Why More Generator Load Requires More Mechanical Input
Learn why drawing more current from a generator increases its opposing electromagnetic torque, and how Lenz's law explains the extra mechanical effort. Explore rotating-coil geometry, slip rings versus split rings, worked calculations, and challenging HSC Physics questions.
A hand-cranked generator spins fairly easily when nothing is connected to its terminals. Connect a lamp, and the handle becomes harder to turn. Connect another lamp in parallel, and it can become harder again.
Why should an electrical connection change how much force your hand must apply?
Predict what would happen if you connected more lamps but kept the generator spinning at exactly the same speed. Would the original turning effort still be enough?
No. Drawing more current produces a stronger opposing electromagnetic torque inside the generator. To maintain the same rotational speed, you must supply more mechanical torque and therefore more mechanical power.
That is the central answer: a generator converts mechanical work into electrical energy, and the induced current creates a magnetic effect that opposes the motion producing it. This is Lenz’s law in action.
The interesting part is that the generator can produce a voltage even when almost no current flows. Understanding the difference between producing a voltage and delivering electrical power explains why connecting a load changes the turning effort.
01The experiment: what actually makes the generator harder to turn?
Imagine investigating this using a small rotating-coil generator.
Inside the generator, a rectangular coil rotates between the north and south poles of a magnet. The magnetic field runs from the north pole towards the south pole.
The coil is attached to a shaft. Two ends of the coil connect to two metal slip rings that rotate with it. Stationary carbon brushes press against these rings, allowing current to pass between the rotating coil and an external circuit.
We can connect a resistor across the brushes to act as the electrical load.
To investigate mechanical effort, we also need to know how fast the shaft rotates and how much turning force is applied.
A controlled arrangement would contain:
- A driving motor connected to the generator shaft through a torque sensor.
- A tachometer measuring the shaft’s rotational speed.
- The rotating coil positioned between magnetic poles.
- Two slip rings and stationary brushes carrying electricity to the external circuit.
- An ammeter connected in series with a load resistor.
- A voltmeter connected across the load resistor.
The resistor should be approximately non-inductive, so we can initially treat the load as purely resistive.
First attempt: turn the generator by hand
Start with the resistor disconnected.
The shaft rotates, the coil moves through the magnetic field, and an alternating emf is induced. A high-resistance voltmeter connected across the terminals can detect that voltage.
However, almost no current flows because the external circuit is effectively open.
Now connect the resistor.
Current flows through the coil and external circuit. The generator develops an electromagnetic torque opposing its rotation, so maintaining the original speed requires additional effort.
That sounds like a convincing test. But there is a problem.
When someone turns a generator by hand, they may slow down as soon as the electrical load is connected. The induced emf then decreases because the coil is rotating more slowly.
We have changed two things at once: the electrical load and the rotational speed.
Revised experiment: keep the speed constant
Replace the hand crank with a driving motor whose speed can be controlled.
Measure the torque needed to maintain a chosen speed with the generator’s terminals open. Then connect different resistors while maintaining that same speed.
The expected results are:
- With the external circuit open, there is very little induced current, so the electromagnetic braking torque associated with that current is very small.
- Connecting a resistor allows current to flow and increases the opposing electromagnetic torque.
- Reducing the external resistance generally increases the current and the opposing torque, provided the rotational speed and magnetic field remain fixed.
- The driving motor must supply additional torque to maintain the selected speed.
There is an important experimental qualification. A real generator still experiences bearing friction, air resistance, and possibly magnetic losses when the external circuit is open. The torque measured in the open-circuit run provides a useful baseline.
We have described a proposed investigation and its theoretical predictions, not measurements from a particular experiment.
02Why the coil produces a voltage before it produces current
The generator’s behaviour starts with its geometry.
Picture the rectangular coil turning in a uniform magnetic field.
Imagine a short arrow sticking straight out of the coil’s surface. This is the normal to the coil, meaning a direction perpendicular to its plane.
The angle between this normal and the magnetic field determines the magnetic flux through the coil.
For a uniform magnetic field,
\[ \Phi=BA\cos\theta \]
where:
- \(\Phi\) is the signed magnetic flux through one turn, measured in webers (Wb).
- \(B\) is the magnetic flux density in tesla (T).
- \(A\) is the area enclosed by one turn, in square metres (\(\mathrm{m^2}\)).
- \(\theta\) is the angle between the coil’s normal and the magnetic field.
The direction chosen for the normal sets the positive direction of magnetic flux.
Predict where the voltage will be greatest
Suppose the normal points directly along the magnetic field.
The magnetic flux is at its maximum positive value, \(BA\).
Would the induced voltage also be greatest at this position?
It is tempting to say yes, because the most magnetic field passes through the coil.
But the induced emf depends on how quickly the flux changes, not simply on its value.
When the coil’s normal is exactly aligned with the field, the flux is momentarily changing at zero rate. The induced emf is zero at that instant.
After a quarter-turn, the coil’s normal is perpendicular to the magnetic field. The flux is zero, but it is changing at its greatest rate.
That is when the induced emf reaches its maximum magnitude.
Connecting geometry to Faraday’s law
For a coil with \(N\) identical turns, Faraday’s law gives
\[ \mathcal E=-N\frac{d\Phi}{dt} \]
Here, \(\mathcal E\) is the instantaneous induced electromotive force, measured in volts (V), \(N\) is the number of turns, and \(t\) is time in seconds.
The minus sign encodes Lenz’s law: the induced emf has the polarity that would drive a current opposing the change in magnetic flux.
For constant angular speed \(\omega\), measured in radians per second, let
\[ \theta=\omega t \]
with the coil’s normal aligned with the field at \(t=0\).
Substituting the flux equation and differentiating gives
\[ \begin{aligned} \Phi &=BA\cos(\omega t)\\ \mathcal E &=-N\frac{d\Phi}{dt}\\ &=NBA\omega\sin(\omega t) \end{aligned} \]
The positive emf direction is chosen consistently with the positive normal and the coil’s boundary direction.
The peak emf is therefore
\[ \mathcal E_0=NBA\omega \]
where \(\mathcal E_0\) is the maximum magnitude of the induced emf.
At a fixed magnetic field, coil geometry, and rotational speed, the generated emf has the same waveform whether the external circuit is open or connected to a resistor.
What changes when the resistor is connected is the current.
03Why current creates an opposing torque
Now connect the resistor.
The induced emf drives an electric current around the complete circuit. Each active side of the rotating coil is a current-carrying conductor in a magnetic field.
A current-carrying conductor experiences a magnetic force. In a generator, the forces on the opposite sides of the coil form a torque opposing the externally driven rotation.
This is often called counter-torque, electromagnetic braking torque, or electromagnetic reaction torque.
The effect follows Lenz’s law.
The induced current produces a magnetic effect that opposes the change responsible for producing the current. If the electromagnetic torque helped the generator rotate, it could supply both additional rotation and useful electrical energy without a corresponding energy input.
Instead, the driving motor or hand crank must do work against the opposing torque.
Why does the opposing torque increase with load?
For the simplest model, assume the external load is a resistor of resistance \(R\), while the generator’s winding has internal resistance \(r\).
Neglect coil inductance and brush resistance.
The instantaneous current is then
\[ i(t)=\frac{\mathcal E(t)}{R+r} \]
where \(i(t)\) is current in amperes (A).
At a fixed angular speed, the induced emf stays the same. Reducing \(R\) increases the current.
A greater current produces stronger magnetic forces on the coil conductors, increasing the opposing torque.
The current changes sign every half-turn in the rotating coil. However, the conductor positions also reverse relative to the magnetic field.
Consequently, for a purely resistive load, the electromagnetic torque continues to oppose the same direction of rotation.
The voltage alternates. The generator’s mechanical opposition does not alternate between helping and resisting the drive.
A bicycle dynamo provides a useful comparison. Drawing electrical power for the lights creates additional mechanical drag on the rotating wheel.
The comparison has a limit: the braking effect we are explaining is electromagnetic, not simply friction between contacting surfaces. Real dynamos also have mechanical friction even when their lights are disconnected.
Electrical power must come from mechanical work
For a sinusoidal emf and a purely resistive circuit, use root-mean-square values:
\[ E_{\mathrm{rms}}=\frac{\mathcal E_0}{\sqrt2} \]
and
\[ I_{\mathrm{rms}}=\frac{E_{\mathrm{rms}}}{R+r} \]
Here, \(E_{\mathrm{rms}}\) is the RMS emf generated inside the coil, and \(I_{\mathrm{rms}}\) is the RMS current.
The average electrical power delivered to the external resistor is
\[ P_{\mathrm{load}}=I_{\mathrm{rms}}^2R \]
The winding also heats because it has internal resistance:
\[ P_{\mathrm{winding}}=I_{\mathrm{rms}}^2r \]
Therefore, the average rate of electromagnetic energy conversion is
\[ P_{\mathrm{conv}} =I_{\mathrm{rms}}^2(R+r) \]
where all three powers are measured in watts (W).
At steady rotational speed,
\[ P_{\mathrm{shaft}} =P_{\mathrm{conv}}+P_{\mathrm{other}} \]
where \(P_{\mathrm{shaft}}\) is the mechanical power supplied at the generator shaft and \(P_{\mathrm{other}}\) accounts for bearing friction, air resistance, and other generator losses.
The shaft power is related to torque by
\[ P_{\mathrm{shaft}}=\tau_{\mathrm{drive}}\omega \]
where \(\tau_{\mathrm{drive}}\) is the applied driving torque in newton metres (N m).
Choose the direction of rotation as positive. The driving torque is positive, while the electromagnetic torque on the rotor is negative.
Ignoring other losses, the magnitude of the average electromagnetic counter-torque is
\[ |\overline{\tau}_{\mathrm{em}}| =\frac{P_{\mathrm{conv}}}{\omega} \]
If the speed stays constant, more converted electrical power means more opposing torque.
This is an application of energy transfer, rather than a claim that the generator’s mechanical energy is conserved. For the broader distinction, see Conservation of Mechanical Energy for HSC Physics.
04What the experiment should reveal: illustrative data
Consider a simplified generator with these properties:
- Constant angular speed of \(20\ \mathrm{rad\,s^{-1}}\).
- Internally generated RMS emf of \(12\ \mathrm V\).
- Winding resistance of \(2.0\ \Omega\).
- Negligible mechanical friction, magnetic losses, and inductance.
The following values are calculated predictions, not experimental measurements.
| External resistance | RMS current | Terminal RMS voltage | Power delivered to load | Average counter-torque magnitude |
|---|---|---|---|---|
| Open circuit | 0 A | 12 V | 0 W | 0 N m |
| \(10\ \Omega\) | 1 A | 10 V | 10 W | 0.60 N m |
| \(4.0\ \Omega\) | 2 A | 8 V | 16 W | 1.20 N m |
| \(1.0\ \Omega\) | 4 A | 4 V | 16 W | 2.40 N m |
For example, with the \(4.0\ \Omega\) load,
\[ I_{\mathrm{rms}} =\frac{12}{4.0+2.0} =2.0\ \mathrm A \]
The power converted electromagnetically is
\[ \begin{aligned} P_{\mathrm{conv}} &=(2.0)^2(4.0+2.0)\\ &=24\ \mathrm W \end{aligned} \]
so
\[ |\overline{\tau}_{\mathrm{em}}| =\frac{24}{20} =1.20\ \mathrm{N\,m} \]
Notice something unusual in the final two rows.
Both resistors receive \(16\ \mathrm W\), but the \(1.0\ \Omega\) load requires twice the electromagnetic torque.
Why?
The smaller resistance draws more current, causing much greater heating in the generator’s own winding. More mechanical power is being converted, even though the useful power delivered to the external resistor is unchanged.
This is why generator load must be described carefully.
A lower external resistance generally means greater current demand at fixed speed. It does not necessarily mean greater useful power delivered to the load when the generator has internal resistance.
05Worked example: Calculate the extra torque required
A rotating-coil AC generator has \(100\) turns, each enclosing an area of \(0.010\ \mathrm{m^2}\). The coil rotates at \(100\ \mathrm{rad\,s^{-1}}\) in a uniform magnetic field of \(0.20\ \mathrm T\).
The generator’s internal resistance is \(2.0\ \Omega\), and an \(8.0\ \Omega\) resistor is connected across its slip-ring terminals.
Calculate the RMS current, power delivered to the load, and average electromagnetic counter-torque. Assume sinusoidal operation, negligible inductance, and negligible mechanical losses.
Step 1
Use Faraday’s law for a uniformly rotating coil:
\[ \mathcal E_0=NBA\omega \]
Substitute the given values:
\[ \begin{aligned} \mathcal E_0 &=(100)(0.20)(0.010)(100)\\ &=20\ \mathrm V \end{aligned} \]
The peak induced emf is \(20\ \mathrm V\).
Step 2
The RMS emf is
\[ E_{\mathrm{rms}} =\frac{20}{\sqrt2} =14.14\ \mathrm V \]
The total circuit resistance includes the generator’s winding:
\[ R_{\mathrm{total}}=8.0+2.0=10.0\ \Omega \]
Therefore,
\[ \begin{aligned} I_{\mathrm{rms}} &=\frac{14.14}{10.0}\\ &=1.414\ \mathrm A \end{aligned} \]
Step 3
\[ \begin{aligned} P_{\mathrm{load}} &=I_{\mathrm{rms}}^2R\\ &=(1.414)^2(8.0)\\ &\approx16.0\ \mathrm W \end{aligned} \]
The external resistor receives approximately \(16\ \mathrm W\).
Step 4
\[ \begin{aligned} P_{\mathrm{winding}} &=I_{\mathrm{rms}}^2r\\ &=(1.414)^2(2.0)\\ &\approx4.0\ \mathrm W \end{aligned} \]
The total electromagnetic conversion power is
\[ P_{\mathrm{conv}}=16.0+4.0=20.0\ \mathrm W \]
Step 5
\[ \begin{aligned} |\overline{\tau}_{\mathrm{em}}| &=\frac{P_{\mathrm{conv}}}{\omega}\\ &=\frac{20.0}{100}\\ &=0.20\ \mathrm{N\,m} \end{aligned} \]
The generator produces an average opposing electromagnetic torque of \(0.20\ \mathrm{N\,m}\).
With mechanical losses neglected, the drive must supply an additional \(0.20\ \mathrm{N\,m}\) compared with the open-circuit condition to maintain the same speed.
The important detail is that the mechanical input corresponds to \(20\ \mathrm W\), not just the \(16\ \mathrm W\) delivered to the external resistor.
06Why slip rings and split rings do not remove the need for mechanical work
The contact arrangement changes the voltage waveform observed in the external circuit. It does not eliminate the electromagnetic reaction torque.
A simple rotating-coil generator commonly uses one of two arrangements.
Slip rings: alternating current output
Each end of the rotating coil connects permanently to its own complete metal ring.
A stationary brush contacts each ring.
Because the connections do not swap, the external voltage reverses polarity whenever the induced emf reverses.
For the ideal sinusoidal model, the external output is alternating current (AC).
Split-ring commutator: pulsating direct current output
Instead of two complete rings, the coil ends connect to two insulated half-ring segments.
As the coil completes each half-turn, the segments swap which stationary brush they contact.
This reverses the coil’s connection to the external circuit at the same time that the induced emf changes polarity.
The external voltage therefore keeps the same polarity but rises and falls in pulses.
This is pulsating direct current (DC), not a constant DC voltage.
| Feature | Slip rings | Split-ring commutator |
|---|---|---|
| Rotating contacts | Two complete rings | Two insulated half-ring segments |
| External voltage | Alternating polarity | One polarity, pulsating |
| Coil’s internally induced emf | Alternates | Alternates |
| Current in the rotating coil with a resistive load | Reverses every half-turn | Reverses every half-turn |
| Electromagnetic reaction torque | Opposes rotation | Opposes rotation |
For a simple coil with the same speed, resistance, and magnetic field, an ideal commutator changes the external polarity but not the amount of energy converted.
The RMS load current and average power remain the same for an ideal resistive load, even though the external waveforms look different.
A split-ring commutator is not a device for obtaining electrical power without increasing mechanical effort.
For a detailed examination of its switching geometry, see How a Split-Ring Commutator Changes a Generator’s Waveform.
07Worked example: What does the torque sensor actually measure?
A speed-controlled generator rotates at \(60\ \mathrm{rad\,s^{-1}}\).
With its terminals open, the driving motor must supply a torque of \(0.080\ \mathrm{N\,m}\) to overcome bearing friction and other mechanical losses.
An external \(6.0\ \Omega\) resistor is then connected. The generator’s winding resistance is \(1.5\ \Omega\), and the measured RMS current is \(2.0\ \mathrm A\).
Calculate the electromagnetic conversion power, the total driving torque, and the mechanical shaft power after the resistor is connected.
Assume sinusoidal operation, negligible inductance, and that the torque from mechanical losses remains \(0.080\ \mathrm{N\,m}\).
Step 1
\[ \begin{aligned} P_{\mathrm{load}} &=I_{\mathrm{rms}}^2R\\ &=(2.0)^2(6.0)\\ &=24\ \mathrm W \end{aligned} \]
Step 2
\[ \begin{aligned} P_{\mathrm{winding}} &=I_{\mathrm{rms}}^2r\\ &=(2.0)^2(1.5)\\ &=6.0\ \mathrm W \end{aligned} \]
The electromagnetic conversion power is
\[ P_{\mathrm{conv}}=24+6=30\ \mathrm W \]
The electrical circuit requires \(30\ \mathrm W\) of converted power, although only \(24\ \mathrm W\) reaches the external resistor.
Step 3
\[ \begin{aligned} |\overline{\tau}_{\mathrm{em}}| &=\frac{30}{60}\\ &=0.50\ \mathrm{N\,m} \end{aligned} \]
Step 4
The applied driving torque must balance both the electromagnetic counter-torque and the mechanical resistance:
\[ \begin{aligned} \tau_{\mathrm{drive}} &=0.50+0.080\\ &=0.58\ \mathrm{N\,m} \end{aligned} \]
The driving motor therefore needs to supply \(0.58\ \mathrm{N\,m}\) to maintain the speed.
Step 5
\[ \begin{aligned} P_{\mathrm{shaft}} &=\tau_{\mathrm{drive}}\omega\\ &=(0.58)(60)\\ &=34.8\ \mathrm W \end{aligned} \]
The \(34.8\ \mathrm W\) of mechanical input is distributed as follows:
- \(24.0\ \mathrm W\) reaches the external resistor.
- \(6.0\ \mathrm W\) heats the generator winding.
- \(4.8\ \mathrm W\) overcomes mechanical losses.
The power balance is
\[ 34.8=24.0+6.0+4.8\ \mathrm W \]
This is why a torque sensor is so useful in a generator investigation. It measures the mechanical demand at the shaft, including losses that cannot be inferred from the external resistor’s power alone.
08What changes if the generator is allowed to slow down?
So far, we have deliberately kept the rotational speed constant.
But a person turning a crank, a small wind turbine, or a motor with limited driving torque may not maintain a fixed speed when the electrical load changes.
Suppose the load increases while the driving torque stays the same.
Immediately, the generator develops a greater opposing torque. The shaft slows.
Because peak emf depends on angular speed,
\[ \mathcal E_0=NBA\omega \]
the induced emf decreases as the generator slows.
That lower emf can reduce the current and the electromagnetic counter-torque until a new steady speed is reached.
The outcomes depend on what is controlled:
| Driving condition | Possible response to lower external resistance |
|---|---|
| Constant speed | More current and greater electromagnetic counter-torque |
| Constant driving torque | Generator slows; induced emf falls |
| Limited driving power | Speed and delivered electrical power may change together |
| Open circuit | Emf may still be produced, but little current or external electrical power is delivered |
Do not confuse a lower resistance with a guaranteed increase in useful output power.
For a generator with significant internal resistance, the terminal voltage can fall as current increases. If the generator also slows, the internally generated emf falls as well.
This is the distinction that prevents many incorrect generator explanations.
09Questions and solutions
Question 1
An ideal AC generator produces an RMS emf of \(18\ \mathrm V\) while rotating at \(30\ \mathrm{rad\,s^{-1}}\).
A \(9.0\ \Omega\) resistor is connected across its terminals.
Assume negligible internal resistance, inductance, and mechanical losses.
Calculate:
a. The RMS current through the resistor.
b. The electrical power delivered to the resistor.
c. The average electromagnetic counter-torque magnitude.
d. What happens to the induced emf and electromagnetic counter-torque if the circuit is opened while the rotational speed remains constant.
Solution 1
The generator supplies \(2.0\ \mathrm A\) and \(36\ \mathrm W\), producing an average counter-torque magnitude of \(1.2\ \mathrm{N\,m}\). Opening the circuit removes the load current and electromagnetic counter-torque, but it does not remove the induced emf.
Part a: Current
Use Ohm’s law:
\[ \begin{aligned} I_{\mathrm{rms}} &=\frac{E_{\mathrm{rms}}}{R}\\ &=\frac{18}{9.0}\\ &=2.0\ \mathrm A \end{aligned} \]
Part b: Electrical power
\[ \begin{aligned} P_{\mathrm{load}} &=I_{\mathrm{rms}}^2R\\ &=(2.0)^2(9.0)\\ &=36\ \mathrm W \end{aligned} \]
Part c: Counter-torque
With losses neglected, the mechanical input equals the electrical output.
\[ \begin{aligned} |\overline{\tau}_{\mathrm{em}}| &=\frac{P_{\mathrm{load}}}{\omega}\\ &=\frac{36}{30}\\ &=1.2\ \mathrm{N\,m} \end{aligned} \]
This torque opposes the imposed rotation.
Part d: Open circuit
At the same speed and magnetic field, Faraday’s law gives the same \(18\ \mathrm V\) RMS induced emf.
However, the open circuit prevents significant current from flowing, so there is no load-induced electromagnetic counter-torque in this ideal model.
A common mistake is to assume that disconnecting the resistor stops electromagnetic induction. Rotation and changing flux produce the emf; a complete conducting circuit is needed for sustained current and electrical power delivery.
Question 2
A \(100\)-turn generator coil rotates at a constant angular speed of \(50\ \mathrm{rad\,s^{-1}}\).
The magnetic flux through each turn is
\[ \Phi=3.0\times10^{-3}\cos\theta \]
where flux is measured in webers and \(\theta\) is the coil’s angular position in radians.
The coil is connected to an \(8.0\ \Omega\) external resistor and has \(2.0\ \Omega\) internal resistance. Neglect inductance and mechanical losses.
Take increasing \(\theta\) as positive rotation and use the induced emf sign convention from Faraday’s law.
a. Determine the instantaneous induced emf and current when \(\theta=0^\circ\) and when \(\theta=90^\circ\).
b. Calculate the instantaneous electromagnetic counter-torque magnitude at both positions.
c. At \(\theta=270^\circ\), the emf and current have reversed sign. Determine whether the electromagnetic torque now assists or opposes rotation, explaining your reasoning.
Solution 2
The emf and current are zero at \(0^\circ\), reach \(+15\ \mathrm V\) and \(+1.5\ \mathrm A\) at \(90^\circ\), and reverse sign at \(270^\circ\). The electromagnetic torque still opposes rotation at both quarter-turn positions, with magnitude \(0.45\ \mathrm{N\,m}\).
Part a: Calculate emf and current
Faraday’s law gives
\[ \mathcal E=-N\frac{d\Phi}{dt} \]
Because \(d\theta/dt=\omega\),
\[ \mathcal E =N(3.0\times10^{-3})\omega\sin\theta \]
Substitute \(N=100\) and \(\omega=50\ \mathrm{rad\,s^{-1}}\):
\[ \mathcal E=15\sin\theta\ \mathrm V \]
The total circuit resistance is
\[ R+r=8.0+2.0=10.0\ \Omega \]
Therefore,
\[ i=\frac{15\sin\theta}{10.0} =1.5\sin\theta\ \mathrm A \]
At \(0^\circ\),
\[ \mathcal E=0\ \mathrm V,\qquad i=0\ \mathrm A \]
At \(90^\circ\),
\[ \mathcal E=+15\ \mathrm V,\qquad i=+1.5\ \mathrm A \]
Part b: Instantaneous counter-torque
At constant angular speed, the instantaneous electromagnetic conversion power is
\[ p_{\mathrm{conv}}=\mathcal E i \]
At \(0^\circ\), both emf and current are zero, so converted power and electromagnetic counter-torque are zero.
At \(90^\circ\),
\[ \begin{aligned} p_{\mathrm{conv}} &=(15)(1.5)\\ &=22.5\ \mathrm W \end{aligned} \]
The instantaneous opposing torque magnitude is
\[ \begin{aligned} |\tau_{\mathrm{em}}| &=\frac{22.5}{50}\\ &=0.45\ \mathrm{N\,m} \end{aligned} \]
Part c: Reverse emf does not mean reverse braking
At \(270^\circ\),
\[ \begin{aligned} \mathcal E&=-15\ \mathrm V\\ i&=-1.5\ \mathrm A \end{aligned} \]
The electromagnetic conversion power is
\[ p_{\mathrm{conv}} =(-15)(-1.5) =+22.5\ \mathrm W \]
The converted power remains positive. Mechanical energy is still being transferred into electrical energy.
The torque on the rotor is therefore still opposite to positive rotation, with magnitude \(0.45\ \mathrm{N\,m}\).
The tempting mistake is to reverse the torque whenever the current reverses.
That ignores the fact that the coil’s physical orientation has also changed. Both current direction and conductor position must be considered when determining the magnetic torque.
Question 3
A single-coil generator produces an internal peak emf of \(24\ \mathrm V\) while rotating at \(40\ \mathrm{rad\,s^{-1}}\).
Its winding resistance is \(2.0\ \Omega\), and it powers a purely resistive \(10.0\ \Omega\) load.
Two versions are constructed using identical coils, magnetic fields, and rotational speeds:
- Generator A uses two slip rings.
- Generator B uses a split-ring commutator.
Assume ideal contacts, negligible inductance, and negligible mechanical losses.
A student argues:
“Generator A has zero average terminal voltage, so it should deliver zero average electrical power. Generator B gives positive voltage pulses, so it must require more mechanical input.”
a. Describe the external voltage waveform for each generator, including its peak value.
b. Calculate the average electrical power delivered to the load in each case.
c. Determine the average electromagnetic counter-torque magnitude in each generator.
d. Explain precisely why the student’s argument fails.
Solution 3
Both generators deliver \(20\ \mathrm W\) to their resistors and require the same average electromagnetic counter-torque magnitude of \(0.60\ \mathrm{N\,m}\). Different voltage polarities do not imply different average powers.
Part a: Output waveforms
The total resistance in each generator circuit is
\[ R+r=10.0+2.0=12.0\ \Omega \]
The peak current magnitude is
\[ i_0=\frac{24}{12.0}=2.0\ \mathrm A \]
The peak terminal voltage magnitude across the external resistor is
\[ V_0=i_0R=(2.0)(10.0)=20.0\ \mathrm V \]
For Generator A, with slip rings,
\[ v_A(t)=20\sin(\omega t) \]
For Generator B, choosing the positive brush polarity,
\[ v_B(t)=20|\sin(\omega t)| \]
Both expressions give voltage in volts.
Generator A produces an alternating sinusoidal output. Generator B produces a full-wave pulsating output with one polarity.
Part b: Average power
Both waveforms have the same RMS magnitude because reversing the sign of a voltage does not change its square.
\[ V_{\mathrm{rms}} =\frac{20}{\sqrt2} =14.14\ \mathrm V \]
Therefore, in both circuits,
\[ \begin{aligned} P_{\mathrm{load}} &=\frac{V_{\mathrm{rms}}^2}{R}\\ &=\frac{(14.14)^2}{10.0}\\ &\approx20.0\ \mathrm W \end{aligned} \]
Part c: Electromagnetic torque
The RMS current in either circuit is
\[ I_{\mathrm{rms}} =\frac{2.0}{\sqrt2} =1.414\ \mathrm A \]
The internal winding dissipates
\[ \begin{aligned} P_{\mathrm{winding}} &=(1.414)^2(2.0)\\ &\approx4.0\ \mathrm W \end{aligned} \]
Thus, each generator converts
\[ P_{\mathrm{conv}}=20.0+4.0=24.0\ \mathrm W \]
The average counter-torque magnitude is
\[ \begin{aligned} |\overline{\tau}_{\mathrm{em}}| &=\frac{24.0}{40}\\ &=0.60\ \mathrm{N\,m} \end{aligned} \]
Part d: Why the argument fails
The student’s mistake is treating average signed voltage as average electrical power.
Power in a resistor depends on the square of voltage or current:
\[ p(t)=\frac{v(t)^2}{R} \]
A negative voltage produces negative current through the same positive resistance. Their product is still positive.
Consequently, both positive and negative AC half-cycles transfer energy to the resistor.
The split-ring commutator changes the external connections, not the amount of mechanical energy needed to produce the same current and resistive heating.
The electromagnetic counter-torque remains opposite to rotation in both machines.
Question 4
A student investigates a generator using a driving motor, torque sensor, voltmeter, and adjustable load resistor.
The generator has \(1.0\ \Omega\) internal resistance. Its internally generated RMS emf is directly proportional to rotational speed.
The following are illustrative readings from two proposed operating conditions, not records from a real experiment.
| Run | External resistance | Angular speed | Driving torque | Terminal RMS voltage |
|---|---|---|---|---|
| A | Open circuit | \(80\ \mathrm{rad\,s^{-1}}\) | \(0.100\ \mathrm{N\,m}\) | \(12.0\ \mathrm V\) |
| B | \(5.0\ \Omega\) | \(60\ \mathrm{rad\,s^{-1}}\) | \(0.325\ \mathrm{N\,m}\) | \(7.5\ \mathrm V\) |
Assume a purely resistive circuit, negligible inductance, and constant mechanical-loss torque of \(0.100\ \mathrm{N\,m}\).
a. Explain why the terminal voltage in Run B is lower than in Run A. Quantify the two separate causes.
b. Show that the measured driving torque in Run B is consistent with the energy-conversion model.
c. Predict the driving torque and load power if the \(5.0\ \Omega\) resistor remains connected but the motor maintains \(80\ \mathrm{rad\,s^{-1}}\).
d. Explain how this revised test provides stronger evidence for the relationship between electrical load and mechanical input.
Solution 4
The loaded terminal voltage falls because the generator both slows down and develops an internal voltage drop. Run B is consistent with the model, and maintaining \(80\ \mathrm{rad\,s^{-1}}\) with the resistor connected would require \(0.400\ \mathrm{N\,m}\) of driving torque.
Part a: Separate the two voltage effects
In Run A, the external circuit is open, so current is approximately zero. The terminal voltage equals the internally generated RMS emf:
\[ E_A=12.0\ \mathrm V \]
Since emf is proportional to angular speed,
\[ \frac{E_B}{E_A} =\frac{\omega_B}{\omega_A} \]
Therefore,
\[ \begin{aligned} E_B &=12.0\left(\frac{60}{80}\right)\\ &=9.0\ \mathrm V \end{aligned} \]
The decrease in speed reduces the internally generated emf by \(3.0\ \mathrm V\).
The total resistance in Run B is
\[ R+r=5.0+1.0=6.0\ \Omega \]
The current is
\[ I_B=\frac{9.0}{6.0}=1.5\ \mathrm A \]
The internal voltage drop is
\[ I_Br=(1.5)(1.0)=1.5\ \mathrm V \]
Thus,
\[ V_B=9.0-1.5=7.5\ \mathrm V \]
The total terminal voltage reduction is \(4.5\ \mathrm V\): \(3.0\ \mathrm V\) comes from reduced speed, and \(1.5\ \mathrm V\) comes from internal resistance.
Part b: Test the measured torque
The electromagnetic conversion power in Run B is
\[ \begin{aligned} P_{\mathrm{conv}} &=I_B^2(R+r)\\ &=(1.5)^2(6.0)\\ &=13.5\ \mathrm W \end{aligned} \]
The electromagnetic counter-torque magnitude is
\[ \begin{aligned} |\overline{\tau}_{\mathrm{em}}| &=\frac{13.5}{60}\\ &=0.225\ \mathrm{N\,m} \end{aligned} \]
Adding the constant mechanical-loss torque gives
\[ \tau_{\mathrm{drive}} =0.225+0.100 =0.325\ \mathrm{N\,m} \]
This agrees with the illustrative Run B torque reading.
Part c: Maintain the original speed
At \(80\ \mathrm{rad\,s^{-1}}\), the generated RMS emf returns to \(12.0\ \mathrm V\).
With the \(5.0\ \Omega\) load connected,
\[ I=\frac{12.0}{5.0+1.0}=2.0\ \mathrm A \]
The electromagnetic conversion power is
\[ \begin{aligned} P_{\mathrm{conv}} &=(2.0)^2(6.0)\\ &=24.0\ \mathrm W \end{aligned} \]
The electromagnetic counter-torque magnitude becomes
\[ |\overline{\tau}_{\mathrm{em}}| =\frac{24.0}{80} =0.300\ \mathrm{N\,m} \]
Adding the mechanical-loss torque,
\[ \tau_{\mathrm{drive}} =0.300+0.100 =0.400\ \mathrm{N\,m} \]
The power delivered to the external resistor is
\[ \begin{aligned} P_{\mathrm{load}} &=(2.0)^2(5.0)\\ &=20.0\ \mathrm W \end{aligned} \]
The total shaft power is \(0.400\times80=32.0\ \mathrm W\), consisting of \(20.0\ \mathrm W\) load power, \(4.0\ \mathrm W\) winding heating, and \(8.0\ \mathrm W\) mechanical losses.
Part d: Why speed control matters
The original test changed both load and speed.
Although the measurements are consistent with electromagnetic braking, the lower generated emf in Run B complicates a direct comparison.
The revised test compares the open-circuit and loaded generator at the same angular speed.
The induced emf remains fixed, so the additional driving torque can be attributed to the load current, provided the other losses are unchanged.
The tempting approach is to interpret the entire \(4.5\ \mathrm V\) terminal decrease as an internal resistance drop, or to compare the two torque readings without considering speed. Both ignore an important variable.
Question 5
A generator is driven by a mechanism that supplies a constant average torque, not a constant speed.
The generator has internal resistance \(r=2.0\ \Omega\), and its internally generated RMS emf is proportional to angular speed.
When rotating at \(20\ \mathrm{rad\,s^{-1}}\), it produces an internally generated RMS emf of \(12.0\ \mathrm V\).
Initially, a \(10.0\ \Omega\) resistor is connected across its terminals. The generator runs steadily at \(20\ \mathrm{rad\,s^{-1}}\), and the driving mechanism supplies a constant average torque of \(0.600\ \mathrm{N\,m}\).
The external resistor is suddenly replaced with a \(4.0\ \Omega\) resistor. The driving mechanism continues supplying exactly \(0.600\ \mathrm{N\,m}\), and the generator eventually reaches a new steady rotational speed.
Assume a purely resistive circuit, negligible inductance and mechanical losses, and sufficient rotational inertia to make the steady speeds approximately constant over each electrical cycle. Use cycle-averaged powers and torques. The driving mechanism has no speed regulator, and a stable non-zero steady speed is possible.
a. Immediately after the resistor changes, before the speed has changed appreciably, determine the new RMS current and electromagnetic counter-torque magnitude. Predict the initial change in rotational speed.
b. Calculate the new steady angular speed and RMS current.
c. Determine the mechanical input power and external load power before and after the resistor change.
d. Explain why the result does not contradict Lenz’s law, even if the mechanical input power decreases after connecting the smaller resistance.
e. State what would be different if the driving mechanism instead maintained a constant speed of \(20\ \mathrm{rad\,s^{-1}}\).
Solution 5
The generator initially slows down, then settles at \(10\ \mathrm{rad\,s^{-1}}\) with an RMS current of \(1.0\ \mathrm A\). Its mechanical input power falls from \(12\ \mathrm W\) to \(6.0\ \mathrm W\), even though the external resistance has decreased.
The crucial constraint is that the driving torque, rather than the rotational speed, is fixed.
Part a: What happens immediately after switching?
Before the change, the current is
\[ I_1=\frac{12.0}{10.0+2.0}=1.0\ \mathrm A \]
The electromagnetic conversion power is
\[ P_1=(1.0)^2(12.0)=12.0\ \mathrm W \]
Therefore, the opposing torque magnitude is
\[ |\overline{\tau}_{\mathrm{em},1}| =\frac{12.0}{20} =0.600\ \mathrm{N\,m} \]
This balances the driving torque, explaining the initial steady rotation.
Immediately after switching to \(4.0\ \Omega\), the angular speed has not yet changed appreciably, so the generated emf is still \(12.0\ \mathrm V\) RMS.
The current becomes
\[ I_{\mathrm{immediate}} =\frac{12.0}{4.0+2.0} =2.0\ \mathrm A \]
The conversion power is then
\[ \begin{aligned} P_{\mathrm{immediate}} &=(2.0)^2(6.0)\\ &=24.0\ \mathrm W \end{aligned} \]
The opposing torque magnitude becomes
\[ |\overline{\tau}_{\mathrm{em}}| =\frac{24.0}{20} =1.20\ \mathrm{N\,m} \]
But the driving torque is still only \(0.600\ \mathrm{N\,m}\).
The net torque therefore opposes rotation, and the generator begins to slow down.
Part b: Find the new steady speed
The internally generated RMS emf is proportional to angular speed.
Write
\[ E_{\mathrm{rms}}=k\omega \]
where \(k\) is the generator’s emf constant.
From the initial operating condition,
\[ k=\frac{12.0}{20} =0.600\ \mathrm{V\,s\,rad^{-1}} \]
At an unknown steady angular speed \(\omega_2\),
\[ E_2=0.600\omega_2 \]
The new total circuit resistance is \(6.0\ \Omega\), so
\[ I_2=\frac{0.600\omega_2}{6.0} =0.100\omega_2 \]
At steady speed, the electromagnetic counter-torque must again balance the applied \(0.600\ \mathrm{N\,m}\) driving torque.
Since conversion power is \(E_2I_2\),
\[ 0.600=\frac{E_2I_2}{\omega_2} \]
Substitute the expressions for emf and current:
\[ 0.600 =\frac{(0.600\omega_2) (0.100\omega_2)}{\omega_2} \]
For a non-zero steady speed, this simplifies to
\[ 0.600=0.0600\omega_2 \]
Therefore,
\[ \omega_2=10.0\ \mathrm{rad\,s^{-1}} \]
The new generated emf is
\[ E_2=(0.600)(10.0)=6.0\ \mathrm V \]
And the current is
\[ I_2=\frac{6.0}{6.0}=1.0\ \mathrm A \]
The generator settles at half its original speed, with the same RMS current as before switching.
Part c: Compare the power flows
Initially, the shaft mechanical input power is
\[ \begin{aligned} P_{\mathrm{shaft},1} &=\tau_{\mathrm{drive}}\omega_1\\ &=(0.600)(20.0)\\ &=12.0\ \mathrm W \end{aligned} \]
The original external resistor receives
\[ P_{\mathrm{load},1} =(1.0)^2(10.0) =10.0\ \mathrm W \]
The winding dissipates \(2.0\ \mathrm W\).
At the new steady speed,
\[ \begin{aligned} P_{\mathrm{shaft},2} &=(0.600)(10.0)\\ &=6.0\ \mathrm W \end{aligned} \]
The new resistor receives
\[ P_{\mathrm{load},2} =(1.0)^2(4.0) =4.0\ \mathrm W \]
The winding still dissipates
\[ P_{\mathrm{winding},2} =(1.0)^2(2.0) =2.0\ \mathrm W \]
Both steady-state energy balances are satisfied.
| Quantity | Initial state | Final state |
|---|---|---|
| External resistance | 10.0 Ω | 4.0 Ω |
| Angular speed | 20.0 rad/s | 10.0 rad/s |
| Generated RMS emf | 12.0 V | 6.0 V |
| RMS current | 1.0 A | 1.0 A |
| Driving torque | 0.600 N m | 0.600 N m |
| Mechanical input power | 12.0 W | 6.0 W |
| External load power | 10.0 W | 4.0 W |
| Winding heating | 2.0 W | 2.0 W |
Part d: Why this does not contradict Lenz’s law
Lenz’s law says the induced current’s magnetic effect opposes the change producing it. It does not say that lowering external resistance must always increase the final mechanical input power.
The smaller resistor initially causes more current and a stronger opposing torque. That is precisely why the generator slows down.
As the shaft slows, the rate of flux change decreases. The generated emf falls.
Eventually, the reduced emf lowers the current enough for the opposing torque to match the unchanged driving torque.
During the slowing process, some of the rotor’s initial rotational kinetic energy is also transferred into electrical energy and heat. The steady-state calculations do not describe that transient energy transfer.
At the final steady state, the generator converts less mechanical power because it is rotating more slowly under the same applied torque.
The tempting mistake is to apply the constant-speed rule to a constant-torque system.
Those are not equivalent constraints.
Part e: What if speed were held constant?
If the driving mechanism maintained \(20\ \mathrm{rad\,s^{-1}}\), the generated RMS emf would remain \(12.0\ \mathrm V\).
With the \(4.0\ \Omega\) resistor,
\[ I=\frac{12.0}{4.0+2.0}=2.0\ \mathrm A \]
The conversion power would be
\[ P_{\mathrm{conv}} =(2.0)^2(6.0) =24.0\ \mathrm W \]
The required average driving torque would then be
\[ \tau_{\mathrm{drive}} =\frac{24.0}{20.0} =1.20\ \mathrm{N\,m} \]
The constant-speed drive would need to double its applied torque, from \(0.600\ \mathrm{N\,m}\) to \(1.20\ \mathrm{N\,m}\).
It would also double its mechanical power input, from \(12.0\ \mathrm W\) to \(24.0\ \mathrm W\).
This is the central insight behind the entire investigation: increasing electrical load creates greater electromagnetic opposition at a given speed, but the final mechanical power depends on how the driving system responds.
10The next decision in a generator problem
When analysing a generator, first identify what is being held constant: rotational speed, driving torque, or available mechanical power.
Then follow the physical sequence: coil orientation determines changing flux, changing flux determines induced emf, circuit resistance and emf determine current, and current produces an opposing electromagnetic torque.
Finally, account for where the mechanical energy goes. Some reaches the electrical load, some heats the generator, and some is dissipated through other losses.
This approach also prepares you for more complex generators, where inductive loads introduce a phase difference between voltage and current. In those systems, multiplying RMS voltage by RMS current is not enough to determine real electrical power, but the underlying requirement remains: sustained electrical energy output must be supplied by an energy source driving the generator.