Quantum Superposition: Coherence, Phase, and Two-State Systems
Explore how quantum superposition differs from ordinary uncertainty using two-state systems, atomic energy levels, and photon interference. Learn how relative phase, decoherence, and measurement reveal the difference between coherent quantum states and classical mixtures.
A photon enters a balanced interferometer. The first beam splitter gives it two possible paths, and a second beam splitter brings those paths back together. If each photon simply travelled along one path, but we didn’t know which, we’d expect half the photons to reach each detector. Yet, when the paths remain coherent and have the correct relative phase, an ideal experiment can send every photon to one detector and none to the other.
How can two situations with identical 50:50 path probabilities produce completely different results?
The answer is quantum superposition. It introduces a crucial distinction between a system having several possible measurement outcomes and a system being in a coherent combination of quantum states.
Syllabus note: Quantum superposition, as developed in this article, goes beyond the required 2025 NSW HSC Physics syllabus. The Year 12 Matter, energy and the cosmos material on the stationary energy-level model is the assumed starting point, not an assessment requirement for this extension. NESA schedules implementation of the new syllabus for Year 12 from Term 4 2027, with the first HSC examination in 2028.
Due to technical limitations, this figure may display incorrectly or contain inaccuracies. Please check key details against your course materials.
Before explaining the result, make a prediction. If the photon has a 50% probability of taking the upper path and a 50% probability of taking the lower path, should the output detectors necessarily receive equal numbers of photons?
No. The 50:50 probabilities describe measurements made before the paths are recombined. They do not tell us everything about the quantum state. In particular, they do not tell us whether the two alternatives have a well-defined relative phase.
That missing information is what makes superposition different from ordinary uncertainty.
01The atomic model that leads here
To understand why this idea matters, start with the atomic model from Year 12 Physics.
Rutherford’s nuclear model established that an atom contains a tiny, positively charged nucleus, with electrons outside it. This explained the results of the gold foil experiment, but it created a serious problem.
If an electron travelled around the nucleus in a circular orbit, its velocity would constantly change direction. Even if its speed stayed constant, it would still be accelerating.
Classical electromagnetic theory predicts that an accelerating electric charge radiates electromagnetic energy.
So what would happen to the electron?
It would lose energy, move into a smaller orbit, and continue losing energy. Eventually, it would spiral into the nucleus.
Atoms would be unstable. Clearly, this does not match the behaviour of ordinary matter.
There was another problem. As the electron lost energy continuously, the classical model predicted radiation across a continuous range of frequencies. Experiments instead showed that atoms produce distinctive line emission spectra.
The stationary energy-level model
Bohr’s model addressed these problems by combining classical physics with quantum rules.
It retained some familiar classical ideas:
- A small, positively charged nucleus sits at the centre.
- The electron is attracted to the nucleus by electrostatic force.
- Classical mechanics helps describe the electron’s motion in the allowed orbits.
However, it introduced new quantum restrictions:
- Only certain electron orbits and energies are allowed.
- An electron in an allowed stationary state does not continuously radiate energy.
- Electrons can transition between allowed energy states.
- Radiation is emitted or absorbed only during these transitions.
The important change is that the electron cannot simply occupy any orbit with any energy.
Its energy is restricted to particular values.
This produces discrete energy levels, which explain why atoms emit and absorb particular photon frequencies rather than a continuous range.
For an emission transition, the photon receives energy equal to the difference between the initial and final atomic energy levels:
\[ \Delta E=E_i-E_f=hf=\frac{hc}{\lambda} \]
Here:
- \(\Delta E\) is the energy lost by the atom, in joules (J).
- \(E_i\) is the initial atomic energy.
- \(E_f\) is the final atomic energy.
- \(h\) is Planck’s constant, \(6.63\times10^{-34}\ \mathrm{J\,s}\).
- \(f\) is the emitted photon’s frequency, in hertz (Hz).
- \(c\) is the speed of light, approximately \(3.00\times10^8\ \mathrm{m\,s^{-1}}\).
- \(\lambda\) is the photon’s wavelength, in metres (m).
The model is called semi-classical because it combines classical descriptions of electron motion with quantum restrictions on allowed states and transitions.
It was a major improvement, but it was not the final atomic model. The Bohr picture works particularly well for hydrogen and hydrogen-like one-electron ions. It cannot accurately describe the full behaviour of multi-electron atoms.
Modern quantum mechanics replaces definite circular electron orbits with quantum states and probability distributions.
This is where superposition becomes important.
02Two possible states do not necessarily mean uncertainty
Consider a simple quantum system with exactly two possible states.
Our interferometer provides a useful example. The photon has two possible path states:
- \(|L\rangle\): the photon is in the left-hand path.
- \(|R\rangle\): the photon is in the right-hand path.
The vertical bars and angle brackets are standard quantum notation. You can read \(|L\rangle\) as the state labelled L.
These two states form a basis: a set of reference states used to describe the system.
There are two fundamentally different ways to describe a 50:50 distribution between them.
Case 1: A classical mixture
Imagine that every photon has already taken one definite path.
Half travel through L, and half travel through R. We simply don’t know which path any particular photon has taken.
This is ordinary uncertainty about a classical state.
The photon is either in L or R, and our uncertainty comes from incomplete information.
If we measure the path, we obtain:
\[ P(L)=0.5 \]
\[ P(R)=0.5 \]
Here, \(P\) represents probability.
Case 2: A coherent quantum superposition
Quantum mechanics allows a different description.
Instead of saying the photon is definitely in one path or the other, we can describe its state as a combination of both:
\[ |\psi\rangle= \frac{1}{\sqrt{2}} \left(|L\rangle+|R\rangle\right) \]
The symbol \(|\psi\rangle\) represents the complete quantum state.
This is an equal coherent superposition of the two path states.
The coefficients in front of the states are called probability amplitudes. They are not probabilities themselves.
To calculate the probability of measuring a particular state, we take the squared magnitude of its amplitude.
For example:
\[ P(L)=\left|\frac{1}{\sqrt{2}}\right|^2 =\frac12 \]
Similarly:
\[ P(R)=\frac12 \]
Notice something important.
A coherent superposition and a 50:50 classical mixture produce exactly the same probabilities when we measure the path.
If we only measure L or R, we cannot distinguish them.
So where is the difference?
It appears when we bring the two alternatives back together.
The importance of relative phase
A more general equal-amplitude superposition is:
\[ |\psi\rangle= \frac{1}{\sqrt{2}} \left(|L\rangle+e^{i\phi}|R\rangle\right) \]
The new symbol \(\phi\) represents the relative phase between the two probability amplitudes.
The symbol \(i\) is the imaginary unit, satisfying \(i^2=-1\). The factor \(e^{i\phi}\) is a mathematical way of representing a phase angle.
You do not need advanced complex-number calculations to follow the physics. The important idea is that the two amplitudes have a phase relationship that can affect the outcome when they are combined.
In a balanced interferometer, the second beam splitter recombines the paths.
For a particular calibration of the beam splitter, the output probabilities are:
\[ P(D_+)=\cos^2\left(\frac{\phi}{2}\right) \]
\[ P(D_-)=\sin^2\left(\frac{\phi}{2}\right) \]
Here, \(D_+\) and \(D_-\) represent the two output detectors.
These equations assume equal path amplitudes, ideal beam splitters, and no loss of coherence.
Consider three phase settings:
| Relative phase | Probability at D+ | Probability at D− |
|---|---|---|
| \(0^\circ\) | 100% | 0% |
| \(90^\circ\) | 50% | 50% |
| \(180^\circ\) | 0% | 100% |
At zero phase difference, the amplitudes reinforce each other at D+ and cancel at D−.
At \(180^\circ\), the situation reverses.
This is the key feature of coherent superposition: the relative phase affects the result of a measurement.
For a classical mixture, the two path probabilities simply add. Each path contributes a 50:50 distribution at the second beam splitter, giving:
\[ P(D_+)=P(D_-)=0.5 \]
regardless of the phase setting.
The mixture cannot produce the phase-dependent interference predicted by a coherent superposition.
The mathematics resembles classical wave interference, where two waves reinforce or cancel depending on their relative phase. You can revise that familiar idea in Wave Superposition and Interference for HSC Physics.
However, there is an important difference. In a single-photon experiment, each detection is one individual event. The interference appears in the statistical distribution of many events, not as a photon being detected in two halves.
Worked example: Predicting the output of a quantum interferometer
A single-photon source sends 800 photons, one at a time, through a balanced interferometer. The photons are prepared in an equal coherent superposition of the two paths.
The relative phase at the second beam splitter is \(120^\circ\).
Calculate the expected number of photons detected at D+ and D−. Compare this with the result expected from an equal classical mixture.
Step 1
For a coherent superposition:
\[ P(D_+)=\cos^2\left(\frac{\phi}{2}\right) \]
\[ P(D_-)=\sin^2\left(\frac{\phi}{2}\right) \]
Step 2
Since \(\phi=120^\circ\):
\[ P(D_+)=\cos^2(60^\circ) \]
\[ P(D_+)=0.25 \]
Similarly:
\[ P(D_-)=\sin^2(60^\circ) \]
\[ P(D_-)=0.75 \]
Step 3
At D+:
\[ N_+=800\times0.25=200 \]
At D−:
\[ N_-=800\times0.75=600 \]
The coherent superposition therefore predicts approximately 200 detections at D+ and 600 at D−.
These are expected counts. An actual experiment with a finite number of photons can fluctuate around them.
Step 4
For an equal mixture, each path contributes equally to both detectors.
Therefore:
\[ N_+=800\times0.5=400 \]
\[ N_-=800\times0.5=400 \]
The mixture predicts 400 detections at each detector.
The difference is not in the initial path probabilities. Both preparations give 50:50 probabilities when the paths are measured separately.
The difference is whether the alternatives retain a coherent relative phase when they are recombined.
03How do we distinguish superposition from ordinary uncertainty?
The interferometer demonstrates an important general principle.
Two quantum preparations can produce identical results in one measurement basis but different results in another.
This is easiest to see using a two-state atom.
Consider an atom with two allowed energy states:
- \(|g\rangle\): the ground state, with energy \(E_g\).
- \(|e\rangle\): the excited state, with energy \(E_e\).
These are energy eigenstates. Measuring the atom’s energy gives one of these two allowed values.
Suppose the atom is prepared in the coherent state:
\[ |\psi\rangle= \frac{1}{\sqrt{2}} \left(|g\rangle+|e\rangle\right) \]
An energy measurement gives:
\[ P(g)=0.5 \]
\[ P(e)=0.5 \]
Now compare this with a classical mixture in which half the atoms are definitely in the ground state and half are definitely in the excited state.
An energy measurement produces exactly the same 50:50 distribution.
The two preparations are still different.
To reveal the difference, we need a measurement that tests the relative phase between the states rather than simply measuring their energies.
Measuring in a different basis
Define two new states:
\[ |+\rangle= \frac{|g\rangle+|e\rangle}{\sqrt{2}} \]
\[ |-\rangle= \frac{|g\rangle-|e\rangle}{\sqrt{2}} \]
These are different combinations of the original ground and excited states.
They form another measurement basis.
Notice that our coherent state is simply:
\[ |\psi\rangle=|+\rangle \]
Therefore, a perfect measurement in this new basis gives:
\[ P(+)=1 \]
\[ P(-)=0 \]
The result is completely predictable.
What happens for the classical mixture?
A ground-state atom has equal probabilities of producing the + and − outcomes. The same is true for an excited-state atom.
Since the mixture contains equal numbers of each:
\[ P(+)=P(-)=0.5 \]
We have finally found a measurement that distinguishes the two preparations.
This type of phase-sensitive measurement is related to Ramsey interferometry, a real technique used in atomic physics.
The first pulse prepares a superposition. The atom then evolves for a controlled time. A second pulse converts the accumulated relative phase into measurable changes in the ground-state and excited-state populations.
The underlying idea is the same as the two-path interferometer: two alternatives are prepared, allowed to accumulate a relative phase, and then recombined.
Wiseman and Milburn describe this two-level atomic method in Quantum Measurement and Control.
Coherent superposition versus classical mixture
The distinction is worth keeping in one place.
| Feature | Coherent superposition | Classical mixture |
|---|---|---|
| Preparation | One quantum state containing multiple amplitudes | An ensemble of definite states |
| Measurement in original basis | Can give 50:50 | Can give 50:50 |
| Relative phase | Well-defined | No stable relative phase |
| Measurement in another basis | Can reveal interference | No corresponding phase-dependent interference |
| Physical interpretation | Quantum alternatives combine coherently | Ordinary uncertainty about which state is present |
A coherent superposition does not mean that we are simply missing information about a definite classical state.
It also does not mean that a classical object has literally been divided into pieces.
It means that the quantum state contains multiple probability amplitudes whose relative phases can influence measurable outcomes.
04What happens to superposition over time?
There is another important connection to the stationary energy-level model.
An individual energy eigenstate is stationary. Its probability distribution does not change with time.
But a superposition of two different energy eigenstates is generally not stationary.
Why?
Because the two components evolve at different rates in phase.
Consider an atom initially prepared in:
\[ |\psi(0)\rangle= \frac{1}{\sqrt{2}} \left(|g\rangle+|e\rangle\right) \]
As time passes, the quantum state becomes:
\[ |\psi(t)\rangle= \frac{1}{\sqrt{2}} \left( e^{-iE_gt/\hbar}|g\rangle+ e^{-iE_et/\hbar}|e\rangle \right) \]
Here:
- \(t\) is the time elapsed, in seconds.
- \(E_g\) is the ground-state energy, in joules.
- \(E_e\) is the excited-state energy, in joules.
- \(\hbar\) is the reduced Planck constant, equal to \(h/(2\pi)\).
- \(i\) is the imaginary unit.
Each component gains a phase as time passes.
A phase multiplying the entire state has no observable effect. It is the difference between the phases that matters.
The relative phase develops according to:
\[ \phi(t)=\frac{\Delta E\,t}{\hbar} \]
where:
\[ \Delta E=E_e-E_g \]
The probability of measuring the atom in the + state is then:
\[ P(+)= \cos^2\left(\frac{\Delta E\,t}{2\hbar}\right) \]
This probability oscillates over time.
The period of a complete cycle is:
\[ T=\frac{2\pi\hbar}{\Delta E} \]
Since \(2\pi\hbar=h\):
\[ \boxed{T=\frac{h}{\Delta E}} \]
This gives a useful result: the larger the energy difference between the two states, the shorter the period of the phase-dependent oscillation.
Notice the subtle point.
The probability of measuring the atom in the ground state remains 50%, and the probability of measuring it in the excited state remains 50%.
Those energy probabilities do not change.
However, a measurement that is sensitive to the relative phase produces different results over time.
This is why a superposition of stationary energy states is generally not itself a stationary state.
Worked example: Calculating the phase evolution of an atom
An isolated two-level atom is prepared in an equal coherent superposition of its ground and excited states.
The energy difference between the states is \(2.0\ \mathrm{eV}\).
Calculate:
- The period of a complete relative-phase cycle.
- The probability of measuring the atom in the + state after one-quarter of this period.
- The probability of measuring the atom in the + state after half of this period.
Assume the atom remains perfectly coherent and experiences no external disturbance.
Step 1
We are given:
\[ \Delta E=2.0\ \mathrm{eV} \]
Using:
\[ 1\ \mathrm{eV}=1.60\times10^{-19}\ \mathrm{J} \]
Therefore:
\[ \Delta E=2.0\times1.60\times10^{-19} \]
\[ \Delta E=3.20\times10^{-19}\ \mathrm{J} \]
Step 2
The period of a complete phase cycle is:
\[ T=\frac{h}{\Delta E} \]
Substituting:
\[ T= \frac{6.63\times10^{-34}} {3.20\times10^{-19}} \]
\[ \boxed{T=2.07\times10^{-15}\ \mathrm{s}} \]
The relative phase completes one full cycle approximately every 2.07 femtoseconds.
Step 3
At \(t=T/4\), the relative phase is:
\[ \phi=\frac{2\pi}{4} =\frac{\pi}{2} \]
Using:
\[ P(+)=\cos^2\left(\frac{\phi}{2}\right) \]
We obtain:
\[ P(+)=\cos^2(45^\circ) \]
\[ \boxed{P(+)=0.50} \]
There is a 50% probability of measuring the atom in the + state.
Step 4
At \(t=T/2\):
\[ \phi=\frac{2\pi}{2}=\pi \]
Therefore:
\[ P(+)=\cos^2(90^\circ) \]
\[ \boxed{P(+)=0} \]
The atom is now certain to produce the − outcome in the ideal phase-sensitive measurement.
Step 5
At both times, the magnitudes of the ground-state and excited-state amplitudes remain unchanged.
Therefore:
\[ P(g)=P(e)=0.5 \]
The energy measurement still gives a 50:50 distribution.
The phase-sensitive measurement changes because the relative phase evolves, not because the probabilities of the two energy eigenstates change.
This distinction is central to understanding how quantum states evolve.
05What happens when the environment learns which state the system is in?
So far, we’ve assumed that the two alternatives remain coherent.
Real quantum systems interact with their surroundings. Those interactions can change the situation.
Return to the two-path photon experiment.
Imagine placing a device in each path that records which route the photon takes. The device acts as a path marker.
If the photon travels through L, the marker enters a state called \(|M_L\rangle\).
If the photon travels through R, it enters a state called \(|M_R\rangle\).
The combined photon-and-marker state can be written as:
\[ |\Psi\rangle= \frac{1}{\sqrt{2}} \left( |L\rangle|M_L\rangle+ |R\rangle|M_R\rangle \right) \]
The marker has become correlated with the photon.
This is an example of quantum entanglement: the combined system has a quantum state that links the possible states of its separate parts.
Now suppose the marker states are orthogonal.
In this context, orthogonal means that the marker states can be distinguished perfectly by an appropriate measurement.
The environment can now contain information about which path the photon followed.
When we ignore the marker and examine only the photon detections, the interference disappears.
Importantly, nobody needs to look at the marker. The physical interaction that stores distinguishable path information is enough.
This process is closely related to decoherence.
Decoherence occurs when interactions with the environment cause the relative phase information between alternatives to become unavailable in the system being observed.
The photon alone no longer displays the original interference pattern.
However, the combined photon-and-marker system can still be described by a coherent quantum state.
That distinction matters. Losing interference in the photon-only measurements does not necessarily mean that the combined system has become a classical mixture.
The quantum eraser
There is an even more interesting possibility.
Suppose the marker states are initially distinguishable, but instead of measuring the marker in the original \(|M_L\rangle\), \(|M_R\rangle\) basis, we measure it in a different basis:
\[ |M_+\rangle= \frac{|M_L\rangle+|M_R\rangle}{\sqrt{2}} \]
\[ |M_-\rangle= \frac{|M_L\rangle-|M_R\rangle}{\sqrt{2}} \]
This measurement does not reveal which path was taken.
Instead, it sorts the photon detections according to two different combinations of marker states.
The two groups can display complementary interference patterns.
When the groups are combined again, the interference disappears from the overall detection statistics.
This is the basis of the quantum eraser.
It does not mean that an experimenter changes the past or sends information backwards in time. The measurement reveals correlations that were already present in the combined quantum state.
The distinction between the total data and the selected subsets is essential. The raw photon counts do not regain interference simply because the marker is measured in a different basis.
Experiments demonstrating this principle include the quantum eraser experiment reported by Walborn and colleagues in Physical Review A in 2002.
06Questions and solutions
Question 1
An ideal balanced interferometer receives 1,000 photons, one at a time.
The relative phase between the two paths is fixed at \(0^\circ\), and the output beam splitter is calibrated so that this phase directs a coherent input towards detector D+.
Determine the expected number of detections at each output for:
(a) An equal coherent superposition of the two paths.
(b) An equal classical mixture of the two paths.
Explain why measuring the paths before recombination would not distinguish the two preparations.
Solution 1
(a) The coherent superposition produces 1,000 detections at D+ and none at D−.
The relative phase is zero, so:
\[ P(D_+)=\cos^2(0^\circ)=1 \]
\[ P(D_-)=\sin^2(0^\circ)=0 \]
Therefore:
\[ N_+=1000\times1=1000 \]
\[ N_-=1000\times0=0 \]
(b) The classical mixture produces 500 detections at each detector.
For an equal mixture, the probabilities of reaching either output are:
\[ P(D_+)=P(D_-)=0.5 \]
Therefore:
\[ N_+=1000\times0.5=500 \]
\[ N_-=1000\times0.5=500 \]
Why the two preparations differ:
Both preparations initially give a 50:50 distribution between paths L and R.
A path measurement therefore produces the same results for both.
However, the coherent superposition retains a relative phase, allowing its amplitudes to interfere when the paths are recombined. The classical mixture contains no corresponding phase relationship.
The tempting prediction is that equal path probabilities must produce equal output probabilities. That would be true if the alternatives were simply added as classical probabilities, but it ignores interference between coherent amplitudes.
Question 2
An atom has two energy eigenstates, \(|g\rangle\) and \(|e\rangle\).
It is prepared in one of two possible ways.
Preparation A: A coherent superposition:
\[ |\psi\rangle= \sqrt{\frac34}|g\rangle+ \sqrt{\frac14}|e\rangle \]
Preparation B: A classical mixture containing:
- 75% of atoms in \(|g\rangle\).
- 25% of atoms in \(|e\rangle\).
An ideal phase-sensitive analyser measures the atom in the basis:
\[ |+\rangle= \frac{|g\rangle+|e\rangle}{\sqrt2} \]
\[ |-\rangle= \frac{|g\rangle-|e\rangle}{\sqrt2} \]
Assume the relative phase in Preparation A is zero and there is no decoherence.
(a) What probabilities would an ordinary energy measurement produce for each preparation?
(b) Calculate the probabilities of measuring + and − for Preparation A.
(c) Calculate the probabilities of measuring + and − for Preparation B.
(d) Explain why the energy measurement cannot distinguish the preparations, but the phase-sensitive analyser can.
Solution 2
(a) Both preparations give 75% ground-state outcomes and 25% excited-state outcomes.
This follows directly from the squared magnitudes of the amplitudes in Preparation A and the stated populations in Preparation B.
For Preparation A:
\[ P(g)=\left|\sqrt{\frac34}\right|^2=0.75 \]
\[ P(e)=\left|\sqrt{\frac14}\right|^2=0.25 \]
Preparation B has exactly the same energy probabilities by definition.
(b) Preparation A gives approximately 93.3% + outcomes and 6.7% − outcomes.
First, rewrite the state:
\[ |\psi\rangle= \frac{\sqrt3}{2}|g\rangle+ \frac12|e\rangle \]
The probability amplitude for the + outcome is:
\[ A_+=\frac{1}{\sqrt2} \left(\frac{\sqrt3}{2}+\frac12\right) \]
Therefore:
\[ P(+)=|A_+|^2 \]
\[ P(+)=\frac{(\sqrt3+1)^2}{8} \]
\[ P(+)=\frac{2+\sqrt3}{4} \]
\[ \boxed{P(+)\approx0.933} \]
For the − outcome, the relative minus sign changes the amplitude:
\[ A_-=\frac{1}{\sqrt2} \left(\frac{\sqrt3}{2}-\frac12\right) \]
Therefore:
\[ P(-)=\frac{(\sqrt3-1)^2}{8} \]
\[ P(-)=\frac{2-\sqrt3}{4} \]
\[ \boxed{P(-)\approx0.067} \]
The two probabilities add to one, as required.
(c) Preparation B gives 50% + outcomes and 50% − outcomes.
For an atom definitely in the ground state:
\[ P(+|g)=P(-|g)=0.5 \]
The same is true for an atom definitely in the excited state:
\[ P(+|e)=P(-|e)=0.5 \]
Combining the two populations:
\[ P(+)=0.75(0.5)+0.25(0.5) \]
\[ \boxed{P(+)=0.5} \]
Similarly:
\[ \boxed{P(-)=0.5} \]
(d) The energy measurement only tests the original basis, whereas the phase-sensitive measurement tests the relationship between the amplitudes.
Both preparations have the same ground-state and excited-state probabilities.
However, the coherent preparation contains a definite relative phase. Its amplitudes combine constructively for + and destructively for −.
The classical mixture has no such phase relationship. Its probabilities are added instead.
This is the important distinction: identical probabilities in one measurement basis do not establish that two quantum preparations are physically equivalent.
Question 3
A photon source produces a combination of two types of preparation:
- A fraction \(q\) of the photons are in an equal coherent superposition with the same stable relative phase.
- The remaining fraction \(1-q\) are in an equal classical mixture of the two paths.
All photons pass through the same ideal balanced interferometer.
The following results are obtained:
| Relative phase | Fraction detected at D+ |
|---|---|
| \(0^\circ\) | 0.80 |
| \(180^\circ\) | 0.20 |
Assume the phase is controlled accurately and counting fluctuations are negligible.
(a) Determine the coherent fraction \(q\).
(b) Predict the fraction detected at D+ when the relative phase is \(60^\circ\).
(c) Predict the fraction detected at D+ when the relative phase is \(90^\circ\).
(d) Explain why obtaining a 50:50 output at one particular phase does not prove that the source produces a classical mixture.
Solution 3
(a) The coherent fraction is 60%.
The coherent fraction is:
\[ q=0.60 \]
To derive this, combine the contributions from both types of preparation.
For the coherent fraction:
\[ P_{\mathrm{coherent}}(D_+) =\cos^2\left(\frac{\phi}{2}\right) \]
For the mixture:
\[ P_{\mathrm{mixture}}(D_+)=0.5 \]
Therefore, the total probability is:
\[ P(D_+)=q\cos^2\left(\frac{\phi}{2}\right) +(1-q)\frac12 \]
At zero phase:
\[ 0.80=q(1)+(1-q)(0.5) \]
Expanding:
\[ 0.80=q+0.5-0.5q \]
\[ 0.30=0.5q \]
\[ \boxed{q=0.60} \]
We can check this using the second observation.
At \(180^\circ\):
\[ P(D_+)=(1-q)\frac12 \]
\[ P(D_+)=0.40\times0.50 \]
\[ P(D_+)=0.20 \]
This agrees with the supplied data.
(b) The fraction detected at D+ at \(60^\circ\) is 0.65, or 65%.
Substitute \(q=0.60\) and \(\phi=60^\circ\):
\[ P(D_+)=0.60\cos^2(30^\circ) +0.40(0.5) \]
Since:
\[ \cos^2(30^\circ)=0.75 \]
We obtain:
\[ P(D_+)=0.60(0.75)+0.20 \]
\[ \boxed{P(D_+)=0.65} \]
(c) The fraction detected at D+ at \(90^\circ\) is 0.50, or 50%.
Substituting:
\[ P(D_+)=0.60\cos^2(45^\circ) +0.40(0.5) \]
\[ P(D_+)=0.60(0.50)+0.20 \]
\[ \boxed{P(D_+)=0.50} \]
(d) A 50:50 result at one phase does not establish that the source is incoherent.
This is the important trap.
A completely coherent equal superposition also produces a 50:50 output when the relative phase is \(90^\circ\).
An equal classical mixture produces a 50:50 output at every phase.
Therefore, a single observation cannot distinguish these cases.
We need to vary the phase and examine how the output probabilities change.
The phase-dependent variation is called interference visibility. In this simplified preparation model, the coherent fraction determines the visibility.
The lesson is that coherence is not identified by whether one particular measurement gives unequal probabilities. It is identified by whether the probabilities respond to changes in relative phase.
Question 4
An isolated two-level atom is initially prepared in the coherent state:
\[ |\psi(0)\rangle= \frac{1}{\sqrt2} \left(|g\rangle+|e\rangle\right) \]
The energy difference between its excited and ground states is:
\[ \Delta E=1.5\ \mathrm{eV} \]
Assume the atom evolves freely, with no external disturbance or loss of coherence.
(a) Calculate the period of a complete relative-phase cycle.
(b) Determine the probability of measuring the atom in the + state after \(T/4\).
(c) Determine the probability of measuring the atom in the + state after \(T/2\).
(d) At both times, an ordinary energy measurement still gives equal probabilities of finding the atom in the ground and excited states. Explain how this is possible even though the quantum state has changed.
Solution 4
(a) The complete phase cycle takes approximately \(2.76\times10^{-15}\ \mathrm{s}\).
First, convert the energy difference into joules:
\[ \Delta E=1.5\times1.60\times10^{-19} \]
\[ \Delta E=2.40\times10^{-19}\ \mathrm{J} \]
The period is:
\[ T=\frac{h}{\Delta E} \]
Substituting:
\[ T=\frac{6.63\times10^{-34}} {2.40\times10^{-19}} \]
\[ \boxed{T=2.76\times10^{-15}\ \mathrm{s}} \]
(b) The probability of measuring + after \(T/4\) is 50%.
After one-quarter of a complete phase cycle:
\[ \phi=\frac{2\pi}{4}=\frac{\pi}{2} \]
The phase-sensitive probability is:
\[ P(+)=\cos^2\left(\frac{\phi}{2}\right) \]
Therefore:
\[ P(+)=\cos^2(45^\circ) \]
\[ \boxed{P(+)=0.50} \]
(c) The probability of measuring + after \(T/2\) is zero.
After half a cycle:
\[ \phi=\frac{2\pi}{2}=\pi \]
Therefore:
\[ P(+)=\cos^2(90^\circ) \]
\[ \boxed{P(+)=0} \]
The atom is certain to produce the − outcome in the ideal phase-sensitive measurement.
(d) The energy probabilities remain equal because the amplitudes change in phase, not magnitude.
The initial state has equal ground-state and excited-state amplitudes.
During free evolution, each amplitude acquires a phase factor:
\[ e^{-iE_gt/\hbar} \quad\text{and}\quad e^{-iE_et/\hbar} \]
These factors change the relative phase between the states but do not change the magnitudes of their coefficients.
Therefore:
\[ P(g)=P(e)=0.5 \]
at both times.
The tempting conclusion is that unchanged energy probabilities mean the quantum state has not changed.
That is incorrect because energy measurements do not reveal the relative phase.
A phase-sensitive measurement does reveal it, and therefore distinguishes the evolving states.
Question 5
A photon enters an ideal balanced interferometer and is prepared in an equal coherent superposition of two paths:
\[ |\psi\rangle= \frac{1}{\sqrt2} \left(|L\rangle+|R\rangle\right) \]
A path marker interacts with the photon.
If the photon travels along L, the marker enters state \(|M_L\rangle\). If it travels along R, the marker enters state \(|M_R\rangle\).
The resulting combined state is:
\[ |\Psi\rangle= \frac{1}{\sqrt2} \left( |L\rangle|M_L\rangle+ |R\rangle|M_R\rangle \right) \]
The marker states are orthogonal:
\[ \langle M_L|M_R\rangle=0 \]
This means they can be distinguished perfectly.
The photon then reaches the second beam splitter. The interferometer is calibrated so that:
\[ \frac{|L\rangle+|R\rangle}{\sqrt2} \longrightarrow D_+ \]
and:
\[ \frac{|L\rangle-|R\rangle}{\sqrt2} \longrightarrow D_- \]
Now consider two possible ways of reading the marker.
The first measures it in the original path basis, \(|M_L\rangle\) and \(|M_R\rangle\).
The second measures it in the alternative basis:
\[ |M_+\rangle= \frac{|M_L\rangle+|M_R\rangle}{\sqrt2} \]
\[ |M_-\rangle= \frac{|M_L\rangle-|M_R\rangle}{\sqrt2} \]
Answer the following:
(a) If we ignore the marker results and examine only the photon detections, what fraction of photons should reach D+ and D−?
(b) If the marker is measured in the \(M_+\), \(M_-\) basis, predict the photon detector outcome conditional on each marker result.
(c) Explain why measuring the marker in the alternative basis does not restore interference in the overall, unsorted photon data.
(d) Does this experiment show that the photon had a definite classical path before interacting with the marker? Explain your reasoning.
Solution 5
(a) The overall photon detection probabilities are 50% at D+ and 50% at D−.
The marker states are orthogonal, so the marker contains perfectly distinguishable information about the two paths.
When we ignore the marker and examine only the photon, the interference between the paths disappears.
The photon-only detection statistics are therefore equivalent to an equal mixture:
\[ P(D_+)=P(D_-)=0.5 \]
(b) Measuring the marker in the alternative basis produces perfect conditional correlations.
If the marker is measured in the \(M_+\), \(M_-\) basis, we can rewrite the combined state.
Starting with:
\[ |\Psi\rangle= \frac{1}{\sqrt2} \left( |L\rangle|M_L\rangle+ |R\rangle|M_R\rangle \right) \]
Using the definitions:
\[ |M_L\rangle= \frac{|M_+\rangle+|M_-\rangle}{\sqrt2} \]
\[ |M_R\rangle= \frac{|M_+\rangle-|M_-\rangle}{\sqrt2} \]
Substitute these into the original state:
\[ |\Psi\rangle= \frac12 \left[ (|L\rangle+|R\rangle)|M_+\rangle + (|L\rangle-|R\rangle)|M_-\rangle \right] \]
The first path combination exits through D+.
The second path combination exits through D−.
Therefore, the conditional results are:
| Marker measurement | Photon detector |
|---|---|
| \(M_+\) | D+ |
| \(M_-\) | D− |
Each marker outcome occurs with a probability of 50%.
(c) The overall photon data remain 50:50 because the two conditional groups have opposite outcomes.
This is the subtle part.
It is tempting to think that measuring the marker in a basis that does not reveal the original path should restore the original interference pattern in the complete photon dataset.
But the two marker outcomes are equally likely.
One group is correlated with D+, and the other is correlated with D−.
When we combine the groups without considering the marker results, their contributions produce equal detector probabilities.
The interference is visible in the conditional data, not in the unsorted photon counts.
This is precisely why the quantum eraser must be understood as a process involving correlations between two quantum systems.
(d) No, the experiment does not establish that the photon had a definite classical path before interacting with the marker.
The original photon state was a coherent superposition.
The interaction correlated each path alternative with a different marker state, producing an entangled photon-and-marker state.
The later measurement reveals different correlations depending on the basis used to read the marker.
It does not establish that the photon was secretly travelling along one definite classical path before the interaction.
The important constraint is that the marker and photon must be treated as one combined quantum system. Describing the photon alone loses information about the correlations between them.
This is a much deeper result than simply saying that observation changes an experiment.
It shows that the measurement basis, the information stored in the environment, and the correlations between systems all affect which interference patterns can be observed.
07Sources and further reading
The following university and primary sources support the atomic models, two-state quantum systems, and interference mechanisms discussed in this article.
- NSW Education Standards Authority – Physics 11-12 Syllabus (2025). The official syllabus and its modelling of the atom.
- MIT OpenCourseWare – Atomic Models: Rutherford & Bohr. An explanation of the classical and quantum assumptions in the Bohr model.
- Wiseman and Milburn – Quantum Measurement and Control. See Chapter 1, Box 1.4, for two-level atomic superposition and Ramsey interferometry.
- University of Arizona – Quantum Mechanics Lecture Notes. See the sections on two-level systems and statistical mixtures.
- Walborn et al. (2002) – Double-slit quantum eraser, Physical Review A. A primary research paper examining which-path information, entanglement, and quantum erasure.
08Where to go next
Quantum superposition provides the foundation for understanding quantum entanglement, where two or more systems become linked through their combined quantum state.
A particularly useful next step is Electron Spin: Intrinsic Angular Momentum Explained. Electron spin provides another two-state quantum system, and the same ideas of superposition, measurement basis, and phase become important when understanding atomic structure.
From there, Hyperfine Structure: How Nuclear and Electron Spins Split Atomic Levels shows how interactions between quantum states produce measurable changes in atomic energy levels.