tutorgum
Try a Class

Why Reversing a DC Motor’s Supply Can Reverse Its Rotation

Learn why reversing the supply to a permanent-magnet DC motor reverses its torque, and why the shaft takes time to change direction. Explore how back EMF, winding resistance, and motor design affect current and rotation through worked examples and challenging HSC Physics questions.

A small DC motor is spinning clockwise. You swap the positive and negative supply leads. Will the motor immediately spin anticlockwise, or will it keep turning clockwise for a moment?

It keeps turning clockwise at first, but the electromagnetic torque reverses. The motor slows down, stops, and then accelerates in the opposite direction, provided the load allows it.

This happens in a brushed permanent-magnet DC motor because reversing the supply reverses the current through the armature while the magnetic field stays fixed. But there’s a complication: the spinning motor is also generating its own voltage, called back EMF. During reversal, that voltage can make the current much larger than you might expect.

And not every motor behaves this way. If reversing the supply also reverses the magnetic field, the motor’s torque might not reverse at all.

01Why swapping the supply leads reverses the torque

Start with the motor effect.

A current-carrying conductor experiences a force when it sits in a magnetic field. Reverse the current while keeping the field unchanged, and the force reverses.

Inside a simple brushed DC motor, the main parts are:

  • Two stationary permanent-magnet poles producing a magnetic field.
  • A rotating armature containing conducting windings.
  • Two stationary brushes supplying current to the rotating armature.
  • A split-ring or segmented commutator that changes the connections to the rotating windings as the shaft turns.

The magnetic forces on the armature produce a turning effect called torque.

The commutator ensures that, for a given supply polarity, the torque continues to act in the same rotational direction as the armature moves through successive positions.

Now reverse the two external supply leads.

The conventional current entering the armature reverses. The permanent magnets haven’t moved, so their magnetic field stays in the same direction.

The magnetic forces reverse, and so does the electromagnetic torque.

For a detailed method of determining individual force directions, see Motor-Effect Direction Rules for HSC Physics.

Torque reverses before rotation reverses

Think about a shopping trolley rolling forwards. If you suddenly push it backwards, it doesn’t immediately start travelling backwards. It must first lose its forward velocity.

A motor’s spinning rotor behaves similarly.

The reversed current produces torque opposing the existing rotation. The rotor still has angular momentum, so it continues moving forwards while slowing down.

The sequence is:

  1. The motor initially rotates clockwise under clockwise electromagnetic torque.
  2. The supply polarity reverses, making the electromagnetic torque anticlockwise.
  3. The rotor continues clockwise temporarily, but decelerates.
  4. Its angular velocity passes through zero.
  5. The anticlockwise torque accelerates it anticlockwise.

The trolley analogy explains the inertia, but it doesn’t explain what happens electrically. For that, we need back EMF.

02How an experiment could reveal what happens during reversal

A simple test would use a small brushed permanent-magnet DC motor connected to a low-voltage DC supply.

Mark one end of the motor shaft so you can identify its rotational direction.

With the shaft initially stationary, apply one supply polarity and observe which way the motor starts turning. Stop the motor completely, reverse the two leads, and start it again.

If the field remains fixed, you would expect opposite starting directions.

This comparison tests the link between supply polarity and starting torque. However, it cannot tell you what happens to the current when the supply is reversed while the motor is already spinning.

To investigate that, the experimental design needs more measurements.

A revised test: measure current and rotation together

Use a polarity-reversing switch connected between the DC supply and the motor.

Add three instruments:

  • A bidirectional ammeter in series with the motor, to measure current magnitude and direction.
  • A voltmeter across the motor terminals, to measure terminal voltage.
  • A rotational sensor on the shaft, to measure rotational speed and direction.

A double-pole, double-throw changeover switch can interchange the two supply connections without manually moving wires.

The motor’s magnetic poles remain fixed throughout.

What should the instruments reveal?

While the motor is running clockwise, it has a forward rotational speed and a corresponding induced voltage.

When the switch reverses the supply, the shaft cannot instantly reverse its velocity. Its induced voltage initially retains its original polarity.

The applied voltage and induced voltage now interact differently from when the motor was running normally.

This explains why measuring current is more revealing than simply watching the shaft.

The numerical readings developed below are illustrative model predictions, not measurements from an experiment.

03Why a running motor is not just a fixed resistor

A motor has copper windings, and copper has electrical resistance.

However, a rotating motor also generates an induced electromotive force because its conductors move through a magnetic field.

This is back EMF, also called counter-EMF.

During normal motoring, back EMF opposes the applied supply voltage. It reduces the voltage available to drive current through the winding resistance.

So a motor running quickly can draw relatively little current, even though its resistance hasn’t changed.

Use signed quantities when the motor reverses

We’ll choose a consistent sign convention.

Viewed from the marked end of the shaft:

  • Clockwise rotation and clockwise torque are positive.
  • Anticlockwise rotation and torque are negative.
  • Current entering labelled motor terminal A is positive.
  • Terminal voltage is \(V=V_A-V_B\).
  • Back EMF is positive for clockwise rotation in the fixed magnetic field.

For the simple brushed permanent-magnet motor model:

\[ V=IR+E \]

Rearranging:

\[ I=\frac{V-E}{R} \]

Here:

  • \(V\) is the signed motor terminal voltage in volts (V).
  • \(I\) is the signed armature current in amperes (A).
  • \(R\) is the effective armature winding resistance in ohms (\(\Omega\)).
  • \(E\) is the signed rotational back EMF in volts (V).

The resistance is treated as approximately constant during the calculation.

For a fixed magnetic field, the induced EMF is approximately proportional to angular velocity:

\[ E=k_{\mathrm e}\omega \]

Here, \(\omega\) is signed angular velocity in radians per second (\(\mathrm{rad\,s^{-1}}\)), and \(k_{\mathrm e}\) is a positive motor constant in volt seconds per radian (\(\mathrm{V\,s\,rad^{-1}}\)).

In the same simplified model, electromagnetic torque is proportional to current:

\[ \tau=k_{\mathrm t}I \]

Here, \(\tau\) is signed electromagnetic torque in newton metres (\(\mathrm{N\,m}\)), and \(k_{\mathrm t}\) is a positive torque constant in newton metres per ampere (\(\mathrm{N\,m\,A^{-1}}\)).

These two relationships give us an important distinction:

  • The direction of electromagnetic torque depends on current direction.
  • The polarity of the generated EMF depends on rotational direction, for a fixed magnetic field.

They don’t have to reverse at the same instant.

For more on why the resistance and induced EMF must be treated separately, see Back EMF vs Resistive Voltage Drop: HSC Physics Guide.

Worked example: What happens to current during a reversal?

A brushed permanent-magnet DC motor operates from a \(9.0\,\mathrm{V}\) supply. Its winding resistance is \(3.0\,\Omega\).

Initially, the motor rotates clockwise and produces a back EMF of \(+6.0\,\mathrm{V}\).

The supply is reversed to \(-9.0\,\mathrm{V}\).

Calculate the current:

  • Before reversal.
  • Shortly after reversal, once the brief electrical transient has settled but before the shaft speed changes appreciably.
  • When the motor reaches zero rotational speed.
  • When it later rotates anticlockwise at the same speed magnitude as initially.

Assume constant winding resistance, a fixed magnetic field, and no supply current limiting.

Step 1

Using \(I=(V-E)/R\):

\[ I=\frac{9.0-6.0}{3.0} =+1.0\,\mathrm{A} \]

The positive current produces clockwise electromagnetic torque.

Step 2

The supply voltage becomes \(-9.0\,\mathrm{V}\).

But the motor is still rotating clockwise at approximately its original speed, so its back EMF remains \(+6.0\,\mathrm{V}\).

\[ I=\frac{-9.0-6.0}{3.0} =-5.0\,\mathrm{A} \]

The current is now negative, producing anticlockwise torque.

Notice that its magnitude is five times the original current.

The reversed supply and the existing forward-rotation EMF both contribute to driving current in the negative direction.

Step 3

At zero angular velocity, the rotational back EMF is zero.

\[ I=\frac{-9.0-0}{3.0} =-3.0\,\mathrm{A} \]

The current is still negative, so the electromagnetic torque remains anticlockwise.

The motor can now start accelerating in the reverse direction.

Step 4

If the rotor eventually reaches the same speed magnitude in the opposite direction, its back EMF is \(-6.0\,\mathrm{V}\).

\[ I=\frac{-9.0-(-6.0)}{3.0} =-1.0\,\mathrm{A} \]

The current magnitude has fallen again as the motor speeds up anticlockwise.

The negative current continues to produce anticlockwise driving torque.

What the reversal measurements would show

Motor state\(V\) (V)\(E\) (V)\(I\) (A)
Running clockwise+9.0+6.0+1.0
Supply reversed, rotor still clockwise−9.0+6.0−5.0
Rotor at zero speed−9.00−3.0
Running anticlockwise at equal speed magnitude−9.0−6.0−1.0

Illustrative ideal-model values, not recorded experimental results. The second row represents the period after the electrical transient but before substantial mechanical slowing. The final row assumes the motor can reach the stated reverse speed.

Two results are especially important.

First, reversing the voltage does not simply change \(+1.0\,\mathrm{A}\) to \(-1.0\,\mathrm{A}\) while the shaft is still rotating forwards.

Second, the largest current magnitude in this sequence occurs during braking, not at zero speed.

This braking method, in which the supply drives torque against the existing rotation, is called plugging.

It can produce damaging currents in a real motor. The calculation describes an ideal electrical model, not a recommended procedure for switching a running motor directly across a full-voltage supply.

04Where does the energy go when the motor is braking?

A reversing motor does more than change current direction.

While its torque opposes its rotation, it removes mechanical energy from the rotating shaft.

At the same time, electrical energy may still be supplied by the battery.

We can test the energy balance using:

\[ VI=I^2R+EI \]

The terms represent:

  • \(VI\): signed electrical power entering the motor terminals, in watts (W).
  • \(I^2R\): power converted into heat in the winding resistance, in watts.
  • \(EI\): signed electromagnetic power transferred to the shaft, in watts.

Positive \(EI\) means electromagnetic torque is supplying mechanical power to the shaft.

Negative \(EI\) means mechanical power is being taken from the rotating shaft.

Worked example: Can a reversed motor draw power from two sources?

A brushed permanent-magnet DC motor has a winding resistance of \(2.0\,\Omega\).

It is rotating clockwise with a back EMF of \(+4.0\,\mathrm{V}\) when its supply changes from \(+8.0\,\mathrm{V}\) to \(-8.0\,\mathrm{V}\).

Assume that its speed remains approximately unchanged while the electrical current settles.

Calculate the new current, the electrical power supplied at the motor terminals, the winding heating power, and the electromagnetic mechanical power.

Step 1

\[ I=\frac{-8.0-4.0}{2.0} =-6.0\,\mathrm{A} \]

The electromagnetic torque is now anticlockwise, even though the shaft is still rotating clockwise.

Step 2

\[ P_{\mathrm{in}}=VI =(-8.0)(-6.0) =48\,\mathrm{W} \]

The positive result means the external electrical supply is delivering \(48\,\mathrm{W}\) to the motor circuit.

Step 3

\[ P_R=I^2R =(-6.0)^2(2.0) =72\,\mathrm{W} \]

The winding resistance is converting \(72\,\mathrm{W}\) into heat.

How can the winding receive only \(48\,\mathrm{W}\) from the supply but dissipate \(72\,\mathrm{W}\)?

Step 4

\[ P_{\mathrm{em}}=EI =(4.0)(-6.0) =-24\,\mathrm{W} \]

The negative result means the electromagnetic interaction is removing mechanical energy from the rotating shaft at a rate of \(24\,\mathrm{W}\).

The energy balance is:

\[ 48\,\mathrm{W}+24\,\mathrm{W} =72\,\mathrm{W} \]

The electrical supply contributes \(48\,\mathrm{W}\), and the rotating shaft contributes another \(24\,\mathrm{W}\). Both contributions become winding heat in this simplified calculation.

This is why reversing a running motor’s supply can be very different from starting it from rest.

The stored rotational energy and the external electrical supply can contribute to the same large current and heating.

05The contrasting case: when reversing the supply does not reverse the motor

So far, we’ve assumed that permanent magnets produce a fixed magnetic field.

What happens if the motor uses an electromagnet instead?

Consider a series-wound DC motor.

Its field winding and armature winding are connected in series, so the same current passes through both.

Reversing the external supply reverses the current in both windings.

That changes two things simultaneously:

  1. The current direction in the armature reverses.
  2. The magnetic field produced by the field winding also reverses.

The electromagnetic torque depends on both quantities.

For a simplified wound-field motor:

\[ \tau\propto\Phi I_a \]

Here, \(\Phi\) is the signed magnetic flux associated with the field winding, and \(I_a\) is the signed armature current.

If the supply reverses both the field flux and armature current, their product retains its original sign:

\[ (-\Phi)(-I_a)=\Phi I_a \]

The torque therefore remains in the original direction, under the idealised assumptions.

This also changes how we interpret back EMF.

For a permanent-magnet motor, the field remains fixed, so the induced EMF changes sign when the direction of rotation changes.

For a series-wound motor, induced EMF depends on both field flux and rotational velocity:

\[ E\propto\Phi\omega \]

If the field reverses while the rotor is still moving in the original direction, the induced EMF can reverse sign even before the rotor changes direction.

That is why we must identify the motor’s magnetic-field arrangement before using a polarity reversal to predict rotation.

How to reverse a series-wound motor

To reverse its electromagnetic torque, reverse the armature current relative to the field direction.

That can be achieved by reversing the connections to the armature alone, or to the field winding alone, while leaving their relative polarity changed.

Simply reversing both external supply terminals on an ordinary two-terminal series-wound motor reverses both currents and does not produce the same effect.

The same principle explains why reversing both the field and armature currents of a shunt-wound DC motor need not reverse its torque.

Other motor systems, including electronically controlled brushless motors, have different connection and control arrangements. The two-wire reversal rule should not be applied to them automatically.

06What you can and cannot predict from reversed polarity

For a brushed DC motor, use this reasoning sequence.

Identify the magnetic field first. If permanent magnets or a separately maintained field keep the field direction fixed, reversing armature current reverses electromagnetic torque. If both field and armature reverse, the torque may retain its direction.

Separate torque from rotation. Torque determines angular acceleration, not instantaneous angular velocity. A motor can be rotating clockwise while experiencing anticlockwise torque.

Account for the back EMF. The shaft may still be generating an EMF of its original sign when the supply is reversed. Use signed values in \(V=IR+E\), rather than treating the motor as a fixed resistor.

Consider whether the load permits reversal. Reverse torque does not guarantee reverse rotation. A blocked shaft, a strong external driving force, or an unsuitable load can prevent the expected motion.

The model also has limitations. Real windings have inductance, so current cannot jump instantaneously when the voltage changes. The equation \(V=IR+E\) describes the electrical behaviour after that brief transient, when the current is changing slowly enough for the inductive voltage to be neglected.

Winding resistance changes with temperature, brushes introduce additional voltage losses, and real motors have friction and operating limits.

For the calculations here, we’ve assumed that the electrical transient is short compared with the time taken for the rotor to change speed appreciably. A current-limited supply would reduce the large reversal currents predicted by the ideal model.

07Questions and solutions

Question 1

A brushed permanent-magnet DC motor has a winding resistance of \(2.0\,\Omega\).

The shaft is held stationary, so its rotational back EMF is zero.

A \(+6.0\,\mathrm{V}\) supply is connected, with positive current defined as producing clockwise torque.

The supply polarity is then reversed to \(-6.0\,\mathrm{V}\), while the shaft remains stationary.

Assume the electrical current has settled after each connection.

Calculate the current in each case and explain how the direction of the electromagnetic torque changes. Predict the initial direction of rotation if the shaft is released.

Solution 1

The current changes from \(+3.0\,\mathrm{A}\) to \(-3.0\,\mathrm{A}\), reversing the electromagnetic torque from clockwise to anticlockwise.

Because the shaft is stationary, \(E=0\).

For the original connection:

\[ I=\frac{6.0-0}{2.0} =+3.0\,\mathrm{A} \]

For the reversed connection:

\[ I=\frac{-6.0-0}{2.0} =-3.0\,\mathrm{A} \]

The magnetic field remains fixed because the motor uses permanent magnets.

Reversing armature current therefore reverses the magnetic forces responsible for torque.

When released, the motor initially accelerates clockwise under the first connection and anticlockwise under the second, assuming the electromagnetic torque overcomes the mechanical load.

The important detail is that this calculation applies to a stationary rotor after the electrical transient. A rotating motor would also produce back EMF, changing the calculated current.

Question 2

Two identical brushed permanent-magnet DC motors, A and B, are connected separately to \(+10.0\,\mathrm{V}\) supplies.

Each has a winding resistance of \(2.0\,\Omega\).

Both are initially rotating clockwise, but they drive different mechanical loads.

Motor A draws \(+1.0\,\mathrm{A}\), while motor B draws \(+3.0\,\mathrm{A}\).

Their supplies are simultaneously reversed to \(-10.0\,\mathrm{V}\).

Assume the electrical transients have settled but neither motor has changed rotational speed appreciably.

Determine:

a. The original back EMF of each motor and their initial speed ratio.

b. The current in each motor just after reversal.

c. Which motor experiences the greater magnitude of electromagnetic braking torque.

d. Whether the results establish which motor will stop first.

Solution 2

Motor A has the larger initial back EMF and experiences the greater braking-current magnitude after reversal. However, the information is insufficient to establish which motor stops first.

Part a: Original back EMFs and speed ratio

Rearrange the motor voltage equation:

\[ E=V-IR \]

For motor A:

\[ E_A=10.0-(1.0)(2.0) =+8.0\,\mathrm{V} \]

For motor B:

\[ E_B=10.0-(3.0)(2.0) =+4.0\,\mathrm{V} \]

The motors are identical and have the same fixed magnetic field, so \(E=k_{\mathrm e}\omega\) uses the same constant for both.

Thus:

\[ \frac{\omega_A}{\omega_B} =\frac{8.0}{4.0} =2 \]

Motor A initially rotates twice as fast as motor B.

Part b: Currents after reversal

The rotor speeds have not yet changed appreciably, so their original back EMFs remain positive.

For motor A:

\[ I_A=\frac{-10.0-8.0}{2.0} =-9.0\,\mathrm{A} \]

For motor B:

\[ I_B=\frac{-10.0-4.0}{2.0} =-7.0\,\mathrm{A} \]

Part c: Braking torque

Motor A experiences the greater braking-torque magnitude.

For identical fixed-field motors, \(\tau=k_{\mathrm t}I\). Motor A has a current magnitude of \(9.0\,\mathrm{A}\), compared with \(7.0\,\mathrm{A}\) for B.

Both torques are anticlockwise, opposing the existing clockwise rotation.

The tempting prediction is that motor B should have the greater current because it was drawing more current under its original heavier load.

But after reversal, motor A’s larger forward back EMF contributes to a larger negative current.

Part d: Which motor stops first?

We cannot determine the stopping order from these current readings alone.

Motor A experiences greater electromagnetic braking torque, but it also starts at twice the angular speed of B.

The changing motor currents, opposing load torques, and rotational dynamics must all be considered. We haven’t been given enough information about how the mechanical loads behave as the motors slow.

A larger instantaneous braking torque does not, by itself, establish the shorter stopping time.

Question 3

Two brushed DC motors are initially rotating clockwise while driving suitable mechanical loads.

Motor P uses permanent magnets to produce its magnetic field.

Motor S uses a series field winding connected electrically in series with its armature.

Their external supply polarities are reversed.

Assume both motors have symmetric construction, the series field follows the direction of its current, and the electrical transients have settled while the shafts are still moving clockwise.

a. Explain the resulting electromagnetic torque direction in each motor.

b. A student argues that the back EMF of both motors must remain positive because both shafts are still rotating clockwise. Is this correct?

c. Explain how the electrical connections of motor S could be changed to reverse its electromagnetic torque.

Solution 3

Motor P develops anticlockwise electromagnetic torque, while motor S continues to develop clockwise electromagnetic torque under the stated ideal assumptions. The student’s back-EMF argument is correct for P but not for S.

Part a: Torque directions

In motor P, the supply reversal changes armature current direction but does not change the permanent-magnet field.

The motor-effect forces reverse, producing anticlockwise torque.

In motor S, reversing the external supply reverses both the armature current and the series field current.

Using the torque relationship:

\[ \tau\propto\Phi I_a \]

Both \(\Phi\) and \(I_a\) reverse, leaving the sign of their product unchanged.

Motor S therefore retains clockwise electromagnetic torque after the field and current have settled.

This doesn’t mean every real motor would maintain exactly the same torque magnitude through a switching transient. The conclusion concerns its eventual torque direction under the simplified symmetric model.

Part b: Back EMF

For motor P, the induced EMF remains positive while the shaft continues rotating clockwise because the permanent-magnet field remains fixed.

For motor S, the field reverses when its field-winding current reverses.

Since:

\[ E\propto\Phi\omega \]

reversing \(\Phi\) changes the sign of \(E\) even if \(\omega\) remains positive.

The student’s mistake is treating rotational direction as the only factor determining the back-EMF polarity. That is true only when the field direction is fixed.

Part c: Reversing motor S

Reverse the connection to the armature relative to the field winding, or reverse the field-winding connection relative to the armature.

Either change reverses one factor in the torque relationship while leaving the other unchanged.

Simply swapping the two external terminals reverses both factors, which is why it does not achieve the same result.

Question 4

A brushed permanent-magnet DC motor is connected to a DC supply through an external series resistor of \(2.0\,\Omega\).

The motor itself has a winding resistance of \(1.0\,\Omega\).

The positive current reference direction is through the external resistor into motor terminal A. The motor terminal voltage is measured as \(V_m=V_A-V_B\).

Initially, the applied supply voltage across the entire series circuit is \(+9.0\,\mathrm{V}\), and the motor rotates clockwise with a back EMF of \(+6.0\,\mathrm{V}\).

A reversing switch changes the applied supply to \(-9.0\,\mathrm{V}\).

Assume the electrical transient has settled while the shaft is still rotating clockwise with approximately the original speed.

a. Calculate the current and motor terminal voltage before reversal.

b. Calculate the current and motor terminal voltage after reversal.

c. A student sees that the motor terminal voltmeter still reads a positive voltage and concludes that the reversing switch has failed. Explain why this conclusion is incorrect.

d. Determine the motor terminal voltage if the shaft subsequently reaches zero speed while the \(-9.0\,\mathrm{V}\) supply remains connected.

Solution 4

The motor terminal voltage is \(+7.0\,\mathrm{V}\) before reversal and remains positive at \(+1.0\,\mathrm{V}\) shortly after reversal, even though the applied supply has become \(-9.0\,\mathrm{V}\). This does not indicate a wiring fault.

Part a: Before reversal

The total series resistance is:

\[ R_{\mathrm{total}}=2.0+1.0 =3.0\,\Omega \]

The supply must overcome both resistive voltage drops and the motor’s induced EMF.

\[ I=\frac{9.0-6.0}{3.0} =+1.0\,\mathrm{A} \]

The terminal voltage across the motor is:

\[ V_m=E+IR_m \]

where \(R_m=1.0\,\Omega\) is the motor’s winding resistance.

\[ V_m=6.0+(1.0)(1.0) =+7.0\,\mathrm{V} \]

Part b: After reversal

The applied supply voltage is now \(-9.0\,\mathrm{V}\).

The motor remains rotating clockwise, so \(E=+6.0\,\mathrm{V}\).

\[ I=\frac{-9.0-6.0}{3.0} =-5.0\,\mathrm{A} \]

The motor terminal voltage becomes:

\[ V_m=6.0+(-5.0)(1.0) =+1.0\,\mathrm{V} \]

The electromagnetic torque is anticlockwise because the current is negative.

Part c: Why is motor voltage still positive?

The source has reversed, but the rotating motor still generates a positive back EMF.

The large negative current also produces a voltage drop across the external resistor.

Applying Kirchhoff’s voltage law to the entire circuit:

\[ V_s=IR_s+V_m \]

Substitute the values:

\[ -9.0=(-5.0)(2.0)+1.0 \]

\[ -9.0=-10.0+1.0 \]

The voltage balance is correct.

The external resistor has a signed drop of \(-10.0\,\mathrm{V}\), leaving the motor terminal voltage at \(+1.0\,\mathrm{V}\).

In fact, at this moment the motor is delivering electrical power out of its terminals:

\[ P_m=V_mI=(1.0)(-5.0) =-5.0\,\mathrm{W} \]

The motor is acting as a generator at its terminals while its electromagnetic torque brakes the clockwise rotation.

That is possible because the rotating shaft is supplying mechanical energy.

Part d: At zero speed

When the rotor stops, \(E=0\).

The circuit current is:

\[ I=\frac{-9.0}{3.0} =-3.0\,\mathrm{A} \]

The motor terminal voltage becomes:

\[ V_m=0+(-3.0)(1.0) =-3.0\,\mathrm{V} \]

The voltage has changed sign because the positive rotational EMF has disappeared.

The mistake would be assuming that the polarity of the external supply alone determines the voltage measured across every component in a circuit containing a rotating motor.

Question 5

A brushed permanent-magnet DC motor is connected to a reversible electrical supply.

Its magnetic field is fixed, and its winding resistance is \(2.0\,\Omega\).

Clockwise rotation, clockwise electromagnetic torque, and current entering terminal A are defined as positive.

The motor is connected to a large flywheel and, when required, an auxiliary mechanical drive that can force the shaft to rotate at a chosen speed.

The electrical supply is fixed at \(-8.0\,\mathrm{V}\) throughout the following three observations.

The measurements are illustrative and are taken after the electrical transients have settled.

  • Observation A: Shortly after reversal from clockwise operation, the motor current is \(-6.0\,\mathrm{A}\).
  • Observation B: Later, the motor current is \(-2.0\,\mathrm{A}\).
  • Observation C: The auxiliary drive is engaged and forces the shaft to rotate faster anticlockwise. The motor current becomes \(+1.0\,\mathrm{A}\).

Assume constant motor constants, negligible mechanical friction, and no significant inductive voltage during the observations.

a. Determine the direction of rotation and electromagnetic torque at each observation.

b. For each observation, calculate the electrical power exchanged with the supply, winding heating power, and electromagnetic mechanical power.

c. Explain how observation C can have positive current even though the applied voltage is negative.

d. Which of the three observations could be maintained at constant speed against a suitable passive mechanical load, without an auxiliary mechanical drive? Explain using torque and energy conservation.

A student proposes that positive current in observation C proves the motor has returned to clockwise rotation. Evaluate that explanation.

Solution 5

At A, the motor rotates clockwise but develops anticlockwise braking torque. At B, both rotation and electromagnetic torque are anticlockwise. At C, the motor still rotates anticlockwise, but its electromagnetic torque has become clockwise, and it delivers electrical power back to the supply.

The key is that current direction determines electromagnetic torque, while the induced EMF determines rotational direction when the magnetic field is fixed.

Part a: Infer rotation and torque

Start with:

\[ E=V-IR \]

For observation A:

\[ E_A=-8.0-(-6.0)(2.0) =+4.0\,\mathrm{V} \]

The positive EMF tells us the shaft is rotating clockwise.

However, the negative current produces anticlockwise torque.

The motor is braking clockwise rotation.

For observation B:

\[ E_B=-8.0-(-2.0)(2.0) =-4.0\,\mathrm{V} \]

The negative EMF tells us the shaft is rotating anticlockwise.

The negative current also produces anticlockwise torque.

The motor is driving the shaft in its current direction of rotation.

For observation C:

\[ E_C=-8.0-(1.0)(2.0) =-10.0\,\mathrm{V} \]

The back EMF is still negative, so the shaft is rotating anticlockwise.

But the current is now positive, producing clockwise electromagnetic torque.

Thus, the motor is resisting the imposed anticlockwise rotation.

This is the crucial result: reversing the current does not necessarily mean the rotor has reversed its direction of motion.

Part b: Calculate the power flows

Use:

\[ P_{\mathrm{in}}=VI \]

\[ P_R=I^2R \]

\[ P_{\mathrm{em}}=EI \]

All powers are measured in watts.

For observation A:

\[ \begin{aligned} P_{\mathrm{in}}&=(-8.0)(-6.0)\\ &=+48\,\mathrm{W}\\ P_R&=(-6.0)^2(2.0)\\ &=72\,\mathrm{W}\\ P_{\mathrm{em}}&=(4.0)(-6.0)\\ &=-24\,\mathrm{W} \end{aligned} \]

The electrical supply provides \(48\,\mathrm{W}\).

The shaft loses mechanical energy through electromagnetic braking at \(24\,\mathrm{W}\).

Together, those contributions account for the \(72\,\mathrm{W}\) of winding heating.

For observation B:

\[ \begin{aligned} P_{\mathrm{in}}&=(-8.0)(-2.0)\\ &=+16\,\mathrm{W}\\ P_R&=(-2.0)^2(2.0)\\ &=8\,\mathrm{W}\\ P_{\mathrm{em}}&=(-4.0)(-2.0)\\ &=+8\,\mathrm{W} \end{aligned} \]

The supply provides \(16\,\mathrm{W}\).

Half becomes winding heat, and the other \(8\,\mathrm{W}\) becomes electromagnetic mechanical power delivered to the shaft.

The motor is now operating in the usual motoring sense, but anticlockwise.

For observation C:

\[ \begin{aligned} P_{\mathrm{in}}&=(-8.0)(+1.0)\\ &=-8\,\mathrm{W}\\ P_R&=(1.0)^2(2.0)\\ &=2\,\mathrm{W}\\ P_{\mathrm{em}}&=(-10.0)(+1.0)\\ &=-10\,\mathrm{W} \end{aligned} \]

The negative electrical input means the motor sends \(8\,\mathrm{W}\) into the external electrical supply.

The auxiliary mechanical drive provides \(10\,\mathrm{W}\) through the shaft.

Of this, \(2\,\mathrm{W}\) becomes winding heat, while \(8\,\mathrm{W}\) is returned electrically to the supply.

The motor is operating as a generator.

Part c: Why has current become positive?

At observation C, the motor is rotating anticlockwise sufficiently quickly to produce a back EMF of \(-10.0\,\mathrm{V}\).

The external supply is only \(-8.0\,\mathrm{V}\).

Substituting into the current equation:

\[ I=\frac{-8.0-(-10.0)}{2.0} =+1.0\,\mathrm{A} \]

The generated EMF has a greater magnitude than the externally applied voltage.

That changes the direction of current.

It also changes the energy transfer: the externally driven shaft is now generating electrical power that can flow back towards the supply.

The tempting interpretation is that a negative supply must always cause negative current and anticlockwise torque.

But the direction of current depends on the difference \(V-E\), not on \(V\) alone.

Part d: Which observation can be steady against a passive load?

Only observation B could be maintained at constant speed against a suitable passive mechanical load without another mechanical drive.

At B, the motor’s torque and angular velocity are both anticlockwise. The motor supplies positive mechanical power to the shaft.

A resisting load could absorb that \(8\,\mathrm{W}\), with the opposing torques balancing so the speed remains constant.

At A, the motor rotates clockwise while its electromagnetic torque acts anticlockwise. The motor is removing rotational energy. A passive load would also resist the motion, so it could not maintain that clockwise speed without some external source of mechanical power.

At C, the motor rotates anticlockwise while its electromagnetic torque acts clockwise.

The motor is again removing mechanical energy from the shaft. The auxiliary drive must supply that energy if the speed is to remain constant.

Without the auxiliary drive, the shaft could temporarily continue anticlockwise because of its stored rotational energy, but the electromagnetic torque would slow it down. It could not remain in the same generating state indefinitely against a passive load alone.

Evaluating the student’s explanation

The student’s conclusion is incorrect.

Positive current at C means clockwise electromagnetic torque, not clockwise rotation.

The induced EMF calculated from the measured voltage and current is \(-10.0\,\mathrm{V}\). With the permanent-magnet field fixed, that establishes anticlockwise rotation.

The result exposes a distinction that ordinary motor-direction questions can hide:

An electric machine can rotate in one direction while its electromagnetic torque acts in the opposite direction. Depending on the relationship between the applied voltage and generated EMF, it may be slowing down, absorbing mechanical power, or returning electrical energy to a supply.

08The next useful distinction: motor or generator?

Reversing a brushed permanent-magnet motor’s supply reverses the electromagnetic torque because its magnetic field stays fixed while the armature current changes direction.

But predicting what happens next requires more than knowing the supply polarity.

You need to distinguish three things: the direction the shaft is moving, the direction of electromagnetic torque, and the current produced by the difference between supply voltage and back EMF.

That same reasoning explains both plug braking and generator operation.

Once you can use \(V=IR+E\) with consistent signs, you can recognise when electrical energy is driving rotation, when the motor is braking a rotating load, and when a mechanically driven motor is returning energy to the electrical circuit.