for a small DC motor.
The motor operates at a steady 1700 rpm. The supply voltage measured at the terminals is 12.0 V, and the current is 2.50 A.
A belt runs around a drum of effective radius \(0.020\ \mathrm{m}\). The measured belt tensions are 9.0 N on the tight side and 3.0 N on the slack side.
Calculate the motor’s useful shaft output power, internal power loss, and efficiency.
The student then removes the belt. The motor spins freely at 2400 rpm and draws 0.45 A at the same 12.0 V. Explain what the second measurement reveals.
Step 1
Both belt tensions act on the drum, so we must use their difference.
\[ \begin{aligned} \tau_{\mathrm{load}} &=(T_{\mathrm{tight}}-T_{\mathrm{slack}})r\\ &=(9.0-3.0)(0.020)\\ &=0.120\ \mathrm{N\,m} \end{aligned} \]
Using only the 9.0 N tension would overestimate the resisting torque.
Step 2
\[ \begin{aligned} \omega&=\frac{2\pi(1700)}{60}\\ &=178.0\ \mathrm{rad\,s^{-1}} \end{aligned} \]
Step 3
\[ \begin{aligned} P_{\mathrm{shaft}}&=\tau_{\mathrm{load}}\omega\\ &=(0.120)(178.0)\\ &=21.4\ \mathrm{W} \end{aligned} \]
This is the mechanical power transferred to the brake through the rotating shaft.
Step 4
\[ \begin{aligned} P_{\mathrm{in}}&=(12.0)(2.50)\\ &=30.0\ \mathrm{W}\\[4pt] P_{\mathrm{loss}}&=30.0-21.4\\ &=8.6\ \mathrm{W} \end{aligned} \]
The motor’s internal losses account for approximately 8.6 W.
Step 5
\[ \begin{aligned} \eta&=\frac{21.4}{30.0}\times100\%\\ &=71.3\% \end{aligned} \]
The motor is approximately 71% efficient at this operating point.
Step 6
With the brake removed,
\[ \begin{aligned} P_{\mathrm{in,no\ load}} &=(12.0)(0.45)\\ &=5.4\ \mathrm{W} \end{aligned} \]
Although the motor now spins at 2400 rpm, it supplies approximately zero power to an external load.
At steady rotational speed, nearly all 5.4 W accounts for internal losses.
This doesn’t mean the motor’s internal losses are always 5.4 W.
The winding current, rotational speed, and potentially the motor temperature have changed between the two tests. Resistive heating and mechanical drag therefore need not remain constant.
You cannot simply subtract the unloaded loss from the loaded loss and claim that the difference represents one particular type of heating.
06Why a motor’s back EMF is not another energy loss
There’s another effect that explains why motor current changes with rotational speed.
As a motor’s coil rotates through the magnetic field, an electromotive force is induced in it.
This induced voltage opposes the applied voltage in normal motoring operation. It is called back electromotive force, or back EMF.
Predict what happens when a motor slows under a greater mechanical load.
You might expect its current to decrease because it’s rotating more slowly. But in a simple DC motor supplied at a fixed voltage, slowing reduces the back EMF. This generally allows more current to flow.
The extra current can produce greater electromagnetic torque, but it also increases resistive heating.
The simplified electrical model
For a permanent-magnet brushed DC motor, a useful idealised model is
\[ V=E_{\mathrm{back}}+IR \]
where:
- \(V\) is the applied terminal voltage, in volts.
- \(E_{\mathrm{back}}\) is the opposing induced voltage, in volts.
- \(I\) is the motor current, in amperes.
- \(R\) is the effective armature winding resistance, in ohms.
This simple model neglects brush voltage drops, changing inductive effects, and other electrical losses.
Multiply both sides by current:
\[ VI=E_{\mathrm{back}}I+I^2R \]
The two terms on the right have different meanings.
The term \(I^2R\) represents electrical power dissipated in the windings.
The term \(E_{\mathrm{back}}I\) represents gross electromagnetic power conversion into mechanical form in the idealised model.
That converted mechanical power must then overcome internal rotational losses before the remainder reaches the external shaft load.
Back EMF is therefore not an extra source of wasted power. It is a feature of the energy-conversion process.
Why a stalled motor behaves differently
In this model, back EMF is proportional to rotational speed.
At zero speed, back EMF is zero.
If the shaft becomes stalled while the voltage remains applied, the reduced opposing voltage can cause a much larger current.
The current may then generate a large magnetic torque but no useful mechanical power, because the shaft cannot rotate.
This is an important limit of the everyday idea that a motor uses electricity to produce movement.
A motor can draw substantial electrical power without moving at all.
Actual stall currents depend on the motor, supply limits, winding resistance, temperature, and control electronics. You should not deliberately stall a powered motor to test this without appropriate equipment and supervision.
07A reliable way to analyse a motor power question
When a question gives you voltage, current, speed, torque, or experimental readings, use the following sequence.
First, identify the operating condition.
Is the motor rotating at constant speed, accelerating, slowing down, or stalled?
The simple steady-state power balance assumes that rotational kinetic energy is not changing.
Second, identify what is crossing the motor’s boundary.
Electrical input enters at the motor terminals. Useful mechanical output is delivered through the shaft to the external load.
Heat generated in a brake, mixer, or other external load is not automatically an internal motor loss.
Third, calculate the two powers separately.
For steady DC conditions,
\[ P_{\mathrm{in}}=VI \]
For a directly coupled rotating shaft,
\[ P_{\mathrm{shaft}}=\tau_{\mathrm{load}}\omega \]
Use the delivered shaft torque, not automatically the ideal magnetic torque on the coil.
Fourth, apply conservation of energy.
At constant rotational speed,
\[ P_{\mathrm{loss}} =P_{\mathrm{in}}-P_{\mathrm{shaft}} \]
Then calculate efficiency if requested.
Finally, check whether the result is physically possible.
At steady speed, with electrical energy as the only input and no additional energy source, useful mechanical output cannot exceed electrical input.
If your answer suggests otherwise, inspect the torque measurement, speed conversion, system boundary, and assumptions.
A motor that is slowing down requires special care. Previously stored rotational kinetic energy can also help supply the load.
The final practice question explores exactly that situation.
08Questions and solutions
Question 1
A DC motor operates at a constant speed and receives 120 W of electrical power.
The useful mechanical power delivered through its shaft is 90 W.
Calculate:
a) The motor’s efficiency.
b) The power lost through internal processes.
c) The energy not delivered to the shaft during 20 seconds of operation, assuming both powers remain constant.
Solution 1
The motor is 75% efficient, its internal losses account for 30 W, and 600 J is not delivered to the shaft during the 20-second interval.
Part a: Efficiency
\[ \begin{aligned} \eta&=\frac{P_{\mathrm{shaft}}}{P_{\mathrm{in}}}\times100\%\\ &=\frac{90}{120}\times100\%\\ &=75\% \end{aligned} \]
This means 75% of the electrical input becomes useful mechanical shaft output.
Part b: Internal power loss
\[ \begin{aligned} P_{\mathrm{loss}}&=120-90\\ &=30\ \mathrm{W} \end{aligned} \]
The remaining power is dissipated through the motor’s internal electrical and mechanical processes.
Part c: Energy over 20 seconds
Energy transferred equals power multiplied by time.
\[ \begin{aligned} E_{\mathrm{loss}}&=P_{\mathrm{loss}}\Delta t\\ &=(30)(20)\\ &=600\ \mathrm{J} \end{aligned} \]
The tempting mistake is to say 600 J of energy has disappeared. It hasn’t. That energy has been transferred mainly into thermal energy rather than useful shaft output.
Question 2
A rectangular current-carrying coil is placed between the poles of a magnet. It has 20 turns, an area of \(4.0\times10^{-3}\ \mathrm{m^2}\) per turn, and carries a constant current of 1.0 A in a uniform magnetic field of 0.50 T.
The coil is held stationary by a rigid clamp. Electrical connections maintain the stated current at either orientation, with a terminal voltage of 8.0 V.
Two orientations are tested:
- Position A: The plane of the coil makes an angle of \(30^\circ\) with the magnetic field.
- Position B: The plane of the coil makes an angle of \(90^\circ\) with the magnetic field.
The current flows for 10 seconds in each test.
a) Calculate the magnetic torque magnitude in each position.
b) Compare the useful mechanical shaft output in the two positions.
c) Assuming the electrical input remains constant, negligible electrical energy is stored after initial transients, and the clamp does not move, compare the energy dissipated electrically during the two tests.
Explain why different magnetic torques do not necessarily mean different mechanical outputs.
Solution 2
Position A has a magnetic torque magnitude of approximately \(0.0346\ \mathrm{N\,m}\), while Position B has zero magnetic torque. Nevertheless, both deliver zero useful shaft power and dissipate 80 J of electrical energy under the stated assumptions.
Part a: Magnetic torque
The angle supplied is between the coil plane and magnetic field.
Therefore,
\[ \tau_{\mathrm{mag}}=nBIA\cos\alpha \]
For Position A,
\[ \begin{aligned} \tau_A &=(20)(0.50)(1.0)\\ &\quad\times(4.0\times10^{-3})\\ &\quad\times\cos30^\circ\\ &=0.0346\ \mathrm{N\,m} \end{aligned} \]
For Position B,
\[ \begin{aligned} \tau_B&=nBIA\cos90^\circ\\ &=0\ \mathrm{N\,m} \end{aligned} \]
Position A has a turning effect that the clamp must resist. Position B has no magnetic turning effect about the axle in this idealised arrangement.
Part b: Useful mechanical output
Both coils are stationary.
Their angular velocities are zero, so the useful mechanical power transferred through the clamped shafts is
\[ P_{\mathrm{shaft}}=\tau\omega=0 \]
The clamp in Position A experiences a reaction torque, but a stationary clamp does no mechanical work.
Part c: Electrical energy
Each coil receives
\[ \begin{aligned} P_{\mathrm{in}}&=VI\\ &=(8.0)(1.0)\\ &=8.0\ \mathrm{W} \end{aligned} \]
Over 10 seconds,
\[ \begin{aligned} E_{\mathrm{in}}&=P_{\mathrm{in}}\Delta t\\ &=(8.0)(10)\\ &=80\ \mathrm{J} \end{aligned} \]
With no rotation and no significant stored-energy change, the electrical energy is dissipated as heat in each test.
The subtle point is that torque measures a turning effect, not energy transfer by itself.
A student might expect Position A to use more energy because it has more torque. But without angular displacement, the magnetic torque does no mechanical work. Both tests have the same stated electrical input.
Question 3
A student tests a small DC motor using a friction brake.
The motor is supplied with 9.0 V and draws 2.0 A. It rotates at a constant 1500 rpm.
A belt wraps around a drum attached directly to the motor shaft. The effective drum radius is \(0.015\ \mathrm{m}\). The tight-side belt tension is 9.0 N, and the slack-side tension is 3.0 N.
The student calculates the braking torque using only the 9.0 N reading and concludes that the motor’s mechanical output exceeds its electrical input.
a) Reproduce the student’s mechanical power estimate.
b) Explain why this estimate creates a physical contradiction under the stated conditions.
c) Determine the correct mechanical output power and efficiency.
d) Explain why this contradiction would not automatically establish a measurement error if the motor were slowing down instead.
Solution 3
The student’s calculation gives an impossible steady-state output of approximately 21.2 W from an 18.0 W electrical input. The corrected output is 14.1 W, giving an efficiency of about 78.5%. During deceleration, however, stored rotational kinetic energy could temporarily supply additional output.
Part a: The student’s estimate
Using only the larger belt tension gives
\[ \begin{aligned} \tau_{\mathrm{wrong}}&=(9.0)(0.015)\\ &=0.135\ \mathrm{N\,m} \end{aligned} \]
Convert speed:
\[ \begin{aligned} \omega&=\frac{2\pi(1500)}{60}\\ &=157.1\ \mathrm{rad\,s^{-1}} \end{aligned} \]
The estimated mechanical output is
\[ \begin{aligned} P_{\mathrm{wrong}}&=(0.135)(157.1)\\ &=21.2\ \mathrm{W} \end{aligned} \]
Part b: The contradiction
Electrical input is
\[ P_{\mathrm{in}}=(9.0)(2.0)=18.0\ \mathrm{W} \]
The estimated output is greater than the only supplied input.
Because the shaft speed is constant, the motor’s rotational kinetic energy is not decreasing to provide the difference.
There is no additional energy source in the question.
The apparent efficiency would be
\[ \eta_{\mathrm{wrong}} =\frac{21.2}{18.0}\times100\% \approx118\% \]
This violates the steady-state energy budget and signals that an assumption or measurement calculation is wrong.
Part c: Correct the braking torque
Both sides of the friction belt contribute opposing turning effects.
The brake torque is determined by their difference:
\[ \begin{aligned} \tau_{\mathrm{load}} &=(9.0-3.0)(0.015)\\ &=0.090\ \mathrm{N\,m} \end{aligned} \]
Therefore,
\[ \begin{aligned} P_{\mathrm{shaft}} &=(0.090)(157.1)\\ &=14.1\ \mathrm{W} \end{aligned} \]
Efficiency becomes
\[ \begin{aligned} \eta&=\frac{14.1}{18.0}\times100\%\\ &=78.5\% \end{aligned} \]
The remaining input power is
\[ P_{\mathrm{loss}}=18.0-14.1=3.9\ \mathrm{W} \]
The corrected calculation is consistent with conservation of energy.
Part d: What changes during deceleration?
If the motor slows down, the rotational kinetic energy of the rotor and other attached rotating parts decreases.
That stored energy can also be delivered through the shaft.
Mechanical output can therefore temporarily exceed electrical input without violating conservation of energy.
The important constraint in the original problem is constant speed. It rules out a change in rotational kinetic energy and lets us identify the incorrect torque calculation.
Question 4
Consider an idealised permanent-magnet DC motor with the following steady operating conditions:
- Terminal voltage: 12.0 V
- Current: 3.0 A
- Effective winding resistance: \(1.0\ \Omega\)
- Angular speed: \(90\ \mathrm{rad\,s^{-1}}\)
- Useful output shaft torque: \(0.25\ \mathrm{N\,m}\)
Assume the only losses are winding resistance, bearing friction, and air drag. Ignore inductive transients and changes in winding resistance with temperature.
A student argues that the back EMF opposes the supply and therefore represents wasted electrical power.
a) Calculate the back EMF.
b) Calculate the electrical input power, winding heating, gross electromagnetic mechanical power, and useful shaft power.
c) Determine the power dissipated through bearing friction and air drag.
d) Suppose the shaft is suddenly clamped so it cannot rotate, while an ideal 12.0 V supply remains connected. Calculate the eventual current and winding heating predicted by this simplified model.
Explain why the current and heating differ from the running condition.
Solution 4
The running motor has 9.0 V of back EMF, receives 36.0 W electrically, converts 27.0 W into gross mechanical power, and delivers 22.5 W through the shaft. Bearing friction and air drag account for 4.5 W. If the motor stalls under the idealised fixed-voltage assumptions, current rises to 12 A, and winding heating rises to 144 W.
Part a: Back EMF
Using
\[ V=E_{\mathrm{back}}+IR \]
we obtain
\[ \begin{aligned} E_{\mathrm{back}}&=V-IR\\ &=12.0-(3.0)(1.0)\\ &=9.0\ \mathrm{V} \end{aligned} \]
Part b: Trace the power
Electrical input:
\[ \begin{aligned} P_{\mathrm{in}}&=VI\\ &=(12.0)(3.0)\\ &=36.0\ \mathrm{W} \end{aligned} \]
Winding heating:
\[ \begin{aligned} P_{\mathrm{copper}}&=I^2R\\ &=(3.0)^2(1.0)\\ &=9.0\ \mathrm{W} \end{aligned} \]
Gross electromagnetic power conversion:
\[ \begin{aligned} P_{\mathrm{converted}} &=E_{\mathrm{back}}I\\ &=(9.0)(3.0)\\ &=27.0\ \mathrm{W} \end{aligned} \]
Useful shaft output:
\[ \begin{aligned} P_{\mathrm{shaft}}&=\tau_{\mathrm{load}}\omega\\ &=(0.25)(90)\\ &=22.5\ \mathrm{W} \end{aligned} \]
The 27.0 W associated with back EMF is not another electrical loss.
It represents gross power converted into mechanical form by electromagnetic interaction.
Part c: Mechanical losses
The motor converts 27.0 W into mechanical power internally, but only 22.5 W reaches the load.
Therefore,
\[ \begin{aligned} P_{\mathrm{mechanical\ loss}} &=27.0-22.5\\ &=4.5\ \mathrm{W} \end{aligned} \]
Under the problem’s assumptions, this 4.5 W is dissipated through bearing friction and air drag.
The complete power budget is
\[ 36.0=9.0+4.5+22.5 \]
All quantities are in watts.
Part d: Stalled motor
When the shaft stops,
\[ \omega=0 \]
so the idealised back EMF becomes zero.
The model reduces to
\[ V=IR \]
Therefore,
\[ \begin{aligned} I_{\mathrm{stall}}&=\frac{V}{R}\\ &=\frac{12.0}{1.0}\\ &=12.0\ \mathrm{A} \end{aligned} \]
Winding heating becomes
\[ \begin{aligned} P_{\mathrm{copper,stall}} &=I_{\mathrm{stall}}^2R\\ &=(12.0)^2(1.0)\\ &=144\ \mathrm{W} \end{aligned} \]
The motor now receives 144 W electrically but delivers no useful mechanical power.
It can still experience substantial magnetic torque. The missing requirement is rotation.
The tempting prediction is that stopping the motor reduces its energy use. The opposite can occur: removing back EMF increases the current dramatically.
This result assumes an ideal supply maintaining 12.0 V and a fixed \(1.0\ \Omega\) resistance. Real supplies may limit current or shut down, and winding resistance changes as the motor heats. The calculation is a model prediction, not a safe operating procedure.
Question 5
A DC motor drives a heavy flywheel and a removable friction brake through one rigid shaft.
The motor and flywheel rotate together. Their combined rotational kinetic energy is known to be:
- 72 J at \(60\ \mathrm{rad\,s^{-1}}\)
- 32 J at \(40\ \mathrm{rad\,s^{-1}}\)
The system undergoes two consecutive stages.
Stage A – braking while powered
The motor remains connected to its electrical supply. The brake applies a constant resisting torque of \(1.08\ \mathrm{N\,m}\).
Over 2.0 seconds, the system slows uniformly from \(60\ \mathrm{rad\,s^{-1}}\) to \(40\ \mathrm{rad\,s^{-1}}\).
An electrical energy meter records 80 J entering the motor during this interval.
Stage B – recovery
The brake is completely disengaged.
The motor then accelerates the flywheel uniformly from \(40\ \mathrm{rad\,s^{-1}}\) back to \(60\ \mathrm{rad\,s^{-1}}\) over another 2.0 seconds.
The energy meter records a further 60 J entering the motor.
Assume there is no external mechanical energy input, no electrical energy returned to the supply, negligible energy stored in electromagnetic fields at the start and end of each stage, and no significant energy storage other than the flywheel’s rotational kinetic energy. All internal losses are dissipative.
Two students disagree.
Student A claims that Stage A proves the motor is more than 100% efficient because the brake can absorb more mechanical energy than the electrical supply provides during that stage.
Student B claims that the brake’s heating must be counted as an internal motor loss, so neither stage provides any useful mechanical output.
a) Determine the mechanical energy delivered to the brake in Stage A.
b) Calculate the energy dissipated internally during Stage A.
c) Determine the internal energy dissipation during Stage B.
d) Calculate the ratio of total mechanical energy delivered to the external brake to total electrical input over the complete two-stage cycle.
e) Evaluate both students’ claims and explain why the full cycle is more revealing than Stage A alone.
Solution 5
The brake receives 108 J during Stage A, even though the electrical supply provides only 80 J. This is possible because the flywheel releases 40 J of previously stored rotational kinetic energy. Internal losses are 12 J in Stage A and 20 J in Stage B. Across the complete cycle, 140 J of electrical input produces 108 J of external mechanical output and 32 J of internal dissipation, giving an overall energy-delivery ratio of approximately 77.1%.
Neither student’s explanation is correct.
Part a: Mechanical energy delivered during Stage A
Because angular speed decreases uniformly, the average angular speed is
\[ \begin{aligned} \omega_{\mathrm{avg}} &=\frac{60+40}{2}\\ &=50\ \mathrm{rad\,s^{-1}} \end{aligned} \]
The angular displacement over 2.0 seconds is
\[ \begin{aligned} \Delta\phi&=\omega_{\mathrm{avg}}\Delta t\\ &=(50)(2.0)\\ &=100\ \mathrm{rad} \end{aligned} \]
Here, \(\Delta\phi\) is angular displacement in radians.
For constant resisting torque, the magnitude of mechanical work delivered to the brake is
\[ W_{\mathrm{brake}} =\tau_{\mathrm{brake}}\Delta\phi \]
Therefore,
\[ \begin{aligned} W_{\mathrm{brake}} &=(1.08)(100)\\ &=108\ \mathrm{J} \end{aligned} \]
The brake absorbs 108 J of mechanical energy and dissipates it externally, mainly as heat.
Part b: Internal losses during Stage A
The combined motor and flywheel start with 72 J of rotational kinetic energy and finish with 32 J.
The decrease is
\[ \begin{aligned} E_{\mathrm{released}} &=72-32\\ &=40\ \mathrm{J} \end{aligned} \]
That energy is available in addition to the electrical energy entering during Stage A.
The complete energy budget is
\[ E_{\mathrm{in}}+K_i =W_{\mathrm{brake}}+E_{\mathrm{loss}}+K_f \]
where \(K_i\) and \(K_f\) are the initial and final rotational kinetic energies in joules, and \(E_{\mathrm{loss}}\) is the energy dissipated internally.
Rearranging,
\[ \begin{aligned} E_{\mathrm{loss,A}} &=80+72-108-32\\ &=12\ \mathrm{J} \end{aligned} \]
So Stage A is physically possible.
The brake receives 108 J, the motor receives 80 J electrically, and the flywheel supplies the additional 40 J needed to cover both the brake work and the motor’s 12 J of internal losses.
Part c: Internal losses during Stage B
The brake is disengaged, so no mechanical work is delivered to that external load.
The flywheel gains
\[ \begin{aligned} \Delta K&=72-32\\ &=40\ \mathrm{J} \end{aligned} \]
The motor receives 60 J electrically.
Therefore,
\[ \begin{aligned} E_{\mathrm{loss,B}} &=60-40\\ &=20\ \mathrm{J} \end{aligned} \]
The motor uses 40 J to restore the flywheel’s kinetic energy and dissipates 20 J internally.
The absence of a brake doesn’t mean that all 60 J is wasted. Some of the input becomes stored mechanical energy.
Part d: Evaluate the complete cycle
Total electrical input is
\[ \begin{aligned} E_{\mathrm{in,total}} &=80+60\\ &=140\ \mathrm{J} \end{aligned} \]
Total internal dissipation is
\[ \begin{aligned} E_{\mathrm{loss,total}} &=12+20\\ &=32\ \mathrm{J} \end{aligned} \]
Only Stage A delivers mechanical energy to the external brake.
Thus,
\[ W_{\mathrm{out,total}}=108\ \mathrm{J} \]
The ratio of mechanical energy delivered to the brake to electrical energy supplied over the complete cycle is
\[ \begin{aligned} \eta_{\mathrm{cycle}} &=\frac{108}{140}\times100\%\\ &=77.1\% \end{aligned} \]
This is the energy-delivery efficiency of the complete two-stage operating cycle, not the motor’s steady-state efficiency at one speed and load.
Conservation of energy is satisfied:
\[ 140=108+32 \]
The flywheel returns to its original rotational kinetic energy, so there is no net change in stored energy over the full cycle.
Part e: Evaluate the two claims
Student A’s calculation considers only Stage A:
\[ \frac{108}{80}\times100\%=135\% \]
The arithmetic is correct, but calling 135% the motor’s conversion efficiency is misleading.
It compares the total mechanical energy delivered during a deceleration with only the electrical energy supplied during that interval.
It ignores the 40 J released by the flywheel.
That release cannot continue indefinitely. If the same operation is to be repeated from the original speed, the flywheel must be accelerated again, which requires additional energy.
Student B’s reasoning also fails.
The brake converts the mechanical energy it receives into heat, but that conversion occurs outside the motor.
Mechanical energy has genuinely crossed the motor’s output boundary and entered the external brake.
The fact that the brake becomes warm doesn’t make the transferred energy an internal motor loss.
The full cycle resolves both mistakes:
- Stage A uses electrical energy and previously stored rotational energy.
- Stage B restores the stored rotational energy using additional electrical input.
- Over the complete cycle, the stored kinetic energy returns to its original value.
- The remaining electrical energy is accounted for by external mechanical work and internal dissipation.
The deeper lesson is that a power or efficiency calculation needs both a clearly defined system boundary and an understanding of how stored energy changes.
A ratio greater than 100% during a short interval is not automatically impossible. It becomes impossible as a sustained conversion efficiency only when additional energy inputs and changes in stored energy have been properly excluded.
08What motor power measurements tell you next
A motor’s electrical input power is not completely converted into useful mechanical output because some energy is dissipated internally through winding resistance, electrical contacts, friction, air drag, and other loss mechanisms.
The cleanest way to test how much reaches the load is to measure electrical power at the terminals and mechanical power at the shaft, under clearly stated operating conditions.
Three distinctions are worth keeping:
- Magnetic torque is not the same as useful shaft power. Rotation matters.
- A spinning motor isn’t necessarily doing much useful work. The external load matters.
- A difference between electrical input and shaft output is not always an internal loss. Changes in stored energy matter too.
The next useful connection is between rotational power, \(P=\tau\omega\), and the mechanical power delivered by a force acting on a moving object.
If the rotating motor drives a belt, trolley, or lifting mechanism, mechanical power using \(P=Fv\cos\theta\) provides the corresponding linear-motion method.
The same principle applies in both descriptions: useful mechanical power depends on the force or torque being delivered and the motion through which that force or torque acts.